TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current...

12
keep your measure under control TRANSFORMERS TRANSFORMERS INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A. INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A.

Transcript of TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current...

Page 1: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

keep your measure under control

TRANSFORMERSTRANSFORMERS

INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A.INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A.

Page 2: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

TRANSFORMERSCURRENT TRANSFORMERS

General Options

2

For measuring instruments.Mounted in self-exinguishing, plastic, strengthened cases.Isolation voltage 600 VMade as per UNE-EN 60044-1 – IEC 60044 1Frequency 50 or 60 Hz

For the proper choice of a current transformer following points must be considered:

For currents lower than 50 A it is advisable using wound primary models. For bus bar models rossing the wire through the hole a number of times multuple of the C.T. rated current, might be also possible.For instance, to measure 10 A, to 50 A transformers with 50/10=5 cable turns would be appropiate.

Dimensions of the primary cable or bus bar.

The real use power in VA at the transformer terminals. To obtain that data, add the drop in the cable (see table) to theconsumption of all equipment connected to the secundary line.

Table of losses in connection cables

(1) L= Distance from the transformer to the load

Page 3: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

CURRENT TRANSFORMERS. NARROW SECTION

Type TC 5

40 50 60 75 100 125 150 200 250

Class 0,5 - - - - 1,5 1,75, 2,5 3,75 5

Class 1 - - 1,25 2 2,5 3,5 3,5 5 7,5

Class 3 1,5 3 3,5 3,5 3,75 5 5 5 7,5

TC 5

VA

Standard Currents

0,41 kg

Type TC 5.2

150 200 250 300 400 500 600Class 0,5 1 2,5 3,5 3,5 3,5 5 5

Class 1 2 3 3,75 3,75 5 7,5 7,5

Class 3 2,5 3,5 5 5 7,5 10 10

TC 5.2Standard Currents

VA

0,41 kg

Type TC 6

150 200 250 300 400 500 600 750 800

Class 0,5 1 3,5 5 5 5 7,5 7,5 10 10

Class 1 3,5 5 7,5 7,5 7,5 10 10 15 15

Class 3 5 7,5 10 10 10 15 15 20 20

TC 6Standard Currents

VA

0,40 kg

Type TC 6.2

100 125 150 200 250 300 400 500 600

Class 0,5 1,75 3,75 5 7,5 7,5 10 10 15 15

Class 1 3,75 7,5 7,5 10 10 10 10 15 20

Class 3 7,5 10 10 10 15 15 15 20 25

VA

TC 6.2Standard Currents

0,52 kg

Standard Currents

50 60 75 100 125 150 200

Class 0,5 - - - - - 1,5 2,5

Class 1 - - - 2 2,5 2,5 5

Class 3 1 1,25 1,25 3 3,75 4 6

TC 4

VA

Type TC 4

-1

1,5

100

- Range primary currents 40 to 4.000 A - - -

-

Range output burden 1 to 60 VA Accuracy class: 0.5, 1 and 3Secondary current .../1A or .../5 A

- Passing-bar current transformer.- Indoor use.- Policarbonate with fiber-glass case.- Self-extinguishing coating V0.- Thermal class B (130ºC).

Technical specification

- Sealable secondary side terminals.- Secondary terminals IP20.- DIN Rail accessory for TC5 & TC6.- Security factor FS5.- Highest voltage for equipment, 0,72 kV.- Isolation voltage, 3 kV.- Working frequency, 50-60 Hz.- Short circuit thermal current, Ith=60 In.- Dynamic current, Idyn=2,5 Ith.- Standard: IEC 44-1, BS 2627.Fixing device for transformers type

TC5 TC5.2, TC6 and TC6.2

SERIE TC

3

TRANSFORMERS

Page 4: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

Type TC 10

1 000 1 200 1 500 1 600 2 000 2 500 3 000Class 0,5 10 10 15 15 15 15 15Class 1 15 15 20 20 20 20 20Class 3 20 20 20 25 25 30 30

Type TC 12

1 500 1 600 2 000 2 500 3 000 4 000

Class 0,5 15 15 15 20 30 35

Class 1 20 20 20 30 40 40

Class 3 30 30 30 40 60 60

TC 12

0,85 kg

1 200101520

200 300 400 600 800500Standard CurrentsTC 10

1 2,5 2,5 7,5 7,552,5 5 5 10 107,55 7,5 7,5 15 1510

Type TC 8

400 500 600 750 800 1 000 1 200 1 500 1 600Class 0,5 5 7,5 10 15 15 15 15 15 15Class 1 7,5 10 15 20 20 20 20 20 20Class 3 15 20 25 25 30 30 30 30 30

TC 8Standard Currents

VA

Type TC 8.30,40 kg

400 500 600 750 800 1 000Class 0,5 15 15 15 20 25 25Class 1 20 20 20 25 30 30Class 3 25 25 25 30 35 35

TC 8.3Standard Currents

VA

300200 1 250152030

12,5 5

2,55

7,5

300152025

250101525

200152025

VV

AV

3 200

30

40

60

1 250

10

15

20

1 200

10

15

20

1 000

10

15

20

8 00

10

15

20

Standard Currents

VA

0,80 kg

0,60 kg

SERIE TCH Special applications, laboratory.

4

TRANSFORMERSCURRENT TRANSFORMERS. NARROW SECTION

CURRENT TRANSFORMERS. NARROW SECTION. HIGH ACCURACY

Fixing device for transformers type TC5 TC5.2, TC6 and TC6.2

Technical specification

- Range primary currents 100 to 4.000 A - - -

-

Range output burden 1 to 30 VA Accuracy class: 0.2S, 0,2 and 0.5SSecondary current .../1A or .../5 A

- Passing-bar current transformer.- Indoor use.- Policarbonate with fiber-glass case.- Self-extinguishing coating V0.- Thermal class B (130ºC).

- Sealable secondary side terminals.- Secondary terminals IP20.- DIN Rail accessory for TC5 & TC6.- Security factor FS5.- Highest voltage for equipment, 0,72 kV.- Isolation voltage, 3 kV.- Working frequency, 50-60 Hz.- Short circuit thermal current, Ith=60 In.- Dynamic current, Idyn=2,5 Ith.- Standard: IEC 44-1, BS 2627.

100 150 200 250 300 400

Class 0,2S 1 2,5 3,5 5 5 7,5

Class 0,2 1,5 3,5 5 5 5 7,5

Class 0,5S 2,5 3,5 5 5 5 7,5

Standard CurrentsTCH 6.2

VA

Type TCH 6.2

0,52 kg

125

1

1,5

2,5

60

1

1,5

2,5

50

-

0,5

-

Page 5: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

SERIE TCH

Type TCH 6

Type TCH 8

Type TCH 10

Type TCH 12

0,60 kg

0,40 kg

0,80 kg

0,85 kg

VAVA

VAVA

Class 0,2S

Class 0,2

Class 0,5S

TCH 6

Class 0,2S

Class 0,2

Class 0,5S

TCH 8

Class 0,2S

Class 0,2

Class 0,5S

TCH 10

Class 0,2S

Class 0,2

Class 0,5S

TCH 12

1,25

150

1

1,5

600

1000

1500

5

10

10

7,5

10

10

10

15

15

200

1,25

1,5

2

750

7,5

1200

10

10

10

10

10

1600

10

15

15

250

1,5

1,75

2,25

800

1500

Standard Currents

Standard Currents

7,5

10

10

Standard Currents

10

10

15

Standard Currents

300

1,75

2

2,5

2000

10

15

15

400

1000

1600

1

5

5

10

15

15

10

10

15

2500

15

20

20

500

7,5

7,5

5

1200

2000

10

15

15

10

10

15

600

5

7,5

7,5

3000

20

25

25

1500

2500

10

15

15

10

10

15

750

7,5

10

10

1600

3000

4000

25

30

30

800

7,5

10

15

15

10

10

15

10

10

600

5

10

10

750

7,5

10

10

1250

10

10

10

800

7,5

10

10

1250

10

15

15

1200

10

15

15

500

-

4

-

5

TRANSFORMERS

Special applications, laboratory.

CURRENT TRANSFORMERS. NARROW SECTION. HIGH ACCURACY

CURRENT TRANSFORMERS. GENERAL APPLICATIONS

SERIE TA

- Range primary currents 5 to 400 A - - -

-

Range output burden 15 to 30 VA Accuracy class: 0.5, 1 and 3Secondary current .../1A or .../5 A

- Indoor use.- Policarbonate with self-extinguishing V0.- Thermal class A (105ºC).- Sealable secondary terminals.- Security factor, FS5.- Highest voltage for equipment, 0,72 kV.- Isolation voltage, 3 kV.- Working frequency, 50-60 Hz.- Short circuit thermal current, Ith=60 In.- Dynamic current, Idyn=2,5 Ith.- Standard: IEC 60044-1 / UNE EN60044-1.

Technical specification

- Range primary currents: TA 400 / TA 500: 750 to 400A TA 600: 1000 to 5000A- TA 400 / TA 500: 13 to 70VA TA 600: 15 to 80VA- - -

-

Range output burden:

Accuracy class: 0.5, 1 and 3Secondary current .../1A ó .../5 A

- Indoor use.- Policarbonate with self-extinguishing V0.- Thermal class A (105ºC).- Sealable secondary terminals.- Security factor, FS5-10.- Highest voltage for equipment, 0,72 kV.- Isolation voltage, 3 kV.- Working frequency, 50-60 Hz.- Short circuit thermal current, Ith=60 In.- Dynamic current, Idyn=2,5 Ith.- Standard: IEC 60044-1 / UNE EN 60044-1.

TA 210 TA 400 / TA 500 / TA 600

Page 6: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

CURRENT TRANSFORMERS. GENERAL APPLICATIONS

SERIE TA

Type TA 210

Standard Currents5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 400

Class 0,5 15Class 1 20Class 3 30

Sealable terminal cover and fixing base included

TA 210

VA0,80 kgW

ou

nd

Pri

mar

y

Type TA 400

750 800 1000 1200 1500 2000Class 0,5 10Class 1 15Class 3 30

For 100x20 mm bus bar

TA 400

VA

Type 500

1500 2000 2500 3000 4000

Class 0,5 20Class 1 40Class 3 50

For 100x30 mm bus bar

VA

TA 500

Type TA 600

0,76 kg

0,82 kg

1,09 kg

600500400300 30005

1015

15

3040

104050

Standard Currents

12001000

Standard Currents

2040

50

2040

50

2040

50

2000 2500 3000 3200 4000 4500Class 0,5 20Class 1 30Class 3 40

TA 600

VA

150012001000800 500015

15-

15

3040

104050

Standard Currents

152030

6000

6

TRANSFORMERS

Sealable terminal cover and fixing base included

Sealable terminal cover and fixing base included

CURRENT TRANSFORMERS. DIN RAIL MOUNTING

SERIE TM / TW

Type TM 45

Fixing system: to fit onto symmetrical DIN 46 277 (EN 50 022)

1 10 15 20 25 30 40Class 0,5 2,5Class 1 5Class 3 7

TM 45

VA

0,28 kgWo

un

d P

rim

ary

5 50

Standard Currents

- Indoor use.- ABS with self-extinguishing.- Thermal class A (105ºC).- Fixing by rail DIN 46277, EN 50022.- Security factor, FS5.

Technical specification

- Isolation voltage, 3 kV.- Working frequency, 50-60 Hz.- Short circuit thermal current, Ith=60 In.- Dynamic current, Idyn=2,5 Ith.- Standard: IEC 60044-1 / UNE EN 60044-1.

- Wound primary current transformer- Range primary current 5 to 50A- Range output burden: 2,5 to 7 VA- Accuracy class 0.5, 1 and 3 - Secondary current 1 or 5 A

Cab

le

0,31 kg

Type TW 25

- Passing bar current transformer.- Range primary current 100 to 300A- Range output burden: 1,5 to 13 VA- Accuracy class 0.5, 1 and 3 - Secondary current 1 or 5 A

Fixing system: to fit onto symmetrical DIN 46 277 (EN 50 022)

TW 25 Standard Currents100 125 150 200 250 250

Class 0,5 3 4 4- - -

A Class 1 1,5 2 3 5 9V 9Class 3 3 4 5 8 11 11

Page 7: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

Type TSR

Class 0,5

0,80 kg

CURRENT ADDING TRANSFORMER

SERIE TSR

TSR-2 2 additions (5+5 / 5 A) 15 VA

TSR-3 3 additions (5+5+5 / 5 A) 15 VA

TSR-4 4 additions (5+5+5+5 / 5 A) 15 VA

TSR-5 5 additions (5+5+5+5+5 / 5 A) 15 VA

- Number of input circuits: 2, 3, 4 or 5.- Output power: 15 VA.- Thermal class A (105ºC).- Input circuit current, ln / 5 A.- Output circuit current, 5 A.- Short circuit thermal current, lth=60 ln.- Fixing by rail DIN 46277, EN 50022.- Standard: IEC 60044-1, UNE 21 088, UL94, VDE 0414.

Technical specification

7

TRANSFORMERS

SPLIT CORE CURRENT TRANSFORMERS.

SERIE TP CLIP The TP-Clip have been designed to facilitate their installation in new or already existing networks. Thanks to ist split core they may be installed without opening any cable or bus bar circuit.

The connection of the conventional Cts usually requires the interruption of the primary side circuit to pass cables bus bar through the transformer core or to connect such cables to primary terminals. The TP-Clip may be easily opened and they may be installed and connected without any supply interruption, thus saving time and installation costs.

40/1

50/1

60/1

100/1

150/1

I(A) VA I(A) VA

1

1

1

1

1

60/5

100/5

150/5

200/5

1

1

1.5

2

Rated current- Self-extinguishable UNE 21031 V0- Thermal class B(130º)- Storage temperature -40 °C to 85 °C- Relative Humidity 15% to 85% (without condensing)- Frequency Range 50Hz - 60Hz- Rated output 1VA ...2VA- Rated insulation level 3kV- Sort-time thermal current (Ith)60 In- Rated dynamic current 2,5 Ith- Highest voltage for equipment 0,72 kV a.c.-

Technical specification

New

SERIE TP- Indoor use.- Policarbonate with self-extinguishing V0.- Sealable secondary terminals.- Highest voltage for equipment, 0,72 kV.- Range output burden: 50A to 6000A- Secondary current .../1A or .../5 A

Características técnicas

- Isolation voltage, 3 kV.- Working frequency, 50-60 Hz.- Short circuit thermal current, Ith=20 In.- Dynamic current, Idyn=2,5 Ith.- High accuracy and reliability-

100 150 200 250 300 400

Class 0,5 - - - - 1,5 2,5

Class 1 - - 1,5 2 4 6

Class 3 1,5 2 2,5 4 6 10

TP 23Standard Currents

VA

TP-23TP-58TP-88TP-812TP-816

0,75 kg0,90 kg1,00 kg1,20 kg3,50 kg

125

-

-

2

75

-

-

1,5

50

-

-

1,5

200 300 400 500 600 700

Class 0,5

Class 1

Class 3

VA

250150100 750 800 1 000

1 1,5 1,5 2,5 2,5 3 3 5

2 3 3 5 5 6 7 10

4 6 10 15 17,5 18 18 20

Standard CurrentsTP 58

2,5

5

17,5

-

-

3

-

-

3

-

-

3

Page 8: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

SERIE TP400 600 750 800 1000

Class 0,5

Class 1

Class 3

TP 88500300250

1

2

4

1,5

3

6

1,5

3

10

2,5

5

15

2,5

5

17,5

3

6

18

3

7

18

5

10

20

Class 0,5

Class 1

Class 3

TP 812

VA

Standard Currents

500 600 750 800 1 000 1 200 1 250 1 500

- - 3 3 5 6 7 8

4 5 6 7 9 11 15 17

12 14 17 18 20 24 28 30

1 600 2 500

8

17

30

8

17

30

Standard Currents

1000 1500 1600 2000 2500 3000

Class 0,5

Class 1

Class 3

1250750500 3200 4000 5000

8 15

- 20

- 25

TP 816

10

15

20-

-

36000

-

-

5 15

20

25

15

20

25

15

20

25

20

25

30

20

-

-

20

25

30

20

25

30

20

-

-

Standard Currents

VAVA

CURRENT TRANSFORMERS WITH BUILT-IN CONVERTER

Output: 4...20 mASupply Voltage: 7,5...36 V c.c.Frequency: 45 a 65 Hz(Output external supply 4...20 mA)

VA

4...2

0 m

A

7,5.

..36

V

R carga

CONNECTION DIAGRAM R =MÁX

U - 6A

0,02RESISTANCE OF LOAD:

1000

500

100

7,5 26 36 V

SERIE TC 420 SERIE TC 020

TC8-420TC5-420 TC6-4200,41 kg 0,60 kg0,40 kg

Self-supplyOutput: 0...20 mAFrequency: 45 a 65 HzResistance of load: 0 to 250

Wiring diagram andmaximum load

0 - 20 mA

R

R < 250

TC8-020TC6-020

0,60 kg0,40 kg

400 500 1000 15005 10 20 50

TC5-420

Ø 20 Bar 25x5 mm

Ø 28 Bar 40x10 mm Ø 44 Bar 60x12 mm

TC6-420 TC8-420

Standard Currents (A)

40 60 75 100 125 150 200 300 50 100 200

TC6-020

Ø 28 Bar 40x10 mm

Ø 44 Bar 60x12 mm

TC8-020

Standard Currents (A)

500 1000 1500300

8

TRANSFORMERSSPLIT CORE CURRENT TRANSFORMERS.

Page 9: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

SERIE TP 420 (Split core)External supplyOutput: 4...20 mASupply Voltage: 10...28 V c.c.Frequency: 45 to 65 Hz

Type TP 420

TP 420 20x30TP 420 50x80TP 420 80x80TP 420 80x120TP 420 80x160

0,75 kg0,90 kg1,00 kg1,20 kg3,50 kg

Sealable connection terminal box

Metallic holders for fixing

Self-extinguishing UL94VO

20x30 50x80 80x80 80x120 80x160

4 000750 1 000 1 500 2 000 3 000

TP 420

5 10 20 50 100 200 250 500

Bar (mm x mm)

Standard Currents (A)

SERIE TCM 420 - TCB 420

Serie with supply of 230VAC (Internal supply)

Type TCM 420 for fixing at panel bottom or onto DIN 46277

Closed core type TCB 420

Output 4-20 mA

Frequency 45 to 65 Hz

Máxima Carga:

TCM 420 ( 25) 200

TCM 420 ( 35) 300

TCB 420 300

Type TCM 420

Type TCB 420

0,39 kg0,52 kg0,85 kg

TCB 420 35TCB 420 TCB 420

Ø Ø 70Ø 105

0,5 kg

Sealable connection terminal box

Standard Currents (A)

2,5 5 10

TCM 420

Ø 25

50

TCM 420

Ø 35

100 200 100 200 300

Ø 35 Ø 70 Ø 105

TCB 420 TCB 420 TCB 420

2,5 5 10 50 100 200 300 100 250 500 750 250 500 750 1000 1500

Standard Currents (A)

CURRENT TRANSFORMERS FOR ENERGY METERS

SERIE TRMCTechnical Specification

- Enclosure of self-extinguishing V0, synthetic resin (TRMC400).- Policarbonate with self-extinguishing V0 (TRMC210).- Thermal class B (130ºC).- Sealable secondary side terminals.- Security factor, FS-5.- Highest voltage for equipment, 0,72 kV.

- Isolation voltage, 3 kV.- Working frequency, 50-60 Hz.- Short circuit thermal current, lth=60 ln.- Dynamic current, ldyn=2,5 lth.- Standard: IEC 60044-1 / UNE EN60044-1.

9

TRANSFORMERSCURRENT TRANSFORMERS WITH BUILT-IN CONVERTER

Metallic holders for fixing

Self-extinguishing UL94VO

Page 10: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

Type TRMC210

Type TRMC400

Class 0,5

Class 0,5S

750

Standard Currents

1 000 2 000

15

VA10

TRMC 400

100 150 200 300 400 500 600

Class 0,5

Class 0,5S15

Standard Currents

VA

10

TRMC 210

1,5 kg

1,65 kg

Wo

un

d P

rim

ary

Bar

100

x20

1 500

Rango de intensidades de corriente deprimario 100 a 600 A

Classs de precisión 0.5S y 0.5Rango de potencias 10 a 15 VA

Intensidades de secundario 1 ó 5 A

Transformador de primario bobinado

Rango de intensidades de corriente deprimario 750 a 2000 A

Classs de precisión 0.5S y 0.5Rango de potencias 10 a 15 VA

Intensidades de secundario 1 ó 5 A

Transformador Type Bar pasante

PROTECTION CURRENT TRANSFORMERS.

Type TRP40

Type TRP60

Type TRP80

Type TRP100

100

5

TRP 40

VA

1502,5

TRP 60

VA

2505

TRP 80

VA

750

5

TRP 100

VA

9,1 kg

4,9 kg

6,3 kg

6,4 kg

Technical specification

- Range primary currents: 100 to 5000A-

- Passing-bar current transformer.- Indoor use.- Enclosure of self-extinguishing V0, synthetic resin.- Thermal class B (130ºC).

Range output burden 2,5 to 35 VA - Accuracy class: 5P10 and 5P20- Secondary current .../1A or .../5A

- Sealable secondary side terminals.- Highest voltage for equipment, 0,72 kV.- Isolation voltage, 3 kV.- Working frequency, 50-60 Hz.- Short circuit thermal current, lth=60 ln.- Dynamic current, ldyn=2,5 lth.- Standard: IEC 60044-1 / UNE EN60044-1.-

150 200 250 300 400 500

5 10 10 15 20 25

Standard Currents

200 250 300 400 500 600 750 1 0002,5 5 5 7,5 10 10 15 20

300 400 500 600 800 1 000 1 200 1 500 1 600 1 8005 7,5 10 10 15 20 25 30 30 35

1 000 1 200 1 600 1 800 2 000 2 500 3 000

7,5 10 10 15 15 15 20

Standard Currents

Standard Currents

Standard Currents

10

TRANSFORMERSCURRENT TRANSFORMERS FOR ENERGY METERS

Page 11: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

PROTECTION CURRENT TRANSFORMERS.

7,1 kg

Type TRP140

1 000

5

TRP 140

VA

1 5005VA

TRP 180

Type TRP180

8,9 kg

1 250 1 500 2 000 2 500 3 000 4 000

5 10 10 10 15 15

2 000 2 500 3 000 4 000 5 0007,5 10 10 15 15

Standard Currents

Standard Currents

MEASUREMENT RESIN CASE CURRENT TRANSFORMERSCaracterísticas técnicas

- Range primary currents: 60 to 5000A-

- Passing-bar current transformer.- Indoor use.- Enclosure of self-extinguishing V0, synthetic resin.- Thermal class B (130ºC).

Range output burden 2,5 to 35 VA - Accuracy class: 0,5 and 1- Secondary current .../1A or .../5A

- Sealable secondary side terminals.- Highest voltage for equipment, 0,72 kV.- Isolation voltage, 3 kV.- Working frequency, 50-60 Hz.- Short circuit thermal current, lth=60 ln.- Dynamic current, ldyn=2,5 lth.- Standard: IEC 60044-1 / UNE EN60044-1.-

Type TRM30

Type TRM40

Type TRM60

75 100 150 200 250 300 400Class 0,5 10 15 20 25

Class 1 2 5 5

TRM 30

VA

-

-

100 150 200 250 300 400 500 600 800Class 0,5 - 5 7,5 10 15 20 25 30 35

Class 1 2,5VA

TRM 40

-

250 300 400 500 600 800 1 000 1 200

VA Class 0,5 5 7,5 10 15 20 25 30 35

TRM 60

1,2 kg

1,2 kg

1,4 kg

Standard Currents

Standard Currents

5 7,5 10 15 20 25 30

500 600 750 1000 1500 2000 2500Class 0,5

TRM 80

VA

Standard Currents

Type TRM80

1,4 kg

Standard Currents

11

TRANSFORMERS

Page 12: TRANSFORMERS - Microsoft · - Standard: IEC 60044-1 / UNE EN 60044-1. - Wound primary current transformer - Range primary current 5 to 50A - Range output burden: 2,5 to 7 VA - Accuracy

Instrumentación Industrial ZURC, SAC/Innovació 3, P.l. Can Mitjans, 08232 Viladecavalls (Barcelona) - SPAIN

Tel. (+34) 93 784 84 30 - Fax (+34) 93 784 84 35 e-mail: [email protected] - web: www.zurc.com

12

Type TRM30

75 100 150 200 250 300 400Class 0,5 10 15 20 25

Class 1 2 5 5

TRM 30

VA

-

-

1,2 kgStandard Currents

1,7 kg

2,3 kg

2,5 kg

Type TRM100

15 25

750 1000 1250 1500 2000 2500 3000Class 0,5

TRM 100

VA

Standard Currents

20

15 35

1000 1250 1500 2000 2500 3000 4000Class 0,5

TRM 140

VA

Standard Currents

30

Type TRM140

20 25

Type TRM180

15

1250 1500 2000 2500 3000 4000 5000Class 0,5

TRM 180

VA

Standard Currents

20

TRANSFORMERSMEASUREMENT RESIN CASE CURRENT TRANSFORMERS

** FOR SPECIAL TRANSFORMERS NOT LISTED, PLEASE CONSULT **