PIPENET VISION TRAINING MANUAL TRANSIENT: CHAPTER 4 PAGE 9 OF 37 REVISION 2.1, SEP 2010 4.4 Pump Curve The pump in the network is modelled using a simple pump in the Transient Module. Its pump curve is input in the form of data points, which are shown in the following table. Flow Rate (m 3 /hr) Head (m of fluid) 0 69.5 10000 60 18000 50 25000 30 This data is entered into the dialog box obtained from Libraries | Pumps – Coeffs. unknown, with the fitted curve being a quadratic.
description
Trans Chapter4 9
Transcript of Trans Chapter4 9
PIPENET VISION TRAINING MANUAL TRANSIENT: CHAPTER 4 PAGE 9 OF 37 REVISION 2.1, SEP 2010
4.4 Pump Curve
The pump in the network is modelled using a simple pump in the Transient Module. Its pump curve is input in the form of data points, which are shown in the following table.
Flow Rate (m3/hr) Head (m of fluid)
0 69.5
10000 60
18000 50
25000 30
This data is entered into the dialog box obtained from Libraries | Pumps – Coeffs. unknown, with the fitted curve being a quadratic.