Variable Speed ModularMulti-position Air Handlers2-5 Tons
TAM7A0A24H21SATAM7A0B30H21SATAM7A0C36H31SATAM7A0C42H31SATAM7A0C48H41SATAM7A0C60H51SA
PUB. NO. 22-1847-02

2 Pub. No. 22-1847-02
Featuresand Benefits
© 2011 Trane
• Air-Tite II™ cabinet – 2% or less air leakage – Precision applied - durable door
seals – Specially designed air seal around
refrigerant, condensate and conduit connections
– Double wall foamed cabinet system – ≥ R-4.2 insulating value – No loose fiber design – Smooth cleanable interior design – Sweat eliminating design – Composite foamed cabinet doors – Water proof cabinet design – Integrated horizontal drain pans – Modular cabinet with 5/16" allen
wrench "quick latch" design • Multi-position up/down flow horizontal
left/right• Side return option (sold as accessory)• Control board protection pocket built
into cabinet wall• Alert port to view control board codes
without door removal
• Alert code notification• Low voltage terminal connection point• Quarter turn phillips head door fasten-
ers• Vortica® blower with polarized plug
connections and integrated slide deck for easy removal
• Aluminum coil with integrated slide deck for easy removal and polar-ized plug connections on coil EEV
• Patented enhanced coil fin• Electronic Expansion Valve (EEV) with
low ambient and low superheat compressor protection
• Dual refrigerant compatible as shipped• Slide in electric heaters with polarized
plug connections (sold as accessory)
• Slide in hot water coils with polarized plug connections (sold as accessory)
• UVC light kit with safety switch and polarized plug connections (sold as accessory)
• Labeled panels and connections• Molded in 1" standard filter rail• Variable speed ECM motor• Soft start fan motor operation• Comfort RTM mode• Built in fan delay modes• Maximum width of 23.5"• Compact 20.8" depth with doors
removed• Two tone color• Fused 24v power• Safety door switch• 1-year warranty • 10-year warranty registered• Optional extended warranty avail-
able

Pub. No. 22-1847-02 3
Contents
Features and Benefits 2Optional Equipment 4
“Air-Tite II™” Features and Benefits 5
General Data 6TAM7A0A24H21SA 6TAM7A0B30H21SA 6TAM7A0C36H31SA 6TAM7A0C42H31SA 6TAM7A0C48H41SA 6TAM7A0C60H51SA 6
Performance Data 7Electrical Data 19
Field Wiring 26
Convertibility 30
Dimensions 31

4 Pub. No. 22-1847-02
Optional Equipment
Accessory Number Description Fits Cabinet Size
BAYEVAC05BK1AA Electric Heater, 5kW, Breaker, RS-485 Control, 1 Ph A to C
BAYEVAC05LG1AA Electric Heater, 5kW, Lugs, RS-485 Control, 1 Ph A to C
BAYEVAC08BK1AA Electric Heater, 8kW, Breaker, RS-485 Control, 1 Ph A to C
BAYEVAC08LG1AA Electric Heater, 8kW, Lugs, RS-485 Control, 1 Ph A to C
BAYEVAC10BK1AA Electric Heater, 10kW, Breaker, RS-485 Control, 1 Ph A to C
BAYEVAC10LG1AA Electric Heater, 10kW, Lugs, RS-485 Control, 1 Ph A to C
BAYEVBC15BK1AA Electric Heater, 15kW, Breaker, RS-485 Control, 1 Ph B to C
BAYEVBC20BK1AA Electric Heater, 20kW, Breaker, RS-485 Control, 1 Ph B to C
BAYEVCC25BK1AA Electric Heater, 25kW, Breaker, RS-485 Control, 1 Ph C
BAYEVAC10LG3AA Electric Heater, 10kW, Lugs, RS-485 Control, 3 Ph A to C
BAYEVBC15LG3AA Electric Heater, 15kW, Lugs, RS-485 Control, 3 Ph B to C
BAYSUPFLGAA Supply Duct Flange A A
BAYSUPFLGBA Supply Duct Flange B B
BAYSUPFLGCA Supply Duct Flange C C
BAYRETFLGAA Return Duct Flange A A
BAYRETFLGB Return Duct Flange B B
BAYRETFLGCA Return Duct Flange C C
TASB175 Plenum Stand A A
TASB215 Plenum Stand B B
TASB235 Plenum Stand C C
BAYSRKIT100A Side Return Kit A to C
BAYICSKIT01A Internal Condensate Switch Kit A to C
BAYHHKIT001A Horizontal Hanger Kit A to C
BAYUVCLK001A UVC Lights A to C
BAYLVKIT100A Low Voltage Conduit Entry Kit A to C
BAYSPEKT200A Single Power Entry Kit A to C
BAYWVAA05SC0AAA Hydronic Coil - 50,000 BTUH - Slide-in A to A
BAYWVBB07SCAAA Hydronic Coil - 70,000 BTUH - Slide-in B to B
BAYWVCC08SC1AAA Hydronic Coil - 80,000 BTUH - Slide-in C to C
BAYWVCC10SC1AAA Hydronic Coil - 100,000 BTUH - Slide-in C to C
BAYWACC11SC1AA Hydronic Coil - 110,000 BTUH - Add-on C to C
OPTIONAL EQUIPMENT FOR AIR HANDLERS

Pub. No. 22-1847-02 5
“Air-Tite II™”Features and Benefits
5 Conduit Connections
r Integrated Horizontal Drain Pans
6 Quarter Turn Door Fasteners
7 Alert Code Viewport
e Compact 20.8” Depth with Doors Removed
1 AirTite IITM Cabinet
2 Precision Durable Door Seals
q Electronic Expansion Valve (EEV)
3 Refrigeration Connections
9 All Aluminum Coil
t Safety Door Switch
4 Condensate Connections
w Maximum width is 23.5”
8 VorticaTM Blower and Deck
0 Labeled Panels and Connections
1 AirTite IITM Cabinet - Double wall foamed cabinet system - Waterproof Cabinet Design - ≥ R-4.2 Insulating Value - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Design - Smooth Cleanable Cabinet Design2 Precision Durable Door Seals3 Refrigeration Connections4 Condensate Connections5 Conduit Connections - Conduit Connections on Left,
Right, and Top6 Quarter Turn Door Fasteners7 Alert Code Viewport - Alert Codes can be Viewed Without Door Removal - Control Protection Pocket
8 VorticaTM Blower and Deck - Polarized Plug on Blower
9 All Aluminum Coil - Integrated Slide Deck for Easy Removal - Polarized Plug connections on Coil EEV - Patented Enhanced Coil Fin0 Labeled Panels and Connectionsq Electronic Expansion Valve (EEV) - Low Ambient and Low Superheat Protection - Dual Refrigerant Compatible as Shippedw Maximum width is 23.5”e Compact 20.8” Depth with Doors Removedr Integrated Horizontal Drain Panst Safety Door Switch - Fused 24V Powery 5/16” Allen Wrench “Quick Latch” Modular
Cabinet

6 Pub. No. 22-1847-02
GeneralData
PRODUCT SPECIFICATIONSMODEL TAM7A0A24H21SARATED VOLTS/PH/HZ. 200-230/1/60RATINGS 1 See O.D. SpecificationsINDOOR COIL — Type Plate FinRows — F.P.I. 3 - 14Face Area (sq. ft.) 3.67Tube Size (in.) 3/8Refrigerant Control EEVDrain Conn. Size (in.) 2 3/4 NPTDUCT CONNECTIONS See Outline DrawingINDOOR FAN — Type CentrifugalDiameter-Width (In.) 11 X 8No. Used 1Drive - No. Speeds Direct - VariableCFM vs. in. w.g. See Fan Performance TableNo. Motors — H.P. 1 - 1/2Motor Speed R.P.M. Variable ECMVolts/Ph/Hz 208-230/1/60F.L. Amps 3.0FILTERFilter Furnished? NoType Recommended ThrowawayNo.-Size-Thickness 1 - 16 X 20 - 1 in.REFRIGERANT R-410ARef. Line Connections BrazedCoupling or Conn. Size — in. Gas 3/4Coupling or Conn. Size — in. Liq. 3/8DIMENSIONS H x W x DCrated (In.) 51-1/2 x 19 x 23-1/2Uncrated 49-7/8 x 17-1/2 x 21-3/4WEIGHTShipping (Lbs.) / Net (Lbs.) 127/116
TAM7A0B30H21SA200-230/1/60
See O.D. SpecificationsPlate Fin
3 - 145.043/8
EEV 3/4 NPT
See Outline DrawingCentrifugal
11 X 101
Direct - VariableSee Fan Performance Table
1 - 1/2Variable ECM208-230/1/60
3.0
NoThrowaway
1 - 20 X 20 - 1 in.R-410ABrazed
3/43/8
H x W x D56-1/2 x 23 x 23-1/2
55-11/16 x 21-5/16 x 21-3/4
150/138
TAM7A0C36H31SA200-230/1/60
See O.D. SpecificationsPlate Fin
3 - 145.503/8
EEV 3/4 NPT
See Outline DrawingCentrifugal
11 X 101
Direct - VariableSee Fan Performance Table
1 - 1/2Variable ECM208-230/1/60
3.0
NoThrowaway
1 - 22 X 20 - 1 in.R-410ABrazed
7/83/8
H x W x D57-1/4 x 25-1/4 x 23-1/2
56-15/16 x 23-1/2 x 21-3/4
157/146
PRODUCT SPECIFICATIONSMODEL TAM7A0C42H31SARATED VOLTS/PH/HZ. 200-230/1/60RATINGS 1 See O.D. SpecificationsINDOOR COIL — Type Plate FinRows — F.P.I. 4 - 14Face Area (sq. ft.) 5.04Tube (in.) 3/8Refrigerant Control EEV Drain Conn. Size (in.) 2 3/4 NPTDUCT CONNECTIONS See Outline DrawingINDOOR FAN — Type CentrifugalDiameter-Width (In.) 11 X 10No. Used 1Drive - No. Speeds Direct - VariableCFM vs. in. w.g. See Fan Performance TableNo. Motors — H.P. 1 - 1/2Motor Speed R.P.M. Variable ECMVolts/Ph/Hz 208-230/1/60F.L. Amps 3.0FILTERFilter Furnished? NoType Recommended ThrowawayNo.-Size-Thickness 1 - 22 X 20 - 1 in.REFRIGERANT R-410ARef. Line Connections BrazedCoupling or Conn. Size — in. Gas 7/8Coupling or Conn. Size — in. Liq. 3/8DIMENSIONS H x W x DCrated (In.) 57-1/4 x 25-1/4 x 23-1/2 Uncrated 56-15/16 x 23-1/2 x 21-3/4WEIGHTShipping (Lbs.) / Net (Lbs.) 162/151
TAM7A0C48H41SA200-230/1/60
See O.D. SpecificationsPlate Fin
4 - 145.963/8
EEV 3/4 NPT
See Outline DrawingCentrifugal
11 X 101
Direct - VariableSee Fan Performance Table
1 - 3/4Variable ECM208-230/1/60
4.2
NoThrowaway
1 - 22 X 20 - 1 in.R-410ABrazed
7/83/8
H x W x D62-3/4 x 25-1/4 x 23-1/2 61-3/4 x 23-1/2 x 21-3/4
175/163
TAM7A0C60H51SA200-230/1/60
See O.D. SpecificationsPlate Fin
4 - 145.963/8
EEV 3/4 NPT
See Outline DrawingCentrifugal
11 X 101
Direct - VariableSee Fan Performance Table
1 - 1Variable ECM208-230/1/60
5.5
NoThrowaway
1 - 22 X 20 - 1 in.R-410ABrazed
7/83/8
H x W x D62-3/4 x 25-1/4 x 23-1/2
61-11/16 x 23-1/2 x 21-3/4
175/163
1 These Air Handlers are AHRI. certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.
2 3/4" Male Plastic Pipe (Ref.: ASTM 1785-76)

Pub. No. 22-1847-02 7
PerformanceData
TAM7A0A24 AIRFLOW PERFORMANCE TABLE - CONSTANT CFM
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA
*AM7A0A24H21SAA 638/713 638/900 675/900 600/713 -- -- --
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
AIRFLOW PERFORMANCE - CONSTANT CFM*AM7A0A24 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE HEATING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9
1.5 tons
360 CFM/ton
CFMWatts
54238
54767
548101
547137
541175
390 CFM/ton
CFMWatts
58646
59980
600115
599153
595192
380 CFM/ton
CFMWatts
57443
58375
587110
588148
581185
410 CFM/ton
CFMWatts
61853
63388
636124
637163
629202
400 CFM/ton
CFMWatts
60549
61882
624119
625158
618196
430 CFM/ton
CFMWatts
65059
66596
669134
672174
660212
420 CFM/ton
CFMWatts
63655
65190
659128
660168
653207
450 CFM/ton
CFMWatts
68166
696104
703144
704185
696225
2 tons †
360 CFM/ton
CFMWatts
72375
743115
754158
756201
748242
390 CFM/ton
CFMWatts
78094
800137
809182
811227
802268
380 CFM/ton
CFMWatts
76186
782128
793172
796216
788259
410 CFM/ton
CFMWatts
818106
838151
848198
851244
842287
400 †CFM/ton
CFMWatts
79997
820141
832187
835233
827276
430 CFM/ton
CFMWatts
856119
876167
887215
889262
881307
420 CFM/ton
CFMWatts
836109
858155
870203
873250
866294
450 CFM/ton
CFMWatts
894134
913183
925233
927282
920327
2.5 tons
360 CFM/ton
CFMWatts
892130
914179
927229
930278
923324
390 CFM/ton
CFMWatts
964164
986218
997271
1000322
992370
380 CFM/ton
CFMWatts
939149
962201
974253
978304
971351
410 CFM/ton
CFMWatts
1013188
1034244
1045299
1049353
1040400
400 CFM/ton
CFMWatts
986170
1009225
1022279
1026332
1019380
430 CFM/ton
CFMWatts
1063214
1083273
1095331
1097385
1089434
420 CFM/ton
CFMWatts
1035194
1058251
1071308
1074362
1066411
450 CFM/ton
CFMWatts
1114243
1135305
1145365
1145420
1135469
3 tons
360 CFM/ton
CFMWatts
1065209
1088269
1101327
1103382
1095431
390 CFM/ton
CFMWatts
1160272
1181337
1190397
1189453
1157486
380 CFM/ton
CFMWatts
1126244
1149307
1160367
1161423
1151472
410 CFM/ton
CFMWatts
1225317
1244384
1249444
1230486
1146477
400 CFM/ton
CFMWatts
1190285
1211350
1220412
1218467
1164483
430 CFM/ton
CFMWatts
1291368
1305434
1298486
1217476
1135468
420 CFM/ton
CFMWatts
1255331
1273397
1278459
1237483
1151475
450 CFM/ton
CFMWatts
1355422
1361485
1285475
1206467
1124460
NOTES: 1. * Models start with "A" or "T" 2. † Factory Setting 3. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 4. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
TAM7A0A24 MINIMUM HEATER CFM TABLE
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.

8 Pub. No. 22-1847-02
AIRFLOW PERFORMANCE - CONSTANT TORQUE MODE (See Switch S2-5)*AM7A0A24 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9
1.5 tons
360 CFM/ton
CFMWatts
65259
55971
40778
n/a n/a
380 CFM/ton
CFMWatts
67965
59378
46487
16794
n/a
400 CFM/ton
CFMWatts
70571
62685
51396
325101
n/a
410 CFM/ton
CFMWatts
73178
65893
556105
406112
n/a
2 tons †
360 CFM/ton
CFMWatts
809101
746118
666133
563144
428153
380 CFM/ton
CFMWatts
843113
784131
710146
617159
500168
400 †CFM/ton
CFMWatts
877125
821144
751161
666174
561183
410 CFM/ton
CFMWatts
911139
858158
792175
712189
615199
2.5 tons
360 CFM/ton
CFMWatts
979168
930189
869207
796222
709232
380 CFM/ton
CFMWatts
1024190
976211
918230
849244
766255
400 CFM/ton
CFMWatts
1070215
1023236
967255
901270
821280
410 CFM/ton
CFMWatts
1118242
1072264
1018282
953297
877307
3 tons
360 CFM/ton
CFMWatts
1148261
1102282
1048301
985315
910325
380 CFM/ton
CFMWatts
1209301
1164322
1111341
1050355
978364
400 CFM/ton
CFMWatts
1271347
1227368
1175386
1115399
1046408
410 CFM/ton
CFMWatts
1334397
1289418
1239435
1180448
1113455
NOTES: 1. * Models start with "A" or "T" 2. † Factory Setting 3. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 4. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
TAM7A0A24 AIRFLOW PERFORMANCE TABLE - CONSTANT TORQUE MODE
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA
*AM7A0A24H21SAA 638/713 638/900 675/900 600/713 -- -- --
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
TAM7A0A24 MINIMUM HEATER CFM TABLE
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.
PerformanceData

Pub. No. 22-1847-02 9
TAM7A0B30 AIRFLOW PERFORMANCE TABLE - CONSTANT CFM
PerformanceData
TAM7A0B30 MINIMUM HEATER CFM TABLE
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA
*AM7A0B30H21SAA 723/808 723/1020 765/1020 680/808 765/1063 850/1105 --
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
AIRFLOW PERFORMANCE - CONSTANT CFM*AM7A0B30 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE HEATING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9
1.5 tons
360 CFM/ton
CFMWatts
59130
56058
53387
509118
482150
390 CFM/ton
CFMWatts
63035
60965
58896
566128
540161
380 CFM/ton
CFMWatts
61833
59362
56993
547125
524158
410 CFM/ton
CFMWatts
65738
63970
621102
601136
578169
400 CFM/ton
CFMWatts
64537
62467
60499
584132
562166
430 CFM/ton
CFMWatts
68342
66975
653109
636143
614177
420 CFM/ton
CFMWatts
65938
63969
620102
602136
581170
450 CFM/ton
CFMWatts
70945
69880
685115
669151
649186
2 tons †
360 CFM/ton
CFMWatts
75051
74187
731125
719163
704200
390 CFM/ton
CFMWatts
80060
79799
791139
781180
766219
380 CFM/ton
CFMWatts
78457
77995
771134
762174
748213
410 CFM/ton
CFMWatts
83466
834107
830150
822192
810233
400 †CFM/ton
CFMWatts
81862
816103
811144
803186
792227
430 CFM/ton
CFMWatts
86873
871116
869161
864205
853248
420 CFM/ton
CFMWatts
83566
834107
831150
824192
813234
450 CFM/ton
CFMWatts
90280
908126
908172
905219
895263
2.5 tons
360 CFM/ton
CFMWatts
90480
908125
909172
907219
898264
390 CFM/ton
CFMWatts
96795
977145
982196
982247
974295
380 CFM/ton
CFMWatts
94789
955138
959188
958237
951285
410 CFM/ton
CFMWatts
1012106
1025160
1033214
1034268
1027318
400 CFM/ton
CFMWatts
991100
1002152
1009205
1010257
1003307
430 CFM/ton
CFMWatts
1057119
1074176
1084234
1087290
1078342
420 CFM/ton
CFMWatts
1013106
1026159
1034214
1036268
1029318
450 CFM/ton
CFMWatts
1104133
1124194
1136255
1139314
1128366
3 tons
360 CFM/ton
CFMWatts
1063120
1080177
1091236
1094292
1085344
390 CFM/ton
CFMWatts
1147147
1170211
1184276
1185336
1170389
380 CFM/ton
CFMWatts
1120137
1140199
1153262
1156321
1444374
410 CFM/ton
CFMWatts
1208168
1233238
1247306
1245367
1223418
400 CFM/ton
CFMWatts
1179157
1202224
1216290
1216351
1198403
430 CFM/ton
CFMWatts
1271193
1298267
1309337
1300398
1271446
420 CFM/ton
CFMWatts
1210168
1233237
1247305
1245306
1224417
450 CFM/ton
CFMWatts
1338221
1363299
1368369
1350427
1314472
NOTES: 1. * Models start with "A" or "T" 2. † Factory Setting 3. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 4. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.

10 Pub. No. 22-1847-02
AIRFLOW PERFORMANCE - CONSTANT TORQUE MODE (See Switch S2-5)*AM7A0B30 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9
1.5 tons
360 CFM/ton
CFMWatts
68541
53856
29963
n/a n/a
380 CFM/ton
CFMWatts
71145
57260
35968
n/a n/a
400 CFM/ton
CFMWatts
73849
60565
41073
n/a n/a
420 CFM/ton
CFMWatts
75150
62167
43476
n/a n/a
2 tons †
360 CFM/ton
CFMWatts
84066
72685
57596
34499
n/a
380 CFM/ton
CFMWatts
87472
76492
622104
419107
n/a
400 †CFM/ton
CFMWatts
90879
802100
667113
484117
n/a
420 CFM/ton
CFMWatts
92483
820104
689118
513122
180132
2.5 tons
360 CFM/ton
CFMWatts
1017105
921129
804144
658150
454148
380 CFM/ton
CFMWatts
1061117
968142
856158
719165
538163
400 CFM/ton
CFMWatts
1106131
1016156
908174
779182
614180
420 CFM/ton
CFMWatts
1129138
1040164
934182
808190
650189
3 tons
360 CFM/ton
CFMWatts
1182156
1095182
993201
873211
727210
380 CFM/ton
CFMWatts
1241178
1157205
1059225
945235
809236
400 CFM/ton
CFMWatts
1304203
1221231
1127252
1018263
890265
420 CFM/ton
CFMWatts
1337217
1255246
1162267
1055279
931281
NOTES: 1. * Models start with "A" or "T" 2. † Factory Setting 3. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 4. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
PerformanceData
TAM7A0B30 AIRFLOW PERFORMANCE TABLE - CONSTANT TORQUE MODE
TAM7A0B30 MINIMUM HEATER CFM TABLE
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA
*AM7A0B30H21SAA 723/808 723/1020 765/1020 680/808 765/1063 850/1105 --
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.

Pub. No. 22-1847-02 11
PerformanceData
TAM7A0C36 AIRFLOW PERFORMANCE TABLE - CONSTANT CFM
TAM7A0C36 MINIMUM HEATER CFM TABLE
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA
*AM7A0C36H31SAA 876/979 876/1236 927/1236 824/979 927/1288 1030/1339 1236/1442
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
AIRFLOW PERFORMANCE - CONSTANT CFM*AM7A0C36 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE HEATING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9
2 tons
350 CFM/ton
CFMWatts
72444
70477
694111
695148
698185
400 CFM/ton
CFMWatts
81357
79794
794133
799174
806215
370 CFM/ton
CFMWatts
75949
74484
738120
740158
742197
420 CFM/ton
CFMWatts
84963
837102
835142
841185
849228
390 CFM/ton
CFMWatts
79554
78491
780129
783169
786209
440 CFM/ton
CFMWatts
88469
876110
876153
883197
891242
410 CFM/ton
CFMWatts
83060
82399
822139
824180
827222
450 CFM/ton
CFMWatts
90272
895114
897158
902203
912249
2.5 tons
350 CFM/ton
CFMWatts
87968
876110
877153
881197
884240
400 CFM/ton
CFMWatts
99291
991138
998188
1005237
1014287
370 CFM/ton
CFMWatts
92377
924121
927167
932213
936258
420 CFM/ton
CFMWatts
1036101
1040152
1048204
1057256
1064307
390 CFM/ton
CFMWatts
96886
971133
977181
983230
987277
440 CFM/ton
CFMWatts
1081113
1089167
1099221
1110277
1116330
410 CFM/ton
CFMWatts
101296
1020146
1028197
1034248
1039298
450 CFM/ton
CFMWatts
1105119
1113174
1125231
1136287
1141341
3 tons †
350 CFM/ton
CFMWatts
1036102
1044153
1053206
1060257
1064308
400 CFM/ton
CFMWatts
1175140
1189200
1203261
1214321
1215377
370 † CFM/ton
CFMWatts
1090116
1102171
1114227
1122282
1123334
420 CFM/ton
CFMWatts
1234159
1251223
1267288
1275351
1272406
390CFM/ton
CFMWatts
1145132
1161191
1176251
1184309
1184363
440 CFM/ton
CFMWatts
1295180
1315250
1331318
1335381
1325435
410 CFM/ton
CFMWatts
1204150
1223213
1238277
1246337
1242391
450 CFM/ton
CFMWatts
1327192
1348264
1362264
1364396
1350449
3.5 tons
350 CFM/ton
CFMWatts
1199149
1218211
1233274
1241335
1237389
400 CFM/ton
CFMWatts
1380214
1403289
1414360
1409422
1389472
370 CFM/ton
CFMWatts
1269172
1291240
1307307
1311370
1300423
420 CFM/ton
CFMWatts
1459248
1478327
1481397
1467456
1395476
390 CFM/ton
CFMWatts
1342200
1367273
1380343
1378405
1358456
440 CFM/ton
CFMWatts
1538287
1550366
1542433
1504478
1388472
410 CFM/ton
CFMWatts
1419232
1442309
1449380
1438440
1394478
450 CFM/ton
CFMWatts
1575307
1583385
1570450
1501477
1385470
NOTES: 1. * Models start with "A" or "T" 2. † Factory Setting 3. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 4. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.

12 Pub. No. 22-1847-02
AIRFLOW PERFORMANCE - CONSTANT TORQUE MODE (See Switch S2-5)*AM7A0C36 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9
2 tons
350 CFM/ton
CFMWatts
85863
70677
53085
29790
19163
370 CFM/ton
CFMWatts
89269
74784
58593
38798
84135
390 CFM/ton
CFMWatts
92475
78791
635102
460107
213120
410 CFM/ton
CFMWatts
95782
82699
683111
524117
329123
2.5 tons
350 CFM/ton
CFMWatts
102697
905116
776130
639138
488143
370 CFM/ton
CFMWatts
1067107
952127
830142
702151
565157
390 CFM/ton
CFMWatts
1110118
999139
883155
762166
634172
410 CFM/ton
CFMWatts
1153130
1047153
935170
820181
700187
3 tons †
350 CFM/ton
CFMWatts
1175137
1070160
961177
848189
731196
370 †CFM/ton
CFMWatts
1229154
1129178
1024196
916209
805217
390CFM/ton
CFMWatts
1285173
1188198
1087218
984231
877240
410 CFM/ton
CFMWatts
1343195
1249221
1152241
1051256
948264
3.5 tons
350 CFM/ton
CFMWatts
1338193
1244219
1146239
1046254
942262
370 CFM/ton
CFMWatts
1408222
1317249
1223270
1126285
1025294
390 CFM/ton
CFMWatts
1481255
1393282
1301304
1206320
1108329
410 CFM/ton
CFMWatts
1555291
1468319
1379341
1286357
1189367
NOTES: 1. * Models start with "A" or "T" 2. † Factory Setting 3. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 4. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
PerformanceData
TAM7A0C36 AIRFLOW PERFORMANCE TABLE - CONSTANT TORQUE MODE
TAM7A0C36 MINIMUM HEATER CFM TABLE
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA
*AM7A0C36H31SAA 876/979 876/1236 927/1236 824/979 927/1288 1030/1339 1236/1442
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.

Pub. No. 22-1847-02 13
TAM7A0C42 AIRFLOW PERFORMANCE TABLE - CONSTANT CFM
PerformanceData
TAM7A0C42 MINIMUM HEATER CFM TABLE
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA
*AM7A0C42H31SAA 978/1093 978/1380 1035/1380 920/1093 1035/1438 1150/1495 1380/1610
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
AIRFLOW PERFORMANCE - CONSTANT CFM*AM7A0C42 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE HEATING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9
2.5 tons
330 CFM/ton
CFMWatts
85368
832108
820149
815191
813232
360 CFM/ton
CFMWatts
91282
897125
893170
895217
901264
350 CFM/ton
CFMWatts
89676
880119
870162
867162
866250
380 CFM/ton
CFMWatts
95692
945137
943185
946234
951283
370 CFM/ton
CFMWatts
93985
926130
920176
918222
918268
400 CFM/ton
CFMWatts
1000102
992151
992201
997253
1002304
390 CFM/ton
CFMWatts
98395
973143
969191
968240
969288
420 CFM/ton
CFMWatts
1044114
1040166
1042219
1047273
1052325
3 tons
330 CFM/ton
CFMWatts
99699
987147
984196
984246
983294
360 CFM/ton
CFMWatts
1071122
1069175
1072230
1078285
1082339
350 CFM/ton
CFMWatts
1049112
1043164
1044217
1045269
1045320
380 CFM/ton
CFMWatts
1126138
1127195
1132254
1139312
1142368
370CFM/ton
CFMWatts
1101127
1100183
1103239
1106294
1107348
400 CFM/ton
CFMWatts
1181157
1186218
1193280
1200341
1201399
390 CFM/ton
CFMWatts
1156144
1159203
1164264
1167322
1168379
420 CFM/ton
CFMWatts
1239177
1247243
1256309
1261373
1259432
3.5 tons †
330 CFM/ton
CFMWatts
1142140
1143198
1148257
1152315
1152370
360 CFM/ton
CFMWatts
1239177
1247243
1256309
1261373
1259432
350 CFM/ton
CFMWatts
1208162
1212224
1220288
1224350
1222407
380 CFM/ton
CFMWatts
1308205
1319276
1329346
1331412
1323470
370 † CFM/ton
CFMWatts
1274187
1283254
1293323
1295387
1289445
400 CFM/ton
CFMWatts
1381237
1394313
1401386
1398452
1332475
390 CFM/ton
CFMWatts
1344215
1357289
1366361
1364427
1345479
420 CFM/ton
CFMWatts
1456275
1468355
1471429
1443481
1323470
4 tons
330 CFM/ton
CFMWatts
1299196
1309266
1318336
1321401
1313459
360 CFM/ton
CFMWatts
1423258
1436337
1441410
1434475
1326472
350 CFM/ton
CFMWatts
1380232
1394307
1401381
1398447
1339477
380 CFM/ton
CFMWatts
1511304
1520386
1517459
1436477
1317466
370 CFM/ton
CFMWatts
1466273
1479354
1481428
1451482
1327470
400 CFM/ton
CFMWatts
1598356
1599437
1536472
1426470
1308461
390 CFM/ton
CFMWatts
1553320
1561403
1544470
1438475
1315465
420 CFM/ton
CFMWatts
1679409
1620451
1534471
1417464
1301456
NOTES: 1. * Models start with "A" or "T" 2. † Factory Setting 3. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 4. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.

14 Pub. No. 22-1847-02
AIRFLOW PERFORMANCE - CONSTANT TORQUE MODE (See Switch S2-5)*AM7A0C42 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9
2.5 tons
330 CFM/ton
CFMWatts
98896
861114
712125
523128
208143
350 CFM/ton
CFMWatts
1030107
909126
768137
597141
353144
370 CFM/ton
CFMWatts
1072118
956139
823151
665155
458155
390 CFM/ton
CFMWatts
1115131
1003152
877165
729170
546169
3 tons
330 CFM/ton
CFMWatts
1128135
1017156
892170
748175
570174
350 CFM/ton
CFMWatts
1180152
1074174
956189
821196
662194
370CFM/ton
CFMWatts
1233171
1132195
1019210
893218
747217
390 CFM/ton
CFMWatts
1288192
1190217
1083234
964242
828242
3.5 tons †
330 CFM/ton
CFMWatts
1274187
1175211
1067228
946236
808236
350 CFM/ton
CFMWatts
1340214
1245239
1142257
1028267
901268
370 † CFM/ton
CFMWatts
1408245
1317272
1218291
1110301
991303
390 CFM/ton
CFMWatts
1479280
1390308
1295328
1192340
1080343
4 tons
330 CFM/ton
CFMWatts
1457268
1368296
1272316
1167327
1053330
350 CFM/ton
CFMWatts
1538312
1452340
1360361
1260374
1153378
370 CFM/ton
CFMWatts
1618359
1534389
1445411
1350425
1248429
390 CFM/ton
CFMWatts
1693409
1611439
1525462
1432476
1333481
NOTES: 1. * Models start with "A" or "T" 2. † Factory Setting 3. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 4. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
PerformanceData
TAM7A0C42 AIRFLOW PERFORMANCE TABLE - CONSTANT TORQUE MODE
TAM7A0C42 MINIMUM HEATER CFM TABLE
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA
*AM7A0C42H31SAA 978/1093 978/1380 1035/1380 920/1093 1035/1438 1150/1495 1380/1610
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.

Pub. No. 22-1847-02 15
PerformanceData
TAM7A0C48 AIRFLOW PERFORMANCE TABLE - CONSTANT CFM
TAM7A0C48 MINIMUM HEATER CFM TABLE
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA BAYEVCC25BK1AA
*AM7A0C48H41SAA 1063/1188 1063/1500 1125/1500 1000/1188 1125/1563 1250/1625 1500/1750 1625/1813WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
AIRFLOW PERFORMANCE - CONSTANT CFM*AM7A0C48 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE HEATING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9
3 tons
330 CFM/ton
CFMWatts
110192
1017143
1015190
1006232
994270
380 CFM/ton
CFMWatts
1150128
1155184
1154237
1150286
1141330
350 CFM/ton
CFMWatts
1067106
1073158
1072208
1065252
1053292
400 CFM/ton
CFMWatts
1204145
1210203
1210259
1207310
1199356
370 CFM/ton
CFMWatts
1122120
1129175
1128227
1122274
1112315
420 CFM/ton
CFMWatts
1259162
1266224
1267282
1264335
1258384
390 CFM/ton
CFMWatts
1177136
1185194
1185248
1180297
1170341
440 CFM/ton
CFMWatts
1314182
1322246
1324307
1322363
1316413
3.5 tons
330 CFM/ton
CFMWatts
1164132
1171189
1171242
1165291
1156334
380 CFM/ton
CFMWatts
1323185
1331250
1333250
1331368
1325418
350 CFM/ton
CFMWatts
1228152
1235212
1236268
1232319
1224365
400 CFM/ton
CFMWatts
1388211
1398279
1400343
1399403
1395457
370 CFM/ton
CFMWatts
1292174
1300237
1302296
1299350
1292399
420 CFM/ton
CFMWatts
1455240
1465312
1468379
1469441
1463497
390 CFM/ton
CFMWatts
1356198
1366265
1369327
1367384
1361435
440 CFM/ton
CFMWatts
1523272
1534347
1538418
1538483
1534542
4 tons †
330 CFM/ton
CFMWatts
1315212
1324247
1326307
1323362
1316412
380 CFM/ton
CFMWatts
1502262
1514337
1518406
1518471
1514529
350 † CFM/ton
CFMWatts
1389212
1399280
1403343
1401402
1395455
400 CFM/ton
CFMWatts
1582302
1594382
1598454
1598522
1591581
370 CFM/ton
CFMWatts
1465245
1476317
1481384
1480446
1475502
420 CFM/ton
CFMWatts
1664348
1675421
1680508
1678577
1669638
390 CFM/ton
CFMWatts
1543283
1555359
1560430
1560495
1554553
440 CFM/ton
CFMWatts
1748400
1758486
1760565
1755634
1708668
4.5 tons **
330 CFM/ton
CFMWatts
1470247
1481319
1486387
1485449
1480505
380 CFM/ton
CFMWatts
1695367
1706451
1710528
1707598
1697659
350 CFM/ton
CFMWatts
1558290
1570367
1575439
1575505
1568563
400 CFM/ton
CFMWatts
1790428
1799515
1799594
1792664
1700661
370 CFM/ton
CFMWatts
1649340
1661422
1666497
1664565
1655625
420 CFM/ton
CFMWatts
1885496
1889584
1884662
1783656
1683648
390 CFM/ton
CFMWatts
1742397
1754483
1756561
1751630
1708666
440 CFM/ton
CFMWatts
1976568
1973655
1871652
1765643
1667636
NOTES: 1. * Models start with "A" or "T" 2. ** Not an actual OD size 3. † Factory Setting 4. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 5. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.

16 Pub. No. 22-1847-02
AIRFLOW PERFORMANCE - CONSTANT TORQUE MODE (See Switch S2-5)*AM7A0C48 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9
3 tons
330 CFM/ton
CFMWatts
1127117
1020143
907163
786173
654174
350 CFM/ton
CFMWatts
1180132
1078160
972180
859192
738194
370 CFM/ton
CFMWatts
1233149
1136177
1035199
929212
816215
390 CFM/ton
CFMWatts
1287167
1194196
1097219
996233
890238
3.5 tons
330 CFM/ton
CFMWatts
1274162
1179191
1082214
980227
872232
350 CFM/ton
CFMWatts
1336185
1246215
1153238
1056253
955259
370 CFM/ton
CFMWatts
1400210
1313241
1224265
1132281
1036288
390 CFM/ton
CFMWatts
1465238
1381270
1295295
1207312
1115320
4 tons †
330 CFM/ton
CFMWatts
1443228
1358260
1271284
1181301
1088308
350 †CFM/ton
CFMWatts
1517262
1436295
1352321
1266338
1177346
370 CFM/ton
CFMWatts
1594301
1516335
1435361
1352379
1267388
390 CFM/ton
CFMWatts
1673346
1597380
1519406
1439425
1356434
4.5 tons **
330 CFM/ton
CFMWatts
1599304
1521337
1440364
1357382
1272391
350 CFM/ton
CFMWatts
1688354
1613389
1535415
1455434
1373444
370 CFM/ton
CFMWatts
1780412
1707447
1632474
1554493
1475503
390 CFM/ton
CFMWatts
1873477
1801512
1728539
1653558
1576567
NOTES: 1. * Models start with "A" or "T" 2. ** Not an actual OD size 3. † Factory Setting 4. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 5. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
PerformanceData
TAM7A0C48 AIRFLOW PERFORMANCE TABLE - CONSTANT TORQUE MODE
TAM7A0C48 MINIMUM HEATER CFM TABLE
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA BAYEVCC25BK1AA
*AM7A0C48H41SAA 1063/1188 1063/1500 1125/1500 1000/1188 1125/1563 1250/1625 1500/1750 1625/1813WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.

Pub. No. 22-1847-02 17
TAM7A0C60 AIRFLOW PERFORMANCE TABLE - CONSTANT CFM
PerformanceData
TAM7A0C60 MINIMUM HEATER CFM TABLE
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA BAYEVCC25BK1AA
*AM7A0C60H51SAA 1063/1188 1063/1500 1125/1500 1000/1188 1125/1563 1250/1625 1500/1750 1625/1813WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
AIRFLOW PERFORMANCE - CONSTANT CFM*AM7A0C60 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE HEATING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9
3.5 tons
370 CFM/ton
CFMWatts
1316194
1328258
1328314
1320364
1308406
400 CFM/ton
CFMWatts
1404205
1424275
1426337
1419391
1410440
380 CFM/ton
CFMWatts
1349207
1360272
1359329
1352380
1338422
410 CFM/ton
CFMWatts
1437218
1455289
1457351
1451407
1441456
390 CFM/ton
CFMWatts
1381220
1391286
1390344
1383396
1370439
420 CFM/ton
CFMWatts
1467230
1487303
1489367
1482423
1474474
400 CFM/ton
CFMWatts
1413234
1422300
1421360
1415412
1402456
430 CFM/ton
CFMWatts
1500244
1516317
1519382
1515441
1505491
4 tons
370 CFM/ton
CFMWatts
1485269
1493337
1493398
1486452
1475498
400 CFM/ton
CFMWatts
1586285
1600360
1604428
1601490
1592543
380 CFM/ton
CFMWatts
1521287
1529356
1528418
1522474
1511520
410 CFM/ton
CFMWatts
1622303
1636379
1640449
1638512
1629566
390 CFM/ton
CFMWatts
1557306
1564376
1564440
1559496
1548544
420 CFM/ton
CFMWatts
1659322
1672399
1677471
1675535
1667591
400 CFM/ton
CFMWatts
1593326
1600397
1600462
1595519
1585568
430 CFM/ton
CFMWatts
1695342
1708421
1713493
1712559
1705616
4.5 tons**†
370 †CFM/ton
CFMWatts
1652360
1659433
1660500
1655559
1646610
400 CFM/ton
CFMWatts
1769385
1782467
1789543
1788611
1783671
380 CFM/ton
CFMWatts
1694386
1701460
1701528
1697589
1688641
410 CFM/ton
CFMWatts
1811411
1826495
1831572
1832643
1827704
390 CFM/ton
CFMWatts
1736413
1742489
1744558
1740620
1732673
420 CFM/ton
CFMWatts
1854439
1869525
1875604
1877676
1872739
400 CFM/ton
CFMWatts
1778442
1785519
1786590
1783653
1776707
430 CFM/ton
CFMWatts
1898468
1913556
1919637
1921711
1918777
5 tons
370 CFM/ton
CFMWatts
1826475
1833555
1835627
1832692
1826748
400 CFM/ton
CFMWatts
1963515
1978606
1985689
1988766
1985833
380 CFM/ton
CFMWatts
1875512
1882593
1884667
1882733
1876791
410 CFM/ton
CFMWatts
2014554
2029647
2037733
2040811
2038880
390 CFM/ton
CFMWatts
1924551
1932634
1935710
1933777
1927836
420 CFM/ton
CFMWatts
2066595
2082691
2090779
2093859
2090928
400 CFM/ton
CFMWatts
1975593
1983678
1986755
1985824
1979884
430 CFM/ton
CFMWatts
2120640
2136738
2143828
2147909
2143980
NOTES: 1. * Models start with "A" or "T" 2. ** Not an actual OD size 3. † Factory Setting 4. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 5. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.

18 Pub. No. 22-1847-02
AIRFLOW PERFORMANCE - CONSTANT TORQUE MODE (See Switch S2-5)*AM7A0C60 WITH WET COIL, NO FILTER
OUTDOORMULTIPLIER
(TONS)
COOLING AIRFLOWSETTING
AirflowPower
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9
3.5 tons
370 CFM/ton
CFMWatts
1404201
1330234
1244260
1146276
1033280
380 CFM/ton
CFMWatts
1435213
1362247
1278273
1183290
1074295
390 CFM/ton
CFMWatts
1466225
1394260
1312287
1220304
1115310
400 CFM/ton
CFMWatts
1496238
1426273
1346301
1256319
1154325
4 tons
370 CFM/ton
CFMWatts
1583278
1516314
1441342
1357362
1263370
380 CFM/ton
CFMWatts
1618295
1552331
1479360
1396380
1305389
390 CFM/ton
CFMWatts
1654313
1589350
1516379
1436400
1347409
400 CFM/ton
CFMWatts
1689332
1625369
1554399
1475420
1389430
4.5 tons**†
370 †CFM/ton
CFMWatts
1748365
1685403
1616433
1540454
1456465
380 CFM/ton
CFMWatts
1789390
1727427
1659458
1584480
1503491
390 CFM/ton
CFMWatts
1831416
1770454
1703484
1629506
1549518
400 CFM/ton
CFMWatts
1873443
1813481
1747512
1675534
1597546
5 tons
370 CFM/ton
CFMWatts
1921476
1862515
1797545
1726568
1650580
380 CFM/ton
CFMWatts
1971512
1912550
1848581
1778603
1703616
390 CFM/ton
CFMWatts
2021550
1963588
1900619
1832641
1758654
400 CFM/ton
CFMWatts
2073590
2015629
1953660
1886682
1814695
NOTES: 1. * Models start with "A" or "T" 2. ** Not an actual OD size 3. † Factory Setting 4. At continuous fan setting: Airflow values are approximately 50% of the listed cooling values 5. Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
PerformanceData
TAM7A0C60 AIRFLOW PERFORMANCE TABLE - CONSTANT TORQUE MODE
TAM7A0C60 MINIMUM HEATER CFM TABLE
MODEL NO.BAYEVAC05BK1AABAYEVAC05LG1AA
BAYEVAC08BK1AABAYEVAC08LG1AA
BAYEVAC10BK1AABAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVBC15BK1AA BAYEVCB15LG3AA BAYEVBC20BK1AA BAYEVCC25BK1AA
*AM7A0C60H51SAA 1063/1188 1063/1500 1125/1500 1000/1188 1125/1563 1250/1625 1500/1750 1625/1813WITHOUT HEAT PUMP / WITH HPSEE AIR HANDLER NAMEPLATE
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX
NOTE: Minimum auxiliary heating airflow is automatically configured by the air handler model and the auxiliary heater model number. This is not field adjustable.

Pub. No. 22-1847-02 19
ElectricalData
Notes:
1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters
2. Heater model numbers may have additional suffix digits.
kW BTUH kW BTUH
No Heater 0 - - 3.0** 4 15 - - 3.0** 4 15BAYEVAC05++1 1 4.80 16400 20.0 29 30 3.60 12300 17.3 25 25BAYEVAC08++1 1 7.68 26200 32.0 44 45 5.76 19700 27.7 38 40BAYEVAC10++1 1 9.60 32800 40.0 54 60 7.20 24600 34.6 47 50BAYEVAC10LG3 1-3 PH 9.60 32800 23.1 32 35 7.20 24600 20.0 28 30
*AM7A0A24H21SA
Note: * May be "A" or "T" Note: ** Motor Amps
208 Volt
Capacity Heater Amps per
Circuit
MinimumCircuit
Ampacity
MaximumOverload
Protection
Heater Model No. Capacity Minimum Circuit
Ampacity
MaximumOverload
Protection
240 Volt
HeaterAmps per
Circuit
No. of Circuits
Heater Attribute Data
kW BTUH kW BTUH
No Heater 0 - - 3.0** 4 15 - - 3.0** 4 15BAYEVAC05++1 1 4.80 16400 20.0 29 30 3.60 12300 17.3 25 25BAYEVAC08++1 1 7.68 26200 32.0 44 45 5.76 19700 27.7 38 40BAYEVAC10++1 1 9.60 32800 40.0 54 60 7.20 24600 34.6 47 50BAYEVAC10LG3 1-3 PH 9.60 32800 23.1 32 35 7.20 24600 20.0 28 30BAYEVBC15LG3 1-3 PH 14.40 42000 34.6 47 50 10.80 36900 30.0 41 45
9.60 32800 40.0 54 60 7.20 24600 34.6 47 504.80 16400 20.0 25 25 3.60 12300 17.3 22 25
208 Volt
Capacity Heater Amps per
Circuit
MinimumCircuit
Ampacity
MaximumOverload
Protection
Capacity
Note: * May be "A" or "T" Note: ** Motor Amps1 MCA and MOP for circuit 1 contains the motor amps
HeaterAmps per
Circuit
Heater Attribute Data
BAYEVBC15BK1 - Circuit 1 1BAYEVBC15BK1 - Circuit 2
MinimumCircuit
Ampacity
MaximumOverload
Protection
*AM7A0B30H21SA
Heater Model No. No. of Circuits
240 Volt
2

20 Pub. No. 22-1847-02
ElectricalData
kW BTUH kW BTUH
No Heater 0 - - 3.0** 4 15 - - 3.0** 4 15BAYEVAC05++1 1 4.80 16400 20.0 29 30 3.60 12300 17.3 25 25BAYEVAC08++1 1 7.68 26200 32.0 44 45 5.76 19700 27.7 38 40BAYEVAC10++1 1 9.60 32800 40.0 54 60 7.20 24600 34.6 47 50BAYEVAC10LG3 1-3 PH 9.60 32800 23.1 32 35 7.20 24600 20.0 28 30BAYEVBC15LG3 1-3 PH 14.40 42000 34.6 47 50 10.80 36900 30.0 41 45
9.60 32800 40.0 54 60 7.20 24600 34.6 47 50
4.80 16400 20.0 25 25 3.60 12300 17.3 22 25
9.60 32800 40.0 54 60 7.20 24600 34.6 47 50
9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 Note: * May be "A" or "T" Note: ** Motor Amps1 MCA and MOP for circuit 1 contains the motor amps
BAYEVBC15BK1 - Circuit 1 1BAYEVBC15BK1 - Circuit 2
BAYEVBC20BK1 - Circuit 1 1BAYEVBC20BK1 - Circuit 2
HeaterAmps per
Circuit
MinimumCircuit
Ampacity
MaximumOverload
Protection
MaximumOverload
Protection
Capacity Heater Amps per
Circuit
Heater Attribute Data
MinimumCircuit
Ampacity
2
2
*AM7A0C36H31SA
Heater Model No. No. of Circuits
240 Volt 208 Volt
Capacity
kW BTUH kW BTUH
No Heater 0 - - 3.0** 4 15 - - 3.0** 4 15BAYEVAC05++1 1 4.80 16400 20.0 29 30 3.60 12300 17.3 25 25BAYEVAC08++1 1 7.68 26200 32.0 44 45 5.76 19700 27.7 38 40BAYEVAC10++1 1 9.60 32800 40.0 54 60 7.20 24600 34.6 47 50BAYEVAC10LG3 1-3 PH 9.60 32800 23.1 32 35 7.20 24600 20.0 28 30BAYEVBC15LG3 1-3 PH 14.40 42000 34.6 47 50 10.80 36900 30.0 41 45
9.60 32800 40.0 54 60 7.20 24600 34.6 47 50
4.80 16400 20.0 25 25 3.60 12300 17.3 22 25
9.60 32800 40.0 54 60 7.20 24600 34.6 47 50
9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 Note: * May be "A" or "T" Note: ** Motor Amps1 MCA and MOP for circuit 1 contains the motor amps
Heater Attribute Data*AM7A0C42H31SA
Heater Model No. No. of Circuits
240 Volt 208 Volt
Capacity Heater Amps per
Circuit
MinimumCircuit
Ampacity
MaximumOverload
Protection
Capacity Heater Amps per
Circuit
MinimumCircuit
Ampacity
MaximumOverload
Protection
BAYEVBC15BK1 - Circuit 1 1BAYEVBC15BK1 - Circuit 2
BAYEVBC20BK1 - Circuit 1 1BAYEVBC20BK1 - Circuit 2 2
2
Notes:
1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters
2. Heater model numbers may have additional suffix digits.

Pub. No. 22-1847-02 21
ElectricalData
kW BTUH kW BTUH
No Heater 0 - - 4.2** 5 15 - - 4.2** 5 15BAYEVAC05++1 1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30BAYEVAC08++1 1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40BAYEVAC10++1 1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50BAYEVAC10LG3 1-3 PH 9.60 32800 23.1 34 35 7.20 24600 20.0 30 30BAYEVBC15LG3 1-3 PH 14.40 42000 34.6 48 50 10.80 36900 30.0 42 45
9.60 32800 40.0 55 60 7.20 24600 34.6 49 50
4.80 16400 20.0 25 25 3.60 12300 17.3 22 25
9.60 32800 40.0 55 60 7.20 24600 34.6 49 50
9.60 32800 40.0 50 50 7.20 24600 34.6 43 45
9.60 32800 40.0 55 60 7.20 24600 34.6 49 50
9.60 32800 40.0 50 50 7.20 24600 34.6 43 45
4.80 16400 20.0 25 25 3.60 12300 17.3 22 25
BAYEVCC25BK1 - Circuit 1 1BAYEVCC25BK1 - Circuit 2BAYEVCC25BK1 - Circuit 3
Note: * May be "A" or "T" Note: ** Motor Amps1 MCA and MOP for circuit 1 contains the motor amps
Heater Attribute Data*AM7A0C48H41SA
MinimumCircuit
Ampacity
MaximumOverload
Protection
Capacity Heater Amps per
Circuit
MinimumCircuit
Ampacity
MaximumOverload
Protection
BAYEVBC15BK1 - Circuit 1 1BAYEVBC15BK1 - Circuit 2
BAYEVBC20BK1 - Circuit 1 1BAYEVBC20BK1 - Circuit 2
Heater Model No. No. of Circuits
240 Volt 208 Volt
Capacity Heater Amps per
Circuit
2
2
3
Notes:
1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters
2. Heater model numbers may have additional suffix digits.

22 Pub. No. 22-1847-02
ElectricalData
kW BTUH kW BTUH
No Heater 0 - - 5.5** 7 15 - - 5.5** 7 15BAYEVAC05++1 1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30BAYEVAC08++1 1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40BAYEVAC10++1 1 9.60 32800 40.0 55 60 7.20 24600 34.6 49 50BAYEVAC10LG3 1-3 PH 9.60 32800 23.1 34 35 7.20 24600 20.0 30 30BAYEVBC15LG3 1-3 PH 14.40 42000 34.6 48 50 10.80 36900 30.0 42 45
9.60 32800 40.0 55 60 7.20 24600 34.6 49 50
4.80 16400 20.0 25 25 3.60 12300 17.3 22 25
9.60 32800 40.0 55 60 7.20 24600 34.6 49 50
9.60 32800 40.0 50 50 7.20 24600 34.6 43 45
9.60 32800 40.0 55 60 7.20 24600 34.6 49 50
9.60 32800 40.0 50 50 7.20 24600 34.6 43 45
4.80 16400 20.0 25 25 3.60 12300 17.3 22 25
BAYEVCC25BK1 - Circuit 1 1BAYEVCC25BK1 - Circuit 2BAYEVCC25BK1 - Circuit 3
Note: * May be "A" or "T" Note: ** Motor Amps1 MCA and MOP for circuit 1 contains the motor amps
MinimumCircuit
Ampacity
MaximumOverload
Protection
BAYEVBC15BK1 - Circuit 1 1BAYEVBC15BK1 - Circuit 2
BAYEVBC20BK1 - Circuit 1 1BAYEVBC20BK1 - Circuit 2
Heater Model No. No. of Circuits
240 Volt 208 Volt
Capacity Heater Amps per
Circuit
Heater Attribute Data*AM7A0C60H51SA
Capacity Heater Amps per
Circuit
MinimumCircuit
Ampacity
MaximumOverload
Protection
2
3
2
Notes:
1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters
2. Heater model numbers may have additional suffix digits.

Pub. No. 22-1847-02 23
AIR HANDLER ELECTRIC HEATER PRESSURE DROP
Air handler electric heater pressure drop is negligible for the heaters and is included in the airflow data for the Series 7 air handlers.
ElectricalData

24 Pub. No. 22-1847-02
TAM7 AIR HANDLER AND HEATER MATRIX - ALLOWBLE COMBINATIONS
ElectricalData
AIR HANDLER
MODEL NUMBER
AC05BK1AA4.80 Kw
BK
AC05LG1AA4.80 Kw
LG
AC08BK1AA7.68 Kw
BK
AC08LG1AA7.68 Kw
LG
AC10BK1AA9.60 Kw
BK
AC10LG1AA9.60 Kw
LG
BC15BK1AA14.40 Kw
BK
BC20BK1AA19.20 Kw
BK
CC25BK1AA24.00 Kw
BK*AM7A0A24H21SA Y Y Y Y Y Y ‐ ‐ ‐*AM7A0B30H21SA Y Y Y Y Y Y Y - ‐*AM7A0C36H31SA Y Y Y Y Y Y Y Y -*AM7A0C42H31SA Y Y Y Y Y Y Y Y -*AM7A0C48H41SA Y Y Y Y Y Y Y Y Y*AM7A0C60H51SA Y Y Y Y Y Y Y Y Y
APPROVED AIR HANDLER ‐ HEATER COMBINATIONSHEATER MODEL NUMBER BAYEV‐
AIR HANDLER
MODEL NUMBER
AC10LG3AA9.60 Kw
LG
BC15LG3AA14.4 Kw
LG*AM7A0A24H21SA Y ‐*AM7A0B30H21SA Y Y*AM7A0C36H31SA Y Y*AM7A0C42H31SA Y Y*AM7A0C48H41SA Y Y*AM7A0C60H51SA Y Y
APPROVED AIR HANDLER ‐ HEATER COMBINATIONS
HEATER MODEL NUMBER BAYEV‐

Pub. No. 22-1847-02 25
ElectricalData
WIR
ING
DIA
GR
AM
FO
R T
AM
7 A
IR H
AN
DL
ER
S
No
te:
ET
sen
sor
wiri
ng m
ay b
e br
own

26 Pub. No. 22-1847-02
FieldWiring
Comfort Control
Air Handler
Air Conditioner
Neatly bundle all low voltage wires behind the service valve cover as shown.
Field wiring
Yellow
Blue
Red
Yellow
Green
White
Blue
B
B - Blue
WGY1
Y2
Y1 - Yellow
RO
ORB
YI
W1
YO
Y2
BKG
W2W3 *
(In)
(Out)
• * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat. • YI and YO connections must be made as shown for freeze protection and internally mounted condensate overflow circuits to work properly. • Internally mounted condensate switch is optional and must be ordered separately. • If 3rd party condensate overflow switches are installed, they should be wired in series between YO and Y to the outdoor unit.
Single Stage Cooling

Pub. No. 22-1847-02 27
FieldWiring
• * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat • YI and YO connections must be made as shown for freeze protection and internally mounted condensate overflow circuits
to work properly • Internally mounted condensate switch is optional and must be ordered separately • If a 3rd party condensate overflow switch is installed, it should be wired in series between YO and Y to the outdoor unit
Single Stage HP
Comfort Control
Air Handler
Heat Pump
Neatly bundle all low voltage wires behind the service valve cover as shown.
Field wiring
YellowBlue
Black(X2)
Red
Orange
Red
YellowOrange
Green
White
Blue
B
B - Blue
WX2
GY1
Y1 - Yellow
RO
ORB
YIY2
W1
YO
BKG
W2W3 *
R - RedO - Orange
(In)
(Out)
W1 - White

28 Pub. No. 22-1847-02
Two Stage Cooling
• * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat. • YI and YO connections must be made as shown for freeze protection and internally mounted condensate overflow circuits to work properly. • Internally mounted condensate switch is optional and must be ordered separately. • If 3rd party condensate overflow switches are installed, they should be wired in series between YO and Y to the outdoor unit.
Comfort Control
Air Handler
Air Conditioner
Neatly bundle all low voltage wires behind the service valve cover as shown.
Yellow/Red
Field wiring
Yellow/Black
Blue
Red
YellowGreenWhite
BlueB
B - Blue
WGY1
BrownY2
Y1 - Yellow
Y2 - BrownRO
ORB
YI
W1
YO
Y2
BKG
W2W3 *
(In)
(Out)
FieldWiring

Pub. No. 22-1847-02 29
• * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat • YI and YO connections must be made as shown for freeze protection and internally mounted condensate overflow circuits
to work properly • Internally mounted condensate switch is optional and must be ordered separately • If a 3rd party condensate overflow switch is installed, it should be wired in series between YO and Y to the outdoor unit
Comfort Control
Air Handler
Heat Pump
Neatly bundle all low voltage wires behind the service valve cover as shown.
Yellow/Red
Field wiring
Yellow
Blue
Black(X2)
RedOrange
Red
YellowOrange
GreenWhite
BlueB
B - Blue
WX2
GY1
BrownY2
Y1 - Yellow
Y2 - BrownRO
ORB
YI
W1
YO
Y2
BKG
W2W3 *
R - RedO - Orange
(In)
(Out)
W1 - White
Two Stage HP
FieldWiring

30 Pub. No. 22-1847-02
TAM7Convertibility
Multi-position Air Handler
Airflo
w
AirflowAirflow
Air
flo
w
Upflow Condensate Drains
Refrigerant Connections
Downflow Condensate Drains
Refrigerant Connections
Vertical Downflow*(as shipped)
Horizontal Left*
Vertical Upflow*
Horizontal Right*
Horizontal Left Condensate Drains
Refrigerant Connections
Horizontal Right Condensate Drains
Refrigerant Connections
* Note: No internal modifications required for any position.1 Badge rotation will keep brand in correct position
1
1
1
1

Pub. No. 22-1847-02 31
Dimensions
TAM7 AIR HANDLER DIMENSIONAL DATA
Model No. H W
TAM7A0A24 49.9 17.5
TAM7A0B30 55.7 21.3
TAM7A0C36 56.9 23.5
TAM7A0C42 56.9 23.5
TAM7A0C48 61.7 23.5
TAM7A0C60 61.7 23.5
TAM7 AIR HANDLERS ARE ALL TWO PIECE CABINETS.
21.75”
H
W

32 Pub. No. 22-1847-02
TAM7 OUTLINE DRAWING
MODEL NO. A B C D E F H FLOWCONTROL
GAS LINE BRAZE
LIQ LINE BRAZE
*AM7A0A24H21SA 49.9 17.5 14.5 39.6 14.5 7.3 24.4 EEV 3/4 3/8
*AM7A0B30H21SA 55.7 21.3 18.4 45.5 18.4 9.2 24.8 EEV 3/4 3/8
*AM7A0C36H31SA 56.9 23.5 20.5 46.7 20.5 10.3 24.2 EEV 7/8 3/8
*AM7A0C42H31SA 56.9 23.5 20.5 46.7 20.5 10.3 24.5 EEV 7/8 3/8
*AM7A0C48H41SA 61.7 23.5 20.5 51.5 20.5 10.3 24.9 EEV 7/8 3/8
*AM7A0C60H51SA 61.7 23.5 20.5 51.5 20.5 10.3 24.9 EEV 7/8 3/8
* May be “A” or “T”