TSA-200TM - Telefire · TSA-200 Control Panel Telefire’s new generation conventional control...

2
Complies with all major international standards: UL-864, EN-54, EN-12094, GOST, IS 1220, CE TSA-200 TM Conventional Two-Zone Fire Alarm and Extinguishing Control Panel Maintenance Alarm — Includes a maintenance notification for detectors (dependant on using Telefire detectors), a function that required, until now analog addressable panels Modularity — Base system can be expanded via an optional extinguishing module Internet ready — Opt onal module adds monitoring and notification capabilities (Web Server / E-mail notification / SMS paging (texting) / Fire alarm monitoring via LAN, WAN, or Internet Programmability — All parameters entered from front panel (does not require a PC) Protected Access — Password-protected authorized access Installer Friendly — Easy operation and maintenance High Survivability — Telefire’s unique ACM (Advanced Current Management) provides high resilience during abnormal conditions Industrial EMC approved

Transcript of TSA-200TM - Telefire · TSA-200 Control Panel Telefire’s new generation conventional control...

Page 1: TSA-200TM - Telefire · TSA-200 Control Panel Telefire’s new generation conventional control panel narrows the gap between analog addressable and conventional control panels. Drawing

Complies with all major international standards: UL-864, EN-54, EN-12094, GOST, IS 1220, CE

TSA-200TM

Conventional Two-Zone Fire Alarm andExtinguishing Control Panel

■ Maintenance Alarm — Includes a maintenance notification for detectors (dependant on using Telefire detectors), a function that required, until now analog addressable panels

■ Modularity — Base system can be expanded via an optional extinguishing module

■ Internet ready — Opt onal module adds monitoring and notification capabilities (Web Server / E-mail notification / SMS paging (texting) / Fire alarm monitoring via LAN, WAN, or Internet

■ Programmability — All parameters entered from front panel (does not require a PC)

■ Protected Access — Password-protected authorized access

■ Installer Friendly — Easy operation and maintenance

■ High Survivability — Telefire’s unique ACM (Advanced Current Management) provides high resilience during abnormal conditions

■ Industrial EMC approved

Page 2: TSA-200TM - Telefire · TSA-200 Control Panel Telefire’s new generation conventional control panel narrows the gap between analog addressable and conventional control panels. Drawing

TSA-200 Control Panel

Telefire’s new generation conventional control panel narrows the gap between analog addressable and conventional control panels. Drawing on more than three decades, experience in designing fire alarm control panels, the state of the art TSA-200 Conventional Two-Zone Fire Alarm and Extinguishing Control Panel was designed and operates in compliance with numerous standards, amongst which are EN 54-2; EN 54-4; EN 12094-1; UL 864; GOST; CP 10; and IS 1220.

The control panel is available in two models:■ TSA-200 – a two zone fire alarm control panel■ TSA-200X – a two-zone fire alarm and

extinguishing panel

The TSA-200 is ideally suited for new and retrofit applications. The base control panel includes two

detection zones, horn output, dialer output, an alarm and a fault relay, and two open-collector outputs that can activate a notification LED or a relay.

The TSA-200X, with the addition of an optional extinguishing module adds an extinguishing output, an “extinguishing activated” output, and three inputs, for extinguishing abort, extinguishing activation, and pressure switch input. The system includes a maintenance alert for detectors (dependant on using Telefire detectors), a function that required, until now, analog addressable panels.

Walk test mode allows detector testing using only one technician, whilst differentiating between activations that are done for testing purposes and real alarms. The system includes an automatic alarm verification feature to increase reliability.

A typical system

Dimensions 325 / 245 / 90 mm (W/H/D)

Operating Temperature Range -10°C – +60°C (14°F – 140°F)

Operating Voltage 230 Vac +10/-15% 50/60 Hz

24Vdc Output 1.0A

Specification

Zone 1

Zone 2

Abort

Alarm Sounder

Zone 1Alarm Out

Zone 2

Alarm RelayFault Relay

Telephone Dialer TDM-500i

ExtinguisherActivated

Extinguisher

Pressure Switch

Manual Activate

P.O.B. 7036, Petach Tikva 49250, IsraelTel: +972 3 970 0400Fax: +972 3 921 1816Email: [email protected]