1 Utah State University – Spring 2012 STAT 5570: Statistical Bioinformatics Notes 5.1 1 Tools for Preprocessing Mass Spectrometry Data

description

Tools for Preprocessing Mass Spectrometry Data. Utah State University – Spring 2012 STAT 5570: Statistical Bioinformatics Notes 5.1. 1. Outline. Introduction to Mass Spectrometry Issues in Preprocessing Recent Software Tools Sample Analysis Misc. Notes. 2. Mass Spectrometry. - PowerPoint PPT Presentation

Transcript of Tools for Preprocessing Mass Spectrometry Data

Page 1: Tools for Preprocessing  Mass Spectrometry Data

1

Utah State University – Spring 2012

STAT 5570: Statistical Bioinformatics

Notes 5.11

Tools for Preprocessing Mass Spectrometry Data

Page 2: Tools for Preprocessing  Mass Spectrometry Data

2

Outline

2

Introduction to Mass Spectrometry

Issues in PreprocessingRecent Software ToolsSample AnalysisMisc. Notes

Page 3: Tools for Preprocessing  Mass Spectrometry Data

3

Mass Spectrometry

3

Technology to assess composition of a complex mixture of proteins and metabolites

MALDI: matrix-assisted laser desorption and ionizationBiological sample mixed with a crystal-

forming energy-absorbing matrix (EAM)Mixture crystallizes on metal plate (chip

or slide)In a vacuum, plate hit with pulses from

laserMolecules in matrix are released,

producing a gas plume of ionsElectric field accelerates ions into a flight

tube towards a detector, recording time of flight

(Dijkstra 2008; Coombes et al. 2007)

Page 4: Tools for Preprocessing  Mass Spectrometry Data

4

SELDI-TOFSurface-enhanced laser desorption

and ionizationSpecial case of MALDICiphergen (Bio-Rad) ProteinChip:

eight-spot arraySurface of metal plate chemically

modified to favor particular classes of proteins

(Coombes et al. 2007; Tibshirani et al. 2004; image from www.pasteur.fr)

Page 5: Tools for Preprocessing  Mass Spectrometry Data

5

Within narrow time intervals (1-4 nanoseconds), detector records the number of particles: time of flight

Animation

SELDI ProteinChip Technology

(Coombes et al. 2007; Tibshirani et al. 2004; image from Yasui et al. 2003)

www.learner.org/channel/courses/biology/archive/animations/hires/a_proteo3_h.html

Page 6: Tools for Preprocessing  Mass Spectrometry Data

6

Other Separation TechniquesGas Chromatography (GC)

also called gas-liquid chromatographyLiquid Chromatography (LC)

also called high performance liquid chromatography (HPLC)

Common Features:molecules pass through a

chromatographic columntime of passage depends on molecule

characteristicscoupled with a detector to record time-of-

flight and report mass spectra (GC-MS, LC-MS)

Successful separation reduces number of overlapping peaks

(Dijkstra 2008)

Page 7: Tools for Preprocessing  Mass Spectrometry Data

7

Each molecule has a mass (m) and a charge (z)

The m/z ratio affects the molecule’s velocity in the flight tube, and consequently its time of flight t

Based on the law of energy conservation:

Parameters t0, α, and β estimated using [instrument-specific] calibration data; V is electronvolt unit of energy

Mass-to-charge (m/z) ratio

20ttV

zm

(Dijkstra 2008)

Page 8: Tools for Preprocessing  Mass Spectrometry Data

8

Sample spectra

0 5000 10000 20000 30000

2000

6000

1000

014

000

Spectrum

m/z

Inte

nsity

1000 1200 1400 1600 1800 2000

8000

1000

012

000

1400

0

Partial Spectrum

m/z

Inte

nsity

Page 9: Tools for Preprocessing  Mass Spectrometry Data

9

Two-Step Analysis Approach1. Preprocess Mass Spectrometry Data

Identify peak locations and quantify each peak in each spectrum

(1.5). Identify ComponentsDetermine which molecule (protein,

metabolite) caused each peak2. Test for Differences

Similar to differential expression of genes between treatment and control

(Morris et al. 2005; Coombes et al. 2007)

Page 10: Tools for Preprocessing  Mass Spectrometry Data

10

Preprocessing IssuesCalibrationFiltering / Denoise SpectraDetrend / Remove Baseline from

SpectraNormalization of Multiple SpectraPeak DetectionPeak AlignmentPeak Quantification

(Coombes et al. 2007)

Page 11: Tools for Preprocessing  Mass Spectrometry Data

11

CalibrationMapping observed time-of-flight to m/z valuesExperimentally:

create a sample containing a small number of [mass known] proteins

obtain spectrum from sample using the mass spectrometry instrument

Parameters t0, α, and β estimated using [instrument-specific] calibration data:

Also refers to finding common m/z values for multiple spectra (msPrepare function uses linear interpolation)

(Dijkstra 2008; Coombes et al. 2007; Morris et al. 2005)

20ttV

zm

Page 12: Tools for Preprocessing  Mass Spectrometry Data

12

Preprocessing StrategiesChoices:

How to approach each preprocessing issue

Order of addressing each preprocessing issue

Some available softwareCommercial – usually manufacturer-

specificR Packages

msProcess (CRAN: Lixin Gong) – examples used here

PROcess (Bioconductor: Xiaochun Li)caMassClass (CRAN: Jarek Tuszynski)MassSpecWavelet (Bioconductor: Pan

Du)FTICRMS (CRAN: Don Barkauskas)RProteomics (caBIG: Rich Haney)

Page 13: Tools for Preprocessing  Mass Spectrometry Data

13

Sample Data and CodeReproducibility of results in these

slidesR code included in these slidesR Package msBreast: dataset of 96

protein mass spectra generated from a pooled sample of nipple aspirate fluid (NAF) from healthy breasts and breasts with cancer

Observations with m/z below 950 eliminatedjust noise from matrix moleculesthese observations can be just saturation (too many ions hitting the detector so it can’t count them)

(Coombes et al. 2003; Coombes et al. 2005)

Page 14: Tools for Preprocessing  Mass Spectrometry Data

14

Sample Data FormatAn msSet object with a numeric

vector of m/z values, a factor vector of spectra types, and a numeric matrix of intensities :columns: 96 samples (spectra)rows: 15466 m/z values

(R code chunk 1)

Page 15: Tools for Preprocessing  Mass Spectrometry Data

15

Visualize Two Spectraused for all sample plots here unless otherwise noted

(R code chunk 2)

Page 16: Tools for Preprocessing  Mass Spectrometry Data

16

Filtering / Denoising Spectra

Spectra contains random noiseTechnical sources of variability

chemicalelectronic

Remove by smoothing spectra

Smoothing options:Wavelet shrinkage (default)Multiresolution decomposition (MRD)

Robust running median(Coombes et al. 2007)

Page 17: Tools for Preprocessing  Mass Spectrometry Data

17

Here, MRD = original(not shown)

(R code chunk 3)

Page 18: Tools for Preprocessing  Mass Spectrometry Data

18

Denoising – what do options do?

Wavelet shrinkage – discrete wavelet transformcalculate DWT (linear combination of

functions)shrink wavelet coefficients

(calculated noise threshold and specified shrinkage function )

invert the DWT to get denoised version of series

Multiresolution decomposition (noise ≈ 0 here)calculate DWTinvert componentssum ‘non-noisy’ components

Robust running medianTukey’s 3RS3R:

repeat running medians of length 3 to convergence

split horizontal stretches of length 2 or 3repeat running medians of length 3 to

convergence ‘twiced’: add smoothed residuals to the

smoothed values

Page 19: Tools for Preprocessing  Mass Spectrometry Data

19

Local Noise EstimationMay be interested in “where” noise

islocal noise = (smoothed noise)Smoothing options:

spline (default) – cubic spline interpolation

supsmu – Friedman’s “super smoother”

ksmooth – kernel regression smoother

loess – local polynomial regression smoother

mean – moving average

Page 20: Tools for Preprocessing  Mass Spectrometry Data

20 (R code chunk 4)

Page 21: Tools for Preprocessing  Mass Spectrometry Data

21

Detrend / Baseline SubtractionTechnical artifacts of mass

spectrometry data: “a cloud of matrix

molecules hitting the detector” at early times

detector [or ion] overloadchemical noise in EAM

No model for full generalizability of baseline, only required to be smooth

Observed signal at time t:0 5000 10000 20000 30000

2000

6000

1000

014

000

Spectrum

m/z

Inte

nsity

(Li et al. 2005; Morris et al. 2005; Coombes et al. 2007)

)()()()( ttSNtBtf noisebaseline normalization

factor true signal

Page 22: Tools for Preprocessing  Mass Spectrometry Data

22

Baseline Optionsloess (default) – local

polynomial regression smoother

spline – cublic spline interpolation

supsmu – Friedman’s super-smoother

approx – linear or constant interpolation of local minima

monotone – cumulative minimum

mrd (multiresolution decomposition)

errors with all these (can avoid); can give negative signalcan give negative signal

(Coombes et al. 2005; Randolph & Yasui 2006)

Page 23: Tools for Preprocessing  Mass Spectrometry Data

23

(check tuning / smoothing parameters in these options)

(R code chunk 5)

Page 24: Tools for Preprocessing  Mass Spectrometry Data

24

Intensity NormalizationMake comparisons of multiple spectra

meaningfulBasic assumption:

total amount of protein desorbed from sample plate should be the same for all samples

amount of protein desorbed: TIC (total ion current)

Normalization options (Yi = vector of intensities)tic (default) – total ion current

all spectra have same area under curvefor spectra i:

snv – standard normal variateall spectra have same mean and

standard deviationfor spectra i:

iiii YsummedianYsumYY /'

iiii YsdYmeanYY /'

(Morris et al. 2005; Randolph & Yasui 2006)

Page 25: Tools for Preprocessing  Mass Spectrometry Data

25 (R code chunk 6)

Page 26: Tools for Preprocessing  Mass Spectrometry Data

26

Normalization and QualitySpectra with extreme

normalization factors may suggest poor quality

May need to eliminate some spectra (or arrays)

(Bio-Rad 2008) (R code chunk 7)

Page 27: Tools for Preprocessing  Mass Spectrometry Data

27

Peak DetectionNeed to detect peaks in sets of

spectraOptions:

simple – a local maxima (over a span of 3 sites) whose signal-to-[local]noise (snr) is at least 2

search (elevated intensity) – simple + higher than estimated average background [across spectra] at site

cwt – continuous wavelet transform; no denoising or detrending necessary

mrd – multiresolution decompositionmust have used MRD at denoising step

(Coombes et al. 2005; Tibshirani et al. 2004; Du et al. 2006; Randolph & Yasui 2006)

Page 28: Tools for Preprocessing  Mass Spectrometry Data

28

closed circles identify detected peaks here

intervals based on nearest local minima at least some number (41) of sites away

random seed matters here

blue line represents ‘average background’

(R code chunk 8)

Page 29: Tools for Preprocessing  Mass Spectrometry Data

29

Peak AlignmentAlign detected peaks from multiple spectra

(using only detected peaks with signal-to-noise above some threshold)

Options:cluster – 1-dim. hierarchical clustering,

with cuts between clusters based on technology precision (Coombes et al. 2005; Tibshirani et al. 2004)

gap – adjacent peaks joined if within technology precision

vote – iterative peak clustering (Yasui et al. 2003)

mrd (Randolph & Yasui 2006)smooth histogram of peak locations for

all spectratake midpoints of valleys as common

locationsm/z on log-scale at this step (roughly

constant peak width; Tibshirani et al. 2004)Precision: ±0.3% mass drift for SELDI data

Page 30: Tools for Preprocessing  Mass Spectrometry Data

30

here, spectra 2-5 (bottom to top)

circles identify detected peaks

239 common peaks aligned

intervals based on alignment algorithm(R code chunk 9)

Page 31: Tools for Preprocessing  Mass Spectrometry Data

31

Peak QuantificationPeak area is assumed to be proportional

to the corresponding detected numbers of molecules

Based on common set of peak classes, quantify each peak by one of:intensity

returns matrix of maximum peak intensities for each spectrum within each common peak

countreturns matrix of number of peaks

for each spectrum within each common peak(Dijkstra 2008)

Page 32: Tools for Preprocessing  Mass Spectrometry Data

32

Visualize Peak Quantities

(R code chunk 10)

Page 33: Tools for Preprocessing  Mass Spectrometry Data

33

(239 common peaks quantified)

24 original spectra (3 arrays, each used all 8 spots)

subsequent experiments (36 arrays, each used 2 spots)

(Coombes et al. 2003)

(R code chunk 10)

Page 34: Tools for Preprocessing  Mass Spectrometry Data

34

Peak IdentificationDetermining the exact species of protein

[or metabolite] molecule that caused a peak to be detected

Requires additional experimentation and database searches

Have to compare results with fragmentation patterns of known proteins [or metabolites]

Single protein [or metabolite] may appear as more than one peak due to complexes and/or multiple charges

(Coombes et al. 2007; Dijkstra 2008)

Page 35: Tools for Preprocessing  Mass Spectrometry Data

35

A Sidebar CaveatOriginal time (tof) values are evenly

spacedm/z values not evenly spaced

may give disproportionate weight to some m/z values at normalization (AUC)

(Coombes et al. 2007; Dijkstra 2008)

0 5000 10000 15000

050

0015

000

2500

0

time index

m/z

0 5000 10000 15000

4060

8012

016

0

time index

squa

re ro

ot m

/z

20ttV

zm

0 5000 10000 15000

050

0015

000

2500

0

time index

m/z

0 5000 10000 15000

4060

8012

016

0

time index

squa

re ro

ot m

/z

(R code chunk 11)

Page 36: Tools for Preprocessing  Mass Spectrometry Data

36

Alternative View on time vs. m/z ScaleIf replace m/z with square root (i.e.,

preprocess on “time” scale, code next slide):no difference in TIC-normalizationwould affect detrending (except for

monotone)Could affect peak detection and peak

alignmentBut, at peak alignment step, log-scale

m/z:supposed to make peak widths

roughly constantmax. intensity means something

similar to peak areaUp through Peak Detection step,

everything’s basically the same (although alternative seeds may cause slight differences)

(R code chunk 11)

Page 37: Tools for Preprocessing  Mass Spectrometry Data

37

Mean Spectrum for Detection & Alignment

“Peak detection using the mean spectrum is superior to methods that work with individual spectra and then match or bin peaks across spectra”increases sensitivity in peak detection

(especially low-intensity peaks)avoids messy and error-prone peak

alignmentspectra must first be aligned [on time

scale]small misalignments okay, just

broaden peaks in meanBut – when to take mean?

before or after detrending, denoising, and normalizing?

no definitive answer yet, but after seems reasonable

(Coombes et al. 2007; Morris et al. 2005)

Page 38: Tools for Preprocessing  Mass Spectrometry Data

38

96 peaks

239 peaks

(R code chunk 12)

Page 39: Tools for Preprocessing  Mass Spectrometry Data

39

Sample Analysis, Start to Finish

Same Example: 96 protein mass spectra generated from a pooled sample of nipple aspirate fluid (NAF) from healthy breasts and breasts with cancer

Starting point: 96 separate .txt files with two space-delimited columns (m/z, intensity) and no header row, in same directory (C:/jrstevens/DataFiles/NAFms)

msProcess can also import other formats

(R code chunk 13)

Page 40: Tools for Preprocessing  Mass Spectrometry Data

40

# Startupprint(date()); library(msProcess)

# read in .txt files to create msList objectfilepath <- "C:/jrstevens/DataFiles/NAFms"z.list <- msImport(path=filepath, pattern=".txt")# convert msList object to msSet objectz <- msPrepare(z.list, mass.min=950, data.name='example')# define type of spectrause.type <- rep("QC",96); z$type <- as.factor(use.type)# (then z is equivalent to the Breast2003QC msSet object)

# preprocessprint(date()) z1 <- msDenoise(z,FUN="wavelet")z2 <- msNoise(z1,FUN="spline")z3 <- msDetrend(z2, FUN="monotone")z4 <- msNormalize(z3, FUN="tic")set.seed(1234)z5 <- msPeak(z4, FUN="search")z6 <- msAlign(z5, FUN="cluster", snr.thresh=10, mz.precision=0.003)z7 <- msQuantify(z6, measure="intensity")print(date()) (R code chunk 13)

Page 41: Tools for Preprocessing  Mass Spectrometry Data

41

R objects of interest (pseudo-results)z$intensity = z1$intensity + z1$noisez2$local.noise = spline(|z1$noise|) (by spectra)z2$intensity = z3$intensity + z3$baselinez4$intensity = z3$intensity (transformed)z5$peak.list[[i]] = data.frame with locations and ranges of peaks for spectrum iz6$peak.class = matrix with locations and ranges of peaks for all spectraz7$peak.matrix = matrix that quantifies common peaks (col) for each spectrum (row)colnames(z7$peak.matrix) = locations (in m/z) of common peaks(see z6$peak.class for ranges of these peaks)

(R code chunk 13)

Page 42: Tools for Preprocessing  Mass Spectrometry Data

42

# visualize resultlibrary(RColorBrewer)blues.ramp <- colorRampPalette(brewer.pal(5,"Blues")[-2])pmatrix <- t(z7$peak.matrix) image(seq(numRows(pmatrix)), seq(ncol(pmatrix)), pmatrix, xaxs = "i", yaxs = "i", main = 'Peak (Intensity) Matrix', xlab = "Peak Class Index", ylab = "Spectrum Index", col=blues.ramp(200))

(R code chunk 13)

Page 43: Tools for Preprocessing  Mass Spectrometry Data

43

3400 3500 3600 3700 3800 3900 4000

3000

4000

5000

6000

7000

msPrepare for z

mass/charge

inte

nsity

3400 3500 3600 3700 3800 3900 4000

3000

4000

5000

6000

7000

msDenoise for z1

mass/charge

inte

nsity

3400 3500 3600 3700 3800 3900 4000

050

100

150

200

250

msNoise for z2

mass/charge

inte

nsity

3400 3500 3600 3700 3800 3900 4000

3000

4000

5000

6000

7000

msDetrend for z3

mass/charge

inte

nsity

3400 3500 3600 3700 3800 3900 4000

050

010

0015

00

msNormalize for z4

mass/charge

inte

nsity

3400 3500 3600 3700 3800 3900 4000

050

010

0015

00

msPeak for z5

mass/charge

inte

nsity

3400 3500 3600 3700 3800 3900 4000

050

010

0015

00

msAlign for z6

mass/charge

inte

nsity

Final object of interest: z7$peak.matrix[row=spectrum (sample), column=peak,]colnames = m/z of peak

(R code chunk 14)

Page 44: Tools for Preprocessing  Mass Spectrometry Data

44

Misc. NotesMay consider log-transforming

intensities prior to preprocessing (Morris et al. 2005)

After preprocessing, may refine list of peaks by identifying some whose m/z values are “nearly exact multiples of others and hence potentially represent the same protein” (msCharge function in msProcess package)

After preprocessing, note that peaks are not independent, a casual assumption in the usual per-gene tests for differential expression with microarray data (Coombes et al. 2007)

Denoising more important for MALDI than SELDI data (smooth over “isotopic envelope”) (Tibshirani et al. 2004)

Page 45: Tools for Preprocessing  Mass Spectrometry Data

45

Misc. NotesMALDI produces mainly singly-charged

ions (so can think of m rather than m/z of molecule) (Kaltenbach et al. 2007)

Other quality checks of spectra are available (Coombes et al. 2003: distance from first principal components, implemented in msQualify function in msProcess package)

Non-monotone baseline may be more appropriate when raw spectra are not generally monotone decreasing (Li et al. 2005)

No clear “best” preprocessing choices, but many “reasonable” ones

Page 46: Tools for Preprocessing  Mass Spectrometry Data

46

References

46

Bio-Rad (2008) Biomarker Discovery Using SELDI Technology: A Guide to Successful Study and Experimental Design. (http://www.bio-rad.com/cmc_upload/Literature/212362/Bulletin_5642.pdf)

Coombes et al. (2003) Quality Control and Peak Finding for Proteomics Data Collected From Nipple Aspirate Fluid by Surface-Enhanced Laser Desorption and Ionization. Clinical Chemistry 49(10):1615-1623.

Coombes et al. (2005) Improved Peak Detection and Quantification of Mass Spectrometry Data Acquired from Surface-Enhanced Laser Desorption and Ionization by Denoising Spectra with the Undecimated Discrete Wavelet Transform. Proteomics 5:4107-4117.

Coombes et al. (2007) Pre-Processing Mass Spectrometry Data. Ch. 4 in Fundamentals of Data Mining in Genomics and Proteomics, ed. by Dubitzky et al. Springer.

Dijkstra (2008) Bioinformatics for Mass Spectrometry: Novel Statistical Algorithms. Dissertation, U. of Groningen. (http://irs.ub.rug.nl/ppn/30666660X)

Du et al. (2006) Improved Peak Detection in Mass Spectrum by Incorporating Continuous Wavelet Transform-Based Pattern Matching. Bioinformatics 22(17):2059-2065.

Page 47: Tools for Preprocessing  Mass Spectrometry Data

47

References

47

Kaltenbach et al. (2007) SAMPI: Protein Identification with Mass Spectra Alignments. BMC Bioinformatics 8:102.

Li et al. (2005) SELDI-TOF Mass Spectrometry Protein Data. Chapter 6 in Bioinformatics and Computational Biology Solutions Using R and Bioconductor, edited by Gentleman et al.

Morris et al. (2005) Feature Extraction and Quantification for Mass Spectometry in Biomedical Applications Using the Mean Spectrum. Bioinformatics 21(9):1764-1775.

R Development Core Team (2007). R: A language and environment for statistical computing. (www.R-project.org)

Randolph & Yasui (2006) Multiscale Processing of Mass Spectrometry Data. Biometrics 62:589-597.

Tibshirani et al. (2004) Sample Classification from Protein Mass Spectrometry, by ‘Peak Probability Contrasts’. Bioinformatics 20(17):3034-3044.