Transport SX GT62F-B8026 Quick Installation Guide · 2020. 4. 13. · Remove the Air Duct (1)...

1
Transport SX GT62F-B8026 Quick Installation Guide Document # D2408 - 100/ Revision 1.0 5 Caution 4 I/O Ports 1 a a b b c c d d e e CPU Socket (P0) CPU Socket (P0) P0_D0_Umc0_Ch_D1 P0_D0_Umc0_Ch_D1 P0_D0_Umc0_Ch_D0 P0_D0_Umc0_Ch_D0 P0_D0_Umc1_Ch_C1 P0_D0_Umc1_Ch_C1 P0_D0_Umc1_Ch_C0 P0_D0_Umc1_Ch_C0 P0_D1_Umc1_Ch_B1 P0_D1_Umc1_Ch_B1 P0_D1_Umc1_Ch_B0 P0_D1_Umc1_Ch_B0 P0_D1_Umc0_Ch_A1 P0_D1_Umc0_Ch_A1 P0_D1_Umc0_Ch_A0 P0_D1_Umc0_Ch_A0 P0_D3_Umc0_Ch_E0 P0_D3_Umc0_Ch_E0 P0_D3_Umc0_Ch_E1 P0_D3_Umc0_Ch_E1 P0_D3_Umc1_Ch_F0 P0_D3_Umc1_Ch_F0 P0_D3_Umc1_Ch_F1 P0_D3_Umc1_Ch_F1 P0_D2_Umc1_Ch_G0 P0_D2_Umc1_Ch_G0 P0_D2_Umc1_Ch_G1 P0_D2_Umc1_Ch_G1 P0_D2_Umc0_Ch_H0 P0_D2_Umc0_Ch_H0 P0_D2_Umc0_Ch_H1 P0_D2_Umc0_Ch_H1 Battery Socket (CR1) Battery Socket (CR1) f f g g h h A B C D 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 i i ii ii iii iii iv iv v v vi vi vii vii viii viii ix ix x x xi xi xii xii 31 32 33 34 35 36 37 38 39 40 41 Read Me First 1. The Barebone User’s Manual is available for download from our Web site at http://www.tyan.com. Make sure to read all precautions and instructions before you start installing the server system. 2. Refer all servicing to qualified personnel to avoid the risk of damage to the server system. 3. Exercise normal ESD (Electrostatic Discharge) procedures during system integration. TYAN/MiTAC recommends wearing gloves and an anti-static wrist strap to avoid possible damage to the equipment. 4. Current processor socket design places the pins on the motherboard instead of the processor itself. Exercise caution when installing the processors as the manufacturer’s warranty does not cover damage inflicted upon the motherboard, including damage to the CPU sockets. Tools Required 1 General Information 3 System Installation Box Content Accessories 2 Motherboard Placement Motherboard Placement Rear View Front View Install the Add-On Card (Optional) 1 3 Preparing the Chassis Read normal ESD (Electrostatic Discharge) procedures. Place your TYAN ® Server Chassis on a flat anti-static surface to perform the following integration procedures. Read ESD procedures before reaching inside to install components. Open the Chassis 2 Minimum Hardware Requirements To avoid integration difficulties and possible board damage, your system must meet the following minimum requirements: • Processor: AMD EPYC SoC Series CPU with TDP up to 180W • Memory Type: (16) DDR4 DIMM slots, (8) channels with (2) DIMM slots per channel • Hard Disk Drives: (10) hot-swap 2.5” SATA 6G HDD/ SSD or NVMe • Rack Mount Kit (Industry 19" rack-mountable) NOTE: For an up to date list of compatible hardware, please visit the system’s support page on www.tyan.com Required Hardware Components Install the Hard Disks (2.5”) Remove the Air Duct (1) M1286G62F-BP12E-10-B8026 HDD BP (for B8026G62FE10HR only) (1) M1274G62B-BP12-10-B8026 HDD BP (for B8026G62FV10HR-LE only) Loosen the thumb screw on the back side. Slide to release the top cover and then remove. Remove the screw securing the top cover. 1 Lift to remove the air duct. 5 Reinsert the HDD tray into the chassis. 3 Remove the screws securing the HDD tray bracket to the HDD tray. Then remove the HDD tray bracket. 6 Push the locking lever firmly to secure the tray. Repeat the same procedures to install other HDD trays. 4 Place a hard drive into the drive tray. Affix the four screws to secure the HDD. 2 Slide the HDD tray out. 1 Pull the locking lever open. 1 2 3 (1+1) Hot-Swappable Power Supply Modules (PSU1 / PSU2) 1 I/O Ports 2 Optional OCP card 4 Expansion Slots 3 CPU Cover for DOA/RMA Locate the External I/O Port Phillips Screwdriver Flat-head Screwdriver Anti-Static Wrist Strap T20 Torx Screwdriver 8 B8026G62FE10HR SKU 1 B8026G62FV10HR-LE SKU 2 2 Lift to remove the riser bracket. 1 4 3 5 Carefully flip the riser bracket. Then align and install the riser bracket to its slot on the chassis. 6 Secure the riser bracket to the chassis with two screws. Insert the add-on card to the riser bracket. Make sure the add-on card is latched into the riser bracket. Then secure the add-on card to the riser bracket with a screw. Unscrew the riser bracket. Flip the riser bracket and place on the surface. Then unscrew and remove the PCI dummy bracket (1) M1716G75-FPB (1) Power Distribution Board (1) S8026GM2NR-LE Pre-installed in B8026G62FV10HR-LE sku (1+1) ERP1U 650W/ RPSU, 80+ Platinum DPS-650AB-14 D (1) S8026GM2NRE pre-installed in B8026G62FE10HR sku CONNECTORS 1 RJ45+USB3.0x2 (LAN3) 2 SGPIO Header (SGPIO0) 3 VGA + COM PORT (VGA_COM1) 4 SGPIO Header (SGPIO1) 5 Broadcom BCM5720 LAN Connector (LAN2) 6 BMC SPI Socket (BMC_SOCKET1) 7 Broadcom BCM5720 LAN Connector (LAN1) 8 BIOS SPI Socket (BIOS_SOCKET1) 9 REAR ID LED BTN (IDLED_BTN1) 10 REAR FAN_2 (SYS_FAN_5) 11 REAR FAN_1 (SYS_FAN_4) 12 COM2 Header (COM2) 13 NGFF 22x110mm Connector (NGFF2) 14 Vertical Type A USB Connector (TYPEA_USB1) 15 NGFF 22x110mm Connector (NGFF1) 16 SATADOM Connector(SATA 3.0 signals) 7Pin+2Power (SATADOM2) 17 SATADOM Connector(SATA 3.0 signals) 7Pin+2Power (SATADOM1) 18 FPB USB2.0/USB3.0 *2 Header (USB3_FPIO1) 19 PCIE 80P OCULINK CONN (OCUL6) 20 PCIE 80P OCULINK CONN (OCUL8) 21 PCIE 80P OCULINK CONN (OCUL7) 22 PCIE 80P OCULINK CONN (OCUL3) 23 PCIE 80P OCULINK CONN (OCUL4) 24 PCIE 80P OCULINK CONN (OCUL5) 25 FRONT FAN_3 (SYS_FAN_3) 26 PCIE/SATA 80P OCULINK CONN (OCUL2) 27 PCIE/SATA 80P OCULINK CONN (OCUL1) SLOTS A PCIE3.0 SLOT x24 (PESLOT1) B PCIE3.0 SLOT x24 (PESLOT2) C OCP 2.0 A Slot (OCP1_A) D OCP 2.0 B Slot (OCP1_B) 28 FRONT FAN_2 (SYS_FAN_2) 29 FRONT FAN_1 (SYS_FAN_1) 30 CPU_FAN (CPU_FAN) 31 System Fan Connector (FAN_HD1) 32 Front Panel Header (FPIO_2) 33 PSMI Header (PSMI_HD1) 34 IPMB Header (IPMB1) 35 8-pin Power Connector (PW3) 36 8-pin Power Connector (PW2) 37 ATX Power Connector (24p) (PW1) 38 Reset Button (COLD_RST_BTN1) 39 Power Button (PWR_BTN1) 40 NMI Button (NMI_BTN) 41 TYAN Module Header (DBG_HD1) JUMPERS a CMOS Clear jumper (J194) b BMC COM PORT2(RX) Jumper (J190) c BMC COM PORT2(TX) Jumper (J191) d PC BEEP Jumper (J120) e OCP CONN MUX & PRSENT select Jumper (3PHD11) f System RESET Jumper (J192) g J1 NVMe or SATA select Jumper (J9_13) h J2 NVMe or SATA select Jumper (J9_24) LEDs i FPGA_CRC_ERROR LED (LED1) ii FPGA_NSTATUS LED (LED2) iii FPGA_CONF_DONE LED (LED3) iv P0_PROCHOT_LED (LED4) v PWR_GOOD_LED (LED5) vi RESET_LED (LED7) vii NGFF1_LED (LED_M1) viii NGFF2_LED (LED_M2) ix HDD_ACT_LED (HDD_LED3) x On board BMC IPMI ALERT LED (IPMI_LED2) xi PSU_ALERT_N LED (PSMI_LED1) xii BMC Heartbeat LED (BMC_HBLED) Install the Memory 1 Unlock the clips. 2 Insert the memory module. 3 Lock the clips. Install the Processor Install the CPU Heatsink 3 Remove the external cap from the rail frame. 5 Using your thumb and forefinger, remove the PnP cap by lifting it up vertically. 1 Use a T20 Torx screwdriver to loosen the screws securing the force frame in a sequential order (321). NOTE: The force frame will automatically eject after the captive screws are being released. 6 Carefully close the rail frame with the installed package. Then push both edges of the rail frame firmly until it locks in place. 4 Align and install the carrier frame with package into the slot on the rail frame. 1 1 2 2 3 3 2 By placing your both index fingers on the sides on the metal handle, pull to release the rail frame. Then lift the rail frame to its fully open position. 7 Close the force frame. Then use a T20 Torx screwdriver to tighten the screws to secure the force frame in a sequential order (123). 1 1 2 2 3 3 NOTE: During installation, observe the following: make sure to push the carrier frame with package towards the end of the rail frame until it clicks into place. do not drop the carrier frame or touch the package pad to avoid component damage. 2 Tighten the four screws in a diagonal sequence to secure the heat sink. 1 Install the CPU heatsink. 3 10 9 4 5 6 7 2 1 4 5 6 3 (10) Hot-Swappable 2.5” SATA 6G NVMe Trays (10) Hot-Swappable 2.5” SATA 6G HDD/ SSD Trays HDD Activity LED Event LED LAN1 LED 8 7 10 11 9 LAN2 LED Power LED Reset Button UID Button Power Button (2) USB 3.0 Ports 11 COM1 Port ID LED Button RJ45 LAN Port #2 (LAN2) Dedicated IPMI port (LAN3) USB3.0 (x2) VGA Port RJ45 LAN Port #1 (LAN1) NOTE: Please save and replace the PnP Cap when returning the server board for service. (4) Fan modules (1) TYAN ® S8026GM2NRE/ S8026GM2NR-LE system board (pre-installed) (1) M7106-R16-1F (1) M7106-L16-1F 4 (1) Quick Installation Guide Quick Installation Guide (1) Driver (1) Mounting ear kit (2) PSU clip (1) Air duct (2) US power cord (2) EU power cord (2) 2.5" HDD screw package FL00EUI-A (2) M.2 screw package FL00EUI-A (1) MEZZ card screw package FL00EUI-A (1) Rail kit (1) CPU heatsink (1) IO PLATE SFP KIT (1) IO PLATE X557 KIT (1) IO PLATE LAN KIT

Transcript of Transport SX GT62F-B8026 Quick Installation Guide · 2020. 4. 13. · Remove the Air Duct (1)...

  • Transport SX GT62F-B8026 Quick Installation GuideDocument # D2408 - 100/ Revision 1.0

    5 Caution

    4 I/O Ports

    1

    aa

    bbcc

    dd

    ee

    CPU Socket(P0)

    CPU Socket(P0)

    P0_D0_Umc0_Ch_D1P0_D0_Umc0_Ch_D1P0_D0_Umc0_Ch_D0P0_D0_Umc0_Ch_D0P0_D0_Umc1_Ch_C1P0_D0_Umc1_Ch_C1P0_D0_Umc1_Ch_C0P0_D0_Umc1_Ch_C0P0_D1_Umc1_Ch_B1P0_D1_Umc1_Ch_B1P0_D1_Umc1_Ch_B0P0_D1_Umc1_Ch_B0P0_D1_Umc0_Ch_A1P0_D1_Umc0_Ch_A1P0_D1_Umc0_Ch_A0P0_D1_Umc0_Ch_A0

    P0_D3_Umc0_Ch_E0P0_D3_Umc0_Ch_E0P0_D3_Umc0_Ch_E1P0_D3_Umc0_Ch_E1P0_D3_Umc1_Ch_F0P0_D3_Umc1_Ch_F0P0_D3_Umc1_Ch_F1P0_D3_Umc1_Ch_F1P0_D2_Umc1_Ch_G0P0_D2_Umc1_Ch_G0P0_D2_Umc1_Ch_G1P0_D2_Umc1_Ch_G1P0_D2_Umc0_Ch_H0P0_D2_Umc0_Ch_H0P0_D2_Umc0_Ch_H1P0_D2_Umc0_Ch_H1

    Battery Socket(CR1)

    Battery Socket(CR1)

    ff

    gghh

    AB

    C

    D

    2

    3

    4567

    8

    91011

    12

    13 14 15 16 17 18 19 20 21 22

    23

    24

    25

    26

    27

    282930

    ii iiiiiiiiii

    iviv

    vvvivi

    viivii

    viiiviii

    ixix xxxixi xiixii

    3132333435363738

    39

    4041

    Read Me First1. The Barebone User’s Manual is available for download from our Web site at http://www.tyan.com. Make sure to read all

    precautions and instructions before you start installing the server system.2. Refer all servicing to qualified personnel to avoid the risk of damage to the server system.3. Exercise normal ESD (Electrostatic Discharge) procedures during system integration. TYAN/MiTAC recommends wearing

    gloves and an anti-static wrist strap to avoid possible damage to the equipment.4. Current processor socket design places the pins on the motherboard instead of the processor itself. Exercise caution when

    installing the processors as the manufacturer’s warranty does not cover damage inflicted upon the motherboard, including damage to the CPU sockets.

    Tools Required

    1 General Information 3 System Installation

    Box Content

    Accessories

    2 Motherboard Placement

    Motherboard Placement

    Rear View

    Front View

    Install the Add-On Card (Optional)

    1 3

    Preparing the Chassis

    Read normal ESD (Electrostatic Discharge) procedures.

    Place your TYAN® Server Chassis on a flat anti-static surface to perform the following integration procedures. Read ESD procedures before reaching inside to install components.

    Open the Chassis

    2

    Minimum Hardware Requirements

    To avoid integration difficulties and possible board damage, your system must meet the following minimum requirements: • Processor: AMD EPYC SoC Series CPU with TDP up to 180W• Memory Type: (16) DDR4 DIMM slots, (8) channels with (2) DIMM slots per channel• Hard Disk Drives: (10) hot-swap 2.5” SATA 6G HDD/ SSD or NVMe • Rack Mount Kit (Industry 19" rack-mountable)

    NOTE: For an up to date list of compatible hardware, please visit the system’s support page on www.tyan.com

    Required Hardware Components

    Install the Hard Disks (2.5”)

    Remove the Air Duct

    (1) M1286G62F-BP12E-10-B8026 HDD BP (for B8026G62FE10HR only)

    (1) M1274G62B-BP12-10-B8026 HDD BP(for B8026G62FV10HR-LE only)

    Loosen the thumb screw on the back side.

    Slide to release the top cover and then remove.

    Remove the screw securing the top cover.

    1 Lift to remove the air duct.

    5 Reinsert the HDD tray into the chassis.

    3 Remove the screws securing the HDD tray bracket to the HDD tray. Then remove the HDD tray bracket.

    6 Push the locking lever firmly to secure the tray. Repeat the same procedures to install other HDD trays.

    4 Place a hard drive into the drive tray. Affix the four screws to secure the HDD.

    2 Slide the HDD tray out.1 Pull the locking lever open.

    1 2 3

    (1+1) Hot-Swappable Power Supply Modules (PSU1 / PSU2)1 I/O Ports2

    Optional OCP card4Expansion Slots3

    CPU Cover for DOA/RMA

    Locate the External I/O Port

    Phillips Screwdriver Flat-head Screwdriver Anti-Static Wrist StrapT20 Torx Screwdriver

    8

    B8026G62FE10HR SKU 1

    B8026G62FV10HR-LE SKU 2

    2 Lift to remove the riser bracket.1

    43

    5 Carefully flip the riser bracket. Then align and install the riser bracket to its slot on the chassis.

    6 Secure the riser bracket to the chassis withtwo screws.

    Insert the add-on card to the riser bracket. Make sure the add-on card is latched into the riser bracket. Then secure the add-on card to the riser bracket with a screw.

    Unscrew the riser bracket.

    Flip the riser bracket and place on the surface. Then unscrew and remove the PCI dummy bracket

    (1) M1716G75-FPB (1) Power Distribution Board

    (1) S8026GM2NR-LE Pre-installedin B8026G62FV10HR-LE sku

    (1+1) ERP1U 650W/ RPSU,80+ Platinum DPS-650AB-14 D

    (1) S8026GM2NRE pre-installedin B8026G62FE10HR sku

    CONNECTORS1 RJ45+USB3.0x2 (LAN3)2 SGPIO Header (SGPIO0)3 VGA + COM PORT (VGA_COM1)4 SGPIO Header (SGPIO1)5 Broadcom BCM5720 LAN Connector (LAN2)6 BMC SPI Socket (BMC_SOCKET1)7 Broadcom BCM5720 LAN Connector (LAN1)8 BIOS SPI Socket (BIOS_SOCKET1)9 REAR ID LED BTN (IDLED_BTN1)10 REAR FAN_2 (SYS_FAN_5)11 REAR FAN_1 (SYS_FAN_4)12 COM2 Header (COM2)13 NGFF 22x110mm Connector (NGFF2)14 Vertical Type A USB Connector

    (TYPEA_USB1)

    15 NGFF 22x110mm Connector (NGFF1)16 SATADOM Connector(SATA 3.0 signals)

    7Pin+2Power (SATADOM2)17 SATADOM Connector(SATA 3.0 signals)

    7Pin+2Power (SATADOM1)18 FPB USB2.0/USB3.0 *2 Header (USB3_FPIO1)19 PCIE 80P OCULINK CONN (OCUL6)20 PCIE 80P OCULINK CONN (OCUL8)21 PCIE 80P OCULINK CONN (OCUL7)22 PCIE 80P OCULINK CONN (OCUL3)23 PCIE 80P OCULINK CONN (OCUL4)24 PCIE 80P OCULINK CONN (OCUL5)25 FRONT FAN_3 (SYS_FAN_3)26 PCIE/SATA 80P OCULINK CONN (OCUL2)27 PCIE/SATA 80P OCULINK CONN (OCUL1)

    SLOTSA PCIE3.0 SLOT x24 (PESLOT1)B PCIE3.0 SLOT x24 (PESLOT2)C OCP 2.0 A Slot (OCP1_A)D OCP 2.0 B Slot (OCP1_B)

    28 FRONT FAN_2 (SYS_FAN_2)29 FRONT FAN_1 (SYS_FAN_1)30 CPU_FAN (CPU_FAN)31 System Fan Connector (FAN_HD1)32 Front Panel Header (FPIO_2)33 PSMI Header (PSMI_HD1)34 IPMB Header (IPMB1)35 8-pin Power Connector (PW3)36 8-pin Power Connector (PW2)37 ATX Power Connector (24p) (PW1)38 Reset Button (COLD_RST_BTN1)39 Power Button (PWR_BTN1)40 NMI Button (NMI_BTN)41 TYAN Module Header (DBG_HD1)

    JUMPERSa CMOS Clear jumper (J194)b BMC COM PORT2(RX) Jumper (J190)c BMC COM PORT2(TX) Jumper (J191)d PC BEEP Jumper (J120)e OCP CONN MUX & PRSENT select

    Jumper (3PHD11)f System RESET Jumper (J192)g J1 NVMe or SATA select Jumper (J9_13)h J2 NVMe or SATA select Jumper (J9_24)

    LEDsi FPGA_CRC_ERROR LED (LED1)ii FPGA_NSTATUS LED (LED2)iii FPGA_CONF_DONE LED (LED3)iv P0_PROCHOT_LED (LED4)v PWR_GOOD_LED (LED5)vi RESET_LED (LED7)vii NGFF1_LED (LED_M1)viii NGFF2_LED (LED_M2)ix HDD_ACT_LED (HDD_LED3)x On board BMC IPMI ALERT LED (IPMI_LED2)xi PSU_ALERT_N LED (PSMI_LED1)xii BMC Heartbeat LED (BMC_HBLED)

    Install the Memory

    1 Unlock the clips. 2 Insert the memory module. 3 Lock the clips.

    Install the Processor

    Install the CPU Heatsink

    3 Remove the external cap from the rail frame.

    5 Using your thumb and forefinger, remove the PnP cap by lifting it up vertically.

    1 Use a T20 Torx screwdriver to loosen the screws securing the force frame in a sequential order (321).NOTE: The force frame will automatically eject after the captive screws are being released.

    6 Carefully close the rail frame with the installed package. Then push both edges of the rail frame firmly until it locks in place.

    4 Align and install the carrier frame with package into the slot on the rail frame.

    11

    22

    33

    2 By placing your both index fingers on the sides on the metal handle, pull to release the rail frame. Then lift the rail frame to its fully open position.

    7 Close the force frame. Then use a T20 Torx screwdriver to tighten the screws to secure the force frame in a sequential order (123).

    11

    22

    33

    NOTE: During installation, observe the following: make sure to push the carrier frame with

    package towards the end of the rail frame until it clicks into place.

    do not drop the carrier frame or touch the package pad to avoid component damage.

    2 Tighten the four screws in a diagonalsequence to secure the heat sink.

    1 Install the CPU heatsink.

    3

    109

    4 5 6 7

    2

    1

    4

    5

    6

    3

    (10) Hot-Swappable 2.5” SATA 6G NVMe Trays

    (10) Hot-Swappable 2.5” SATA 6G HDD/ SSD Trays

    HDD Activity LED

    Event LED

    LAN1 LED

    8

    7

    10

    11

    9

    LAN2 LED

    Power LED

    Reset Button

    UID Button

    Power Button

    (2) USB 3.0 Ports11

    COM1 Port ID LED ButtonRJ45 LAN Port #2 (LAN2)

    Dedicated IPMI port(LAN3)

    USB3.0 (x2)

    VGA Port

    RJ45 LAN Port #1 (LAN1)

    NOTE: Please save and replace the PnP Cap when returning the server board for service.

    (4) Fan modules

    (1) TYAN® S8026GM2NRE/ S8026GM2NR-LEsystem board (pre-installed)

    (1) M7106-R16-1F(1) M7106-L16-1F

    4

    (1) Quick InstallationGuide

    Quick InstallationGuide

    (1) Driver(1) Mountingear kit

    (2) PSUclip

    (1) Air duct

    (2) US power cord (2) EU power cord (2) 2.5" HDDscrew package

    FL00EUI-A

    (2) M.2screw package

    FL00EUI-A

    (1) MEZZ cardscrew package

    FL00EUI-A

    (1) Rail kit

    FL00EUI-A

    (1) CPUheatsink

    (1) IO PLATESFP KIT

    (1) IO PLATEX557 KIT

    (1) IO PLATELAN KIT