1 Product Category IMPORTANT: Go to www.extron.com for the complete user guide and installation instructions before connecting the product to the power source. TLP Pro 320C • Setup Guide Overview The Extron TLP Pro 320C is a 3.5 inch Cable Cubby ® touchpanel with a flip-up, 320x240 LCD touchscreen with 18-bit color depth. It is ideal for any AV application requiring a compact, Cable Cubby touchpanel with a customizable interface. This guide provides instructions for experienced installers to mount and install a TLP Pro 320C touchpanel. For more complete instructions, see the TLP Pro 320C User Guide, at www.extron.com. Setup Checklist Get Ready Download and install the latest version of the following software (available from www.extron.com): Global Configurator Plus and Professional — for setting up and configuring the control processor and touchpanel. GUI Designer — for designing layouts for Extron TouchLink ® Pro touchpanels and third party touch interfaces. Obtain the following network information from your network administrator: DHCP status (on or off). If DHCP is off, you will also require the following: IP address Subnet mask Gateway User name — by default these are either admin or user. Passwords — by default these are either extron (for admin) or the field is left blank (for user). Make a note of the touchpanel MAC address. Make sure you are familiar with all the included parts and have all the necessary tools (see Tools Required for Installation on page 2) for installing the Cable Cubby. Included Parts US Power Module Universal Power Module Without Power Module AC Power Module 1 1 1 0 Pass-through AAPs 2,3 4 3 4 Blank AAPs 3 3 5 1-position bracket kit 4 0 1 0 2-position bracket kit 2 1 3 3-position bracket kit 1 1 1 NOTES: 1 Inside the US, the TLP Pro 320C can be purchased with or without an AC power module. Outside the US, see www.extron.com to find a power module that is suitable for your location. 2 Each AAP Bracket Kit consists of two brackets. The rear bracket is higher than the front bracket and has two holes for screws. 3 Active or Passive AAPs are not provided. Purchase them separately (see www.extron.com). 4 Single-space brackets can only be installed in one location (see the note and figure on page 4). TLP Pro 320C Table Clamps AC Power Module* Blank AAPs Pass-thru AAPs Extron Extron Extron Removal Tool Zip Ties #4-40 Screws and Nuts 2 Pos AAP Shelf Bracket Kits (2 brackets/kit) 3 Pos 1 Pos

Transcript of TLP Pro 320C • Setup Guide€¦ · TLP Pro 320C • Setup Guide Overview The Extron TLP Pro 320C...

1

Product Category

IMPORTANT:

Go to www.extron.com for the

complete user guide and installation

instructions before connecting the

product to the power source.TLP Pro 320C • Setup Guide

Overview

The Extron TLP Pro 320C is a 3.5 inch Cable Cubby® touchpanel with a flip-up, 320x240 LCD touchscreen with 18-bit color depth. It is ideal for any AV application requiring a compact, Cable Cubby touchpanel with a customizable interface. This guide provides instructions for experienced installers to mount and install a TLP Pro 320C touchpanel. For more complete instructions, see the TLP Pro 320C User Guide, at www.extron.com.

Setup Checklist

Get Ready � Download and install the latest version of the following software (available from www.extron.com):

Global Configurator Plus and Professional — for setting up and configuring the control processor and touchpanel.GUI Designer — for designing layouts for Extron TouchLink® Pro touchpanels and third party touch interfaces.

� Obtain the following network information from your network administrator: � DHCP status (on or off). If DHCP is off, you will also require the following:

� IP address � Subnet mask � Gateway � User name — by default these are either admin or user. � Passwords — by default these are either extron (for admin) or the field is left blank (for user).

� Make a note of the touchpanel MAC address. � Make sure you are familiar with all the included parts and have all the necessary tools (see Tools Required for Installation

on page 2) for installing the Cable Cubby.

Included Parts

US

Po

wer

  M

od

ule

Uni

vers

alP

ow

er M

od

ule

Wit

hout

Po

wer

M

od

ule

AC Power Module 1 1 1 0

Pass-through AAPs 2,3 4 3 4

Blank AAPs 3 3 5

1-position bracket kit 4 0 1 0

2-position bracket kit 2 1 3

3-position bracket kit 1 1 1

NOTES:1 Inside the US, the TLP Pro 320C can be purchased with or without an AC power module. Outside the US, see

www.extron.com to find a power module that is suitable for your location.2 Each AAP Bracket Kit consists of two brackets. The rear bracket is higher than the front bracket and has two holes for

screws.3 Active or Passive AAPs are not provided. Purchase them separately (see www.extron.com).4 Single-space brackets can only be installed in one location (see the note and figure on page 4).

TLP Pro 320C

Table Clamps

AC Power Module*

Blank AAPs Pass-thru AAPs

Extron

Extron

Extron Removal Tool

Zip Ties #4−40 Screwsand Nuts

2 Pos

AAP Shelf Bracket Kits(2 brackets/kit)

3 Pos1 Pos

2

TLP Pro 320C • Setup Guide (Continued)

Tools Required for Installation

Safety GlassesPhillips Screw Driver

Tape Measure

1/4" Hex Nut DriverMarking Pen

Square

Vacuum Cleaner

Mount and Cable All Devices

ATTENTION:• Do not power on the touchpanels or control processors until you have read the Attention in the Power Supply section

of the TLP Pro 320C User Guide or the IPL Pro User Guide.

• Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section « sources d’alimentation » du TLP Pro 320C User Guide ou du IPL Pro User Guide.

� Mount the units (see Mounting). � Install power modules in the cable cubby. � Install AAPs and run cables to the cable cubby. � Connect power and network cables to the touchpanels.

NOTE: The TLP Pro 320C can use either a 12 VDC power supply or a PoE power injector.

� Connect the power cords and power on all devices.

Set up the Touchpanels for Network Communication � Connect the PC that you will use for setup, the control processor, and the touchpanel to the same Ethernet subnetwork. � Use the Setup Menu (see Setup Menu on page 8) or the Toolbelt feature of Global Configurator Plus and Professional to set

the DHCP status and, if necessary, the IP address, subnet mask, gateway, and related settings for the touchpanel.

Configure the Touchpanels

The Global Configurator Help File, and the GUI Designer Help File provide step-by-step instructions and more detailed information. The Global Configurator Help File includes an introduction to the software and sections on how to start a project and configure it.

Mounting

Planning � Before making any cuts, select the best location for the TLP Pro 320C. � Ensure that the edge that opens on the lid is oriented correctly. � Ensure there is enough space for all the system cables and components, including cable retractors, if they are required. The

space requirements for retractors are shown in the TLP Pro 320C User Guide, which is available at www.extron.com. � Decide on the method for cutting a hole in the table:

z Hand router and template z CNC wood router z Jigsaw and paper template

� Verify that you have the correct template or dimensions. � Check all relevant regulations.

z Ensure that the installation complies with local, state, and national building and electrical codes. z Ensure that the installation complies with the Americans with Disabilities Act or other accessibility requirements.

3

Product Category

Step 1 — Obtain Cut-Out Dimensions

ATTENTION:• The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople. Exercise care

to prevent scarring or damaging the furniture.

• L’ouverture dans la table pour le Cable Cubby devrait être coupée seulement par des artisans autorisés et qualifiés. Faites attention à ne pas faire de marques sur le meuble et à ne pas l’endommager.

• Use the appropriate metal Extron routing template or refer to the surface cutout dimensions before cutting a hole in the furniture or other surface. Pay special attention to the direction the unit will face. The connector access side is underlined (see Using a CNC wood cutter). Extron is not responsible for miscut mounting holes.

• Utilisez le gabarit de détourage métallique approprié ou reportez-vous aux dimensions de découpe de la surface indiquées ci-après avant de découper le meuble ou la surface. Faites particulièrement attention à la directions dans laquelle l’unité sera dirigée. Le côté pour accéder au connecteurs est souligné (voir Using a CNC wood cutter). Extron ne sera pas responsable des erreurs de coupe.

• Ensure the table surface is at least 0.375 inch (0.95 cm) thick.

• Assurez vous que la surface de la table est au moins 0,95 cm (0,375 pouce) d’épaisseur.

If using a hand router, you should purchase the Extron TLP Pro 320C routing template.

If using a CNC wood router, use the exact cut-out dimensions (see Using a CNC wood cutter).

If using a reciprocating saw or jigsaw, use the paper cut-out template (available under the Downloads tab on the TLP Pro 320C page at www.extron.com).

Step 2 — Cut the Surface

CAUTION: Risk of personal injury: Wear safety glasses when operating power equipment.ATTENTION: Risque de blessure: Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique.

Ensure the cut is laid out in exactly the desired location and the edge that opens on the lid is correctly oriented. After verifying and checking dimensions, cut a hole in the surface of the furniture where the enclosure will be installed (see “Preparing the Table” in the TLP Pro 320C User Guide). There are three methods for cutting the hole in the table:

Using a hand router

Recommended method — Use the Extron TLP Pro 320C routing template. Refer to the Routing Template User Guide, available at www.extron.com, to prepare the template and use the template to cut the hole.

NOTE: Purchase the metal router guide separately. Do not discard it when the installation is complete as it is reusable.

Using a CNC wood cutter

Recommended method — Use the exact cut-out dimensions:

7.50 +0.00/-0.02 inches W x 6.00 +0.00/-0.02 inches D

19.05 +0.00/-0.05 cm W x 15.24 +0.00/-0.05 cm D

NOTE: The underlined dimension is the connector or AAP access side for the unit.

Using a reciprocating saw or jigsaw

Acceptable method — Use the paper cut-out template (available under the Downloads tab on the TLP Pro 320C page at www.extron.com).

HSA 200

USER ACCESS

HSA 200

CABLE CUBBY 300

CABLE CUBBY 300

USER ACCESS

Cut-Out Te

mplate for the Extron

TLP Pro 720C

Outer Edge of Tr

im Ring

(Do not cut this lin

e.)

1. Confirm the product to

be installed.

2. Remove the surface cut-out area

(gray) fr

om the template.

3. Mark the position on the wall o

r

furniture where the TLP 710MV

is being installed.

4. Cut th

e opening.

P/N 68-2046-01 Rev. B

Page size: 11" x 17"

Print scale 1:1

Do not shrink.

P/N P/

4

TLP Pro 320C • Setup Guide (Continued)

Step 3 — Run all Cables

Run all cables necessary to support the AC connector, the cables stored in the cubby, and all planned AAP connectors. Run the cables below the table and through the hole that was cut in Step 2 (see page 3). Leave enough slack in the cables to connect or route them before the cubby is installed in the table. Leave enough space under the TLP Pro 320C enclosure for the external power supply and connection of AV cables and the network connection.

Step 4 — Install Cable Retractors (Optional)

If required, Extron cable retractors should be installed in the enclosure at this stage. For complete information about retractors and how to install them, see the TLP Pro 320C User Guide and Retractors User Guide at www.extron.com.

Step 5 — Install Power Module (Optional)

ATTENTION:• For units that are used in North America, only

use AC power modules that are UL Listed Model “Cable Cubby AC Power Module”.

• Pour les unités qui sont utilisées en Amérique du Nord, utilisez seulement les modules d’alimentation secteur qui sont listés UL, modèle « Cable Cubby AC Power Module ».

• The unit is not UL Listed if it uses any AC power module other than Model “Cable Cubby AC Power Module”.

• L’unité n’est pas listée UL si elle utilise tout autre module d’alimentation secteur autre que le modèle « Cable Cubby AC Power Module ».

NOTE: For models that do not include a power module, see the Extron website to select a power module that is suitable for your location.

The power module takes up two or three AAP spaces, depending on the model. Install it before or after the AAP assembly is installed. It may be installed with AAPs on either side.

1. Secure the power module into position with #4-40 Phillips head screws and star washers.

CAUTION: Risk of electric shock: To ensure proper electrical grounding, use the provided grounding screws and star washers.

ATTENTION : Risque de choc électrique: Afin d’assurer une mise à la terre correcte, utilisez les fixations de mise à la terre et les rondelles en étoile fournies.

2. Run the cable or conduit to a convenient junction box. Extron recommends the circuit be attached to a junction box that is directly wired to the main circuit.

Step 6 — AAP Assembly

Install all desired cables into the cable pass-through AAPs and install the AAPs into the cable cubby.

The simplest way to install the cables and AAPs is to populate the AAP brackets outside the cubby and then install the populated AAP shelf assembly into the cubby.

Install cables in the pass-through holes as shown in the figure to the right.

TIP: Hand tightening the #4-40 nuts makes it easier to place and secure the assembly inside the enclosure.

NOTE: An extra column of AAP bracket mounting points is available for use with TLP Single-space AAP mounting brackets. Single-space brackets will not fit in any other location.

Rear Brackets

Front Brackets

Secure the power moduleto the TLP Pro 320C framewith #4-40 Phillips headscrews and star washers.

The extra columnof mounting pointsis for installingsingle-spaceAAP brackets.

5

Product Category

Step 7 — Install the AAP Assembly

1. From under the table, push the first AAP assembly through the bottom of the enclosure. The holes in the rear bracket must align with the bottom row of holes on the rear face of the enclosure.

TIP: Ensure there is enough space above the AAP assembly for the lid to close completely without cables or connectors contacting the touchpanel.

2. Secure the AAP assembly into position with the provided Phillips head screws.

3. Tighten the nuts that secure the AAPs to the brackets.

Step 8 — Mount the Enclosure

Mount the cable cubby enclosure in the table.

CAUTION: The flanged edges of the top of the surface enclosure are sharp. These edges are also soft and may be easily nicked or bent. Exercise caution when handling the enclosure to prevent personal injury or damage to the enclosure.

ATTENTION : Les extrémités à brides du haut de la surface du boîtier sont aiguisées. Ces extrémités sont aussi lisses et peuvent facilement être coupées ou pliées. Soyez prudents lorsque vous manipulez le boîtier afin d’éviter de l’endommager ou de vous blesser.

1. Remove the edge grommet protecting the edges of the trim ring and the plastic film on the finished surfaces.

ATTENTION:• Do not use isopropyl alcohol or other solvents to

clean the Cable Cubby. Strong solvents will ruin some finishes.

• Ne pas utiliser de l’alcool isoproprylique ou d’autres solvants pour nettoyer le Cable Cubby. Les solvants forts endommageront certaines finitions.

2. Carefully lower the enclosure into the hole cut in the table (see Step 2 — Cut the Surface on page 3). Ensure the trim ring (5) is flush with the top of the table.

3. Under the table, attach the table clamps (3) to the pins on each side of the enclosure. It may be necessary to loosen the wingnuts (1) and the Phillips head screws (2).

4. When the clamps are properly seated on the pins, tighten the Phillips head screws until the clamp faces (4) are tightly secured against the bottom of the table.

5. To prevent the screws from becoming loose, secure the wingnuts against the table clamp bodies.

11

55

22

33

44

COMPUTER

AUDIO

Phillips Head Screws(secure AAP assembly)

Tighten downAAP nuts.

Push assembly through bottom of enclosure.

Large holes provide tool access to fastenrear brackets.

11

22

33

6

TLP Pro 320C • Setup Guide (Continued)

Connecting the TLP Pro 320C

The cable connections are located in a panel on the bottom of the TLP Pro 320C:

AA

BB

A Power connector — Connect a 12 VDC, 1.0 A power supply (not provided) to this 2-pole, 3.5 mm captive screw connector.

ATTENTION:• The TLP Pro 320C can use a 12 VDC desktop power supply and is also Power over Ethernet (PoE 802.3af,

class 3) compliant. Do not connect either power supply before reading the Attention in the Power Supply sections of the TLP Pro 320C User Guide.

• Le TLP Pro 320C peut utiliser une source d’alimentation externe 12 Vcc, et est également compatible avec l’alimentation POE via Ethernet (PoE 802.3af, classe 3). Ne branchez pas de sources d’alimentation externes avant d’avoir lu les mises en garde dans la section « Power Supply » du TLP Pro 320C User Guide.

NOTE: The TLP Pro 320C ships without a power supply. Either the 12 VDC power supply or the power injector must be purchased separately.

B Network and Power over Ethernet (PoE) Connector — Connect the touchpanel to the LAN using a twisted pair cable, terminated with an RJ-45 connector. The connector can also be used with a PoE power injector (not provided).An Extron IP Link Pro control processor must also be connected to the same network as the TouchLink Pro touchpanel.

7

Product Category

Front Panel Features

To see all the front panel features, remove the bezel, using the Extron Removal Tool (see Included Parts on page 1). For a complete description of all these features and their function, see the TLP Pro 320C User Guide.

ATTENTION:• When you slide the removal tool between the screen and the bezel, take care to avoid damaging the ribbon

cable, which runs close to the edge of the bezel.• Lorsque vous faites glisser l’outil d’extraction entre l’écran et le châssis, faites attention à éviter d’endommager

la nappe de raccordement se trouvant à proximité du bord du châssis.

DD

AA BB

CC

EE FF GG

A Ambient light sensor — This sensor monitors ambient light level and adjusts screen brightness, based on the settings configured using the setup menu (see page 8).

B Communication LED — This LED shows the configuration and connection status of the touchpanel: z Unlit during normal operation (the touchpanel is configured and connected to an IP Link Pro control processor). z Blinks red if the touchpanel has been configured but is not connected to an IP Link Pro control processor. z Permanently lit if the touchpanel has not been configured.

The indicator can be toggled between enabled and disabled, using the setup menu.

C LCD screen — The TLP Pro 320C has a 3.5 inch screen with a 320x240 resolution.

D Configurable buttons — 10 dedicated, customizable, function buttons provide quick access to key functions. The buttons that are supplied with the TLP Pro 320C can be replaced to meet your needs. For information about replacing buttons, see the TLP Pro 320C User Guide.

E Reset LED— This LED indicates power status and reset status of the device.

F Reset button — This button allows the unit to be reset. The TLP Pro 320C has three reset modes that are initiated by pressing the reset button (see Reset Modes: a Brief Summary on page 8). For full information about these different modes, see the TLP Pro 320C User Guide.

G Menu button — This button activates the setup menu and calibration screen (see page 8).

H Bezel — To detach the bezel, use the included removal tool (see the figure to the right, above).

I Bezel removal slots — The slots allow removal of bezel, using Extron removal tool.

J Illumination LED — This LED provides light for cable cubby enclosure.

K Speaker — A single speaker, located inside the cable cubby, provides audible feedback for the user.

HH

II

JJKK

DD

8

68-2516-50 Rev. A05 15

Extron Headquarters+1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East+1.714.491.1500 +1.919.850.1000+1.714.491.1517 FAX +1.919.850.1001 FAX

Extron Europe+800.3987.6673 (Inside Europe Only)+31.33.453.4040+31.33.453.4050 FAX

Extron Asia+65.6383.4400+65.6383.4664 FAX

Extron Japan+81.3.3511.7655+81.3.3511.7656 FAX

Extron China+86.21.3760.1568+86.21.3760.1566 FAX

Extron Middle East+971.4.299.1800+971.4.299.1880 FAX

Extron Korea+82.2.3444.1571+82.2.3444.1575 FAX

Extron India1800.3070.3777 (Inside India Only)+91.80.3055.3777+91.80.3055.3737 FAX

© 2015 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com

TLP Pro 320C • Setup Guide (Continued)

Reset Modes: a Brief Summary

The TLP Pro 320C offers the following reset modes (see the TLP Pro 320C User Guide for complete information):

• Use factory firmware: Press and hold the Reset button (see Front Panel Features, F, on page 7) while applying power to the unit. Use this mode to replace firmware in the event of firmware failure.

• Reset All IP Settings: Press and hold the Reset until the Reset LED (see Front Panel Features, E) blinks twice (approximately 6 seconds). Release and momentarily press the Reset button. Use this mode to reset all network settings without affecting user-loaded files.

• Reset to Factory Defaults: Press and hold the Reset button until the Reset LED blinks three times (approximately 9 seconds). Release and momentarily press the Reset button. Use this mode to return the interface to factory default settings.

Setup Menu

The setup menu opens when the menu button is pressed (see Front Panel Features, G). The image to the right shows the entire Status screen. Because of size of the touchscreen, you can only see part of the Status screen at any time. Use your finger to scroll up or down within the screen.

There are five different screens: Status, (shown in the figure to the right) Network, Display, Audio, and Advanced. The screens can be selected by pressing the Menu button at the top left of the screen or by pressing the light gray bar with the name of the destination screen. An arrow to the right of the bar indicates that the bar links to another screen (for more information about each screen, see the TLP Pro 320C User Guide).

Press the Menu button for at least 3 seconds to open the calibration screen. Follow the on-screen instructions.

Status Exit

INFO

Model:

Part Number:

Firmware Version:

PoE:

TLP Pro 320C

60-1452-02

1.03.0000.b001

Active

NETWORK

DHCP:

Hostname:

IP Address:

TLP-Pro-320C-AB-CD-EF

192.168.254.251

DISPLAY

Screen Resolution: 320x240

Sleep Timer: 5 Minutes

AUDIO

Master Volume: 80

Master Mute: Off

ADVANCED

Controller IP: 192.168.254.250

Storage Usage: 1/151 MB

Bootloader Version: 1.03.0000

Off