TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

34
TRANSPORTABLE STAND ALONE TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR MULTIGAS DETECTOR BM 25 BM 25

Transcript of TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Page 1: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

TRANSPORTABLE STAND ALONE TRANSPORTABLE STAND ALONE MULTIGAS DETECTORMULTIGAS DETECTOR

BM 25BM 25

Page 2: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

STAND ALONE DETECTOR:

BM25BM25• Rugged

• Has been specially designed for operation in harsh and corrosive environments

• High visibility and audible alarm• Fitted with a large flashing red LED

module • and 2 « loud hooters » : 103db/1m.

Page 3: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Safety in the field

• Designed for team protection:rescue teams…

• Area surveillance for mobile or short term works

• Used where fixed detection systems are inapropriate or not present

Page 4: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25 = rugged MX 2100 version

• Keep the MX2100 characteristics and other new functions :

• a new king of cells «serie 7/3 » • programmable relay outputs «gas and

fault alarms  »• 2 programmable 1/0 inputs• charger input• Trickle charge in EX areas• Safety perimeter

• RS485 or radio communication outputs ; (new developments).

Page 5: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25: description

Red flashing beacon(protected)

Loud hooters

protected buttons

2 connectors(outputs) on each

side of casing

LCD display

Carrying handle

sensors

Sizes:467x195x180mm (H P L)

Weight : 6.8 kgsIP 66

Page 6: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25: description

Page 7: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 :external connectorsright side

Left side

Relay outputs (default and gas) and 2 logic inputs (remote acknowledment and remote alarm)I/O RS485 (new development)

Charger (230ACVor 12 to 30 DCV)

Trickle charge input

Page 8: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Example of remote alarmExample of remote alarm 0 % CH4

GASGAS

ALARME1 20.9 % O2

15 : 05 : 290 ppm CO 0 ppm H2S

20.9 % O2

AL. TRANSFERT 0 ppm CO 0ppm H2S Message of remote

alarm

Page 9: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

GAS AL

STRAIGHT FORWARD

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarm transfert : activated

AL. TRANSF

Junction box

Page 10: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

STRAIGHT FORWARD

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarm transfert : activated

GAS ALAL. TRANSF

x

Page 11: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

LOOP / SAFETY PERIMETER

AL. TRANSF

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarm transfert : activated

GAS AL

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

Page 12: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

LOOP / SAFETY PERIMETER

AL. TRANSF

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarrm transfert : activated

GAS AL

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

ACKNOLEDGEMENT

Page 13: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

LOOP / SAFETY PERIMETER

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarrm transfert : activated

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

Page 14: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

LOOP / SAFETY PERIMETER

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarrm transfert : activated

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF

AL. TRANSF To acknowledge :

1/ open the loop

2/ acknowledge each BM25

ACKNOWL.

ACKNOWL.

ACKNOWL.

ACKNOWL.

ACKNOWL.

ACKNOWL.

ACKNOWL.

Page 15: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

GAS AL

STAR INTERCONNECTION

Max. BM25 connected : Unlimited

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarrm transfert : activated

GAS AL

AL. TRANSFERT

Page 16: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

AL. TRANSFERT

TREE INTERCONNECTION

Max. BM25 connected : 3 + 1

Cable : 01 IP 09 EG SF

Cable : 02 IP 05 EI SF

Input 1 : activated

Output 1 : activated on all alarms

Alarrm transfert : activated

GAS AL

AL. TRANSFERTAL. TRANSFERT

Page 17: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Example of remote alarmExample of remote alarm ( logic inputs)

0 % CH4 20.9 % O2

AL. TRANSFERT

0 ppm CO0 ppm H2S

« manual call point »FUNCTION

Page 18: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 : batteries

• Pack of NiMH batteries (7V2/9AH), rechargeable without opening

• Autonomy = according to the configuration :

• Up to 170h operations non-stop

• Or for example 90 hours with explo/O2 and 2 toxic cells.

• Recharged in less than :4h30mn.

Page 19: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 : remote power supply

• It’s possible to trickle the BM25 in a classified zone linked with «a remote intrinsic safety power  » (with flammable and toxic cells only)

• For these reason,in this case and without alarm, the BM25 will work practically indefinitely !!

• But with alarm triggering,batteries will be discharged a bit.

Page 20: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Remote power supply in a Remote power supply in a classified zone classified zone

Intrinsically safe remote

power supply

ZONE 0

Zone 0 Safety zone

BM 25

Page 21: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25: smart blocks• 1 and 2= mini toxic or O2

smart block of cell• 3= médium toxic or O2 • 4= EXPLO smart block

of cell• 5= médium or series 3/7

(new developments).

4 1

2

35

Note: without a block somewhere, take in place adummy cell to keep the index of protection (IP66).

Page 22: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25: smart blocks• All the cells are:

• « plug in » easy connexion

• smart because fitted with a memory of characteristics (type of detected gas, unit, scale, sérial number, usure rate etc…

• Pre-calibrated

• Interchangeable.

Page 23: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25: smart blocks• Channel 5 can be fitted

with either a medium cell or a big model (series 3)

• Note: BM 25 is fitted with 5 channels but can make a gestion of 4 only!

• For this reason if you use the channel N° 5, the 1 st will be automatically inhibited and the cell deactived !

4 1

2

35

Page 24: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25: explosible smart-blocks

• This channel is obligatory connected with a flammable cell for detection of major explo.gas and 2 types of cell can be used :

• catalytic or• catalytic/catharometric .

Page 25: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25BM25: explosible smart-blocks

• « universal »: catalytic cell

• Scale of measurement = 0 to 100% LEL

• « Non ambiguity measurement message » if the signal is tooà high > 100% LEL

• Choice of detected explo. gas (preprogrammed list)

• choice of a special type « all the gas »: the new cell, recently developped by Oldham, will indicate a correct concentration of the explo. gas detected whatever the type and in spite of a unic calibration with CH4 (different curves of explo. gases are very closed).

• catalytic/catharometric cell:

• Scale of measurement = 0 to 100%LEL / 0 to 100% gas/ volume with an automatic commutation of scale

• Note: to use this « LEL/volume » version, it’s obligatory to equip the BM25 with an oxygen cell !

Cellule explo classiqueLEL

Reading

100%

50%

0%

CH4

Butane

H2NH3

GPL

LEL

10% Max.

Page 26: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25:avaible smart blocksBM25:avaible smart blocks

Page 27: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 OPTIONS

Page 28: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 : pumping system

• Avaible in option: the BM25 can be fitted with an included electric pump

• Associated with a remote sampling system (cap of cells and different king of probes)

• automatic working pump if a cap fixed….

gaz

Page 29: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

Optical IR linking Optical IR linking forfor COM 2100 COM 2100

• An IR port located on the right side of BM25 allows the linking to a PC

• serial RS232 or USB cables are avaible 

• COM 2100 software will recognize automatically a linking to a BM25 or to MX2100

• common software MX2100/BM25.

Page 30: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

modules of communicationmodules of communication

• Each following modules wil be installed on demand in the instrument, outputs will be avaible on right side:

• RS485• 4 to 20 mA• CATEX ( TOTAL)• Others on demand ….

Page 31: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM25 in the field = example of option (legs)

Semi-portable or permanently installed

Page 32: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 : CERTIFICATIONS : CERTIFICATIONS

• BM25 (fitted with cells) it’s approved intrinsically safety category 1 category 1 (very high level of safety)

• So usable in zones 0 ! usable in zones 0 !• ATEX II 1 GD EEx ia IIC T4 (except with CO2)

• ATEX I M1 (mines)• Other certifications running: INDIA,

RUSSIA, CHINA …

Page 33: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 = very high level of = very high level of safety !safety !

• The BM25 BM25 is a is a Categorie 1 instrument Categorie 1 instrument and can be used in zones zones 00 and directly in the tank

• Using without sampling systems

• And with remote informations of alarms…

Page 34: TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.

BM 25BM 25 : examples of : examples of applicationsapplications

• industrial and maintenance sites

• for manipulations of dangerous substances

• chemical fire brigades

• in tunnels, in confined spaces , in sewers …

• wastewater stations

• Aircraft maintenance workshops

• Coal mines

• In storage tanks, underground storage tanks…