Training - Flowserve Apm Pump Cw Pump Part3

4
Centrifugal Pump Basics  Af fi ni ty Law s •System conditions may dictate that the pump operate at a speed other than the current operating speed of the pump. •A new performance may be obtained by changing speed or impeller diameter. •The affi nit laws ma be used to redi ct the erfo rmance at anot her Flowserve Corporation Property and Confidential speed or another impeller diameter. 63  Affinity Law s - Capac it y Chang es Ce ntr ifug al Pump Basics Due t o di amet er changes Due to speed changes Flowserve Corporation Property and Confidential  64 Where Q = capacity, n = speed, d = d iameter Rev-0 CIRCULATING WATER PUMP - O & M TRAINING 32 of 97

Transcript of Training - Flowserve Apm Pump Cw Pump Part3

Page 1: Training - Flowserve Apm Pump Cw Pump Part3

7/26/2019 Training - Flowserve Apm Pump Cw Pump Part3

http://slidepdf.com/reader/full/training-flowserve-apm-pump-cw-pump-part3 1/4

Centrifugal Pump Basics

 Affini ty Laws

•System conditions may dictate that the pump operate at a speed other

than the current operating speed of the pump.

•A new performance may be obtained by changing speed or impeller

diameter.

•The affinit laws ma be used to redict the erformance at another

Flowserve Corporation Property and Confidential

speed or another impeller diameter.

63

 Affini ty Laws - Capacity Changes

Centrifugal Pump Basics

Due to diameter changes Due to speed changes

Flowserve Corporation Property and Confidential  64

Where Q = capacity, n = speed, d = d iameter 

Rev-0 CIRCULATING WATER PUMP - O & M TRAINING 32 of 97

Page 2: Training - Flowserve Apm Pump Cw Pump Part3

7/26/2019 Training - Flowserve Apm Pump Cw Pump Part3

http://slidepdf.com/reader/full/training-flowserve-apm-pump-cw-pump-part3 2/4

 Affini ty Laws - Head Changes

Centrifugal Pump Basics

Due to diameter changes Due to speed changes

Flowserve Corporation Property and Confidential  65

Where H = head , n = speed, d = diameter 

 Affini ty Laws - Power Changes

Centrifugal Pump Basics

Due to diameter changes Due to speed changes

Flowserve Corporation Property and Confidential  66

Where BHP = horsepower , n = speed, d = diameter 

Rev-0 CIRCULATING WATER PUMP - O & M TRAINING 33 of 97

Page 3: Training - Flowserve Apm Pump Cw Pump Part3

7/26/2019 Training - Flowserve Apm Pump Cw Pump Part3

http://slidepdf.com/reader/full/training-flowserve-apm-pump-cw-pump-part3 3/4

 Affini ty Laws

Centrifugal Pump Basics

Flowserve Corporation Property and Confidential  67

Exercise

Centrifugal Pump Basics

Bryce has a pump that he uses for beer production. He would like to

make more beer and found a larger impeller in the warehouse for his

pump that has a 10” diameter.What would the new flow, head, and HP be?

Current conditions:

Flowserve Corporation Property and Confidential

flow 1500 gpm

head 50 feet

motor 30 hp

impeller diameter 8.75”

68

Rev-0 CIRCULATING WATER PUMP - O & M TRAINING 34 of 97

Page 4: Training - Flowserve Apm Pump Cw Pump Part3

7/26/2019 Training - Flowserve Apm Pump Cw Pump Part3

http://slidepdf.com/reader/full/training-flowserve-apm-pump-cw-pump-part3 4/4

Brake Horsepower 

Centrifugal Pump Basics

The input horsepower required at the pump shaft for a given capacity,

head, and specific gravity at the speed shown on the performance

curve

Flowserve Corporation Property and Confidential  69

Centrifugal Pump Basics

Brake Horsepower Exercise

Using the below graph, determine the BHP using the equation for the

following conditions.

•Head = 60 feet.

•Flow = 400 GPM.

•Efficiency = 70% (use 0.70)

Flowserve Corporation Property and Confidential

•Specific Gravity = 1

70

Rev-0 CIRCULATING WATER PUMP - O & M TRAINING 35 of 97