Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY...
-
Upload
virginia-heath -
Category
Documents
-
view
213 -
download
0
Transcript of Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY...
![Page 1: Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY SELECTION Todd Moore University of Illinois, at Urbana-Champaign.](https://reader030.fdocuments.us/reader030/viewer/2022032705/56649dcf5503460f94ac4523/html5/thumbnails/1.jpg)
Todd Moore for the DES Collaboration PSTalk June 13th , 2007 1
DES MONSOON
LINEAR
POWER SUPPLY
SELECTION
Todd MooreUniversity of Illinois, at Urbana-Champaign
![Page 2: Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY SELECTION Todd Moore University of Illinois, at Urbana-Champaign.](https://reader030.fdocuments.us/reader030/viewer/2022032705/56649dcf5503460f94ac4523/html5/thumbnails/2.jpg)
Todd Moore for the DES Collaboration PSTalk June 13th , 2007 2
Vicor Power Supplies
• Positives– Small Packaging
• Will fit in same package as DHE
– Efficient• Efficiency is around 80%
– Built-in control circuitry• Output overcurrent protection• Independent enable/disable for each
voltage
• Negatives– Less understood– Larger output ripple than Linear (10 mV
p-p)
2 VICOR SUPPLIES
2 DHEs
![Page 3: Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY SELECTION Todd Moore University of Illinois, at Urbana-Champaign.](https://reader030.fdocuments.us/reader030/viewer/2022032705/56649dcf5503460f94ac4523/html5/thumbnails/3.jpg)
Todd Moore for the DES Collaboration PSTalk June 13th , 2007 3
Additional Testing
• Move Vsub (+48 volts) over to Vicor, so all voltages/returns come from Vicor supply
• Ramp voltage down on Vsub, then clamp outputs to a clean low impedance source– P. Moore says Vsub controls the major current path between
clocks & output stage of detector, thus any cap. coupled currents from clocks will influence the reference for the output amps
• Apply High Volts DC (100-300VDC) to input of Vicor• Understand what influence each sub-component of DHE
(i.e. CCD Acq. video channel, CBB clocks, etc.) plays in the system noise. UofI has started this.
• Any other ideas?• Otherwise use Linear supplies
![Page 4: Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY SELECTION Todd Moore University of Illinois, at Urbana-Champaign.](https://reader030.fdocuments.us/reader030/viewer/2022032705/56649dcf5503460f94ac4523/html5/thumbnails/4.jpg)
Todd Moore for the DES Collaboration PSTalk June 13th , 2007 4
Linear Power Supplies
• Positives– Very low output ripple voltage – Well understood solution
• Negatives– Large packaging
• Will not fit in same package as DHE
– Not very efficient• Efficiency is around 65%
– No Internal Monitoring/Control circuitry
• More design time
![Page 5: Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY SELECTION Todd Moore University of Illinois, at Urbana-Champaign.](https://reader030.fdocuments.us/reader030/viewer/2022032705/56649dcf5503460f94ac4523/html5/thumbnails/5.jpg)
Todd Moore for the DES Collaboration PSTalk June 13th , 2007 5
Alternative Approach
Use linear supplies mounted at the opposite end of the cage from the DES Monsoon DHE
![Page 6: Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY SELECTION Todd Moore University of Illinois, at Urbana-Champaign.](https://reader030.fdocuments.us/reader030/viewer/2022032705/56649dcf5503460f94ac4523/html5/thumbnails/6.jpg)
Todd Moore for the DES Collaboration PSTalk June 13th , 2007 6
Determining Cable Lengths
A
BC
A=31", B=58", C=31"Total Length of Cable = A+B+C= 120"/12= 10'
![Page 7: Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY SELECTION Todd Moore University of Illinois, at Urbana-Champaign.](https://reader030.fdocuments.us/reader030/viewer/2022032705/56649dcf5503460f94ac4523/html5/thumbnails/7.jpg)
Todd Moore for the DES Collaboration PSTalk June 13th , 2007 7
Power Cable Sizes and Lengths
• With 12 AWG power cable for all voltages– 10 feet long
• Heat Load from cable bundle for 6 DHEs = 50 WATTS!!• Total Diameter for 1 bundle, unshielded (x16) going to 1 DHE = .6”• Total Diameter for 6 bundles, unshielded (x96) going to 6 DHEs = 1.8”
• With 8 AWG power cable for all voltages– 10 feet long
• Heat load from cable bundle for 6 DHEs = 18 WATTS!!• Total Diameter for 1 bundle, insulated, unshielded (x16) going to 1 DHE =
1.2”• Total Diameter for 6 bundles, insulated, unshielded (x96) going to 6 DHEs =
3.6”• Mix different sizes of power cables to achieve smallest cable bundle
diameter/run & dissipated heat load/run to DHEs • Use smaller wires with short cable lengths (& less volt. drop) in the
DHE to get power to backplane and transition boards
![Page 8: Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY SELECTION Todd Moore University of Illinois, at Urbana-Champaign.](https://reader030.fdocuments.us/reader030/viewer/2022032705/56649dcf5503460f94ac4523/html5/thumbnails/8.jpg)
Todd Moore for the DES Collaboration PSTalk June 13th , 2007 8
Acopian Power Supply Selection
Nominal OutputOutput Adjust Current Standard
Volts Amps Description Voltage +/-V @ 40 Deg. C Efficiency Price Part # Case Lbs QTY
3.3V 5AGold Box, Single Output, Linear Regulated, AC-DC, Series A (High Performance) Power Supply 3.3 0.5 9A 65% $240 A3.3MT900 M9 7 6
5V 7AGold Box, Single Output, Linear Regulated, AC-DC, Series A (High Performance) Power Supply 5 0.5 12A 65% $280 A5MT1200 M13 11 6
5V 5AGold Box, Single Output, Linear Regulated, AC-DC, Series A (High Performance) Power Supply 5 0.5 12A 65% $280 A5MT1200 M13 11 12
15V 6AGold Box, Single Output, Linear Regulated, AC-DC, Series A (High Performance) Power Supply 15 0.5 8A 65% $280 A15MT800 M13 7 12
28V 1AGold Box, Single Output, Linear Regulated, AC-DC, Series A (High Performance) Power Supply 28 0.5 2.1A 65% $190 A28MT210 M6 4 6
48V 1AGold Box, Single Output, Linear Regulated, AC-DC, Series A (High Performance) Power Supply 48 1 1.2 65% $215 A48MT120 M6 4 6
TOTAL 372 48
DHEMonsoon
![Page 9: Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY SELECTION Todd Moore University of Illinois, at Urbana-Champaign.](https://reader030.fdocuments.us/reader030/viewer/2022032705/56649dcf5503460f94ac4523/html5/thumbnails/9.jpg)
Todd Moore for the DES Collaboration PSTalk June 13th , 2007 9
Size & Mounting Specs
![Page 10: Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY SELECTION Todd Moore University of Illinois, at Urbana-Champaign.](https://reader030.fdocuments.us/reader030/viewer/2022032705/56649dcf5503460f94ac4523/html5/thumbnails/10.jpg)
Todd Moore for the DES Collaboration PSTalk June 13th , 2007 10
Standard Features
• Input Voltages of 110VAC or 220VAC, 50-400Hz, Single phase
• Ripple of 250uV RMS• Regulation of +/-0.005%• Remote Sensing• Short circuit proof with automatic recovery (electronic
current limiting)• Outputs are floating
![Page 11: Todd Moore for the DES CollaborationPSTalkJune 13 th, 20071 DES MONSOON LINEAR POWER SUPPLY SELECTION Todd Moore University of Illinois, at Urbana-Champaign.](https://reader030.fdocuments.us/reader030/viewer/2022032705/56649dcf5503460f94ac4523/html5/thumbnails/11.jpg)
Todd Moore for the DES Collaboration PSTalk June 13th , 2007 11
Optional Features
• Over-voltage protection, internal SCR shorts outputs at supply with OVP condition fault
• Under/Over-voltage Alarm circuit with SPDT relay switch if power supply output deviates by:
• 1.0 volt or more: on 5 volt models
• 2.0 volts or more: on 6-48 volt models
• NO alarm for 3.3 volt models
• Power-Up/Down and fault sequencing is handled by:– Leverage engineering support at Acopian– Use solid state relays to control the AC input to each supply
• Crydon Series 1 SSR