TOPSTO HEAD-OF-WALL - Tri-City Distribution · TOPSTO™ HEAD-OF-WALL ... Features and Benefits...

2
T OPS TO HEAD-OF-WALL INSULATION Description Submittal Sheet Features and Benefits Stops Fire – Formulated exactly the same as Thermafiber Safing Insulation, the mineral fiber composition of TopStop withstands sustained temperatures above 2000 o F, in accordance with ASTM E119. Systems are available for head-of-wall firestopping with up to 4-hour fire ratings. Stops Sound TopStop provides an effective acoustical barrier as well. It attenuates sound passage across the top of the wall. Saves Time – Uniform, pre-shaped TopStop boards eliminate field forming of insulation, while assuring a snug fit of material in the deck flutes. They increase worker productivity by reducing job-site fabrication and the uncertain- ty of installing the correct amount of Safing Insulation required in the many fire-stopping designs. Saves Material TopStop eliminates the waste produced by field cutting. And because TopStop’s edges are smooth, it also reduces the amount of smoke sealant required to complete installation. Environmentally Friendly TopStop is composed principally of recycled blast furnace slag from the steel indus- try, yielding a pre-consumer, recycle content of 85%. This material will not wick moisture, promote fungal or bac- terial growth, and will not contribute to corrosion of other materials. Sized to Fit – There are three standard sizes to fit common fluted roof decks or slabs. Special sizes and densities are available. Thermafiber ® TopStop Head-of-Wall Insulation is high-density mineral fiber insulation that has been shaped to fit the trapezoidal flutes typical of metal or concrete decking. The composition of these specialized insulation boards matches that of the Thermafiber Safing Insulation commonly called for in UL or OPL approved head-of-wall constructions. Insulation used for TopStop is UL and OPL Classified, and is approved for use in designs that otherwise call for Safing Insulation. Available in three common sizes of trapezoidal shaped boards, as well as standard forming strips, TopStop Insulation speeds the installation of floor-to-ceiling/roof deck firewalls. • Select TopStop size that fits within the flute space with the correct amount of compression of the insulation in all directions*. (Follow fire-stop assembly design specifications for correct density and amount of compression required.) • Cut insulation to a length sufficient to reach from the drywall surface plane on one side of the partition wall to the drywall surface plane on the other side. • Insert TopStop insulation in flute recesses so as to completely fill the area between the wall head and the roof deck. Add TopStop Strips where necessary to fill any gaps left between the top plate of the wall and any flute sur- faces. (Follow fire-stop assembly design specifications for correct density and amount of compression required.) • Apply smoke sealant as specified in the listed and tested design specification, and according to the smoke sealant manufacturer’s instructions. • Trim with metal or drywall components as called for in design specification. • Select TopStop size that fits within the flute space with the correct amount of compression of the insulation in all directions.* (Follow fire-stop assembly design specifications for correct density and amount of com- pression required.) • Cut insulation to a length sufficient to reach from the drywall surface plane on one side of the partition wall to the drywall surface plane on the other side. • Insert TopStop insulation in flute recess so as to completely fill the area above braced wall head and below the roof deck. Add wall top forming strip if required. (Follow fire-stop assembly design specifications for cor- rect density and amount of compression required.) • Apply smoke sealant as specified in the listed and tested design specification, and according to the smoke sealant manufacturer’s instructions. • Trim with metal or drywall components as called for in design specification. *Non-standard sizes and alternate densities are available on special order. Installation Wall Head Perpendicular to Flutes – Wall Head Parallel to Flutes –

Transcript of TOPSTO HEAD-OF-WALL - Tri-City Distribution · TOPSTO™ HEAD-OF-WALL ... Features and Benefits...

TOPSTO™ HEAD-OF-WALLINSULATION

Description

Submittal Sheet

Features and Benefits Stops Fire – Formulated exactly the same as Thermafiber Safing Insulation, the mineral fiber composition ofTopStop withstands sustained temperatures above 2000oF, in accordance with ASTM E119. Systems are availablefor head-of-wall firestopping with up to 4-hour fire ratings.

Stops Sound – TopStop provides an effective acoustical barrier as well. It attenuates sound passage across thetop of the wall.

Saves Time – Uniform, pre-shaped TopStop boards eliminate field forming of insulation, while assuring a snug fitof material in the deck flutes. They increase worker productivity by reducing job-site fabrication and the uncertain-ty of installing the correct amount of Safing Insulation required in the many fire-stopping designs.

Saves Material – TopStop eliminates the waste produced by field cutting. And because TopStop’s edges aresmooth, it also reduces the amount of smoke sealant required to complete installation.

Environmentally Friendly – TopStop is composed principally of recycled blast furnace slag from the steel indus-try, yielding a pre-consumer, recycle content of 85%. This material will not wick moisture, promote fungal or bac-terial growth, and will not contribute to corrosion of other materials.

Sized to Fit – There are three standard sizes to fit common fluted roof decks or slabs. Special sizes and densitiesare available.

Thermafiber® TopStop™ Head-of-Wall Insulation is high-density mineral fiber insulation that has been shaped tofit the trapezoidal flutes typical of metal or concrete decking. The composition of these specialized insulationboards matches that of the Thermafiber Safing Insulation commonly called for in UL or OPL approved head-of-wallconstructions. Insulation used for TopStop is UL and OPL Classified, and is approved for use in designs thatotherwise call for Safing Insulation. Available in three common sizes of trapezoidal shaped boards, as well asstandard forming strips, TopStop Insulation speeds the installation of floor-to-ceiling/roof deck firewalls.

• Select TopStop size that fits within the flute space with the correct amount of compression of the insulation in alldirections*. (Follow fire-stop assembly design specifications for correct density and amount of compressionrequired.)

• Cut insulation to a length sufficient to reach from the drywall surface plane on one side of the partition wall to thedrywall surface plane on the other side.

• Insert TopStop insulation in flute recesses so as to completely fill the area between the wall head and the roofdeck. Add TopStop Strips where necessary to fill any gaps left between the top plate of the wall and any flute sur-faces. (Follow fire-stop assembly design specifications for correct density and amount of compression required.)

• Apply smoke sealant as specified in the listed and tested design specification, and according to the smokesealant manufacturer’s instructions.

• Trim with metal or drywall components as called for in design specification.

• Select TopStop size that fits within the flute space with the correct amount of compression of the insulationin all directions.* (Follow fire-stop assembly design specifications for correct density and amount of com-pression required.)

• Cut insulation to a length sufficient to reach from the drywall surface plane on one side of the partition wallto the drywall surface plane on the other side.

• Insert TopStop insulation in flute recess so as to completely fill the area above braced wall head and belowthe roof deck. Add wall top forming strip if required. (Follow fire-stop assembly design specifications for cor-rect density and amount of compression required.)

• Apply smoke sealant as specified in the listed and tested design specification, and according to the smokesealant manufacturer’s instructions.

• Trim with metal or drywall components as called for in design specification.

*Non-standard sizes and alternate densities are available on special order.

Installation Wall HeadPerpendicular toFlutes –

Wall HeadParallel toFlutes –

TF687, Rev. 01/06© 2005, Thermafiber, Inc.Printed in U.S.A.

Submittal Sheet

Technical Data

TOPSTOP ™ HEAD-OF-WALL INSULATION

SpecificationCompliance

ProductCharacteristics

Good Design Practices 1. System performance following substitution of materials or compromise in assembly design cannot be certifiedand may result in failure of fire resistance or noise reduction performance under certain conditions. For exam-ple, substitution of low-density glass fiber insulation in place of the Thermafiber TopStop Insulation Board maycompromise fire protection at that point and therefore reduce the performance of the system.

2. Adjacent assemblies should be designed or selected to be of similar fire protection performance. Voids shouldbe filled or otherwise eliminated. Combined performance of adjacent systems will be close to that of the low-est performing element.

3. Penetrations for windows, HVAC, wiring, etc. must be sealed with an appropriate fire-stopping design.

4. See UL or Intertek Testing Services (OPL) Design for specific design criteria and list of approved smokesealant manufacturers.

For further information aboutthese products, including nonstan-dard sizes, contact Thermafiber,Inc. at 888-TFIBER1 (888-834-2371).

TrademarksTHERMAFIBER and THE NAME INMINERAL WOOL are registeredtrademarks of Thermafiber, Inc.TopStop is a trademark ofThermafiber, Inc.

NoteProducts described herein maynot be available in all geographicmarkets. Consult your Thermafibersales representative for furtherinformation. All product and system information containedherein is believed to be accurateat the time of publication.Thermafiber, Inc. reserves theright to add, alter or discontinueproducts without notice. For thelatest information on any product,consult your Thermafiber salesrepresentative or visit our website,www.thermafiber.com.

NoticeThermafiber, Inc. will not be liablefor incidental and consequentialdamages, directly or indirectlysustained, nor for any loss causedby application of these goods notin accordance with current printedinstructions or for other than theintended use. Thermafiber’s liabili-ty is expressly limited to replace-ment of defective goods. Anyclaim shall be deemed waivedunless made in writing to us with-in thirty (30) days from date it was or reasonably should havebeen discovered.

Safety First!Follow good safety and industrialhygiene practices while handlingand installing products and sys-tems. Take necessary precautionsand wear the appropriate personalprotective equipment as needed.Read material safety data sheets(MSDS) and related literature onproducts before specificationand/or installation.

Material Safety Data Sheet islocated on Thermafiber websitewww.thermafiber.com.

Health AspectsFor health and safety information,see Material Safety Data Sheets(MSDS) and North AmericanInsulation ManufacturersAssociation (NAIMA) Health andSafety Facts for Rock and SlagWool Insulation, Document #63.

3711 West Mill StreetWabash, IN 46992888-TFIBER1 (834-2371)www.thermafiber.com

™ THERMAFIBER MADE FROMRECYCLED MATERIALS

Job Name

Contractor DateSubmittal Approvals

MADE IN USA

Product Board Top Bottom Bevel Board Nominal Flame Spread/ Pieces/ Lineal Ft./Number Thickness Width Width Cut Length Density* k-Value Smoke Developed Carton Carton

TSZ-1 1-1/2” 3-1/2” 4-1/2” 108º 36” 6.0 lb./ft.3 0.24 0/0 50 150

TSZ-2 2” 4-1/2” 5-1/2” 104º 36” 6.0 lb./ft.3 0.24 0/0 32 96

TSZ-3 3” 5” 7” 108º 36” 6.0 lb./ft.3 0.24 0/0 16 48

TSF-A2 1-1/4” 2” 2” 90º 36” 6.0 lb./ft.3 0.24 0/0 140 420

TSF-A4 1-1/4” 4” 4” 90º 36” 6.0 lb./ft.3 0.24 0/0 70 210

TSF-B2 5/8” 2” 2” 90º 36” 6.0 lb./ft.3 0.24 0/0 252 756

TSF-B4 5/8” 4” 4” 90º 36” 6.0 lb./ft.3 0.24 0/0 126 378

*4.0 pcf or 8.0 pcf nominal density is available on special order.

Test Standard ResultSurface Burning Characteristics UL 723 Flame Spread = 0

ASTM E 84 Smoke Developed = 0Thermal Performance ASTM C 518 See Technical Data

ASTM C 553 Adsorb < 1% moisture by weight & volumeASTM C 612, HH-I-558B Type 1A, 1B & 2ASTM C 665, HH-I-521F Type 1

Combustibility NFPA 220 Rated non-combustible as tested per ASTM E 136New York City Board of 39-74-SM ApprovedStandards and Appeals MEA-209-82M, Vol. II

108º 104º 108º

41⁄2" 51⁄2" 7"

5"

2" 3"

2 or 4"

5⁄8" or 11⁄4"

41⁄2"31⁄2"

11⁄2"

TSZ-1 TSZ-2 TSZ-3 TSF-A2, A4, B2, B4

3711 Mill Street Wabash, IN 46992 888-TFIBER1 (834-2371)(260) 563-2111www.thermafiber.com

TF687/Rev. 09/08Copyright 2008, Thermafiber, Inc. Printed in U.S.A.

TTHHEERRMMAAFFIIBBEERR MMAADDEE FFRROOMMRREECCYYCCLLEEDD MMAATTEERRIIAALLSS