TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation...

39
Download C.A.D models or contact us on COSSIGA.COM Page 1 TOWER BTG CHILLED AND HEATED BTG RF6 BTG RF9 BTG RF12 BTG RF15 RF HT BTG HT6 BTG HT9 BTG HT12 BTG HT15 Heated double glazed glass top, sides and front Heated rear sub frame Argon filled rear doors Sliding rear doors Deck forced refrigeration Three adjustable shelves Ticket strips on shelves and base Undershelf and canopy LED lights Integral condensor Sliding front doors - optional Deck forced heating SIngle glazed Sliding rear doors Four adjustable shelves Ticket strips on shelves and base Undershelf and canopy LED lights Sliding front doors - optional 505 153 560 708 25 719 178 80 745 750 1380 505 560 750 25 719 178 80 745 1380 600 750 900 1200 1500 600 750 900 1200 1500

Transcript of TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation...

Page 1: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 1

TOWER BTG CHILLED AND HEATED

BTG RF6BTG RF9BTG RF12BTG RF15RF

HT BTG HT6BTG HT9BTG HT12BTG HT15

Heated double glazed glasstop, sides and frontHeated rear sub frameArgon filled rear doorsSliding rear doors Deck forced refrigerationThree adjustable shelvesTicket strips on shelves and baseUndershelf and canopy LED lightsIntegral condensorSliding front doors - optional

Deck forced heatingSIngle glazedSliding rear doorsFour adjustable shelvesTicket strips on shelves and baseUndershelf and canopy LED lightsSliding front doors - optional

505

153

560708

25

719

178

80

745

750

1380

505

560

75025

719

178

80

745

1380

600

750

9001200

1500

600

750

9001200

1500

Page 2: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 2

TOWER BTG AMBIENT AND OPEN FRONT

BTG OR6BTG OR9BTG OR12

505

560

750

25

719

178

80

745

1380

505

153

560708

25

719

178

80

745

750

1380

600

750

9001200

1500

600

750

9001200

SIngle glazedSliding rear doorsFour adjustable shelvesTicket strips on shelves and baseUndershelf and canopy LED lightsSliding front doors - optionalAmbient converted from heatedAir removal fan installed in ceiling

Open front Stainless steel hinged rear doorsDeck forced refrigerationDouble glazed glass endsTwo adjustable glass shelvesTicket strips on shelves and baseUndershelf and canopy LED lights

OR

AB BTG AB6BTG AB9BTG AB12BTG AB15

Page 3: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 3

CABINET DIMENSIONS & SPECIFICATIONS

TOWER BTG SPECIFICATIONS

MODEL CABINET SHELvING OPERATING TEMP

POWERCORD

LENGTH

SHELF BASETRAY

FREQUENCY REFRIGERANT OPERATING CURRENT

CONNECTION vOLTAGE PACkED FOR SHIPPING

LENGTH [MM]

DEPTH[MM]

HEIGHT[MM]

DEG C W X D W X D LENGTH [MM]

DEPTH[MM]

HEIGHT[MM]

WEIGHT

BTGRF6 600 750 1380 3 + BASE 3-5 2200MM 495X445 540 x510 50/60 Hz 134A 4.2 AMP 10AMP 3 PIN PLUG 220-240v 700 830 1550 175

BTGRF9 900 750 1380 3 + BASE 3-5 2200MM 790X445 840 x510 50/60 Hz 134A 4.5 AMP 10 AMP 3 PIN PLUG 220-240v 1000 830 1550 224

BTGRF12 1200 750 1380 3 + BASE 3-5 2200MM 1095X445 1140 x 510 50/60 Hz 134A 5.0 AMP 10 AMP 3 PIN PLUG 220-240v 1300 830 1550 273

BTGRF15 1500 750 1380 3 + BASE 3-5 2200MM 1395X445 1440 x 510 50/60 Hz 134A 6.0 AMP 10 AMP 3 PIN PLUG 220-240v 1600 830 1550 329

BTGHT6 600 750 1380 4 + BASE 75-85 2200MM 495X445 540 x 510 50/60 Hz N/A 4.1 AMP 10 AMP 3 PIN PLUG 220-240v 700 830 1550 118

BTGHT9 900 750 1380 4 + BASE 75-85 2200MM 795X445 840 x 510 50/60 Hz N/A 6.2 AMP 10 AMP 3 PIN PLUG 220-240v 1000 830 1550 150

BTGHT12 1200 750 1380 4 + BASE 75-85 2200MM 1095X445 1140 x 510 50/60 Hz N/A 8.3 AMP 1O AMP 3 PIN PLUG 220-240v 1300 830 1550 182

BTGHT15 1500 750 1380 4 + BASE 75-85 2200MM 1395X445 1440 x 510 50/60 Hz N/A 10.4 AMP 15 AMP 3 PIN PLUG 220-240v 1600 830 1550 214

BTGAB6 600 750 1380 4 + BASE N/A 2200MM 495X445 540 x 510 50/60 Hz N/A 0.2 AMP 10 AMP 3 PIN PLUG 220-240v 700 830 1550 133

BTGAB9 900 750 1380 4 + BASE N/A 2200MM 795X445 840 x 510 50/60 Hz N/A 0.3 AMP 10 AMP 3 PIN PLUG 220-240v 1000 830 1550 133

BTGAB12 1200 750 1380 4 + BASE N/A 2200MM 1095X445 1140 x 510 50/60 Hz N/;A 0.4 AMP 10 AMP 3 PIN PLUG 220-240v 1300 830 1550 157

BTGAB15 1500 750 1380 4 + BASE N/A 2200MM 1395X445 1440 x 510 50/60 Hz N/A 0.5 AMP 10 AMP 3 PIN PLUG 220-240v 1600 830 1550 158

BTGOR6 600 750 1380 2 + BASE 2-4 2200MM 495X445 540 x510 50/60 Hz N/A 4.2 AMP 10 AMP 3 PIN PLUG 220-240v 700 830 1550 175

BTGOR9 900 750 1380 2 + BASE 2-4 2200MM 790x445 840 x 510 50/60 Hz 134A 4.5 AMP 10 AMP 3 PIN PLUG 220-240v 1000 830 1550 190

BTGOR12 1200 750 1380 2 + BASE 2-4 2200MM 1095x445 1140 x 510 50/60 Hz 134A 5.4 AMP 10 AMP 3 PIN PLUG 220-240v 1300 830 1550 212

Page 4: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 4

TOWER BTGRF9

1380

Page 5: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 5

TOWER BTGRF12

1380

Page 6: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 6

TOWER BTGRF15

1380

Page 7: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 7

TOWER BTGHT6

1380

Page 8: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 8

TOWER BTGHT9

1380

Page 9: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 9

TOWER BTGHT12

1380

Page 10: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 10

DRAINAGE - OPTIONAL

The condensate waste pipe may be plumbed directly to the building drainage system

To Waste

To Waste Water Drain

Condensate drain pipe

Page 11: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 11

BTG REAR vENTILATION

Ambient air intake throughright rear internally ducted through condenser face

Exhaust air extract throughleft rear internally ducted to environment

Rear ventilation

Separation To Wall

Rear intake and extract ventilation system Side mounted compressor

Front can be fully covered with custom panel joinery to suit environment

A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed hard up against a wall

Page 12: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 12

PLACEMENT GUIDES

Blocked air flow will retard operation on both HOT and COLD units

Ensure trays or plates are not blocking air flow at rear

Mechanical air flows, such as diffusers and fans can disturb the air curtain on open fronted units causing failure

Heat from other equipment and natural conditions, such as direct sunlight straight on units, can cause cooling to fail and overload compressor

Natural disruptive air flow suchas cross winds can disturb the air curtain on open frontedunits causing cooling to fail

Locations to avoid :

- Close to shop front exterior - In a high wind- In an outsdie location - Near any source producing excessive heat- In direct sunlight - Service units more frequently in dusty or polluted areas

CORRECT AIR FLOW INCORRECT AIR FLOW

CLEAR FLOW AIR FLOW BLOCKED

too much chilled airaround coil can createexcessive ice build up

NO AIR FLOW

Page 13: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 13

PLACED IN BENCH DETAIL

Dropped Into Benchtop

Placed Into Benchtop from rear

Parts removed

MODEL CUT OUT SIzE

BTG6 615 X 720

BTG9 915 X 720

BTG12 1215 X 720

BTG15 1515 X 720

Unit is dropped in to hole cut in bench top and supported by font and rear flange of unit.

Unit is slid into custom built frame from rear and supported by the sides of the unit base frame. L shaped supports shown in red in this example.Castors, front and side panels removed.

Rear panels / grill remain for personnel safety.

SupportSupport

Support

Page 14: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 14

COPS CLIP ON PANEL SYSTEM

Affinity Maple

Bliss Shitake

Burnished Wood

Easy install option to eliminate a nib wallSimply roll in and clip on

Clip on panels offered in routed 18mm MDFMelteca finish in three colour options600/900/1200/100 lengths options with end panels

Page 15: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 15

COPS CLIP ON PANEL SYSTEM

Bottom edge sits flush with bottom of panel

Double sided velcro

Clips screw fixed topanel

end panels

Integrated Clip System - Bracket fixing to joinery panels

Page 16: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 16

SELF SERvICE SYSTEM

SELF SERvICE SYSTEM

Each unit is self containedRoll-in - Roll-outInstall in minutesNo on site joinery work requiredEase of cleaning and servicingMobile and flexibleEasy to upgrade front panel designCustom branding stripRear service or against wallAll parts as optional component kitsIdeal solution for temporary events

Optional bottom shelf kit for chilled unitsEnsure chilled units are kept well ventilated

vent required through front panel

Optional bottom meltica shelf kit - BY OTHERS

Optional rear loading shelf kit 200mm deep

Optional bottom meltica shelf kit - BY OTHERS

Page 17: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 17

BTG ACCESSORIES

Top Mounted Controller Panel

Price Tabs

For against wall installationsSold individually

Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20

Front and Rear Work ShelvesStainless SteelSold individually

Front

Rear

600 - 900 mm - 1200 mm - 1500 mm

600 - 900 mm - 1200 mm - 1500 mm

300 mm

250 mm

Castor Extension kit

370

mm

280

mm

90 m

m

Increases cabinet height to 1660mm

Set of four, uses existing castors, includes fixing bolts and washers

Base Tray - Heated Units

Tong Holder

Bag Holder

Humidity Dish

100 mm

190 mm

80 mm

180

mm

220 mm

190 mm

105 mm

75 mm

Stainless SteelDrop into counter tray raceSold individually

Stainless SteelFor heated unitsSold in pairs

Stainless SteelPerforated lid is removable

Page 18: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 18

MERCHANDISE TRAY

Merchandise TrayClip on stainless steel tray for allfree standing units

Attached to front of unitBuilt in ticket stripAngled base for maximum display

Page 19: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 19

CHARCUTERIE RACk

Charcuterie RackStainless steel heavy duty shelf brackets 3 x 20 dia Stanless steel tubes

Replaces existing shelves to allow hanging of cured meats, cheeses etc.Available in 900 and 1200 lengths onlyMaximum of 50kgsHooks not included

190mm190mm

Weight to be spread evenly over front, middle and rear

rods

Page 20: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 20

MIRROR FILM

Applied to the inside glass rear doors

Suitable for heated and chilledunits

Mirror film adhered to inside of rear door glass

Mirror film adhered to inside of rear door glass

FREE STANDING UNITS BENCHTOP UNITS

Blocks work areasbehind units

Add depth toyour displays

Page 21: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 21

BTG SHELvINGGlass Shelf OptionsStandard wire racks are removed and replaced with 6mm toughened glass panes

Stainless Steel glass shelf support bracket

MODEL GLASS DEPTHMM

DEPTHMM

PER SHELFPANES

SHELvES TOTAL PANES

BTGRF6 6MM TOUGHENED - POLISHED EDGES 450 240 2 3 6

BTGRF9 6MM TOUGHENED - POLISHED EDGES 450 490 2 3 6

BTGRF12 6MM TOUGHENED - POLISHED EDGES 450 540 2 3 6

BTGRF15 6MM TOUGHENED - POLISHED EDGES 450 690 2 3 8

BTGHT6 6MM TOUGHENED - POLISHED EDGES 450 240 2 4 8

BTGHT9 6MM T(OUGHENED - POLISHED EDGES 450 690 2 4 8

BTGHT12 6MM TOUGHENED - POLISHED EDGES 450 540 2 4 8

BTGJT15 6MM TOUGHENED - POLISHED EDGES 450 690 2 4 8

Pie TraysStainless Steel Construction

PIE TRAYS

MODEL NO. OF SHELF TRAYS

WIDTH MM

DEPTHMM

PERSHELF

TOTAL

BTGHT6 4 PER SHELF 120 445 4 16

BTGHT9 6 PER SHELF 130 445 6 24

BTGHT12 9 PER SHELF 120 445 9 36

Page 22: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 22

GASTRO PAN RACk

1 Rack 1x 1/1 pan One rack with full size pan

1 Rack 1 RackOne rack with drop in divider

1 Rack 2 x 1/2 pan One rack 2 x half pans

1 Rack 5 x 1/9 pans 3 x 16 pansOne rack varrious size pans with divider

GASTRONORM PAN SYSTEM

MODEL PAN DEPTH RACkS NO.

BTG 6 65MM 1X 1/1

BTG 9 65MM 2 X 1/1

BTG 12 65MM 3 X 1/1

BTG 15 65MM 4 X 1/1

Page 23: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 23

COLOUR WRAP OPTIONS

- COUNTER TOP MODEL - CURvED OR SQUARE

FREE STANDING - CURvED OR SQUARE

WRAP TRIMMINIG

FREE STANDING BEHIND NIB WALL - CURvED OR SQUARE

DROP IN COUNTER TOP MODEL - CURvED OR SQUAREall exterior visible areas covered

all exterior visible areas covered all exterior top visible areas covered

2mm gap left around rear frame

Rear of units cut around serial number plate, exhaust fan and controller

all exterior top visible areas covered

Page 24: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 1

TOWER TOWER COUNTER SERIES

STG RF6STG RF9STG RF12STG RF15

STG HT6STG HT9STG HT12

RFDeck forced refrigerationSliding doors front and rearDouble glazedTwo adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsIntegral condensorSelf evaporatingSolid glass front - optional

HTSliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optional

Page 25: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 2

AB

BM

Sliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optionalAmbient converted from heatedAir removal fan installed in ceiling

Sliding doors front and rearOverhead halogen lightsWet / dry element in baseSingle glazed glassSolid glass front - optional

STG AB6STG AB9STG AB12

STG BM6STG BM9STG BM12

TOWER TOWER COUNTER SERIES

Page 26: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 3

CABINET DIMENSIONS & SPECIFICATIONSMODEL CABINET SHELVING SHELVING SIzES REFRIGERANT TOTAL

FOODOPERATING CURRENT

CONNECTION VOLTAGE PACkED FOR SHIPPING

LENGTH [MM]

DEPTH[MM]

HEIGHT[MM]

CUTOUTS

TOP 2ND 3RD BASE 100MMUNITS

LENGTH [MM]

DEPTH[MM]

HEIGHT[MM]

WEIGHT[kG]

CUBE

STGRF6 600 650 925 615x620 2+BASE 490x460 490x460 545x415 134A 55 3.3AMP 10AMP 3 PIN PLUG 220~240V 700 730 1450 115 0.69

STGRF9 900 650 925 915x620 2+BASE 790x460 790x460 845x415 134A 84 3.7AMP 10AMP 3 PIN PLUG 220~240V 1000 730 1450 136 0.98

STGRF12 1200 650 925 1215x620 2+BASE 1090x460 1090x460 1145x415 134A 121 4.3AMP 10AMP 3 PIN PLUG 220~240V 1300 730 1450 164 1.27

STGRF15 1500 650 925 1515x620 2+BASE 1390x460 1390x460 1445x415 134a 154 4.5AMP 10AMP 3 PIN PLUG 220~240V 1600 730 1450 186 1.57

STGHT6 600 650 925 615x620 3+BASE 490x460 490x460 490x460 545x415 55 4.6AMP 10AMP 3 PIN PLUG 220~240V 700 730 1100

STGHT9 900 650 925 915x620 3+BASE 790x460 790x460 790x460 845x415 84 6.2AMP 10AMP 3 PIN PLUG 220~240V 1000 730 1100

STGHT12 1200 650 925 1215x620 3+BASE 1090x460 1090x460 1090x460 1145x415 121 8.3AMP 10AMP 3 PIN PLUG 220~240V 1300 730 1100

STGAB6 600 650 925 615x620 3+BASE 490x460 490x460 490x460 545x415 55 0.2AMP 10AMP 3 PIN PLUG 220~240V 700 730 1100

STGAB9 900 650 925 915x620 3+BASE 790x460 790x460 790x460 845x415 84 0.3AMP 10AMP 3 PIN PLUG 220~240V 1000 730 1100

STGAB12 1200 650 925 1215x620 3+BASE 1090x460 1090x460 1090x460 1145x415 121 0.4AMP 10AMP 3 PIN PLUG 220~240V 1300 730 1100

STGBM9 900 650 925 915x620 9.9AMP 15AMP SUPPLY LEAD ONLY 220~240V 1000 730 1100

STGBM12 1200 650 925 1215x620 11.0AMP 15AMP SUPPLY LEAD ONLY 220~240V 1300 730 1100

STGBM15 1500 650 925 1515x620 15.0AMP 30AMP SUPPLY LEAD ONLY 220~240V 1600 730 1100

TOWER TOWER COUNTER SERIES

Page 27: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 4

STG RF6

STG RF6 STG RF9

STG RF12 STG RF15

STG RF9STG RF12STG RF15

TOWER STG RF

Page 28: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 5

TOWER STG HT STG AB

STG HT6 STG AB6

STG HT9 STG AB9

STG HT12 STG AB12

Page 29: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 6

TOWER STG BM

Page 30: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 7

REMOTE INSTALLATION AND SERVICES

Units are self evaporating to a receptacle in the condensor unitn areas of high humidity units should be plumbed directly to a waste.

Plumbed Receptacle

Maximum 150 mm above finished floor level

Drainage to building waste

Building waste by client

Receptacle placed under unit

3/8” pipe max run 1500 mm

condensate drainto four litre container

Vertical pipe runs are not recommended

Pipe runs over 150mm : Expansion valve will need to be fitted Correctly sized condensing unit fitted Correct pipe size determined

Page 31: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 8

JOINERY AIR FLOW CONSIDERATIONS

350 mm

260

mm

varies

vari

es

Hole Cut to meet condenser face

Front Vented Rear Vented

Closed rear. Front vented

Intake and extract vents.Min 400mm x 400mm openarea.

Joinery divider panelproviding sealed air intakeplenum with cutout to meetcondenser face

Page 32: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 9

ExTRACTION FAN

Extract hot air from closed box joinery

Fan and power cable supplied, screw fixed to joinery

Electrical power cord 2000mm 3 pin 10 amp 1 phase socket required

Fan 230v ~ 50Hz - 60Hz - 19 Watt in stainless steel case with switch

JOINERY ExTRACTION FAN

Page 33: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 10

DROP IN COUNTER TOP CUT OUT DETAILS

Supplied 5mm PVCwedge strip to sidesfor drop-in unit.No glue or sealant required

150 mm

Cut out see table

Supplied 5mm PVCwedge strip to sidesfor drop-in unit

Cut out 620 mmmin 20 mm

min 20 mm

Condensor unit545w x 485d x 390h(RF6 485w x 485d x 335h)

ALLO

W 4

00 m

m

Open at rear.

Remove feet for alldrop-in installations

Cut out 585 mm

Cut out 525 mmmin 75 mm

min 75 mm

Condensor unit545w x 485d x 390h(RF6 485w x 485d x 335h)

RF6 Cut out 525 mmRF6 Cut out 525 mm

ALLO

W 4

00 m

m

Open at rear.

Page 34: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 11

JOINERY TO REAR WALL WITH VENT

Horizontal vent in cabinet top for hot air extract

Electric biscuit fans can also be fitted to provide mechanical extract

Ambient air ducted in to compressor face through air plenum space

Joinery divider panel providing sealed air intake plenum with cut out to meet condensor face

Allow access for cleaning, servicing and waste evaporator water removal

Ambient air is drawn into front vented area Hot air must escape joinery cabinet A horizontal vent should be used behind the unit

Vent must be at least 100mm deep and as wide as unit

Page 35: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 12

AIRFLOW AND PLACEMENT GUIDE LINES

Blocked air flow will retard operation on both HOT and COLD units

Ensure trays or plates are not blocking air flow at rear

Heat from other equipment and natural conditions can cause cooling failures and overheating of compressors

Locations to avoid are :

Close to shop front exterior In an outside location In direct sunlight In a high cross wind area Near any source producing excessive heat

CORRECT AIR FLOW INCORRECT AIR FLOW

CLEAR FLOW

NO AIR FLOW

AIR FLOW BLOCKED

too much chilled airaround coil can createexcessive ice build up

Page 36: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 13

Ventilation Grill

STG ACCESSORIES

Top Mounted Controller Panel

Price Tabs

450

mm

450 mm

Base Tray - Heated Units

Tong Holder

Bag Holder

Humidity Dish

100 mm

190 mm

80 mm

180

mm

220 mm

190 mm

105 mm

75 mm

For against wall installationsSold individually

Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20

Stainless SteelSold individually

Stainless SteelDrop into counter tray raceSolid individually

Stainless SteelDrop into counter tray raceSold individually

Stainless SteelFor heated unitsSold in pairs

Stainless SteelPerforated lid is removable

Page 37: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 14

Applied to the inside glass rear doors

Suitable for heated and chilledunits

Mirror film adhered to inside of rear door glass

Mirror film adhered to inside of rear door glass

FREE STANDING UNITS BENCHTOP UNITS

Blocks work areasbehind units

Add depth toyour displays

MIRROR FILM

Page 38: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 15

BENCHTOP DROP IN

BENCHTOP DROP IN

BENCHTOP

BENCHTOP

CC5 -TBDI

STG -TBDI

CC5 -TBC

STG -TBC

Provides thermal separation between hot and cold units with minimum spacing

Provides a continuous look

20mm Clear polycarbonate with polished edges

THERMAL BARRIERS

Thermal spacer barriers

Page 39: TOWER BTG CHILLED AND HEATED RF BTG RF15 - Cossiga...panel joinery to suit environment A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed

Download C.A.D models or contact us on COSSIGA.COMPage 16

Pie Trays

Stainless Steel ConstructionPlaced on shelves for heated food items

PIE TRAYS PIE TRAYS

MODEL CODE qUANTITY 1ST SHELFDEPTH

2ND SHELFDEPTH

3RD SHELFDEPTH

TOTAL SHELFWIDTH

STGHT6 AA16015 4 Per Shelf 325MM 365MM 395MM 12 Trays 120MM

STGHT9 AA16016 6 Per Shelf 325MM 365MM 395MM 18 Trays 130MM

STGHT12 AA16017 9 Per Shelf 325MM 365MM 395MM 27 Trays 120MM

Gastro Norm System

Stainless Steel ConstructionAngled display view

GASTRO NORM

MODEL CODE qUANTITY DIMENSIONS PAN DEPTH

STGHT6 F92-315 2 Per Unit 265MM x 325MM PANS AND FRAME 65MM

STGHT9 F92-316 3 Per Unit 265MM x 325MM PANS AND FRAME 65MM

STGHT12 F92-317 4 Per Unit 265MM x 325MM PANS AND FRAME 65MM

STG HEATED UNIT ACCESSORIES