Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command...
Transcript of Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command...
![Page 1: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/1.jpg)
2015 Pierce Arrow XT
82,000 lbs
48’ 5-1/2” long
1500 GPM single stage Pierce PUC
pump
480 Gallon water tank
A Pierce PUC pump is operated via a Rear Engine Power Take Off (REPTO). Instead of being
driven from a transmission PTO, anytime the engine is turning, the REPTO is operating and
the driveshaft between it and the electro
the “Water Pump” switch engages the clutch and thus turns the pump.
this is the driveshaft that comes from between the engine and transmission at the 1 O’Clock
position.
The following will address some of the signi
with PUC’s (E17/P72 & T14/L06)
IMPORTANT- DO NOT PLACE TRANSMISSION IN DRIVE
drive will DISABLE the hand throttle
With truck running, in neutral,
toggle switch up once until light
illuminates
Page 1 of 28
Tower 14 (L-06)
Arrow XT PUC (Pierce Ultimate Configuration)
1500 GPM single stage Pierce PUC
700’ 5” hose
Standard 1-3/4” hose loads
250’ 5” Dead lay (transverse)
65 Gallon fuel tank
Pierce PUC pump is operated via a Rear Engine Power Take Off (REPTO). Instead of being
driven from a transmission PTO, anytime the engine is turning, the REPTO is operating and
the driveshaft between it and the electro-magnetic clutch for the pump is turn
the “Water Pump” switch engages the clutch and thus turns the pump. When tilting the cab,
this is the driveshaft that comes from between the engine and transmission at the 1 O’Clock
The following will address some of the significant differences that have been encountered
PUC’s (E17/P72 & T14/L06) and how to engage/operate the pump.
DO NOT PLACE TRANSMISSION IN DRIVE for stationary pumping
DISABLE the hand throttle at the panel…. But you are PUMP AND ROLL ready.
Pump is engaged when
this light is green
July 2016
(Pierce Ultimate Configuration)
3/4” hose loads
250’ 5” Dead lay (transverse)
Pierce PUC pump is operated via a Rear Engine Power Take Off (REPTO). Instead of being
driven from a transmission PTO, anytime the engine is turning, the REPTO is operating and
magnetic clutch for the pump is turning. Activating
When tilting the cab,
this is the driveshaft that comes from between the engine and transmission at the 1 O’Clock
ficant differences that have been encountered
for stationary pumping. Selecting
you are PUMP AND ROLL ready.
Pump is engaged when
this light is green
![Page 2: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/2.jpg)
2
The pump panel is located in Compartment #1, the LED light at the top in the image will
illuminate when the pump is engaged.
![Page 3: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/3.jpg)
3
Once pump is engaged, press the “CONTROL MODE” button once, and the “PRESSURE
CONTROL” light will illuminate indicating throttle is ready to use in pressure mode. If button
is pressed a second time, the throttle will switch to RPM mode. T14 has no discharge pressure
relief valve and will automatically throttle up and down to maintain the pressure that is set.
IF you press “PRESET” the current preset pressure is 165 psi.
![Page 4: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/4.jpg)
4
Driver and passenger side 5” Supply inlets are opened via these electronic valves. Hold
“OPEN” button to introduce water. Pump will automatically throttle down and maintain set
pressure as water pressure from supply line is introduced. BE AWARE, it will only throttle
down to idle engine speed. You may still have to GATE DOWN your discharge. You will not
have to adjust the throttle if you have set the pressure governor correctly.
The preset values on these valves will open them to 50% (1/2 open).
![Page 5: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/5.jpg)
5
1- Throttle
2- 5” intake valve controls
3- Intake valve bleeder valves (R & L)
4- Primer
5- “Manual” “pump shift” switch
6- Aerial Discharge Valve
1
2 5
4
3
6
![Page 6: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/6.jpg)
6
Electronic Valves - Presets are at 25, 50, & 75% open.
5” intake bleeder valves (at pump panel)
![Page 7: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/7.jpg)
7
“Manual” “pump shift” override. IF cab switch fails to work, lift cover and flip switch.
Continue operations as normal. You should still see the “pump illumination” light
come on over the panel and hear the pump engage.
As a note, it is not recommended by Pierce to us the apparatus pump for hose testing
(see Pierce PUC Operation and Maintenance Manual, pg 4-7 section 4-4 for a caution
note).
.
![Page 8: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/8.jpg)
8
Additional Control Differences – CAB TILT
Cab tilt controls are on passenger side in compartment 6.
![Page 9: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/9.jpg)
9
The pump (blue arrow) on a PUC is visible by tilting the cab. The PTO shaft (red arrow)
is shielded as it is rotating any time the engine is running.
Front of apparatus
![Page 10: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/10.jpg)
10
Additional Control Differences – GENERATOR
To engage generator, first press “AERIAL PTO” then “GEN PTO” while the truck is not in
motion, then press “GEN ON/OFF” so that both are illuminated. The Generator must be on
for the “DS FLOOD”, “PS FLOOD”, and “FRONT BASKET FLOOD” lights to work. The “REAR
SCENE” lights will work without them (12V).
1 2
![Page 11: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/11.jpg)
11
Extrication Battery Charging Plug: In compartment 10 there is a quad receptacle with one
side painted red. The batteries for the extrication tools in this compartment are normally
plugged into the non-painted side which is connected to shore power. IF on-scene additional
charging is necessary, the power strip may be plugged into the red side and then with the
Generator ON and the PS FLOOD lights ON the red receptacles will be powered up.
![Page 12: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/12.jpg)
12
AERIAL OPERATION
Aerial operation is essentially the same as L04 & 05. Cab controls include:
1. AERIAL MASTER
2. AERIAL PTO
3. FRONT WHEEL LOCK (Brake)
![Page 13: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/13.jpg)
13
The FRONT WHEEL LOCK can be left on (per pierce training rep) as it will shut off when the
ignition is turned off. When the ignition is turned back on it will turn on (you’ll hear the air
being applied to the front brakes). When the spring brakes are turned off, the front wheel
lock function will also turn off. When the spring brakes are re-applied, the FRONT WHEEL
LOCK will re-engage.
![Page 14: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/14.jpg)
14
Single control for stabilizers. Stabilizers do not have pins.
![Page 15: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/15.jpg)
15
Controls for air to the tip are to the right of the base of the ladder. There is still a valve on the
cylinder under the aerial on the turntable.
![Page 16: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/16.jpg)
16
Lyfe Support /Lyfe Ladder system for stokes basket and ladder attachment for parapet walls.
This is typically left stowed in the bucket on the floor. If left on and you “Auto Stow” the
monitor with the fog nozzle, the nozzle will hit the bracket (see picture below). Note controls
are similar to other aerials and you have the ability to control the left (engineer’s side) nozzle
here via switches here, switches at the pedestal, or….
![Page 17: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/17.jpg)
17
Manually, or….
![Page 18: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/18.jpg)
18
Electronically at the nozzle
![Page 19: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/19.jpg)
19
Fog nozzle is a 300-2000 GPM automatic nozzle for 80-120 PSI. Currently the nozzle is set at
the 100psi setting. Use flow meter!
Per TFT the “Lower PSI setting is for maximum flows” and the “Higher PSI setting is for
increasing reach”.
![Page 20: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/20.jpg)
20
Platform leveling (tilt up) switches. Both are momentary, so to raise you have to hold both
switches until tilted to desired spot.
![Page 21: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/21.jpg)
21
Access panel for manual hydraulic controls for outriggers.
Manual controls for the ladder are still at the base of the aerial on the platform.
![Page 22: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/22.jpg)
22
Other Cab Operations –
Siren control head…In addition to mechanical siren operated by the foot switch or officers
push button, there is an electronic siren. Push one button to turn it on & cycle it, push both
to turn it off.
Note: The air horn is run via the steering wheel horn switch or officers push button. A floor
switch will be installed by fleet at a future service.
![Page 23: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/23.jpg)
23
There is a backup and right turn camera. The right turn camera activates with the turn signal,
the back up with the transmission in Reverse. You can manually activate them by pressing
“Video” on the command zone screen. You can change which cameras (or combination
thereof) are displayed with the “QUAD” button.
The Command Zone Display may be dimmed manually by going through the menu. Or, if the
headlights are kept on, as on most apparatus, cycle the headlight switch off and back on and
the display will auto dim to the “night display brightness” setting.
![Page 24: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/24.jpg)
24
Two emergency master switches.
NOTE: IF the RotoRay is too bright at night, you may disable it using the over head switch for
it.
![Page 25: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/25.jpg)
25
DIFF LOCK - This is a Driver Controlled Differential Lock (DCDL), not to be confused with the
Inter-Axle Differential LOCK (IADL). This button when pressed activates a “locker” in the rear
axle of the tandem to further combat loss of drive traction. Only activate it without wheel
slippage (either speed of zero or wheels spinning at the same speed). Also follow these
instructions:
Only engage DCDL under poor road conditions
Do not engage during downhill operation
Do not engage or operate above speeds of 25 mph.
![Page 26: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/26.jpg)
26
IADL Switch (right knee area)
For further information on the operation / function of the IADL and DCDL see:
http://www.winningwithemail.com/content/7115/images/tp9238.pdf
![Page 27: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/27.jpg)
27
OTHER RESOURCES:
Pressure Governor Interactive Video
http://www.eqsim.com/pierce/pressuregovernor.html
PUC Manual*
https://www.pierceparts.com/index.php/library/application/pdf%3B%20charset%3Dbin
ary/1462808943_pm-p-om420-0516_web_.pdf?attachment
Aerial Manual*
https://www.pierceparts.com/index.php/library/application/pdf%3B%20charset%3Dbin
ary/1467133534_pm-a-om033-0616_web_.pdf?attachment
Arrow XT Manual*
https://www.pierceparts.com/index.php/library/application/pdf%3B%20charset%3Dbin
ary/1463598778_pm-c-om014-atx-0516_web_.pdf?attachment
Review of DD13 Regen system*
https://www.pierceparts.com/index.php/library/application/octet-
stream/1465503833_detriotregeneration2013.exe?attachment
* These resources are from pierceparts.com. If needed click,” logon as guest” and locate manuals under technical
support tab.
![Page 28: Tower 14 (L-06) 2015 Pierce Arrow XT PUC (Pierce Ultimate ...€¦ · “Video” on the command zone screen. You can change which cameras (or combination thereof) are displayed with](https://reader033.fdocuments.us/reader033/viewer/2022053013/5f0ffc047e708231d446dd85/html5/thumbnails/28.jpg)
28
Instruction Notes:
Heavier than L-02&L-03 at 82000 lb and longer than L-02 (48’ 5-1/2”)
Cab – two emergency master switches – one down low E-M and standard
overhead
Pumping- similar to E16. Pump stationary in neutral. If put in gear (Drive) it goes
into “Pump and Roll Mode” and disables the hand throttle, and yes, it will pump
and roll when you do this (wildland).
Rear axle – same IAD like other towers, activate with switch at right knee. Also
had DCDL, Driver Controlled Differential Lock, aka “Locker” in rear axle. Can be
used with IAD, or without, engage w/o axles spinning, never more than 25mph
indicated speed, not while going downhill, only low traction.
Aerial operations – Similar to L04/05. Single control, no pins on outriggers. Cab
switches for PTO and Master
120 V generator / lights. Rear “scene” is 12v will work when button pushed. All
others are 120 v requiring generator.
Valve presets
TPMS (valve stem caps, illuminate red when pressure < 8psi below) – To be
removed at future date?
Cameras
Inlet valve bleeders
No foam
Differences in headsets. Individual volume and PTT switches
Extrication tools are all battery powered, no hydraulics extrication tools on truck
Electronic siren…. Push button on left and get siren on. Push again to cycle.
Push both buttons to get it off.
Manual override valves – outriggers and aerial
Platform tilt (stowed)
Air supply
Nozzle (changeable tip setting)
Valve presets (discharges) at 25/50/75% open
Intake preset at ~50% open
Pressure gov preset is at 165 psi
Aerial capacity same as other Towers
Estimated times (groups of two):
Cab familiarize 10 min
Pump – 1 time each, 15 min total (7-1/2 ea)
Setup aerial – 1 time each, 20 min total (10 min each)
Tilt cab one time (second flying of aerial), add 5 min to show PTO and pump