No Were job specifications sent to G.A.L.?
Building Voltage:
Are there any jobs specifications? Yes Yes No
VAC 3Ph/60Hz Single Phase AC
Rear openings:
GENERAL INFORMATION
Car name: (1st car installed )
Car speed (FPM):
Car capacity (Lbs):
S=Simplex / G=Group:
Number of floors:
Front openings:
65 71 2 83 4
ELEVATOR SAFETY CODE COMPLIANCE
Code Edition: ASME A17.1 / B44
ASME A17.1
2016
1996
2013
1993
2010
NYC
2007 2004
Other:
MACHINE AND BRAKE
Machine: New Reuse existing Brand: Model: Hollister-Whitney job No.:
Machine type: GearlessGeared
Machine location: Overhead Basement
Motor type: DCAC
MRL Roping: 1:1 2:1
Em brake: Ind. 2nd brake on machine
Main brake: Pick volt:
HOIST MOTOR
Wire run distance between
Motor data AC 6
Horse power:
Full load volts:
Full load amps:
RPM:
Acceleration volts:
Rated frequency (Hz):
Acceleration amps:
51 7 82 3 4
Motor: New Brand: Model:Reuse existing
Page 1 of 5
Hold volt: Resistance:DC: Phase: Amps:
Pick volt:
AC**: Volts:
Res:
GIV GIIIController Type:
2000
Date:
Technical Contact:
Job Name:
P.O. No.:
Controller No.:
Fixture No.:
Door Equipment No.:
Email:
Cell:
Job Address:
Company Name:
Contact:
Phone:
Phone:
Address:
Email:
Cell:
City: State/Prov.:
Job No.:
Est. No.:
controller and motor: feet
Volts: Phase: Amps:Blower motor
Hold volt:
**Long lead item
Traction Data FormVersion 2.1 - 03/28/2019
Traction data form - Version 2.2 - 03/28/2019
GAL Manufacturing Company LLC
50 East 153rd Street, Bronx, NY 10451
Phone: (718) 292 9000 Fax: (718) 292 2034
Web site: www.gal.com
LINE/LOAD CONDITIONING
MOTOR CONTROL PREFERENCE
SIGNAL FIXTURES
HOIST MOTOR
Motor data DC
Horse power:
Armature full load volts:
Armature full load amps:
RPM:
Field force volts:
Field weakening volts:
5 61 7 82 3 4
Motor: New Brand: Model:Reuse existing
Page 2 of 5
Field stand-by-volts:
Field connection (S, P, S/P):
Field resistance:
GAL supplied encoder kit Note: Encoder typically supplied by motor manufacturer. PPR: 2048/geared, 10000/gearless
Drive:
Isolation transformer by GAL Isolation transformer by others Line reactor
CAR POSITIONING/LEVELING
Governor to controller distance:
Reduced stroke buffer
<=49 Ft (15 M)
Tapeless Positioning System (12mm diameter live shaft governor required for tapeless selector)
<=114 Ft (35 M) <=164 Ft (50 M) <=246 Ft (75 M) <=328 Ft (100 M)
24 VAC 120 VAC
Fixture manufacturer: GAL
Other: Prewired COP (By GAL)
Send COP boards:
To fixture manufacturer With controller To customer before controller is shipped
Car IOs: Prewired cartop distribution station (Standard, includes cartop interface I/O boards)
24 VDC
Car lanterns: 24 VAC 120 VAC 24 VDC CE Micro com Audible signal: Chime
Hall lanterns: 24 VAC 120 VAC 24 VDC CE Micro com Audible signal: Chime
Lobby only This car up
Car position indicator:
CE Micro com Emotive
24 VAC 120 VAC 24 VDC
Hall position indicator:
CE Micro com Emotive
24 VAC 120 VAC 24 VDC
Total number of hall PIs:
Alternate floor markings (Specify on page 4)
Hall calls: Main Main and auxiliary
Discrete: 24 VAC 120 VAC 24 VDC
Serial: GAL (24 VDC) Fixtures by others (Must be 24 VDC)
Car calls: Main Main and auxiliary
CE Micro com voice annunciator
Note: Ripple filter (DC only) and Line filter included
GIOTTO
GAL Manufacturing Company LLC
Digital-Binary Multilight DL-20**
Load reactor
Remote car station
Car call security:
Card reader
Per car Per group
Always locked Switch in hall
Switch(es) in COP Switch(es) in hall/lobby station
Activation: Switch in car
Call buttons code entry
Lift Net/Galileo
Via:
GIV GIIIController Type:
**Long lead item
Digital-Binary Multilight DL-20**
GIOTTO & VOICE Alternate floor markings (Specify on page 4)
Voice annunciator discrete wiring Other:
Traction data form - Version 2.2 - 03/28/2019
OPTIONAL FEATURES
DOOR EQUIPMENT
Edge detector:
Door operator:
Door operation: Automatic:
Page 3 of 5
MONITORING
Front Rear
Automatic w/swing door: Front Rear
Power gate w/swing door: Front Rear
Manual: Front Rear
Power freight: Front Rear
With GAL operator: Front Rear
MOVFR Front Rear Front Rear Front Rear
MOVFE Front Rear Front Rear MONXT** Front Rear
HDLM* Front Rear
Front Rear
Dover HD-91* Front Rear
Other* *Note:Consult factory/provide operator wiring diagram.
Retiring cam: Mechanical: Electrical:Front Rear Front Rear Volts: AC DCAmps: Phase:
Power freight: Peelle* Front Rear Front Rear EMS* Front Rear
Attendant operation Attendant annunciator lights
Earthquake operation
Inconspicuous riser:* Car No.: , Car No.:
Code blue*
Mass. emergency medical
VIP/Priority service*Note: All risers supplied with same voltage and style of wiring
In car inspection
UPS power loss electronic brake pick
Taxi serviceCar switch operation
Sabbath service standard Sabbath service special
Emergency power: Intergroup # of groups:
# of cars per group: 1st*, 2nd, 3rd, 4th,UPS emergency power rescue system
High water sensing w/reset
Handicap buzzer: Always enable CC beep One trip enable with CC beep
Door closing indicator: Car Hall Remote governor set/reset: 120 VAC 24 VDC
Fire service complete indicator In service indicator Out of service indicator
CONTROLLER CABINET SELECTION
Enclosure requirements: Air conditioned enclosure
Machine room access or space limitations: Please specify space available below.
(2 cars max.)
5th
*This group will run after recall
w/ GAL operator By others
Note: Sequencing included with base controller
* Specify floors on page 4
Inputs:
Outputs:
Operations:
Front Rear By Others:
Dual fans
"S" button (NYC)
("A" size cabinet only)
Narrow door** @ floor marking Front Rear
Front door operator voltage (STD 230 VAC): 115 VAC
Rear door operator voltage (STD 230 VAC): 115 VAC
GAL Manufacturing Company LLC
Front Rear
2nd riser:*
Dual riser:*
3rd riser:*
Lift Net: Complete system Interface only
Hall calls: Hall call lockout
Switch(es) in hall/lobby station Card reader
Floor lockout (Hall + Car call lockout controlled together)
Overrides:
Activation:
Switch(es) in COP Switch(es) in hall/lobby station Card reader
Always locked Lift Net/GalileoSwitch in hall
Via:
Optional security: Hugs (patient abduction/wandering) Tugs (Robotics product delivery) Note: For floor mask security, provide specs or contact GAL.
Remote fire command: Devices:
Car No.: , Car No.: (2 cars max.)
Car No.: , Car No.: (2 cars max.)
Car No.: , Car No.: (2 cars max.)
Front
Front Rear
Smart tech* Front Rear
MOVFR CAN bus
MOVFE CAN bus
Otis 6970*
Otis AT-400*
Dover encore*
Courion iLearn*
Courion MP*
Front Rear
ECI/MAC Front Rear
**Long lead item
Cloud monitoring:
JRT monintoring:
Heavy door @ floor marking Front Rear
GIV GIIIController Type:
MONXT CAN bus** Front Rear
Traction data form - Version 2.2 - 03/28/2019
Page 4 of 5
EXISTING EQUIPMENT OVERLAY
ADDITIONAL EQUIPMENT
Car top inspection (Additional stand alone unit if required)
All switches Brackets Cams
Load weighing: Micelect
K-TechInterface only:
Rope diameter: 3/8" (10mm) 1/2" (13mm) 5/8" (19mm) Number of ropes:
Mechanical iimit switches:
Dry contacts Other LW type:
Wiring package: Traveling cable: Feet
Steel core hanging deviceUniversal bale mesh
Cross-Cancellation Cross-Assignment
Spare set of Galaxy controller boards
Note: Provide existing dispatch controller wiring diagram
Switches (Finals must be mechanical)Magnetic limit switches:
Finals
Single weave split rod grip
GAL Manufacturing Company LLC GIV GIIIController Type:
20' top of car wiring harnesses
NOTES:
Traction data form - Version 2.2 - 03/28/2019
Page 5 of 5
Overhead
Bottom
Top
Pit
Label
Floor
Label
Alt. floor
Height
Floor
Nbr.
Floor
F R F R F R F R
Floor OpeningsFloor Information
F R F R F R F R
Car Security
F R
Hall
F R
Floor
F R
Car
F R
Hugs
All front
All cars same as car 1Total height
F R F R F R F RAccess Switch
All rear
All cars same as car 1
All front All rear F
R
F
R
F
R
F
R
F R
Code
F R
VIP
Blue
F
R
F
R
Group Security
F R
F
R
IR
GAL Manufacturing Company LLC
Traction data form - Version 2.2 - 3/28/2019
F R F R F R F RF R F R F R F R
F R F R F R F R
GIV GIIIController Type: