Trap Skeet Overlay Counter Setup · Wireless Trap Release Long RANGE Wireless Trap Release...

2
Wall Transformer Trap for Trap Field Low House for Skeet Field High House for Skeet Field Trap Release Wires Red +12 Volts DC Black -12 Volts DC White White Green Black Trap Release Wires White Black Trap Release Wires TRAP SKEET SKEET HIGH SKEET LOW TRAP LongRANGE Wireless Trap Release LongRANGE Wireless Trap Release Trap/Skeet Overlay Counter Setup Note: Included is a 110/240 Vac to 12 Vdc Transformer. Wire with White Dashes from Transformer is +12V 135 foot pull cord plugs into the bottom of the counter using a 5-pin XLR plug - - - - - - - - - - - - - - - - - - - - Long Range offers the option to place a counter unit on your Trap/Skeet Overlay field. A single counter is attached to a junction box which will connect to 3 trap machines: your high house and low house of your Skeet Field, and a single trap for your Trap Field. This allows you to switch between a skeet field and a trap field with a simple turn of a key. Follow the diagram below to properly setup your counter unit.

Transcript of Trap Skeet Overlay Counter Setup · Wireless Trap Release Long RANGE Wireless Trap Release...

Wall Transformer

Trap for Trap Field

Low House for Skeet Field

High House for Skeet Field

Trap Release Wires

Red +12 Volts DC

Black -12 Volts DC

White

White

Green

Black

Trap Release Wires

White

Black

Trap Release Wires

TRAP SKEET

SKEET HIGH SKEET LOW

TRA

P

LongRANGEWireless Trap Release

LongRANGEWireless Trap Release

Trap/Skeet Overlay Counter Setup

Note:Included is a 110/240 Vac to

12 Vdc Transformer. Wire with White Dashes from

Transformer is +12V

135 foot pull cord plugs into the bottom of the

counter using a 5-pin XLR plug

- - - - - - - - - - - - - - - - - - - -

Long Range offers the option to place a counter unit on your Trap/Skeet Overlay field. A single counter is attached to a junction box which will connect to 3 trap machines: your high house and low house of your Skeet Field, and a single trap for your Trap Field. This allows you to switch between a skeet field and a trap field with a simple turn of a key. Follow the diagram below to properly setup your counter unit.

Wall Transformer

Trap Release Wires

XLR Adapter Plugs into Counter UnitRed +12 Volts DC

Black -12 Volts DC

WhiteGreen

The trap’s release wires would normally connect to the Canterbury Control Box

CanterburyPower Supply

CanterburyRelease Wires

The Canterbury’s release wires would normally connect to the Trap

Machine

Black

Green

Red

WhiteUsed for DOUBLES (if needed)

Used for LOW HOUSE (if needed)

LongRANGEWireless Trap Release

Canterbury Voice Release Adapter

Note:Included is a 110/240 Vac to 12 Vdc

Transformer. Wire with White Dashes from Transformer is +12V

- - - - - - - - - - - - - - - - - - - -

With the use of a 4-core adapter, Long Range’s line of counter units can be integrated into your existing Canterbury system. As you can see below, the Canterbury Control Box’s release wires are connected to the counter using the adapter. The hard wired 4-core cable will provide power to the counter using the provided transformer as well as release the trap using the green and white wires.