TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE...

57
ACCESSORIES FOR ICP TYPE VARIAN T T O O R R C C H H S S N N E E B B U U L L I I Z Z E E R R S S S S P P R R A A Y Y C C H H A A M M B B E E R R S S If you wish to use high quality products and save money For further information, contact : TecDev Le Villaret CH 1432 Belmont s/ Yverdon Switzerland Phone +41 (24) 435 22 02 Fax : +41 (24) 435 22 03 Email : [email protected]

Transcript of TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE...

Page 1: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

AACCCCEESSSSOORRIIEESS FFOORRIICCPP TTYYPPEE VVAARRIIAANN

TTOORRCCHHSS

NNEEBBUULLIIZZEERRSS

SSPPRRAAYY CCHHAAMMBBEERRSS

If you wish to use high quality products and save money

For further information, contact :TecDev Le Villaret CH 1432 Belmont s/ Yverdon Switzerland

Phone +41 (24) 435 22 02 Fax : +41 (24) 435 22 03 Email : [email protected]

Page 2: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

2

INDEX

TUOOTTHHEERR PPRROODDUUCCTTSS AAVVAAIILLAABBLLEEUT .............................................................................................................. EERRRROORR!! BBOOOOKKMMAARRKK NNOOTT DDEEFFIINNEEDD..

TUGGEENNEERRAALLEE PPRREESSEENNTTAATTIIOONNUT .............................................................................................................................................................................................................................................. 66TU§ UT TUHow to Order & Payment TermsUT ........................................................................................................ 7TU§ UT TUDelivery TermsUT .................................................................................................................................. 7TU§ UT TUGuaranteed Money Back Performance OfferUT...................................................................................... 7TU§ UT TUTorch repair serviceUT........................................................................................................................... 7TU§ UT TUTrademarksUT ....................................................................................................................................... 7

TUWWHHYY CCHHOOOOSSEE GGLLAASSSS EEXXPPAANNSSIIOONN PPRROODDUUCCTTSS??UT ............................................................................................................................................................................ 88TU§ UT TUQuality by designUT............................................................................................................................... 9

TUNNEEBBUULLIIZZEERRSSUT ............................................................................................................................................................................................................................................................................................ 1100TU§ UT TUHow to choose the most suitable nebulizer for your applicationUT ........................................................ 10TU§ UT TUGlass Expansion Nebulizer Designations...What do they all mean?UT ................................................. 10TU§ UT TUNebulizers for Aqueous and Organics AnalysesUT............................................................................... 11TU§ UT TUNebulizer for HFUT ................................................................................................................................ 13

TUNNEEWW EELLUUOO :: FFOORR NNEEBBUULLIIZZEERR CCLLEEAANNIINNGGUT .............................................................................................................................................................................................. 1144

TUNNEEWW CCAAPPRRIICCOORRNN :: AARRGGOONN HHUUMMIIDDIIFFIIEERRUT.......................................................................................................................................................................................... 1144

TUSSPPRRAAYY CCHHAAMMBBEERRSS ,, QQUUAALLIITTYY,, UUNNIIFFOORRMMIITTYY AANNDD EEFFFFIICCIIEENNCCYYUT ........................................................................................................................ 1155TU§ UT TUHow to choose the most suitable spray chamber for your applicationUT ............................................... 15TU§ UT TUTracey cyclonic chambersUT ............................................................................................................... 15TU§ UT TUTwister cyclonic chambersUT............................................................................................................... 16TU§ UT TUCinnabar cyclonic chambersUT ............................................................................................................ 16TU§ UT TUTwinnabar cyclonic chambersUT......................................................................................................... 16TU§ UT TUWHY TO CHANGE YOUR RF COILSUT.............................................................................................. 18TU§ UT TUADVANTAGE OF GLASS EXPANSION RF COILS:UT......................................................................... 18

TUNNEEWW HHEELLIIXX :: OO RRIINNGG FFRREEEE NNEEBBUULLIIZZEERR FFIITTTTIINNGG !! UT...................................................................................................................................................................... 1188

TUVVAARRIIAANN LLIIBBEERRTTYY SSEERRIIEESS 110000//220000//112200//115500//222200 AANNDD VVIISSTTAA ––RRAADDIIAALLUT .......................................................................................................... 1199TU§ UT TUTorchsUT ............................................................................................................................................. 19TU§ UT TUSpray chamber with O ringUT .............................................................................................................. 20TU§ UT TUSpray chamber without O Ring « HELIX SYSTEM »UT ........................................................................ 21TU§ UT TUNebulizersUT ....................................................................................................................................... 23TU§ UT TUKitsUT.................................................................................................................................................. 25

TUVVAARRIIAANN VVIISSTTAA --AAXXIIAALLUT ................................................................................................................................................................................................................................................................ 2255

TUVVAARRIIAANN VVIISSTTAA --AAXXIIAALLUT ................................................................................................................................................................................................................................................................ 2266TU§ UT TUTorchesUT ........................................................................................................................................... 26TU§ UT TUSpray chamber with O ringUT .............................................................................................................. 28TU§ UT TUSpray chamber without O Ring « HELIX SYSTEM »UT ........................................................................ 29TU§ UT TUNebulizersUT ....................................................................................................................................... 30TU§ UT TUKitsUT.................................................................................................................................................. 32

TUVVAARRIIAANN LLIIBBEERRTTYY IIII --AAXXIIAALLUT .................................................................................................................................................................................................................................................. 3344TU§ UT TUTorchesUT ........................................................................................................................................... 34TU§ UT TUSpray chamber with O ringUT .............................................................................................................. 35

Page 3: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

3

TU§ UT TUSpray chamber without O Ring « HELIX SYSTEM »UT ........................................................................ 36TU§ UT TUNebulizersUT ....................................................................................................................................... 37TU§ UT TUKitsUT.................................................................................................................................................. 40

TUVVAARRIIAANN UULLTTRRAAMMAASSSSUT .................................................................................................................................................................................................................................................................. 4411TU§ UT TUTorchsUT ............................................................................................................................................. 41TU§ UT TUSpray chamber with O ringUT .............................................................................................................. 43TU§ UT TUSpray chamber without O Ring « HELIX SYSTEM »UT ........................................................................ 44TU§ UT TUNebulizersUT ....................................................................................................................................... 45TU§ UT TUKitsUT.................................................................................................................................................. 47TU§ UT TUConesUT ............................................................................................................................................. 47

TUVVAARRIIAANN IICCPP//MMSSUT .................................................................................................................................................................................................................................................................................... 4488TU§ UT TUTorchesUT ........................................................................................................................................... 48TU§ UT TUSpray chamber with O ringUT .............................................................................................................. 48TU§ UT TUNebulizersUT ....................................................................................................................................... 48

TURRFF CCOOIILLSS AANNDD TTOOLLLL FFOORR VVAARRIIAANN IICCPPUT .......................................................................................................................................................................................................... 5500

TUNNEEBBUULLIIZZEERR AANNDD CCHHAAMMBBEERR CCOONNNNEEXXIIOONNUT ................................................................................................................................................................................................ 5511TU§ UT TUEasy lock argon CONNECTORUT ....................................................................................................... 51

TUTTEEFFLLOONN TTUUBBEESS AANNDD CCOONNNNEEXXIIOONN FFOORR CCHHAAMMBBEERRSSUT ............................................................................................................................................................ 5522TU§ UT TUUNIFIT ConnectorUT ........................................................................................................................... 52TU§ UT TUEzyLock for thermostated chamberUT.................................................................................................. 52

TUOO RRIINNGG AANNDD CCOONNNNEEXXIIOONN FFOORR TTOORRCCHHSSUT .................................................................................................................................................................................................. 5533

TUSSAAFFEETTYY CCCCEESSSSOOIIRRIIEESSUT ............................................................................................................................................................................................................................................................ 5533

TURRFF CCOOIILLSS :: GGEENNEERRAALLIITTYYUT ...................................................................................................................................................................................................................................................... 5544TU§ UT TUWhy to change your RF CoilsUT .......................................................................................................... 54TU§ UT TUAdvantage of Glass Expansion RF Coils:UT......................................................................................... 54TU§ UT TUThe role of the RF CoilsUT................................................................................................................... 54TU§ UT TUBenefits of maintaining your RF CoilsUT .............................................................................................. 55TU§ UT TUadvantage of Glass Expansion RF CoilsUT .......................................................................................... 56TU§ UT TUglass expansion Installation tool kit for coilsUT ..................................................................................... 57

Page 4: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

4

OOTTHHEERR PPRROODDUUCCTTSS AAVVAAIILLAABBLLEE

STANDARD AAS-ICP-GC ANALYTIKA exclusive distributor£ Primary CRM standards from CZECH METROLOGY INSTITUT£ Standards CRM AAS, ICP, IC£ Hight purity acids£ Standards AAS, ICP £ Matrix modifier£ Standards GC, GC/MS £ Standards on custom request£ Standard IC

Sample preparation£ Microwave digestion Berghof£ Réacteur de minéralisation sous-pression£ Distillateurs d’acides£ Distillateur d’HF

£ Hotblock from Environmental Express£ SysTubes from Environmental Express£ Disposable fillters from Environmental Express

AAS PHOTRON exclusive distribution in Switzerland

£ Hollow cathode lamps£ Super lamps£ Deuterium Lamps£ Graphite tube

ICP Glass Expansion Official Distributor£ Torch£ Nebulizor (concentric, V-Groove.)£ Chambers (Cyclonic, HF)£ Cones Spectron

MERCURY Analyzer Distributor ALTEC Switzerland

£ AMA 254 mercury analyzer on liquids and solids withoutdigestion

TEFLON - PFA LabwareSAVILLEX Distributor£ Vials, jars£ Tubes, digestion tubes£ Digestion vessels£ Syringe. Filtration

Precious MetalBIRMINGHAM METAL Distributor£ Boat crucible£ Electrodes£ Crucibles, molds for FluoX

Page 5: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

5

CHNOSN2 / ProteinesExclusive SÄNTIS

£ Capsules and boats (tin, silver.. )£ Copper oxide and reduced£ Catalyst£ Standards£ Quartz, metallic, ceramic tubes

Mitsubishi / Dia Instruments Analyser for:

£ N tot£ Sulfur£ Chlorine£ TOC£ Karl Fischer Humidity analyzer, microcoulometry£ Sample processor for Ion Chromatography£ KF reagents and references

Page 6: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

6

GGEENNEERRAALLEE PPRREESSEENNTTAATTIIOONN

TecDev is proud to be design as a Glass Expansion official dealer. We are very pleased to offer youthis catalogue dedicated to your ICP model. As is consistent with our ongoing commitment toprovide the highest level of customer support possible, this catalogue is intended to help simplifyyour task of selecting sample introduction components that are most suitable to your ICP-OES andICP-MS applications. Except items specified in catalogue all products are from Glass Expansion.

Glass Expansion catalogue represents the widest range of sample introduction components for ICPemission and mass spectrometers. Today, Glass Expansion support both new and old instrumentsfor 13 different manufacturers, representing sample introduction systems for over 50 different ICP-OES and ICP-MS models.The combination of listening to customers and innovative thinking has seen Glass Expansionsuccessfully overcome many of the commonly encountered application issues even with thetoughest samples. Innovative new designs include the high sensitivity SeaSpray nebulizer, the lowuptake MicroMist nebulizers, the high throughput Cinnabar mini-cyclonic spray chamber and themost recent Hydra-Trace kit that offers outstanding Hg detection on limited sample volumes.

Our quality, attention to detail and customer focus has not only attracted the attention of worldrenowned experts with their publications, but also resulted in Glass Expansion establishing itself asa major OEM supplier to the ICP manufacturers.As always, we rely on your feedback. If you wish to provide any input on how we can improve thiscatalogue or our products and services, please feel free to contact us.

TecDevLe VillaretCH - 1432 Belmont s/ Yverdon / SwitzerlandPhone +41 (24) 435 22 02Fax : +41 (24) 435 22 03Email : [email protected]

Page 7: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

7

§§ UHHOOWW TTOO OORRDDEERR && PPAAYYMMEENNTT TTEERRMMSS

For your convenience, you can place an order in any of the following ways:

Head OfficeBy Fax: +41 (24) 435 22 03By Email: [email protected] Mail: Address To:

TecDevLe VillaretCH 1432 Belmont s/ YverdonSwitzerland

Don’t forget to include your order number along with the part numbers of the products you want to purchase.Payment terms are strictly within 30 days from the date of invoice. We accept wire transfers and/or creditcards (Visa Card)For first order we request a pre-payment.

§§ UDDEELLIIVVEERRYY TTEERRMMSS

Delivery is typically within 2-3 weeks of order receipt. We do keep a large number of items in stock so deliveryis usually faster. We use Priority Air-mails for Europe but you can request another International Courierservice. However, if you have a preference for a different courier service, please advise us at the time youplace the order. The courier service will be charged to the person receiving the goods.

§§ UGGUUAARRAANNTTEEEEDD MMOONNEEYY BBAACCKK PPEERRFFOORRMMAANNCCEE OOFFFFEERR

If you are not satisfied with any of our products, simply return the goods to us within 14 days and you will befully reimbursed.

§§ UTTOORRCCHH RREEPPAAIIRR SSEERRVVIICCEE

Damaged torch could be repaired. It isparticularly the case when external tube isdamage. You just have to return the torch tous. We will return to manufacturer forevaluation. If the torch can be repaired, workwill be done and we will let you inform aboutcost. In case cost evaluation is too importantcompared to a new one, you will beinformed. Performance of repaired torch isRepair delay are never warranty so becareful to avoid your stock discontinuity.

§§ UTTRRAADDEEMMAARRKKSS

Glass Expansion Pty Ltd has rights to the following trademarks:Conikal, PolyCon, SeaSpray, MicroMist, VeeSpray, Cinnabar, Glass Expansion and the Glass ExpansionLogo.Viton and Teflon are registered trademarks of E.I. duPont de Nemours & Co., Inc.All company names listed are registered trademarks of their respective owners.

Page 8: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

8

WWHHYY CCHHOOOOSSEE GGLLAASSSS EEXXPPAANNSSIIOONN PPRROODDUUCCTTSS??

TecDev recommend and distribute Glass Expansion (GE) products for Quality, Reliability and Innovation

Glass Expansion has been manufacturing sample introduction components for ICP optical emission and massspectrometers since the early 1980s. Today we support both new and old instruments for 16 differentmanufacturers, representing sample introduction systems for over 50 different ICP-OES and ICP-MS models.Glass Expansion products are endorsed and supplied as standard products by major ICP manufacturers. Ourproducts are widely used and embraced by recognised analysts in the ICP industry, and have come to berecognised as 'industry standard' products. Glass Expansion's ability and expertise in manufacturing not onlyhigh quality nebulizers, but also spray chambers, torches and other ICP componentry, means that weunderstand the relationships between these products intimately. This often enables us to offer customers acomplete solution to their ICP sample introduction needs.

We believe that quality by design; production and service are paramount in product quality. Most vital is thequality of our designs. One can have the best methods of production and the highest quality finish, but if thedesign is not of the highest possible quality, then the product has not reached its full potential. Ourcommitment to R & D and product development has enabled us to produce innovative design solutions...

1. Did you know that Glass Expansion was the first company to introduce the 'Tracey' cyclonic spray chamber,which has since revolutionized the design and manufacture of cyclonic style spray chambers? That's right,before the advent of the cyclonic spray chambers, Scott style spray chambers were the norm. The design ofour cyclonic spray chambers helped analysts to achieve sensitivity gains, reduced washout times and matrixeffects that were not possible before.

2. Our fully demountable torches, with all components being removable and replaceable, are also an industryfirst. They've helped to make operating and using torches more efficient and cost effective. A great feature ofthis torch is that any of the 3 individual tubes can be replaced whilst maintaining accurate alignment andconcentricity. All replacement components are so precisely manufactured that no further optimization isrequired once a tube has been replaced. Changing torch tubes is so quick and easy, reducing down time andincreasing instrument productivity.

3. How many other nebulizer manufacturers do you know who manufacture nebulizers to operate optimally atthe gas pressures and flows specified by the ICP instrument manufacturer? Instead of manufacturingnebulizers which operate within a certain gas pressure and flow range, we go the extra distance in our strivefor quality... We manufacture our nebulizers according to your ICP specifications because we understand howcritical these specifications can be. We also understand that your time is important and that you shouldn'thave to waste it on recalibrating your instrument each time you change your nebulizer.

Reproducibility of analytical results in ICP analyses is of paramount importance. In an environment where asmall change or inconsistency in a product or variable can result in a dramatic change in analytical results,design quality and reliability is essential. Glass Expansion has developed unique and proprietarymanufacturing methods which have resulted in the production of components of high mechanical strength andmicron-level dimensional accuracy to satisfy the narrowest of analytical specifications, each and every time.Our products are recognized world wide for their excellent precision, cost effectiveness and reproducibility ofresults. This reproducibility is manifested in 3 ways:

• Short-term background and RSD's are lower• Long-term drift is lower• Analytical result spread, measured for successive test batches of Glass Expansion components, is

narrower.

Our design and manufacturing processes ensures reliability in the performance of our products, which helpsyou minimize variables which can affect your analyses. Glass Expansion's success has been built on afoundation of empathy towards our customers and their needs. Customer needs are the crux of our productdesign quality, reliability and innovation. Our recent responses to customers needs have lead to thedevelopment of user friendly solutions such as our quick connect EzyFit and EzyLok fittings for nebulizers,GazFit connectors for torches, and EzyLok fittings for jacketed spray chamber coolant hoses. We prideourselves on being attentive to our customers' needs..

Page 9: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

9

§§ UQQUUAALLIITTYY BBYY DDEESSIIGGNNUniformity is paramount

Using advanced manufacturing technology and the most stringent quality control systems, the GlassExpansion range of nebulizers, spray chambers and torches have set new standards answering the analyticalneeds for long-term performance and reliability covering a diverse range of ICP and ICP-MS applications.

Pneumatic nebulizers that are used for liquid samples, by far the most common type, produce a spray of liquidparticles with a wide range of sizes - a 'poly disperse' spray. The size distribution of this spray is governedintimately by the geometry of the region of gas-sample interaction. If this region deviates from its intendedannular or circular shape, whether by manufacturing variability, mechanical resonances, surface modificationssuch as erosion or by dimensional changes with age processes, the size distribution of the spray will alter andwith it the ICP analytical results. Glass Expansion's designers have made a direct attack on the 'Achilles-Heel'problem of sample introduction (1) by devising components generally - and nebulizers in particular - thatfollow the first law of manufacturing - that everything produced should always be exactly the same. Systematiccontrol at every stage of our production process guarantees that you always get the same high qualityproduct.

For nebulizers, this requires designs with high mechanical strength, micron-level dimensional accuracy oforifices and surface finishes that are repeatable. For concentric glass nebulizers in particular, this means thatheat treatments of the glass have been kept to a minimum and that the central capillaries are shaped at lowtemperatures. This unique approach by Glass Expansion's designers result in nebulizers that:

1. Give the same analytical results, to within a standard deviation of 1%, for a statisticallysignificant test batch of nebulizers and where the test instrument drift can be shown to benegligible within the same test period, and

2. Enable ICP's to achieve 'Rank-5' short term and long term background RSD's, by testsoutlined by Mermet and Poussel in their 1995 review of ICP figures of Merit (2) These'Rank-5' figures represent best ICP performance figures that are being achieved in themarket place of the new century. When Glass Expansion nebulizers are used, RSDvalues of 0.5% or higher are indicative of instabilities from other sources - whether theybe badly adjusted sample pumps, torch RF power instability or simply the photon noise oflight-limited spectrometers.

(1) R.F. Browner and A.W. Boorn, Sample Introduction: the Achilles ‘ heel of Atomic Spectroscopy, AnalyticalChemistry, Vol. 56, pp. 787A-798A (1984)

(2) J.M. Mermet and E. Poussel, ICP Emission Spectrometers: 1995 Analytical Figures of Merit, AppliedSpectroscopy, Vol. 49, No. 10, pp 12A-18A (1995): see Table V.

Page 10: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

10

NNEEBBUULLIIZZEERRSS

§§ UHHOOWW TTOO CCHHOOOOSSEE TTHHEE MMOOSSTT SSUUIITTAABBLLEE NNEEBBUULLIIZZEERR FFOORR YYOOUURR AAPPPPLLIICCAATTIIOONN

§§ UGGLLAASSSS EEXXPPAANNSSIIOONN NNEEBBUULLIIZZEERR DDEESSIIGGNNAATTIIOONNSS......WWHHAATT DDOO TTHHEEYY AALLLL MMEEAANN??

ARxx-yy-ZZnnnE

AR argon gas operated nebulizerxx the nominal argon pressure in psigyy the argon flow at nominal pressure, in L/min eg. 07=0.7L/minZZ nebulizer model type:

FC = Conikal nebulizer fitted with EzyFitFS = Slurry nebulizer fitted with EzyFitFSS = SeaSpray nebulizer fitted with EzyFitFM = MicroMist nebulizer fitted with EzyFitQV = Quartz VeeSpray v-groove nebulizerCV = Ceramic VeeSpray v-groove nebulizerCP = PolyCon Polyimide HF resistant nebulizerPFA = OpalMist PFA HF resistant nebulizer

nnn Aspirated uptake at nominal pressure, in ml/mineg. FC3 = 3ml/min, FM04 = 0.4ml/min, CP005 = 0.05ml/min

E Letter "E" indicates that the nebulizer is supplied with theEzyLok argon connector.

§ U

Page 11: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

11

NNEEBBUULLIIZZEERRSS FFOORR AAQQUUEEOOUUSS AANNDD OORRGGAANNIICCSS AANNAALLYYSSEESS

SeaSpray - the high dissolved solids nebulizerThe SeaSpray concentric nebulizer offers outstanding nebulization efficiency for trace level analyses. It offers freedomfrom clogging while nebulizing solutions to the limit of solubility of most mineral salts, and conferring significant sensitivitygains.

• Material: Borosilicate glass• High physical reproducibility ~ 1%• TDS tolerance, typically up to 20%• High tolerance to particulates, typically up to 75um• Low RSD's due to highly accurate construction• Standard available uptake: 2ml/min. 1ml/min uptake available on request.

All SeaSpray nebulizers listed in this website are supplied with:1 x EZT-075 EzyFit connector (sample tube 0.75mm ID x 1.3mm OD)1 x SNP-1 Nebulizer Hose Clip (1 clip)

MicroMist - the low uptake nebulizer for all ICPsThe MicroMist micro-uptake glass concentric nebulizer offers high performance for limited sample volumes. It makesroutine ICP-MS Hg determinations possible and reduces matrix effects when used with Glass Expansion's Cinnabar spraychamber.

• Material: Borosilicate glass• High physical reproducibility ~ 1%• TDS tolerance, typically up to 15%• Low RSD's due to highly accurate construction• Standard available uptake: 0.05, 0.1, 0.2, 0.4 & 0.6ml/min

All MicroMist nebulizers listed in this website are supplied with:1 x SNP-1 Nebulizer Hose Clip (1 clip)MicroMists with sample uptakes 0.2 - 0.6ml/min are fitted with:an EzyFit connector with 1.3mm OD x 0.50mm ID x 700mm long sample tubing.MicroMists with sample uptakes 0.05 - 0.1ml/min are fitted with:an EzyFit connector with 1.3mm OD x 0.25mm ID x 700mm long sample tubing.

ConiKal - an industry standardThe Conikal concentric nebulizer gives the most reproducible results for standard ICP analyses. It represents the choicenebulizer for high precision, routine aqueous and organic applications.

• Material: Borosilicate glass• High physical reproducibility ~ 1%• TDS tolerance, typically up to 5%• High tolerance to particulates, typically up to 75um• Low RSD's due to highly accurate construction• Standard available uptake: 1, 2 & 3ml/min

All Conikal nebulizers listed in this website are supplied with:1 x EZT-075 EzyFit connector (sample tube 0.75mm ID x 1.3mm OD)1 x SNP-1 Nebulizer Hose Clip (1 clip)

Slurry - for slurries or suspensionsThe Slurry glass concentric nebulizer is ideal for specialized applications requiring the aspiration of slurries orsuspensions. It's capillary bore is 50% larger than standard concentric which reduces the possibility of particle blockage,while giving excellent signal stability.

• Material: Borosilicate glass• High physical reproducibility ~ 1%• TDS tolerance, typically ~ 1%• High tolerance to particulates, typically up to 150um• Low RSD's due to highly accurate construction• Slurry nebulizers have a natural liquid uptake of 6ml/min but operates

best between 1.5 - 2.5ml/minAll Slurry nebulizers listed in this website are supplied with:1 x EZT-075 EzyFit connector (sample tube 0.75mm ID x 1.3mm OD) 1x SNP-1 Nebulizer Hose Clip (1 clip)

Eg. AR30-1-FM02EMicroMist Nebulizer withEzyFit Sample Connector andEzyLok side arm

Eg. AR30-1-FSS2E SeaSprayNebulizer with EzyFit SampleConnector and EzyLok side arm

Page 12: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

12

Quartz VeeSpray - handles high particle and TDS loads bestThis VeeSpray nebulizer is made from quartz. It provides reproducible performance when working with samplescontaining large particulates. It has the same 6mm diameter as the standard concentric nebulizer.

• Material: Quartz• High physical reproducibility ~ 1%• TDS tolerance, typically up to 30%• High tolerance to particulates, typically up to 300um• Must be pumped - does not self aspirate• Design uptake range: 0.6 - 3ml/min. Operates best between 1.5 - 2.5ml/min

All VeeSpray nebulizers listed in this website are supplied with:700mm length of VSS-075, VeeSpray sample tubing (sample tube 0.75mm ID x 1.3mm OD)1 x SNP-1 Nebulizer Hose Clip (1 clip)

The EzyFit ConnectorGlass Expansion developed the EzyFit connector to offer a no-fuss method of connecting sample uptake tubes tonebulizer. EzyFit connectors are simple to use, reduce washout times, and eliminate dead volume. The connector issupplied in packs of 10 and comes with sample tubes of 3 commonly required internal diameters:

EZT-025 EzyFit Connector 0.25mm ID x 1.3mm OD x 700mm longEZT-050 EzyFit Connector 0.50mm ID x 1.3mm OD x 700mm longEZT-075 EzyFit Connector 0.75mm ID x 1.3mm OD x 700mm long

TEzyFit connectors are made to be used only with Glass Expansion glass concentric nebulizers that have the letter 'F' intheir designation (eg. AR30-07-FSS2E), because these nebulizers are made with a sample inlet tube that hNebulizerssuch as the AR30-1-C1E Conikal, the AR30-1-S6E Slurry nebulizer and the AR30-1-SS2E SeaSpray would therefore notbe compatible with EzyFit connectors. The user would be required to make his/her own sample tube connection for usewith these 'standard connection' nebulizers. as a very precise bore.

Notes on Nebulizer UptakeWhen a Glass Expansion nebulizer is designed for a specified uptake by aspiration, the nebulizers best short-term stabilitywill always be obtained at an uptake close to that 'design aspiration level'. Thus for a 'PFA04' OpalMist or an 'FM04'MicroMist, they will be best used at an uptake between ~0.3ml/min and ~0.6ml/min. The reasons for this are found in thefundamental properties of liquid dispersion from narrow capillaries under the action of turbulent gas jets.

Another point to note is that it would also be difficult to 'force' a nebulizer to a higher uptake by pumping, since pumppressures required would rapidly rise to very high levels. Thus while an AR30-1-CV6 'VeeSpray' nebulizer could bepumped to an uptake of 6ml/min, it would be impractical to try the same pumped uptake rate with an AR30-1-FM02'MicroMist'...indeed, it might burst the pump tube connections. The laws governing liquid flows indicate that there is a 4thpower relationship between applied pressure and the diameter of a tube through which a liquid is pumped by thatpressure.

Unfortunately in one way, there is a law of diminishing returns (for sensitivity) that applies as the uptake of a nebulizer isincreased: this means that uptake (and of course pressure in the pumped sample tubes) can often be lowered withoutlosing much sensitivity - particularly if the volume of the spray chamber is small. Such an uptake reduction can be madeby simply reducing the internal diameter (ID) of peristaltic pump tube. Reducing the ID by a factor of 2 will reduce theuptake by a factor of 4, and thus the pressure in the tube by more than 10, if the pump roller speed is unchanged

Page 13: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

13

§§ UNNEEBBUULLIIZZEERR FFOORR HHFF

PolyCon - for routine high precision HF analysesThe PolyCon concentric nebulizer represents the choice nebulizer for high precision analyses involving samples digestedin HF. The PolyCon has been used successfully in ICP de-solvators such as the MCN-6000, where high temperatures areencountered. It has become a favorite in the semi conductor industry, and has enabled analysts to produce accurate (r =0.9998) calibration curves for low-ppt levels of Na, K, Fe and Ca in 30% hydrogen peroxide.

• Material: HF Resistant Polyimide• High physical reproducibility ~ 2%• High tolerance to particulates, up to 75um depending on uptake• TDS tolerance, typically ~5%• Low RSD's due to concentric geometry• Uses only standard ICP argon supply pressures• Standard 6mm size fits standard cyclonic spray chambers. Adaptors are available for Scott type spray chambers• Standard available uptakes: 0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 2 & 5ml/min for samples with large particulates

All PolyCon nebulizers listed in this website are supplied with:1 x SNP-1 Nebulizer Hose Clip (1 clip)PolyCons with sample uptakes 0.05 - 0.1ml/min are supplied with 1.3mm OD x 0.25mm ID x 700mm long sample tubing.PolyCons with sample uptakes 0.2 - 0.8ml/min are supplied with 1.3mm OD x 0.50mm ID x 700mm long sample tubing.PolyCons with sample uptakes 2 - 5ml/min are supplied with 1.3mm OD x 0.75mm ID x 700mm long sample tubing.

OpalMist - ideal for the geochemistry & semiconductor industryThe OpalMist PFA concentric nebulizer represents the choice nebulizer for high precision analyses involving analysesrequiring high chemical resistance to HF, alkalis and organics. It also provides excellent results for trace analyses.

• Material: PFA• High physical reproducibility ~ 3%• Strong and consistent self-aspiration• High tolerance to particulates, up to 75um depending on uptake• TDS tolerance, typically up to 30%• Low RSD's due to concentric geometry• Uses only standard ICP argon supply pressures• Standard 6mm size fits standard cyclonic spray chambers. Adaptors are available for Scott type spray chambers• Standard available uptakes: 0.05, 0.1, 0.2, 0.4, 0.6 & 2ml/min

All OpalMist nebulizers listed in this website are supplied with:1 x SNP-1 Nebulizer Hose Clip (1 clip)OpalMists with sample uptakes 0.05 - 0.1ml/min are supplied with 1.3mm OD x 0.25mm ID x 700mm long sample tubing.OpalMists with sample uptakes 0.2 - 0.8ml/min are supplied with 1.3mm OD x 0.50mm ID x 700mm long sample tubing.OpalMists with sample uptakes 2 - 5ml/min are supplied with 1.3mm OD x 0.75mm ID x 700mm long sample tubing

Ceramic VeeSpray - handles high particle and TDS loads bestThe Ceramic VeeSpray nebulizer is made from alumina ceramic, making it ideal for HF analyses. It provides reproducibleperformance when working with samples containing large particulates. It has the same 6mm diameter as the standardconcentric and the Alumina material makes it the most robust and abrasion resistant ICP nebulizer.

• Material: 99.8% Alumina Ceramic• High physical reproducibility ~ 1%• TDS tolerance, typically up to 30%• High tolerance to particulates, typically up to 300um• Must be pumped - does not self aspirate• Design uptake range: 0.6 - 3ml/min. Operates best between 1.5 - 2.5ml/min

All Ceramic VeeSpray nebulizers listed in this website are supplied with:700mm length of VSS-075, VeeSpray sample tubing (sample tube 0.75mm ID x 1.3mm OD)1 x SNP-1 Nebulizer Hose Clip (1 clip)

Page 14: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

14

Glass Expansion Eluo to clean your nebulizerNNEEWW EELLUUOO :: FFOORR NNEEBBUULLIIZZEERR CCLLEEAANNIINNGG T

The Eluo is available for Glass Expansion concentric glass and HF-resistant nebulizers.

Cleaning your nebulizer is as easy as 1, 2, 3.1. Fill your Eluo with Methanol.2. Insert your nebulizer; tip first, into the Eluo.3. Clean your nebulizer by pressing the Plunger down.

Particle build-up in a nebulizer capillary and tip causes sample flow to be constricted, thereby reducingnebulizer efficiency and performance. Previously there was no simple way to effectively clean and unblocknebulizers. Now, blocked nebulizers can be safely and easily restored to optimum performance with arevolutionary new cleaning instrument - the Eluo.The Eluo is designed to efficiently deliver a cleanser through the nebulizer capillary to dislodge particle build-up and thoroughly clean the nebulizer. One simple action does it all. No more messy procedures, waitingovernight or shattered nebulizers in ultrasonic baths.Use the Eluo regularly to maintain nebulizer performance and prolong nebulizer life. The answer to cleaningyour nebulizers is so simple, every lab should have one - the Eluo.

Finally, a worry frees ICP Argon Humidifier.NNEEWW CCAAPPRRIICCOORRNN :: AARRGGOONN HHUUMMIIDDIIFFIIEERR

The Argon Humidifier is commonly used inICP analyses involving samples with highdissolved solids concentration. Helping toprevent salt build-up inside the sampleintroduction system, the Argon Humidifierallows uninterrupted and maintenance freeoperation. Glass Expansion is pleased tointroduce the Capricorn - Combining ease ofoperation, high performance and safety.

• The rugged and durable plasticcasing enhances safety.

• The built-in pressure indicatorserves as a diagnostic so youalways know the sampleintroduction system is operatingproperly.

• An optional easy-to-use bypasstoggle allows you to take theCapricorn off-line without disconnecting argon lines.

• Maximum and minimum fill marks ensure that you are always operating under optimum conditions.• A rugged bubbling frit ensures maximum saturation of the argon

Références DescriptionTU70-ELUOUT Eluo Nebulizer Cleaner (glass concentric nebulizers)TU70-ELUO-OPUT Eluo HF Nebulizer Cleaner (OpalMists & PolyCons)TU703-0070UT Eluo Plunger

TU703-0058UT Eluo Barrel

TU703-0069UT Eluo Nebulizer Holder (glass concentric nebulizers)

TU703-0074UT Eluo HF Nebulizer Holder (OpalMists & PolyCons)TU70-0806UT Eluo O-Ring Kit (2 sets)

Capricorn without bypass,P/N 70-808-1000 Capricorn with bypass, P/N

70-808-1226

Page 15: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

15

20-809-0276HE

SSPPRRAAYY CCHHAAMMBBEERRSS,, QQUUAALLIITTYY,, UUNNIIFFOORRMMIITTYY AANNDD EEFFFFIICCIIEENNCCYY

§§ UHHOOWW TTOO CCHHOOOOSSEE TTHHEE MMOOSSTT SSUUIITTAABBLLEE SSPPRRAAYY CCHHAAMMBBEERR FFOORR YYOOUURR AAPPPPLLIICCAATTIIOONN

§§ U TTRRAACCEEYY CCYYCCLLOONNIICC CCHHAAMMBBEERRSS

Tracey cyclonic - an industry standardThe Tracey cyclonic spray chamber is Glass Expansion's standard glass cyclonic spray chamber. It gives the bestsensitivity, reproducibility and lowest memory effects for standard ICP analyses.

• Material: Borosilicate glass• Volume: 50ml• High sensitivity and reduced matrix effects• Physical reproducibility ~1%• Active scouring of internal surfaces by sample• Faster washout than older coaxial chamber designs• Low RSD's due to highly accurate construction• Positive stop for reproducible nebulizer insertion• Application uptake range 0.2 to 3.0ml/min

Jacketed Tracey spray chamber (borosilicate glass material)The Jacketed Tracey spray chamber is made with an external jacket for theintroduction of coolant for temperature control. Thermostatting to constanttemperature helps ensure highly reproducible results and long term stability.Can also be cooled to suppress volatilization and allow the direct aspirationof highly volatile solvents such as naphtha and petrol/gasoline.

HF resistant Tracey spray chamberMade from HF resistant Polypropylene, the HF resistant Tracey is ideal for use with thePolyCon, OpalMist or Ceramic VeeSpray nebulizers

U

20-809-0224HE

20-809-0220

Page 16: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

16

20-809-0285HE

20-809-0313HE

TTWWIISSTTEERR CCYYCCLLOONNIICC CCHHAAMMBBEERRSS

Twister cyclonic - reduces solvent loadThe Twister cyclonic spray chamber features a central transfer tube which acts as a secondary particle separator helpingseparate larger aerosol particles from the sample. This reduces solvent load inthe plasma without compromising detection limits.

• Material: Borosilicate glass• Volume: 50ml• Physical reproducibility ~1%• Low RSD's - highly accurate construction similar to Tracey cyclonic,

except with central transfer tube• Application uptake range 0.2 to 3.0ml/min

Jacketed Twister spray chamber (borosilicate glass material)The Jacketed Twister spray chamber is made with an external jacket for theintroduction of coolant for temperature control. Thermostatting to constanttemperature helps ensure highly reproducible results and long term stability.Can also be cooled, to suppress volatilization, allowing the direct aspiration ofhighly volatile solvents such as naphtha and petrol/gasoline. Recommendedfor analyses of organics samples.

§§ UCCIINNNNAABBAARR CCYYCCLLOONNIICC CCHHAAMMBBEERRSS

Cinnabar Cyclonic - the low volume spray chamber for all ICPsThe Cinnabar spray chamber is a mini-cyclonic spray chamber which gives goodsensitivity at very low uptakes. The Cinnabar's design and low volume is ideal forthe reduction of memory and matrix effects and very fast washout.

• Material: Borosilicate glass• Volume: 20ml• Physical reproducibility ~1%• Matrix effects 5 times lower than with coaxial chambers• Low RSD's due to highly accurate construction.• Positive stop for reproducible nebulizer insertion• Application uptake range ~20 to 600 microlitres/min• Ideal for use with MicroMist nebulizers

Jacketed Cinnabar spray chamber (borosilicate glass material)The Jacketed Cinnabar spray chamber is made with an external jacket forthe introduction of coolant for temperature control. Thermostatting toconstant temperature helps ensure highly reproducible results and long termstability. Can also be cooled to suppress volatilization and allow the directaspiration of highly volatile solvents such as naphtha and petrol/gasoline.Ideal for use with MicroMist nebulizers

HF resistant Cinnabar spray chamberMade from HF resistant Polypropylene, the HF resistant Cinnabar is ideal for usewith the low-uptake PolyCon and OpalMist nebulizers.

§§ UTTWWIINNNNAABBAARR CCYYCCLLOONNIICC CCHHAAMMBBEERRSSTwinnabar cyclonic - low volume, low solvent loadThe Twinnabar cyclonic spray chamber is a low volume spray chamber with acentral transfer tube (or baffle), combining the benefits of the Twister and theCinnabar. It combines excellent precision with a very fast washout.

• Material: Borosilicate glass• Volume: 20ml• Physical reproducibility ~1%• Low RSD's due to highly accurate construction• Application uptake range 0.2 to 3.0ml/min

20-809-0164HE

20-809-0207HE

20-809-0261HE

Page 17: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

17

Nebulizer adaptors for glass Tracey and Twisterspray chambers with O-ring sealAll glass Tracey and Twister spray chambers shown inthis website with an O-ring seal nebulizer adaptor, comestandard with nebulizer adaptor P/N 21-808-0256. Thisadaptor is suitable for use with 6mm glass concentricnebulizers. Nebulizer adaptor P/N 21-808-0257 isrequired when using these glass Tracey and Twisterspray chambers with VeeSpray, OpalMist and PolyCon nebulizers.

Nebulizer adaptors for glass Cinnabar and Twinnabar spray chambers with O-ring sealAll glass Cinnabar and Twinnabar spray chambersshown in this website with an O-ring seal nebulizeradaptor, come standard with nebulizer adaptor P/N21-808-0259. This adaptor is suitable for use with6mm glass concentric nebulizers. Nebulizer adaptorP/N 21-808-0944 is required when using this glassCinnabar and Twinnabar spray chambers withOpalMist and PolyCon nebulizers

Nebulizer adaptors for HF Tracey spray chambersAll HF Tracey spray chambers come standard with nebulizer adaptor P/N 21-808-0257. Thisadaptor is suitable for use with VeeSpray, OpalMist and PolyCon nebulizers. Nebulizeradaptor P/N 21-808-0256 is required when using HF Tracey spray chambers with 6mmglass concentric nebulizers.

Nebulizer adaptors for HF Cinnabar spray chambersAll HF Cinnabar spray chambers come standard with nebulizer adaptor P/N 21-808-0944.This adaptor is suitable for use with OpalMist and PolyCon nebulizers. Nebulizer adaptor P/N 21-808-0259 is requiredwhen using HF Cinnabar spray chambers with 6mm glass nebulizers.

The Helix - O-ring free nebulizer fittingMost ICP spectrometers rely on an O-ring seal between the nebulizer and the spray chamber. However, even the mostchemically resistant O-rings are prone to wear and tear and require regular replacement. They also tend to bond to aglass nebulizer, making the nebulizer difficult to remove. To eliminate these problems, Glass Expansion has developedHelix - the user friendly nebulizer fitting.

• No more tedious O-ring replacement• Totally inert interior surface• Smooth release/lock mechanism seals the chamber• Positive stop to ensure correct nebulizer position

Helix fittings can only be used with Glass Expansion spray chambersincorporating the Helix side arm. They cannot be used with spraychambers designed with on O-ring seal.

Part numbers for Helix spray chambers can be identified by the letters HE at the end, as in 20-809-0224HE.

The UniFit connectorFor your convenience and safety, each Glass Expansion spray chamber withstandard 4mm drain tube is supplied with a UniFit connector. The UniFit connectorefficiently connects a 0.75mm ID x 1.3mm OD drain tube to the spray chamber.To order spare UniFit connectors, order P/N UFT-075 for a pack of 3 connectors

Page 18: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

18

Glass Expansion RF Coils - represent the highestquality in design and manufacturing§§ UWWHHYY TTOO CCHHAANNGGEE YYOOUURR RRFF CCOOIILLSS

• Regular replacement of corroded coils reduces the load on the RF generating system• Changing corroded coils increases energy transfer, resulting in a more robust plasma and

generally higher analytical line intensities.

§§ UAADDVVAANNTTAAGGEE OOFF GGLLAASSSS EEXXPPAANNSSIIOONN RRFF CCOOIILLSS::

• High quality and consistent plating of our coils promotesextended coil life

• Each coil is supplied on a plastic former ensuring correctdimensions and easier installation

• Each coil is supplied in a special protective container to ensure correct dimensions aremaintained, and the coil arrives corrosion free

• Correct alignment of the coil with respect to the torch body reduces de vitrification of theouter tube

• Reusable alignment tools ensure correct installation every time. Our CD with Do-It-Yourselfinstructions saves time

For more information see end of catalogues

Glass Expansion O-ring Free Nebulizer FittingNNEEWW HHEELLIIXX:: OO RRIINNGG FFRREEEE NNEEBBUULLIIZZEERR FFIITTTTIINNGG!!

Most ICP spectrometers rely on an O-ring seal between the nebulizer and the spray chamber. However, eventhe most chemically resistant O-ring are prone to wear and tear and require regular replacement. They alsotend to bond to a glass nebulizer, making the nebulizer difficult to remove. To eliminate these problems, GlassExpansion has developed Helix - the user friendly nebulizer fitting.

• No more tedious O-ring replacement• Totally inert interior surface• Smooth release/lock mechanism seals the chamber• Positive stop to ensure correct nebulizer position

Helix fittings can only be used with Glass Expansion spraychambers incorporating the Helix side arm. They cannot be usedwith spray chambers designed with on O-ring seal.

Part numbers for Helix spray chambers can be identified by theletters HE at the end, as in 20-809-0224HE.

Page 19: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

19

VVAARRIIAANN LLIIBBEERRTTYY SSEERRIIEESS 110000//220000//112200//115500//222200 AANNDD VVIISSTTAA ––RRAADDIIAALL

§§ UTTOORRCCHHSS

Réf RéfVARIAN Désignation TORCHE MONO BLOC

800-05 20-100696-9020-100696-00

Varian Radial Quartz Torch-Low Flow 1.5mmInjector, 6mm OD side arms

800-05B 20-10069600B Torch ICP-ES with ball joint

800-05W Torch ICP-ES « wears metals”

800-08 2010076400 Torch ICP-ES « Extended » for nitrogendetermination

800-12 2010090400 Torch Vista 90 degree bend

800-13 2010080500 ICP modified torch800-75 Torch high solids ICP-ES

RéfPRECISION

RéfVARIAN Designation TORCHE DEMONTABLE

CLASSIQUE

800-50 99-100568-00 Torch inert, dismountable including the main part,the alumina tube and the Teflon support

800-10 20-100729-90 Torch, HF dismountable ICP-ES Body only

800-45 24-100675-00 Alumina injector 1.8800-46 N/A Alumina injector 2.5

800-41 20-100730-00 Quartz injector 1.8

800-42 20-100775-00 Quartz injector 0.8

800-48 99-100573-00 PTFE injector holder

800-25 2010070790 Torche «bonnet»

Ref TORCHES DEMONTABLES GLASSEXPANSION

Torch Quartz Semi-dismountable complete in quartz

T30-808-0541T Quartz torch body Semi dismountableT31-808-0381T Semi-DMT Torch Adaptor 8/44T31-808-0543T Tapered Quartz Injector 1.5mmT31-800-0003T Varian Radial Quartz Torch BonnetTGAZ-06T GazFit Connectors (Pkt.4) - for 6mm OD side arm

T31-100-0105T

Extractor Tool for Semi Demountable Torch,15.2mm (Varian)

T31-808-0544T Tapered Quartz Injector 1.0mmT31-808-0543T Tapered Quartz Injector 1.5mmT31-808-0545T Tapered Quartz Injector 1.8mm

TU30-808-0542UT

T31-808-0400T Tapered Quartz Injector 2.4mmT30-808-0541T Quartz torch body Semi dismountableT30-808-0942T

T31-808-0381T Semi-DMT Torch Adaptor 8/44

Page 20: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

20

T31-808-0938T Tapered Alumina Injector 1.8mmT31-800-0003T Varian Radial Quartz Torch BonnetTGAZ-06T GazFit Connectors (Pkt.4) - for 6mm OD side armT31-100-0105T Extractor Tool for Semi Demountable Torch,

15.2mm (Varian)

T30-808-0541T Quartz torch body Semi dismountable

T31-808-0381T Torch Adapter 8/44

T31-800-0003T Torch « bonnet » in quartz GE

§§ SSPPRRAAYY CCHHAAMMBBEERR WWIITTHH OO--RRIINNGG

Ref Designation Spray Chamber

800-22 Spray Chamber for MLN nebulizer( modified Lichte) (See description atend of catalogue)

Chambre GLASSEXPANSION

If you prefer systems without seals please check the Helix model

T20-809-0600T

VARIAN ref20-100817-00

Tracey cyclonic - an industry standardTracey Spray Chamber is a 50ml cyclonic spray chamber which hasexcellent stability with low memory and matrix effects.Note: For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0183T

Cinnabar Cyclonic - the low volume spray chamber 20mlThe Cinnabar spray chamber gives good sensitivity at very low uptakes,while reducing memory and matrix effects. Designed for use with GlassExpansion's MicroMist nebulizersNote: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0285T

Twister cyclonic - reduces solvent load 50mlThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 Tis suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is requiredwhen using this spray chamber with VeeSpray, OpalMist and PolyConnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0448T

Twinnabar cyclonic - low volume, low solvent load – 20mlThe Twinnabar cyclonic spray chamber is a low volume spray chamberwith a central transfer tube (or baffle), combining the benefits of theTwister and the Cinnabar. It combines excellent precision with a very fastwashout.Note: Nebulizer adaptor T21-808-0259 T Is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0129T

Jacketed Tracey spray chamber (borosilicate glass material) 50mlThe Tracey spray chamber has excellent sensitivity and stability with lowmemory and matrix effects. Can be thermostated to constant temperatureto ensure highly reproducible results. Alternatively can be cooled tosuppress volatilization, allowing the direct aspiration of highly volatilesolvents such as naphtha and petrol/gasolineNote: For your convenience includes TUFT-075 T UniFit Connector (1 unit)and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4(suitable for jacketed spray chambers)

Page 21: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

21

T20-809-0207T

Jacketed Cinnabar spray chamber (borosilicate glass material) 20mlThe Jacketed Cinnabar cyclonic spray chamber can be thermostated toconstant temperature to ensure highly reproducible results. Can also becooled to suppress volatilization, allowing the direct aspiration of highlyvolatile solvents such as naphtha and petrol/gasoline.Note:- Nebulizer adaptor T21-808-0259 T Is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit) andTQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitable forjacketed spray chambers)

T20-809-0366T

Twister cyclonic - reduces solvent load 50 mlCharacteristics identical to 20-809-0285.The Jacketed Twister cyclonic spray chamber can be thermostated toconstant temperature to ensure highly reproducible results. Can also becooled to suppress volatilization, allowing the direct aspiration of highlyvolatile solvents such as naphtha and petrol/gasoline.Note:- For your convenience includes TUFT-075 T UniFit Connector (1 unit)and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitablefor jacketed spray chambers)

T21-808-0553T

Varian V groove Nebulizer Adaptor - for Traceys & Twisters, Required foruse with Varian designed V groove type nebulizers

T20-808-0521T

HF resistant Tracey spray chamber 50mlThe HF resistant Tracey spray chamber has excellent sensitivity with lowmemory and matrix effects. It is designed for use with Glass Expansion'sPolyCon nebulizersNote:- Nebulizer adaptor T21-808-0257 T is suitable for use with VeeSpray,OpalMist and PolyCon nebulizers. Nebulizer adaptor P/N T21-808-0256 T isrequired when using this spray chamber with 6mm glass concentricnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

§§ SSPPRRAAYY CCHHAAMMBBEERR WWIITTHHOOUUTT OO RRIINNGG «« HHEELLIIXX SSYYSSTTEEMM »»

Most ICP spectrometers rely on an O-ring seal between the nebulizer and the spray chamber. However, eventhe most chemically resistant O-ring is prone to wear and tear and requires regular replacement. They alsotend to bond to a glass nebulizer, making the nebulizer difficult to remove. To eliminate these problems, GlassExpansion has developed Helix - the user friendly nebulizer fitting.

RefDesignation

Spray chamber

T20-809-0600HET

Tracey cyclonic - an industry standard - 50mlTracey Spray Chamber is a 50ml cyclonic spray chamber which hasexcellent stability with low memory and matrix effects.Note: For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0183HET

Cinnabar Cyclonic - the low volume spray chamber - 20mlThe Cinnabar spray chamber gives good sensitivity at very low uptakes,while reducing memory and matrix effects. Designed for use with GlassExpansion's MicroMist nebulizersNote: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

Page 22: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

22

T20-809-0285HET

Twister cyclonic - reduces solvent load 50mlThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is requiredwhen using this spray chamber with VeeSpray, OpalMist and PolyConnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0448HET

Twinnabar cyclonic - low volume, low solvent load - 20mlThe Twinnabar cyclonic spray chamber is a low volume spray chamberwith a central transfer tube (or baffle), combining the benefits of theTwister and the Cinnabar. It combines excellent precision with a very fastwashout.Note: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0129HET

Twister cyclonic - reduces solvent load - 50mlThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is requiredwhen using this spray chamber with VeeSpray, OpalMist and PolyConnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0207HET

Jacketed Tracey spray chamber (borosilicate glass material) - 50mlThe Tracey spray chamber has excellent sensitivity and stability with lowmemory and matrix effects. Can be thermostated to constant temperatureto ensure highly reproducible results. Alternatively can be cooled tosuppress volatilization, allowing the direct aspiration of highly volatilesolvents such as naphtha and petrol/gasolineNote: For your convenience includes TUFT-075 T UniFit Connector (1 unit)and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitablefor jacketed spray chambers)

T20-809-0366HET

Twister cyclonic - reduces solvent load - 50 mlCharacteristics identical to 20-809-0285.The Jacketed Twister cyclonic spray chamber can be thermostated toconstant temperature to ensure highly reproducible results. Can also becooled to suppress volatilization, allowing the direct aspiration of highlyvolatile solvents such as naphtha and petrol/gasoline.Note:- For your convenience includes TUFT-075 T UniFit Connector (1 unit)and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitablefor jacketed spray chambers)

T70-100-0152T Helix Locking Screw

T70-100-0237T Helix Seal

Page 23: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

23

§§ NNEEBBUULLIIZZEERRSS

CONICAL - AN INDUSTRY STANDARDGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)Suggested Operation: 30 0.7 2

AR30-07-FC3Equivalent OEMRef 2010081600

The Conical concentric nebulizer gives the most reproducible results forstandard ICP analyses. It represents the choice nebulizer for high precision,routine aqueous and organic applications. High tolerance to particulates,typically up to 75um. TDS tolerance, typically up to 5%Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-07-FC3ET

Equivalent OEMRef 2010081600

Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x1.3mm OD x 700mm L tubing (1 unit)- Includes TEL-1 T EzyLok Connector Kit- This nebulizer supersedes AR30-07-FC3

SEASPRAY - THE HIGH DISSOLVED SOLIDS NEBULIZERGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)Suggested Operation: 30 0.7 2

AR30-07-FSS2Equivalent OEM ref 2010096400

The SeaSpray concentric nebulizer offers outstanding nebulization efficiencyfor trace level analyses. It offers freedom from clogging while nebulizingsolutions to the limit of solubility of most mineral salts (up to 20%), andconferring significant sensitivity gains. Accept particles up to 75µm- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-07-FSS2ET

Equivalent OEM ref 2010096400

IdemNote:- Includes TEL-1 T EzyLok Connector Kit- This nebulizer supersedes AR30-07-FC3

SLURRY - FOR SLURRIES OR SUSPENSIONSGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)

Suggested Operation:30 0.7 6

AR30-07-FS6 The Slurry glass concentric nebulizer is ideal for specialized applicationsrequiring the aspiration of slurries or suspensions. It's capillary bore is 50%larger than standard concentric which reduces the possibility of particleblockage, while giving excellent signal stability. High tolerance to particulates,typically up to 150um. Slurry nebulizers have a natural liquid uptake of6ml/min but operates best between 1.5 - 2.5ml/min- Includes TEZT-075 TEzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing (1unit)

TAR30-07-FM06ET Note:- Includes TEZT-075 TEzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing (1unit)- Includes TEL-1 TEzyLok Connector Kit- Operates best between 1.5 - 2.5ml/min. This nebulizer supersedes AR27-075-FS6

VEESPRAY - HANDLES HIGH PARTICLE AND TDS LOADS BESTGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)

30 0.7 6

Page 24: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

24

TAR30-07-QV6T

(Quartz)Non-aspirating.

This VeeSpray nebulizer is made from quartz. It provides reproducibleperformance when working with samples containing large particulates. It hasthe same 6mm diameter as the standard concentric nebulizer. TDS tolerance,typically up to 30%. High tolerance to particulates, typically up to 300umNote:- Includes TVSS-075 T VeeSpray Nebulizer Sample Tubing 0.75mm ID x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)- Non-aspirating. Operates best between 1.5 - 2.5ml/min

TAR30-07-CV6T

(Ceramic) (HF)Non-aspirating.Pump-rate

The Ceramic VeeSpray nebulizer is made from alumina ceramic, making itideal for HF analyses. It provides reproducible performance when working withsamples containing large particulates. It has the same 6mm diameter as thestandard concentric and the Alumina material makes it the most robust andabrasion resistant ICP nebulizer. TDS tolerance, typically up to 30%.Hightolerance to particulates, typically up to 300umNote:- Includes TVSS-075 T VeeSpray Nebulizer Sample Tubing 0.75mm ID x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)- Non-aspirating. Operates best between 1.5 - 2.5ml/min

MICROMIST - THE LOW UPTAKE NEBULIZER FOR ALL ICPSThe MicroMist micro-uptake glass concentric nebulizer offers highperformance for limited sample volumes. It makes routine ICP-MS Hgdeterminations possible and reduces matrix effects when used with GlassExpansion's Cinnabar spray chamber

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 0.7

AR30-07-FM06 6AR30-07-FM02 2AR30-07-FM01 1AR30-07-FM005

Includes TEZT-050 T EzyFit Connector with 0.50mmID x 1.3mm OD x 700mm L tubing (1 unit)

0,5TAR30-07-FM06ET 6TAR30-07-FM02ET 2TAR30-07-FM01ET 1

TAR30-07-FM005ET

Note:- Includes TEL-1TEzyLok Connector Kit- This nebulizersupersedes AR30-07-FM06

0,5

POLYCON - FOR ROUTINE HIGH PRECISION HF ANALYSESThe PolyCon concentric nebulizer represents the choice nebulizer for highprecision analyses involving samples digested in HF. The PolyCon has beenused successfully in ICP desolvators such as the MCN-6000, where hightemperatures are encountered. It has become a favorite in the semi conductorindustry, and has enabled analysts to produce accurate (r = 0.9998) calibrationcurves for low-ppt levels of Na, K, Fe and Ca in 30% hydrogen peroxide

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 0.7

TAR30-07-CP2T

- Includes TSTT-075 T Standard Sample Tubing0.75mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

2

TAR30-07-CP06 T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,6

TAR30-07-CP02T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,2

TAR30-07-CP01T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,1

TAR30-07-CP005T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,05

OPALMIST - IDEAL FOR THE GEOCHEMISTRY & SEMICONDUCTOR INDUSTRY

Page 25: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

25

The OpalMist PFA concentric nebulizer represents the choice nebulizer forhigh precision analyses involving analyses requiring high chemical resistanceto HF, alkalis and organics. It also provides excellent results for traceanalyses.

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 0.7

TAR30-07-PFA2T

- Includes TSTT-075 T Standard Sample Tubing0.75mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

2

TAR30-07-PFA06 T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,6

TAR30-07-PFA02T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,2

TAR30-07-PFA01T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,1

TAR30-07-PFA005T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,05

§§ KKIITTSS

Ref

Radial ABC Torch with Mounting Bracket andInstallation KitT30-808-0805T Varian Radial ABC Fully Demountable Torch

T31-808-0500T

Mounting Bracket for Vista Radial ABC FullyDemountable Torch

TKT-806-0011T

T31-806-0009T

Installation Kit for Vista Radial ABC FullyDemountable Torch

Varian Radial ICP-OES KitTAR30-07-FSS2ET

Sea Spray uptake=2ml/min

TEZT-075T

EzyFit with 1.3mm OD x 0.75mm ID x 700mmlong sample tube (Pkt.10)

T20-809-0285HET

Twister with Helix

TKT-806-0011T

Radial ABC Torch with Mounting Bracket andInstallation Kit

TGAZ-06T GazFit Connectors (Pkt.4) - for 6mm OD side arm

TKT-8037BT

T31-800-0003T Varian Radial Quartz Torch BonnetVarian Radial All Glass System KitT20-809-0222HET

Twister with Helix

T30-808-0875T

Varian Vista Radial Torch with Ball Joint 12/5,1.5mm tip

T31-809-0549T Glass Transfer Tube – 160TKT-8046AT

T21-100-T CSC Adjustable Mount

Page 26: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

26

VVAARRIIAANN VVIISSTTAA --AAXXIIAALL

§§ TTOORRCCHHEESS

Réf RéfVARIAN Désignation TORCHE

800-12T30-808-0478T

20-100904-00

Low Flow, one piece w/90 degree stembend –AxialVarian Axial Quartz Torch with 90Deg. Bend & 2.3mm Injector, 6mmOD side arms

T30-808-9983T

Varian Axial Quartz Torch (HighSolids) with 90 Deg. Bend & 2.3mmInjector

800-14T30-800-0014T

2010081200 Varian Axial Quartz Torch 2.3mmInjector, 6mm OD side arms

800-16 20-100904-00 Replaced by 800-12

800-49 99-100568-00 axial – complete Dismountable(injecteur1.8mm)

800-15 2010083400 Torch Axial Dismountable

800-45 24-100675-00 Alumina injector 1.8800-46 N/A Alumina injector 2.5

800-41 20-100730-00 Quartz injector 1.8

800-42 20-100775-00 Quartz injector 0.8

800-48 99-100573-00 PTFE injector holder

Page 27: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

27

Ref TORCHES DEMONTABLES GLASSEXPANSION

Varian Axial Semi Demountable Torch

T30-808-0353T

Varian Axial Semi Demountable Quartz TorchBody, 6mm OD side arms

T31-808-0400T Tapered Quartz Injector 2.4mm

T31-808-0863T

Semi-DMT Torch Adaptor 8/44 with right anglebend

TGAZ-08T GazFit Connectors (Pkt.2) - for 8mm OD armTGAZ-06T GazFit Connectors (Pkt.4) - for 6mm OD side arm

T31-100-0105T

Extractor Tool for Semi Demountable Torch,15.2mm (Varian)

T31-808-0544T Tapered Quartz Injector 1.0mmT31-808-0543T Tapered Quartz Injector 1.5mmT31-808-0545T Tapered Quartz Injector 1.8mm

T30-808-0379T

T31-808-0400T Tapered Quartz Injector 2.4mmVarian Axial Semi Demountable Torch for HF

T30-808-0353T

Varian Axial Semi Demountable Quartz TorchBody, 6mm OD side arms

T31-808-0401T Tapered Alumina Injector 2.4mm

T31-808-0863T

Semi-DMT Torch Adaptor 8/44 with right anglebend

TGAZ-08T GazFit Connectors (Pkt.2) - for 8mm OD armTGAZ-06T GazFit Connectors (Pkt.4) - for 6mm OD side arm

T30-808-0383T

T31-100-0105T Extractor Tool for Semi Demountable Torch,15.2mm (Varian)

T31-808-0353T

Varian Axial Semi Demountable Quartz Torch Body, 6mm OD sidearms

T31-808-0177T Varian Axial Semi Demountable Quartz Torch Body, Short

T31-808-0381T Torch Adapter 8/44

Page 28: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

28

§§ SSPPRRAAYY CCHHAAMMBBEERR WWIITTHH OO RRIINNGG

Ref Designation Spray Chamber

800-22 Spray Chamber for MLN nebulizer( modified Lichte) (See description atend of catalogue)

Chambre GLASSEXPANSION

If you prefer systems without seals please check the Helix model

T20-809-0600T

VARIAN ref20-100817-00

Tracey cyclonic - an industry standardTracey Spray Chamber is a 50ml cyclonic spray chamber which hasexcellent stability with low memory and matrix effects.Note: For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0183T

Cinnabar Cyclonic - the low volume spray chamber 20mlThe Cinnabar spray chamber gives good sensitivity at very low uptakes,while reducing memory and matrix effects. Designed for use with GlassExpansion's MicroMist nebulizersNote: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0285T

Twister cyclonic - reduces solvent load 50mlThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is requiredwhen using this spray chamber with VeeSpray, OpalMist and PolyConnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0448T

Twinnabar cyclonic - low volume, low solvent load – 20mlThe Twinnabar cyclonic spray chamber is a low volume spray chamberwith a central transfer tube (or baffle), combining the benefits of theTwister and the Cinnabar. It combines excellent precision with a very fastwashout.Note: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0129T

Jacketed Tracey spray chamber (borosilicate glass material) 50mlThe Tracey spray chamber has excellent sensitivity and stability with lowmemory and matrix effects. Can be thermostated to constant temperatureto ensure highly reproducible results. Alternatively can be cooled tosuppress volatilization, allowing the direct aspiration of highly volatilesolvents such as naphtha and petrol/gasolineNote: For your convenience includes TUFT-075 T UniFit Connector (1 unit)and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitablefor jacketed spray chambers)

T20-809-0207T

Jacketed Cinnabar spray chamber (borosilicate glass material) 20mlThe Jacketed Cinnabar cyclonic spray chamber can be thermostated toconstant temperature to ensure highly reproducible results. Can also becooled to suppress volatilization, allowing the direct aspiration of highlyvolatile solvents such as naphtha and petrol/gasoline.Note:- Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit) andTQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitable forjacketed spray chambers)

Page 29: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

29

T20-809-0366T

Twister cyclonic - reduces solvent load 50 mlCharacteristic identical to 20-809-0285.The Jacketed Twister cyclonic spray chamber can be thermostated toconstant temperature to ensure highly reproducible results. Can also becooled to suppress volatilization, allowing the direct aspiration of highlyvolatile solvents such as naphtha and petrol/gasoline.Note:- For your convenience includes TUFT-075 T UniFit Connector (1 unit)and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitablefor jacketed spray chambers)

T21-808-0553T

Varian Vgroove Nebulizer Adaptor - for Traceys & Twisters, Required foruse with Varian designed Vgroove type nebulizers

T20-808-0521T

HF resistant Tracey spray chamber 50mlThe HF resistant Tracey spray chamber has excellent sensitivity with lowmemory and matrix effects. It is designed for use with Glass Expansion'sPolyCon nebulizersNote:- Nebulizer adaptor T21-808-0257 T is suitable for use with VeeSpray,OpalMist and PolyCon nebulizers. Nebulizer adaptor P/N T21-808-0256 T isrequired when using this spray chamber with 6mm glass concentricnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

§§ SSPPRRAAYY CCHHAAMMBBEERR WWIITTHHOOUUTT OO RRIINNGG «« HHEELLIIXX SSYYSSTTEEMM »»

Most ICP spectrometers rely on an O-ring seal between the nebulizer and the spray chamber. However, eventhe most chemically resistant O-rings are prone to wear and tear and require regular replacement. They alsotend to bond to a glass nebulizer, making the nebulizer difficult to remove. To eliminate these problems, GlassExpansion has developed Helix - the user friendly nebulizer fitting.

RefDesignation

Spray chamber

T20-809-0600HET

Tracey cyclonic - an industry standard - 50mlTracey Spray Chamber is a 50ml cyclonic spray chamber which hasexcellent stability with low memory and matrix effects.Note: For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0183HET

Cinnabar Cyclonic - the low volume spray chamber - 20mlThe Cinnabar spray chamber gives good sensitivity at very low uptakes,while reducing memory and matrix effects. Designed for use with GlassExpansion's MicroMist nebulizersNote: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0285HET

Twister cyclonic - reduces solvent load 50mlThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is requiredwhen using this spray chamber with VeeSpray, OpalMist and PolyConnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0448HET

Twinnabar cyclonic - low volume, low solvent load - 20mlThe Twinnabar cyclonic spray chamber is a low volume spray chamberwith a central transfer tube (or baffle), combining the benefits of theTwister and the Cinnabar. It combines excellent precision with a very fastwashout.Note: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

Page 30: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

30

T20-809-0129HET

Twister cyclonic - reduces solvent load - 50mlThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is requiredwhen using this spray chamber with VeeSpray, OpalMist and PolyConnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0207HET

Jacketed Tracey spray chamber (borosilicate glass material) - 50mlThe Tracey spray chamber has excellent sensitivity and stability with lowmemory and matrix effects. Can be thermostated to constant temperatureto ensure highly reproducible results. Alternatively can be cooled tosuppress volatilization, allowing the direct aspiration of highly volatilesolvents such as naphtha and petrol/gasolineNote: For your convenience includes TUFT-075 T UniFit Connector (1 unit)and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitablefor jacketed spray chambers)

T20-809-0366HET

Twister cyclonic - reduces solvent load - 50 mlCharacteristic identical to 20-809-0285.The Jacketed Twister cyclonic spray chamber can be thermostated toconstant temperature to ensure highly reproducible results. Can also becooled to suppress volatilization, allowing the direct aspiration of highlyvolatile solvents such as naphtha and petrol/gasoline.Note:- For your convenience includes TUFT-075 T UniFit Connector (1 unit)and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitablefor jacketed spray chambers)

T70-100-0152T Helix Locking Screw

T70-100-0237T Helix Seal

§§ NNEEBBUULLIIZZEERRSS

CONIKAL - AN INDUSTRY STANDARDGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)Suggested Operation: 30 0.7 2

AR30-07-FC3Equivalent OEMRef 2010081600

The Conikal concentric nebulizer gives the most reproducible results forstandard ICP analyses. It represents the choice nebulizer for high precision,routine aqueous and organic applications. High tolerance to particulates,typically up to 75um. TDS tolerance, typically up to 5%Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-07-FC3ET

Equivalent OEMRef 2010081600

Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x1.3mm OD x 700mm L tubing (1 unit)- Includes TEL-1 TEzyLok Connector Kit- This nebulizer supersedes AR30-07-FC3

SEASPRAY - THE HIGH DISSOLVED SOLIDS NEBULIZERGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)Suggested Operation: 30 0.7 2

AR30-07-FSS2Equivalent OEM ref 2010096400

The SeaSpray concentric nebulizer offers outstanding nebulization efficiencyfor trace level analyses. It offers freedom from clogging while nebulizingsolutions to the limit of solubility of most mineral salts (up to 20%), andconferring significant sensitivity gains. Accept particles up to 75µm- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

Page 31: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

31

TAR30-07-FSS2ET

Equivalent OEM ref 2010096400

IdemNote:- Includes TEL-1 TEzyLok Connector Kit- This nebulizer supersedes AR30-07-FC3

SLURRY - FOR SLURRIES OR SUSPENSIONSGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)

Suggested Operation:30 0.7 6

AR30-07-FS6 The Slurry glass concentric nebulizer is ideal for specialized applicationsrequiring the aspiration of slurries or suspensions. It's capillary bore is 50%larger than standard concentric which reduces the possibility of particleblockage, while giving excellent signal stability. High tolerance to particulates,typically up to 150um. Slurry nebulizers have a natural liquid uptake of6ml/min but operates best between 1.5 - 2.5ml/min- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-07-FM06ET Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)- Includes TEL-1 TEzyLok Connector Kit- Operates best between 1.5 - 2.5ml/min. This nebulizer supersedes AR27-075-FS6

VEESPRAY - HANDLES HIGH PARTICLE AND TDS LOADS BESTGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)

30 0.7 6TAR30-07-QV6T

(Quartz)Non-aspirating.

This VeeSpray nebulizer is made from quartz. It provides reproducibleperformance when working with samples containing large particulates. It hasthe same 6mm diameter as the standard concentric nebulizer. TDS tolerance,typically up to 30%. High tolerance to particulates, typically up to 300umNote:- Includes TVSS-075 T VeeSpray Nebulizer Sample Tubing 0.75mm ID x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)- Non-aspirating. Operates best between 1.5 - 2.5ml/min

TAR30-07-CV6T

(Ceramic) (HF)Non-aspirating.Pump-rate

The Ceramic VeeSpray nebulizer is made from alumina ceramic, making itideal for HF analyses. It provides reproducible performance when working withsamples containing large particulates. It has the same 6mm diameter as thestandard concentric and the Alumina material makes it the most robust andabrasion resistant ICP nebulizer. TDS tolerance, typically up to 30%.Hightolerance to particulates, typically up to 300umNote:- Includes TVSS-075 T VeeSpray Nebulizer Sample Tubing 0.75mm ID x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)- Non-aspirating. Operates best between 1.5 - 2.5ml/min

MICROMIST - THE LOW UPTAKE NEBULIZER FOR ALL ICPSThe MicroMist micro-uptake glass concentric nebulizer offers highperformance for limited sample volumes. It makes routine ICP-MS Hgdeterminations possible and reduces matrix effects when used with GlassExpansion's Cinnabar spray chamber

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 0.7

AR30-07-FM06 6AR30-07-FM02 2AR30-07-FM01 1AR30-07-FM005

Includes TEZT-050 T EzyFit Connector with 0.50mmID x 1.3mm OD x 700mm L tubing (1 unit)

0,5TAR30-07-FM06ET 6TAR30-07-FM02ET 2TAR30-07-FM01ET

Note:- Includes TEL-1 1

Page 32: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

32

TAR30-07-FM005ET

TEzyLok Connector Kit- This nebulizer supersedes AR30-07-FM06 0,5

POLYCON - FOR ROUTINE HIGH PRECISION HF ANALYSESThe PolyCon concentric nebulizer represents the choice nebulizer for highprecision analyses involving samples digested in HF. The PolyCon has beenused successfully in ICP de solvators such as the MCN-6000, where hightemperatures are encountered. It has become a favorite in the semi conductorindustry, and has enabled analysts to produce accurate (r = 0.9998) calibrationcurves for low-ppt levels of Na, K, Fe and Ca in 30% hydrogen peroxide

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 0.7

TAR30-07-CP2T

- Includes TSTT-075 T Standard Sample Tubing0.75mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

2

TAR30-07-CP06 T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,6

TAR30-07-CP02T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,2

TAR30-07-CP01T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,1

TAR30-07-CP005T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,05

OPALMIST - IDEAL FOR THE GEOCHEMISTRY & SEMICONDUCTOR INDUSTRYThe OpalMist PFA concentric nebulizer represents the choice nebulizer forhigh precision analyses involving analyses requiring high chemical resistancyto HF, alkalis and organics. It also provides excellent results for traceanalyses.

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 0.7

TAR30-07-PFA2T

- Includes TSTT-075 T Standard Sample Tubing0.75mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

2

TAR30-07-PFA06 T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,6

TAR30-07-PFA02T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,2

TAR30-07-PFA01T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,1

TAR30-07-PFA005T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,05

§§ KKIITTSS

Ref

Axial ABC Torch with Mounting Bracket and InstallationKitT30-808-0878T Varian Axial ABC Fully Demountable Torch

T31-808-1094T

Mounting Bracket for Vista Axial ABC FullyDemountable Torch

TKT-806-0012T

T31-806-0010T

Installation Kit for Vista Axial ABC FullyDemountable Torch

Varian Axial ICP-OES Kit

Page 33: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

33

TAR30-07-FSS2ET SeaSpray uptake=2ml/min

TEZT-075T

EzyFit with 1.3mm OD x 0.75mm ID x700mm long sample tube (Pkt.10)

T20-809-0285HET Twister with Helix

TKT-806-0012T

Axial ABC Torch with Mounting Bracket andInstallation Kit

TKT-8039BT

TGAZ-06T

GazFit Connectors (Pkt.4) - for 6mm OD sidearm

Varian Axial All Glass System KitT20-809-0222HET Twister with Helix

T30-808-0540T

Glass Transfer Tube (links 808-0540 tospray chamber with ball joint) + JC-13 Clip

T31-809-0274T Glass Transfer Tube – 160TKT-8045AT

T21-100-0215T CSC Adjustable MountVarian Vista Axial ICP-OES Kit HFTAR30-07-CP2T PolyCon uptake=2ml/min

TSTT-050T

Standard Sample Tubing 1.3mm OD x0.50mm ID x 10m long

T20-808-0521T HF TraceyT30-808-0383T Varian Axial Semi Demountable Torch

TKT-8044AT

T31-808-0401T Tapered Alumina Injector 2.4mm

Page 34: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

34

VVAARRIIAANN LLIIBBEERRTTYY IIII --AAXXIIAALL

§§ TTOORRCCHHEESS

Réf RéfVARIAN Désignation TORCHE

800-12 20-100904-00Varian Axial Quartz Torch with90 Deg. Bend & 2.3mmInjector, 6mm OD side arms

800-14 2010081200Varian Axial Quartz Torch2.3mm Injector, 6mm OD sidearms

800-16 20-100904-00 Remplaced by 800-12

800-49 99-100568-00 axial – complete dismountable(injecteur1.8mm)

800-15 2010083400 Torch Axial dismountable

800-45 24-100675-00 Alumina injector 1.8800-46 N/A Alumina injector 2.5

800-41 20-100730-00 Quartz injector 1.8

800-42 20-100775-00 Quartz injector 0.8

800-48 99-100573-00 PTFE injector holder

Ref TORCHES DEMONTABLESGLASS EXPANSION

Varian Axial Semi Demountable Torch

T30-808-0353T

Varian Axial Semi Demountable Quartz TorchBody, 6mm OD side arms

T31-808-0400T Tapered Quartz Injector 2.4mm

T31-808-0863T

Semi-DMT Torch Adaptor 8/44 with right anglebend

TGAZ-08T GazFit Connectors (Pkt.2) - for 8mm OD arm

TGAZ-06T

GazFit Connectors (Pkt.4) - for 6mm OD sidearm

T31-100-0105T

Extractor Tool for Semi Demountable Torch,15.2mm (Varian)

T31-808-0544T Tapered Quartz Injector 1.0mmT31-808-0543T Tapered Quartz Injector 1.5mmT31-808-0545T Tapered Quartz Injector 1.8mm

T30-808-0379T

T31-808-0400T Tapered Quartz Injector 2.4mmVarian Axial Semi Demountable Torch for HF

T30-808-0353T

Varian Axial Semi Demountable Quartz TorchBody, 6mm OD side arms

T31-808-0401T Tapered Alumina Injector 2.4mm

T30-808-0383T

T31-808-0863T

Semi-DMT Torch Adaptor 8/44 with right anglebend

Page 35: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

35

TGAZ-08T GazFit Connectors (Pkt.2) - for 8mm OD arm

TGAZ-06T

GazFit Connectors (Pkt.4) - for 6mm OD sidearm

T31-100-0105T Extractor Tool for Semi Demountable Torch,15.2mm (Varian)

T31-808-0353T

Varian Axial Semi Demountable Quartz Torch Body, 6mm ODside arms

T31-808-0177T Varian Axial Semi Demountable Quartz Torch Body, Short

T31-808-0863T Torch Adapter 8/44

§§ SSPPRRAAYY CCHHAAMMBBEERR WWIITTHH OO RRIINNGG

Ref Designation Spray Chamber

800-22 Spray Chamber for MLN nebulizer( modified Lichte) (See description at endof catalogue)

Chambre GLASSEXPANSION

If you wish a nebulizer connecting system without O Ring see following HELIX section.

T20-809-0600T

VARIAN ref20-100817-00

Tracey cyclonic - an industry standardTracey Spray Chamber is a 50ml cyclonic spray chamber which has excellentstability with low memory and matrix effects.Note: For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0183T

Cinnabar Cyclonic - the low volume spray chamber 20mlThe Cinnabar spray chamber gives good sensitivity at very low uptakes, whilereducing memory and matrix effects. Designed for use with Glass Expansion'sMicroMist nebulizersNote: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is required whenusing this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0285T

Twister cyclonic - reduces solvent load 50mlThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is required whenusing this spray chamber with VeeSpray, OpalMist and PolyCon nebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0448T

Twinnabar cyclonic - low volume, low solvent load – 20mlThe Twinnabar cyclonic spray chamber is a low volume spray chamber with acentral transfer tube (or baffle), combining the benefits of the Twister and theCinnabar. It combines excellent precision with a very fast washout.Note: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is required whenusing this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0129T

Jacketed Tracey spray chamber (borosilicate glass material) 50mlThe Tracey spray chamber has excellent sensitivity and stability with lowmemory and matrix effects. Can be thermostated to constant temperature toensure highly reproducible results. Alternatively can be cooled to suppressvolatilization, allowing the direct aspiration of highly volatile solvents such asnaphtha and petrol/gasolineNote: For your convenience includes TUFT-075 T UniFit Connector (1 unit) andTQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitable forjacketed spray chambers)

Page 36: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

36

T20-809-0207T

Jacketed Cinnabar spray chamber (borosilicate glass material) 20mlThe Jacketed Cinnabar cyclonic spray chamber can be thermostated toconstant temperature to ensure highly reproducible results. Can also becooled to suppress volatilization, allowing the direct aspiration of highly volatilesolvents such as naphtha and petrol/gasoline.Note:- Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is required whenusing this spray chamber with OpalMist and PolyCon nebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit) and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitable for jacketedspray chambers)

T20-809-0366T

Twister cyclonic - reduces solvent load 50 mlCharacteristic identical to 20-809-0285.The Jacketed Twister cyclonic spray chamber can be thermostated toconstant temperature to ensure highly reproducible results. Can also becooled to suppress volatilization, allowing the direct aspiration of highly volatilesolvents such as naphtha and petrol/gasoline.Note:- For your convenience includes TUFT-075 T UniFit Connector (1 unit) andTQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitable forjacketed spray chambers)

T21-808-0553T

Varian Vgroove Nebulizer Adaptor - for Traceys & Twisters, Required for usewith Varian designed Vgroove type nebulizers

T20-808-0521T

HF resistant Tracey spray chamber 50mlThe HF resistant Tracey spray chamber has excellent sensitivity with lowmemory and matrix effects. It is designed for use with Glass Expansion'sPolyCon nebulizersNote:- Nebulizer adaptor T21-808-0257 T is suitable for use with VeeSpray, OpalMistand PolyCon nebulizers. Nebulizer adaptor P/N T21-808-0256 T is requiredwhen using this spray chamber with 6mm glass concentric nebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

§§ SSPPRRAAYY CCHHAAMMBBEERR WWIITTHHOOUUTT OO RRIINNGG «« HHEELLIIXX SSYYSSTTEEMM »»

Most ICP spectrometers rely on an O-ring seal between the nebulizer and the spray chamber. However, eventhe most chemically resistant O-rings are prone to wear and tear and require regular replacement. They alsotend to bond to a glass nebulizer, making the nebulizer difficult to remove. To eliminate these problems, GlassExpansion has developed Helix - the user friendly nebulizer fitting.

RefDésignation

Spray chamber

T20-809-0600HET

Tracey cyclonic - an industry standard - 50mlTracey Spray Chamber is a 50ml cyclonic spray chamber which hasexcellent stability with low memory and matrix effects.Note: For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0183HET

Cinnabar Cyclonic - the low volume spray chamber - 20mlThe Cinnabar spray chamber gives good sensitivity at very low uptakes,while reducing memory and matrix effects. Designed for use with GlassExpansion's MicroMist nebulizersNote: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

Page 37: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

37

T20-809-0285HET

Twister cyclonic - reduces solvent load 50mlThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is requiredwhen using this spray chamber with VeeSpray, OpalMist and PolyConnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0448HET

Twinnabar cyclonic - low volume, low solvent load - 20mlThe Twinnabar cyclonic spray chamber is a low volume spray chamberwith a central transfer tube (or baffle), combining the benefits of theTwister and the Cinnabar. It combines excellent precision with a very fastwashout.Note: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0129HET

Twister cyclonic - reduces solvent load - 50mlThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is requiredwhen using this spray chamber with VeeSpray, OpalMist and PolyConnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0207HET

Jacketed Tracey spray chamber (borosilicate glass material) - 50mlThe Tracey spray chamber has excellent sensitivity and stability with lowmemory and matrix effects. Can be thermostated to constant temperatureto ensure highly reproducible results. Alternatively can be cooled tosuppress volatilization, allowing the direct aspiration of highly volatilesolvents such as naphtha and petrol/gasolineNote: For your convenience includes TUFT-075 T UniFit Connector (1 unit)and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitablefor jacketed spray chambers)

T20-809-0366HET

Twister cyclonic - reduces solvent load - 50 mlCharacteristic identical to 20-809-0285.The Jacketed Twister cyclonic spray chamber can be thermostated toconstant temperature to ensure highly reproducible results. Can also becooled to suppress volatilization, allowing the direct aspiration of highlyvolatile solvents such as naphtha and petrol/gasoline.Note:- For your convenience includes TUFT-075 T UniFit Connector (1 unit)and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitablefor jacketed spray chambers)

T70-100-0152T Helix Locking Screw

T70-100-0237T Helix Seal

§§ NNEEBBUULLIIZZEERRSS

CONIKAL - AN INDUSTRY STANDARDGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)Suggested Operation:

30 1 3

Page 38: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

38

AR30-07-FC3Equivalent OEMRef 2010081600

The Conikal concentric nebulizer gives the most reproducible results forstandard ICP analyses. It represents the choice nebulizer for high precision,routine aqueous and organic applications. High tolerance to particulates,typically up to 75um. TDS tolerance, typically up to 5%Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-1-FC3ET

Equivalent OEMRef 2010081600

Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x1.3mm OD x 700mm L tubing (1 unit)- Includes TEL-1 TEzyLok Connector Kit- This nebulizer supersedes AR30-1-FC3

SEASPRAY - THE HIGH DISSOLVED SOLIDS NEBULIZERGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)Suggested Operation: 30 0.7 2

AR30-1-FSS2Equivalent OEM ref 2010096400

The SeaSpray concentric nebulizer offers outstanding nebulization efficiencyfor trace level analyses. It offers freedom from clogging while nebulizingsolutions to the limit of solubility of most mineral salts (up to 20%), andconferring significant sensitivity gains. Accept particles up to 75µm- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-1-FSS2ET

Equivalent OEM ref 2010096400

IdemNote:- Includes TEL-1 TEzyLok Connector Kit- This nebulizer supersedes AR30-1-FC3

SLURRY - FOR SLURRIES OR SUSPENSIONSGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)

Suggested Operation:30 0.7 6

AR30-1-FS6 The Slurry glass concentric nebulizer is ideal for specialized applicationsrequiring the aspiration of slurries or suspensions. It's capillary bore is 50%larger than standard concentric which reduces the possibility of particleblockage, while giving excellent signal stability. High tolerance to particulates,typically up to 150um. Slurry nebulizers have a natural liquid uptake of6ml/min but operates best between 1.5 - 2.5ml/min- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-1-FM06ET Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)- Includes TEL-1 TEzyLok Connector Kit- Operates best between 1.5 - 2.5ml/min. This nebulizer supersedes AR27-15-FS6

VEESPRAY - HANDLES HIGH PARTICLE AND TDS LOADS BESTGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)

30 0.7 6TAR30-1-QV6T

(Quartz)Non-aspirating.

This VeeSpray nebulizer is made from quartz. It provides reproducibleperformance when working with samples containing large particulates. It hasthe same 6mm diameter as the standard concentric nebulizer. TDS tolerance,typically up to 30%. High tolerance to particulates, typically up to 300umNote:- Includes TVSS-075 T VeeSpray Nebulizer Sample Tubing 0.75mm ID x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)- Non-aspirating. Operates best between 1.5 - 2.5ml/min

Page 39: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

39

TAR30-1-CV6T

(Ceramic) (HF)Non-aspirating.Pump-rate

The Ceramic VeeSpray nebulizer is made from alumina ceramic, making itideal for HF analyses. It provides reproducible performance when working withsamples containing large particulates. It has the same 6mm diameter as thestandard concentric and the Alumina material makes it the most robust andabrasion resistant ICP nebulizer. TDS tolerance, typically up to 30%.Hightolerance to particulates, typically up to 300umNote:- Includes TVSS-075 T VeeSpray Nebulizer Sample Tubing 0.75mm ID x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)- Non-aspirating. Operates best between 1.5 - 2.5ml/min

MICROMIST - THE LOW UPTAKE NEBULIZER FOR ALL ICPSThe MicroMist micro-uptake glass concentric nebulizer offers highperformance for limited sample volumes. It makes routine ICP-MS Hgdeterminations possible and reduces matrix effects when used with GlassExpansion's Cinnabar spray chamber

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 0.7

AR30-1-FM06 6AR30-1-FM02 2AR30-1-FM01 1AR30-1-FM005

Includes TEZT-050 T EzyFit Connector with 0.50mmID x 1.3mm OD x 700mm L tubing (1 unit)

0,5TAR30-1-FM06ET 6TAR30-1-FM02ET 2TAR30-1-FM01ET 1

TAR30-1-FM005ET

Note:- Includes TEL-1TEzyLok Connector Kit- This nebulizersupersedes AR30-1-FM06

0,5

POLYCON - FOR ROUTINE HIGH PRECISION HF ANALYSESThe PolyCon concentric nebulizer represents the choice nebulizer for highprecision analyses involving samples digested in HF. The PolyCon has beenused successfully in ICP de solvators such as the MCN-6000, where hightemperatures are encountered. It has become a favorite in the semi conductorindustry, and has enabled analysts to produce accurate (r = 0.9998) calibrationcurves for low-ppt levels of Na, K, Fe and Ca in 30% hydrogen peroxide

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 0.7

TAR30-1-CP2T

- Includes TSTT-075 T Standard Sample Tubing0.75mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

2

TAR30-1-CP06 T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,6

TAR30-1-CP02T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,2

TAR30-1-CP01T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,1

TAR30-1-CP005T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,05

OPALMIST - IDEAL FOR THE GEOCHEMISTRY & SEMICONDUCTOR INDUSTRYThe OpalMist PFA concentric nebulizer represents the choice nebulizer forhigh precision analyses involving analyses requiring high chemical resistanceto HF, alkalis and organics. It also provides excellent results for traceanalyses.

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 0.7

TAR30-1-PFA2T

- Includes TSTT-075 T Standard Sample Tubing0.75mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

2

Page 40: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

40

TAR30-1-PFA06 T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,6

TAR30-1-PFA02T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,2

TAR30-1-PFA01T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,1

TAR30-1-PFA005T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,05

§§ KKIITTSS

Ref

Varian Liberty Axial ICP-OES KitTAR30-1-FSS2ET SeaSpray uptake=2ml/min

TEZT-15T

EzyFit with 1.3mm OD x 0.75mm ID x700mm long sample tube (Pkt.10)

T20-809-0285HET Twister with Helix

TKT-806-0012T

Axial ABC Torch with Mounting Bracket andInstallation Kit

TKT-8038BT

TGAZ-06T

GazFit Connectors (Pkt.4) - for 6mm OD sidearm

Varian Liberty Axial ICP-OES Kit HFTAR30-1-CP2T PolyCon uptake=2ml/min

TSTT-050T

Standard Sample Tubing 1.3mm OD x0.50mm ID x 10m long

T20-808-0521T HF TraceyT30-808-0383T Varian Axial Semi Demountable Torch

TKT-0042AT

T31-808-0401T Tapered Alumina Injector 2.4mm

Page 41: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

41

VVAARRIIAANN UULLTTRRAAMMAASSSS

§§ TTOORRCCHHSS

Réf RéfVARIAN Désignation

800-06 20-100783-00 Torch ICP-MS

800-51 99-100717-00 Torch- Dismountablecomplete

800-11 20-100834-0000 Torch Dismountable bodyonly

800-45 24-100675-00 Alumina injector 1.8800-46 N/A Alumina injector 2.5

800-41 20-100730-00 Quartz injector 1.8

800-42 20-100775-00 Quartz injector 0.8

800-48 99-100573-00 Teflon holder tube forinjector

Ref TORCHES DEMONTABLES GLASSEXPANSION

Varian Axial Semi Demountable Torch

T30-808-0709T

Varian Ultramass Semi Demountable Quartz TorchBody, 6mm OD side arms

T31-808-0400T Tapered Quartz Injector 1.5mm

T31-808-0381T

Semi-DMT Torch Adaptor 8/44 with right anglebend

TGAZ-08T GazFit Connectors (Pkt.2) - for 8mm OD armTGAZ-06T GazFit Connectors (Pkt.4) - for 6mm OD side arm

T30-808-1178T

T31-100-0105T

Extractor Tool for Semi Demountable Torch,15.2mm (Varian)

Varian Axial Semi Demountable Torch for HF

T30-808-0709T

Varian Axial Semi Demountable Quartz TorchBody, 6mm OD side arms

T31-808-0938T Tapered Alumina Injector 2.4mm

T31-808-0381T

Semi-DMT Torch Adaptor 8/44 with right anglebend

TGAZ-08T GazFit Connectors (Pkt.2) - for 8mm OD armTGAZ-06T GazFit Connectors (Pkt.4) - for 6mm OD side arm

T30-808-1177T

T31-100-0105T Extractor Tool for Semi Demountable Torch,15.2mm (Varian)

T31-808-0177T Varian Axial Semi Demountable Quartz Torch Body, Short

T31-808-0381T Torch Adapter 8/44

Page 42: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

42

Kit Hydra Trace kit mounted on Ultramass ICP-MS

Page 43: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

43

§§ SSPPRRAAYY CCHHAAMMBBEERR WWIITTHH OO RRIINNGG

Chambre GLASSEXPANSION

If you wish a nebulizer connecting system without O Ring see following HELIX section.

T20-809-0365T

Twister cyclonic – 4 mm pump drain 50 mlThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is required whenusing this spray chamber with VeeSpray, OpalMist and PolyCon nebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0151T

Tracey cyclonic - 4 mm pump drain - 50 mlTracey Spray Chamber is a 50ml cyclonic spray chamber which has excellentstability with low memory and matrix effects.Note: For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0328T

Cinnabar Cyclonic - 4 mm pump drain - 20mlThe Cinnabar spray chamber gives good sensitivity at very low uptakes, whilereducing memory and matrix effects. Designed for use with Glass Expansion'sMicroMist nebulizersNote: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is required whenusing this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0153T

Jacketed Tracey spray chamber (borosilicate glass material) - 4 mmpump drain - 50mlThe Tracey spray chamber has excellent sensitivity and stability with lowmemory and matrix effects. Can be thermostated to constant temperature toensure highly reproducible results. Alternatively can be cooled to suppressvolatilization, allowing the direct aspiration of highly volatile solvents such asnaphtha and petrol/gasolineNote: For your convenience includes TUFT-075 T UniFit Connector (1 unit) andTQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitable forjacketed spray chambers)

T20-809-0292T

Twister cyclonic - reduces solvent load 50ml – with gravity drainThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T s suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is required whenusing this spray chamber with VeeSpray, OpalMist and PolyCon nebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T21-808-0660T Spray Chamber Adaptor Mount

T20-809-0352T

HF resistant Tracey spray chamber 50mlThe HF resistant Tracey spray chamber has excellent sensitivity with lowmemory and matrix effects. It is designed for use with Glass Expansion'sPolyCon nebulizersNote:- Nebulizer adaptor T21-808-0257 T is suitable for use with VeeSpray, OpalMistand PolyCon nebulizers. Nebulizer adaptor P/N T21-808-0256 T is requiredwhen using this spray chamber with 6mm glass concentric nebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

Page 44: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

44

T20-809-0465T

HF resistant Cinnabar chamber 20mlHF Mini Nebulizer Adaptor - for Cinnabar or Twinnabar with PolyCon,OpalMist or VeeSpray NebNote:- Nebulizer adaptor T21-808-0944 T is suitable for use with OpalMist andPolyCon nebulizers. Nebulizer adaptor P/N T21-808-0259 T is required whenusing this spray chamber with 6mm glass concentric nebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0547T PFA Cyclonic VA, 50ml cyclonic, PFA

§§ SSPPRRAAYY CCHHAAMMBBEERR WWIITTHHOOUUTT OO RRIINNGG «« HHEELLIIXX SSYYSSTTEEMM »»

Most ICP spectrometers rely on an O-ring seal between the nebulizer and the spray chamber. However, eventhe most chemically resistant O-rings are prone to wear and tear and require regular replacement. They alsotend to bond to a glass nebulizer, making the nebulizer difficult to remove. To eliminate these problems, GlassExpansion has developed Helix - the user friendly nebulizer fitting.

RefDésignation

Spray chamber

T20-809-0365HET

Twister cyclonic – 4 mm pump drain 50 mlThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is requiredwhen using this spray chamber with VeeSpray, OpalMist and PolyConnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0151HET

Tracey cyclonic - 4 mm pump drain - 50 mlTracey Spray Chamber is a 50ml cyclonic spray chamber which hasexcellent stability with low memory and matrix effects.Note: For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0328HET

Cinnabar Cyclonic - 4 mm pump drain - 20mlThe Cinnabar spray chamber gives good sensitivity at very low uptakes,while reducing memory and matrix effects. Designed for use with GlassExpansion's MicroMist nebulizersNote: Nebulizer adaptor T21-808-0259 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0944 T is requiredwhen using this spray chamber with OpalMist and PolyCon nebulizers.For your convenience includes TUFT-075 T UniFit Connector (1 unit)

T20-809-0153HET

Jacketed Tracey spray chamber (borosilicate glass material) - 4 mmpump drain - 50mlThe Tracey spray chamber has excellent sensitivity and stability with lowmemory and matrix effects. Can be thermostated to constant temperatureto ensure highly reproducible results. Alternatively can be cooled tosuppress volatilization, allowing the direct aspiration of highly volatilesolvents such as naphtha and petrol/gasolineNote: For your convenience includes TUFT-075 T UniFit Connector (1 unit)and TQSM-1/4-4T EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitablefor jacketed spray chambers)

T20-809-0292HET

Twister cyclonic - reduces solvent load 50ml – with gravity drainThe Twister spray chamber lowers solvent load without compromisingdetection limits. Provides good stability for analyzing organics.Note: Nebulizer adaptor T21-808-0256 T is suitable for use with 6mm glassconcentric nebulizers. Nebulizer adaptor P/N T21-808-0257 T is requiredwhen using this spray chamber with VeeSpray, OpalMist and PolyConnebulizers.- For your convenience includes TUFT-075 T UniFit Connector (1 unit)

Page 45: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

45

T21-808-0660T Spray Chamber Adaptor Mount

T70-100-0152T Helix Locking Screw

T70-100-0237T Helix Seal

§§ NNEEBBUULLIIZZEERRSS

CONIKAL - AN INDUSTRY STANDARDGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)Suggested Operation: 30 0.7 2

AR30-07-FC3Equivalent OEM ref 2010081600

The Conikal concentric nebulizer gives the most reproducible results forstandard ICP analyses. It represents the choice nebulizer for high precision,routine aqueous and organic applications. High tolerance to particulates,typically up to 75um. TDS tolerance, typically up to 5%Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-07-FC3ET

Equivalent OEM ref 2010081600

Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x1.3mm OD x 700mm L tubing (1 unit)- Includes TEL-1 TEzyLok Connector Kit- This nebulizer supersedes AR30-07-FC3

SEASPRAY - THE HIGH DISSOLVED SOLIDS NEBULIZERGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)Suggested Operation: 30 0.7 2

AR30-07-FSS2Equivalent OEM ref 2010096400

The SeaSpray concentric nebulizer offers outstanding nebulization efficiencyfor trace level analyses. It offers freedom from clogging while nebulizingsolutions to the limit of solubility of most mineral salts (up to 20%), andconferring significant sensitivity gains. Accept particles up to 75µm- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-07-FSS2ET

Equivalent OEM ref 2010096400

IdemNote:- Includes TEL-1 TEzyLok Connector Kit- This nebulizer supersedes AR30-07-FC3

SLURRY - FOR SLURRIES OR SUSPENSIONSGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)

Suggested Operation:30 0.7 6

AR30-07-FS6 The Slurry glass concentric nebulizer is ideal for specialized applicationsrequiring the aspiration of slurries or suspensions. It's capillary bore is 50%larger than standard concentric which reduces the possibility of particleblockage, while giving excellent signal stability. High tolerance to particulates,typically up to 150um. Slurry nebulizers have a natural liquid uptake of6ml/min but operates best between 1.5 - 2.5ml/min- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

Page 46: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

46

TAR30-07-FM06ET Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)- Includes TEL-1 TEzyLok Connector Kit- Operates best between 1.5 - 2.5ml/min. This nebulizer supersedes AR27-075-FS6

VEESPRAY - HANDLES HIGH PARTICLE AND TDS LOADS BESTGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)

30 0.7 6TAR30-07-QV6T

(Quartz)Non-aspirating.

This VeeSpray nebulizer is made from quartz. It provides reproducibleperformance when working with samples containing large particulates. It hasthe same 6mm diameter as the standard concentric nebulizer. TDS tolerance,typically up to 30%. High tolerance to particulates, typically up to 300umNote:- Includes TVSS-075 T VeeSpray Nebulizer Sample Tubing 0.75mm ID x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)- Non-aspirating. Operates best between 1.5 - 2.5ml/min

TAR30-07-CV6T

(Ceramic) (HF)Non-aspirating.Pump-rate

The Ceramic VeeSpray nebulizer is made from alumina ceramic, making itideal for HF analyses. It provides reproducible performance when working withsamples containing large particulates. It has the same 6mm diameter as thestandard concentric and the Alumina material makes it the most robust andabrasion resistant ICP nebulizer. TDS tolerance, typically up to 30%.Hightolerance to particulates, typically up to 300umNote:- Includes TVSS-075 T VeeSpray Nebulizer Sample Tubing 0.75mm ID x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)- Non-aspirating. Operates best between 1.5 - 2.5ml/min

MICROMIST - THE LOW UPTAKE NEBULIZER FOR ALL ICPSThe MicroMist micro-uptake glass concentric nebulizer offers highperformance for limited sample volumes. It makes routine ICP-MS Hgdeterminations possible and reduces matrix effects when used with GlassExpansion's Cinnabar spray chamber

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 0.7

AR30-07-FM04 4AR30-07-FM02 2AR30-07-FM01 1AR30-07-FM005

Includes TEZT-050 T EzyFit Connector with 0.50mmID x 1.3mm OD x 700mm L tubing (1 unit)

0,5TAR30-1-FM04ET 4TAR30-1-FM02ET 2TAR30-1-FM01ET 1

TAR30-1-FM005ET

Note:- Includes TEL-1TEzyLok Connector Kit- This nebulizersupersedes AR30-07-FM06

0,5

POLYCON - FOR ROUTINE HIGH PRECISION HF ANALYSESThe PolyCon concentric nebulizer represents the choice nebulizer for highprecision analyses involving samples digested in HF. The PolyCon has beenused successfully in ICP de solvators such as the MCN-6000, where hightemperatures are encountered. It has become a favorite in the semi conductorindustry, and has enabled analysts to produce accurate (r = 0.9998) calibrationcurves for low-ppt levels of Na, K, Fe and Ca in 30% hydrogen peroxide

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 1

TAR30-1-CP2T

- Includes TSTT-075 T Standard Sample Tubing0.75mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

2

TAR30-1-CP04T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,4

TAR30-1-CP02T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,2

Page 47: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

47

TAR30-1-CP01T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,1

TAR30-1-CP005T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,05

OPALMIST - IDEAL FOR THE GEOCHEMISTRY & SEMICONDUCTOR INDUSTRYThe OpalMist PFA concentric nebulizer represents the choice nebulizer forhigh precision analyses involving analyses requiring high chemical resistanceto HF, alkalis and organics. It also provides excellent results for traceanalyses.

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 1

TAR30-1-PFA2T

- Includes TSTT-075 T Standard Sample Tubing0.75mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

2

TAR30-1-PFA04T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,4

TAR30-1-PFA02T

- Includes TSTT-050 T Standard Sample Tubing0.50mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,2

TAR30-1-PFA005T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,1

TAR30-1-PFA005T

- Includes TSTT-025 T Standard Sample Tubing0.25mm ID x 1.3mm OD x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)

0,05

§§ KKIITTSS

Ref Type Designation GLASS EXPANSION KIT

KT-9022A

ComprisesAR30-1-FM02WEL20-809-032821-808-0660

200µl/minMini Cyclonic, 20mlMounting adaptor

HYDRA-TRACEKIT

Ideal combination for high sensitivity analysis on low volume of sample. Reduce drastically the matrix effect, memoryeffects and rinsing time

§§ CCOONNEESS

For more information request our catalogue for conesRef Manufacturer’s Ref Spectron designation

UM1001-Ni 99-100698-00 Std. Ni sampler, Cu base1.0mm orificeUM1001C-Ni 99-100920-00 Ni sampler for cool plasma0.8mm orificeUM1001F-Ni 99-100940-00 Ni sampler F-series typeUM1002-Ni 99-100699-00 Std. Ni skimmerUM1002F-Ni 99-100941-00 F-series skimmerUM1006-Pt 99-100700-00 Platinum Sampler15.2mm Pt/10%Rh insertUM1008-Pt 99-100701-00 Platinum skimmer7.6mm Pt/10%Rh insert

Page 48: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

48

VVAARRIIAANN IICCPP//MMSS

§§ TTOORRCCHH

Ref RefVARIAN Designation

T30-808-1206T Varian ICP-MS TorchT31-808-1208T Varian ICP-MS Universal JointT31-808-1207T Varian ICP-MS Make-up In-port

§§ SSPPRRAAYY CCHHAAMMBBEERR WWIITTHH OO RRIINNGG

Chamber GLASSEXPANSION

If you wish a nebulizer connecting system without O Ring see following HELIX section.

T20-808-1209T Varian ICP-MS Spray Chamber

§§ NNEEBBUULLIIZZEERRSS

CONIKAL - AN INDUSTRY STANDARDGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)Suggested Operation: 30 1 2

AR30-1-FC3Equivalent OEM ref 2010081600

The Conikal concentric nebulizer gives the most reproducible results forstandard ICP analyses. It represents the choice nebulizer for high precision,routine aqueous and organic applications. High tolerance to particulates,typically up to 75um. TDS tolerance, typically up to 5%Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-1-FC3E T

Equivalent OEM ref 2010081600

Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x1.3mm OD x 700mm L tubing (1 unit)- Includes TEL-1 TEzyLok Connector Kit- This nebulizer supersedes AR30-07-FC3

SEASPRAY - THE HIGH DISSOLVED SOLIDS NEBULIZERGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)Suggested Operation: 30 1 2

AR30-1-FSS2Equivalent OEM ref 2010096400

The SeaSpray concentric nebulizer offers outstanding nebulization efficiencyfor trace level analyses. It offers freedom from clogging while nebulizingsolutions to the limit of solubility of most mineral salts (up to 20%), andconferring significant sensitivity gains. Accept particles up to 75µm- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-1-FSS2ET

Equivalent OEM ref 2010096400

IdemNote:- Includes TEL-1 TEzyLok Connector Kit- This nebulizer supersedes AR30-07-FC3

SLURRY - FOR SLURRIES OR SUSPENSIONSGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)

Suggested Operation:30 1 6

Page 49: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

49

AR30-1-FS6 The Slurry glass concentric nebulizer is ideal for specialized applicationsrequiring the aspiration of slurries or suspensions. Its capillary bore is 50%larger than standard concentric which reduces the possibility of particleblockage, while giving excellent signal stability. High tolerance to particulates,typically up to 150um. Slurry nebulizers have a natural liquid uptake of6ml/min but operates best between 1.5 - 2.5ml/min- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)

TAR30-1-FS6ET Note:- Includes TEZT-075 T EzyFit Connector with 0.75mm ID x 1.3mm OD x 700mm L tubing(1 unit)- Includes TEL-1 TEzyLok Connector Kit- Operates best between 1.5 - 2.5ml/min. This nebulizer supersedes AR27-075-FS6

VEESPRAY - HANDLES HIGH PARTICLE AND TDS LOADS BESTGas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)

30 1 6TAR30-07-QV6T

(Quartz)Non-aspirating.

This VeeSpray nebulizer is made from quartz. It provides reproducibleperformance when working with samples containing large particulates. It hasthe same 6mm diameter as the standard concentric nebulizer. TDS tolerance,typically up to 30%. High tolerance to particulates, typically up to 300umNote:- Includes TVSS-075 T VeeSpray Nebulizer Sample Tubing 0.75mm ID x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)- Non-aspirating. Operates best between 1.5 - 2.5ml/min

TAR30-07-CV6T

(Ceramic) (HF)Non-aspirating.Pump-rate

The Ceramic VeeSpray nebulizer is made from alumina ceramic, making itideal for HF analyses. It provides reproducible performance when working withsamples containing large particulates. It has the same 6mm diameter as thestandard concentric and the Alumina material makes it the most robust andabrasion resistant ICP nebulizer. TDS tolerance, typically up to 30%.Hightolerance to particulates, typically up to 300umNote:- Includes TVSS-075 T VeeSpray Nebulizer Sample Tubing 0.75mm ID x 700mm L (1 unit)- Includes TSNP-1 T Nebulizer Hose Clip (1 unit)- Non-aspirating. Operates best between 1.5 - 2.5ml/min

MICROMIST - THE LOW UPTAKE NEBULIZER FOR ALL ICPSThe MicroMist micro-uptake glass concentric nebulizer offers highperformance for limited sample volumes. It makes routine ICP-MS Hgdeterminations possible and reduces matrix effects when used with GlassExpansion's Cinnabar spray chamber

Suggested Operation: Gas Pressure (psi) Gas Flow (L/min) Sample Uptake (ml/min)30 1

AR30-1-FM04 4AR30-1-FM02 2AR30-1-FM01 1AR30-1-FM005

Includes TEZT-050 T EzyFit Connector with 0.50mmID x 1.3mm OD x 700mm L tubing (1 unit)

0,5TAR30-1-FM04ET 4TAR30-1-FM02ET 2TAR30-1-FM01ET 1

TAR30-1-FM005ET

Note:- Includes TEL-1TEzyLok Connector Kit- This nebulizersupersedes AR30-07-FM06

0,5

Page 50: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

50

RRFF CCOOIILLSS AANNDD TTOOLLLL FFOORR VVAARRIIAANN IICCPPRead also general information talking about coils services.

T70-900-1000ST Varian Series 2 AxialSilver RF Coil

Liberty Series 2, Vista& MPX

T70-900-1000GT Varian Series 2 AxialGold RF Coil

Liberty Series 2,Vista & MPX

T70-900-1000TT Installation Tool -Varian Series 2 Axial

Liberty Series 2,Vista & MPX

T70-900-1001ST Varian Series 2 RadialSilver RF Coil

Liberty Series 2, Vista& MPX

T70-900-1001GT Varian Series 2 RadialGold RF Coil

Liberty Series 2, Vista& MPX

T70-900-1001TT Installation Tool -Varian Series Radial

Liberty Series 2, Vista& MPX

T70-900-1003ST Varian Series 1 RadialSilver RF Coil

Liberty Series 1

T70-900-1003GT Varian Series 1 RadialGold RF Coil

Liberty Series 1

T70-900-1003TT Installation Tool -Varian Series Radial

Liberty Series 1

Page 51: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

51

NNEEBBUULLIIZZEERR AANNDD CCHHAAMMBBEERR CCOONNNNEEXXIIOONN§§ EEAASSYY LLOOCCKK AARRGGOONN CCOONNNNEECCTTOORR

• Promotes user safety• Stiffening of argon supply tube is no longer a

problem• Eliminates bonding of argon supply tube to nebulizer

side arm• Suitable for Glass Expansion's glass nebulizers

which have the EzyLok side arm• Can be used with 4mm nylon tubing or standard

6mm soft tubing

Constant argon supply and RF power are the two most important requirements for good ICP short termstability. For example, a half-percent leak of argon can generate RSD's of worse than 2%. The most commoncause of argon leaks at nebulizer ports is a stiffening of the argon supply tube over time, leading to aconsequent loss of seal.The EzyLok connection is made with our specially formed nebulizer side arm, which allows it to be pushedand locked securely into the popular 'One Touch Fitting' which incorporates a flexible O-ring seal. Todisconnect the nebulizer, simply push on the release button located at the top of the fitting.The EzyLok connection also improves safety by preventing broken nebulizer side arms. When argon supplytubes made from all or part silicon are used, they tend to bond strongly to the nebulizer glass side arm.Usually ICP users remove the bonded tubing by cutting it away bit by bit with a sharp blade...a very hazardousoperation! The EzyLok easily connects and disconnects the argon supply tube to the nebulizer side arm.

Ref EzyLock GLASS EXPANSION

TEL-1T

ComprenantTQSM-4T

T70-808-0735T

TSNP-1T

EzyLok Kit (for glass concentric nebulizers)

EzylLok Connector for 4mm tubingEzyLok 6 mm Hose AdaptorHose clip, 6 mm

TEL-2T

ComprenantTQSM-4T

T70-808-0735/2T

T6409-16T

EzyLok retrofit Kit, pour tous les nébuliseurs avec tube latéral classique (bourrelet)

EzylLok Connector for 4mm tubing2 x EzyLok 6 mm Hose AdaptorHose clip, 6 mm

EzyFitTEZT-025T EzyFit with 1.3mm OD x 0.25mm ID x 700mm long sample tube (PKT. 10)TEZT-050T EzyFit with 1.3mm OD x 0.50mm ID x 700mm long sample tube (PKT. 10)TEZT2-050T EzyFit 0.50 ID Sample Tube (PKT.10) 1.58mm x 0.50mm ID x 2000mm longTEZT-075T EzyFit with 1.3mm OD x 0.75mm ID x 700mm long sample tube (PKT. 10)TEZT2-075T EzyFit with 1.3mm OD x 0.75mm ID x 2000mm long sample tube (PKT. 10)TEZT-16/50T EzyFit with 1/16 inch OD X 0.50mm ID x 700mm long sample tube (PKT. 10)TEZT-16-25T EzyFit with 1/16 inch OD X 0.25mm ID x 700mm long sample tube (PKT. 10)TEZT-16-07T EzyFit with 1/16 inch OD X 0.07mm ID x 700mm long sample tube (PKT. 10)TEZT-16-75T EzyFit with 1/16 inch OD X 0.75mm ID x 700mm long sample tube (PKT. 10)TEZTS-16-75T EzyFit with 1/16 inch OD X 0.75mm ID x 1500mm long sample tube (PKT. 10)TEZT-0703T EzyFit with 0.75mm OD x 0.3mm ID x 700mm long sample tube (PKT. 10)TEZTFE-050T EzyFit with 1.3mm OD x 0.50mm ID x 700mm long Tefzel sample tube (PKT. 10)

Standard sample tubing (ptfe)TSTT-025T Standard Sample Tubing 1.3mm OD x 0.25mm ID x 10m longTSTT-050T Standard Sample Tubing 1.3mm OD x 0.50mm ID x 10m longTSTT-075T Standard Sample Tubing 1.3mm OD x 0.75mm ID x 10m longTSTT-16/25T Standard Sample Tubing 1/16 inch OD x 0.25mm ID x 10m longTSTT-0703T Standard Sample Tubing 0.75mm x 0.30mm ID x 10m longTSTT-16/50T Tube échantillonneur standard 1/16" OD x 0.50mm ID x 10m longTTFE-050T Standard Sample Tubing 1/16 inch OD x 0.50mm ID x 10m long

Other tubes and clipsTVSS-075T VeeSpray Nébuliseur Tube échantillonneur (PKT. 10)TVKT-0118T PolyCon/VeeSpray Joint et visse Kit (10 Pcs)TV-001T PolyCon/VeeSpray joint Tube échantillonneur O-ringsTSNP-1T Nébuliseur Pressure Hose Clips (PKT 10)

EL-1EL-2

Page 52: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

52

T808-0126T PolyCon Thread CapPFA sample tubing

TPFT-16/07T PFA Sample Tubing 1/16 inch OD x 0.07mm ID x 10m longTPFT-16/13T PFA Sample Tubing 1/16 inch OD x 0.13mm ID x 10m longTPFT-16/18T PFA Sample Tubing 1/16 inch OD x 0.18mm ID x 10m longT1/4PFA-HW T PFA Tubing 1/4 inch X 1/8 inch x 1 Meter

TTEEFFLLOONN TTUUBBEESS AANNDD CCOONNNNEEXXIIOONN FFOORRCCHHAAMMBBEERRSS

§§ UUNNIIFFIITT CCOONNNNEECCTTOORR

• Easy to use• Connect to the chamber drain tube

§§ EEZZYYLLOOCCKK FFOORR TTHHEERRMMOOSSTTAATTEEDDCCHHAAMMBBEERR

• Ease connexion of nylon, Teflon, Polyamides,polyuréthane de ¼’’ tubes

RéfJoints GLASS EXPANSION

TVT-009T Teflon Coated Viton O-rings Pkt. 10 (for GE cyclonic's, nebulizer seal)TVT-9/1.5T Teflon Coated Viton O-rings Pkt. 5 (for 12mm small nebulizer adaptor seal)TVT-10/2T Teflon Coated Viton O-rings Pkt. 10 (16mm large nebulizer adaptor seal)TS-009T Silicon O-rings Pkt 10TKZ-009T Kalrez O-ringTV-044T Viton o-ring for base of HF Tracey spray chamber (PKT 10)

GLASS EXPANSION Clip et connecteurTJC-13 T Metal Ball Joint ClipTKCM-14T Joint Clip B14-NickelTKCM-29T Joint Clip KCM29-Nickel

TQSM-1/4-4T

EzyLok Connector for 1/4 inch Tubing, pack of 4 (suitable for jacketed spraychambers)

TUFT16-75T UniFit with 1/16 inch OD X 0.75mm ID x 700mm long sample tube (PKT. 3)TUFT-075T UniFit with 1.3mm OD X 0.75mm ID x 700mm long sampe tube (PKT. 3)T21-808-0818T 12mm Spray Chamber/Neb Adaptor Set - for CinnabarT21-808-0631T Aridus Nebulizer Adaptor Plug 6mmT21-808-0740T Teflon Mini Neb AdaptorT21-808-0257T HF Nebulizer Adaptor - for Traceys & TwistersT21-808-0944T HF Mini Nebulizer Adaptor - for CinnabarsT21-808-0259T Nebulizer Adaptor 12/6 - for CinnabarT21-808-0256T Nebulizer Adaptor 16/6 - for Tracey & TwisterT70-808-0501T O-ring Set for Neb Adaptor 16/6

T70-100-0237T Helix Seal (Pkt. 4)

T70-100-0152T Helix Locking Screw

T21-808-1010T Nebulizer Teflon Adaptor Plug 6/35

Page 53: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

53

OO RRIINNGG AANNDD CCOONNNNEEXXIIOONN FFOORR TTOORRCCHHSS

RefGLASS EXPANSION connecteurs

TGAZ-08T GazFit connectors, pour tube lateral de 8 mm OD, Packet de 2TGAZ-06T GazFit connectors, pour tube lateral de 6 mm OD, Packet of 4

TGAZ-0604T

GazFit connectors, 2 pour tube lateral de 6 mm OD, 2 pourtube lateral de 4mm OD Packet de 4

TGAZ-05T GazFit connectors, pour tube lateral de 5 mm OD, Packet of 4TGAZ-04T GazFit connectors, pour tube lateral de 4 mm OD, Packet of 4

T31-100-0109T

Extractor Tool for Semi Demountable Torch, 12.2mm(Finnigan)

T31-100-0106T

Extractor Tool for Semi Demountable Torch, 14.2mm(standard size)

T31-100-0105T Extractor Tool for Semi Demountable Torch, 15.2mm (Varian)

T70-VT-011T

Viton seal Teflon coated for spherical connexion pack of 10pces

T70-EZG-CLOTHT

EzyGlide lubricatinf towel for easy mounting and dismountingof internal tubing

SSAAFFEETTYY CCCCEESSSSOOIIRRIIEESS

RéfGLASS EXPANSION connectors

TSAFEGLOVE-smlT Safety Gloves, SmallTSAFEGLOVE-medT Safety Gloves, MediumTSAFEGLOVE-lgeT Safety Gloves, LargeTSAFEGLASS-smlT Safety Glasses, SmallTSAFEGLASS-lgeT Safety Glasses, Large

Page 54: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

54

RRFF CCOOIILLSS:: GGEENNEERRAALLIITTYY

Glass Expansion RF Coils - represent the highest quality indesign and manufacturing

§§ WWHHYY TTOO CCHHAANNGGEE YYOOUURR RRFF CCOOIILLSS

• Regular replacement of corroded coils reduces the load on the RF generating system• Changing corroded coils increases enery transfer, resulting in a more robust plasma and

generally higher analytical line intensities.

§§ AADDVVAANNTTAAGGEE OOFF GGLLAASSSS EEXXPPAANNSSIIOONN RRFF CCOOIILLSS::

• High quality and consistent plating of our coils promotes extended coil life• Each coil is supplied on a plastic former ensuring correct dimensions and easier installation• Each coil is supplied in a special protective container to ensure correct dimensions are

maintained, and the coil arrives corrosion free• Correct alignment of the coil with respect to the torch body reduces de vitrification of the

outer tube• Reusable alignment tools ensure correct installation every time. Our CD with Do-It-Yourself

instructions saves time

§§ TTHHEE RROOLLEE OOFF TTHHEE RRFF CCOOIILLSS

The RF coil is the last component in the electrical system used to generate an Argon plasma. Being the lastcomponent, there is great importance placed on the coil for transferring RF energy to the plasma.There are three factors affecting the role of the RF Coil in transferring energy:

• Concentricity and alignment - these are very important in producing a correctly shaped plasma, whichconsistently needs to be located in the same position. The Glass Expansion RF Coil installation toolswith plastic coil supports make this possible every time.

• Correct dimensions - being part of the RF system, the coil dimensions are also important in the tuningof the circuit. Slight changes in dimensions can produce small changes in resistance or inductanceand are normally compensated for in the tuning circuitry of the system.

• Base metal/plating - the most efficient conductor of RF energy is pure silver followed by annealedcopper. There is very little difference in the conductivity of these materials but there is a great deal ofdifference in cost. Copper is used as the base material of all commercially available coils but differentmanufactures use different plating materials. Silver has the best conductance and gold the bestcorrosion resistance.

Being exposed to the environment of the torch box, the condition of the coil has a major effect on theefficiency of transferring energy to the plasma. The greater the corrosion, the larger the electrical energy thatis required to produce a plasma of the same power. This transfers undue stress on the rest of the electricalcomponents used in the RF system, possibly contributing to premature failure.

Page 55: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

55

There are three main areas that affect the transfer of energy from the plasma to the sample.

• Argon gas flow rates and quality.• The torch containing the plasma. The torch needs to be concentric and of the highest quality Quartz.

If the outer tube becomes devitrified, the transfer of energy is restricted due to losses incurred byheating on the surface of the outer tube, thereby reducing the available energy for the atoms.

• The RF generating system, including the coil. All RF systems available in commercial ICP instrumentsare capable of supplying the required power. The one component that is common to all instruments isthe coil. Each instrument has a different type of coil, with different dimensions and different number ofturns.

RF coils are one of a number of critical components needed to produce plasma. With the Glass Expansion RFcoils and installation tools it is now possible to replace your coil on a more regular basis without the cost of aservice visit. This ensures this part of the RF system continues to work in peak condition.

§§ BBEENNEEFFIITTSS OOFF MMAAIINNTTAAIINNIINNGG YYOOUURR RRFF CCOOIILLSS

The main problem with an RF coil is corrosion, whether from heat or chemical oxidation. Corrosion reducesthe efficiency of energy transfer to the plasma increasing the stress applied to other components in the RFgenerating system. In particular, the RF Power Tube or RF amplifying FET'shave to generate more power to deliver the same amount of energy to theplasma.

Coils are the transmitters of thisRF energy. The efficiency ofdifferent materials in conductingRF energy plays an important rolein the overall plasma efficiency.Metal oxides do not conduct RFas well as pure metal. In particularcopper sulfate is a very poorconductor, whereas silver oxidehas a much smaller effect onefficiency. The most RF efficientmetals are pure silver IAC (International Annealed Copper Standard) 105,annealed copper IAC 100, and gold IAC 74.

If heat is the biggest problem then the best way to deal with this is to use a coil that is plated in a highlyreflective material such as silver. Silver plating however does produce a tarnish appearance after a period ofuse. To obtain the best life out of a coil in this situation, the coil should be cleaned frequently with a tarnishremover. This will eventually lead to the removal of the silver plating. However, if the tarnish is not removed,excessive heat can build up due to higher absorption and lead to the plating flaking away from the coppertubing. This exposes bare copper areas that will deteriorate at a faster rate. Copper will oxidize much quicker,thereby leading to possible arcing between coils, and lower energy transfer to the plasma.

Chemical corrosion is best dealt with using a gold-plated coil. The plating process is critical in theperformance of the coil. Gold plating can produce porous coatings, which allow a chemical attack on thecopper tubing, thereby rendering the plating useless. The plating process used in the production of the GlassExpansion gold plated coils is designed to remove the porous effect yet still maintain the high purity plating. Intime, the gold plating will show signs of copper sulfate formation on the surface. This occurs due to coppermigration through the plating. For best performance these deposits should be removed using an abrasivemetal polish that is free of acid. Unfortunately once this starts to occur the migration will occur at a faster rateand the coil should be replaced.

Periodic cleaning of your coil will extend the lifetime and produce a more consistent plasma. This in turn willlead to better analytical results. It will also reduce stress on the RF generator.

Page 56: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

56

.

§§ AADDVVAANNTTAAGGEE OOFF GGLLAASSSS EEXXPPAANNSSIIOONN RRFF CCOOIILLSS

IntroductionGlass Expansion Coils are produced from the highest quality raw materials and plated using prescribedmethods to obtain maximum RF (Radio Frequency) transmission efficiency. There are numerous paperspublished on RF transmission with regard to conductor and coating resistance.

Plasma GenerationThe generation of a plasma is the result of complex RF circuit design. Many of the environmental problemsthat affect the coil have little effect on the operation of the RF generator, except that corrosion produces anadded load. In particular, corrosion of the coil has a significant effect on the performance and robustness ofthe plasma. Changing to a new coil reduces the load on the RF generator, since the current required toproduce the same level of power is reduced as the resistance of the coil is reduced. Hence, having a coil withlittle or no corrosion has a positive effect on the longevity of the PA (Power Amplifier) Tube or RF FET's (FieldEffect Transistor) due to the lower current required.

ConductivityThis can be explained by the conductivity of pure metals and oxides. Pure grade copper has an IACS(International Annealed Copper Standard) of 100, silver has an IACS of 105, and Gold has an IACS of 74. Inreferencing the ICAS system a higher IACS indicates higher conductivity. The following websites containinformation on the IACS for various metals.Twww.amm.com/index2.htm?/ref/conduct.HTMT Twww.eddy-current.com/condmat.htmT

The formation of an oxide on the surface of the coil reduces the conductivity of the coil and hence it'sperformance. Depending on the instrument and the control feedback system, this can be seen by a reductionin the intensity for an element of the same concentration over the life of the coil.

Corrosion ResistanceFrom a conductivity point, the best material to make a coil from would be pure silver but, due to the high costthis is impractical. Copper is the next best material, but the copper must be of an acceptable grade andcontain a minimum of contaminants. The copper used by Glass Expansion has a purity of 99.9% minimum.Once the base material is fixed, the environmental conditions under which the coil is placed need to beconsidered. The environmental conditions in the torch box include corrosive gases and high temperatures.These vary with instruments and plasma orientation (Radial or Axial). This leads to the use of plating of thecopper coils to help prevent unwanted corrosion, with the two most common materials being Silver and Gold.The plating process is vital to the conductivity of the coil. There are many different types of plating proceduresthat result in varying degrees of conductivity. The procedure used by Glass Expansion does not use additivebrighteners or corrosion inhibitors in the plating bath. This produces a dull coating, which is then manuallypolished to give a final bright appearance, resulting in a coil that retains the highest possible IACS rating.Coils should be continually cleaned to remove the build up of surface oxidation. The rate of corrosion is higherfor Copper, followed by Silver, then Gold. There are however, distinct advantages to using Silver. The platingprocess for Silver leaves a more even surface allowing fewer sites for chemical attack. The conductivity ofSilver is much higher than that of Gold, but Gold does offer a greater protection in more aggressiveenvironments.

BenefitsGlass Expansion recommends coils in Silver and Gold due to better conductivity and corrosion resistance.

• There are fewer problems with a silver-plated coil with arcing between windings, compared to thestandard copper coil. This in turn lengthens the life of the coil.

• Another advantage is our installation guide and alignment tools. These allow Do-It-Yourselfinstallations, saving the expense of a service engineer. These installation guides written on CompactDiscs, will show how to set up and align your torch and coil to the exact specifications. This reducestorch wear due to misaligned coils, especially in axial systems.

• All coils produced by Glass Expansion will be shipped with a coil former. This former holds the coil inthe correct dimensions during shipping and installation. The tool can also be used to check thedimensions from time to time, or to reset after an accidental knock.

• The packaging of Glass Expansion's coils will ensure that the coil arrives at the customer's site, in thecorrect dimensions.

Page 57: TORCHS NEBULIZERS SPRAY CHAMBERS VARIAN UK tecdev.pdf · 2009. 8. 5. · ACCESSORIES FOR ICP TYPE VARIAN TORCHS NEBULIZERS SPRAY CHAMBERS If you wish to use high quality products

57

§§ GGLLAASSSS EEXXPPAANNSSIIOONN IINNSSTTAALLLLAATTIIOONN TTOOOOLL KKIITT FFOORR CCOOIILLSS

Save the cost of a service call• Correct alignment of the RF coil with respect to the torch body reduces de vitrification on the outer

tube• Re-usable alignment tools are available separately, to ensure correct installation of the coil every time• Our easy to follow Do-it-Yourself installation instructions save you time, and the cost of a service call

All Kits Contain:• An Installation Tool• Required Spanner/s• Instructional CD

RF Coil Installation Kits:• All tools are designed specifically for each instrument• Designed to align coil to torch mounting bracket• DIY Instructions• Minimize ICP downtime