TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed...

44

Transcript of TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed...

Page 1: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting
Page 2: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Contents

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 2

About TKF 3Symbols 4

Product informationMarket search

Offshore 5

Terms and Conditions 42Reel size and Weight 43

Page 3: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

© BV Twentsche Kabelfabriek Subject to technical alterations www.tkf.nl-

About TKF

Founded in 1930, TKF has developed from a local Dutch cable producer to a cable

technology leader servicing customers all over the world. As a member of TKH

Group NV, a Dutch-based international group of technology-powered companies,

TKF has access to various international marketing, purchasing,

sales and research groups with diverse specialisms.

TKF has dedicated itself to delivering innovative Telecom, Building and Industrial

Solutions that match specific customer needs. A good strategy, looking at the

long-term relationships between TKF and a growing number of companies.

Professionals who value the continuous pursuit of a better understanding

between suppliers, customers, contractors, installers and end-users.

TKF naturally takes its corporate social responsibility into account.

Innovation, Growth and Responsibility are key factors for TKF.

Choose TKF - Choose quality!

Interested in more information about TKF and our

wide range of products and services? Please visit

our website www.tkf.nl for more information.

Page 4: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

o MV Tm[djiY^[ QWX[b\WXh_[a SkX`[Yj je j[Y^d_YWb Wbj[hWj_edi mmmFja\FdbE

M^TU]b _`^bUSbUT

T^[ YWXb[ _i Z[i_]d[Z je ]_l[ iec[ fhej[Yj_ed

W]W_dij heZ[djiF

MQTYQ[ dQbU` R[^SZY]W

T^[ ekj[h i^[Wj^ e\ j^[ YWXb[ _i Z[i_]d[Z

je fh[l[dj mWj[h [dj[h_d] _dje j^[ YWXb[F

T^[ YWXb[ _i fhel_Z[Z m_j^ W ce_ijkh[

XWhh_[h j^Wj fh[l[dji hWZ_Wb _d]h[ii e\ mWj[hF

GY`U `UaYabQ]b

T^[ YWXb[ ^Wi Wd _cfhel[Z ef[hWj_edWb

9/43+,343<? 36 @9/ ;3<=+<376;#

G[Q\U `UbQ`TU]b

T^[ ekj[h i^[Wj^ e\ j^[ YWXb[ _i cWZ[ e\ W

A+5/"9/<+9./6< +6. ;/40"/><361=3;2361 5+</93+4#

D^\_QSb TUaYW]

ScWbb[h YWXb[ Z_Wc[j[h Zk[ je j^[ Wffb_YWj_ed

e\ i[YjehEi^Wf[Z YedZkYjehiF

G[UeYR[U SQR[Ua

NWXb[i m_j^ h[ZkY[Z X[dZ_d] ij_\\d[iiF

DXU\YSQ[ `UaYabQ]SU

NWXb[i m_j^ _cfhel[Z h[i_ijWdY[ W]W_dij

W]]h[ii_l[ Y^[c_YWbiF

KUTYc\ Q]T HYWX P^[bQWU SQR[Ua

NWXb[i Z[i_]d[Z \eh j^[ jhWdfehjWj_ed

e\ j[di_edi e\ KGIH aV kf je JLGKK aVF

EQbQ SQR[Ua

Sk_jWXb[ \eh j^[ jhWdic_ii_ed e\ efj_YWb eh

[b[Yjh_Y ^_]^ \h[gk[dYn i_]dWbF

D^__U` bU[US^\\c]YSQbY^] SQR[Ua

NWXb[i m_j^ incc[jh_YWbbn ijhWdZ[Z [b[c[dji

\eh j^[ jhWdic_ii_ed e\ j[b[Yecckd_YWj_ed

i_]dWbiF Udi^_[bZ[ZD i^_[bZ[Z eh ckbj_fb[ i^_[bZ[ZF

M^TU]b `UaYabQ]b

T^[ YWXb[ _i heZ[dj fhee\ Xn c[Wdi

e\ W c[jWb XWhh_[hF

J^]WYbcTY]Q[ dQbU` R[^SZY]W

Ok[ je j^[ YWXb[ YedijhkYj_ed WdZ j^[

cWj[h_Wbi ki[ZD mWj[h _di_Z[ j^[ Yeh[ YWddej

ifh[WZ j^hek]^ j^[ YWXb[ bed]_jkZ_dWbbnF

J^d a\^ZUBXQ[^WU] V`UU

*/.=-/. /53;;376; 70 0=5/ +6. <7>3- 1+;

36 -+;/ 70 @9/#

D^__U` R`QYT

NWXb[i m_j^ Bj_dd[ZC Yeff[h XhW_Z \eh _cfhel[Z

;23/4.361 +1+36;< /4/-<975+16/<3- 36A=/6-/;

WdZ c[Y^Wd_YWb fhej[Yj_edF

FKDCFKI

&>-/44/6< &)%$&)( 8978/9<3/;#

OU\_U`Qbc`U `Q]WU

Sk_jWXb[ \eh m_Z[ j[cf[hWjkh[ hWd][F

KQ`Y]U Q]T LVVaX^`U SQR[Ua

'+471/6 09// +6. A+5/ 9/<+9.+6< -+,4/; 079

Wffb_YWj_ed ed XeWhZ i^_fi WdZ e\\i^eh[

fbWj\ehciF

NYW]Q[ SQR[Ua

NWXb[i m_j^ dkcX[h[Z Yeh[i Z[i_]d[Z \eh

j^[ jhWdifehj e\ i_]dWbi X[jm[[d fheY[ii[i

WdZ YedjhebF

F]WY]U SQR[Ua

T^h[[ Yeh[ YWXb[i \eh j^[ [b[Yjh_Y ikffbn e\

[d]_d[iF

I]ab`c\U]bQbY^] SQR[Ua

NWXb[i \eh _dijhkc[djWj_ed WdZ Yedjheb

inij[ci \eh lWh_eki WdWbe]k[ WdZGeh Z_]_jWb

i_]dWb jhWdic_ii_edF

LVVaX^`U SQR[Ua

'+471/6 09// +6. A+5/ 9/<+9.+6< -+,4/;

\eh Wffb_YWj_ed ed XeWhZ e\\i^eh[ fbWj\ehciF

SncXebi

&&%&%&

&%&&&

%&%%&%

&&%&%&

&%&&&

%&%%&%

'"!

Page 5: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Contents

Offshore

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 5

Low voltage power cablesO-Line+ RFOU P1/P8 7

O-Line+ BFOU P5/P12 11

O-Line+ UX P15 15

Communication cablesO-Line+ RFOU (i) S1/S5 17

O-Line+ RFOU (c) S2/S6 21

O-Line+ BFOU (i) S3/S7 25

O-Line+ BFOU (c) S4/S8 29

Appendix 33

Page 6: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

High-end solutions for all offshore cable applications

Offshore Cables

O-Line+ BFOU (c) S4/S8Communication cable

O-Line+ BFOU (i) S3/S7Communication cable

O-Line+ RFOU (c) S2/S6Communication cable

O-Line+ RFOU (i) S1/S5Communication cable

O-Line+ UX P15Low voltage power cable

O-Line+ BFOU P5/P12Low voltage power cable

OLine+ RFOU P1/P8Low voltage power cable

O-Line+ BFOU (c) S4/S8Communication cable

© BV Twentsche Kabelfabriek Subject to technical alternations www.tkf.nl

Page 7: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU P1/P8 0,6/1 kV

Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe &

EX-areas. For power, control and lighting applications. Design standards: IEC-60092-353 and NEK TS

606-2009. With tinned copper wire braid for EMI and mechanical protection, with sufficient cross section

to be used as Protective Earth according to IEC 60092-352. Cores sizes >25mm2 have extra flexible

Class 5/6 conductors with resistance Class 2, for improved flexibility. Different sheath colours on

request.

Characteristics Properties Unit

Product group Shipboard low voltage cable

Series Offshore cable

Type O-Line+ RFOU P1/P8 0,6/1 kV

Standardization NEK TS 606

Conductor material Cu, tinned

Shape of conductor Round

Core insulation Rubber (HEPR)

Conductor category Article dependant, see detail sheet

Core identification HD 308 S2

Construction outer shield Tinned copper braiding

Material outer sheath SHF2 MUD

Colour outer sheath Article dependant, see detail sheet

Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A

Halogen free IEC 60754-1/2

Nominal voltage U0 0.6 kV

Nominal voltage U 1 kV

Maximum conductor temperature 90 °C

Operating temperature, flexible -20 / 70 °C

Operating temperature, fixed -40 / 70 °C

Specification See appendix

Partnumber Construction

Nominalearthscreendiameter(mm²)

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35001 2 x 1 mm² 4 207 69 11,5 30

35002 3 x 1 mm² 4 225 71 11,9 45

35003 4 x 1 mm² 4 251 76 12,6 60

35004 5 x 1 mm² 6 319 83 13,8 75

35026 3 G 1,5 mm² - 255 75 12,5 68

35027 4 G 1,5 mm² - 321 82 13,6 90

35028 5 G 1,5 mm² - 364 88 14,7 113

35029 7 G 1,5 mm² - 412 94 15,7 158

35010 1 x 1,5 mm² 2,5 117 53 8,9 23

35011 2 x 1,5 mm² 4 258 72 12 45

35012 3 x 1,5 mm² 4 255 75 12,5 68

35013 4 x 1,5 mm² 6 321 82 13,6 90

35014 5 x 1,5 mm² 6 364 88 14,7 113

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 7

Page 8: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU P1/P8 0,6/1 kV

Partnumber Construction

Nominalearthscreendiameter(mm²)

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35015 6 x 1,5 mm² 10 415 94 15,7 135

35016 7 x 1,5 mm² 10 412 94 15,7 158

35017 8 x 1,5 mm² 10 483 102 17 180

35018 10 x 1,5 mm² 10 567 113 18,8 225

35019 12 x 1,5 mm² 10 602 116 19,4 270

35020 16 x 1,5 mm² 10 725 128 21,3 360

35021 19 x 1,5 mm² 10 804 134 22,4 428

35022 24 x 1,5 mm² 10 988 149 24,9 540

35023 27 x 1,5 mm² 10 1049 155 25,9 608

35024 30 x 1,5 mm² 10 1124 161 26,9 675

35025 37 x 1,5 mm² 10 1318 175 29,2 833

35046 3 G 2,5 mm² - 338 83 13,8 113

35196 3 G 2,5 mm² - 336 82 13,7 113

35047 4 G 2,5 mm² - 384 89 14,9 150

35048 5 G 2,5 mm² - 440 95 15,9 188

35197 5 G 2,5 mm² - 435 94 15,7 188

35049 7 G 2,5 mm² - 511 103 17,2 263

35030 1 x 2,5 mm² 4 134 56 9,4 38

35031 2 x 2,5 mm² 4 273 77 12,9 75

35032 3 x 2,5 mm² 6 338 83 13,8 113

35033 4 x 2,5 mm² 6 384 89 14,9 150

35034 5 x 2,5 mm² 10 440 95 15,9 188

35035 6 x 2,5 mm² 10 511 103 17,2 225

35036 7 x 2,5 mm² 10 511 103 17,2 263

35037 8 x 2,5 mm² 10 597 112 18,6 300

35038 10 x 2,5 mm² 10 723 125 20,8 375

35039 12 x 2,5 mm² 10 752 128 21,3 450

35040 16 x 2,5 mm² 10 928 142 23,7 600

35041 19 x 2,5 mm² 10 1024 148 24,7 713

35042 24 x 2,5 mm² 10 1280 166 27,7 900

35043 27 x 2,5 mm² 10 1364 173 28,9 1013

35044 30 x 2,5 mm² 10 1466 180 30 1125

35045 37 x 2,5 mm² 16 1733 196 32,7 1388

35055 3 G 4 mm² - 427 91 15,2 180

35056 4 G 4 mm² - 491 97 16,2 240

35057 5 G 4 mm² - 568 106 17,6 300

35050 1 x 4 mm² 4 155 59 9,9 60

35051 2 x 4 mm² 6 377 88 14,6 120

35052 3 x 4 mm² 10 427 91 15,2 180

35053 4 x 4 mm² 10 491 97 16,2 240

35054 5 x 4 mm² 10 568 106 17,6 300

35065 3 G 6 mm² - 521 98 16,4 270

35066 4 G 6 mm² - 617 107 17,8 360

35067 5 G 6 mm² - 706 115 19,1 450

35060 1 x 6 mm² 4 184 63 10,5 90

35061 2 x 6 mm² 10 458 95 15,8 180

35062 3 x 6 mm² 10 521 98 16,4 270

35063 4 x 6 mm² 10 617 107 17,8 360

35064 5 x 6 mm² 10 709 115 19,1 450

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 8

Page 9: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU P1/P8 0,6/1 kV

Partnumber Construction

Nominalearthscreendiameter(mm²)

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35075 3 G 10 mm² - 716 114 19 720

35076 4 G 10 mm² - 853 124 20,6 960

35077 5 G 10 mm² - 978 133 22,2 1200

35070 1 x 10 mm² 4 243 71 11,8 240

35071 2 x 10 mm² 10 615 109 18,1 480

35072 3 x 10 mm² 10 716 114 19 720

35073 4 x 10 mm² 10 853 124 20,6 960

35074 5 x 10 mm² 10 978 133 22,2 1200

35085 3 G 16 mm² - 972 125 20,9 720

35086 4 G 16 mm² - 1176 136 22,7 960

35087 5 G 16 mm² - 1404 148 24,6 1200

35080 1 x 16 mm² 4 317 76 12,6 240

35081 2 x 16 mm² 16 859 119 19,9 480

35082 3 x 16 mm² 16 1010 125 20,9 720

35083 4 x 16 mm² 16 1202 136 22,7 960

35084 5 x 16 mm² 16 1429 148 24,6 1200

35095 3 G 25 mm² - 1384 146 24,3 1125

35096 4 G 25 mm² - 1689 159 26,5 1500

35097 5 G 25 mm² - 2045 174 29 1875

35090 1 x 25 mm² 10 478 88 14,7 375

35091 2 x 25 mm² 16 1165 139 23,1 750

35092 3 x 25 mm² 16 1397 146 24,3 1125

35093 4 x 25 mm² 16 1689 159 26,5 1500

35094 5 x 25 mm² 16 2045 174 29 1875

35105 3 G 35 mm² - 1777 169 28,2 1575

35107 5 G 35 mm² - 2628 203 33,8 2625

35100 1 x 35 mm² 10 582 98 16,4 525

35101 2 x 35 mm² 16 1478 160 26,7 1050

35102 3 x 35 mm² 16 1777 169 28,2 1575

35103 4 x 35 mm² 16 2168 185 30,8 2100

35104 5 x 35 mm² 16 2628 203 33,8 2625

35115 3 G 50 mm² - 2267 190 31,6 2250

35117 5 G 50 mm² - 3533 235 39,2 3750

35110 1 x 50 mm² 10 724 106 17,7 750

35111 2 x 50 mm² 25 1987 181 30,1 1500

35112 3 x 50 mm² 25 2370 192 32 2250

35113 4 x 50 mm² 25 2854 210 35 3000

35114 5 x 50 mm² 25 3532 235 39,2 3750

35125 3 G 70 mm² - 3256 224 37,4 3150

35120 1 x 70 mm² 10 964 121 20,2 1050

35121 2 x 70 mm² 35 2672 207 34,5 2100

35122 3 x 70 mm² 35 3315 224 37,4 3150

35123 4 x 70 mm² 35 4022 246 41 4200

35124 5 x 70 mm² 35 4834 271 45,2 5250

35135 3 G 95 mm² - 4306 253 42,1 4275

35130 1 x 95 mm² 10 1248 130 21,7 1425

35131 2 x 95 mm² 50 3625 240 40 2850

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 9

Page 10: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU P1/P8 0,6/1 kV

Partnumber Construction

Nominalearthscreendiameter(mm²)

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35132 3 x 95 mm² 50 4479 255 42,5 4275

35133 4 x 95 mm² 50 5484 281 46,8 5700

35134 5 x 95 mm² 50 6562 308 51,4 7125

35145 3 G 120 mm² - 5188 276 46 5400

35140 1 x 120 mm² 10 1497 141 23,5 1800

35141 2 x 120 mm² 60 4470 262 43,7 3600

35142 3 x 120 mm² 60 5416 278 46,4 5400

35143 4 x 120 mm² 60 6654 306 51 7200

35144 5 x 120 mm² 60 7997 338 56,3 9000

35150 1 x 150 mm² 10 1800 154 25,6 2250

35151 2 x 150 mm² 70 5321 286 47,7 4500

35152 3 x 150 mm² 70 6521 304 50,7 6750

35153 4 x 150 mm² 70 8013 336 56 9000

35154 5 x 150 mm² 70 9619 371 61,8 11250

35160 1 x 185 mm² 16 2228 169 28,1 2775

35161 2 x 185 mm² 95 6888 331 55,2 5550

35162 3 x 185 mm² 95 8427 352 58,6 8325

35163 4 x 185 mm² 95 10362 387 64,5 11100

35164 5 x 185 mm² 95 12466 427 71,1 13875

35170 1 x 240 mm² 16 2773 184 30,7 3600

35171 2 x 240 mm² 120 8647 365 60,9 7200

35172 3 x 240 mm² 120 10596 388 64,6 10800

35173 4 x 240 mm² 120 13069 428 71,4 14400

35174 5 x 240 mm² 120 15739 472 78,7 18000

35180 1 x 300 mm² 16 3386 208 34,6 4500

35181 2 x 300 mm² 150 10601 409 68,2 9000

35182 3 x 300 mm² 150 13070 434 72,4 13500

35183 4 x 300 mm² 150 16169 479 79,8 18000

35184 5 x 300 mm² 150 19565 527 87,9 22500

35185 1 x 400 mm² 25 4466 235 39,1 6000

35190 1 x 630 mm² 35 6929 284 47,4 9450

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 10

Page 11: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU P5/P12 0,6/1 kV

Fire Resistant, Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore

topsides in safe & EX-areas.. For power, control and lighting applications. Design standards:

IEC-60092-353 and NEK TS 606-2009. With tinned copper wire braid for EMI and mechanical

protection, with sufficient cross section to be used as Protective Earth according to IEC 60092-352.

Meets the fire resistant standards set both by the IEC 60331-21 and the more demanding 60331- 1/ 2

(2009) specification for use in areas where circuit integrity in fire conditions is required. Cores sizes

>25mm2 have extra flexible Class 5/6 conductors with resistance Class 2, for improved flexibility.

Different sheath colours on request.

Characteristics Properties Unit

Product group Shipboard low voltage cable

Series Offshore cable

Type O-Line+ BFOU P5/P12 0,6/1 kV

Standardization NEK TS 606

Conductor material Cu, tinned

Shape of conductor Round

Core insulation Mica + HEPR

Conductor category Class 2 = stranded

Core identification HD 308 S2

Construction outer shield Tinned copper braiding

Material outer sheath SHF2 MUD

Colour outer sheath Black

Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A

Halogen free IEC 60754-1/2

Insulation integrity in accordance with IEC 60331 Yes

Nominal voltage U0 0.6 kV

Nominal voltage U 1 kV

Maximum conductor temperature 90 °C

Operating temperature, flexible -20 / 70 °C

Operating temperature, fixed -40 / 70 °C

Specification See appendix

Partnumber Construction

Nominalearthscreendiameter(mm²)

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35201 2 x 1 mm² 6 304 82 13,6 30

35202 3 x 1 mm² 6 322 85 14,1 45

35203 4 x 1 mm² 10 366 91 15,2 60

35204 5 x 1 mm² 10 414 97 16,2 75

35226 3 G 1,5 mm² - 350 88 14,7 68

35227 4 G 1,5 mm² - 404 95 15,9 90

35228 5 G 1,5 mm² - 459 102 17 113

35229 7 G 1,5 mm² - 521 110 18,4 158

35210 1 x 1,5 mm² 4 135 59 9,8 23

35211 2 x 1,5 mm² 6 326 85 14,1 45

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 11

Page 12: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU P5/P12 0,6/1 kV

Partnumber Construction

Nominalearthscreendiameter(mm²)

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35212 3 x 1,5 mm² 6 350 88 14,7 68

35213 4 x 1,5 mm² 10 403 95 15,9 90

35214 5 x 1,5 mm² 10 459 102 17 113

35215 6 x 1,5 mm² 10 531 110 18,4 135

35216 7 x 1,5 mm² 10 521 110 18,4 158

35217 8 x 1,5 mm² 10 611 119 19,9 180

35218 10 x 1,5 mm² 10 728 134 22,3 225

35219 12 x 1,5 mm² 10 761 137 22,9 270

35220 16 x 1,5 mm² 10 933 153 25,5 360

35221 19 x 1,5 mm² 10 1019 160 26,6 428

35222 24 x 1,5 mm² 10 1266 180 30 540

35223 27 x 1,5 mm² 16 1349 188 31,3 608

35224 30 x 1,5 mm² 16 1448 196 32,6 675

35225 37 x 1,5 mm² 25 1877 220 36,7 833

35246 3 G 2,5 mm² - 418 95 15,9 113

35247 4 G 2,5 mm² - 470 101 16,9 150

35248 5 G 2,5 mm² - 551 110 18,4 188

35249 7 G 2,5 mm² - 620 118 19,7 263

35230 1 x 2,5 mm² 4 152 61 10,2 38

35231 2 x 2,5 mm² 10 383 91 15,2 75

35232 3 x 2,5 mm² 10 417 95 15,9 113

35233 4 x 2,5 mm² 10 470 101 16,9 150

35234 5 x 2,5 mm² 10 551 110 18,4 188

35235 6 x 2,5 mm² 10 626 118 19,7 225

35236 7 x 2,5 mm² 10 620 118 19,7 263

35237 8 x 2,5 mm² 10 746 130 21,6 300

35238 10 x 2,5 mm² 10 889 146 24,3 375

35239 12 x 2,5 mm² 10 937 150 25 450

35240 16 x 2,5 mm² 16 1157 167 27,9 600

35241 19 x 2,5 mm² 10 1273 175 29,1 713

35242 24 x 2,5 mm² 16 1589 197 32,8 900

35243 27 x 2,5 mm² 16 1700 206 34,4 1013

35244 30 x 2,5 mm² 25 2006 222 37 1125

35245 37 x 2,5 mm² 25 2368 241 40,2 1388

35255 3 G 4 mm² - 501 102 17 180

35256 4 G 4 mm² - 584 110 18,4 240

35257 5 G 4 mm² - 674 119 19,8 300

35250 1 x 4 mm² 4 179 65 10,8 60

35251 2 x 4 mm² 10 456 98 16,3 120

35252 3 x 4 mm² 10 511 102 17 180

35253 4 x 4 mm² 10 583 110 18,4 240

35254 5 x 4 mm² 10 674 119 19,8 300

35265 3 G 6 mm² - 610 110 18,4 270

35266 4 G 6 mm² - 710 119 19,8 360

35267 5 G 6 mm² - 844 130 21,6 450

35260 1 x 6 mm² 4 210 69 11,5 90

35261 2 x 6 mm² 10 530 104 17,4 180

35262 3 x 6 mm² 10 610 110 18,4 270

35263 4 x 6 mm² 10 710 119 19,8 360

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 12

Page 13: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU P5/P12 0,6/1 kV

Partnumber Construction

Nominalearthscreendiameter(mm²)

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35264 5 x 6 mm² 10 843 130 21,6 450

35275 3 G 10 mm² - 823 126 21 450

35276 4 G 10 mm² - 965 136 22,6 600

35277 5 G 10 mm² - 1138 148 24,7 750

35270 1 x 10 mm² 4 266 76 12,6 150

35271 2 x 10 mm² 10 703 119 19,8 300

35272 3 x 10 mm² 10 823 126 21 450

35273 4 x 10 mm² 10 965 136 22,6 600

35274 5 x 10 mm² 10 1138 148 24,7 750

35285 3 G 16 mm² - 1085 137 22,8 720

35286 4 G 16 mm² - 1304 149 24,8 960

35287 5 G 16 mm² - 1568 163 27,1 1200

35280 1 x 16 mm² 6 378 83 13,8 240

35281 2 x 16 mm² 16 953 130 21,7 480

35282 3 x 16 mm² 16 1080 137 22,8 720

35283 4 x 16 mm² 16 1330 149 24,8 960

35284 5 x 16 mm² 16 1568 163 27,1 1200

35295 3 G 25 mm² - 1542 160 26,7 1125

35296 4 G 25 mm² - 1862 174 29 1500

35297 5 G 25 mm² - 2254 191 31,8 1875

35290 1 x 25 mm² 10 515 94 15,7 375

35291 2 x 25 mm² 16 1304 151 25,2 750

35292 3 x 25 mm² 16 1541 160 26,7 1125

35293 4 x 25 mm² 16 1861 174 29 1500

35294 5 x 25 mm² 16 2254 191 31,8 1875

35305 3 G 35 mm² - 1952 183 30,5 1575

35307 5 G 35 mm² - 3068 228 38 2625

35300 1 x 35 mm² 10 615 104 17,4 525

35301 2 x 35 mm² 16 1638 173 28,8 1050

35302 3 x 35 mm² 16 1952 183 30,5 1575

35303 4 x 35 mm² 16 2385 201 33,5 2100

35304 5 x 35 mm² 25 3067 228 38 2625

35315 3 G 50 mm² - 2440 203 33,8 2250

35317 5 G 50 mm² - 3754 251 41,9 3750

35310 1 x 50 mm² 10 765 112 18,7 750

35311 2 x 50 mm² 25 2119 193 32,2 1500

35312 3 x 50 mm² 25 2518 205 34,2 2250

35313 4 x 50 mm² 25 3172 230 38,3 3000

35314 5 x 50 mm² 25 3754 251 41,9 3750

35325 3 G 70 mm² - 3472 238 39,6 3150

35320 1 x 70 mm² 10 1015 128 21,3 1050

35321 2 x 70 mm² 35 2927 225 37,5 2100

35322 3 x 70 mm² 35 3498 238 39,6 3150

35323 4 x 70 mm² 35 4267 262 43,7 4200

35324 5 x 70 mm² 35 5082 287 47,9 5250

35335 3 G 95 mm² - 4568 266 44,3 4275

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 13

Page 14: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU P5/P12 0,6/1 kV

Partnumber Construction

Nominalearthscreendiameter(mm²)

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35330 1 x 95 mm² 10 1307 136 22,7 1425

35331 2 x 95 mm² 50 3883 253 42,1 2850

35332 3 x 95 mm² 50 4709 268 44,7 4275

35333 4 x 95 mm² 50 5737 295 49,1 5700

35334 5 x 95 mm² 50 6952 325 54,1 7125

35345 3 G 120 mm² - 5428 290 48,3 5400

35340 1 x 120 mm² 10 1538 147 24,5 1800

35341 2 x 120 mm² 60 4686 275 45,8 3600

35342 3 x 120 mm² 60 5688 292 48,7 5400

35343 4 x 120 mm² 60 6920 322 53,7 7200

35344 5 x 120 mm² 60 8290 356 59,3 9000

35350 1 x 150 mm² 10 1845 160 26,6 2250

35351 2 x 150 mm² 70 5563 300 50 4500

35352 3 x 150 mm² 70 6780 319 53,2 6750

35353 4 x 150 mm² 70 8301 352 58,7 9000

35354 5 x 150 mm² 70 9963 389 64,8 11250

35360 1 x 185 mm² 10 2291 175 29,1 2775

35361 2 x 185 mm² 95 7165 344 57,4 5550

35362 3 x 185 mm² 95 8764 367 61,2 8325

35363 4 x 185 mm² 95 10718 404 67,4 11100

35364 5 x 185 mm² 95 12867 446 74,3 13875

35370 1 x 240 mm² 16 2823 190 31,7 3600

35371 2 x 240 mm² 120 8921 378 63 7200

35372 3 x 240 mm² 120 10933 403 67,2 10800

35373 4 x 240 mm² 120 13471 445 74,1 14400

35374 5 x 240 mm² 120 16156 490 81,7 18000

35380 1 x 300 mm² 25 3619 221 36,8 4500

35381 2 x 300 mm² 150 10950 422 70,3 9000

35382 3 x 300 mm² 150 13542 449 74,9 13500

35383 4 x 300 mm² 150 16686 494 82,4 18000

35384 5 x 300 mm² 150 20181 545 90,9 22500

35385 1 x 400 mm² 25 4536 241 40,1 6000

35390 1 x 630 mm² 35 7048 292 48,6 9450

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 14

Page 15: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line UX P15 0,6/1 kV

Halogen Free & MUD resistant earthing & bonding wire for use on offshore topsides. Cores sizes

>25mm2 have extra flexible Class 5/6 conductors with resistance Class 2, for improved flexibility.

Characteristics Properties Unit

Product group Shipboard low voltage cable

Series Offshore cable

Type O-Line UX P15 0,6/1 kV

Standardization NEK TS 606

Conductor material Cu, tinned

Shape of conductor Round

Core insulation SHF2 MUD

Conductor category Class 2 = stranded

Core identification Colour

Colour outer sheath Green-yellow

Flame retardant In accordance with IEC 60332-1

Halogen free IEC 60754-1/2

Nominal voltage U0 0.6 kV

Nominal voltage U 1 kV

Maximum conductor temperature 90 °C

Operating temperature, flexible -20 / 70 °C

Operating temperature, fixed -40 / 70 °C

Specification See appendix

Partnumber Construction

Shapeofconductor

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35902 1 x 2,5 mm² Round 50 32 5,4 38

35903 1 x 4 mm² Round 68 35 5,9 60

35904 1 x 6 mm² Round 92 39 6,5 90

35905 1 x 10 mm² Round 136 46 7,6 150

35906 1 x 16 mm² Round 198 50 8,4 240

35907 1 x 25 mm² Round 293 61 10,1 375

35908 1 x 35 mm² Round 390 71 11,8 525

35909 1 x 50 mm² Round 517 80 13,4 750

35910 1 x 70 mm² Round 733 94 15,6 1050

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 15

Page 16: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line UX P15 0,6/1 kV

Partnumber Construction

Shapeofconductor

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35911 1 x 95 mm² Round 1000 106 17,7 1425

35912 1 x 120 mm² Round 1227 118 19,6 1800

35913 1 x 150 mm² Round 1510 130 21,7 2250

35914 1 x 185 mm² Round 1916 145 24,2 2775

35915 1 x 240 mm² Round 2436 162 27 3600

35916 1 x 300 mm² Round 3003 179 29,8 4500

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 16

Page 17: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU(i) S1/S5 250 V

Halogen Free & MUD-resistant instrumentation, communication, and monitoring & control cables for

fixed installation on offshore topsides in safe & EX-areas.. Twisted pairs/triples with individual and

overall screen of copper backed tape with tinned copper drain wire for EMI protection. Overall tinned

copper wire braid with high coverage density for EMI and mechanical protection. Different sheath

colours on request.

Characteristics Properties Unit

Product group Shipboard communication cable

Series Offshore cable

Type O-Line+ RFOU(i) S1/S5 250 V

Standardization NEK TS 606

Stranding element Article dependant, see detail sheet

Conductor category Class 2 = stranded

Core insulation Rubber (HEPR)

Core identification Numbers

Construction outer shield Tinned copper braiding

Screen over stranding element Cu/Pet foil

Screen over stranding Cu/Pet foil

Material outer sheath SHF2 MUD

Colour outer sheath Article dependant, see detail sheet

Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A

Maximum conductor temperature 90 °C

Operating temperature, flexible -20 / 70 °C

Operating temperature, fixed -40 / 70 °C

Specification See appendix

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

36700 1 x 2 x 0,75 Class 2 = stranded Blue 187 63 10,5 23

36960 1 x 2 x 0,75 Class 2 = stranded Yellow 186 63 10,5 23

35700 1 x 2 x 0,75 Class 2 = stranded Grey 186 63 10,5 23

36716 1 x 3 x 0,75 Class 2 = stranded Blue 200 65 10,8 34

35716 1 x 3 x 0,75 Class 2 = stranded Grey 200 65 10,8 34

36701 1 x 4 x 0,75 Class 2 = stranded Blue 223 69 11,5 45

35701 1 x 4 x 0,75 Class 2 = stranded Grey 223 69 11,5 45

36702 2 x 2 x 0,75 Class 2 = stranded Blue 347 89 14,8 45

36962 2 x 2 x 0,75 Class 2 = stranded Yellow 346 89 14,8 45

35702 2 x 2 x 0,75 Class 2 = stranded Grey 346 89 14,8 45

36717 2 x 3 x 0,75 Class 2 = stranded Blue 390 93 15,5 68

35717 2 x 3 x 0,75 Class 2 = stranded Grey 390 93 15,5 68

36703 4 x 2 x 0,75 Class 2 = stranded Blue 452 98 16,4 90

35703 4 x 2 x 0,75 Class 2 = stranded Grey 452 98 16,4 90

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 17

Page 18: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU(i) S1/S5 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

36718 4 x 3 x 0,75 Class 2 = stranded Blue 507 106 17,6 135

35718 4 x 3 x 0,75 Class 2 = stranded Grey 507 106 17,6 135

36704 5 x 2 x 0,75 Class 2 = stranded Blue 536 106 17,7 113

35704 5 x 2 x 0,75 Class 2 = stranded Grey 535 106 17,7 113

36705 6 x 2 x 0,75 Class 2 = stranded Blue 594 113 18,8 135

35705 6 x 2 x 0,75 Class 2 = stranded Grey 593 113 18,8 135

36706 7 x 2 x 0,75 Class 2 = stranded Blue 606 113 18,8 158

35706 7 x 2 x 0,75 Class 2 = stranded Grey 605 113 18,8 158

36719 7 x 3 x 0,75 Class 2 = stranded Blue 728 125 20,9 236

35719 7 x 3 x 0,75 Class 2 = stranded Grey 727 125 20,9 236

36707 8 x 2 x 0,75 Class 2 = stranded Blue 674 119 19,9 180

35707 8 x 2 x 0,75 Class 2 = stranded Grey 674 119 19,9 180

36720 8 x 3 x 0,75 Class 2 = stranded Blue 803 133 22,2 270

35720 8 x 3 x 0,75 Class 2 = stranded Grey 802 133 22,2 270

36708 10 x 2 x 0,75 Class 2 = stranded Blue 774 133 22,1 225

35708 10 x 2 x 0,75 Class 2 = stranded Grey 773 133 22,1 225

36709 12 x 2 x 0,75 Class 2 = stranded Blue 890 137 22,9 270

35709 12 x 2 x 0,75 Class 2 = stranded Grey 889 137 22,9 270

36721 12 x 3 x 0,75 Class 2 = stranded Blue 1068 152 25,3 405

35721 12 x 3 x 0,75 Class 2 = stranded Grey 1067 152 25,3 405

36710 14 x 2 x 0,75 Class 2 = stranded Blue 947 145 24,2 315

35710 14 x 2 x 0,75 Class 2 = stranded Grey 946 145 24,2 315

36725 16 x 2 x 0,75 Class 2 = stranded Blue 1068 153 25,5 360

35725 16 x 2 x 0,75 Class 2 = stranded Grey 1067 153 25,5 360

36722 16 x 3 x 0,75 Class 2 = stranded Blue 1300 169 28,2 540

35722 16 x 3 x 0,75 Class 2 = stranded Grey 1299 169 28,2 540

36711 19 x 2 x 0,75 Class 2 = stranded Blue 1151 163 27,1 428

35711 19 x 2 x 0,75 Class 2 = stranded Grey 1150 163 27,1 428

36723 19 x 3 x 0,75 Class 2 = stranded Blue 1398 180 30 641

35723 19 x 3 x 0,75 Class 2 = stranded Grey 1397 180 30 641

36712 24 x 2 x 0,75 Class 2 = stranded Blue 1375 178 29,7 540

35712 24 x 2 x 0,75 Class 2 = stranded Grey 1374 178 29,7 540

36724 24 x 3 x 0,75 Class 2 = stranded Blue 1705 199 33,1 810

35724 24 x 3 x 0,75 Class 2 = stranded Grey 1704 199 33,1 810

36713 27 x 2 x 0,75 Class 2 = stranded Blue 1590 187 31,2 608

35713 27 x 2 x 0,75 Class 2 = stranded Grey 1589 187 31,2 608

36714 30 x 2 x 0,75 Class 2 = stranded Blue 1634 194 32,4 675

35714 30 x 2 x 0,75 Class 2 = stranded Grey 1633 194 32,4 675

36715 37 x 2 x 0,75 Class 2 = stranded Blue 2112 219 36,5 833

35715 37 x 2 x 0,75 Class 2 = stranded Grey 2110 219 36,5 833

36730 1 x 2 x 1,5 Class 2 = stranded Blue 236 70 11,7 45

36964 1 x 2 x 1,5 Class 2 = stranded Yellow 236 70 11,7 45

35730 1 x 2 x 1,5 Class 2 = stranded Grey 236 70 11,7 45

36746 1 x 3 x 1,5 Class 2 = stranded Blue 261 74 12,3 68

35746 1 x 3 x 1,5 Class 2 = stranded Grey 261 74 12,3 68

36731 1 x 4 x 1,5 Class 2 = stranded Blue 336 82 13,7 90

35731 1 x 4 x 1,5 Class 2 = stranded Grey 335 82 13,7 90

36732 2 x 2 x 1,5 Class 2 = stranded Blue 465 104 17,4 90

36966 2 x 2 x 1,5 Class 2 = stranded Yellow 464 104 17,4 90

35732 2 x 2 x 1,5 Class 2 = stranded Grey 464 104 17,4 90

36747 2 x 3 x 1,5 Class 2 = stranded Blue 534 110 18,3 135

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 18

Page 19: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU(i) S1/S5 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35747 2 x 3 x 1,5 Class 2 = stranded Grey 534 110 18,3 135

36733 4 x 2 x 1,5 Class 2 = stranded Blue 620 117 19,5 180

35733 4 x 2 x 1,5 Class 2 = stranded Grey 619 117 19,5 180

36748 4 x 3 x 1,5 Class 2 = stranded Blue 729 126 21 270

35748 4 x 3 x 1,5 Class 2 = stranded Grey 728 126 21 270

36734 5 x 2 x 1,5 Class 2 = stranded Blue 756 127 21,1 225

35734 5 x 2 x 1,5 Class 2 = stranded Grey 755 127 21,1 225

36735 6 x 2 x 1,5 Class 2 = stranded Blue 848 136 22,6 270

35735 6 x 2 x 1,5 Class 2 = stranded Grey 848 136 22,6 270

36736 7 x 2 x 1,5 Class 2 = stranded Blue 869 136 22,6 315

35736 7 x 2 x 1,5 Class 2 = stranded Grey 869 136 22,6 315

36749 7 x 3 x 1,5 Class 2 = stranded Blue 1066 152 25,3 473

35749 7 x 3 x 1,5 Class 2 = stranded Grey 1065 152 25,3 473

36737 8 x 2 x 1,5 Class 2 = stranded Blue 961 144 24 360

35737 8 x 2 x 1,5 Class 2 = stranded Grey 960 144 24 360

36750 8 x 3 x 1,5 Class 2 = stranded Blue 1185 162 27 540

35750 8 x 3 x 1,5 Class 2 = stranded Grey 1183 162 27 540

36738 10 x 2 x 1,5 Class 2 = stranded Blue 1106 161 26,9 450

35738 10 x 2 x 1,5 Class 2 = stranded Grey 1105 161 26,9 450

36739 12 x 2 x 1,5 Class 2 = stranded Blue 1293 169 28,1 540

35739 12 x 2 x 1,5 Class 2 = stranded Grey 1292 169 28,1 540

36740 14 x 2 x 1,5 Class 2 = stranded Blue 1381 178 29,7 630

35740 14 x 2 x 1,5 Class 2 = stranded Grey 1380 178 29,7 630

36755 16 x 2 x 1,5 Class 2 = stranded Blue 1583 188 31,4 720

35755 16 x 2 x 1,5 Class 2 = stranded Grey 1373 188 31,4 720

35752 16 x 3 x 1,5 Class 2 = stranded Grey 1972 209 34,9 1080

36741 19 x 2 x 1,5 Class 2 = stranded Blue 1710 201 33,5 855

35741 19 x 2 x 1,5 Class 2 = stranded Grey 1708 201 33,5 855

36742 24 x 2 x 1,5 Class 2 = stranded Blue 2242 229 38,2 1080

35742 24 x 2 x 1,5 Class 2 = stranded Grey 2241 229 38,2 1080

35754 24 x 3 x 1,5 Class 2 = stranded Grey 2810 251 41,9 1620

36760 1 x 2 x 2,5 Class 2 = stranded Blue 289 77 12,8 75

35760 1 x 2 x 2,5 Class 2 = stranded Grey 289 77 12,8 75

36776 1 x 3 x 2,5 Class 2 = stranded Blue 355 82 13,7 113

35776 1 x 3 x 2,5 Class 2 = stranded Grey 354 82 13,7 113

36761 1 x 4 x 2,5 Class 2 = stranded Blue 408 89 14,9 150

35761 1 x 4 x 2,5 Class 2 = stranded Grey 407 89 14,9 150

36762 2 x 2 x 2,5 Class 2 = stranded Blue 564 114 19 150

35762 2 x 2 x 2,5 Class 2 = stranded Grey 563 114 19 150

36777 2 x 3 x 2,5 Class 2 = stranded Blue 661 122 20,3 225

35777 2 x 3 x 2,5 Class 2 = stranded Grey 661 122 20,3 225

36763 4 x 2 x 2,5 Class 2 = stranded Blue 781 130 21,7 300

35763 4 x 2 x 2,5 Class 2 = stranded Grey 780 130 21,7 300

36778 4 x 3 x 2,5 Class 2 = stranded Blue 928 140 23,4 450

35778 4 x 3 x 2,5 Class 2 = stranded Grey 927 140 23,4 450

36764 5 x 2 x 2,5 Class 2 = stranded Blue 964 142 23,6 375

35764 5 x 2 x 2,5 Class 2 = stranded Grey 964 142 23,6 375

36765 6 x 2 x 2,5 Class 2 = stranded Blue 1085 152 25,3 450

35765 6 x 2 x 2,5 Class 2 = stranded Grey 1084 152 25,3 450

36766 7 x 2 x 2,5 Class 2 = stranded Blue 1118 152 25,3 525

35766 7 x 2 x 2,5 Class 2 = stranded Grey 1117 152 25,3 525

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 19

Page 20: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU(i) S1/S5 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

36779 7 x 3 x 2,5 Class 2 = stranded Blue 1383 170 28,4 788

35779 7 x 3 x 2,5 Class 2 = stranded Grey 1382 170 28,4 788

36767 8 x 2 x 2,5 Class 2 = stranded Blue 1241 161 26,9 600

35767 8 x 2 x 2,5 Class 2 = stranded Grey 1240 161 26,9 600

36780 8 x 3 x 2,5 Class 2 = stranded Blue 1559 182 30,4 900

35780 8 x 3 x 2,5 Class 2 = stranded Grey 1558 182 30,4 900

36768 10 x 2 x 2,5 Class 2 = stranded Blue 1430 181 30,2 750

35768 10 x 2 x 2,5 Class 2 = stranded Grey 1429 181 30,2 750

36769 12 x 2 x 2,5 Class 2 = stranded Blue 1689 190 31,6 900

35769 12 x 2 x 2,5 Class 2 = stranded Grey 1688 190 31,6 900

36770 14 x 2 x 2,5 Class 2 = stranded Blue 1825 201 33,5 1050

35770 14 x 2 x 2,5 Class 2 = stranded Grey 1824 201 33,5 1050

36785 16 x 2 x 2,5 Class 2 = stranded Blue 2240 220 36,7 1200

35785 16 x 2 x 2,5 Class 2 = stranded Grey 2238 220 36,7 1200

36771 19 x 2 x 2,5 Class 2 = stranded Blue 2458 236 39,3 1425

35771 19 x 2 x 2,5 Class 2 = stranded Grey 2456 236 39,3 1425

36772 24 x 2 x 2,5 Class 2 = stranded Blue 2968 260 43,3 1800

35772 24 x 2 x 2,5 Class 2 = stranded Grey 2966 260 43,3 1800

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 20

Page 21: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU(c) S2/S6 250 V

Halogen Free & MUD-resistant instrumentation, communication, and monitoring & control cables for

fixed installation on offshore topsides in safe & EX-areas. Twisted pairs/triples with overall screen of

copper backed tape with tinned copper drain wire for EMI protection & Overall tinned copper wire braid

with high coverage density. Different sheath colours on request.

Characteristics Properties Unit

Product group Shipboard communication cable

Series Offshore cable

Type O-Line+ RFOU(c) S2/S6 250 V

Standardization NEK TS 606

Stranding element Article dependant, see detail sheet

Conductor category Class 2 = stranded

Core insulation Rubber (HEPR)

Core identification Numbers

Construction outer shield Tinned copper braiding

Screen over stranding Cu/Pet foil

Material outer sheath SHF2 MUD

Colour outer sheath Article dependant, see detail sheet

Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A

Maximum conductor temperature 90 °C

Operating temperature, flexible -20 / 70 °C

Operating temperature, fixed -40 / 70 °C

Specification See appendix

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

36400 1 x 2 x 0,75 Class 2 = stranded Blue 187 63 10,5 23

36900 1 x 2 x 0,75 Class 2 = stranded Yellow 186 63 10,5 23

35400 1 x 2 x 0,75 Class 2 = stranded Grey 186 63 10,5 23

36416 1 x 3 x 0,75 Class 2 = stranded Blue 202 65 10,8 34

35416 1 x 3 x 0,75 Class 2 = stranded Grey 202 65 10,8 34

36401 1 x 4 x 0,75 Class 2 = stranded Blue 223 69 11,5 45

35401 1 x 4 x 0,75 Class 2 = stranded Grey 223 69 11,5 45

36402 2 x 2 x 0,75 Class 2 = stranded Blue 310 83 13,9 45

35402 2 x 2 x 0,75 Class 2 = stranded Grey 310 83 13,9 45

36417 2 x 3 x 0,75 Class 2 = stranded Blue 351 89 14,8 68

35417 2 x 3 x 0,75 Class 2 = stranded Grey 350 89 14,8 68

36403 4 x 2 x 0,75 Class 2 = stranded Blue 395 94 15,6 90

35403 4 x 2 x 0,75 Class 2 = stranded Grey 395 94 15,6 90

36418 4 x 3 x 0,75 Class 2 = stranded Blue 450 100 16,6 135

35418 4 x 3 x 0,75 Class 2 = stranded Grey 450 100 16,6 135

36404 5 x 2 x 0,75 Class 2 = stranded Blue 453 100 16,6 113

35404 5 x 2 x 0,75 Class 2 = stranded Grey 453 100 16,6 113

36405 6 x 2 x 0,75 Class 2 = stranded Blue 525 107 17,9 135

35405 6 x 2 x 0,75 Class 2 = stranded Grey 524 107 17,9 135

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 21

Page 22: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU(c) S2/S6 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

36406 7 x 2 x 0,75 Class 2 = stranded Blue 527 107 17,9 158

35406 7 x 2 x 0,75 Class 2 = stranded Grey 527 107 17,9 158

36419 7 x 3 x 0,75 Class 2 = stranded Blue 626 118 19,7 236

35419 7 x 3 x 0,75 Class 2 = stranded Grey 626 118 19,7 236

36407 8 x 2 x 0,75 Class 2 = stranded Blue 567 112 18,7 180

35407 8 x 2 x 0,75 Class 2 = stranded Grey 567 112 18,7 180

36420 8 x 3 x 0,75 Class 2 = stranded Blue 703 126 21 270

35420 8 x 3 x 0,75 Class 2 = stranded Grey 702 126 21 270

36408 10 x 2 x 0,75 Class 2 = stranded Blue 658 124 20,7 225

35408 10 x 2 x 0,75 Class 2 = stranded Grey 658 124 20,7 225

36409 12 x 2 x 0,75 Class 2 = stranded Blue 716 129 21,5 270

35409 12 x 2 x 0,75 Class 2 = stranded Grey 715 129 21,5 270

36421 12 x 3 x 0,75 Class 2 = stranded Blue 887 143 23,8 405

35421 12 x 3 x 0,75 Class 2 = stranded Grey 886 143 23,8 405

36410 14 x 2 x 0,75 Class 2 = stranded Blue 805 137 22,8 315

35410 14 x 2 x 0,75 Class 2 = stranded Grey 804 137 22,8 315

36425 16 x 2 x 0,75 Class 2 = stranded Blue 856 143 23,8 360

35425 16 x 2 x 0,75 Class 2 = stranded Grey 856 143 23,8 360

36422 16 x 3 x 0,75 Class 2 = stranded Blue 1008 159 26,5 540

35422 16 x 3 x 0,75 Class 2 = stranded Grey 1061 159 26,5 540

36411 19 x 2 x 0,75 Class 2 = stranded Blue 957 152 25,3 428

35411 19 x 2 x 0,75 Class 2 = stranded Grey 956 152 25,3 428

36423 19 x 3 x 0,75 Class 2 = stranded Blue 1200 169 28,2 641

35423 19 x 3 x 0,75 Class 2 = stranded Grey 1199 169 28,2 641

36412 24 x 2 x 0,75 Class 2 = stranded Blue 1148 167 27,9 540

35412 24 x 2 x 0,75 Class 2 = stranded Grey 1146 167 27,9 540

36424 24 x 3 x 0,75 Class 2 = stranded Blue 1461 188 31,3 810

35424 24 x 3 x 0,75 Class 2 = stranded Grey 1459 188 31,3 810

36413 27 x 2 x 0,75 Class 2 = stranded Blue 1237 175 29,1 608

35413 27 x 2 x 0,75 Class 2 = stranded Grey 1236 175 29,1 608

36414 30 x 2 x 0,75 Class 2 = stranded Blue 1327 181 30,2 675

35414 30 x 2 x 0,75 Class 2 = stranded Grey 1326 181 30,2 675

36415 37 x 2 x 0,75 Class 2 = stranded Blue 1558 197 32,9 833

35415 37 x 2 x 0,75 Class 2 = stranded Grey 1557 197 32,9 833

36430 1 x 2 x 1,5 Class 2 = stranded Blue 236 70 11,7 45

36904 1 x 2 x 1,5 Class 2 = stranded Yellow 236 70 11,7 45

35430 1 x 2 x 1,5 Class 2 = stranded Grey 236 70 11,7 45

36446 1 x 3 x 1,5 Class 2 = stranded Blue 267 74 12,3 68

35446 1 x 3 x 1,5 Class 2 = stranded Grey 266 74 12,3 68

36431 1 x 4 x 1,5 Class 2 = stranded Blue 336 82 13,7 90

35431 1 x 4 x 1,5 Class 2 = stranded Grey 335 82 13,7 90

36432 2 x 2 x 1,5 Class 2 = stranded Blue 418 98 16,3 90

36906 2 x 2 x 1,5 Class 2 = stranded Yellow 418 98 16,3 90

35432 2 x 2 x 1,5 Class 2 = stranded Grey 417 98 16,3 90

36447 2 x 3 x 1,5 Class 2 = stranded Blue 487 105 17,5 135

35447 2 x 3 x 1,5 Class 2 = stranded Grey 486 105 17,5 135

36433 4 x 2 x 1,5 Class 2 = stranded Blue 556 111 18,5 180

35433 4 x 2 x 1,5 Class 2 = stranded Grey 556 111 18,5 180

36448 4 x 3 x 1,5 Class 2 = stranded Blue 657 120 20 270

35448 4 x 3 x 1,5 Class 2 = stranded Grey 656 120 20 270

36434 5 x 2 x 1,5 Class 2 = stranded Blue 646 120 20 225

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 22

Page 23: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU(c) S2/S6 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35434 5 x 2 x 1,5 Class 2 = stranded Grey 645 120 20 225

36435 6 x 2 x 1,5 Class 2 = stranded Blue 758 128 21,4 270

35435 6 x 2 x 1,5 Class 2 = stranded Grey 757 128 21,4 270

36436 7 x 2 x 1,5 Class 2 = stranded Blue 906 128 21,4 315

35436 7 x 2 x 1,5 Class 2 = stranded Grey 906 128 21,4 315

36449 7 x 3 x 1,5 Class 2 = stranded Blue 963 145 24,2 473

35449 7 x 3 x 1,5 Class 2 = stranded Grey 962 145 24,2 473

36437 8 x 2 x 1,5 Class 2 = stranded Blue 849 136 22,7 360

35437 8 x 2 x 1,5 Class 2 = stranded Grey 848 136 22,7 360

36450 8 x 3 x 1,5 Class 2 = stranded Blue 1082 155 25,8 540

35450 8 x 3 x 1,5 Class 2 = stranded Grey 1081 155 25,8 540

36438 10 x 2 x 1,5 Class 2 = stranded Blue 990 152 25,3 450

35438 10 x 2 x 1,5 Class 2 = stranded Grey 989 152 25,3 450

36439 12 x 2 x 1,5 Class 2 = stranded Blue 1090 158 26,3 540

35439 12 x 2 x 1,5 Class 2 = stranded Grey 1089 158 26,3 540

36440 14 x 2 x 1,5 Class 2 = stranded Blue 1216 166 27,7 630

35440 14 x 2 x 1,5 Class 2 = stranded Grey 1215 166 27,7 630

36455 16 x 2 x 1,5 Class 2 = stranded Blue 1322 176 29,3 720

35455 16 x 2 x 1,5 Class 2 = stranded Grey 1321 176 29,3 720

36441 19 x 2 x 1,5 Class 2 = stranded Blue 1487 187 31,2 855

35441 19 x 2 x 1,5 Class 2 = stranded Grey 1485 187 31,2 855

36442 24 x 2 x 1,5 Class 2 = stranded Blue 1799 207 34,5 1080

35442 24 x 2 x 1,5 Class 2 = stranded Grey 1798 207 34,5 1080

36460 1 x 2 x 2,5 Class 2 = stranded Blue 289 77 12,8 75

35460 1 x 2 x 2,5 Class 2 = stranded Grey 289 77 12,8 75

36476 1 x 3 x 2,5 Class 2 = stranded Blue 356 82 13,7 113

35476 1 x 3 x 2,5 Class 2 = stranded Grey 356 82 13,7 113

36461 1 x 4 x 2,5 Class 2 = stranded Blue 408 89 14,9 150

35461 1 x 4 x 2,5 Class 2 = stranded Grey 407 89 14,9 150

36462 2 x 2 x 2,5 Class 2 = stranded Blue 513 109 18,1 150

35462 2 x 2 x 2,5 Class 2 = stranded Grey 512 109 18,1 150

36477 2 x 3 x 2,5 Class 2 = stranded Blue 604 115 19,2 225

35477 2 x 3 x 2,5 Class 2 = stranded Grey 603 115 19,2 225

36463 4 x 2 x 2,5 Class 2 = stranded Blue 718 124 20,7 300

35463 4 x 2 x 2,5 Class 2 = stranded Grey 718 124 20,7 300

36478 4 x 3 x 2,5 Class 2 = stranded Blue 830 133 22,1 450

35478 4 x 3 x 2,5 Class 2 = stranded Grey 830 133 22,1 450

36464 5 x 2 x 2,5 Class 2 = stranded Blue 825 133 22,1 375

35464 5 x 2 x 2,5 Class 2 = stranded Grey 825 133 22,1 375

36465 6 x 2 x 2,5 Class 2 = stranded Blue 960 143 23,9 450

35465 6 x 2 x 2,5 Class 2 = stranded Grey 959 143 23,9 450

36466 7 x 2 x 2,5 Class 2 = stranded Blue 989 143 23,9 525

35466 7 x 2 x 2,5 Class 2 = stranded Grey 988 143 23,9 525

36479 7 x 3 x 2,5 Class 2 = stranded Blue 1241 161 26,9 788

35479 7 x 3 x 2,5 Class 2 = stranded Grey 1240 161 26,9 788

36467 8 x 2 x 2,5 Class 2 = stranded Blue 1107 152 25,3 600

35467 8 x 2 x 2,5 Class 2 = stranded Grey 1106 152 25,3 600

36480 8 x 3 x 2,5 Class 2 = stranded Blue 1398 172 28,7 900

35480 8 x 3 x 2,5 Class 2 = stranded Grey 1397 172 28,7 900

36468 10 x 2 x 2,5 Class 2 = stranded Blue 1295 172 28,6 750

35468 10 x 2 x 2,5 Class 2 = stranded Grey 1293 172 28,6 750

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 23

Page 24: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ RFOU(c) S2/S6 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

36469 12 x 2 x 2,5 Class 2 = stranded Blue 1421 177 29,5 900

35469 12 x 2 x 2,5 Class 2 = stranded Grey 1419 177 29,5 900

36470 14 x 2 x 2,5 Class 2 = stranded Blue 1611 188 31,4 1050

35470 14 x 2 x 2,5 Class 2 = stranded Grey 1610 188 31,4 1050

36485 16 x 2 x 2,5 Class 2 = stranded Blue 1743 198 33 1200

35485 16 x 2 x 2,5 Class 2 = stranded Grey 1742 198 33 1200

36471 19 x 2 x 2,5 Class 2 = stranded Blue 2161 220 36,6 1425

35471 19 x 2 x 2,5 Class 2 = stranded Grey 2159 220 36,6 1425

36472 24 x 2 x 2,5 Class 2 = stranded Blue 2609 242 40,4 1800

35472 24 x 2 x 2,5 Class 2 = stranded Grey 2607 242 40,4 1800

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 24

Page 25: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU(i) S3/S7 250 V

Fire Resistant, Halogen Free & MUD-resistant instrumentation, communication, and monitoring &

control cables for fixed installation on offshore topsides in safe & EX-areas.. Twisted pairs/triples with

individual and overall screen of copper backed tape with tinned copper drain wire for EMI protection.

Overall tinned copper wire braid with high coverage density for EMI and mechanical protection. Meets

the fire resistant standards set both by the IEC 60331-21 and the more demanding 60331- 1/ 2 (2009)

specification for use in areas where circuit integrity in fire conditions is required. Different sheath colours

on request.

Characteristics Properties Unit

Product group Shipboard communication cable

Series Offshore cable

Type O-Line+ BFOU(i) S3/S7 250 V

Standardization NEK TS 606

Stranding element Article dependant, see detail sheet

Conductor category Class 2 = stranded

Core insulation Mica + HEPR

Core identification Numbers

Construction outer shield Tinned copper braiding

Screen over stranding element Cu/Pet foil

Screen over stranding Cu/Pet foil

Material outer sheath SHF2 MUD

Colour outer sheath Article dependant, see detail sheet

Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A

Insulation integrity in accordance with IEC 60331 Yes

Maximum conductor temperature 90 °C

Operating temperature, flexible -20 / 70 °C

Operating temperature, fixed -40 / 70 °C

Specification See appendix

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

36600 1 x 2 x 0,75 Class 2 = stranded Blue 206 67 11,1 23

36940 1 x 2 x 0,75 Class 2 = stranded Yellow 206 67 11,1 23

35600 1 x 2 x 0,75 Class 2 = stranded Grey 206 67 11,1 23

36616 1 x 3 x 0,75 Class 2 = stranded Blue 228 70 11,7 34

35616 1 x 3 x 0,75 Class 2 = stranded Grey 227 70 11,7 34

36601 1 x 4 x 0,75 Class 2 = stranded Blue 261 76 12,6 45

35601 1 x 4 x 0,75 Class 2 = stranded Grey 261 76 12,6 45

36602 2 x 2 x 0,75 Class 2 = stranded Blue 400 96 16 45

36942 2 x 2 x 0,75 Class 2 = stranded Yellow 400 96 16 45

35602 2 x 2 x 0,75 Class 2 = stranded Grey 400 96 16 45

36617 2 x 3 x 0,75 Class 2 = stranded Blue 464 102 17 68

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 25

Page 26: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU(i) S3/S7 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35617 2 x 3 x 0,75 Class 2 = stranded Grey 463 102 17 68

36603 4 x 2 x 0,75 Class 2 = stranded Blue 541 109 18,1 90

35603 4 x 2 x 0,75 Class 2 = stranded Grey 541 109 18,1 90

36618 4 x 3 x 0,75 Class 2 = stranded Blue 625 117 19,5 135

35618 4 x 3 x 0,75 Class 2 = stranded Grey 624 117 19,5 135

36604 5 x 2 x 0,75 Class 2 = stranded Blue 641 118 19,6 113

35604 5 x 2 x 0,75 Class 2 = stranded Grey 640 118 19,6 113

36605 6 x 2 x 0,75 Class 2 = stranded Blue 735 125 20,9 135

35605 6 x 2 x 0,75 Class 2 = stranded Grey 735 125 20,9 135

36606 7 x 2 x 0,75 Class 2 = stranded Blue 746 125 20,9 158

35606 7 x 2 x 0,75 Class 2 = stranded Grey 745 125 20,9 158

36619 7 x 3 x 0,75 Class 2 = stranded Blue 895 140 23,3 236

35619 7 x 3 x 0,75 Class 2 = stranded Grey 894 140 23,3 236

36607 8 x 2 x 0,75 Class 2 = stranded Blue 821 133 22,1 180

35607 8 x 2 x 0,75 Class 2 = stranded Grey 820 133 22,1 180

36620 8 x 3 x 0,75 Class 2 = stranded Blue 991 149 24,8 270

35620 8 x 3 x 0,75 Class 2 = stranded Grey 990 149 24,8 270

36608 10 x 2 x 0,75 Class 2 = stranded Blue 948 148 24,7 225

35608 10 x 2 x 0,75 Class 2 = stranded Grey 947 148 24,7 225

36609 12 x 2 x 0,75 Class 2 = stranded Blue 1063 154 25,6 270

35609 12 x 2 x 0,75 Class 2 = stranded Grey 1062 154 25,6 270

36621 12 x 3 x 0,75 Class 2 = stranded Blue 1269 170 28,4 405

35621 12 x 3 x 0,75 Class 2 = stranded Grey 1268 170 28,4 405

36610 14 x 2 x 0,75 Class 2 = stranded Blue 1167 163 27,1 315

35610 14 x 2 x 0,75 Class 2 = stranded Grey 1166 163 27,1 315

36625 16 x 2 x 0,75 Class 2 = stranded Blue 1317 172 28,6 360

35625 16 x 2 x 0,75 Class 2 = stranded Grey 1316 172 28,6 360

36622 16 x 3 x 0,75 Class 2 = stranded Blue 1546 190 31,7 540

35622 16 x 3 x 0,75 Class 2 = stranded Grey 1544 190 31,7 540

36611 19 x 2 x 0,75 Class 2 = stranded Blue 1437 182 30,4 428

35611 19 x 2 x 0,75 Class 2 = stranded Grey 1436 182 30,4 428

36623 19 x 3 x 0,75 Class 2 = stranded Blue 1793 204 34 641

35623 19 x 3 x 0,75 Class 2 = stranded Grey 1791 204 34 641

36612 24 x 2 x 0,75 Class 2 = stranded Blue 1726 202 33,6 540

35612 24 x 2 x 0,75 Class 2 = stranded Grey 1725 202 33,6 540

36624 24 x 3 x 0,75 Class 2 = stranded Blue 2355 233 38,8 810

35624 24 x 3 x 0,75 Class 2 = stranded Grey 2353 233 38,8 810

36613 27 x 2 x 0,75 Class 2 = stranded Blue 2001 218 36,3 608

35613 27 x 2 x 0,75 Class 2 = stranded Grey 1999 218 36,3 608

36614 30 x 2 x 0,75 Class 2 = stranded Blue 2246 228 38 675

35614 30 x 2 x 0,75 Class 2 = stranded Grey 2244 228 38 675

36615 37 x 2 x 0,75 Class 2 = stranded Blue 2643 248 41,3 833

35615 37 x 2 x 0,75 Class 2 = stranded Grey 2640 248 41,3 833

36630 1 x 2 x 1,5 Class 2 = stranded Blue 264 74 12,4 45

36944 1 x 2 x 1,5 Class 2 = stranded Yellow 264 74 12,4 45

35630 1 x 2 x 1,5 Class 2 = stranded Grey 264 74 12,4 45

36646 1 x 3 x 1,5 Class 2 = stranded Blue 321 81 13,5 68

35646 1 x 3 x 1,5 Class 2 = stranded Grey 321 81 13,5 68

36631 1 x 4 x 1,5 Class 2 = stranded Blue 375 88 14,7 90

35631 1 x 4 x 1,5 Class 2 = stranded Grey 375 88 14,7 90

36632 2 x 2 x 1,5 Class 2 = stranded Blue 527 112 18,6 90

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 26

Page 27: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU(i) S3/S7 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

36946 2 x 2 x 1,5 Class 2 = stranded Yellow 526 112 18,6 90

35632 2 x 2 x 1,5 Class 2 = stranded Grey 526 112 18,6 90

36647 2 x 3 x 1,5 Class 2 = stranded Blue 623 119 19,9 135

35647 2 x 3 x 1,5 Class 2 = stranded Grey 622 119 19,9 135

36633 4 x 2 x 1,5 Class 2 = stranded Blue 732 127 21,2 180

35633 4 x 2 x 1,5 Class 2 = stranded Grey 731 127 21,2 180

36648 4 x 3 x 1,5 Class 2 = stranded Blue 861 137 22,9 270

35648 4 x 3 x 1,5 Class 2 = stranded Grey 860 137 22,9 270

36634 5 x 2 x 1,5 Class 2 = stranded Blue 865 138 23 225

35634 5 x 2 x 1,5 Class 2 = stranded Grey 864 138 23 225

36635 6 x 2 x 1,5 Class 2 = stranded Blue 991 148 24,7 270

35635 6 x 2 x 1,5 Class 2 = stranded Grey 990 148 24,7 270

36636 7 x 2 x 1,5 Class 2 = stranded Blue 1019 148 24,7 315

35636 7 x 2 x 1,5 Class 2 = stranded Grey 1018 148 24,7 315

36649 7 x 3 x 1,5 Class 2 = stranded Blue 1260 166 27,7 473

35649 7 x 3 x 1,5 Class 2 = stranded Grey 1258 166 27,7 473

36637 8 x 2 x 1,5 Class 2 = stranded Blue 1142 157 26,2 360

35637 8 x 2 x 1,5 Class 2 = stranded Grey 1141 157 26,2 360

36650 8 x 3 x 1,5 Class 2 = stranded Blue 1405 178 29,6 540

35650 8 x 3 x 1,5 Class 2 = stranded Grey 1404 178 29,6 540

36638 10 x 2 x 1,5 Class 2 = stranded Blue 1322 176 29,4 450

35638 10 x 2 x 1,5 Class 2 = stranded Grey 1321 176 29,4 450

36639 12 x 2 x 1,5 Class 2 = stranded Blue 1474 185 30,8 540

35639 12 x 2 x 1,5 Class 2 = stranded Grey 1472 185 30,8 540

36640 14 x 2 x 1,5 Class 2 = stranded Blue 1665 196 32,6 630

35640 14 x 2 x 1,5 Class 2 = stranded Grey 1664 196 32,6 630

36655 16 x 2 x 1,5 Class 2 = stranded Blue 1781 207 34,5 720

35655 16 x 2 x 1,5 Class 2 = stranded Grey 1780 207 34,5 720

36641 19 x 2 x 1,5 Class 2 = stranded Blue 2253 230 38,3 855

35641 19 x 2 x 1,5 Class 2 = stranded Grey 2252 230 38,3 855

36642 24 x 2 x 1,5 Class 2 = stranded Blue 2723 253 42,2 1080

35642 24 x 2 x 1,5 Class 2 = stranded Grey 2720 253 42,2 1080

36660 1 x 2 x 2,5 Class 2 = stranded Blue 350 83 13,9 75

35660 1 x 2 x 2,5 Class 2 = stranded Grey 350 83 13,9 75

36676 1 x 3 x 2,5 Class 2 = stranded Blue 378 86 14,4 113

35676 1 x 3 x 2,5 Class 2 = stranded Grey 378 86 14,4 113

36661 1 x 4 x 2,5 Class 2 = stranded Blue 447 95 15,8 150

35661 1 x 4 x 2,5 Class 2 = stranded Grey 447 95 15,8 150

36662 2 x 2 x 2,5 Class 2 = stranded Blue 651 123 20,5 150

35662 2 x 2 x 2,5 Class 2 = stranded Grey 650 123 20,5 150

36677 2 x 3 x 2,5 Class 2 = stranded Blue 763 130 21,7 225

35677 2 x 3 x 2,5 Class 2 = stranded Grey 762 130 21,7 225

36663 4 x 2 x 2,5 Class 2 = stranded Blue 908 140 23,4 300

35663 4 x 2 x 2,5 Class 2 = stranded Grey 908 140 23,4 300

36678 4 x 3 x 2,5 Class 2 = stranded Blue 1096 152 25,3 450

35678 4 x 3 x 2,5 Class 2 = stranded Grey 1095 152 25,3 450

36664 5 x 2 x 2,5 Class 2 = stranded Blue 1065 152 25,3 375

35664 5 x 2 x 2,5 Class 2 = stranded Grey 1064 152 25,3 375

36665 6 x 2 x 2,5 Class 2 = stranded Blue 1246 164 27,4 450

35665 6 x 2 x 2,5 Class 2 = stranded Grey 1245 164 27,4 450

36666 7 x 2 x 2,5 Class 2 = stranded Blue 1288 164 27,4 525

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 27

Page 28: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU(i) S3/S7 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35666 7 x 2 x 2,5 Class 2 = stranded Grey 1287 164 27,4 525

36679 7 x 3 x 2,5 Class 2 = stranded Blue 1632 185 30,8 788

35679 7 x 3 x 2,5 Class 2 = stranded Grey 1631 185 30,8 788

36667 8 x 2 x 2,5 Class 2 = stranded Blue 1447 175 29,1 600

35667 8 x 2 x 2,5 Class 2 = stranded Grey 1446 175 29,1 600

36680 8 x 3 x 2,5 Class 2 = stranded Blue 1826 197 32,9 900

35680 8 x 3 x 2,5 Class 2 = stranded Grey 1824 197 32,9 900

36668 10 x 2 x 2,5 Class 2 = stranded Blue 1698 198 33 750

35668 10 x 2 x 2,5 Class 2 = stranded Grey 1697 198 33 750

36669 12 x 2 x 2,5 Class 2 = stranded Blue 1873 206 34,3 900

35669 12 x 2 x 2,5 Class 2 = stranded Grey 1871 206 34,3 900

36670 14 x 2 x 2,5 Class 2 = stranded Blue 2340 227 37,8 1050

35670 14 x 2 x 2,5 Class 2 = stranded Grey 2338 227 37,8 1050

36685 16 x 2 x 2,5 Class 2 = stranded Blue 2470 238 39,7 1200

35685 16 x 2 x 2,5 Class 2 = stranded Grey 2469 238 39,7 1200

36671 19 x 2 x 2,5 Class 2 = stranded Blue 2877 256 42,6 1425

35671 19 x 2 x 2,5 Class 2 = stranded Grey 2875 256 42,6 1425

36672 24 x 2 x 2,5 Class 2 = stranded Blue 3520 283 47,2 1800

35672 24 x 2 x 2,5 Class 2 = stranded Grey 3518 283 47,2 1800

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 28

Page 29: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU(c) S4/S8 250 V

Fire Resistant, Halogen Free & MUD-resistant instrumentation, communication, and monitoring &

control cables for fixed installation on offshore in safe & EX-areas. Twisted pairs/triples with overall

screen of copper backed tape with tinned copper drain wire for EMI protection & overall tinned copper

wire braid with high coverage density. Meets the fire resistant standards set both by the IEC 60331-21

and the more demanding 60331- 1/ 2 (2009) specification for use in areas where circuit integrity in fire

conditions is required. Different sheath colours on request.

Characteristics Properties Unit

Product group Shipboard communication cable

Series Offshore cable

Type O-Line+ BFOU(c) S4/S8 250 V

Standardization NEK TS 606

Stranding element Article dependant, see detail sheet

Conductor category Class 2 = stranded

Core insulation Mica + HEPR

Core identification Numbers

Construction outer shield Tinned copper braiding

Screen over stranding Cu/Pet foil

Material outer sheath SHF2 MUD

Colour outer sheath Article dependant, see detail sheet

Flame retardant IEC 60332-1 / IEC 60332-3-22 Cat. A

Insulation integrity in accordance with IEC 60331 Yes

Maximum conductor temperature 90 °C

Operating temperature, flexible -20 / 70 °C

Operating temperature, fixed -40 / 70 °C

Specification See appendix

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

36500 1 x 2 x 0,75 Class 2 = stranded Blue 206 67 11,1 23

36920 1 x 2 x 0,75 Class 2 = stranded Yellow 206 67 11,1 23

35500 1 x 2 x 0,75 Class 2 = stranded Grey 206 67 11,1 23

36516 1 x 3 x 0,75 Class 2 = stranded Blue 228 70 11,7 34

35516 1 x 3 x 0,75 Class 2 = stranded Grey 228 70 11,7 34

36501 1 x 4 x 0,75 Class 2 = stranded Blue 261 76 12,6 45

35501 1 x 4 x 0,75 Class 2 = stranded Grey 261 76 12,6 45

36502 2 x 2 x 0,75 Class 2 = stranded Blue 365 92 15,3 45

35502 2 x 2 x 0,75 Class 2 = stranded Grey 364 92 15,3 45

36517 2 x 3 x 0,75 Class 2 = stranded Blue 405 97 16,1 68

35517 2 x 3 x 0,75 Class 2 = stranded Grey 405 97 16,1 68

36503 4 x 2 x 0,75 Class 2 = stranded Blue 472 103 17,2 90

35503 4 x 2 x 0,75 Class 2 = stranded Grey 471 103 17,2 90

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 29

Page 30: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU(c) S4/S8 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

36518 4 x 3 x 0,75 Class 2 = stranded Blue 535 110 18,4 135

35518 4 x 3 x 0,75 Class 2 = stranded Grey 535 110 18,4 135

36504 5 x 2 x 0,75 Class 2 = stranded Blue 546 110 18,4 113

35504 5 x 2 x 0,75 Class 2 = stranded Grey 545 110 18,4 113

36505 6 x 2 x 0,75 Class 2 = stranded Blue 631 119 19,8 135

35505 6 x 2 x 0,75 Class 2 = stranded Grey 630 119 19,8 135

36506 7 x 2 x 0,75 Class 2 = stranded Blue 635 119 19,8 158

35506 7 x 2 x 0,75 Class 2 = stranded Grey 634 119 19,8 158

36519 7 x 3 x 0,75 Class 2 = stranded Blue 755 132 22 236

35519 7 x 3 x 0,75 Class 2 = stranded Grey 754 132 22 236

36507 8 x 2 x 0,75 Class 2 = stranded Blue 700 125 20,8 180

35507 8 x 2 x 0,75 Class 2 = stranded Grey 700 125 20,8 180

36520 8 x 3 x 0,75 Class 2 = stranded Blue 846 140 23,4 270

35520 8 x 3 x 0,75 Class 2 = stranded Grey 845 140 23,4 270

36508 10 x 2 x 0,75 Class 2 = stranded Blue 825 140 23,3 225

35508 10 x 2 x 0,75 Class 2 = stranded Grey 825 140 23,3 225

36509 12 x 2 x 0,75 Class 2 = stranded Blue 875 144 24 270

35509 12 x 2 x 0,75 Class 2 = stranded Grey 874 144 24 270

36521 12 x 3 x 0,75 Class 2 = stranded Blue 1074 160 26,7 405

35521 12 x 3 x 0,75 Class 2 = stranded Grey 1073 160 26,7 405

36510 14 x 2 x 0,75 Class 2 = stranded Blue 986 153 25,5 315

35510 14 x 2 x 0,75 Class 2 = stranded Grey 985 153 25,5 315

36525 16 x 2 x 0,75 Class 2 = stranded Blue 1020 160 26,7 360

35525 16 x 2 x 0,75 Class 2 = stranded Grey 1019 160 26,7 360

36522 16 x 3 x 0,75 Class 2 = stranded Blue 1220 179 29,8 540

35522 16 x 3 x 0,75 Class 2 = stranded Grey 1218 179 29,8 540

36511 19 x 2 x 0,75 Class 2 = stranded Blue 1205 173 28,8 428

35511 19 x 2 x 0,75 Class 2 = stranded Grey 1204 173 28,8 428

36523 19 x 3 x 0,75 Class 2 = stranded Blue 1473 191 31,9 641

35523 19 x 3 x 0,75 Class 2 = stranded Grey 1471 191 31,9 641

36512 24 x 2 x 0,75 Class 2 = stranded Blue 1431 189 31,5 540

35512 24 x 2 x 0,75 Class 2 = stranded Grey 1430 189 31,5 540

36524 24 x 3 x 0,75 Class 2 = stranded Blue 1952 219 36,5 810

35524 24 x 3 x 0,75 Class 2 = stranded Grey 1950 219 36,5 810

36513 27 x 2 x 0,75 Class 2 = stranded Blue 1548 197 32,9 608

35513 27 x 2 x 0,75 Class 2 = stranded Grey 1546 197 32,9 608

36514 30 x 2 x 0,75 Class 2 = stranded Blue 1680 205 34,2 675

35514 30 x 2 x 0,75 Class 2 = stranded Grey 1678 205 34,2 675

36515 37 x 2 x 0,75 Class 2 = stranded Blue 2150 231 38,5 833

35515 37 x 2 x 0,75 Class 2 = stranded Grey 2148 231 38,5 833

36530 1 x 2 x 1,5 Class 2 = stranded Blue 270 76 12,6 45

36924 1 x 2 x 1,5 Class 2 = stranded Yellow 269 76 12,6 45

35530 1 x 2 x 1,5 Class 2 = stranded Grey 269 76 12,6 45

36546 1 x 3 x 1,5 Class 2 = stranded Blue 322 81 13,5 68

35546 1 x 3 x 1,5 Class 2 = stranded Grey 322 81 13,5 68

36531 1 x 4 x 1,5 Class 2 = stranded Blue 375 88 14,7 90

35531 1 x 4 x 1,5 Class 2 = stranded Grey 375 88 14,7 90

36532 2 x 2 x 1,5 Class 2 = stranded Blue 482 107 17,9 90

36926 2 x 2 x 1,5 Class 2 = stranded Yellow 481 107 17,9 90

35532 2 x 2 x 1,5 Class 2 = stranded Grey 481 107 17,9 90

36547 2 x 3 x 1,5 Class 2 = stranded Blue 539 112 18,7 135

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 30

Page 31: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU(c) S4/S8 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

35547 2 x 3 x 1,5 Class 2 = stranded Grey 539 112 18,7 135

36533 4 x 2 x 1,5 Class 2 = stranded Blue 627 120 20 180

35533 4 x 2 x 1,5 Class 2 = stranded Grey 626 120 20 180

36548 4 x 3 x 1,5 Class 2 = stranded Blue 735 130 21,6 270

35548 4 x 3 x 1,5 Class 2 = stranded Grey 734 130 21,6 270

36534 5 x 2 x 1,5 Class 2 = stranded Blue 739 130 21,6 225

35534 5 x 2 x 1,5 Class 2 = stranded Grey 738 130 21,6 225

36535 6 x 2 x 1,5 Class 2 = stranded Blue 859 140 23,3 270

35535 6 x 2 x 1,5 Class 2 = stranded Grey 858 140 23,3 270

36536 7 x 2 x 1,5 Class 2 = stranded Blue 874 140 23,3 315

35536 7 x 2 x 1,5 Class 2 = stranded Grey 873 140 23,3 315

36549 7 x 3 x 1,5 Class 2 = stranded Blue 1080 158 26,3 473

35549 7 x 3 x 1,5 Class 2 = stranded Grey 1079 158 26,3 473

36537 8 x 2 x 1,5 Class 2 = stranded Blue 965 148 24,7 360

35537 8 x 2 x 1,5 Class 2 = stranded Grey 964 148 24,7 360

36550 8 x 3 x 1,5 Class 2 = stranded Blue 1212 168 28 540

35550 8 x 3 x 1,5 Class 2 = stranded Grey 1211 168 28 540

36538 10 x 2 x 1,5 Class 2 = stranded Blue 1111 166 27,7 450

35538 10 x 2 x 1,5 Class 2 = stranded Grey 1110 166 27,7 450

36539 12 x 2 x 1,5 Class 2 = stranded Blue 1238 173 28,8 540

35539 12 x 2 x 1,5 Class 2 = stranded Grey 1236 173 28,8 540

36540 14 x 2 x 1,5 Class 2 = stranded Blue 1396 184 30,6 630

35540 14 x 2 x 1,5 Class 2 = stranded Grey 1395 184 30,6 630

36555 16 x 2 x 1,5 Class 2 = stranded Blue 1500 193 32,2 720

35555 16 x 2 x 1,5 Class 2 = stranded Grey 1499 193 32,2 720

36541 19 x 2 x 1,5 Class 2 = stranded Blue 1702 207 34,5 855

35541 19 x 2 x 1,5 Class 2 = stranded Grey 1700 207 34,5 855

36542 24 x 2 x 1,5 Class 2 = stranded Blue 2235 236 39,3 1080

35542 24 x 2 x 1,5 Class 2 = stranded Grey 2233 236 39,3 1080

36560 1 x 2 x 2,5 Class 2 = stranded Blue 350 83 13,9 75

35560 1 x 2 x 2,5 Class 2 = stranded Grey 350 83 13,9 75

36576 1 x 3 x 2,5 Class 2 = stranded Blue 378 86 14,4 113

35576 1 x 3 x 2,5 Class 2 = stranded Grey 378 86 14,4 113

36561 1 x 4 x 2,5 Class 2 = stranded Blue 439 95 15,8 150

35561 1 x 4 x 2,5 Class 2 = stranded Grey 439 95 15,8 150

36562 2 x 2 x 2,5 Class 2 = stranded Blue 561 115 19,2 150

35562 2 x 2 x 2,5 Class 2 = stranded Grey 560 115 19,2 150

36577 2 x 3 x 2,5 Class 2 = stranded Blue 675 124 20,6 225

35577 2 x 3 x 2,5 Class 2 = stranded Grey 674 124 20,6 225

36563 4 x 2 x 2,5 Class 2 = stranded Blue 771 131 21,9 300

35563 4 x 2 x 2,5 Class 2 = stranded Grey 770 131 21,9 300

36578 4 x 3 x 2,5 Class 2 = stranded Blue 925 143 23,8 450

35578 4 x 3 x 2,5 Class 2 = stranded Grey 924 143 23,8 450

36564 5 x 2 x 2,5 Class 2 = stranded Blue 926 143 23,8 375

35564 5 x 2 x 2,5 Class 2 = stranded Grey 925 143 23,8 375

36565 6 x 2 x 2,5 Class 2 = stranded Blue 1088 156 26 450

35565 6 x 2 x 2,5 Class 2 = stranded Grey 1087 156 26 450

36566 7 x 2 x 2,5 Class 2 = stranded Blue 1119 156 26 525

35566 7 x 2 x 2,5 Class 2 = stranded Grey 1118 156 26 525

36579 7 x 3 x 2,5 Class 2 = stranded Blue 1387 175 29,2 788

35579 7 x 3 x 2,5 Class 2 = stranded Grey 1385 175 29,2 788

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 31

Page 32: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Offshore

O-Line+ BFOU(c) S4/S8 250 V

Partnumber ConstructionConductorcategory

Colouroutersheath

Netweight(kg/km)

Bendingradiusafterinstallation(mm)

Outerdiameterapprox.(mm)

Tensileload(N)

36567 8 x 2 x 2,5 Class 2 = stranded Blue 1220 164 27,4 600

35567 8 x 2 x 2,5 Class 2 = stranded Grey 1219 164 27,4 600

36580 8 x 3 x 2,5 Class 2 = stranded Blue 1572 188 31,3 900

35580 8 x 3 x 2,5 Class 2 = stranded Grey 1571 188 31,3 900

36568 10 x 2 x 2,5 Class 2 = stranded Blue 1432 185 30,8 750

35568 10 x 2 x 2,5 Class 2 = stranded Grey 1431 185 30,8 750

36569 12 x 2 x 2,5 Class 2 = stranded Blue 1587 192 32 900

35569 12 x 2 x 2,5 Class 2 = stranded Grey 1586 192 32 900

36570 14 x 2 x 2,5 Class 2 = stranded Blue 1800 205 34,1 1050

35570 14 x 2 x 2,5 Class 2 = stranded Grey 1798 205 34,1 1050

36585 16 x 2 x 2,5 Class 2 = stranded Blue 2450 223 37,1 1200

35585 16 x 2 x 2,5 Class 2 = stranded Grey 2449 223 37,1 1200

36571 19 x 2 x 2,5 Class 2 = stranded Blue 2403 238 39,7 1425

35571 19 x 2 x 2,5 Class 2 = stranded Grey 2402 238 39,7 1425

36572 24 x 2 x 2,5 Class 2 = stranded Blue 2924 264 44 1800

35572 24 x 2 x 2,5 Class 2 = stranded Grey 2922 264 44 1800

Copyright (c) TKF, 22-11-2013 Subject to technical alterations Page 32

Page 33: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Version: PN-M05J12 Subject to technical alterations Page 1 / 8This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of theinformation. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information includingincorrect translation of the information by third parties.

Offshore Cables NEK606 TS-2009

Technical Product information

General DesignAll TKF O-Line+ offshore cables are constructedaccording to the latest NEK-606 and IEC 60092standards.TKF took great care to provide cableswith the best installabillity and safety propertiespossible, resulting in very flexible cables , nounneeded extra layers of foils that make strippingthe cable time consuming, and a choice formaterials with superior qualities.

Materials & Construction

ConductorsAll conductors consist of stranded tinned copperconductors with a resistance according to Class 2off IEC 60228. For the stranding we chose a finestranded design with a much better flexibilitythen standard class 2 conductors.

InsulationAll offshore cables are insulated with EPR, crosslinked Ethylene propylene rubber, according toIEC 60092-351, type HF-EPR. This material allowsa continuous conductor temperature of 90 °C andwithstands a temporary overload temperature of130 °C and a short-circuit temperature of 250 °C.The Fire-Resistant cables have conductors fullywrapped in mica-glass tape before being insulatedwith EPR insulation.

Bedding/Inner coveringAll RFOU & BFOU type offshore cables have ahalogen free bedding material over the cores,with excellent properties on both gas-tightnessand easy stripability

Armouring/BraidingAll O-Line+ RFOU & BFOU cables have tinned-copper wire braiding in compliance with IEC60092-350, which can also be used as PE becauseof a sufficient cross section according to the IEC60092-352 rules. The tinned wires give a highcorrosion resistance of the braid and offer bothmechanical and EMI protection.

ScreeningThe ( C ) type cables have twisted pairs overallscreened with Copper-PET Foil with minimumoverlap 25% and a tinned copper stranded drainwire. The ( I ) type cables have twisted pairsindividually screened with Copper-PET Foil withminimum overlap 25% and and a tinned copperstranded drain wire, and an overall screen ofcopper-PET foil with drain wire.

SheathingAll TKF O-Line+ cables have a thermosettingcross-linked outer sheath, type SHF-2 (SHF-MUD)according to IEC 60092-359, flame retardant,halogen free and mud-resistant.

Environmental Conditions

Oil Resistancy

Test Fluid Temperature Duration

Mineral oil typeIRM 902

100°C24 Hrs

Drilling MUD resistancyThe O-Line+ cables are drilling mud resistantaccording to NEK606-2009 and IEC 60092-353

Test Fluid Temperature Test Duration

Mineral Oil typeIRM 903

100°C7 days

Water Based Mud(Calcium BromideBrine)

70°C 56 days

Oil Based Mud(CarboSea®)

170°C 56 days

Operating & installation temperatures

temperature

Max Conductor operatingtemperature

90°C

Min Environment temperature wheninstalling

-20°C

Minimum Environment temperaturewhen installed

-40°C

Low Temperature behaviorThe O-Line+ cables pass the special test for lowtemperature behaviour of CSA C22.2 and IEC60092-350: 8.9 for Cold Bend & Impact

Test temperature

Cold Bend -40°C

Cold Impact -35°C

Minimum Environment temperaturewhen installed

-40°C

Fire behaviorFlame RetardantAll O-Line+ cables provide resistance toignition and flame spread.The RFOU and BFOUcables pass the tests for flame retardancyaccording to IEC 60332-1 (vertical flame

Page 34: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Version: PN-M05J12 Subject to technical alterations Page 2 / 8This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of theinformation. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information includingincorrect translation of the information by third parties.

Offshore Cables NEK606 TS-2009

Technical Product information

propagation for a single wire or cable) and IEC60332-3-22 Cat. A (vertical flame spread ofvertically mounted bunched wires or cables). TheUX wires tested to IEC 60332-1 (vertical flamepropagation for a single wire or cable)

Halogen FreeAll O-Line+ cables are completely Halogen Free,which means that in case of fire no corrosive andtoxic halogenic gases are released which couldharm people or electronic equipment, even inlocations where the fire itself is not present. Thecable are tested for Halogen content according toIEC 60754 – 1 & IEC 60754 - 2

Low SmokeIn case of fire the O-Line+ cables have low-smokeemission, preventing people and emergency crewsgetting lost in thick smoke.Low smoke emission is tested according to IEC61034-2

Fire ResistancyAll O-Line+ Fire Resistant cables (BFOU types)enable circuit integrity in case of fire both to theold 60331-11/-21/-31 standard and the upgradedmore realistic IEC 60331-1/2 standard. Thisensures the working of emergency equipment incase of fire.

International Standards

The O-Line+ cables in this catalogue are designedand tested in accordance with the followingstandards, where applicable.

Standard Description

NEK TS606:2009

Norwegian Elektrotechnical Standard –Cables for offshore installationshalogen-free and/or mud resistantTechnical Specification

IEC 61892-4Mobile and fixed offshore units –Electrical installations - Part 4: Cables

IEC 60092-350

General construction and test methodsof power, control and instrumentationcables for shipboard and offshoreapplications

IEC 60092-351

Insulating materials for shipboardoffshore units, power, control,instrumentation, telecommunication anddata cables

IEC 60092-352Electrical installations in ships –Choiceand installation of cables for low-voltagepower systems

IEC 60092-353

Single and multicore non-radial fieldpower cables with extruded solidinsulation for rated voltages 1 kV and 3kV

IEC 60092-354

Single- and three-core power cableswith extruded solid insulation for ratedvoltages 6 kV (Um = 7.2 kV) up to 30 kV(Um = 36 kV)

IEC 60092-359Sheathing materials for shipboard powerand telecommunication cables

IEC 60092-376Cables for control and instrumentationcircuits 150/250 V (300 V)

IEC 60228 Conductors of insulated cables

IEC 60331-11

Tests for electric cables under fireconditions - circuit integrity - apparatus -fire alone at a flame temperature of atleast 750 °C

IEC 60331-21

Tests for electric cables under fireconditions - circuit integrity - proceduresand requirements - cables of ratedvoltage up to and including 0.6/1.0 kV

IEC 60331-1/2

Tests for electric cables under fireconditions – Test for method for fire withshock at temperature of at least 803° Cfor cables rated up to and including0,6/1kV

IEC 60332-1Tests on electric cables under fireconditions - part 1: test on a singlevertical insulated wire or cable

IEC 60332-3-22 - A

Tests on electric cables under fireconditions - part 3-22: test for verticalflame spread of vertically mountedbunched wires or cables - category A

IEC 60754-1

Test on gases evolved duringcombustion of electric cables -determination of the amount of halogenacid gas

IEC 60811Common test methods for insulating andsheathing materials of electric cables

IEC 61034series

Measurement of smoke density ofelectric cables burning under definedconditions

IEC 60446

Basic and safety principles for man-machine interface, marking andidentification of conductors by colours oralphanumerics

HD 308 S2:2001

European normalization (CENELEC) :Identification of cores in cables andflexible cords

Cable InstallationBending Radius

Recommended Minimum Bending Radiiaccording to IEC 60092-352

Cable TypeBendingRadius

UX <25 mm R = 4 x D

UX >25 mm R = 6 x D

RFOU, BFOU 0,6/1kV R = 6 x D

RFOU(i), RFOU( c ), BFOU (i), BFOU (c) R = 8 x D

Max. Pulling Force

Page 35: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Version: PN-M05J12 Subject to technical alterations Page 3 / 8This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of theinformation. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information includingincorrect translation of the information by third parties.

Offshore Cables NEK606 TS-2009

Technical Product information

The cable pulling tension during installation canbe estimated by means of the following formula:

Max. Pulling Force (N) = 15 × total cross section

Pulling instructionsIt is recommended to use a sleeve on the cablehead when pulling cable into cable trays, toevenly distribute the pulling stress over the wholeconductor area of the cable. When usinglubricants to lower the friction in cable pulling alubricant suitable for Halogen Free cable shouldbe used. When installing cables in below zerotemperatures, installing the cable is greatly easedwhen the cable has been stored in a location witha temperature of +15 degrees for at least 24

hours. When pulling cable in winter conditionsand the reels have been stored outside, pleasecheck the reels for ice buildup and layers of cablefrozen together, which could cause damage to thecable when unwinding the reels.

Installation temperatureMinimum recommended installation temperaturefor cables of rated voltage up to 20 kV, such as:RFOU – BFOU – RU – BU = -20°C

Page 36: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Version: PN-M05J12 Subject to technical alterations Page 4 / 8This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of theinformation. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information includingincorrect translation of the information by third parties.

Offshore Cables NEK606 TS-2009

Technical Product information

Electrical CharacteristicsElectrical values instrumentation cables

Electrical values power cables

ReactanceReactance of cables is based on the spacingbetween the conductors and of the magneticproperties of steelwork near the installed cables,and may thus vary based on the cable installation.For installations remote from steelwork the

calculated reactance can be calculated with thefollowing formula and are tabulated below:

Lf !!!"2

f = frequency in HzL = inductance in H

Type Twisting & Core size Approx Capacitance(nF/km)

Approx.Inductance,

(mH/km)

Max.conductorResistance at20°C,(Ohm/km)

L/R ratio,

(mH/Ohm)

RFOU( c ), BFOU (c) Pair 0,75mm2 100 0,67 26,3 12,7

Triple 0,75mm2 100 0,67 26,3 12,7

Pair 1,5mm2 110 0,63 12,9 24,4

Triple 1,5mm2 110 0,63 12,9 24,4

Pair 2,5mm2 125 0,59 8,02 36,8

Triple 2,5mm2 125 0,59 8,02 36,8

RFOU( i ), BFOU(i) Pair 0,75mm2 110 0,67 26,3 12,7

Triple 0,75mm2 110 0,67 26,3 12,7

Pair 1,5mm2 125 0,63 12,9 24,4

Triple 1,5mm2 125 0,63 12,9 24,4

Pair 2,5mm2 145 0,59 8,02 36,8

Triple 2,5mm2 145 0,59 8,02 36,8

Page 37: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Version: PN-M05J12 Subject to technical alterations Page 5 / 8This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of theinformation. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information includingincorrect translation of the information by third parties.

Offshore Cables NEK606 TS-2009

Technical Product information

Current Rating for General InstallationsThe current ratings are applicable for d.c. anda.c. with a nominal frequency of 50 Hz or 60 Hzand an ambient air temperature of 45° C. Forhigher frequencies, the current rating shall becalculated with an appropriate method (e.g. IEC60287). For other ambient air temperatures thecorrection factors have to be applied. Theseratings are applicable, without correction factors,for cables bunched together on cable trays, incable conduits, pipes or trunking, unless morethan six cables operating simultaneously at theirfull rated capacity are laid close together withoutfree air circulating around them. In this case acorrection factor of 0.85 should be applied. Thetables are for general reference purposes only,and do not describe all installation methodsexisting in practice. For more detailedinformation see IEC 60092-352(2005) Annex A & B.For specific situations not covered by thesestandards exact current calculations can be madeby our engineering office.

Correction Factors for ambient air temperatures!"#$%&'(%)%$*"+,)*-"#$-.%/.#&-)#.$"!$012$3$

AirTemperature

452$3 612$3 652$3 512$3 552$3 712$3$

CorrectionFactor

1.10 1.05 1.00 0.94 0.88 0.82

AirTemperature

752$3 70 C 852$3 912$3 952$3 012$3$

CorrectionFactor

0.74 0.67 0.58 0.47 - -

Current carrying capacities in continuous serviceat maximum rated conductor temperature of 90 °C in A, at 45° C ambient airtemperature

Reactance RFOU 0,6/1kV BFOU 0,6/1kV

Cross Section (mm2) 50Hz 60Hz 50Hz 60Hz

0.5 0,110 0,132 0,115 0,1382.5 0,103 0,123 0,107 0,1294 0,096 0,115 0,100 0,1206 0,090 0,108 0,094 0,11210 0,084 0,101 0,088 0,10516 0,080 0,096 0,082 0,09925 0,079 0,095 0,081 0,09835 0,076 0,092 0,078 0,09450 0,076 0,092 0,078 0,09370 0,075 0,091 0,077 0,09295 0,073 0,088 0,075 0,090120 0,072 0,086 0,073 0,088150 0,072 0,087 0,073 0,088185 0,072 0,086 0,073 0,088240 0,072 0,086 0,072 0,087300 0,071 0,086 0,072 0,086400 0,110 0,132 0,115 0,138

Page 38: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Version: PN-M05J12 Subject to technical alterations Page 6 / 8This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of theinformation. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information includingincorrect translation of the information by third parties.

Offshore Cables NEK606 TS-2009

Technical Product information

Current Rating (A)

CrossSection(mm2)

Number of cores loaded

1 2 3 & 4

1.5 23 20 16

2.5 40 26 21

4 51 34 28

6 52 44 36

10 72 61 50

16 96 82 67

25 127 108 89

35 157 133 110

50 196 167 137

70 242 206 169

95 293 249 205

120 339 288 237

150 389 331 272

185 444 377 311

240 522 444 365

300 601 511 421

d.c. a.c. d.c. a.c. d.c. a.c.

400 690 670 587 570 483 469

500 780 720 663 612 546 504

630 890 780 757 663 623 548

For cables with >4 conductors the current rating can becalculated with the following formula:

3

1

n

II #

where1I = current rating for single core, n = number

of cores

# of coresAmpacity (A)

1,5mm2 2,5mm2 4mm2

5 13 23 30

6 13 22 28

7 12 21 27

8 12 20 26

10 11 19 24

12 10 17 22

16 9 16 20

19 9 15 19

24 8 14 18

27 8 13 17

30 7 13 16

34 7 12 16

37 7 12 15

Short Circuit CurrentThe maximum permissible short circuit current for different cables is based on the formula

t

SIk !#146

Ik=the maximum permissible short-circuit current in AmpereS = the cross section area of the conductor in mm²t = the duration of the short-circuit in seconds

The formula is acceptable for an increase in temperature from 90°C at the start to 250°C at the end(according to IEC 60093-3). In the figure the permissible short-circuit current is given in kA as a function oftime (from 0.1 to 5 seconds) and as a function of the cross sectional area of the conductor.

Page 39: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Version: PN-M05J12 Subject to technical alterations Page 7 / 8This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of theinformation. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information includingincorrect translation of the information by third parties.

Offshore Cables NEK606 TS-2009

Technical Product information

Max ShortCircuitCurrent in kA

Duration ShortCircuit

Cross Section(mm2)

0,1Second

1second

1 0,461 0,146

1.5 0,692 0,219

2.5 1,154 0,365

4 1,846 0,584

6 2,77 0,876

10 4,616 1,46

16 7,387 2,336

25 11,542 3,65

35 16,159 5,11

50 23,084 7,3

70 32,318 10,22

95 43,86 13,87

120 55,403 17,52

150 69,253 21,9

185 85,413 27,01

240 110,806 35,04

300 138,507 43,8

400 184,677 58,4

500 230,846 73

630 290,866 91,98

0,1

1

10

100

1000

0,1 1 10

Short-circuit

curr

entin

kA

Duration of short-circuit in sec.

5555555555555555

Cross-sectionalare

ofconducto

rin

mm

2

500

400

300240

185150

120

95

70

50

25

16

10

6

4

2,5

1,5

Page 40: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Version: PN-M05J12 Subject to technical alterations Page 8 / 8This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of theinformation. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information includingincorrect translation of the information by third parties.

Offshore Cables NEK606 TS-2009

Technical Product information

Sheath Colours & Core Identification

Overview types, standards, core identification and sheath colour.All O-Line+ sheath and core colours are in accordance with NEK 606:2009, IEC60092-series, IEC 60446 and HD 308:S2

Application Type Core Identification Standard Sheath Colour

Low voltage (0,6/1kV) RFOU, BFOU HD308 S2-2001 black

Instrumentation (250/300V) RFOU (I), RFOU(C ), BFOU (I) BFOU(C ) Black/Blue cores + numbers grey

Different sheath colours on request

Core Identification

Low voltage power cables 0,6/1 kV -1,8/3kV – According to HD308 S2-2001

Without Yellow/Green Conductor With Yellow/Green Conductor (G)

Cond . N L1/L2 L/L2 L3 L3 PE N L1/L2 L/L2 L3

1

2

3

4

5

>5 Nr. Nr.

Notes: 1) PE = protective conductor - beschermingsleiding - Schutzleiter - conducteur de protection

N = neutral conductor - nulleiding - Neutralleiter - conducteur neutre

L, L1, L2, L3 = phase conductors - faseleidingen - Phasenleiter - conducteurs de phase

Communication Cables 250/300 V– According to NEK 606:2009

Pairs (n x 2 x y mm2)

1 2

3..etc 4..etc

Triples (n x 3 x y mm2)

1 2 3

4..etc 5..etc 6..etc

Page 41: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Marine & Offshore Green Passport

As one of the first cable manufacturers, TKF has registered with Det Norske Veritas (DNV) a declaration of conformity for a "Green Passport" for ships, in June 2009. A Green Passport is an inventory of materials present in a ship’s structure, systems and equipment that may be hazardous to health and / or the environment. The Green Passport was adopted by the IMO by resolution A.962 Clean Design / Green Passport.

A Green Passport is granted to a ship when build. On completion of the ship, a class society such as DNV issues a certificate of compliance. This, together with the inventory of hazardous materials and declarations that the ship is free of certain materials, form the Green Passport. This passport accompanies the ship throughout its working life. The final ship owner delivers the Green Passport together with the vessel to the recycling yard, so that hazardous materials in the ship can be identified and disposed of in an environmentally clean and safe way.

Yard owners and sub-suppliers must ensure that certain materials are excluded for new-build ships. Also, they must declare all materials that have been included according to various categories required by IMO.

TKF marine cables are completely free of hazardous substances and may therefore be used in a ship with a Green Passport, and do not have to be listed on the inventory of hazardous materials.

Version: 23-06-2009 Subject to technical alterations www.tkf.nl

Page 42: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

© BV Twentsche Kabelfabriek Subject to technical alterations www.tkf.nl

More information

This catalogue also contains information about product families. Information at item level can be requested via our website and from our sales staff. This catalogue has been customised. Information about products that have not been included in this catalogue is available from our sales departments and can also be found on our website www.tkf.nl.

Please contact us for additional technical or commercial information. Contact information for our sales teams can be found on the next page and on our website.

Subject to changes

TKF reserves the right to make changes to its product specifications and its range of products without informing its clients of this in advance.

Disclaimer

This catalogue is put together with great care. Nevertheless we can’t give any guarantees regarding the completeness, correctness or actualization of the information in this catalogue.No rights can be derived from the information as shown in this catalogue.TKF is entitled to modify this catalogue at all times with immediate effect due to (for example) changes in legislation.

TKF can’t be held responsible for the content of this catalogue or the consequences of using the information including incorrect translation of the information by third parties.

© TKF

All rights reserved. Information in this catalogue may only be distributed with acknowledgement of the source.

Terms of delivery

Our general terms of delivery apply to all our deliveries including the products named in the catalogue. They are available via our website www.tkf.nl or from our sales departments.

Prices

Please contact our sales department for price information. The gross item prices of part of our portfolio have been included in our TPL price list.It can be downloaded via our website or requestedfrom our sales staff.

Page 43: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

Global customer service

Please consult the table below for the contact information for our sales teams. The latest information

about our distributors worldwide is available from our sales staff and on our website (www.tkf.nl).

Cable drum sizes and weights

A wide range of drums with various sizes and weights is used to store and transport our cables.

The most common types of drum and their sizes and weights are shown in this table.

Empty drum return

To get your empty drums in the Netherlands collected quickly, please send your

request to our shipping department via the website (www.tkf.nl) or by e-mail to

[email protected]. If drums have to be collected outside the Netherlands, please

contact our sales staff.

Broadband

Tel. +31 (0)53 573 23 89 Fax +31 (0)53 573 23 06 [email protected]

Energy

Tel. +31 (0)53 573 23 86 Fax +31 (0)53 573 21 84 [email protected]

Marine & Offshore

Tel. +31 (0)53 573 23 90 Fax +31 (0)53 573 21 84 [email protected]

Installation

Tel. +31 (0)53 573 23 88 Fax +31 (0)53 573 21 84 [email protected]

Industry

Tel. +31 (0)53 573 23 90 Fax +31 (0)53 573 21 84 [email protected]

Infra

Tel. +31(0)53 573 23 187 Fax +31 (0)53 573 21 84 [email protected]

General & Sales Support

Tel. +31 (0)53 573 22 55 Fax +31 (0)53 573 23 61 [email protected]

Flange

diameter (F)

mm

Core

diameter (K)

mm

Central hole

diameter (A)

mm

Largest

width (B)

mm

Winding

width (W)

mm

Empty

weight

kg

Volume

m3

F = Diameter flange

K = Diameter core

A = Diameter axle-hole

B = Largest width

W = Winding width

W

B

A K F

© BV Twentsche Kabelfabriek Subject to technical alterations www.tkf.nl-

*600 250 80 468 400 7,5 0,17

*800 400 100 480 400 14 0,31

800 500 100 500 485 43 0,31

*1000 500 100 605 485 28 0,31

1000 500 100 609 485 74 0,61

1200 600 100 724 600 108 1,04

1500 800 100 946 750 160 2,13

1600 800 100 1030 834 240 2,64

1800 900 100 1030 834 400 3,34

2100 900 100 1148 950 450 5,06

2250 1400 100 1122 830 600 5,68

2500 1450 100 1220 930 700 7,63

2500 1450 100 1458 1150 800 9,11

2650 1450 100 1488 1175 850 10,45

2800 1700 100 1520 1157 1050 11,92

3000 1600 100 1600 1235 1150 14,40

* Plastic drum

Page 44: TKF offshore catalogue 131122 EN · Halogen Free & MUD-resistant low voltage cables for fixed installation on offshore topsides, in safe & EX-areas. For power, control and lighting

BV Twentsche Kabelfabriek

Spinnerstraat 15

P.O. Box 6

7480 AA Haaksbergen

The Netherlands

Tel.: +31 (0)53 573 22 55

Fax: +31 (0)53 573 21 85

E-mail: [email protected]

Website: www.tkf.nl

Choose TKF - Choose quality!