TRUflex Series - Richardson RFPD | Home | Richardson RFPD Cor… · TRUflex...
Transcript of TRUflex Series - Richardson RFPD | Home | Richardson RFPD Cor… · TRUflex...
TRU Corporation offers an extensive line of flexible RF cable assembly and
connector solutions for applications that require RF high power/voltage
capability as well as reliable, high quality performance. Our long heritage in
high power design has made us a premier supplier in high power markets
including critical safety applications in the industrial equipment segment.
Specifying the optimal assembly for your application is simplified by the
broad selection of straight and right angle connector configurations and
interface options, as well as the extensive range of cable choices. Our cables
are specifically designed for their power capability and reliability. Our unique
TRUtie™ cable termination method provides superior mechanical retention
capabilities to eliminate the cable junction as a point of mechanical failure.
Our innovative Quick Connect/Disconnect interfaces: TRU-SQS®, TRU-QRM™
and TRU-QDS®, provide highly efficient and repeatable high power solutions
without the need for added hand tools to securely mate.
In addition to the broad range of standard configurations in this brochure,
TRU can also provide custom design solutions for your challenging
applications. Our experienced Application Engineering team is available
to personally answer all your technical questions.
Visit our website or contact your local RichardsonRFPD sales office to find
additional support and product information: trucorporation.com and
richardsonrfpd.com
• Broad range of connectorand cable combinations
• kW power handling capabilities
• Quick Connect/Disconnectinterface technology
• Test and adapter solutions available
• Experience in high power designand safety innovations
High PowerRF Cable Assemblies
TRUflex™ PWR Series
TRUflex PWR_trifold_051512_RFPD.qxd:Layout 1 5/16/12 3:35 PM Page 1
Maximum Mating VoltageInterface Frequency Cycles Rating
(GHz) (Minimum) (Vrms)
Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.
TRUflex™PWR Series TRUflex™PWR Series
Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.
TRUflex™PWR Series
trucorporation.com 1-800-262-9878trucorporation.com 1-800-262-9878
Cable Diameter (inches-nominal)
Cable Part Number TRU RG-393 TRU-450 TRU-500 TRU RG-217 TRU-560
Center Conductor (stranded/solid) 7 strand 7 strand 7 strand solid 7 strand
Cable Dielectric (material/construction) PTFE T-E/PTFE T-E/PTFE PE T-E/PTFE
Shields (number) 2 3 2 2 2
Shields (type) TPC round SPC flat and SPC flat and BC round SPC flat andround with round roundinterlayer
Cable Jacket (material/color) FEP brown FEP blue FEP blue PVC black PVC blue
Cable Operating Temperature (°C) -55 to 200 -65 to 200 -55 to 200 -40 to 85 -55 to 105
Cable Minimum Bend Radius Static (inches) 1.50 1.50 1.50 2.75 1.70
Cable Minimum Bend Radius Dynamic (inches) N/A 2.50 2.45 N/A 2.80
Frequency (maximum) 6 GHz 10 GHz 6 GHz 3 GHz 6 GHz
Impedance (Ohms-nominal) 50 50 50 50 50
Capacitance (pf/ft) 32.0 25.0 26.8 32.2 26.8
Shielding Effectiveness (dB minimum) -60 -90 -75 -60 -75
Velocity of Propagation (% nominal) 70 83 77 66 77
Weight (lbs/ft) 0.175 0.180 0.230 0.225 0.240
Power — See graph below — —
Voltage 10 kV 8 kV 12 kV 12 kV 12 kV
7-16 7.5 >500 2,700
LC 1.0 >500 3,000
SC 11.0 >500 1,000
HN 4.0 >500 1,500
MEIA-1625 3.0 >500 5,100
1-5/8 EIA 3.0 >500 5,100
TRU-SQS® 0.5 >2,500 4,000
TRU-QRM™ 1.0 >2,500 3,500
TRU-QDS® 6.0 >2,500 1,000
Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory. trucorporation.com 1-800-262-9878
Selecting a Connector InterfaceCoaxial Cable Reference Chart
0.450 0.4900.390 0.545 0.565
Sea Level 40°CMatched Load
Frequency (MHz)
1,000,000
100,000
10,000
1,000
100 1 10 100 1,000 10,000
RF Power Handling
CW
Power
(Watts)
— TRU RG-217— TRU RG-393— TRU-450— TRU-560— TRU-500
Sea Level 40°CMatched Load
Frequency (MHz)
100,000
10,000
1,000
100
100,000
10,000
1,000
1001 10 100 1,000 10,000
RF Power Handling
CW
Power
(Watts)
Sea Level 40°CMatched Load
Frequency (MHz)
10 100 1,000 10,000
RF Power Handling
CW
Power
(Watts)
— SC— HN— 7-16— LC—MEIA-1625
1-5/8 EIA
— TRU-QDS®
— TRU-QRM™
— TRU-SQS®
Provides positive mechanicalengagement and tightenvironmental seal whentorqued properly. Conformsto standard industryinterface specifications.
Direct mechanical attachmentusing screw/bolt fasteners.Requires tools. Robust connectionbut labor intensive.
Rapid connect/ disconnect byhand without the need for tooling.TRU-Redline™ indicator ensuresfull engagement. Provides safetymeasure in high powerenvironments. Can be used withinterlock safety switches.
Threaded
Mating Style Attributes
Flange Mount
Quick Connect/Disconnect
Connectors shown above are for reference only.
Specifying High Power RF Cable Assemblies
Instructions
To simplify the process of specifying an RF high power cable assembly, follow the step-by-step instructions below.
Please refer to the cable assembly below, which illustrates the various elements to specify.
Prior to selecting a cable and connectors please refer to the cable/connector selection matrix charts
to determine available combinations.
Additional reference data has been provided to facilitate the proper selection of components for your application
including frequency range and power handling. Ensure that the lower rating of either the connector interface
or coaxial cable will support the overall power specification for the assembly. It is important to note that several
factors such as temperature and altitude will potentially de-rate the overall power handling capability.
Specify each connectorinterface and
the configuration.(straight or right angle)
Specify coaxial cable required.
Reference coaxial cable chartfor attribute data.
Specify the length of the assembly.
Assemblies are generally measuredfrom end to end for straight
connectors, or from the centerlineof right angle connectors, as shown.
Specify any relevantmechanical/electricalor environmentalspecifications.
Identify any special markingrequirements and their location.
Standard marking isTRU part number and date code.
A C
D
Specify each connectorinterface and
the configuration.(straight or right angle)
A
B
Lengths ≤ 50 in (1,270 mm), tolerance = +/- 0.50 in (12.7 mm)
Lengths > 50 in (1,270 mm), tolerance = +/- 1% of length
SHRINK SLEEVESHRINK SLEEVE
E
Standard Cable Assembly Length Tolerances
TRUflex PWR_trifold_031212_TRU.qxd:Layout 1 3/12/12 1:30 PM Page 2
Maximum Mating VoltageInterface Frequency Cycles Rating
(GHz) (Minimum) (Vrms)
Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.
TRUflex™PWR Series TRUflex™PWR Series
Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.
TRUflex™PWR Series
trucorporation.com 1-800-262-9878trucorporation.com 1-800-262-9878
Cable Diameter (inches-nominal)
Cable Part Number TRU RG-393 TRU-450 TRU-500 TRU RG-217 TRU-560
Center Conductor (stranded/solid) 7 strand 7 strand 7 strand solid 7 strand
Cable Dielectric (material/construction) PTFE T-E/PTFE T-E/PTFE PE T-E/PTFE
Shields (number) 2 3 2 2 2
Shields (type) TPC round SPC flat and SPC flat and BC round SPC flat andround with round roundinterlayer
Cable Jacket (material/color) FEP brown FEP blue FEP blue PVC black PVC blue
Cable Operating Temperature (°C) -55 to 200 -65 to 200 -55 to 200 -40 to 85 -55 to 105
Cable Minimum Bend Radius Static (inches) 1.50 1.50 1.50 2.75 1.70
Cable Minimum Bend Radius Dynamic (inches) N/A 2.50 2.45 N/A 2.80
Frequency (maximum) 6 GHz 10 GHz 6 GHz 3 GHz 6 GHz
Impedance (Ohms-nominal) 50 50 50 50 50
Capacitance (pf/ft) 32.0 25.0 26.8 32.2 26.8
Shielding Effectiveness (dB minimum) -60 -90 -75 -60 -75
Velocity of Propagation (% nominal) 70 83 77 66 77
Weight (lbs/ft) 0.175 0.180 0.230 0.225 0.240
Power — See graph below — —
Voltage 10 kV 8 kV 12 kV 12 kV 12 kV
7-16 7.5 > 500 2,700
LC 1.0 > 500 3,000
SC 11.0 > 500 1,000
HN 4.0 > 500 1,500
MEIA-1625 3.0 > 500 5,100
1-5/8 EIA 3.0 > 500 5,100
TRU-SQS® 0.5 >2,500 4,000
TRU-QRM™ 1.0 >2,500 3,500
TRU-QDS® 6.0 >2,500 1,000
Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory. trucorporation.com 1-800-262-9878
Selecting a Connector InterfaceCoaxial Cable Reference Chart
0.450 0.4900.390 0.545 0.565
Sea Level 40°CMatched Load
Frequency (MHz)
1,000,000
100,000
10,000
1,000
100 1 10 100 1,000 10,000
RF Power Handling
CW
Pow
er(W
atts
)
— TRU RG-217— TRU RG-393— TRU-450— TRU-560— TRU-500
Ambient Temp 20°CMatched Load
Frequency (MHz)
100
10
1
0.11 10 100 1,000 10,000
Attenuation
dB
/100
ft
— TRU 500/560— TRU 450— TRU RG-217— TRU RG-393
Sea Level 40°CMatched Load
Frequency (MHz)
100,000
10,000
1,000
100
100,000
10,000
1,000
1001 10 100 1,000 10,0001 10 100 1,000 10,000
RF Power Handling
CW
Pow
er(W
atts
)
Sea Level 40°CMatched Load
Frequency (MHz)
RF Power Handling
CW
Pow
er(W
atts
)
— SC— HN— 7-16— LC— MEIA-1625
1-5/8 EIA
— TRU-QDS®
— TRU-QRM™
— TRU-SQS®
Provides positive mechanicalengagement and tightenvironmental seal whentorqued properly. Conformsto standard industryinterface specifications.
Direct mechanical attachmentusing screw/bolt fasteners.Requires tools. Robust connectionbut labor intensive.
Rapid connect/ disconnect byhand without the need for tooling.TRU-Redline™ indicator ensuresfull engagement. Provides safetymeasure in high powerenvironments. Can be used withinterlock safety switches.
Threaded
Mating Style Attributes
Flange Mount
Quick Connect/Disconnect
Connectors shown above are for reference only.
Specifying High Power RF Cable Assemblies
Instructions
To simplify the process of specifying an RF high power cable assembly, follow the step-by-step instructions below.
Please refer to the cable assembly below, which illustrates the various elements to specify.
Prior to selecting a cable and connectors please refer to the cable/connector selection matrix charts
to determine available combinations.
Additional reference data has been provided to facilitate the proper selection of components for your application
including frequency range and power handling. Ensure that the lower rating of either the connector interface
or coaxial cable will support the overall power specification for the assembly. It is important to note that several
factors such as temperature and altitude will potentially de-rate the overall power handling capability.
Specify each connectorinterface and
the configuration.(straight or right angle)
Specify coaxial cable required.
Reference coaxial cable chartfor attribute data.
Specify the length of the assembly.
Assemblies are generally measuredfrom end to end for straight
connectors, or from the centerlineof right angle connectors, as shown.
Specify any relevantmechanical/electricalor environmentalspecifications.
Identify any special markingrequirements and their location.
Standard marking isTRU part number and date code.
A C
D
Specify each connectorinterface and
the configuration.(straight or right angle)
A
B
Lengths ≤ 50 in (1,270 mm), tolerance = +/- 0.50 in (12.7 mm)
Lengths > 50 in (1,270 mm), tolerance = +/- 1% of length
SHRINK SLEEVESHRINK SLEEVE
E
Standard Cable Assembly Length Tolerances
TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 5/16/12 3:15 PM Page 2
Maximum Mating VoltageInterface Frequency Cycles Rating
(GHz) (Minimum) (Vrms)
Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.
TRUflex™PWR Series TRUflex™PWR Series
Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.
TRUflex™PWR Series
trucorporation.com 1-800-262-9878trucorporation.com 1-800-262-9878
Cable Diameter (inches-nominal)
Cable Part Number TRU RG-393 TRU-450 TRU-500 TRU RG-217 TRU-560
Center Conductor (stranded/solid) 7 strand 7 strand 7 strand solid 7 strand
Cable Dielectric (material/construction) PTFE T-E/PTFE T-E/PTFE PE T-E/PTFE
Shields (number) 2 3 2 2 2
Shields (type) TPC round SPC flat and SPC flat and BC round SPC flat andround with round roundinterlayer
Cable Jacket (material/color) FEP brown FEP blue FEP blue PVC black PVC blue
Cable Operating Temperature (°C) -55 to 200 -65 to 200 -55 to 200 -40 to 85 -55 to 105
Cable Minimum Bend Radius Static (inches) 1.50 1.50 1.50 2.75 1.70
Cable Minimum Bend Radius Dynamic (inches) N/A 2.50 2.45 N/A 2.80
Frequency (maximum) 6 GHz 10 GHz 6 GHz 3 GHz 6 GHz
Impedance (Ohms-nominal) 50 50 50 50 50
Capacitance (pf/ft) 32.0 25.0 26.8 32.2 26.8
Shielding Effectiveness (dB minimum) -60 -90 -75 -60 -75
Velocity of Propagation (% nominal) 70 83 77 66 77
Weight (lbs/ft) 0.175 0.180 0.230 0.225 0.240
Power — See graph below — —
Voltage 10 kV 8 kV 12 kV 12 kV 12 kV
7-16 7.5 > 500 2,700
LC 1.0 > 500 3,000
SC 11.0 > 500 1,000
HN 4.0 > 500 1,500
MEIA-1625 3.0 > 500 5,100
1-5/8 EIA 3.0 > 500 5,100
TRU-SQS® 0.5 >2,500 4,000
TRU-QRM™ 1.0 >2,500 3,500
TRU-QDS® 6.0 >2,500 1,000
Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory. trucorporation.com 1-800-262-9878
Selecting a Connector InterfaceCoaxial Cable Reference Chart
0.450 0.4900.390 0.545 0.565
Sea Level 40°CMatched Load
Frequency (MHz)
1,000,000
100,000
10,000
1,000
100 1 10 100 1,000 10,000
RF Power Handling
CW
Pow
er(W
atts
)
— TRU RG-217— TRU RG-393— TRU-450— TRU-560— TRU-500
Ambient Temp 20°CMatched Load
Frequency (MHz)
100
10
1
0.11 10 100 1,000 10,000
Attenuation
dB
/100
ft
— TRU 500/560— TRU 450— TRU RG-217— TRU RG-393
Sea Level 40°CMatched Load
Frequency (MHz)
100,000
10,000
1,000
100
100,000
10,000
1,000
1001 10 100 1,000 10,0001 10 100 1,000 10,000
RF Power Handling
CW
Pow
er(W
atts
)
Sea Level 40°CMatched Load
Frequency (MHz)
RF Power Handling
CW
Pow
er(W
atts
)
— SC— HN— 7-16— LC— MEIA-1625
1-5/8 EIA
— TRU-QDS®
— TRU-QRM™
— TRU-SQS®
Provides positive mechanicalengagement and tightenvironmental seal whentorqued properly. Conformsto standard industryinterface specifications.
Direct mechanical attachmentusing screw/bolt fasteners.Requires tools. Robust connectionbut labor intensive.
Rapid connect/ disconnect byhand without the need for tooling.TRU-Redline™ indicator ensuresfull engagement. Provides safetymeasure in high powerenvironments. Can be used withinterlock safety switches.
Threaded
Mating Style Attributes
Flange Mount
Quick Connect/Disconnect
Connectors shown above are for reference only.
Specifying High Power RF Cable Assemblies
Instructions
To simplify the process of specifying an RF high power cable assembly, follow the step-by-step instructions below.
Please refer to the cable assembly below, which illustrates the various elements to specify.
Prior to selecting a cable and connectors please refer to the cable/connector selection matrix charts
to determine available combinations.
Additional reference data has been provided to facilitate the proper selection of components for your application
including frequency range and power handling. Ensure that the lower rating of either the connector interface
or coaxial cable will support the overall power specification for the assembly. It is important to note that several
factors such as temperature and altitude will potentially de-rate the overall power handling capability.
Specify each connectorinterface and
the configuration.(straight or right angle)
Specify coaxial cable required.
Reference coaxial cable chartfor attribute data.
Specify the length of the assembly.
Assemblies are generally measuredfrom end to end for straight
connectors, or from the centerlineof right angle connectors, as shown.
Specify any relevantmechanical/electricalor environmentalspecifications.
Identify any special markingrequirements and their location.
Standard marking isTRU part number and date code.
A C
D
Specify each connectorinterface and
the configuration.(straight or right angle)
A
B
Lengths ≤ 50 in (1,270 mm), tolerance = +/- 0.50 in (12.7 mm)
Lengths > 50 in (1,270 mm), tolerance = +/- 1% of length
SHRINK SLEEVESHRINK SLEEVE
E
Standard Cable Assembly Length Tolerances
TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 5/16/12 3:15 PM Page 2
TRU Corporation offers an extensive line of flexible RF cable assembly and
connector solutions for applications that require RF high power/voltage
capability as well as reliable, high quality performance. Our long heritage in
high power design has made us a premier supplier in high power markets
including critical safety applications in the industrial equipment segment.
Specifying the optimal assembly for your application is simplified by the
broad selection of straight and right angle connector configurations and
interface options, as well as the extensive range of cable choices. Our cables
are specifically designed for their power capability and reliability. Our unique
TRUtie™ cable termination method provides superior mechanical retention
capabilities to eliminate the cable junction as a point of mechanical failure.
Our innovative Quick Connect/Disconnect interfaces: TRU-SQS®, TRU-QRM™
and TRU-QDS®, provide highly efficient and repeatable high power solutions
without the need for added hand tools to securely mate.
In addition to the broad range of standard configurations in this brochure,
TRU can also provide custom design solutions for your challenging
applications. Our experienced Application Engineering team is available
to personally answer all your technical questions.
Visit our website to find additional support and product information:
trucorporation.com
trucorporation.com 1-800-262-9878Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.
TRUflex™PWR Series
TRU Corporation,Peabody, MA 01960 USA
1 800 262-9878(1 800 COAX-TRU)978 532-0775022012-003
To request literature: [email protected]
trucorporation.com
TRUflex™PWR Series
Threaded and Flange Mount Connector Configurations
TRU offers a broad range of standard high power cable connector designs and configurations to provide
the maximum flexibility for your design. In addition to those shown below, TRU can provide custom designs
and features per your specification. TRU also offers a broad range of panel mount receptacles with
high power/voltage capability and application specific launch geometries.
• Broad range of connectorand cable combinations
• kW power handling capabilities
• Quick Connect/Disconnectinterface technology
• Test and adapter solutions available
• Experience in high power designand safety innovations
High PowerRF Cable Assemblies
TRUflex™PWR Series
SC Straight Plug
SC Right AnglePlug
1-5/8 EIAStraight Plug
MEIA-1625Straight Plug
LC Right AnglePlug
7-16 Right AnglePlug
LC Straight Plug7-16 Straight Plug
2.45"
1.40"
3.75"
2.38"
4.35" 1.64"
3.50"
2.87"
1.62"
0.50"
2.75"
1.25"
3.10"
0.93"
3.06" 0.5"
1.63"
1.26"
1.17"
Dimensions shown are reference only.
Dimensions shown are reference only.
TRU Corporation Quick-Connect/Disconnect RF interface provides reliable mating with fast connect/disconnect
capability. These interfaces feature a positive locking mechanism employing a spring-loaded sleeve on the male
plug that is drawn back to let self-contained bearings “click” into grooves on the mating female receptacle, and
slide forward. A fully mated and safe condition is visually represented with full coverage of our TRU-Redline™
indicator. These designs provide exceptionally fast and reliable hand mating that will not vibrate loose.
Quick Connect/Disconnect Connector Configurations
TRU-SQS® spring-loaded sleeveis retracted and interfaces
engaged. Note TRU-Redline™indicator is still visible untilsleeve is released and a fullymated condition is present.
TRU-SQS® interfaces shownin a fully mated condition.
The right angle assembly canbe mated at any position alonga 360° arc offering optimalflexibility in the assembly
orientation.
TRU-SQS® right angle, cable plugand panel mount receptacle shown
in unmated condition.
TRU-SQS® Straight Plug TRU-QRM™ Straight Plug TRU-QDS® Straight Plug
TRU-SQS®
Right AnglePlug
TRU-QRM™Right AnglePlug
TRU-QDS®
Right AnglePlug
3.40" 2.70" 2.90"
1.70" 1.50" 1.13"
2.40"
2.00"
2.80"
1.90"
2.20"
1.50"
TRUflex PWR_trifold_031212_TRU.qxd:Layout 1 3/12/12 5:34 PM Page 1
TRUflex™PWR Series
TRU Corporation,Peabody, MA 01960 USA
1 800 262-9878(1 800 COAX-TRU)978 532-0775052012-005
To request literature: [email protected]
trucorporation.com
Threaded and Flange Mount Connector Configurations
TRU offers a broad range of standard high power cable connector designs and configurations to provide
the maximum flexibility for your design. In addition to those shown below, TRU can provide custom designs
and features per your specification. TRU also offers a broad range of panel mount receptacles with
high power/voltage capability and application specific launch geometries.
SC Straight Plug
SC Right AnglePlug
1-5/8 EIAStraight Plug
MEIA-1625Straight Plug
LC Right AnglePlug
7-16 Right AnglePlug
LC Straight Plug7-16 Straight Plug
2.45"
1.40"
3.75"
2.38"
4.35" 1.64"
3.50"
2.87"
1.62"
0.50"
2.75"
1.25"
3.10"
0.93"
3.06" 0.5"
1.63"
1.26"
1.17"
Dimensions shown are reference only.
Corporate HeadquartersRichardson RFPD40W267 Keslinger RoadP.O. Box 307LaFox, IL 60147-0307 USAToll Free: 800-737-6937Phone: 630-208-2700Fax: 630-208-2662Internet: www.richardsonrfpd.comEmail: [email protected]
TRUflex PWR_trifold_051512_RFPD.qxd:Layout 1 5/16/12 3:39 PM Page 1