TRUflex Series - Richardson RFPD | Home | Richardson RFPD Cor… · TRUflex...

6
TRU Corporation offers an extensive line of flexible RF cable assembly and connector solutions for applications that require RF high power/voltage capability as well as reliable, high quality performance. Our long heritage in high power design has made us a premier supplier in high power markets including critical safety applications in the industrial equipment segment. Specifying the optimal assembly for your application is simplified by the broad selection of straight and right angle connector configurations and interface options, as well as the extensive range of cable choices. Our cables are specifically designed for their power capability and reliability. Our unique TRUtie cable termination method provides superior mechanical retention capabilities to eliminate the cable junction as a point of mechanical failure. Our innovative Quick Connect/Disconnect interfaces: TRU-SQS ® , TRU-QRM and TRU-QDS ® , provide highly efficient and repeatable high power solutions without the need for added hand tools to securely mate. In addition to the broad range of standard configurations in this brochure, TRU can also provide custom design solutions for your challenging applications. Our experienced Application Engineering team is available to personally answer all your technical questions. Visit our website or contact your local RichardsonRFPD sales office to find additional support and product information: trucorporation.com and richardsonrfpd.com • Broad range of connector and cable combinations • kW power handling capabilities • Quick Connect/Disconnect interface technology • Test and adapter solutions available • Experience in high power design and safety innovations High Power RF Cable Assemblies TRUflex PWR Series

Transcript of TRUflex Series - Richardson RFPD | Home | Richardson RFPD Cor… · TRUflex...

Page 1: TRUflex Series - Richardson RFPD | Home | Richardson RFPD Cor… · TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 5/16/12 3:15 PM Page 2. Maximum Mating Voltage Interface Frequency

TRU Corporation offers an extensive line of flexible RF cable assembly and

connector solutions for applications that require RF high power/voltage

capability as well as reliable, high quality performance. Our long heritage in

high power design has made us a premier supplier in high power markets

including critical safety applications in the industrial equipment segment.

Specifying the optimal assembly for your application is simplified by the

broad selection of straight and right angle connector configurations and

interface options, as well as the extensive range of cable choices. Our cables

are specifically designed for their power capability and reliability. Our unique

TRUtie™ cable termination method provides superior mechanical retention

capabilities to eliminate the cable junction as a point of mechanical failure.

Our innovative Quick Connect/Disconnect interfaces: TRU-SQS®, TRU-QRM™

and TRU-QDS®, provide highly efficient and repeatable high power solutions

without the need for added hand tools to securely mate.

In addition to the broad range of standard configurations in this brochure,

TRU can also provide custom design solutions for your challenging

applications. Our experienced Application Engineering team is available

to personally answer all your technical questions.

Visit our website or contact your local RichardsonRFPD sales office to find

additional support and product information: trucorporation.com and

richardsonrfpd.com

• Broad range of connectorand cable combinations

• kW power handling capabilities

• Quick Connect/Disconnectinterface technology

• Test and adapter solutions available

• Experience in high power designand safety innovations

High PowerRF Cable Assemblies

TRUflex™ PWR Series

TRUflex PWR_trifold_051512_RFPD.qxd:Layout 1 5/16/12 3:35 PM Page 1

Page 2: TRUflex Series - Richardson RFPD | Home | Richardson RFPD Cor… · TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 5/16/12 3:15 PM Page 2. Maximum Mating Voltage Interface Frequency

Maximum Mating VoltageInterface Frequency Cycles Rating

(GHz) (Minimum) (Vrms)

Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.

TRUflex™PWR Series TRUflex™PWR Series

Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.

TRUflex™PWR Series

trucorporation.com 1-800-262-9878trucorporation.com 1-800-262-9878

Cable Diameter (inches-nominal)

Cable Part Number TRU RG-393 TRU-450 TRU-500 TRU RG-217 TRU-560

Center Conductor (stranded/solid) 7 strand 7 strand 7 strand solid 7 strand

Cable Dielectric (material/construction) PTFE T-E/PTFE T-E/PTFE PE T-E/PTFE

Shields (number) 2 3 2 2 2

Shields (type) TPC round SPC flat and SPC flat and BC round SPC flat andround with round roundinterlayer

Cable Jacket (material/color) FEP brown FEP blue FEP blue PVC black PVC blue

Cable Operating Temperature (°C) -55 to 200 -65 to 200 -55 to 200 -40 to 85 -55 to 105

Cable Minimum Bend Radius Static (inches) 1.50 1.50 1.50 2.75 1.70

Cable Minimum Bend Radius Dynamic (inches) N/A 2.50 2.45 N/A 2.80

Frequency (maximum) 6 GHz 10 GHz 6 GHz 3 GHz 6 GHz

Impedance (Ohms-nominal) 50 50 50 50 50

Capacitance (pf/ft) 32.0 25.0 26.8 32.2 26.8

Shielding Effectiveness (dB minimum) -60 -90 -75 -60 -75

Velocity of Propagation (% nominal) 70 83 77 66 77

Weight (lbs/ft) 0.175 0.180 0.230 0.225 0.240

Power — See graph below — —

Voltage 10 kV 8 kV 12 kV 12 kV 12 kV

7-16 7.5 >500 2,700

LC 1.0 >500 3,000

SC 11.0 >500 1,000

HN 4.0 >500 1,500

MEIA-1625 3.0 >500 5,100

1-5/8 EIA 3.0 >500 5,100

TRU-SQS® 0.5 >2,500 4,000

TRU-QRM™ 1.0 >2,500 3,500

TRU-QDS® 6.0 >2,500 1,000

Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory. trucorporation.com 1-800-262-9878

Selecting a Connector InterfaceCoaxial Cable Reference Chart

0.450 0.4900.390 0.545 0.565

Sea Level 40°CMatched Load

Frequency (MHz)

1,000,000

100,000

10,000

1,000

100 1 10 100 1,000 10,000

RF Power Handling

CW

Power

(Watts)

— TRU RG-217— TRU RG-393— TRU-450— TRU-560— TRU-500

Sea Level 40°CMatched Load

Frequency (MHz)

100,000

10,000

1,000

100

100,000

10,000

1,000

1001 10 100 1,000 10,000

RF Power Handling

CW

Power

(Watts)

Sea Level 40°CMatched Load

Frequency (MHz)

10 100 1,000 10,000

RF Power Handling

CW

Power

(Watts)

— SC— HN— 7-16— LC—MEIA-1625

1-5/8 EIA

— TRU-QDS®

— TRU-QRM™

— TRU-SQS®

Provides positive mechanicalengagement and tightenvironmental seal whentorqued properly. Conformsto standard industryinterface specifications.

Direct mechanical attachmentusing screw/bolt fasteners.Requires tools. Robust connectionbut labor intensive.

Rapid connect/ disconnect byhand without the need for tooling.TRU-Redline™ indicator ensuresfull engagement. Provides safetymeasure in high powerenvironments. Can be used withinterlock safety switches.

Threaded

Mating Style Attributes

Flange Mount

Quick Connect/Disconnect

Connectors shown above are for reference only.

Specifying High Power RF Cable Assemblies

Instructions

To simplify the process of specifying an RF high power cable assembly, follow the step-by-step instructions below.

Please refer to the cable assembly below, which illustrates the various elements to specify.

Prior to selecting a cable and connectors please refer to the cable/connector selection matrix charts

to determine available combinations.

Additional reference data has been provided to facilitate the proper selection of components for your application

including frequency range and power handling. Ensure that the lower rating of either the connector interface

or coaxial cable will support the overall power specification for the assembly. It is important to note that several

factors such as temperature and altitude will potentially de-rate the overall power handling capability.

Specify each connectorinterface and

the configuration.(straight or right angle)

Specify coaxial cable required.

Reference coaxial cable chartfor attribute data.

Specify the length of the assembly.

Assemblies are generally measuredfrom end to end for straight

connectors, or from the centerlineof right angle connectors, as shown.

Specify any relevantmechanical/electricalor environmentalspecifications.

Identify any special markingrequirements and their location.

Standard marking isTRU part number and date code.

A C

D

Specify each connectorinterface and

the configuration.(straight or right angle)

A

B

Lengths ≤ 50 in (1,270 mm), tolerance = +/- 0.50 in (12.7 mm)

Lengths > 50 in (1,270 mm), tolerance = +/- 1% of length

SHRINK SLEEVESHRINK SLEEVE

E

Standard Cable Assembly Length Tolerances

TRUflex PWR_trifold_031212_TRU.qxd:Layout 1 3/12/12 1:30 PM Page 2

Page 3: TRUflex Series - Richardson RFPD | Home | Richardson RFPD Cor… · TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 5/16/12 3:15 PM Page 2. Maximum Mating Voltage Interface Frequency

Maximum Mating VoltageInterface Frequency Cycles Rating

(GHz) (Minimum) (Vrms)

Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.

TRUflex™PWR Series TRUflex™PWR Series

Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.

TRUflex™PWR Series

trucorporation.com 1-800-262-9878trucorporation.com 1-800-262-9878

Cable Diameter (inches-nominal)

Cable Part Number TRU RG-393 TRU-450 TRU-500 TRU RG-217 TRU-560

Center Conductor (stranded/solid) 7 strand 7 strand 7 strand solid 7 strand

Cable Dielectric (material/construction) PTFE T-E/PTFE T-E/PTFE PE T-E/PTFE

Shields (number) 2 3 2 2 2

Shields (type) TPC round SPC flat and SPC flat and BC round SPC flat andround with round roundinterlayer

Cable Jacket (material/color) FEP brown FEP blue FEP blue PVC black PVC blue

Cable Operating Temperature (°C) -55 to 200 -65 to 200 -55 to 200 -40 to 85 -55 to 105

Cable Minimum Bend Radius Static (inches) 1.50 1.50 1.50 2.75 1.70

Cable Minimum Bend Radius Dynamic (inches) N/A 2.50 2.45 N/A 2.80

Frequency (maximum) 6 GHz 10 GHz 6 GHz 3 GHz 6 GHz

Impedance (Ohms-nominal) 50 50 50 50 50

Capacitance (pf/ft) 32.0 25.0 26.8 32.2 26.8

Shielding Effectiveness (dB minimum) -60 -90 -75 -60 -75

Velocity of Propagation (% nominal) 70 83 77 66 77

Weight (lbs/ft) 0.175 0.180 0.230 0.225 0.240

Power — See graph below — —

Voltage 10 kV 8 kV 12 kV 12 kV 12 kV

7-16 7.5 > 500 2,700

LC 1.0 > 500 3,000

SC 11.0 > 500 1,000

HN 4.0 > 500 1,500

MEIA-1625 3.0 > 500 5,100

1-5/8 EIA 3.0 > 500 5,100

TRU-SQS® 0.5 >2,500 4,000

TRU-QRM™ 1.0 >2,500 3,500

TRU-QDS® 6.0 >2,500 1,000

Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory. trucorporation.com 1-800-262-9878

Selecting a Connector InterfaceCoaxial Cable Reference Chart

0.450 0.4900.390 0.545 0.565

Sea Level 40°CMatched Load

Frequency (MHz)

1,000,000

100,000

10,000

1,000

100 1 10 100 1,000 10,000

RF Power Handling

CW

Pow

er(W

atts

)

— TRU RG-217— TRU RG-393— TRU-450— TRU-560— TRU-500

Ambient Temp 20°CMatched Load

Frequency (MHz)

100

10

1

0.11 10 100 1,000 10,000

Attenuation

dB

/100

ft

— TRU 500/560— TRU 450— TRU RG-217— TRU RG-393

Sea Level 40°CMatched Load

Frequency (MHz)

100,000

10,000

1,000

100

100,000

10,000

1,000

1001 10 100 1,000 10,0001 10 100 1,000 10,000

RF Power Handling

CW

Pow

er(W

atts

)

Sea Level 40°CMatched Load

Frequency (MHz)

RF Power Handling

CW

Pow

er(W

atts

)

— SC— HN— 7-16— LC— MEIA-1625

1-5/8 EIA

— TRU-QDS®

— TRU-QRM™

— TRU-SQS®

Provides positive mechanicalengagement and tightenvironmental seal whentorqued properly. Conformsto standard industryinterface specifications.

Direct mechanical attachmentusing screw/bolt fasteners.Requires tools. Robust connectionbut labor intensive.

Rapid connect/ disconnect byhand without the need for tooling.TRU-Redline™ indicator ensuresfull engagement. Provides safetymeasure in high powerenvironments. Can be used withinterlock safety switches.

Threaded

Mating Style Attributes

Flange Mount

Quick Connect/Disconnect

Connectors shown above are for reference only.

Specifying High Power RF Cable Assemblies

Instructions

To simplify the process of specifying an RF high power cable assembly, follow the step-by-step instructions below.

Please refer to the cable assembly below, which illustrates the various elements to specify.

Prior to selecting a cable and connectors please refer to the cable/connector selection matrix charts

to determine available combinations.

Additional reference data has been provided to facilitate the proper selection of components for your application

including frequency range and power handling. Ensure that the lower rating of either the connector interface

or coaxial cable will support the overall power specification for the assembly. It is important to note that several

factors such as temperature and altitude will potentially de-rate the overall power handling capability.

Specify each connectorinterface and

the configuration.(straight or right angle)

Specify coaxial cable required.

Reference coaxial cable chartfor attribute data.

Specify the length of the assembly.

Assemblies are generally measuredfrom end to end for straight

connectors, or from the centerlineof right angle connectors, as shown.

Specify any relevantmechanical/electricalor environmentalspecifications.

Identify any special markingrequirements and their location.

Standard marking isTRU part number and date code.

A C

D

Specify each connectorinterface and

the configuration.(straight or right angle)

A

B

Lengths ≤ 50 in (1,270 mm), tolerance = +/- 0.50 in (12.7 mm)

Lengths > 50 in (1,270 mm), tolerance = +/- 1% of length

SHRINK SLEEVESHRINK SLEEVE

E

Standard Cable Assembly Length Tolerances

TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 5/16/12 3:15 PM Page 2

Page 4: TRUflex Series - Richardson RFPD | Home | Richardson RFPD Cor… · TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 5/16/12 3:15 PM Page 2. Maximum Mating Voltage Interface Frequency

Maximum Mating VoltageInterface Frequency Cycles Rating

(GHz) (Minimum) (Vrms)

Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.

TRUflex™PWR Series TRUflex™PWR Series

Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.

TRUflex™PWR Series

trucorporation.com 1-800-262-9878trucorporation.com 1-800-262-9878

Cable Diameter (inches-nominal)

Cable Part Number TRU RG-393 TRU-450 TRU-500 TRU RG-217 TRU-560

Center Conductor (stranded/solid) 7 strand 7 strand 7 strand solid 7 strand

Cable Dielectric (material/construction) PTFE T-E/PTFE T-E/PTFE PE T-E/PTFE

Shields (number) 2 3 2 2 2

Shields (type) TPC round SPC flat and SPC flat and BC round SPC flat andround with round roundinterlayer

Cable Jacket (material/color) FEP brown FEP blue FEP blue PVC black PVC blue

Cable Operating Temperature (°C) -55 to 200 -65 to 200 -55 to 200 -40 to 85 -55 to 105

Cable Minimum Bend Radius Static (inches) 1.50 1.50 1.50 2.75 1.70

Cable Minimum Bend Radius Dynamic (inches) N/A 2.50 2.45 N/A 2.80

Frequency (maximum) 6 GHz 10 GHz 6 GHz 3 GHz 6 GHz

Impedance (Ohms-nominal) 50 50 50 50 50

Capacitance (pf/ft) 32.0 25.0 26.8 32.2 26.8

Shielding Effectiveness (dB minimum) -60 -90 -75 -60 -75

Velocity of Propagation (% nominal) 70 83 77 66 77

Weight (lbs/ft) 0.175 0.180 0.230 0.225 0.240

Power — See graph below — —

Voltage 10 kV 8 kV 12 kV 12 kV 12 kV

7-16 7.5 > 500 2,700

LC 1.0 > 500 3,000

SC 11.0 > 500 1,000

HN 4.0 > 500 1,500

MEIA-1625 3.0 > 500 5,100

1-5/8 EIA 3.0 > 500 5,100

TRU-SQS® 0.5 >2,500 4,000

TRU-QRM™ 1.0 >2,500 3,500

TRU-QDS® 6.0 >2,500 1,000

Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory. trucorporation.com 1-800-262-9878

Selecting a Connector InterfaceCoaxial Cable Reference Chart

0.450 0.4900.390 0.545 0.565

Sea Level 40°CMatched Load

Frequency (MHz)

1,000,000

100,000

10,000

1,000

100 1 10 100 1,000 10,000

RF Power Handling

CW

Pow

er(W

atts

)

— TRU RG-217— TRU RG-393— TRU-450— TRU-560— TRU-500

Ambient Temp 20°CMatched Load

Frequency (MHz)

100

10

1

0.11 10 100 1,000 10,000

Attenuation

dB

/100

ft

— TRU 500/560— TRU 450— TRU RG-217— TRU RG-393

Sea Level 40°CMatched Load

Frequency (MHz)

100,000

10,000

1,000

100

100,000

10,000

1,000

1001 10 100 1,000 10,0001 10 100 1,000 10,000

RF Power Handling

CW

Pow

er(W

atts

)

Sea Level 40°CMatched Load

Frequency (MHz)

RF Power Handling

CW

Pow

er(W

atts

)

— SC— HN— 7-16— LC— MEIA-1625

1-5/8 EIA

— TRU-QDS®

— TRU-QRM™

— TRU-SQS®

Provides positive mechanicalengagement and tightenvironmental seal whentorqued properly. Conformsto standard industryinterface specifications.

Direct mechanical attachmentusing screw/bolt fasteners.Requires tools. Robust connectionbut labor intensive.

Rapid connect/ disconnect byhand without the need for tooling.TRU-Redline™ indicator ensuresfull engagement. Provides safetymeasure in high powerenvironments. Can be used withinterlock safety switches.

Threaded

Mating Style Attributes

Flange Mount

Quick Connect/Disconnect

Connectors shown above are for reference only.

Specifying High Power RF Cable Assemblies

Instructions

To simplify the process of specifying an RF high power cable assembly, follow the step-by-step instructions below.

Please refer to the cable assembly below, which illustrates the various elements to specify.

Prior to selecting a cable and connectors please refer to the cable/connector selection matrix charts

to determine available combinations.

Additional reference data has been provided to facilitate the proper selection of components for your application

including frequency range and power handling. Ensure that the lower rating of either the connector interface

or coaxial cable will support the overall power specification for the assembly. It is important to note that several

factors such as temperature and altitude will potentially de-rate the overall power handling capability.

Specify each connectorinterface and

the configuration.(straight or right angle)

Specify coaxial cable required.

Reference coaxial cable chartfor attribute data.

Specify the length of the assembly.

Assemblies are generally measuredfrom end to end for straight

connectors, or from the centerlineof right angle connectors, as shown.

Specify any relevantmechanical/electricalor environmentalspecifications.

Identify any special markingrequirements and their location.

Standard marking isTRU part number and date code.

A C

D

Specify each connectorinterface and

the configuration.(straight or right angle)

A

B

Lengths ≤ 50 in (1,270 mm), tolerance = +/- 0.50 in (12.7 mm)

Lengths > 50 in (1,270 mm), tolerance = +/- 1% of length

SHRINK SLEEVESHRINK SLEEVE

E

Standard Cable Assembly Length Tolerances

TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 5/16/12 3:15 PM Page 2

Page 5: TRUflex Series - Richardson RFPD | Home | Richardson RFPD Cor… · TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 5/16/12 3:15 PM Page 2. Maximum Mating Voltage Interface Frequency

TRU Corporation offers an extensive line of flexible RF cable assembly and

connector solutions for applications that require RF high power/voltage

capability as well as reliable, high quality performance. Our long heritage in

high power design has made us a premier supplier in high power markets

including critical safety applications in the industrial equipment segment.

Specifying the optimal assembly for your application is simplified by the

broad selection of straight and right angle connector configurations and

interface options, as well as the extensive range of cable choices. Our cables

are specifically designed for their power capability and reliability. Our unique

TRUtie™ cable termination method provides superior mechanical retention

capabilities to eliminate the cable junction as a point of mechanical failure.

Our innovative Quick Connect/Disconnect interfaces: TRU-SQS®, TRU-QRM™

and TRU-QDS®, provide highly efficient and repeatable high power solutions

without the need for added hand tools to securely mate.

In addition to the broad range of standard configurations in this brochure,

TRU can also provide custom design solutions for your challenging

applications. Our experienced Application Engineering team is available

to personally answer all your technical questions.

Visit our website to find additional support and product information:

trucorporation.com

trucorporation.com 1-800-262-9878Specifications subject to change without notice. For additionalspecifications or other products, visit us online or contact the factory.

TRUflex™PWR Series

TRU Corporation,Peabody, MA 01960 USA

1 800 262-9878(1 800 COAX-TRU)978 532-0775022012-003

To request literature: [email protected]

trucorporation.com

TRUflex™PWR Series

Threaded and Flange Mount Connector Configurations

TRU offers a broad range of standard high power cable connector designs and configurations to provide

the maximum flexibility for your design. In addition to those shown below, TRU can provide custom designs

and features per your specification. TRU also offers a broad range of panel mount receptacles with

high power/voltage capability and application specific launch geometries.

• Broad range of connectorand cable combinations

• kW power handling capabilities

• Quick Connect/Disconnectinterface technology

• Test and adapter solutions available

• Experience in high power designand safety innovations

High PowerRF Cable Assemblies

TRUflex™PWR Series

SC Straight Plug

SC Right AnglePlug

1-5/8 EIAStraight Plug

MEIA-1625Straight Plug

LC Right AnglePlug

7-16 Right AnglePlug

LC Straight Plug7-16 Straight Plug

2.45"

1.40"

3.75"

2.38"

4.35" 1.64"

3.50"

2.87"

1.62"

0.50"

2.75"

1.25"

3.10"

0.93"

3.06" 0.5"

1.63"

1.26"

1.17"

Dimensions shown are reference only.

Dimensions shown are reference only.

TRU Corporation Quick-Connect/Disconnect RF interface provides reliable mating with fast connect/disconnect

capability. These interfaces feature a positive locking mechanism employing a spring-loaded sleeve on the male

plug that is drawn back to let self-contained bearings “click” into grooves on the mating female receptacle, and

slide forward. A fully mated and safe condition is visually represented with full coverage of our TRU-Redline™

indicator. These designs provide exceptionally fast and reliable hand mating that will not vibrate loose.

Quick Connect/Disconnect Connector Configurations

TRU-SQS® spring-loaded sleeveis retracted and interfaces

engaged. Note TRU-Redline™indicator is still visible untilsleeve is released and a fullymated condition is present.

TRU-SQS® interfaces shownin a fully mated condition.

The right angle assembly canbe mated at any position alonga 360° arc offering optimalflexibility in the assembly

orientation.

TRU-SQS® right angle, cable plugand panel mount receptacle shown

in unmated condition.

TRU-SQS® Straight Plug TRU-QRM™ Straight Plug TRU-QDS® Straight Plug

TRU-SQS®

Right AnglePlug

TRU-QRM™Right AnglePlug

TRU-QDS®

Right AnglePlug

3.40" 2.70" 2.90"

1.70" 1.50" 1.13"

2.40"

2.00"

2.80"

1.90"

2.20"

1.50"

TRUflex PWR_trifold_031212_TRU.qxd:Layout 1 3/12/12 5:34 PM Page 1

Page 6: TRUflex Series - Richardson RFPD | Home | Richardson RFPD Cor… · TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 5/16/12 3:15 PM Page 2. Maximum Mating Voltage Interface Frequency

TRUflex™PWR Series

TRU Corporation,Peabody, MA 01960 USA

1 800 262-9878(1 800 COAX-TRU)978 532-0775052012-005

To request literature: [email protected]

trucorporation.com

Threaded and Flange Mount Connector Configurations

TRU offers a broad range of standard high power cable connector designs and configurations to provide

the maximum flexibility for your design. In addition to those shown below, TRU can provide custom designs

and features per your specification. TRU also offers a broad range of panel mount receptacles with

high power/voltage capability and application specific launch geometries.

SC Straight Plug

SC Right AnglePlug

1-5/8 EIAStraight Plug

MEIA-1625Straight Plug

LC Right AnglePlug

7-16 Right AnglePlug

LC Straight Plug7-16 Straight Plug

2.45"

1.40"

3.75"

2.38"

4.35" 1.64"

3.50"

2.87"

1.62"

0.50"

2.75"

1.25"

3.10"

0.93"

3.06" 0.5"

1.63"

1.26"

1.17"

Dimensions shown are reference only.

Corporate HeadquartersRichardson RFPD40W267 Keslinger RoadP.O. Box 307LaFox, IL 60147-0307 USAToll Free: 800-737-6937Phone: 630-208-2700Fax: 630-208-2662Internet: www.richardsonrfpd.comEmail: [email protected]

TRUflex PWR_trifold_051512_RFPD.qxd:Layout 1 5/16/12 3:39 PM Page 1