DELTA®-DRY & LATH Manufactured stone Concrete foundation wall Insulation Sill plate gasket Exterior sheathing WRB installed as per manufacturer's specifications Scratch coat Mortar Bottom of wall detail Bottom of window detail Top of window detail Top of wall detail DELTA®-DRY & LATH TITLE: 4655 DELTA WAY BEAMSVILLE, ON. L0R 1B4 CANADA 1-888-433-5824 or 1-905-563-3255 SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THAT THE INFORMATION IN THIS DETAIL DRAWING IS ACCURATE. DORKEN SYSTEMS INC. CANNOT ACCEPT RESPONSIBILITY FOR ANY ERRORS OR OVERSIGHTS IN THE USE OF THIS MATERIAL OR IN THE PREPARATION OF ARCHITECTURAL OR ENGINEERING PLANS. THE DESIGN PROFESSIONAL MUST RECOGNIZE THAT NO DESIGN DETAIL CAN SUBSTITUTE FOR EXPERIENCED ENGINEERING AND PROFESSIONAL JUDGEMENT. DRAWN BY: Krzysztof Apriasz C. Tech., CPHC® DELTA®-DRY & LATH RAINSCREEN APPLICATION WITH MANUFACTURED STONE File Name: DRY1_LATH Date: November 27, 2108 **For proper performance of DELTA®-DRY & LATH ensure top and bottom remain open to allow ventilation and drainage** NOTE: WRB (WATER-RESISTIVE BARRIER) TO BE INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS

Transcript of Top of window detail - dorken.com · the information in this detail drawing is accurate. dorken...

Page 1: Top of window detail - dorken.com · the information in this detail drawing is accurate. dorken systems inc. cannot accept responsibility for any errors or oversights in the use of

DELTA®-DRY & LATH

Manufactured

stone

Concrete

foundation wall

Insulation

Sill plate gasket

Exterior sheathing

WRB installed as per

manufacturer's specifications

Scratch coat

Mortar

Bottom of wall detail

Bottom of window detail

Top of window detail

Top of wall detail

DELTA®-DRY & LATH

TITLE:

4655 DELTA WAY BEAMSVILLE, ON. L0R 1B4 CANADA

1-888-433-5824 or 1-905-563-3255

SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THAT

THE INFORMATION IN THIS DETAIL DRAWING IS

ACCURATE. DORKEN SYSTEMS INC. CANNOT ACCEPT

RESPONSIBILITY FOR ANY ERRORS OR OVERSIGHTS IN

THE USE OF THIS MATERIAL OR IN THE PREPARATION OF

ARCHITECTURAL OR ENGINEERING PLANS. THE DESIGN

PROFESSIONAL MUST RECOGNIZE THAT NO DESIGN

DETAIL CAN SUBSTITUTE FOR EXPERIENCED

ENGINEERING AND PROFESSIONAL JUDGEMENT.

DRAWN BY: Krzysztof Apriasz C. Tech., CPHC®

DELTA®-DRY & LATH RAINSCREEN

APPLICATION WITH

MANUFACTURED STONE

File Name: DRY1_LATHDate: November 27, 2108

**For proper performance of DELTA®-DRY & LATH ensure top and bottom remain open to allow ventilation and drainage**

NOTE:

WRB (WATER-RESISTIVE BARRIER) TO BE

INSTALLED AS PER MANUFACTURER'S

SPECIFICATIONS

Page 2: Top of window detail - dorken.com · the information in this detail drawing is accurate. dorken systems inc. cannot accept responsibility for any errors or oversights in the use of

Min.

3

8

" gap between flashings

for ventilation

DELTA®-DRY & LATH

Scratch coat

Mortar

Manufactured

stone

WRB

Option 1.

J-trim

(metal preferred)

Flashing w/ drip edge

(metal preferred)

DELTA®-BUG SCREEN

TITLE:

4655 DELTA WAY BEAMSVILLE, ON. L0R 1B4 CANADA

1-888-433-5824 or 1-905-563-3255

SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THAT

THE INFORMATION IN THIS DETAIL DRAWING IS

ACCURATE. DORKEN SYSTEMS INC. CANNOT ACCEPT

RESPONSIBILITY FOR ANY ERRORS OR OVERSIGHTS IN

THE USE OF THIS MATERIAL OR IN THE PREPARATION OF

ARCHITECTURAL OR ENGINEERING PLANS. THE DESIGN

PROFESSIONAL MUST RECOGNIZE THAT NO DESIGN

DETAIL CAN SUBSTITUTE FOR EXPERIENCED

ENGINEERING AND PROFESSIONAL JUDGEMENT.

DRAWN BY:

DATE: November 27, 2108

SCALE: NTS

FILE NAME:

DRY&LATH_B1

DELTA®-DRY LATH RAINSCREEN APPLICATION

WITH MANUFACTURED STONE BOTTOM OF WALL

DETAIL OPTION 1

Krzysztof Apriasz C. Tech., CPHC®

**For proper performance of DELTA®-DRY & LATH ensure top and bottom remain open to allow ventilation and drainage**

NOTE:

WRB (WATER-RESISTIVE BARRIER) TO BE

INSTALLED AS PER MANUFACTURER'S

SPECIFICATIONS

Page 3: Top of window detail - dorken.com · the information in this detail drawing is accurate. dorken systems inc. cannot accept responsibility for any errors or oversights in the use of

Min.

3

8

" gap between flashings

for ventilation

DELTA®-DRY & LATH

Scratch coat

Mortar

Manufactured

stone

WRB

Option 2.

Weep screed

(metal preferred)

Flashing w/ drip edge

(metal preferred)

DELTA®-BUG SCREEN

TITLE:

4655 DELTA WAY BEAMSVILLE, ON. L0R 1B4 CANADA

1-888-433-5824 or 1-905-563-3255

SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THAT

THE INFORMATION IN THIS DETAIL DRAWING IS

ACCURATE. DORKEN SYSTEMS INC. CANNOT ACCEPT

RESPONSIBILITY FOR ANY ERRORS OR OVERSIGHTS IN

THE USE OF THIS MATERIAL OR IN THE PREPARATION OF

ARCHITECTURAL OR ENGINEERING PLANS. THE DESIGN

PROFESSIONAL MUST RECOGNIZE THAT NO DESIGN

DETAIL CAN SUBSTITUTE FOR EXPERIENCED

ENGINEERING AND PROFESSIONAL JUDGEMENT.

DRAWN BY:

DATE: November 27, 2018

SCALE: NTS

FILE NAME:

DRY&LATH_B2

DELTA®-DRY & LATH RAINSCREEN APPLICATION

WITH MANUFACTURED STONE BOTTOM OF WALL

DETAIL OPTION 2

Krzysztof Apriasz C. Tech., CPHC®

**For proper performance of DELTA®-DRY & LATH ensure top and bottom remain open to allow ventilation and drainage**

NOTE:

WRB (WATER-RESISTIVE BARRIER) TO BE

INSTALLED AS PER MANUFACTURER'S

SPECIFICATIONS

Page 4: Top of window detail - dorken.com · the information in this detail drawing is accurate. dorken systems inc. cannot accept responsibility for any errors or oversights in the use of

Min.

3

8

" gap between flashings

for ventilation

DELTA®-DRY & LATH

Scratch coat

Mortar

Manufactured

stone

Molding piece 2" min. leg

depending on local

wind conditions

WRB

Option 1.

Wood blocking

cut to fit on site

DELTA®-BUG SCREEN

TITLE:

4655 DELTA WAY BEAMSVILLE, ON. L0R 1B4 CANADA

1-888-433-5824 or 1-905-563-3255

SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THAT

THE INFORMATION IN THIS DETAIL DRAWING IS

ACCURATE. DORKEN SYSTEMS INC. CANNOT ACCEPT

RESPONSIBILITY FOR ANY ERRORS OR OVERSIGHTS IN

THE USE OF THIS MATERIAL OR IN THE PREPARATION OF

ARCHITECTURAL OR ENGINEERING PLANS. THE DESIGN

PROFESSIONAL MUST RECOGNIZE THAT NO DESIGN

DETAIL CAN SUBSTITUTE FOR EXPERIENCED

ENGINEERING AND PROFESSIONAL JUDGEMENT.

DRAWN BY:

DATE: November 27, 2018

SCALE: NTS

FILE NAME:

DRY&LATH_T1

DELTA®-DRY & LATH RAINSCREEN APPLICATION

WITH MANUFACTURED STONE TOP OF WALL

DETAIL OPTION 1

Krzysztof Apriasz C. Tech., CPHC®

**For proper performance of DELTA®-DRY & LATH ensure top and bottom remain open to allow ventilation and drainage**

NOTE:

WRB (WATER-RESISTIVE BARRIER) TO BE

INSTALLED AS PER MANUFACTURER'S

SPECIFICATIONS

Page 5: Top of window detail - dorken.com · the information in this detail drawing is accurate. dorken systems inc. cannot accept responsibility for any errors or oversights in the use of

Min.

3

8

" gap between flashings

for ventilation

DELTA®-DRY & LATH

Scratch coat

Mortar

Manufactured

stone

Aluminum flashing 2" min.leg

depending on local

wind conditions

WRB

Option 2. "L" flashing

DELTA®-BUG SCREEN

TITLE:

4655 DELTA WAY BEAMSVILLE, ON. L0R 1B4 CANADA

1-888-433-5824 or 1-905-563-3255

SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THAT

THE INFORMATION IN THIS DETAIL DRAWING IS

ACCURATE. DORKEN SYSTEMS INC. CANNOT ACCEPT

RESPONSIBILITY FOR ANY ERRORS OR OVERSIGHTS IN

THE USE OF THIS MATERIAL OR IN THE PREPARATION OF

ARCHITECTURAL OR ENGINEERING PLANS. THE DESIGN

PROFESSIONAL MUST RECOGNIZE THAT NO DESIGN

DETAIL CAN SUBSTITUTE FOR EXPERIENCED

ENGINEERING AND PROFESSIONAL JUDGEMENT.

DRAWN BY:

DATE: November 27, 2018

SCALE: NTS

FILE NAME:

DRY&LATH_T2

DELTA®-DRY & LATH RAINSCREEN APPLICATION

WITH MANUFACTURED STONE TOP OF WALL

DETAIL OPTION 2

Krzysztof Apriasz C. Tech., CPHC®

**For proper performance of DELTA®-DRY & LATH ensure top and bottom remain open to allow ventilation and drainage**

NOTE:

WRB (WATER-RESISTIVE BARRIER) TO BE

INSTALLED AS PER MANUFACTURER'S

SPECIFICATIONS

Page 6: Top of window detail - dorken.com · the information in this detail drawing is accurate. dorken systems inc. cannot accept responsibility for any errors or oversights in the use of

WRB

DELTA®-DRY & LATH

Scratch coat

Mortar

Manufactured

stone

Flashing w/ drip edge

(metal preferred)

Min.

3

8

" gap between

flashing for ventilation

WRB

DELTA®-DRY

& LATH

Scratch coat

Mortar

Manufactured

stone

Sealant

Backer rod

Around window and door

openings install WRB as

per manufacturer's specifications

TOP OF WINDOW DETAIL BOTTOM OF WINDOW DETAIL

DELTA®-BUG SCREEN

TITLE:

4655 DELTA WAY BEAMSVILLE, ON. L0R 1B4 CANADA

1-888-433-5824 or 1-905-563-3255

SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THAT

THE INFORMATION IN THIS DETAIL DRAWING IS

ACCURATE. DRKEN SYSTEMS INC. CANNOT ACCEPT

RESPONSIBILITY FOR ANY ERRORS OR OVERSIGHTS IN

THE USE OF THIS MATERIAL OR IN THE PREPARATION OF

ARCHITECTURAL OR ENGINEERING PLANS. THE DESIGN

PROFESSIONAL MUST RECOGNIZE THAT NO DESIGN

DETAIL CAN SUBSTITUTE FOR EXPERIENCED

ENGINEERING AND PROFESSIONAL JUDGEMENT.

DRAWN BY:

November 27, 2108

SCALE: NTS

FILE NAME:

DRY&LATH_W1

DELTA®-DRY & LATH RAINSCREEN APPLICATION

WITH MANUFACTURED STONE WINDOW DETAIL

Krzysztof Apriasz C. Tech., CPHC®

**For proper performance of DELTA®-DRY & LATH ensure top and bottom remain open to allow ventilation and drainage**

NOTE:

WRB (WATER-RESISTIVE BARRIER) TO BE

INSTALLED AS PER MANUFACTURER'S

SPECIFICATIONS

Page 7: Top of window detail - dorken.com · the information in this detail drawing is accurate. dorken systems inc. cannot accept responsibility for any errors or oversights in the use of

Conventional stucco

finish

Scratch coat

DELTA®-DRY &

LATH

WRB

Exterior sheathing

Manufactured

stone

Scratch coat

DELTA®-DRY &

LATH

Backer rod

Sealant

Min.

3

8

" gap for

ventilation

DELTA®-DRY & LATH

J-trim

(metal preferred)

Flashing w/ drip edge

(metal preferred)

Min.

3

8

" gap for

ventilation

Flashing w/ drip edge

(metal preferred)

J-trim

(metal preferred)

DELTA®-DRY & LATH

STUCCO TO STUCCO

TYPICAL TRANSITION

MANUFACTURED STONE TO

STUCCO TYPICAL TRANSITION

4" min.

4" min.

2" min.

2" min.

DELTA®-BUG SCREEN

DELTA®-BUG SCREEN

TITLE:

4655 DELTA WAY BEAMSVILLE, ON. L0R 1B4 CANADA

1-888-433-5824 or 1-905-563-3255

SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THAT

THE INFORMATION IN THIS DETAIL DRAWING IS

ACCURATE. DORKEN SYSTEMS INC. CANNOT ACCEPT

RESPONSIBILITY FOR ANY ERRORS OR OVERSIGHTS IN

THE USE OF THIS MATERIAL OR IN THE PREPARATION OF

ARCHITECTURAL OR ENGINEERING PLANS. THE DESIGN

PROFESSIONAL MUST RECOGNIZE THAT NO DESIGN

DETAIL CAN SUBSTITUTE FOR EXPERIENCED

ENGINEERING AND PROFESSIONAL JUDGEMENT.

DRAWN BY:

DATE: November 27, 2018

SCALE: NTS

FILE NAME:

DRY&LATH_TRANSITION1

TYPICAL WALL TRANSITION DETAILS

OPTION 2.

Krzysztof Apriasz C. Tech., CPHC®

**For proper performance of DELTA®-DRY & LATH ensure top and bottom remain open to allow ventilation and drainage**

NOTE:

WRB (WATER-RESISTIVE BARRIER) TO BE

INSTALLED AS PER MANUFACTURER'S

SPECIFICATIONS

Page 8: Top of window detail - dorken.com · the information in this detail drawing is accurate. dorken systems inc. cannot accept responsibility for any errors or oversights in the use of

Conventional stucco

finish

Scratch coat

Fabric mortar screen

DELTA®-DRY &

LATH

WRB

Exterior sheathing

Manufactured

stone

Scratch coat

WRB

DELTA®-DRY &

LATH

Backer rod

Sealant

Min.

3

8

" gap for

ventilation

DELTA®-DRY & LATH

J-trim

(metal preferred)

Flashing w/ drip edge

(metal preferred)

Min.

3

8

" gap for

ventilation

Flashing w/ drip edge

(metal preferred)

J-trim

(metal preferred)

DELTA®-DRY & LATH

STUCCO TO STUCCO

TYPICAL TRANSITION

MANUFACTURED STONE TO

STUCCO TYPICAL TRANSITION

4" min.

4" min.

2" min.

2" min.

DELTA®-BUG SCREEN

DELTA®-BUG SCREEN

TITLE:

4655 DELTA WAY BEAMSVILLE, ON. L0R 1B4 CANADA

1-888-433-5824 or 1-905-563-3255

SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THAT

THE INFORMATION IN THIS DETAIL DRAWING IS

ACCURATE. DORKEN SYSTEMS INC. CANNOT ACCEPT

RESPONSIBILITY FOR ANY ERRORS OR OVERSIGHTS IN

THE USE OF THIS MATERIAL OR IN THE PREPARATION OF

ARCHITECTURAL OR ENGINEERING PLANS. THE DESIGN

PROFESSIONAL MUST RECOGNIZE THAT NO DESIGN

DETAIL CAN SUBSTITUTE FOR EXPERIENCED

ENGINEERING AND PROFESSIONAL JUDGEMENT.

DRAWN BY:

DATE: November 27, 2108

SCALE: NTS

FILE NAME:

DRY&LATH_TRANSITION2

TYPICAL TRANSITION DETAIL

OPTION 2.

Krzysztof Apriasz C. Tech., CPHC®

**For proper performance of DELTA®-DRY & LATH ensure top and bottom remain open to allow ventilation and drainage**

NOTE:

WRB (WATER-RESISTIVE BARRIER) TO BE

INSTALLED AS PER MANUFACTURER'S

SPECIFICATIONS

Page 9: Top of window detail - dorken.com · the information in this detail drawing is accurate. dorken systems inc. cannot accept responsibility for any errors or oversights in the use of

Min.

3

8

" gap between flashings

for ventilation

DELTA®-DRY & LATH

Scratch coat

Mortar

Manufactured

stone

WRB

J-trim

(metal preferred)

Exterior sheathing

Copper shield

(optional)

DELTA®-DRAIN

Waterproofing membrane

Slo

ped g

rade

DELTA®-BUG SCREEN

TITLE:

4655 DELTA WAY BEAMSVILLE, ON. L0R 1B4 CANADA

1-888-433-5824 or 1-905-563-3255

SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THAT

THE INFORMATION IN THIS DETAIL DRAWING IS

ACCURATE. DORKEN SYSTEMS INC. CANNOT ACCEPT

RESPONSIBILITY FOR ANY ERRORS OR OVERSIGHTS IN

THE USE OF THIS MATERIAL OR IN THE PREPARATION OF

ARCHITECTURAL OR ENGINEERING PLANS. THE DESIGN

PROFESSIONAL MUST RECOGNIZE THAT NO DESIGN

DETAIL CAN SUBSTITUTE FOR EXPERIENCED

ENGINEERING AND PROFESSIONAL JUDGEMENT.

DRAWN BY: Krzysztof Apriasz C. Tech., CPHC®

MANUFACTURED STONE BELOW GRADE

WITH DELTA®-DRY & LATH

File Name: DRY&LATH1_MSBDate: November 27, 2018

**For proper performance of DELTA®-DRY & LATH ensure top and bottom remain open to allow ventilation and drainage**

NOTE:

WRB (WATER-RESISTIVE BARRIER) TO BE

INSTALLED AS PER MANUFACTURER'S

SPECIFICATIONS