TOPSOLAR® PV AL 1500 V...TOPSOLAR® PV AL 1500 V Aluminium PV cable. BASED ON: IEC 60502-1 / NFC...
Transcript of TOPSOLAR® PV AL 1500 V...TOPSOLAR® PV AL 1500 V Aluminium PV cable. BASED ON: IEC 60502-1 / NFC...
TOPSOLAR® PVAL 1500 VAluminium PV cable.BASED ON: IEC 60502-1 / NFC 32-321 / EN 50618 (parcial)
DESIGN
ConductorAluminium, class 2 based on EN 60228 and IEC 60228.
InsulationCross-linked polyethylene (XLPE).
Outer sheathSpecial flexible UV resistant PVC, Black colour.
APPLICATIONS
DC Feeder Aluminium 1500 PV cable is suitable for all types of underground andopen air solar installations. This cable is recommended for connections betweenstring boxes and photovoltaic inverters in large scale rooftops or ground farms.
• Solar PV installations. • Heavy impact and armoured versions also available.
LSHF ALSOAVAILABLE
More information at: www.topcable.com
TOPS
OLA
R® P
V AL
1500
VSO
LAR
CABL
ESEN2020ED001
For more information: www.topcable.com
TOPS
OLA
R® P
V AL
1500
VSO
LAR
CABL
ESEN2020ED001
FEATURES
Electrical performanceLow voltage 1,5/1,5 (1,8) kV DC based on EN 50618. 1,8/3 (3,6) kV AC based on IEC 60502-1.
Based onIEC 60502-1 / NFC 32-321 / EN 50618 (parcial).
Standards and approvalsCE / RoHS.
CPR (Construction Products Regulation)Eca.
Thermal performanceMaximum service temperature: 90°C.Maximum short-circuit temperature: 250°C (max. 5 s).Minimum service temperature: -40°C (fixed and protected installations).
Fire performanceFlame non-propagation based on EN 60332-1 and IEC 60332-1.Reaction to fire CPR: Eca, according to EN 50575.Reduced halogen emission. Chlorine <15%.
Mechanical performanceMinimum bending radius: x5 cable diameter.Impact resistance: AG2 Medium severity.
Chemical performanceChemical resistance: Good. Grease & mineral oils resistance: Good.
UV UV Resistant based on EN 50618.03 Ozone resistant based on EN 50618.
Water performanceWater presence: AD8 submerged.
OtherMeter by meter marking.Estimated lifetime: 30 years based on UNE-EN 60216-2.
Optional: rodent proof and termite proof.
Installation conditionsOpen Air.Buried.In conduit.
TOPSOLAR® PVH1Z2Z2-K