7/30/2019 Trunking Busbar E-Line_KB
1/33
Busbar Systems
800 A.....6300 A
www.eae.com.tr
Cakmakli Mahallesi, 2. Cadde,
119. Sokak, No:12 34522
Kirac-Hadimkoy-Istanbul-TURKEY
Tel: +90 (212) 886 23 90
Fax: +90 (212) 886 24 20
T E
ME 04
IEC 60439-2 sISO900114001
N LTA ME AM NN AOGRI EV MN
E EN
DT
N SA YY STI TL EA MSUQ
Katalog03/Rev02
2.0
00Ad.
06/01/2009
ATAMATBAACILIK
6124066
/A.C.E./
EAEhasfullrighttomakeanyrevisionsorchancesonthiscataloguewithoutanypriornotice.
-
7/30/2019 Trunking Busbar E-Line_KB
2/33
w w w . e a e . c o m . t r
-
7/30/2019 Trunking Busbar E-Line_KB
3/33
CONTENTS
2-3
4
5
6-9
10
11
12-15
16
17
18-20
21-22
23
23
24-25
26
27
28-29
30
31
32
Introduction
Design & Horizontal Distribution
Design & Vertical Distribution
Technical Characteristics
Order Code System
Standard Components
Elbows
Standard Components
Flexibles / Expansions
Panel Connections
Transformer Connections
Proposed Connection Details to EAE Transformer & Panelboard Modules
Determination of Special Length
Tap-off Boxes
Feeder Boxes
Selection Feeder Boxes
Fixing Elements
EC Conformity Certificate
Certificates
Product Overview
-
7/30/2019 Trunking Busbar E-Line_KB
4/33
2
E KBLINE
EAE Electric manufactures, designs and provides
a wide range of busbar systems from 25 A to 6000 A
busbar systems have many advantages over wire
and conduit.
Lower total installed costBusbar material costs are often equal or less than
wire and conduit.
Lower life cycle cost
Busbar components can be added, deleted or relocated
after the initial installation, saving time and money.
Predictable characteristics
Busbar systems conform to common standards.
Readily published characteristics on busbar
short-circuit ratings, voltage drops, weights and
dimensions can be used.
Fast, flexible engineering
The large number of tap-off points makes it possible
to engineer the power supply systems at an early stage,
even before the final disposition of loads is known.
Flexible power supplyTap-off points at short intervals make electrical power
available in all locations; the power supply can be
adapted to different production processes simply by
relocating the tap-off unit.
E-Line Busbar Systems; conform to EN standards
and are tested according to EN 60439-2 (200).
E-Line Busbar System
Wire Systems
Introduction
-
7/30/2019 Trunking Busbar E-Line_KB
5/33
3
E KBLINETechnical Features
GeneralThe perfect design for high current busbar systems
is the "compact structure" where tin plated and insulated with B
class polyester film and extruded polypropylene sleeve polyester
film on conductors are tightly placed into the sheet metal
housing (Figure 1).
One bolt joint ensures safety andeasy installationE-Line KB busbars are installed by tightening the
"one bolt joint". Belleville spring washers on both endsof the bolt retains the original contact pressure, ensuringa more secure, reliable and maintenance - free joint.E-Line busbar systems are easily installed (Figures 2-3).
* The bolt is tightened to 83 Nm (60 lbft) using the torque spanner.
Heat Transfer"In compact structure" there is no empty space filled with
air and heat is easily transferred to the environment by thehousing that works like a heat-shink (Figure 4).
High Short-Circuit EnduranceAs there are no support points in "compact structure"
momentum levers are not formed.This feature ensures high short-circuit endurance.
Minimum Voltage DropIn E-Line KB, inductive reactance is very low due toclosely placed conductors (Figures 1-4).
The voltage drop comparison of compact and ventilatedbusbar that have same cross sectional area provethe importance of the compact structure (Figure 5).
Standard Prefabricated Structure
E-Line KB busbar system can be adapted toany kind of building structure using.Space-saving prefabricated components.
All necessary components and fitting elements
are manufactured items.
* Special components can be manufactured in one week on request.
No Need For Fire Barrier
There is no risk of chimney effect in E-Line KB'scompact structure. Internal fire barriers are not needed.
Figure 3
Figure 4
Figure 2
Insulators
L12
3
LLN
PE
Voltage Drop
Line length (m)100 m50 m
0
3
6
9
13,3
Figure 5
KBA1000 Busbar
Section: 700 mm
Ventilated Busbar
Section: 700 mmI: 1000A
cos :0,8
Figure 1
Conductors (Al, Cu)Tin plated
50
60
83Nm(60lbft)Torqu Spanner
pregalvanized sheet metal orepoxy polyester paintedpregalvanized sheet metal RAL 7038
B classpolyester film
extruded
polypropylenesleeve
-
7/30/2019 Trunking Busbar E-Line_KB
6/33
4
E KBLINEDesign & Horizontal Distribution
While designing an electrical distributionsystem with E-Line KB a few approximatedetails will be necessary.
Location, number, type and approximate ratingsof loads,Transformer rates and short-circuit capacities,
Utilization factor=,System coordination with other distribution system
(heat, water, etc ),Determining the route of E-Line KB on layout,If necessary, coordination of E-Line KB Busbar withE-Line KO runs,
Deciding on suitable hanger types.
Utilization Factor ()Utilization factor () depends on the type and
number of loads.It is usually around 0.7 or lower. The utilization factorof a line that supplies electricity to motors and lightingsystems is usually lower than 0.6.
It is as low as 0.30 in weld shops of car factories,
can be 1 in lines where only one big load is supplied.
Voltage DropFor practical voltage drop calculation, necessary
values, formula and easy calculation methods aregiven on the technical characteristics table on pages 6-9.
Rated CurrentThe current is calculated using the following equation:
Short-CircuitTested short-circuit capacities are given on technicalcharacteristics table on pages 6-9.
Busbar Installation PlanOur distributor's project & design departmentswill help you for preparing the installation plans on
request.
Busbar current rating is chosen as equal to or higher
then the calculated IB current.
After the voltage drop calculation if the chosen
current rate is not convenient, a higher rating is
chosen.
B
P.
3.U.cos I =
BI
P
U
= Operation current (A)
= Installed load (W)
= Utilization factor
= Supply voltage (V)
QuantityComponents
Components List
Item
Name : Ercan Yldz
Date : 18 / 10 / 1994
Signature:
Project Sample
Preparedb
y
KBA 2050 - STD Busbar (20 x 3m.) 60 m.
2 pc.
1 .pc
1 .pc
1 .pc
1 .pc
1 .pc
1 .pc
1 .pc
1 .pc
1 .pc
1 .pc
8 .pc
6 .pc
1
2
3
4
4
4
5
6
7
8
9
10
11
12
KBA 2050 - D Downwards Elbow
KBA 2050 - R Right Elbow
KBA 2050 - U Upwards Elbow
KBA 2050 - L Left Elbow
KBA 2050 - P11 Panel Connection
KBA 2050 - S10 End Closer
KBA 2050 - X85 Special Straight Length
KBA 2050 - X105 Special Straight Length
KBA 2050 - X107 Special Straight Length
KBA 2050 - X176 Special Straight Length
KBA 2050 - X142 Special Straight Length
KBB 1650 Tap-off Box
KBB 2550 Tap-off Box
Company : Yener Tekstil
Project : orlu Tesisleri
Project No : 0120
54 m. (18 pc. x 3 m.)KBA 2050
8 pc. KBB 16506 pc. KBB 2550
-
7/30/2019 Trunking Busbar E-Line_KB
7/33
-
7/30/2019 Trunking Busbar E-Line_KB
8/33
-
7/30/2019 Trunking Busbar E-Line_KB
9/33
Copper Conductor (Cu)
* New product group
Technical Characteristics
Measurements and calculations of fault-loop circuit is done according to EN 60439-2 appendix N2b.(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
Busbar Code
Rated Current
Fault LoopResistance (R PH-N)0
Fault LoopResistance (R PH-N)0
4 conductors
4 conductors
4 conductors
4,5 conductors
4,5 conductors
4,5 conductors
Fault LoopResistance (R PH-PE)0
Fault LoopReaktance (X PH-N)
Fault LoopReaktance (X PH-N)
Fault LoopReactance (X PH-PE)
Fault LoopImpedance (Z PH-N)0
Fault LoopImpedance (Z PH-N)0
Fault LoopImpedance (Z PH-PE)0
Standards
Rated Operational Voltage
Rated Insulation Voltage
Rated Frequency
Protection Degree
Housing Material
9
In A 1000 1250 1600 2000 *2250 2500 3000 3600 *4250 4400 5300 *6300
Short-circuit(peak)
Short-circuit Valueof Neutral Conductor(1 sec)
Short-circuit Valueof Protective Circuit(1 sec)
Short-circuit Valueof Neutral Conductor(peak)
Short-circuit Valueof Protective Circuit(peak)
Short-circuit(1 sec)
R 20 C(Calculation)20
Impedance
Ue
Ui
Icw
Icw
Ip
Ip
Ip
Icw
20
20
R
Z
f
IP
V
V
kA
kA
kA
kA
kA
kArms
m/m
m/m
Hz
IEC 60439-2: 2005-10
10 12 16 20 23 25 30 36 42 44 53 63
50
105
30
63
30
63
0,0350
0,0510
50
105
30
63
30
63
0,0260
0,0390
50
105
30
63
30
63
0,0200
0,0300
50
105
30
63
30
63
0,0160
0,0250
100
220
60
132
60
132
0,0170
0,0260
100
220
60
132
60
132
0,0130
0,0190
100
220
60
132
60
132
0,0100
0,0160
100
220
60
132
60
132
0,0080
0,0120
120
264
72
158
72
158
0,0090
0,0130
120
264
72
158
72
158
0,0070
0,0100
120
264
72
158
72
158
0,0050
0,0090
1000
1000
50/60
55
50
105
30
63
30
63
0,0400
0,0580
L1, L2, L3, N
PE(for 5 conductors)
Weight - 4 Conductors
Weight - 5 Conductors
Housing Cross Section(Sheet Metal)
PE(for 4 conductors)
Conductor Size
Resistance(at Rated Current,at Steady State Op. Temp.)Reactance(at Rated Current)
Impedance(at Rated Current)
Losses at Rated Current 13I R
1R
1X
1Z
0R
0
0
R
R
X
X
X
0Z
0
0
Z
Z
mm
mm
kg/m
kg/m
mm
mmxmm
mm
m/m
m/m
m/m
W/m
m/m
m/m
m/m
m/m
m/m
m/m
m/m
m/m
m/m
229,69
0,0490
0,0380
0,0620
525
525
262,5
918
7x75
28
33
0,0940
0,0990
0,1380
0,3050
0,1450
0,2470
0,1360
0,3940
0,2000
276,48
0,0360
0,0290
0,0460
700
700
350
968
7x100
36
42
0,0690
0,0790
0,1070
0,2600
0,1090
0,1530
0,1110
0,3040
0,1560
336,00
0,0280
0,0230
0,0360
910
910
455
1028
7x130
44
52
0,0540
0,0600
0,0830
0,2380
0,0870
0,1120
0,0870
0,2690
0,1240
349,31
0,0230
0,0190
0,0290
1120
1120
560
1088
7x160
52
60
0,0440
0,0580
0,0740
0,2110
0,0690
0,0810
0,0790
0,2330
0,1050
468,75
0,0250
0,0190
0,0310
1050
1050
525
1836
2x(7x75)
54
64
0,0480
0,0510
0,0710
0,1920
0,0680
0,1050
0,0710
0,2200
0,0990
513,00
0,0190
0,0140
0,0240
1400
1400
700
1936
2x(7x100)
70
82
0,0350
0,0410
0,0550
0,1840
0,0540
0,1440
0,0570
0,2380
0,0790
466,56
0,0120
0,0120
0,0170
1820
1820
910
2056
2x(7x130)
86
102
0,0260
0,0330
0,0430
0,1240
0,0400
0,1310
0,0460
0,1800
0,0620
541,88
0,0100
0,0090
0,0140
2240
2240
1120
2176
2x(7x160)
102
118
0,0250
0,0270
0,0370
0,1230
0,0390
0,1140
0,0360
0,1700
0,0530
638,88
0,0110
0,0100
0,0150
2100
2100
1050
2904
3x(7x100)
104
122
0,0240
0,0290
0,0380
0,1110
0,0360
0,1050
0,0420
0,1540
0,0560
589,89
0,0070
0,0080
0,0110
2730
2730
1365
3084
3x(7x130)
128
152
0,0180
0,0230
0,0300
0,0890
0,0290
0,1090
0,0330
0,1410
0,0440
714,42
0,0060
0,0070
0,0090
3360
3360
1680
3264
3x(7x160)
152
187
0,0130
0,0220
0,0250
0,0720
0,0200
0,0890
0,0310
0,1150
0,0380
174,00
0,0580
0,0410
0,0710
450
450
225
918
6x75
26
31
0,1120
0,0900
0,1470
0,3110
0,1540
0,2550
0,1290
0,4030
0,2020
E KBC-LINE
Voltage Drop Calculation
Voltage drop of a busbar system can becalculatedwith the following formula taking
into account the"" load distributionconstant.
V=3.L.I.(R .Cos+X .Sin) 101 1-3
= Voltage Drop (V)
= Load Distribution Constant
= Line Length (m)
= Line Current (A)
= Resistance (m/m)
= Inductive Reactance (m/m)
= Load Factor
V
L
I
R1X1
Cos
V
Load Distribution Factor
L
L1
L1
L1
L1
L2
L2
L2
L3
L3
L3
L2
L4
L4
L4
F
F
F
F
FF
L
F= Supply
L= Load
F= Supply
L1,L2,L3,L4
Load
F= Supply
L1,L2,L3,L4
Load
F= Supply
L1,L2,L3,L4
Load
F= Supply
L1,L2
Load
1.00
0.50
0.125
0.25
0.25
1,50 mm epoxy polyester painted pregalvanized sheet metal RAL 7038pregalvanized sheet metal or
-
7/30/2019 Trunking Busbar E-Line_KB
10/33
KB A 16 5 0 T R 4 1
0
Feeder
Plug-in
Bolt-on
IP 55 5
Bolt-onPlug-inFedeer
012
4 il. 5 il. 4+
345
678
KBA
AluminiumCopper
(Al) A(Cu)
Order Code System
E KBLINE
*TYPE Utilization Type
Energy is suplied
from the joints.
Energy is supplied either
from the joints or theplug-in points.
Used where there is no need
to use tap-off boxes.
COMPONENTS
TYPE*
PROTECTION DEGREE
BUSBAR
CODE
CONDUCTOR TYPE
Unpainted -
Painted B
Conductors
Busbar Type
* New product group
Al
Conductor
Cu
Conductor
Conductor
Size
Rated
Current
Rated
Current
Busbar
Code
Busbar
Code
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
UTILIZATION TYPE
COMPONENT
UNPAINTED / PAINTED
Standard LengthSpecial LengthUpwards ElbowDownwards ElbowRight ElbowLeft Elbow
Upwards Vertical OffsetDownwards Vertical OffsetRight Horizontal OffsetLeft Horizontal Offset
Right Upwards Combined OffsetLeft Upwards Combined OffsetRight Downwards Combined OffsetLeft Downwards Combined OffsetUpwards Right Combined OffsetUpwards Left Combined OffsetDownwards Right Combined OffsetDownwards Left Combined Offset
Left Side Feeder "T"Right Side Feeder "T"Central Feeder "T"
Horizontal Expansion
Vertical Expansion
ReductionEnd CloserEnd Closer
Panel ConnectionPanel ConnectionUpwards Panel ConnectionUpwards Panel ConnectionDownwards Panel ConnectionDownwards Panel ConnectionRight Panel ConnectionRight Panel Connection
Left Panel ConnectionLeft Panel ConnectionPanel ConnectionPanel Connection
Transformer ConnectionUpwards Transformer ConnectionDownwards Transformer ConnectionTransformer ConnectionTransformer ConnectionRight Transformer ConnectionLeft Transformer ConnectionTransformer Connection
Flexible
Feeder BoxFeeder BoxCentral Feeder Box
STDX
UDRL
UVDVRHLH
KRUKLUKRDKLDKURKULKDRKDL
TYLTYRTO
YDT
DDT
RDS10S11
P10P11PU20PU21PD20PD21PR30PR31
PL30PL31P40P41
TR11TU21TD21TR31TR41TR51TL51TR61
F
B10B11BO
800
1000
1250
1600
1600
2000
2500
3050
3100
4000
4250
5000
*
*
*
*
6x75
7x75
7x100
7x130
7x160
2x(7x 75)
2x(7x100)
2x(7x130)
2x(7x160)
3x(7x100)
3x(7x130)
3x(7x160)
4x(7x130)
08
10
12
13
16
20
25
27
30
40
41
50
1000
1250
1600
2000
2250
2500
3000
3600
4250
4400
5300
6300
-------
10
12
16
20
23
25
30
36
42
44
53
63
---
*
*
*
-
7/30/2019 Trunking Busbar E-Line_KB
11/33
0
1
2
3050
- STD
- STD
KBA 2552
- STD
Bolt-on
Plug-in
Feeder
3000
X
L1L2L3N
L1L2L3N
L1L2L3N
L1L2L3N
2551
2552 -147
11
KB
E KBLINE
Electrical energy up to 800 A can be
supplied from the joints of bolt-on type
by bolt-on tap-off boxes.
As feeder or sub-feeder line,
Where a load has to be supplied
from the busbar.
Electrical energy up to 800 A can be
supplied from the joints and up to 400 A
can be supplied from the plus.
In application of bolt-on
As vertical feeder line high rise buildings
For frequent energy supply
For applications where there is no need
to use tap-off boxes.
Transformer - panel connections
Main panel - sub-panel connections
Generator, composition supplies
Sample Order:2500 A, Copper, Plug-in,IP 55, 4 Conductors
Sample Order:2500 A, Aluminium,Feeder, IP 55, 4 Conductors
Sample Order:2500 A, Copper, Feeder, IP 55,4 Conductors, 147 cm
Sample Order:3000 A, Copper, Bolt-on,IP 55, 4 Conductors
Minimum Length = 35 cm
XSpecial Straight
Length in (cm)
Bolt-on
Plug-in
Feeder
Special Straight Length
Busbar cross-section dimesions
* New product group
Standard Straight Length
3000
3000
L1L2L3N
L1L2L3N
L1L2L3N
NL3L2L1
950
Bolt-on
Bolt-on
Bolt-on
Bolt-on
Plug-in Plug-in
1100
3000
950
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
COMPONENT
UNPAINTED / PAINTED
095
1100
3000
509
800
1000
1250
1600
1600
2000
25003050
3100
4000
4250
5000
*
*
*
*
130
130
155
185
215
250
300
360420
445
535
625
710
08
10
12
13
16
20
2527
30
40
41
50
KBA
1000
1250
1600
2000
2250
2500
3000
36004250
4400
5300
6300
------
10
12
16
20
23
25
30
3642
44
53
63
---
A
(mm)
*
*
*
Al
Conductor
Cu
Conductor
Rated
Current
Rated
Current
Busbar
Code
Busbar
Code
-
7/30/2019 Trunking Busbar E-Line_KB
12/33
- U
325
400
325
400
L1L2L3N
3050 - D
- D 325
400
325 4
00L1
L2L3N
- L
B A
B A
L1L2L3N
KBA 2050 - R
- R
BA
B
A
L1L2L3
N
3050 - U
2550 - L
2
KB
E KBLINEElbows
Please call us for non-standard components.
Sample Order:
3000 A, Copper, Bolt-on,
IP 55, 4 Conductors
Upwards Elbow
Sample Order:3000 A, Copper, Bolt-on,
IP 55, 4 Conductors
Downwards Elbow
Sample Order:2500 A, Copper, Bolt-on,
IP 55, 4 Conductors
Left Elbow
Sample Order:
2000 A, Aluminium, Bolt-on,IP 55, 4 Conductors
Right Elbow
* New product group
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
COMPONENT
UNPAINTED / PAINTED
The dimensions given above are minumum values.
800
1000
1250
1600
1600
2000
2500
3050
3100
4000
4250
5000
*
*
*
*
420
420
445
475
505
540
590
650
710
735
825
915
1000
355
355
367
383
398
415
440
470
500
512
558
603
645
08
10
12
13
16
20
25
27
30
40
41
50
KBA
1000
1250
1600
2000
2250
2500
3000
3600
4250
4400
5300
6300
------
10
12
16
20
23
25
30
36
42
44
53
63
---
A B
(mm) (mm)
*
*
*
Al
Conductor
Cu
Conductor
Rated
Current
Rated
Current
Busbar
Code
Busbar
Code
-
7/30/2019 Trunking Busbar E-Line_KB
13/33
KBA 2050-UV45
- LH
- RH
- UV
- DV
x
x
Y
Y
(cm)
(cm)
(cm)
(cm)
B
B
B
B
A
A
X
X
A
A
Y
23 5
40023 5
400
Y 23 5
04 0
23 5
400
L1L2L3N
L1L2L3N
L1
L2L3N
L1L2
L3N
3050 - RH60
3050 - DV45
13
KB
E KBLINEElbows
X=min:20 cm,max: *Please see table
Sample Order:X=60 cm, 3000 A, Copper
Bolton, IP 55, 4 Conductors
X=min:20 cm,
max: *Please see table
Sample Order:
X=60 cm, 3000 A, CopperBolton, IP 55, 4 Conductors
Y=min:15 cm / max:64 cm
Sample Order:
Y=45 cm, 2000 A, AluminiumBolt-on, IP 55, 4 Conductors
Y=min:15cm / max:64 cmSample Order:
Y=45 cm, 3000 A, Copper
Bolt-on, IP 55, 4 Conductors
Left Horizontal Offset
Right Horizontal Offset
Upwards Vertical Offset
DownwardsVertical Offset
* New product group
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
COMPONENTS
UNPAINTED / PAINTED
The dimensions given above are minumum values.
3050 - LH60
800
1000
1250
1600
1600
2000
2500
3050
3100
4000
4250
5000
420
420
445
475
505
540
590
650
710
735
825
915
1000
355
355
367
383
398
415
440
470
500
512
558
603
645
70
70
73
76
78
82
87
93
99
102
111
120
128
08
10
12
13
16
20
25
27
30
40
41
50
KBA
1000
1250
1600
2000
2250
2500
3000
3600
4250
4400
5300
6300
------
10
12
16
20
23
25
30
36
42
44
53
63
---
A B X
(mm) (mm) (cm)
*
*
*
*
*
*
*
Al
Conductor
Cu
Conductor
Rated
Current
Rated
Current
Busbar
Code
Busbar
Code
-
7/30/2019 Trunking Busbar E-Line_KB
14/33
KBA 3050-KDR
KBA 3050-KUR
- K D L
- K U L
KUL
KDL
KUR
KDR
- K D R
- K U R
532
040
B
300
A
253
004
B
300
A
532
040
B
300
A
325
400
B
300
A
L1L2L3N
L1L2L3N
L1L2L3N
L1L2L3N
3050 - KUL
3050 - KDL
4
KB
E KBLINEElbows
Please call us for non-standard components.
Sample Order:
3000 A, CopperBolt-on, IP 55, 4 Conductors
Sample Order:3000 A, Aluminium
Bolt-on, IP 55, 4 Conductors
Sample Order:
3000 A, Copper
Bolt-on, IP 55, 4 Conductors
Sample Order:
3000 A, AluminiumBolt-on, IP 55, 4 Conductors
Upwards RightCombined Offset
Downwards RightCombined Offset
Upwards LeftCombined Offset
Downwards LeftCombined Offset
* New product group
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
COMPONENT
UNPAINTED / PAINTED
The dimensions given above are minumum values.
800
1000
1250
1600
1600
2000
2500
3050
31004000
4250
5000
*
*
*
*
420
420
445
475
505
540
590
650
710
735825
915
1000
355
355
367
383
398
415
440
470
500
512558
603
645
08
10
12
13
16
20
25
27
3040
41
50
KBA
1000
1250
1600
2000
2250
2500
3000
3600
4250
44005300
6300
------
10
12
16
20
23
25
30
36
42
4453
63
---
A B
(mm) (mm)
*
*
*
Al
Conductor
Cu
Conductor
Rated
Current
Rated
Current
Busbar
Code
Busbar
Code
-
7/30/2019 Trunking Busbar E-Line_KB
15/33
KBA 3050-KLD
KBA 3050-KLU
- K L D
- K L U
KLU
KLD
KRU
KRD
- K R D
- K R U
23
5
400
B300
A
32
5 400
B
300
A
325
00
4
B
300
A
32
5 00
4
B
30
0
A
L1L2L3N
L1L2L3N
L1
L2L3N
L1L2L3N
3050 - KRU
3050 - KRD
15
KB
E KBLINEElbows
Please call us for non-standard components.
Sample Order:
3000 A, AluminiumBolt-on, IP 55, 4 Conductors
Sample Order:
3000 A, AluminiumBolt-on, IP 55, 4 Conductors
Sample Order:3000 A, Copper
Bolt-on, IP 55, 4 Conductors
Sample Order:3000 A, Copper
Bolt-on, IP 55, 4 Conductors
Right UpwardsCombined Offset
Right DownwardsCombined Offset
Left UpwardsCombined Offset
Left DownwardsCombined Offset
* New product group
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
COMPONENT
UNPAINTED / PAINTED
The dimensions given above are minumum values.
800
1000
1250
1600
1600
2000
2500
3050
31004000
4250
5000
*
*
*
*
420
420
445
475
505
540
590
650
710
735825
915
1000
355
355
367
383
398
415
440
470
500
512558
603
645
08
10
12
13
16
20
25
27
3040
41
50
KBA
1000
1250
1600
2000
2250
2500
3000
3600
4250
44005300
6300
------
10
12
16
20
23
25
30
36
42
4453
63
---
A B
(mm) (mm)
*
*
*
Al
Conductor
Cu
Conductor
Rated
Current
Rated
Current
Busbar
Code
Busbar
Code
-
7/30/2019 Trunking Busbar E-Line_KB
16/33
KBA 2050-RD16
KBA 2550-TYL
- T Y L
- T Y R
- T O
- RD
- S 1 0
- S 1 1
600
1000
665
335
B
A
C
B
A
C
B
A
C
600
L1L2L3N
L1L2L3N
L1L2L3N
L1L2L3N
L1L2L3N
L1L2L3N
2550 - S11
2550 - TYR
3050 - TO
6
KB
E KBLINE
Sample Order:
2500 A, Copper, Bolt-on,IP 55, 4 Conductors
Sample Order:
2500 A, Copper, Bolt-on,IP 55, 4 Conductors
Reduction
End Closer
Is used to close the end of busbar run.
Is used to change the busbar cross section.
Sample Order:
2000A / 1600A, Aluminium,Bolt-on, IP 55, 4 Conductors
Sample Order:2500 A, Aluminium, Bolt-on,
IP 55, 4 Conductors
Sample Order:
2500 A, Copper, Bolt-on,
IP 55, 4 Conductors
Sample Order:
3000 A, Copper, Bolton,
IP 55, 4 Conductors
End Closer
End Closer
Reduction
Left Side Feeder "T"
Right Side Feeder "T"
Central Feeder "T"
800 A - 081000 A - 10
1250 A - 121600 A - 13
1600 A - 16
2000 A - 202500 A - 25
3050 A - 273100 A - 30
4000 A - 404250 A - 41
5000 A - 50
Standard Components
Please call us for non-standard components.
* New product group
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
COMPONENT
UNPAINTED / PAINTED
The dimensions given above are minumum values.
2550 - S10
800
1000
1250
1600
1600
2000
2500
3050
3100
4000
4250
5000
*
*
*
*
420
420
445
475
505
540
590
650
710
735
825
915
1000
355
355
367
383
398
415
440
470
500
512
558
603
645
710
710
735
765
795
830
880
940
1000
1025
1115
1205
1290
08
10
12
13
16
20
25
27
30
40
41
50
KBA
1000
1250
1600
2000
2250
2500
3000
3600
4250
4400
5300
6300
------
10
12
16
20
23
25
30
36
42
44
53
63
---
A B C
(mm) (mm) (mm)
*
*
*
Al
Conductor
Cu
Conductor
Rated
Current
Rated
Current
Busbar
Code
Busbar
Code
-
7/30/2019 Trunking Busbar E-Line_KB
17/33
B=.....mm
X=.....mmY=.....mmZ=.....mm=.....mm
L(cm)
KBA 2550-YDT
KBA 0800-F40
- Y D T
- D D T
- F
*
Y
L
B
Z
X
700
1500
L1L2L3N
L1L2L3N
4250 - DDT
17
KB
E KBLINE
Sample Order:2500 A, Aluminium, Bolt-on, 4 Conductors
Sample Order:4250 A, Copper, Bolt-on, 4 Conductors
Sample Order:800 A, Aluminium
This side is punched accordingto the needs of the custommer.
Used at every 40 m in horizontallong lines and for crossing buildingexpansions.
For vertical application in many storeybuilding.
Transformer - busbar,
Panel - busbar connections.
One vertical expansion unit is advisedto be used at every floor betweenfixed support points.
Horizontal Expansion
Vertical Expansion
Flexibles
Horizontal Expansion
Vertical Expansion
Flexible are used for
Flexibles & Expansions
Please call us for non-standard components.
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
COMPONENT
UNPAINTED / PAINTED
Attention!The total length of the module should be adjustedto 1500 mm. after installation.
The dimensions given above are minumum values.
-
7/30/2019 Trunking Busbar E-Line_KB
18/33
2550 - P10
3650 - PU20
4250 - PD20
Sample Order:
2500 A, Copper, Bolt-on,for Panel Feeder
Attention !...
The position of the panel board conductors
and the position of the busbar according
to panel board must be taken into accountbefore installation.
Side is defined as 0
Side is defined as 1
Panel Feeder
Panel Feeder
Panel Feeder
Panel Connection
Upwards Panel Connection
Downwards Panel Connection
Panel Connections
* Please call us for non-standard components..** Panel connection unit connection bars have M12x40 size screws.
1 E-Line KB Busbar
2 Panel ConnectionPlate
3 Opening on thepanel board
Sample Order:
3600 A, Copper, Bolt-on,
for Panel Feeder
- P 1 0
- P U 2 0
- P D 2 0
Sample Order:4250 A, Copper, Bolt-on,
for Panel Feeder
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
The dimensions given above are minumum values.
KB
L1
L1N
N
L3
L2L3L2
N
NL1
L1L2
L3
L2L3
PU20
PD20 NL3
L2L1
325
400
325 4
00
150
L1L 2
L3N
253
040
325 4
00
150
100
100
L1
L1
L2
L2
L3
L3
N
N PE
100
100
100
100 100
8
E KBLINE
50
50
Aluminium (Al) Copper (Cu)
Rated
Current
Rated
Current
800
1000
1250
1600
08
10
12
13
1000
1250
1600
2000
2250
10
12
16
20
23
75
75
100
130
160
40
40
40
40
40
17,5
17,5
30
25
20
225
225
250
280
310
175
175
200
230
260
4
4
4
5
6
6x75
7x75
7x100
7x130
7x160
BusbarCode
BusbarCode
ConductorsA
(mm)
B
(mm)
C
(mm)
D
(mm)
E
(mm) Figure
1
1
2
2
4 5 6
100
100
100
100
100
515
D
D
E
465
150
BC C23
12,5
12,5
14
7
A
2
1
3
100
100
100
100
100
515
D
D
E
465
150
B B BC C23
12,5
12,5
14
7
A
2
1
3
100
100
100
100
100
515
D
D
E
465
150
B BC C23
12,5
12,5
14
7
A
2
1
3
P10L1
N
L 2
L3
L3
L2L1
N
150
250
50
-
7/30/2019 Trunking Busbar E-Line_KB
19/33
* Please call us for non-standard
components.
Attention !...
The position of the panel board conductors
and the position of the busbar according
to panel board must be taken into accountbefore installation.
The dimensions given aboveare minumum values.
P11 L1N
L 2
L3L2
L1
PU21
PD21
150
250
532
040
325 4
00
150
L1L 2
L3N
NL3
L2L1
532
040
325 4
00
150
19
Busbar Connection
E KBLINE
50
50
50
L3N
2
2500
3000
3600
4250
1600
2000
2500
3050
25
30
36
42
16
20
25
30
196
246
306
366
40
40
40
40
17,5
30
25
20
345
395
455
515
295
345
405
465
4
4
5
6
2(7x75)
2(7x100)
2(7x130)
2(7x160)
A(mm)
B(mm)
C(mm)
D(mm)
E(mm)
100 100 100
100
100
100
100 100 100100 100 100
100
100
100
100
100
100
515
515
515
D D D
D D D
E E E
465
465
465
150
50
150
50
150
50
B B B B B BB B B B B BC C CC C C
23
23
23
12,5 12,5 12,5
12,5
12,5
12,5
14 14 14
7 7 7
A A A
2 2
1 1 1
3 3 3
4 5 6
L1
L1N
N
L3
L2L3L2
N
NL1
L1L2
L3
L2L3
2550 - P11
3650 - PU21
4250 - PD21
Sample Order:
2500 A, Copper, Bolt-on,for Busbar Feeder
Busbar Feeder
Busbar Feeder
Busbar Feeder
Busbar Connection
Upwards Panel Connection
Downwards Busbar Connection
Sample Order:
3600 A, Copper, Bolt-on,
for Busbar Feeder
- P 1 1
- P U 2 1
- P D 2 1
Sample Order:4250 A, Copper, Bolt-on,
for Busbar Feeder
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
Aluminium (Al) Copper (Cu)
Rated
Current
Rated
Current
BusbarCode
BusbarCode
Conductors Figure
-
7/30/2019 Trunking Busbar E-Line_KB
20/33
0The dimensions given above are minumum values.
* Please call us for non-standard components.
4 5 6
L1
L1N
N
L3
L2L3L2
N
NL1
L1L2
L3
L2L3
PL31
PR31
NL3
L2L1
PR30
A
B
150
A
B
NL3L2L1
PL30
P40 P41
860
200
L1
L1
L1
L2
L2L2
L3 L3NN
N
516
165
165
165 16
5
110
165
011L1
L2L3 L3
N
086
200
Panel Connection
E KBLINE
50
A
B
150
A
B
50
NL3
L2L1
A
B
150
A
B
NL3L2L1
50
A
B
150
A
B
50
2 2
100 100100 100
100
100
100 100100 100100 100
100
100
100
100
515
515
D D
D D
E E
465
465
150
150
50
50
B B BB B BB B BC CC CC C
23
23
12,5 12,5
12,5
12,5
14 14
7 7
A A
1
3
1
3
100
100
L1
4 Conductors
5 Conductors
L1
L2
L2
L3
L3
N
N PE
100
100
100
100 100
1
1
2
2
2
100100
100
100 100 100
100
100
515
D
D
E
465
150
50
B B B B B B BB BC C C
23
12,5
1
2,5
14
7
A
1
3
A and B dimensions of PL30 and PL31 are same
as left and right elbows, please refer to page 12
for the dimensions.
2550 - PR30
4250 - PL31
3050 - P40
Right Panel Connection
Left Panel Connection
Sample Order:2500 A, Copper, Bolt-on,
for Panel Feeder
Sample Order:4250 A, Copper, Bolt-on,
for Busbar Feeder
Panel FeederBusbar Feeder
Panel Feeder
Busbar Feeder
- P R 3 0- P R 3 1
- P L 3 0
- P L 3 1
- P 4 0- P 4 1
Panel Connection
Sample Order:
3000 A, Copper, Bolt-on,for Busbar Feeder
Panel FeederBusbar Feeder
Attention !...
The position of the panel board conductors
and the position of the busbar according
to panel board must be taken into accountbefore installation.
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
UNPAINTED / PAINTED
COMPONENT
KB
1 E-Line KB Busbar
2 Panel Connection Plate
3 Opening on the panel board
4400
5300
6300
------
3100
4000
4250
5000
44
53
63
---
30
40
41
50
392
482
572
658
40
40
40
40
30
25
20
25
545
635
725
812
495
585
675
762
4
5
6
-
3(7x100)
3(7x130)
3(7x160)
4(7x130)
A
(mm)
B
(mm)
C
(mm)
D
(mm)
E
(mm)
Aluminium (Al) Copper (Cu)
Rated
Current
Rated
Current
BusbarCode
BusbarCode
Conductors Figure
-
7/30/2019 Trunking Busbar E-Line_KB
21/33
KBA 2552-TR11
KBA 2552-TD21
2552 - TU21
2550 - TR31
Please call us for non-standard components.
Sample Order:2500 A, Aluminium, Feeder, 4 Conductors
Sample Order:2500 A, Copper, Feeder, 4 Conductors
Sample Order:2500 A, Aluminium, Feeder, 4 Conductors
Sample Order:2500 A, Copper, Bolt-on, 4 Conductors
For transformer and panel connectionapplications EAE design and planninggroup will prepare your projects uponrequest.
For the design the following informations are
required;
Plan of transformer and panel board room,heights.Transformer dimensions, distance betweenbushings.Panel board dimensions.
TransformerConnection
TransformerConnection
UpwardsTransformer Connection
DownwardsTransformer Connection
Transformer Connections
For connection dimensions please referto tables on pages 18, 19 and 20.
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
COMPONENT
UNPAINTED / PAINTED
- T R 1 1
- T R 3 1
- T U 2 1
- T D 2 1
The dimensions given above are minumum values.
KB
L 1
L 2
L 3
N
TR11
TR31
TU21
TD21
L1
N
L 2
L 3
L 3
L2
N
L1
165
mi 25
5n
860
165
101
165
L1
L1
L2
L2L3 L3
N
N
200
150
250
NL 3
L2L1
325
400
5
32
400
150
L1L 2
L3N
325
040
5
32
400
150
21
E KBLINE
50
50
50
-
7/30/2019 Trunking Busbar E-Line_KB
22/33
Transformer Connections
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
COMPONENT
UNPAINTED / PAINTED
KB
KBA 2552-TL51
2550 - TR41
3650 - TR61
2552 - TR51
Sample Order:2500 A, Copper, Feeder,4 Conductors
Sample Order:2500 A, Aluminium, Feeder,
4 Conductors
Sample Order:2500 A, Copper, Bolt-on,4 Conductors
TransformerConnection
RightTransformer Connection
LeftTransformer Connection
Sample Order:3600 A, Copper, Bolt-on,4 Conductors
TransformerConnection
- T R 6 1
TR61
670
2000
290
670
020
L 1
L 2
L 3
Nmin.
110
mn
11i .
0
TR51
TL51
670
2000
290
670
L 1
L 2
L 3
N
NL3
L2L1
- T R 4 1
- T R 5 1
- T L 5 1
- T R 4 1
nmi
.
110
TR41mn 25
i .0
2
E KBLINE
NL3
L2L1
A
B
150
A
B
50
A
B
150
A
B
50
L 1
L 2
L 3
N
250
150
200
min.100
Please call us for non-standard components.
Please refer to page 12 for the dimensions.
A and B dimensions of TR51 and TL51 are sameas left and right elbows.
For transformer and panel connectionapplications EAE design and planninggroup may prepare your projects uponrequest.
For Project;
Plan of transformer and panel board room,
heights.Transformer dimensions, distance betweenbushings.Panel board dimensions.
The dimensions given above are minumum values.
-
7/30/2019 Trunking Busbar E-Line_KB
23/33
A
23
E KBLINE
Proposed Connection Details to EAE Transformer & Panelboard Modules
Determination of Special Length
After the installation of standard 3m lengths, you will be in need of special lengths which are smaller than 3m. The minimum
length for these special elements can be 35 cm. Please measure the lengths of these modules as shown below.
busbar
"A" length should be indicated in cm. Measure the asistance from one end of the side housing to the other.
A=Length of Special Busbar
-
7/30/2019 Trunking Busbar E-Line_KB
24/33
A
(mm)
B
(mm)
C
(mm)
E KBLINETap-off Boxeswith Fused Switches (SYK)
KB
BUSBAR TYPE
CONDUCTOR
PROTECTION
DEGREE
RATED CURRENT
BOX TYPE
IP-55-5
4 - 05 - 1
160 A-16250 A-25400 A-40630 A-63
Bolt on- BPlug in- P
CABLE GLAND PLATES
Please call us for non-standard tap-off boxes.
Cable Gland Plates
Tap-off boxes are equipped withEAE SYK fused switchesThe tap-off boxes are in red RAL3020 colour as standard.
EAE SYKCan operate under loadAre equipped with NH fuse holdersHave interlock mechanism
SYK 160 ASYK 250 ASYK 400 ASYK 630 A
Tap-off boxes can be equipped with any brandof switches, circuit breakers and etc.
Sample Order:Bolt-on / 630 A / IP-55 /5 Conductors
Sample Order:Plug-in / 400 A / IP-55 /5 Conductors
KBB 6351
KBP 4051
Bolt-onTap-off Boxes
Plug-inTap-off Boxes
Ce
l
abl
Gan
dPlat
e
on3
e)
(
s ids
Cabl
Glan
dPlate
e(o
n3s i
des)
KB
KBKBKB
B
BBB
1
246
6 5 0
5 5 00 5 03 5 0
KBKBKB
KB
PPP
P
124
5
6 5 05 5 00 5 0
0 5 0
Mat.Cable
Gland TypeOrderCode
InnerDiameter
(mm)Sheet RP0----
Sheet RP1 25M32
M40Sheet RP2 32
Sheet RP3 63Special
AL RP4 632xSpecial
AL RP5 184xM25
AL RP6 254xM32
AL RP7 324xM40
AL RP8 258xM32
Tap-off
Boxes
Standard
Gland
FuseSize
4
KBB 16
KBB 25
KBB 40
KBB 63
KBP 16
KBP 25
KBP 40KBP 50
520
670
670
700
520
670
670750
300
380
380
420
300
380
380420
190
240
255
255
190
240
255255
RP2
RP3
RP4
RP4
RP2
RP3
RP4RP4
NH00
NH 1
NH 2
NH 3
NH00
NH 1
NH 2NH 3
CA
B
L1L2 L3
N
L1L2L3
N
C
B
A
70
20
40
40
A
A
50
50
-
7/30/2019 Trunking Busbar E-Line_KB
25/33
25
E KBLINETap-off Boxesfor MCCB's
Please call us for non-standard tap-off boxes.
Special Cable Gland Plates
Sheet RPK0---- ----
Sheet RPK1 18M25
M32
M40
1xSpecial
Sheet
Sheet
Sheet
RPK2
RPK3
RPK4
25
32
63
* Tap-off boxes can be equipped with any brandof MCCB's.
Cable Gland Plates
Mat. CableGland Type OrderCode InnerDiameter(mm)
Sheet RP0---- ----
Mat.Cable
Gland TypeOrderCode
InnerDiameter
(mm)
Sheet RP1 25M32
M40Sheet RP2 32
Sheet RP3 63Special
AL RP4 632xSpecial
AL RP5 184xM25
AL RP6 254xM32
AL RP7 324xM40
AL RP8 258xM32
KB
BUSBAR TYPE
CONDUCTORPROTECTION DEGREE
RATED CURRENTBOX TYPE
IP-55-5
4 letken-05 letken-1
160 A-16250 A-25400 A-40630 A-63800 A-801000 A-10
Bolt on- BPlug in- P
CABLE GLAND PLATESSWITCH TYPE M- MCCB / B- Empty
Bolt-on
Tap-off Boxes
KBKBKBKB
KBKBKBKB
KBKBKBKB
KBKB
KBKB
BBBB
BBBB
BBBB
BB
BB
1246
1246
8811
88
11
6 5 0 - B15 5 0 - B10 5 0 - B13 5 0 - B1
6 5 05 5 0 - M10 5 0 - M13 5 0 - M1
- M1
0 4 0 - B10 5 0 - B10 4 0 - B10 5 0 - B1
0 4 00 5 0 - M1
0 4 0 - M10 5 0 - M1
- M1
Sample Order:Bolt-on / 630 A / IP-55 /
5 Conductors, empty tap off box
Sample Order:Bolt-on / 800 A / IP-55 /5 Conductors,empty tap off box
Sample Order:Plug-in / 400 A / IP-55 /5 Conductors, empty tap off box
KBB 6351 - B1
KBB 8051 - B1
KBP 4051 - B1
KBKBKBKB
KBKBKBKB
PPPP
PPPP
1246
1246
6 5 0 - B15 5 0 - B10 5 0 - B13 5 0 - B1
6 5 0 - M15 5 0 - M10 5 0 - M13 5 0 - M1
A(mm)
B(mm)
C(mm)
RPK3RPK4RP4RP4RP4RP4RPK3
RPK4RP4RP4
500500700700950950500
500700700
300300300300350350300
300300300
KBB 160KBB 250KBB 400KBB 630KBB 800KBB 1000KBP 160
KBP 250KBP 400KBP 630
220220220220305305220
220220220
Tap-offBoxes
StandardGland
70 40A
20 40A
Ce
lan
l
abl
Gd P
ate
(on3
de
)
si
s
L1 L2L3 N
C
B
A
50
Ce
lan
abl
Gd P
late
(on3
de
)
si
s
L1 L2L3 N
C
B
50
Ce
lan
l
abl
Gd P
ate
(on3
de
)
si
s
Plug-in
Tap-off Boxes
L1 L2L3 N
C
B
A
50
A
-
7/30/2019 Trunking Busbar E-Line_KB
26/33
Feeder Boxes
KB
BUSBAR TYPE
CONDUCTOR TYPE
BUSBAR CODE
PROTECTION DEGREE
TYPE
COMPONENT
UNPAINTED / PAINTED
C C40 4040 40
26
One way system,
4 conductors
One way system,
5 conductors
2 and 3 ways systems,
4 conductors
2 and 3 ways systems,
5 conductors
E KBLINE
250 250 250
B BB
D D D
A A A
150 150 150
200
250
B
D
A
150
200
Ampere Ratings
* New product group
Please call us for special applications or for applications with MCCB'sThe dimensions given above are minumum values.
1
2
3
4
KBA
A B C D
(mm) (mm) (mm) (mm) (mm)
800
1000
1250
16001600
2000
2500
3050
3100
4000
4250
5000
*
*
*
*
500
500
500
500
500500
500
500
500
700
700
700
700
520
520
520
520
520520
520
520
520
520
520
520
520
350
350
350
350
350550
550
550
550
765
765
765
945
350
350
350
350
350300
300
300
300
500
500
500
500
1
1
1
1
12
2
2
2
3
3
3
4
08
10
12
1316
20
25
27
30
40
41
5000
1000
1250
1600
2000
22502500
3000
3600
4250
4400
5300
6300
------
10
12
16
20
2325
30
36
42
44
53
63
---
*
*
*
B10
B11
L1L2
L3NPE
BO
L1L2
L3NPE
L1L2
L3NPE
L1
L2L3
NPE
Cable Gland Plates
Busbar
Housing Type
Cable
Gland Plate
Type
Aluminium
(Al)
Copper
(Cu)
Rated
Current
Rated
Current
Busbar
Code
Busbar
Code
Gland
Type
KBA 2750 - B10
KBA 2550 - BO
3650 - B11
Sample Order:3050 A, Aluminium, Bolt-on
Sample Order:3600 A, Copper, Bolt-on
Sample Order:2500 A, Aluminium, Bolt-on
- B 1 1
- B O
- B 1 0Feeder Box
Feeder Box B11
Central
Feeder Box BO
-
7/30/2019 Trunking Busbar E-Line_KB
27/33
Selection Feeder Boxes
front
27
E KBLINE
B11
B11
B10
B10
B11
B10
Application of
Feeder Boxes for the horizontal lines
Application of
Feeder Boxes for the vertical lines
In horizontal applications neutral conductoris considered to be lower conductor.
In vertical applications theneutral conductor shouldbe on the right side.
-
7/30/2019 Trunking Busbar E-Line_KB
28/33
BR4300400500600
200
BR40
40
UDD
IDD
IDY
300400-----2000
300400-----2000
300
400-----2000
UDYB 300400...1000
E KBLINEFixing Elements
ORDER CODE
LENGTH L (mm)
KB UT FIXING SET
Supports
Steel Dowel
Extension Unit
Theaded Rod
Steel Dowel
Extension Unit
Theaded Rod
IDT Fixing Element
Please call us for non-standard components.
* New product group
IDD
24
IDT
IDY
BR4
UDDL
IDDL
UDD
UDYB
UDYB
KB UT
IDY
28
15x
35
15x
35
155
105
L
L
105
155
350
350
350
400
450
450
500
550
600
650
750
800900
L
(mm)
800
1000
1250
1600
1600
2000
2500
3050
3200
4000
42505000
*
*
*
*
1000
1250
1600
2000
2250
2500
3000
3600
4250
4400
5300
6300------
08
10
12
13
16
20
25
27
30
40
4150
10
12
16
20
23
25
30
36
42
44
53
63---
*
*
*
Al
Conductor
Cu
Conductor
RatedCurrent
RatedCurrent
BusbarCode
BusbarCode
-
7/30/2019 Trunking Busbar E-Line_KB
29/33
PDD 300400...2000
PDDB
STK
UDY
STS
300400...1000
200300400
300400-----2000
200300400
L
29
E KBLINEFixing Elements
ORDER CODE
LENGTH L (mm)
Supports
Please call us for non-standard components.
BRA 12-05BRA 12-10
BRA 14-05BRA 14-10BRA 13BRA 13
BRA 9-3BRA 9-4
Threaded RodThreaded Rod (M10x1000)
Threaded Rod (M12x500)Threaded Rod (M12x1000)Exstension Unit (M10)Exstension Unit (M12)
Steel Dowel (M10)Steel Dowel (M12)
(M10x500)
Threaded Rods
ExstensionUnit
Steel Dowel
Diameter of thehole to be drilled
M10.....14M12.....16
UDD
STSSTS
TMP 5
UDY
PDD PDD
PDDB
PDDB
STK
IDD
STK
UDYL
L
L
L
L
-
7/30/2019 Trunking Busbar E-Line_KB
30/33
0
Certificate
E KBLINE
EC CONFORMITY CERTIFICATE
Product Group
Standard
Type Tests
This conformity certificate has been issued after running the below listed tests at laboratories.
1- Temperature-rise limits
2- Dielectric properties
3- Short-circuit strength
4- Effectiveness of the protective circuit
5- Clearances and creepage distances
6- Mechanical operation
7- Degree of protection
8- Electrical Characteristics
9- Structural Strength
10-Crushing resistance11-Resistance of insulating materials to abnormal heat
12-Flame Propagation
Manufacturer
E-Line KB Busbar Energy Distribution System
IEC 60439-2
EAE Elektrik A..
EAE Elektrik A..
Cakmakli Mahallesi, 2. Cadde, 119. Sokak, No:12 34522 Kirac-Hadimkoy-IstanbulTel: +90 (212) 886 23 90 Fax: +90 (212) 886 24 20 http://www.eae.com.tr
EAE Elektrik A..
Cakmakli Mahallesi, 2. Cadde, 119. Sokak,No:12 34522 Kirac-Hadimkoy-Istanbul
-
7/30/2019 Trunking Busbar E-Line_KB
31/33
31
Certificate
E KBLINE
-
7/30/2019 Trunking Busbar E-Line_KB
32/33
32
Product Overview
E KBLINE
800A...6300A
COMPACT BUSBAR PRODUCT OVERVIEW (E-LINE KB)
1-Standards & Certification:
Busbar system shall be designed and manufactured as per IEC 60439-2 standard. Each busbar rating shall have a separate type test certificate
from an independent internationally accredited laboratory.
Each product shall have a Type Label, which indicates the brand, type of the unit, conductor number and electrical details.
2-General Structure of Products:
Busbar system shall have Sandwich-Compact structure. Aluminium or Copper conductors shall be tin plated along the entire length. Housing
shall be 1, 50 mm galvanized steel or if required housing shall be RAL7038-Electrostatic painted.
2.1- Electrical Characteristics:
Busbar systems nominal insulation voltage shall be 1000V.
As per ampere rates, minimum short circuit values shall be like below;
For Aluminium Conductors;
- 800, 1000 and 1250A:1sec/rms-50kA, Peak-110kA
- 1600, 2000 and 2500A: 1sec/rms-100kA, Peak-220kA
- 3000A and above: 1sec/rms-120kA, Peak-264kA
Temperature rise shall be maximum 50K over 40C ambient temperature for both tin plated Aluminium and Copper conductor busbars.
2.2- Housing and Structure:
Busbar system shall have Sandwich-Compact structure.
Compact structure of the housing shall be provided by M6 screws applied at every 10 cm along the entire length.
Busbar system shall have all necessary accessories (elbows, offsets, panel-transformer connections, reductions, etc). Manufacturer shall supply
special dimensioned units in short time, if the project conditions requires.
For horizontal runs, a horizontal expansion unit shall be used at every 40m and expansion points of the building.
For vertical applications, a vertical expansion unit shall be used at every floor. Busbar system shall be rigidly fixed by supports at every floor.
2.3- Conductors:
Compact busbar system shall have Nickel and Tin-plated EC grade aluminium conductors (800-4250A). / Compact busbar system shall have Tin-
plated Electrolytic copper conductors (1000-6300A).
Busbar system shall have below number of conductors and phase configuration;
a)4 Conductors:(4 full size conductors + Housing (earthing) )
b)4 Conductors:(4 full size conductors + earth conductor + Housing)
c) 5 Conductors:(5 full size conductors + Housing (earth)
d) 5 Conductors:(5 full size conductors, 5th bar shall be used as clean earth + Housing
Neutral conductor shall have the same cross-section (100%) of phase conductors.Conductor and housing expansion differences shall be absorbed at the joints using Z shaped offsets.
2.4- Insulation:
For strong and long life time insulation system, there shall be 2 layers of extruded PP (Polypropylene) and 3 layers of B class polyester film
(Mylar) between neighbour conductors. Conductors shall be packed and placed into the housing without leaving any air gap for compact
(sandwich) structure.
2.5- Joint Structure:
Electrical and mechanical connection shall be made at joints by single bolt joint construction and each joint shall have two Belleville washers.
The joint shall be with direct overlapping of the conductors.
Insulators of the joint shall be manufactured of glass-reinforced polyester.
Joints shall be realized by a torque spanner (wrench) set at 80Nm.
To prevent the joints transportation damages, they shall be protected by plastic caps, which shall be removed before installation.
Joint bolt shall be locked from both sides (Bolt head and nut).
2.6- Protection:
Protection degree of the busbar system shall be IP55.
3-Tap Off Boxes:
Rating of plug-in tap off boxes shall start from160A and shall be up to and including 500A. Rating of Bolt-on tap off boxes shall start from160A and
shall be up to and including 1000A. Plug-in tap off boxes shall be installed, when the busbar line is energized.
Tap off boxes shall have an electrical interlock mechanism, which ensures that plug-in tap off box cannot be removed mechanically from the
busbar, when the switch is at ON position. Mechanical interlock mechanism shall prevent opening the door, when the switch is at ON position.
It shall be possible to install bolt-on tap off boxes up to 1000A to each joint of plug-in and bolt-on busbars. It shall be possible to install a bolt-on
tap off box only by removing the plastic contact distance pieces on the joints. The real contacts of the bolt-on tap off box shall be placed instead of
the contact distance pieces. The same bolt-on tap off box shall be installed to the joints of all busbar ratings without changing or adding any
pieces.
When the switch is at OFF position and the door is open, tap off box shall be at IP2X protection level. (There shall not be any accessible live part
in the box).
Tap Off boxes shall be suitable for any brand of MCCB.
Contacts of plug-in tap off box shall be silver-plated copper. Contacts of bolt-on tap off box shall be tin-plated copper.
While inserting the contacts of Plug-in tap off boxes, earth contact shall make first touch.
Any extra piece shall not be needed to install tap off boxes.Tap off boxes shall be manufactured of sheet steel and epoxy painted RAL 3020.
4-Installation and Commissioning:
Busbar systems shall be installed as per Single-Line drawings respect to required ampere rates and manufacturer installation guide (torque
values, lockers, etc.). Electrical installator shall run an insulation test after installation according to manufacturer's test procedures. The results of
the test shall be reported to the manufacturer. Minimum insulation value shall be 1Mohm.
Manufacturing facility of busbar systems shall have ISO 9001 and ISO 14001 certification.
For Copper Conductors;
- 1000, 1250, 1600, 2000 and 2250A:1sec/rms-50kA, Peak-105kA
- 2500, 3000, 3600 and 4250A: 1sec/rms-100kA, Peak-220kA
- 4400A and above: 1sec/rms-120kA, Peak-264kA
-
7/30/2019 Trunking Busbar E-Line_KB
33/33
Compact Busbar Distribution System
800...6300A
Plug-in Busbar Distribution System160...800A
Small Power Plug-in Busbar Distribution System100-160-225A
Plug-in Busbar Distribution System40-63A
Multi-Conductor Lighting Busbar System25-32-40A
Lighting Busbar System25-32-40A
Multi Conductor Trolley Busbar System35...250A
Underfloor Ducting Systems
Raised Floor Energy Distribution Systems25...63A
E-LINE KB
E-LINE KO
E-LINE MK
E-LINE KAP
E-LINE DL
E-LINE KAM
E-LINE TB
E-LINE DK
E-LINE DKY
E-LINE UK