TS-324 Panel Guide - Welcome to Triad Corrugated · PDF fileTS-324 Panel Guide TRIAD...
Transcript of TS-324 Panel Guide - Welcome to Triad Corrugated · PDF fileTS-324 Panel Guide TRIAD...
C O M M E R C I A L | R E S I D E N T I A L | A G R I C U L T U R A L
TS-324 Panel Guide
TRIAD CORRUGATED METAL, INC.
The TS-324 Roof System is a heavy-duty structural roof system designed for use where water penetration resistance, expansion / contraction control, and load capacity are of prime importance.The Triad Corrugated Metal TS-324 is designed to have superior wind and water resistance, flexibility of application, and long lifespan for commercial and industrial roof instal-lations. Three levels of uplift resistance are available with Single-Lok, Double-Lok, or Triple-Lok seaming.
General Information 1
TS-324 Panel Description & Summary Test Data 2
Eave Section - Eave Gutter 3
Eave Gutter - ISO View 4
Eave Section - High Eave Trim 5
High Endwall Section - Transition Flashing 6
Ridge Section 7
Ridge - ISO View 8
Starting Rake Section - Rake Trim 9
Valley Section 10
Table of Contents
For additional information call Triad Corrugated Metal. (336) 625-9727 | www.triadmetalroof.com1 REV01.10
• Finishes: Classic Sil-Poly & Premium Kynar • Metals: Galvanized, Galvalume® and Aluminum• Gauges: 26ga, 24ga & 22ga• Features : ∆ Applies over open framing or solid substrate ∆ Lengths cut to the inch ∆ Minimum roof slope: 1/4:12 ∆ Self ventilating
36
ACCESSORIES
Number in circles refer to page numbers in TCM Metal Roofing Guide.
The TS-324 Trapezoidal SSR System with the Double-Lok seam is installed with the recom-mended anchor clip, then the panels are snapped together and hand seamed at each clip loca-tion, providing added separation and uplift resistance. The Triple-Lok seam is made by running a power seamer over the Double-Lok, forming a tight seam the full length of the panel. The Triple-Lok seam becomes more tightly engaged as the panel is subjected to wind uplift loads. Where maximum wind load resistance is called for, the Quad-Lok seam is formed by using the power seamer to provide an additional fold to the Triple-Lok for the full panel length.
TS-324
3”2”
24”
Female Seam Male Seam
32
31
31
31 32
3131
Roof Structural
2"
11
"2
Male�Corrugation
"43
FemaleCorrugation
or1
Stan
doff
Seam Sealant�(factory applied inside seam)
Sidelap Section
Panel ClipTa b
Base
FastenerPanel Clip
Panel Clip
TripleLok Fully seamed from end to end
Panel Clip
Panel Clip
Roof Structural
2"
11
"2
Fastener
Male FemaleCorrugation
or1
Stan
doff
Base
TabPanel Clip
Corrugation
Sidelap Section
(factory appliedSeam Sealant
inside seam)
QuadLok Adds final 90° bend
DoubleLok Crimp seamed at clips only
For additional information call Triad Corrugated Metal. (336) 625-9727 | www.triadmetalroof.com 2REV01.10
TS-324Panel Description
& Summary Test Data
Underwriters Labratories Inc. Construction # 552, 552A, 552B. UL 580/UL1897 test.Factory Mutual 4471 Uplift Test ASTM E 1592 Uplift Test
AIR INFITRATION WATER LEAKAGE
PANEL WIDTH PANEL GAUGEPURLIN
SPACING SEAM UL FM 4471ASTM E-1592
Allowable Uplift ASTM E 1680 ASTM E 1646
24 GA. ROLL-LOCK UL-90 Jan-60 24.1 .0005 CFM/sq.ft. NONE @ 12PSF.
22 GA. ROLL-LOCK 1-90 33.8 .0005 CFM/sq.ft. NONE @ 12PSF.
24 GA. TRIPLE-LOCK UL-90 1-90 42.1 .0005 CFM/sq.ft. NONE @ 12PSF.
22 GA. TRIPLE-LOCK 1-165 24.1 .0005 CFM/sq.ft. NONE @ 12PSF.
24GA. QUAD LOCK 1-165 48.3 .0005 CFM/sq.ft. NONE @ 12PSF.
22 GA. QUAD LOCK NA NO TEST NA NA
24 GA. ROLL-LOCK 1-90 42.2 .0005 CFM/sq.ft. NONE @ 12PSF.
22 GA. ROLL-LOCK 1-90 57.2 .0005 CFM/sq.ft. NONE @ 12PSF.
24 GA. TRIPLE-LOCK 62.4 .0005 CFM/sq.ft. NONE @ 12PSF.
22 GA. TRIPLE-LOCK 1-165 59.8 .0005 CFM/sq.ft. NONE @ 12PSF.
24 GA. QUAD LOCK 1-165 90.5 .0005 CFM/sq.ft. NONE @ 12PSF.
22 GA. QUAD LOCK NA NO TEST NA NA
** Additional design criteria and performance testing available on request.
PANEL DESCRIPTION: 3" Trapizoidal Mechanical Seam Panel, 24 gauge standard (0.023" min.), (ASTM 792, Grade 50), AZ50 aluminum/zinc coated steel, 24" max. width, 3" tall rib, painted or unpainted. Bare galvanized limited warranty - 20 years for integrity and corrosion perforation, "Galvalume" limited warranty - 25 years.
PANEL CLIP & FASTENER: Clips -One piece 22 GA,G90 Galvanized, 3.75" long @ each purlin spacing. Fastener (2) #14 X 1-1/4", #2 Phillips Drive, Low profile head screw per clip. Alternate -Two piece floating, 22GA(upper) 16GA(lower), G90 galvanized, 4.9" long @ each purlin spacing, Fastener (2) #10-12 X 1", #2 Phillips Drive, Low profile head screw per clip. (Corrosion resistant per FBC 2007 Section 1507.4.4)
MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: Per testing listed below based on UL 580/UL 1897 testing, ASTM E-1592 testing, FM 4471 testing.
MINIMUM ROOF SLOPE: 1/4:12 Minimum slope, 6:12 Maximum recommended.
24 GA. TS 324 MECHANICAL SEAM, 3" HIGH / 24" WIDEUPLOAD TEST RESULTS
24" 5'-0"
24" 2'-6"
Tested: 24 gauge 24" wide trapizoidal panel with 3" rib installed over steel purlin @ 5', and 2.5' spacing, with MPS 602 or MPS 603 Clip.TEST BASIS:
Triad Corrugated Metal - Panel Description & Summary Test Data
TESTING ( Dated July, 2008) **
PANEL: TCM 324 (24G / 22 GA 3" x 24")
PAINT SYSTEMS: Silicone polyester (Limited warranty 40 year for integrity and adhesion, 30 year for chalking, 30 year for fade resistance.) Kynar Fluoropon (Limited warranty 35 years for integrity and adhesion, 30 years for chalking, 30 years for fade
ROOF PANEL FIRE RATING: Panel has a Class A fire exposure rating in accordance with FBC Section 1505.3 without an additional fire barrier.
SUBSTRATE: Steel purlins spaced 5'-0" O.C. Purlins support capacity is not addressed in this testing.
VAPOR BARRIER: N/A
Triad Corrugated Metal, Inc. 12/23/09
For additional information call Triad Corrugated Metal. (336) 625-9727 | www.triadmetalroof.com3 REV01.10
TS-324 Eave Section - Eave Gutter
2"panel seam)
GutterEave Trim
Eave Structural
Wall Closure
Wall Fastener
Panel Clip Fastener
Roof Panel
Fastener
Roof Fastener
And ClosureEave Plate
(at every otherGutter Support
Fastener
1"1" or 12 2
Eave
Wall Panel
Endlap Sealant
Roof Insulation Is Not ShownNote: For Clarity Of Detail,
*
* See TCM standard gutter design.
*
For additional information call Triad Corrugated Metal. (336) 625-9727 | www.triadmetalroof.com 4REV01.10
RakeTrim
inside Rake TrimSlide Corner Box
Rivets (typ.)1/8" dia.Gutter
Box over GutterPosition Corner
PanelRoof
(2) 3/16" dia. beadTube Sealant
1/2"
TrimRake
(2) 3/16" dia. beadTube Sealant
RoofPanel
Gutter
CornerBox
1/2"
Closure / Bird Stop
Blind Rivet1/8" dia.
EAVE GUTTERDETAIL
Eave Gutter ISO View
For additional information call Triad Corrugated Metal. (336) 625-9727 | www.triadmetalroof.com5 REV01.10
TS-324 Eave Section -High Eave Trim
Wall Fastener
Wall Panel
High EaveStructural
Wall Closure
Roof Panel ClipPanel Clip Fastener
"or 112
Roof Panel
"21
High Eave Trim
Back-up
Wall Fastener
Plate
End Sealant
End Fastener
Fastener
Flashing Sealant End Dam
*
* See TCM trim design
*
2"1 1/2"
2 1/2"
For additional information call Triad Corrugated Metal. (336) 625-9727 | www.triadmetalroof.com 6REV01.10
High Endwall Section -
Transition FlashingTS-324
or 121" "1
2
"21
* Varies With Roof Pitch*
Back-up Plate
FlashingTransition
Endlap SealantEndlap Fastener
Or Counter FlashWall Panel, Reglet
End DamRoof Panel
Lap FastenerFlashing Sealant
StructuralRoof
~
~
Wall Fastener
ClipRoof Panel
FastenerPanel Clip
2"
4"(min.) 1'-6"(max.)
3"
2 1/2"
5 * *
* *
* * Varies With Roof Run Length
High Eave Section Transition Flashing
For additional information call Triad Corrugated Metal. (336) 625-9727 | www.triadmetalroof.com7 REV01.10
TS-324 Ridge Section
RIDGE SECTION
Varies With Roof Pitch*
PlateBack-up
Panel ClipFastener
Roof Panel StructuralRoof
Clip
End Dam
Flashing SealantLap Fastener
Endlap Sealant
Ridge Flashing
~
"21 or 1 "
21
12"
Roof Panel
* FastenerEndlap2"
3"
2 1/2"
4"(min.) 1'-6"(max.) ~
EndlapFastener
5 Varies With Roof Run Length* * * *
* *
For additional information call Triad Corrugated Metal. (336) 625-9727 | www.triadmetalroof.com 8REV01.10
Ridge ISO View
Roof Panel
Lap Fasteners(typ.)
End Plate
Ridge Cover
Lap Fastener@ 12" o.c.
ProtectivePaper
End Dam ( ZEE )
RakeAngle
1/4" dia. BeadTube Sealant
Side Wall
Butt end of Ridge cover flush against End Plate
Flashing Sealant
Ridge Cover
TS-324
For additional information call Triad Corrugated Metal. (336) 625-9727 | www.triadmetalroof.com9 REV01.10
Starting Rake Section -
Rake Trim
Starting Rake Section
Rake Angle
Wall Fastener
Panel Clip Fastener
Wall Panel
Wall ClosureFastener
Rake Trim
Wall
ClosureWall
Wall PanelFastener
TrimWall
Rake
Slide
Trim
24" O.C.
StructuralRoof
Panel Clip
Panel Clip Fastener
SealantFlashing
Panel Clip
Roof Insulation Is Not ShownNote: For Clarity Of Detail,
**Determined By Manufacturer.
24"
Starting Roof Panel
Lap Fastener2 1/2"
*
Alternate Sliding Rake
Trim (Allows Expansion Movement Of Rake Trim, Required When Roof Run Exceeds 50')
Rake Trim
TS-324
For additional information call Triad Corrugated Metal. (336) 625-9727 | www.triadmetalroof.com 10REV01.10
Valley Section
Valley Section
With Low Panel ClipsValley For Roof Systems
6" (min.)
2"
Valley For Roof SystemsWith High Panel Clips
Varies With Roof Pitch* * Valley Plate
12
"
DiverterWater
1 2"
ClosureCorrugation
Roof Panel
FlashingValley
Roof FastenerEndlap Sealant 12 "
(min
.)
Valley Plate
Roof Panel
FlashingValley
Roof Insulation Is Not ShownNote: For Clarity Of Detail,
Roof Fastener(locate to clearroof structurals)
1
"2 11
TS-324