TSshield E 04

download TSshield E 04

of 41

Transcript of TSshield E 04

  • 8/10/2019 TSshield E 04

    1/41

    TSshield

    Instruction manual

    21403 99274

  • 8/10/2019 TSshield E 04

    2/41

    i

    INTRODUCTION

    Thank you for purchasing our products.

    This product ("Product") has a capability of TSshield service ("TSshield service(s)"). (TSshield service offers both

    charged and uncharged services by using cellular phone connection. Please refer below for detail.)

    All of our customers who bought our product must register before using. These users have to understand some

    information that is related this product is collected automatically. This information is used for only supplying lager

    support service from Topcon.

    [User registration]

    Before using this product, the customer has to register to our service.

    All of the personal information that is registered at registration timing may be supplied to our subsidiaries and our

    business partners for only supplying TSshield service from these companies. At the anytime, these information

    MUST NOT be used for other purpose and these information also MUST NOT be supplied to another 3rd party.

    [What is TSshield?]

    TSshield services can offer various services both charged and uncharged based on collecting information from

    your Product. TSshield is a name of this service, and you can use the following services, but please note that we

    may expand or change our services at any time without any notice in advance to you.

    You can access to your dealer or read a product manual for the detailed information.

    - Viewing instrument information

    - Online upgrading*

    - Security lock/unlock by remote

    - Message receiving

    - Download Service of Software for the Products

    (including without limitation to, program files and language files)*

    * Any and all software provided under TSshield Service will be licensed only to you,

    and you must not sell, rent, lease, sublicense or otherwise dispose whole or part of the software.

    1. Collecting information

    (1) Kinds of information

    We collect information from you that is required to make user registration. We also collect information to

    provide you with the TSshield services through our server that automatically gathers information via cellular

    phone network from the product you use. The information we collect and maintain may include personal

    information about you, as well as following information which is planned to collect as of January 1, 2012:

    - Power up date/time

    - Power up location

    - Shut down date/time

    - Status/Error information

    Please note that, in the event of any change or expansion in the TSshield services, we may collect and

    maintain more information without any notice to you.

    If you have any questions regarding collection of information, please contact the dealer from whom you

    bought this Product or refer product manual.

    (2) Treatment of information

    We keep all of information from you in strict confidence, and limit access to the information to our direc-

    tors, officers and employees who need to know to provide you with the TSshield services. We maintain

    appropriate physical, electronic and procedural safeguards and controls to protect your information. Weuse ONLY for providing the TSshield service. We may share the information only with our affiliated com-

    panies to provide the TSshield services.

    We do not disclose your information to any third party for any reason, except:

    - Where such disclosure is required or appropriate pursuant to laws or regulations, including cooperating

    with governmental agencies, other regulatory bodies and law enforcement officials, resolving disputes

    or performing risk-management functions; or

    - Where such disclosure is required or appropriate to perform you with the TSshield services.

    (3) Stopping collecting information

    If you want to stop to be provided with the TSshield services, we will suspend collecting information and

    will retain and use your information only for compliance with regulatory requirements. If you resume being

    provided with the TSshield services, we will resume collecting information. ("resume process" may needs

    some additional works.) If you want to suspend and resume subscribing the TSshield services, pleasecontact dealer from whom you bought this Product.

    Note: While suspending, you can't use all of TSshield function at all.

  • 8/10/2019 TSshield E 04

    3/41

  • 8/10/2019 TSshield E 04

    4/41

    iii

    HOW TO READ THIS MANUAL

    About this instruction manual

    This instruction manual covers only the operating method of TSshield and setting menus of the instrument nec-

    essary when using TSshield.

    For safety precautions and instructions for use of the instrument and how to operate other modes, refer to the

    instruction manual of the your instrument.

    To use the service of TSshield, a web browser plug-in "Microsoft Silverlight" is necessary.

    Confirm that the PC, OS and web browser in use are compatible with the system requirements for Silverlight.

    For the details of Microsoft Silverlight, refer to its official website.

    Symbols

    The signs/marks as shown below are used in the instruction manual.

    Corporate and product names used in the instruction manual are the trademarks or registered trademarks of

    individual companies.

    Backing up data

    Data should be backed up (transfered to an external device etc.) on a regular basis to prevent data loss.

    Exceptions from responsibility

    The user of this product is expected to follow all operating instructions and make periodic checks (hardware only)

    of the products performance.

    The manufacturer, or its representatives, assumes no responsibility for results of faulty or intentional usage or

    misuse including any direct, indirect, consequential damage, or loss of profits.

    The manufacturer, or its representatives, assumes no responsibility for consequential damage, or loss of profitsdue to any natural disaster, (earthquake, storms, floods etc.), fire, accident, or an act of a third party and/or

    usage under unusual conditions.

    The manufacturer, or its representatives, assumes no responsibility for any damage (change of data, loss of

    data, loss of profits, an interruption of business etc.) caused by use of the product or an unusable product.

    The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused

    by usage different to that explained in the operators manual.

    The manufacturer, or its representatives, assumes no responsibility for damage caused by incorrect operation, or

    action resulting from connecting to other products.

    [CNFG] : Indicates softkeys of the instrument and buttons on a PC.

    {ESC} : Indicates operation keys on the instrument

    : Indicates screen titles

    : Indicates precautions and important information which should be readbefore operating the instrument

    : Indicates chapters (sections) which are relevant or should be referred to

    : Indicates supplementary notes

  • 8/10/2019 TSshield E 04

    5/41

    Contents

    iv

    1. TSSHIELDOVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.1 Mode Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

    2. USERREGISTRATIONANDLOGIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.1 New Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

    2.2 Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.3 Display and Change User Registration Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    3. DASHBOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103.1 Display Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    3.2 Display Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    3.3 Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    4. MANAGEMENTOFINSTRUMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134.1 Register Additional Instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    4.2 Display Instrument Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    4.3 Confirm Software Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    4.4 Confirm Instrument Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    4.5 Display Settings for Registered Instrument List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    5. SOFTWAREUPDATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205.1 Notice and Setting of Update Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    5.2 Wireless LAN Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    5.3 Perform Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

    5.4 Update Firmware Offline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    6. SECURITY FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .296.1 Set the Instrument to Lock Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    6.2 Set the Instrument to Chasing Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    6.3 Restore the instrument to Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

    7. WARNINGANDERRORMESSAGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33

    8. SPECIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

  • 8/10/2019 TSshield E 04

    6/41

    1

    1. TSshield OVERVIEW

    TSshield is a cloud-based information management service. It collects various information from your

    instrument and provides you with a range of support to ensure you can use the instrument safely.

    This allows us to send update information to you when the software embedded in your instrument is not

    up-to-date, and also allows you to see various information about your instrument purchased via your

    dedicated web site.

  • 8/10/2019 TSshield E 04

    7/41

    2

    1.1 Mode Sett ings

    Following are mode settings and key operations for shifting between modes of TSshield for this instru-

    ment.

    [ESC][Settings]

    [TSshield] [ESC]

    Settings mode

    P. 1

    P. 2

    ConfigObs.conditionInstr.config

    Comms setupUnit

    Instr.constChange PasswordDate and timeTSshield

    Key function

    Observation mode

    XX-103S/N 123456Ver. XXX-XX-XX XXX-XX-XXJob.JOB1

    rec 9999

    CNFGOBS USB DATA

    TSshield menu

    TSshield Update Settings

  • 8/10/2019 TSshield E 04

    8/41

    3

    2. USER REGISTRATION AND LOGIN

    It is necessary for you to register your TSshield to use the instrument you have purchased.

    2.1 New Registration

    If you are using TSshield for the first time, register your information and the instrument information.

    If you are already a registered user, you can put in the information of additional instruments.

    1. Go to the web site

    Connect to the following URL from your computer.

    https://tsshield.tierraservice.com/

    2. Start registration

    Press [New Registration].

    Language displayed during registration can be selected in "Language".

    Read the disclaimer on the Login screen before using this web site.

    Confirm the contents on the screen and press [Next].

  • 8/10/2019 TSshield E 04

    9/41

    4

    3. Enter registration information

    Enter your information and that of the instrument you have purchased.

    The model, serial number (S/N) and ID code are displayed when the instrument is turned on.

    Password Password should be at least 8 characters and can be up to 32 characters in length.

    Password should include both characters (alphabetic letters and symbols) and numbers.

    The same string of a whole e-mail address or former part of the address cannot be used for pass-

    word.

    User registration XX-103 S/N XXXXXX ID Code : XXXX-XXXX Unlock cd :

    OKCHECK DEMO

  • 8/10/2019 TSshield E 04

    10/41

    5

    4. Send registration information

    When you have finished entering the information, press [NEXT].

    A registration completion mail is sent to the email address you have registered.

    The registration completion mail contains your customer code and the password for login. Securely

    store it.

    As an e-mail containing the verification code is sent from [email protected], if you have set

    the restriction on receiving e-mails, change the restriction setting.

    5. Obtain the unlock code

    Enter on the web page your customer code provided in the registration completion mail, and press

    [NEXT].

    The unlock code is displayed on the screen, and an e-mail including the unlock code is sent to you.

  • 8/10/2019 TSshield E 04

    11/41

    6

    6. Certify the license

    Deactivate the demo mode.

    Certifying the license can be done either by communicating the unlock code to the server through the

    instrument or by entering the unlock code in the instrument.

    If you are in a place with poor signal quality, enter the unlock code in the instrument to certify yourlicense.

    (1) When certifying your license through communication with

    the server

    Turn on the instrument.

    Press [CHECK]on the User Registration Screen.

    When your registered information has been confirmed with

    the server, the demo mode is deactivated.

    It may take a maxi-mum of 10 min depending on the recep-

    tion condition. If registration does not complete 10 min after,

    reception condition may be bad.

    (2) When certifying your registration by entering the unlock

    code

    Turn on the instrument.

    Enter the unlock code in the instrument and press [OK].

    When the correct unlock code has been entered, the demo

    mode is deactivated.

    User registration XX-103 S/N XXXXXX ID Code : XXXX-XXXX Unlock cd :

    OKCHECK DEMO

    User registration

    OK

    Complete.

    User registration XX-103 S/N XXXXXX ID Code : XXXX-XXXX Unlock cd :

    OKCHECK

    DEMO

    1 2 3 4 5 6 7 8

    User registration

    Complete.

    OK

  • 8/10/2019 TSshield E 04

    12/41

    7

    2.2 Login

    1. Access the web site

    Access to the following URL via a PC.

    https://tsshield.tierraservice.com/

    2. Login

    Enter the registered e-mail address and password, select the brand of the instrument for which you

    wish to display information, and then press [Login].

    To log in for the first time, user registration for TSshield is required. It is necessary to press [New

    Registration]on the Login screen to register your information and product information.

    "2.1 New Registration"

    Language displayed in the login screen can be selected in "Language".

    2.2.1 If you forget your password

    If you forget your password for login, you can change it with the following procedures.

    1. Display

    Press [Forgot your password?]on the Login screen.

  • 8/10/2019 TSshield E 04

    13/41

    8

    2. Input registration information

    Check either E-Mail or User code (Customer Code). Then enter the registration information of

    checked item.

    Pressing [OK] issues a verification code to the registered e-mail address. At the same time, the

    screen is displayed.

    Your customer code is included in the registration confirmation mail sent to you after user registration.

    As an e-mail containing the verification code is sent from [email protected], if you have setthe restriction on receiving e-mails, change the restriction setting.

    If you already have a verification code, click the link "If you have verification code, please click this

    link." to go to step 3.

    3. Set the password

    Enter the verification code contained in the e-mail, and enter a new password. Then enter the new

    password once again, and press [OK].

    Enter the new password to log in on the Login screen.

    If you have got some verification codes, use the latest code. Password rules: "Password"(p.4)

  • 8/10/2019 TSshield E 04

    14/41

    9

    2.3 Display and Change User Registration Information

    Registered user information can be confirmed and changed through the following procedure.

    1. Display MY WEB USER PROFILE

    Select MY WEB USER PROFILE from Administration.Then, your registered information is displayed.

    2. Change the contents of registration

    Make necessary changes to the information and press [Apply].

    The information will be updated next time you log in.

    Language displayed on TSshield can be changed in "Language".

    Password rules: "Password"(p.4)

  • 8/10/2019 TSshield E 04

    15/41

    10

    3. DASHBOARD

    When you log in TSshield, the Dashboard screen is displayed.

    On the Dashboard screen, it is possible to display the location of and information on the instrument by

    switching between the Map and List tabs.

    To display information on a specific date, select the date on the calendar, and press [Refresh] to update

    the information. The currently selected date is displayed in [Current date].

    Pressing [Dashboard] on any screen always returns to the Dashboard screen.

  • 8/10/2019 TSshield E 04

    16/41

    11

    3.1 Display Map

    View controller:

    Click any of the direction buttons to move in the relevant direction on the map. You can zoom in/out the

    location on the map using a slider.

    Display format:

    Switch the display format between the road map (Road) and aerial photo (Aerial).

    Overlaying the mouse cursor on an icon will display the detailed information on the instrument.

    The position where the instrument conducted communication last on the selected day is indicated as

    an icon.

    Immediately after login, the information on the day before the login date is displayed.

    Changing display format

    Direction button

    Slider

    View controller

    Road map Aerial photo

  • 8/10/2019 TSshield E 04

    17/41

    12

    3.2 Display Lists

    Display the list of information on the instrument.

    Clicking an item sorts data using the item as a sort key.

    3.3 Fi l ter

    Display the instrument selected based on the specified condition on the Dashboard.

    It is possible to combine multiple conditions.

    Search condition

    The model and serial number of the instrument

    Mode settings of the instrument

    Set the conditions and press [OK].

    Pressing [Clear]deletes all the set conditions.

  • 8/10/2019 TSshield E 04

    18/41

    13

    4. MANAGEMENT OF INSTRUMENT

    The screen displays the list for the registered instruments (products). You can get the

    information of an instrument to confirm its conditions or change its instrument setting.

    4.1 Register Addit ional Instruments

    If you are already a registered user, you can put in the information of additional instruments.

    1. Login to TSshield

    "2.2 Login"

    2. Display Instrument Info

    Select Instrument Info from Administration.

    3. Start registration

    Press [New registration]to display the window shown below.

  • 8/10/2019 TSshield E 04

    19/41

    14

    4. Enter registration information

    Enter the information of the instrument you have purchased.

    The model, serial number (S/N) and ID code are displayed when the instrument is turned on.

    5. Send registration informationWhen you have finished entering the information, press [OK].

    The unlock code is displayed on the screen, and an email containing the unlock code is sent to you.

    6. Certify license

    See Step 6 in "2.1 New Registration"

    4.2 Display Instrument Information

    Log in to TSshield.

    A list of registered instruments is displayed at the left side of the screen.

    Registered Instrument List

  • 8/10/2019 TSshield E 04

    20/41

    15

    You can select any of the registered instruments to display its information.

    "4.5 Display Settings for Registered Instrument List"

    Tick the checkbox for the instrument on which you wish to obtain information and press [Get info].

    The instrument information is displayed as a list.

    Pressing [Select All] ticks checkmarks for all the registered instruments. Pressing [Select None]

    clears all the checkmarks.

    Select any instrument from the Instrument Info List to display its detailed information.

    Instrument Info List

    Detailed information

  • 8/10/2019 TSshield E 04

    21/41

    16

    4.3 Confirm Software Version

    The software version of the instrument selected in the Instrument Info List can be confirmed.

    Confirmation of version

    Press [Current]to display the installed version and the latest version available for each software.

    Updating software: "5. Software Update"

    Confirmation of installation history

    Press [History]to display the history of the version for each software installed in the instrument.

    4.4 Confirm Instrument Sett ings

    Instrument settings for the instrument selected in the Instrument Info List can be confirmed.

    Changing the setting: "6. SECURITY FUNCTION"

  • 8/10/2019 TSshield E 04

    22/41

    17

    4.5 Display Sett ings for Registered Instrument List

    You can designate the instruments to be displayed in the Registered Instrument List.

    Search for an instrument meeting the conditions and add the instrument to the List. Also, you can

    delete an instrument which is registered in the List.

    1. Search instrument

    Press [Instrument Selector]to display screen.

    Enter search criteria in Search Parameters, and press [Search]to display a search result.

    Setting search criteria: " 4.5.1 Searching instrument"

  • 8/10/2019 TSshield E 04

    23/41

  • 8/10/2019 TSshield E 04

    24/41

    19

    Pressing [Save as Default]specifies that the currently displayed instrument to be displayed immedi-

    ately after login.

    Press [Restore Default]to regain initial settings.

    4.5.1 Searching instrument

    Pressing [Search]without setting any parameters displays all the instruments registered by users in

    Search results.

    Search by limiting range of serial number

    (1) Check S/N.

    (2) Select Assign number to set the range of serial numbers.

    Enter the starting number in the left field and the ending number in the right field.

    (3) Press [Search]to display instruments with matching serial numbers in Search results.

    Search by characters contained in serial number

    (1) Check S/N.

    (2) Select Search match and enter a search word in the field.

    (3) Set the search criteria.

    Forward match: Instrument with the serial number starting with the search wordBackward match: Instrument with the serial number ending with the search word

    Partial match: Instrument with the serial number containing the search word

    (4) Pushing [Search]displays instruments with matching serial numbers in Search results.

  • 8/10/2019 TSshield E 04

    25/41

    20

    5. SOFTWARE UPDATE

    TSshield automatically connects to the network to check if any software in the total station needs updat-

    ing and, when necessary, downloads programs to update the software.

    When a new software is registered to the network, a message will be displayed when the total station is

    turned on.

    In order to update the software, you need to have Wireless LAN (WLAN) Internet access connected

    by home broadband and have your total station set for Wireless LAN.

    Forward port number 21 and number 7000, and set FTP to passive mode in advance.

    For the setting procedure, refer to the instruction manuals of your modem or router, or ask theirmanufacturer.

    In case of restricting some access points on the network using filter etc., contact your local dealer.

    Update may take 10 to 60 min depending on the number of files to update, reception condition and

    Wireless LAN connection condition.

    You can install the firmware of the instrument offline by downloading its installer from the web site.

    "5.4 Update Firmware Offline"

    5.1 Notice and Sett ing of Update Information

    When the total station is turned on, it checks if there is any software update information. When there is,

    the following screen is displayed. Press [OK]to perform normal update.

    You can change how often you want to confirm update information in the Settings.

    Procedure

    1. Enter the TSshield menu

    Select in the settings mode.

    2. Select

    Update

    Update is detectedSelect update menuor use USB memory

    OK

    Update

    Update is detectedSelect update menuor use USB memory

    OK

    TSshield Update Settings

  • 8/10/2019 TSshield E 04

    26/41

    21

    3. Select

    is displayed.

    4. Change notice period

    Select a notice period by pressing [

    ] / [

    ].

    Press [ENT]to complete the change and return to .

    Choices available for update notice period: Always / Every day / Every week / No

    5.2 Wireless LAN Sett ings

    Procedure

    1. Enter the TSshield menu

    Select in the settings mode.

    2. Select .

    3. Select

    is displayed.

    4. Search for access points

    Press [SRCH] to start searching for Wireless LAN access

    points in your area.

    Press [STOP]to stop searching.

    Go to Step 6 to directly input setting details.

    Update settings WLAN settings

    Update settings Notice:Always

    Change PasswordDate and timeTSshield

    Key function

    TSshield Update Settings

    Update settings WLANsettings

    AP

    Searching...

    STOP

    WLAN settingsSSID:1Security type:WPAPassword:DHCP:OFF

    OKSRCH

  • 8/10/2019 TSshield E 04

    27/41

    22

    5. Select an access point

    When searching is complete, a list of obtained access points

    is displayed. Select an access point and press [OK], then

    you are redirected to .

    6. Input a password

    Input a password (encrypt key) for a wireless LAN.

    Press [Shift] to select the character input mode (alpha-

    bets/numeric).

    Do the detailed settings when necessary. The items you

    can set are as follows:

    SSID (Maximum size is 31)

    Security type

    Password (Maximum size is 31) DHCP

    IP adress (IP)

    Subnet mask (SUB)

    Default gateway (GW)

    DNS server (DNS)

    Move the cursor to each item and press [ENT]to display

    the input screen. Enter setting contents and press

    [ENT].

    Some items may not be displayed depending on the

    contents of settings.

    For the contents of settings, refer to the instruction man-

    ual of your Wireless LAN terminal.

    7. Finish the settings

    Press [OK] to finish Wireless LAN settings and return to

    .

    AP List SIG SEC123-LAN-XXX 5 OPENWT-100-XXXX 6 OPENABD-XXX-NET 5 WPA8XE-LAN-XXX 5 WPA

    OK

    WLAN settingsSSID:ABD-XXX-NETSecurity type:WPAPassword: * * * * * *DHCP:OFF

    OKSRCH

    WLAN settingsIP:192.168.0.70SUB:255.255.255.0GW:192.169.0.2DNS:192.169.0.20

    OKSRCH

  • 8/10/2019 TSshield E 04

    28/41

    23

    5.3 Perform Update

    Make sure to use the provided battery and there is enough battery left before performing update.

    The update should be done where wireless LAN connection is in good condition.

    Do not remove the battery during the update. Do not also disconnect the wireless LAN. Installed pro-gram will be damaged, and the total station might not operate collect. Disconnected wireless LAN

    might need some time for reconnection.

    Instrument Info on the TSshied web page is renewed after 24 hours.

    Procedure

    1. Enter the TSshield menu

    Select in the settings mode.

    2. Select

    The total station checks with the server for update informa-

    tion.

    When the latest software is already installed, a screen

    shown in the right is displayed.

    When a screen shown in the right is displayed, press any

    key to to cancel the update.

    Retry the update where wireless LAN connection is in good

    condition or check the password for WLAN setting.

    TSshield Update Settings

    Update

    Connecting...

    Update

    Server checking... Searching...

    Update

    The S/W is current

    O K

    Update

    Stopping

    Press any key

  • 8/10/2019 TSshield E 04

    29/41

    24

    3. Perform update

    When there is updatable software, a screen shown in the

    right is displayed. Then, press [OK].

    A screen shown in the right is displayed. Then, press [YES].

    (Update time depends on the connection condition).

    When application update is included, the total station will

    restart automatically after completing the update. Press [YES]

    to perform update.

    After the screen shown in the right is displayed, the update

    program starts to be downloaded. The message flashesduring the download.

    Press {ESC}to cancel the download.

    Canceling may take some time. Do not remove the bat-

    tery while canceling is in progress.

    When wireless LAN connection is not in good condition, a

    screen shown in the right is displayed. Press any key to

    return to step 2.

    Retry the update where wireless LAN connection is in good

    condition.

    When the program download is completed, the message

    turns to be lit, and then software update starts automati-

    cally. It takes about 10 min before update completion.

    4. Finish update

    When update is complete, press [OK]to return to .

    When an application has been updated, the total station

    restarts.

    Update list

    EDM X-X.XXxDCPU X-X.XXxTS_COMM

    OK

    Ready for update?

    YESNO

    Update

    Appl icat ionDownloding...

    Do not remove BATT.

    StoppingWLAN was lost.

    Press any key

    Update

    Appl icat ionUpdating...

    Do not remove BATT.

    Update

    Complete.

    OK

  • 8/10/2019 TSshield E 04

    30/41

    25

    5.4 Update Firmware Offl ine

    It is possible to update the firmware offline by connecting a USB memory storing the firmware installer

    to the total station. The installer can be downloaded from the TSshield web site.

    When updating the firmware, attach a fully charged battery to the total station or use the exter-

    nal power source adapter (special accessory). When updating, use a blank USB memory.

    Notice of update information, that is displayed turn on the total station, does not displayed the

    day after the software update. Instrument Info of the TSshied is also renewed on the day after

    the software update.

    5.4.1 Download the update file

    1. Download the update file

    Download the update file (*.sbc) from the TSshield web site.

    (1) Select the instrument to update in the Instrument Information.

    Press [Download]in the Software Version.

    (2) Click the link for the file to download in the window below.

    Follow the instructions on the screen to download the file.

    Input the file name in the following Save As screen refiring the displayed file name in step (2).

  • 8/10/2019 TSshield E 04

    31/41

    26

    Depending on your PC environment, extensions may not be displayed.

    2. Save the update file to a USB memory

    Save the downloaded update file in the root folder of a USB

    memory.

    5.4.2 Perform update (DCPU/EDM)

    1. Boot up the total station in update modePress the following keys depending on the firmware to

    update.

    DCPU: Press the power switch pressing {F1}and {ENT}.

    EDM: Press the power switch pressing {F3}and {ENT}.

    2. Execute update

    (1) Confirm in the right screen that update is executed via

    USB memory.

    If serial connector is selected, press [USB] to change

    the setting.

    (2) Select Firmware download.

    Wait until

    D o w n l o a d p r o g r a m

    P r e s s E N T t o s t a r tU SB m em or y .

    VerCOM sum

    D o w n l o a d p r o g r a m

    P r e s s E N T t o s t a r t( 1 1 5 2 0 0 b p s )

    VerUSB sum

    (via USB memory)

    (via serial connector)

  • 8/10/2019 TSshield E 04

    32/41

    27

    (3) Select the file to use for update. Press [NEXT] to display

    the next file. Press [OK]to decide the file.

    (4) Press [DL]to start update.

    Data in flash memory is cleared, then the new program

    is written on.

    3. Exit update

    When update is completed, the total station automatically

    restarts.

    5.4.3 Perform update (TS_COMM)

    1. Boot up the total station in update mode

    Press the power switch pressing {F4}and {ENT}.

    2. Execute update

    (1) Insert the USB memory to the USB port.

    (2) Select Firmware download.Leave the instrument until waiting time becomes 0 then

    the next screen is displayed.

    U SB L o ad er V 1 - X . X X

    1 - x 2 1 A S ( x x x x )

    F i l e S e l e c t 1

    2 0 X X / 0 8 / 3 1 1 2 : 0 0 : 0 0NEXTOK

    file name

    U SB L oa d er V 1 - X . X XF i l e S e l e c t 1

    1 - x 2 1 A S ( x x x x )V e r . : 1 - x . 2 1 A S

    NEXTDL

    U S B L o a d e r F l a s h E r a s e

    V e r . : 1 - x . 2 1 A S

    U S B L o a d e r F l a s h W r P r o g r e s s

    V e r . : 1 - x . 2 1 A S

    T S _ C O M M D o w n l o a d

    F i r m w a r e d o w n l o a d

    T S _ C O M M < - - - > P C F i r m w a r e v e r s i o n

    T S _ C O M M O N P l e a s e w a i t . . . 0 9

  • 8/10/2019 TSshield E 04

    33/41

    28

    (3) Select the file to use for update. Press [NEXT] to display

    the next file. Press [OK]to decide the file.

    (4) Press [DL]to start update.

    Data in flash memory is cleared, then the new program

    is written on.

    3. Exit update

    When update is completed, is

    restored.

    file name

    U S B T S _ C O M M

    W K T S O M M x x x

    F i l e S e l e c t 1

    2 0 X X / 0 8 / 3 1 1 2 : 0 0 : 0 0NEXTOK

    U S B T S _ C O M MF i l e S e l e c t 1

    W K T S O M M x x xV e r . : 1 . x . x . x

    NEXTDL

    U S B T S _ C O M M

    D o w n l o a d i n g . . .

    V e r . : 1 . x . x . x

    U S B T S _ C O M MP a r a m e t e r C h e c k

    V e r s i o n C h e c k

    D o w n l o a d C o m p l e t e

    O K

  • 8/10/2019 TSshield E 04

    34/41

    29

    6.SECURITY FUNCTION

    TSshield has security functions: lock mode and chasing mode.

    In lock mode, it is possible to lock the instrument which is mislaid or lost by remote control on its

    web site. It prevents the instrument to be used without the owner's permission.

    In chasing mode, location information of the instrument on the Dashboard screen is renewed more

    frequently and it helps the instrument to be found.

    6.1 Set the Instrument to Lock Mode

    1. Read in the instrument information

    When you log in TSshield web site, the list of registered instruments is displayed.

  • 8/10/2019 TSshield E 04

    35/41

    30

    Check the box of the instrument you want to lock in "Instrument Info", then press [Get info]to read in

    the instrument information.

    2. Display the detailed instrument information

    Highlight the instrument to display it's detailed information.

  • 8/10/2019 TSshield E 04

    36/41

    31

    3. Change the settings

    Press [Set] in "Instruments Settings" in the screen of step 1 to display .

    Select "Lock" in "Settings" and select an item in "Reason". Press [OK] to complete the instrument

    setting.

    The the instrument will be locked when it is connected to

    the server for the first time after the instrument setting.

    Other than Power OFF, all the operation is invalid for the

    locked instrument.

    To unlock the instrument, it is necessary to restore the

    instrument to normal mode on the web site.

    "6.3 Restore the instrument to Normal Mode"

    6.2 Set the Instrument to Chasing Mode

    1. Display the detailed instrument information

    "6.1 Set the Instrument to Lock Mode"step1 to 2

    2. Change the settings

    Press [Set]in "Instruments Settings" in the screen to display . Select "Chas-

    ing" in "Settings" and select an item in "Reason". Press [OK]to complete the instrument setting.

    TSsh ie ld

    L o c k e d b y T S s h i e l d

  • 8/10/2019 TSshield E 04

    37/41

    32

    Location information of the instrument is renewed as follows.

    Normal mode :24 hours

    Chasing mode:1 hour

    To unlock chasing mode, it is necessary to restore the instrument to normal mode on the website.

    "6.3 Restore the instrument to Normal Mode"

    The instrument consumes more energy in chasing mode than in normal mode.

    6.3 Restore the instrument to Normal Mode

    1. Display the detailed instrument information

    "6.1 Set the Instrument to Lock Mode"step 1 to 2

    2. Change the settings

    Press [Set]in "Instruments Settings" to display .

    Select "Normal" in "Settings".

    Press [OK]to complete the setting.

    The instrument will be returned to normal mode when it is rebooted.

  • 8/10/2019 TSshield E 04

    38/41

    33

    7. WARNING AND ERROR MESSAGES

    The following is a list of the error messages displayed by the instrument and the meaning of each mes-

    sage.

    E:880: Contact Dealer.

    A problem has occurred with TSshield and operation stops.

    Power the instrument OFF then ON to reboot. The instrument can be operated temporarily with TSshield dis-abled.

    If this error message appears, contact your local dealer.

    Please communicate with server.

    The instrument and TSshield server have not been connected for a long periods of time.

    TSshield uses the same frequency band with that of cellular phones.

    Set up the instrument where connection for cellular phones is in good condition, then leave it for 10 -15 min-

    utes with power ON. Measurement can be performed even during connection.

    If this error message appears frequently, contact your local dealer.

    Errors during update

    Error codes may be displayed during update. Meanings of the error codes are as follows.

    000C

    Access point can not be found.

    Check if the set SSID is correct.Retry a connection where Wireless LAN connection is in good condition.

    0011

    Connection between the access point failed.

    Retry a connection after some time.

    0012

    Connection to the network failed. (DNS error)

    Check if IEE802.11n is not selected as communication option.

    E880 : Contact Dealer Not serious error for field work You can use inst. temporarily Plese Power off

    E880 : Contact Dealer

    Expiry: 13days Work temporary

    OK

    When the error occurs After the reboot

    Update

    Stopping 003-00000013

    Press any key

    Error codes (last four (4) digits)

  • 8/10/2019 TSshield E 04

    39/41

    34

    0013

    The password you entered is different from the set password.

    Check if the input password is correct.

    0021

    Connection to the network failed.

    Check if network port No.21 is open.

    0027

    Connection to the network failed.

    Check if network port No.7000 is open.

    Power the Wireless LAN devices(router and access point) OFF then ON to reboot, then retry the

    connection.

    F025

    Connection is not established in the allotted time.

    Retry a connection after some time.

  • 8/10/2019 TSshield E 04

    40/41

    35

    8. SPECIFICATION

    The specifications specific to this instrument are as follows.

    For other specifications, see your instrument Operators manual.

    Wireless LAN function

    Support format: IEEE802.11b/g

    Security WPA/WPA-PSK/WPA2, WEP 128/64bit

    Frequency band 2.4GHz

    Cellular module function

    Transmission method 2G: GSM (850/900/1800/1900MHz)

    3G: UMTS/HSDPA (WCDMA) (850/1900/2100MHz)

  • 8/10/2019 TSshield E 04

    41/41

    http://www.topcon.co.jp

    Pl th tt h d dd li t th f ll i b it f t t dd