Trend IQ 3 Overview

69
IQ 3 Controller Overview IQ 3 Controller Overview Honeywell

Transcript of Trend IQ 3 Overview

Page 1: Trend IQ 3 Overview

IQ 3 Controller OverviewIQ 3 Controller Overview

Honeywell

Page 2: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S2 File Number

Honeywell

Introduction

Hardware

Ethernet Network

Configuration Setup

Portable Display Panel

Supervisor Software

Interface

Field devices

2 File Number

Course Objective

Page 3: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S3 File Number

Honeywell

INTRODUCTIONINTRODUCTION

Page 4: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S4 File Number

HoneywellEthernet –TCP/IP Networks

Introduction to TCP/IP

Ethernet TCP/IP is a suite of protocols Original intent of development was to have multiple routes which could be

used by computers communicating with each other. Developed by the “US Department of Defence” in 1973, mainly for the purpose

of interconnecting different brands of computers. TCP/IP is a non- proprietary product and is now the accepted communication

protocol on the Internet For more details on TCP/IP, visit the following website:

http://www.cisco.com

TCP = Transmission Control ProtocolTCP = Transmission Control ProtocolIP = Internet ProtocolIP = Internet Protocol

Page 5: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S5 File Number

HoneywellTREND Ethernet –TCP/IP Networks

Why TCP/IP network ?

Demand for simple and fast information access WWW becoming de-facto standard for B2B connectivity Total data connectivity (http, xml,.etc) Distribution of live information (mobile devices etc.) “Open” solution with lowest proprietary content (harness the IT and

Web world of solutions)

Increasing regulations Energy issues (Part L, Carbon taxes, cost volatility, etc.) requiring

control solutions

Changing building infrastructure On-line buildings linked directly to the Internet Flood-wired Ethernet networks becoming standard inside buildings

Market FactorMarket Factor

Page 6: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S6 File Number

HoneywellEthernet –TCP/IP Networks

Why TCP/IP network ?

IT / Web-based technology is widely implemented all over the world. Most widely used OPEN protocol network.

Even more popular than BACnet, LONwork, MODbus, etc. Make use of building or structure existing IT backbone setup.

Reduce cost and installation works. The smartest and best cost means of “liberating” field data for both operators

and other information systems. Move away from expensive but slow Lease Line.

Move away from a typical Building Management System network. No need of expensive software or specialised hardware for remote

access. Using commonly available web-browser for access such as INTERNET

EXPLORER

Employing Ethernet in Building SolutionEmploying Ethernet in Building Solution

Page 7: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S7 File Number

HoneywellEthernet –TCP/IP Networks

AdvantagesAdvantages

WWW

From anywhere, ... From anywhere, ... at anytimeat anytime

Web enabled: Makes it easy to access and control the building, in real-time, from a standard Web browser

Managers and operators can remotely; find out what’s going on in their buildings, take rapid action to help manage costs, correct comfort problems, etc.

Why TCP/IP network ?

Page 8: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S8 File Number

HoneywellEthernet –TCP/IP Networks

TREND Strategy..

Creating a WebCreating a Web--based Technology Systembased Technology System

Field level

Control level

Management level

IT levelIP

N

etw

orkin

g

D

irect w

eb

-servin

g

X

M

L etc..

Use IP networking as far down the system as is economically viable

Build native embedded web-serving capability as far down the system as is economically viable

And ultimately……Management and IT level communications in IT compatible formats

Page 9: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S9 File Number

HoneywellTREND IQ 3xx Controllers

IQ 3 XCITE : WHAT IS IT ?

INTRODUCTIONINTRODUCTION

A new platform controllerA new platform controller

Uses Ethernet and TCP/IP networking technologies, IT Uses Ethernet and TCP/IP networking technologies, IT network enable, accessible from anywhere.network enable, accessible from anywhere.

BuiltBuilt--in webin web--server, no proprietary software required to server, no proprietary software required to access controller or view user specified web pagesaccess controller or view user specified web pages

Modular Hardware Modular Hardware –– Extendibility and Flexibility, up to 96 Extendibility and Flexibility, up to 96 Input / Output pointsInput / Output points

DIN Rail MountedDIN Rail Mounted

Flexible number of strategy modules Flexible number of strategy modules –– Controllers optimised to applicationControllers optimised to application

Backward compatibility with predecessor controllers Backward compatibility with predecessor controllers –– IQ2 series of IQ2 series of controllercontroller

Page 10: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S10 File Number

Honeywell

Types of TREND IQ 3xx Controller :

TREND IQ 3xx Controllers

TRENDIQ 3Xact Controller

TRENDIQ 3Xcite Controller

Non-Expandable

(A) IQ 3Xact Series

(B) IQ 3Xcite Series

TRENDIQ 3Xcite Controller

Expandable

Controller Inputs & Outputs

IQ3xact/12 6 Analogue outputs & 6 Universal inputs

IQ3xcite/16 6 Analogue outputs & 10 Universal inputsonly

IQ3xcite/966 Analogue outputs & 10 Universal inputsPlus up to 80 extra points via I/O expansion modules

Page 11: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S11 File Number

HoneywellTREND IQ 3xx Series Controller

TREND IQ 3Xcite Expandable CONTROLLER

The following module board are available :The following module board are available :

NoteXcite 16DI module and Xcite 8DI module can accept both voltage free contact and 24 Vac supply.

Input / Output Modules :Input / Output Modules :

Modules is connected via a rigid connector or Belden cable 3084A for up to 30 metres Maximum up to 15 boards can be fitted, limited to an additional of 80 Input / Output

points

Page 12: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S12 File Number

HoneywellTREND Ethernet System

TRENDSupervisor Software

Management / Integration Level

TRENDIQ 3xx Controller

DDC / Field Controller Level

Field Devices LevelSensors Actuators

TRENDDevices

System Architecture :

3 Levels Hierarchy3 Levels Hierarchy Management Level Field Controller Level Field Devices Level

PeerPeer--toto--Peer, Distributed SystemPeer, Distributed System

Intelligence in Every ControllerIntelligence in Every Controller

Network or Standalone OperationNetwork or Standalone Operation

Compatible with Standard Protocols BACnet/IP LONworks Open Protocol Communication (OPC)

Page 13: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S13 File Number

HoneywellIntroduction to TREND IQ 3XCITE Controller

BuiltBuilt--in microprocessor, intelligence in every controller.in microprocessor, intelligence in every controller. MCF 5272 microprocessor, speed 66MHzMCF 5272 microprocessor, speed 66MHz Memory 16 Mbytes SDRAM & 8 Mbytes FlashMemory 16 Mbytes SDRAM & 8 Mbytes Flash BuiltBuilt--in Real in Real –– Time Clock Time Clock

No replaceable fuse required.No replaceable fuse required. Protected by a self resetting thermal solid state breakerProtected by a self resetting thermal solid state breaker AutoAuto--restart capabilitiesrestart capabilities

PeerPeer--toto--Peer ControllerPeer Controller Share Global Data among the Ethernet networkShare Global Data among the Ethernet network

Ethernet PlatformEthernet Platform

Network or standNetwork or stand--alone operationalone operation Ideal for individual or small equipment application for standIdeal for individual or small equipment application for stand--alone operationalone operation Able to support up to more than 13,400 controllers in a single network, sufficient for Able to support up to more than 13,400 controllers in a single network, sufficient for

large building services or application.large building services or application.

IQ 3XCITEIQ 3XCITE

IQ 3XCITEIQ 3XCITE

StandardStandard TRENDTREND IQ Controller FeaturesIQ Controller Features

IQIQ 33XCITEXCITE FEATURESFEATURES

Page 14: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S14 File Number

HoneywellIntroduction to TREND IQ 3XCITE Controller

StandardStandard TRENDTREND IQ Controller FeaturesIQ Controller Features

IQIQ 33XCITEXCITE FEATURESFEATURES

Optional Portable Display PanelOptional Portable Display Panel Smart Display Panel (SDU)Smart Display Panel (SDU) IQVIEW (Network Display Panel)IQVIEW (Network Display Panel)

Fully programmable to suit different applicationFully programmable to suit different application Proportional Integral Derivatives Control Proportional Integral Derivatives Control Boolean Algebraic & Logic ModuleBoolean Algebraic & Logic Module Function ModulesFunction Modules Optimisation Start/Stop ControlOptimisation Start/Stop Control Plant Rotation / Duty CyclingPlant Rotation / Duty Cycling Sequential ControlSequential Control Etc.Etc.

SMART SMART DISPLAY DISPLAY UNITUNIT

IQVIEWIQVIEW

Page 15: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S15 File Number

HoneywellIntroduction to TREND IQ 3XCITE Controller

Comply to Different Standards Comply to Different Standards UL Listed Standard (24 Vac)UL Listed Standard (24 Vac) EN Standards (100 EN Standards (100 –– 230Vac) 230Vac) BSI Standard : BS EN ISO 9001:2000BSI Standard : BS EN ISO 9001:2000 CE CertifiedCE Certified

Electromagnetic Compatibility Directive Electromagnetic Compatibility Directive (89/336/EEC)(89/336/EEC)

Low Voltage Directive (73123/EEC)Low Voltage Directive (73123/EEC)

StandardStandard TRENDTREND IQ Controller FeaturesIQ Controller Features

IQIQ 33XCITEXCITE FEATURESFEATURES

Page 16: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S16 File Number

HoneywellIntroduction to TREND IQ 3XCITE Controller

Additional FeaturesAdditional Features

IQIQ 33XCITEXCITE FEATURESFEATURES

Faster Network speedFaster Network speed Ethernet 10 Base T NetworkEthernet 10 Base T Network Network baud rate up to 10 Mbytes/secNetwork baud rate up to 10 Mbytes/sec

No memory battery backNo memory battery back--up required.up required. All strategy and data stored in nonAll strategy and data stored in non--volatile memoryvolatile memory

BuiltBuilt--in Web browser Capabilityin Web browser Capability

Use commonly available webUse commonly available web--browser for access browser for access

Page 17: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S17 File Number

HoneywellIntroduction to TREND IQ 3XCITE Controller

Individual Time Scheduling capabilities Allow more than 5 time zones per controller Unlimited number of switching per 24 hours duration period Incorporate override facilities for special events

Enhance security features More than 6 user can be set up Maximum up to 99 access level Support alphanumeric password up to 30 characters Automatic sign-off capabilities

Additional FeaturesAdditional Features

IQIQ 33XCITEXCITE FEATURESFEATURES

Page 18: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S18 File Number

HoneywellIntroduction to TREND IQ 3XCITE Controller

Enhance Alarm handling capabilities

Points in alarms will be highlighted in web pages Retransmit alarm to Supervisor software via IP address Retransmit alarm via SMTP to email server address

Additional LED Indicator

Power Indicator (Status & Fault) Watchdog Indicator (Software & RAM fault) Input / Output Bus Indicator (I/O Module Bus fault) Input / Output Terminal Indicator Network Transmission Indicator

Additional FeaturesAdditional Features

IQIQ 33XCITEXCITE FEATURESFEATURES

Page 19: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S19 File Number

Honeywell

HARDWAREHARDWARE

Page 20: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S20 File Number

Honeywell

Hardware Physical Layout

TREND IQ 3xx Controllers

Optional Battery CardIf an IQ 3Xcite Controller is set up to be a time master, an optional battery card is recommended to be installed. The battery shall help to maintain the Real Time Clock (RTC) for several years. However it need to be replaced every 5 years.

Page 21: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S21 File Number

Honeywell

Battery Back-up (Optional)

TREND IQ 3xx Controllers

IQ 3Xcite Battery CardIQ 3Xcite Battery Card

Battery CardBattery Card The optional battery card is used only to maintained the Real Time Clock. As memory is stored in Flash, hence no battery required.

Battery Card Battery Card –– Real Time ClockReal Time Clock

Page 22: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S22 File Number

Honeywell

Controller Power Supply

TREND IQ 3xx Controllers

Power Supply : 100 ~ 230 VacPower Supply : 100 ~ 230 Vac

Power Supply : 24 ~ 36 VdcPower Supply : 24 ~ 36 Vdc

Page 23: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S23 File Number

Honeywell

Controller Interface

TREND IQ 3xx Controllers

Page 24: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S24 File Number

Honeywell

Controller Data Storage

TREND IQ 3xx Controllers

Page 25: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S25 File Number

Honeywell

Hardware Physical Layout

TREND IQ 3xx Controllers

Expandable ModuleExpandable Module

BUS I/O ConnectionBUS I/O Connection

Power SupplyPower Supply

Module Address Module Address SwitchSwitch

Page 26: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S26 File Number

Honeywell

Hardware Physical Layout

TREND IQ 3xx Controllers

Expandable Module RangeExpandable Module Range

8 Channel Module8 Channel Module

Page 27: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S27 File Number

Honeywell

Hardware Physical Layout

TREND IQ 3xx Controllers

Expandable Module RangeExpandable Module Range

4 Channel Module4 Channel Module

Page 28: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S28 File Number

Honeywell

Hardware Physical Layout

TREND IQ 3xx Controllers

Expandable Module RangeExpandable Module Range

16 Channel Module16 Channel Module

I/O ModulesI/O Modules

Page 29: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S29 File Number

HoneywellTREND IQ 3xx Series Controller

Rigid ConnectorRigid Connector

Expandable ModuleExpandable Module

EndEnd--ofof--Line TerminatorLine Terminator

Adjacent Rigid InterAdjacent Rigid Inter--connectorconnector

Page 30: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S30 File Number

HoneywellTREND IQ 3xx Series Controller

Cable ConnectorCable Connector

Expandable ModuleExpandable Module

Wire Connector (terminator)Wire Connector (terminator)

Page 31: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S31 File Number

HoneywellTREND IQ 3xx Controllers

Auxiliary Power Supply Auxiliary Power Supply –– 24Vdc24Vdc

Page 32: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S32 File Number

HoneywellTREND IQ 3xx Controllers

Power Supply (I/O Modules)Power Supply (I/O Modules)

Page 33: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S33 File Number

HoneywellTREND IQ 3xx Controllers

Power Supply (I/O Modules)Power Supply (I/O Modules)

24 Vdc Power Supply (max 1.3 A)24 Vdc Power Supply (max 1.3 A)

24 Vdc Power Supply (max 2.5 A)24 Vdc Power Supply (max 2.5 A)

24 Vdc Power Supply (max 5 A)24 Vdc Power Supply (max 5 A)

Page 34: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S34 File Number

Honeywell

ETHERNET NETWORKSETHERNET NETWORKS

Page 35: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S35 File Number

HoneywellEthernet Networks

TREND Ethernet Networks SUPERVISORSUPERVISOR

IQ 3XCITEIQ 3XCITE

TREND ETHERNETTREND ETHERNET

IQ 3 series controllerIQ 3 series controller

Uses Ethernet and TCP/IP networking technologies, IT Uses Ethernet and TCP/IP networking technologies, IT network enable, accessible from anywhere.network enable, accessible from anywhere.

WAN

Page 36: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S36 File Number

HoneywellEthernet Networks

Physical MediumNetwork CableNetwork Cable

10 Base T10 Base T Use a Physical “STAR” Topology, but uses a Logical “BUS” Topology for communicationUse a Physical “STAR” Topology, but uses a Logical “BUS” Topology for communication Device attach to HUB using a CAT3 or higher twisted pair cableDevice attach to HUB using a CAT3 or higher twisted pair cable HUBs & devices have LINK LED which indicates the segment is healthy HUBs & devices have LINK LED which indicates the segment is healthy Expand the network by daisy chaining HUB,Expand the network by daisy chaining HUB, Other similar networks in this styleOther similar networks in this style

100 Base T 100 Base T –– CAT5 (100Mbytes/s)CAT5 (100Mbytes/s) 1000 Base T 1000 Base T –– CAT6 (1Gbytes/s)CAT6 (1Gbytes/s)

Page 37: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S37 File Number

HoneywellEthernet Networks

Physical MediumNetwork CableNetwork Cable

Types of cable (Ethernet)Types of cable (Ethernet)

Page 38: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S38 File Number

HoneywellEthernet Networks

Physical MediumTREND Ethernet Devices (Industrial Rate)TREND Ethernet Devices (Industrial Rate)

Industrial rate network equipment is designed to operate in harsh industrial environmental.Industrial rate network equipment is designed to operate in harsh industrial environmental. DIN rail mounting and suitable for use in controller enclosureDIN rail mounting and suitable for use in controller enclosure

TREND EDA-2055 port switch

TREND EDS-3055 port switch

4 x 10/100 Base T & 1 x 100 Base T

TREND IMC-101Media Convertor

10/100 Base T to 100 Base Fx

EDAEDA--205 205 –– 5 port Ethernet Switch5 port Ethernet Switch

EDSEDS--305 305 –– 5 port Ethernet Switch5 port Ethernet Switch

IMCIMC--101 101 –– Media ConvertorMedia Convertor

Page 39: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S39 File Number

HoneywellConfiguration

Web Pages ConfigurationIntroduction Introduction

IQ 3 controllers incorporate a web server which can deliver userIQ 3 controllers incorporate a web server which can deliver user--specific pages to a specific pages to a computer running standard internet browser software.computer running standard internet browser software.

IQ 3XCITEIQ 3XCITE

Page 40: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S40 File Number

HoneywellConfiguration

Web Pages ConfigurationWelcome Page Welcome Page

IQ 3 controllers incorporate a web server which can deliver userIQ 3 controllers incorporate a web server which can deliver user--specific pages to a specific pages to a computer running standard internet browser software.computer running standard internet browser software.

Page 41: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S41 File Number

HoneywellConfiguration

Web Pages ConfigurationModule Page Module Page

Module page options allows the user to see the controller strategy.Module page options allows the user to see the controller strategy. Values can be changed with the keyboard and sent with either”Enter” or one of the Values can be changed with the keyboard and sent with either”Enter” or one of the

adjustment icons.adjustment icons.

Page 42: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S42 File Number

HoneywellConfiguration

Web Pages ConfigurationPlant GraphIQsPlant GraphIQs

Using Display & Directory Modules we can create Plant Graphics Using Display & Directory Modules we can create Plant Graphics

Page 43: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S43 File Number

HoneywellConfiguration

Web Pages ConfigurationCreate GraphIQsCreate GraphIQs

Page 44: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S44 File Number

HoneywellConfiguration

Security ConfigurationDefault Default –– System GuestSystem Guest

IQ 3 controllers incorporate a security features to prevent unathuorised access to IQ 3 controllers incorporate a security features to prevent unathuorised access to the parameter of the controller.the parameter of the controller.

However, as default, no user is set up at the controller. However, as default, no user is set up at the controller. Although no user is set up, one user still exist; System Guest with L100 (level 100) Although no user is set up, one user still exist; System Guest with L100 (level 100)

access).access). If you do not Log into the IQ 3 controller, you are log in as a System Guest which If you do not Log into the IQ 3 controller, you are log in as a System Guest which

allow you full access for an unprotected controllerallow you full access for an unprotected controller

Page 45: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S45 File Number

HoneywellConfiguration

Security ConfigurationDefault Default –– System GuestSystem Guest

As soon as you configure a user, the System Guess access level is changed to LAs soon as you configure a user, the System Guess access level is changed to L--1 1 (level (level --1).1).

Hence basic read only access is givenHence basic read only access is given However, user 1 should always be configured at level 99 first and removed last.However, user 1 should always be configured at level 99 first and removed last.

System Guest with readSystem Guest with read--only accessonly access

Page 46: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S46 File Number

HoneywellConfiguration

Security ConfigurationLevel of AccessLevel of Access

Once Users are configured, the module view window will only show appropriate Once Users are configured, the module view window will only show appropriate modules depending on level accessmodules depending on level access

Page 47: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S47 File Number

Honeywell

PORTABLE DISPLAY PANELPORTABLE DISPLAY PANEL

Page 48: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S48 File Number

HoneywellPortable Display

Display PanelIntroductionIntroduction

TREND have provided portable display panel for the new IQ 3 network systemTREND have provided portable display panel for the new IQ 3 network system

TREND IQ VIEW Display TREND Smart Display Unit (SDU)

Page 49: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S49 File Number

Honeywell

TREND Network Display Panel

A touch screen network display panel for interface to the TREND System

IQ VIEW Portable Display

Features

Provide a user interface to the TREND IQ system Self-configuration Display graphs View & adjustment of system values View alarms Trend Loop or Ethernet Connection Password user protection

Portable Display

TREND IQ VIEW Display

Page 50: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S50 File Number

HoneywellPortable Display

Display PanelIQ View IQ View –– Overview Overview

Page 51: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S51 File Number

HoneywellPortable Display

Display PanelIQ View IQ View –– PhysicalPhysical

Page 52: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S52 File Number

HoneywellPortable Display

Display PanelIQ View IQ View –– ConnectionConnection

Via the BuiltVia the Built--in Vcncin Vcnc

Page 53: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S53 File Number

HoneywellPortable Display

Display PanelIQ View IQ View –– ConnectionConnection

Via thirdVia third--Party VcncParty Vcnc

Page 54: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S54 File Number

Honeywell

TREND Portable Display Panel

A small display panel for interface to the TREND System

Smart Display Unit (SDU)

Portable Display

Features

Electroluminescent 4 x 20 character display

Illuminated button for selection or adjustment

Allows viewing and adjustment of plant parameters.

Display the alarm log

Access IQ via supervisor port only.

Variant of smart display unit

IQ Current loop controllers

IQ Xcite Ethernet controller

IQL LON Controllers.

TREND Smart Display Unit (SDU)

Page 55: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S55 File Number

Honeywell

SUPERVISOR SOFTWARESUPERVISOR SOFTWARE

Page 56: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S56 File Number

Honeywell

INTRODUCTION

SUPERVISOR SOFTWARESUPERVISOR SOFTWARE : WHAT IS IT ?

A real time, user interface independent of the A real time, user interface independent of the TRENDTREND System to allow System to allow monitoring and parameter adjustment to the system controllers.monitoring and parameter adjustment to the system controllers.

Supervisor Software

Main Features :

Device Viewer Device Viewer Graph DisplayGraph Display Password Access Password Access Scheduling CapabilitiesScheduling Capabilities Alarm ManagementAlarm Management

Types of TREND Supervisor Software:

Workstation Supervisor - 963 Supervisor Software Pocket PC Supervisor - 916 Mobile Display Software (MDS)

TREND963 Supervisor

Software

TREND916 MDS Software

Page 57: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S57 File Number

HoneywellSupervisor Software

Time Schedules Set-point AdjustmentRecord Trend Logs

Alarm Database Password Protection Email Retransmission

TREND 963 Supervisor Software

Client -Server

Schematics Page

Features :

A graphicalgraphical, real-time interface software for monitor / control for the TREND building system – Workstation Supervisor

Page 58: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S58 File Number

Honeywell

Available in different version:

963 Lite963 LiteMost basic package which provide all the fundamental features required of a supervisory package

963 Server963 ServerSimilar facilities with 963 Lite in addition of enabling the 963 to act as a web server allowing access through a web browser software such as Internet Explorer

963 Secure963 SecureSimilar facilities with 963 Lite plus an additional security features to comply to FDA Regulation 21 CPR Part 11 for pharmaceutical application

963 SNMP963 SNMPSimilar facilities with 963 Lite plus the capabilities of retransmitting alarm in Simple Network Management Protocol (SNMP) format

963 SMS Direct963 SMS DirectSimilar facilities with 963 Lite plus the capabilities of retransmitting alarm in Short Message Services (SMS) text messaging. GSM modem included

TREND Workstation Supervisor

Page 59: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S59 File Number

HoneywellSupervisor Software

TREND 916MDS Software

A portableportable, real-time interface software for monitor / control for the TREND building system – Pocket PC Supervisor

Navigator Alarm LogsMonitoring Data Trend Logs

Features Small hand held device – true portability Instant operation, fast connection, Any Where Simple interface, easy to train, easy to use Ethernet (wireless), GSM, Bluetooth, Serial connection Trend parameters can be viewed and adjusted

Page 60: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S60 File Number

Honeywell

INTERFACEINTERFACE

Page 61: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S61 File Number

Honeywell

TREND Relay Module Single Relay Module (SRMV) :

Enables a controller analogue voltage output signal to drive a single changeover relay (Digital Output)

Maximum resistive load 8 Amps TREND

Single Relay Module Voltage

Interface Device

2 Single Relay Module AC (2 SRM) :

Enables two controller analogue voltage output signal to drive two single changeover relay independently (Digital Output)

Maximum resistive load 5 Amps with manual override link TREND

Single Relay Module AC

Page 62: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S62 File Number

Honeywell

Two Voltage (V) to two Current (I) Converter Driver Module (2VID)

Converts two channel controller analogue voltage output signal (0 to 10Vdc) to two current output signal (0 mA to 20 mA)

Manual override links for aid of commissioning. TREND

2VID Module

Interface Device

TREND Signal Converter Module

Voltage (V) to Pneumatic Converter Driver Module (PN/VPC)

Converts a controller analogue voltage output signal (0 to 10Vdc) to a proportional pneumatic signal (0.2 bar to 1bar)

Requires an external 24 Vac power supply. TRENDPN/VPC Converter

Module

Page 63: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S63 File Number

Honeywell

FIELD DEVICESFIELD DEVICES

Page 64: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S64 File Number

Honeywell

TREND provides a wide range of field devices to suit the need of many different applications.

Field Devices

Range of Field Devices

Field Sensors Temperature, Humidity, Pressure, Air Quality, Carbon Dioxide, Velocity

Field Switches Differential Pressure

Electricity Meters Current Transformer, Multi-parameter meter

Detectors Occupancy

Electronic Actuators Valve, Damper

Valves Threaded, Flanged

Variable Speed Drive

Page 65: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S65 File Number

Honeywell

Plant Temperature sensor Receiver

coverage of up to 32 sensors with a single receiver covering up to 17,000m2

No cable, no screwdriver, no hassle Simple set-up software Battery life in excess of 5 years

TREND Wireless Temperature Sensors

TRENDWireless Sensor

Field Devices

TRENDTW/S Sensor

TRENDTW/P Sensor

TRENDXW/R/IQ Transmitter

TRENDIQ 3Xcite Controller

Page 66: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S66 File Number

Honeywell

Space temperature sensor c/w 3 digit display Indication & Adjustment of Set-point Indication of fan speed and occupancy

Connect to the controller via supervisor port (T-Bus) Can display reading in either Celsius or Fahrenheit Available in two variants

IQ version : IQ 2xx & IQ 3xx controllers IQL version : IQL controllers

TREND LCD Temperature Sensors

TRENDRoom Display Unit

Field Devices

Page 67: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S67 File Number

HoneywellSummary

TREND Network Summary

IQ VIEW

TMNG

TMNG

GSM

LAN

ENC2

IQ VIEW

EM/MPO

SUPERVISOR

MOBILE SOFTWARE

ETHERNET

IQ 3XACT

CNC2

LAN

IQ 242

PNC

LINC

Page 68: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S68 File Number

HoneywellTREND System

Applications

Typical Building Application

Page 69: Trend IQ 3 Overview

N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S69 File Number

Honeywell

THE ENDTHE END

Thank you for your attentionThank you for your attention