16 www.ssac.com • 800-843-8848 • fax: 605-348-5685
TRDU SeriesTimer
Available Models:
Time DelayType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MicrocontrollerRange: Switch Selectable** . . . . . . . . . . . . . Single Functions: 0.1s - 1,705h in 8 ranges Dual Functions: 0.1s - 3,100m each in 8 rangesAdjustments . . . . . . . . . . . . . . . . . . . . . . . . . . Multiplier: 3 position DIP switches select 0.1, 1, 10, or 100 in s or mSetting Accuracy . . . . . . . . . . . . . . . . . . . . . . ±1% or 50ms, whichever is greaterRepeat Accuracy . . . . . . . . . . . . . . . . . . . . . . ±0.1% or 20ms, whichever is greaterTiming Functions . . . . . . . . . . . . . . . . . . . . . . Five switches are provided to set one of twenty-one single or dual functionsReset Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 50msInitiate Time . . . . . . . . . . . . . . . . . . . . . . . . . . 120VAC: 75msTime Delay vs Temp. & Voltage . . . . . . . . . ±1%IndicationTwo LEDs indicate . . . . . . . . . . . . . . . . . . . . 1) Input voltage applied 2) Output relay statusInputVoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12VDC, 24VAC/DC, 120VAC, or 230VACTolerance 12VDC & 24VAC/DC . . . . . . . . -15% - 20% 120 & 230VAC . . . . . . . -20% - 10%AC Line Frequency . . . . . . . . . . . . . . . . . . . . 50/60HzPower Consumption . . . . . . . . . . . . . . . . . . . 24 to 230V ≤ 3W; 12VDC ≤ 2W
OutputType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electromechanical relayForm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPDT or DPDTRating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10A resistive @ 120/240VAC & 28 VDC; 1/3 hp @ 120/240VACLife . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical – 1 x 107; Electrical – 1 x 106
ProtectionIsolation Voltage . . . . . . . . . . . . . . . . . . . . . . ≥ 1500V RMS input to outputInsulation Resistance . . . . . . . . . . . . . . . . . . . ≥ 100 MΩ Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC units are reverse polarity protectedMechanicalMounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . Plug-in socketDimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 x 2.39 x 1.78 in. (78.7 x 60.7 x 45.2 mm)Termination . . . . . . . . . . . . . . . . . . . . . . . . . . Octal 8-pin plug-in or magnal 11-pin plug-inEnvironmentalOperating / Storage Temperature . . . . . . . -20° to 65°C / -40° to 85°CWeight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 5.8 oz (164 g)
**For CE approved applications, power must be removed from the unit when a switch position is changed.
Specifications
Order Table:
Connection:
The TRDU Series is a versatile universal time delay relay with 21 selectable single and dual functions. The dual functions replace up to three timers required to accomplish the same function. Both the function and the timing range are selectable with switches located on the face of the unit. Two LED’s indicate input voltage and output status. This device offers full 10A isolated relay output contacts in either SPDT or DPDT. The TRDU replaces hundreds of part numbers, thereby, reducing your stock inventory requirements.
Features:
• Microcontroller ±0.1% repeat accuracy• Multifunction – 21 timing functions• Multirange – 0.1s - 1,705h in 8 ranges• Switch selectable modes, time delay, &
ranges• AC & DC input voltages are available• Isolated, 10A, SPDT or DPDToutput contactsApprovals:
Auxiliary Products:
•Panel mount kit: P/N: BZ1 •Hold-down clips (sold in pairs):
P/N: PSC8 (NDS-8) P/N: PSC11 (NDS-11)
•11-pin socket: P/N: NDS-11•Octal 8-pin socket: P/N: NDS-8 •DIN rail:
P/N: C103PM (Al)
TRDU120A1TRDU120A2TRDU120A3TRDU12D1TRDU12D3
TRDU230A2TRDU24A1TRDU24A2TRDU24A3
L1 N/L2
L1 N/L2
L1 N/L2V = Voltage S1 = Initiate Switch
*Limited to 9 operating functions in 8-pin DPDT units
Five switches are provided to set one of 10 single or 11 dual modes of operation.Single Functions- * Delay-on-Make Delay-on-Break * Recycle (ON time first, equal recycle delays) Single Shot * Interval Trailing Edge Single Shot Inverted Single Shot Inverted Delay-on-Break Accumulative Delay-on-Make Retriggerable Single Shot (motion detector)Dual Functions - Delay-on-Make/Delay-on-Break * Delay-on-Make/Recycle (ON time first, equal recycle delays) * Delay-on-Make/Interval Delay-on-Make/Single Shot * Interval/Recycle (ON time first, equal recycle delays) Delay-on-Break/Recycle (ON time first, equal recycle delays) Single Shot/Recycle (ON time first, equal recycle delays) * Recycle - both times adjust. (ON time first) * Recycle - both times adjust. (OFF time first) * Interval/Delay-on-Make Accumulative Delay-on-Make/Interval
21 Functions:
8-pin DPDT
8-pin SPDT
11-pin DPDT
TRDU X Input Voltage12D - 12VDC24A - 24VAC/DC 120A - 120VAC230A - 230VAC
X Base Connection1 - 8-pin DPDT*2 - 8-pin SPDT3 - 11-pin DPDT
For more information see:Appendix A, page 163-164 for function diagrams.Appendix B, page 165, Figure 5 for dimensional drawing.
If desired part number is not listed, please call us to see if it is technically possible to build .
163www.ssac.com • 800-843-8848 • fax: 605-348-5685
Appendix A - Timer Functions
Continued on next page...
TRDU Function Diagrams
ON
A B C D E
B
ON
A B C D E
BRE
ON
A B C D E
RXE
ON
A B C D E
ION
A B C D E
IRE
ON
A B C D E
MON
A B C D E
MB
ON
A B C D E
MI
ON
A B C D E
MRE
A B C D E
ONMS
ON
A B C D E
RE
ON
A B C D E
SRE
ON
A B C D E
TS
ON
A B C D E
UB
ON
A B C D E
US
A B C D E
ONS
Dual FunctionsSingle Functions
* Delay-on-Make
Delay-on-Break
* Recycle(ON Time First, Equal Delays)
Single Shot
* Interval
Trailing Edge Single Shot
InvertedSingle Shot
InvertedDelay-on-Break
* Recycle (ON Time First) Both Times Adjustable
Single ShotRecycle (ON Time First)
Delay-on-BreakRecycle (ON Time First)
Delay-on-MakeDelay-on-Break
* Delay-on-Make Recycle (ON Time First)
* Delay-on-Make Interval
Delay-on-MakeSingle Shot
* Interval Recycle (ON Time First)
* 9 Functions included in the 8 pin DPDT models
164 www.ssac.com • 800-843-8848 • fax: 605-348-5685
Appendix A - Timer/Flasher Functions
Flasher (NC)
V = Voltage S1 = Initiate Switch L = LoadR = Reset T1 = ON Time T2 = OFF Time
T1 ≅ T2
Flasher (OFF First)
V = Voltage R = Reset L = LoadT1 = ON Time T2 = OFF Time
T1 ≅ T2
Flasher (ON First)
V = Voltage R = Reset L = LoadT1 = ON Time T2 = OFF Time T1 ≅ T2
ON time plus OFF time equals one complete flash.
Flasher (Alternating)
V = Voltage L1 = Load 1 L2 = Load 2R = Reset T1 = ON Time T2 = OFF Time
T1 ≅ T2
V = Voltage R = Reset T1 = ON Time T2 = OFF Time
NO = Normally Open NC = Normally Closed
V = Voltage R = Reset L (1...4) = Lamps TD = Time Delay (all are equal)
SC4 shown; SC3, L4 is eliminated and L1 TD begins as soon as L3 TD is completed .
Flasher (Chasing)Flasher (ON First-DPDT)
Flashers & Aux. Modules
V = Voltage L = Load T1 = ON TimeT2 = OFF Time R = Reset
T1 ≅ T2
Flasher Function Diagrams
ON
A B C D E
AM
ON
A B C D E
AMI
ON
A B C D E
RXD
ON
A B C D E
IM
A B C D E
ONPS
Dual FunctionsSingle Functions
RetriggerableSingle Shot
AccumulativeDelay-on-Make
Accumulative Delay-on-MakeInterval
* Interval Delay-on-Make
* Recycle (OFF Time First) Both Times Adjustable
* 9 Functions included in the 8 pin DPDT models
5 Switches for Function Selection3 Switches for Time Delay Range
KEY V=Voltage, R=Reset, S1=Initiate Switch, NO=Normally Open Contact, NC=Normally Closed Contact, TD,TD1,TD2=Complete Time Delay, t=Partial Time Delay, DOM=Delay-on-Make, DOB=Delay-on-Break, REC=Recycle, SS=Single Shot, INT=Interval, M=Minutes, S=Seconds, = Undefined time
NOTE: The time delay range is the same forboth functions when dual functions are selected.
165www.ssac.com • 800-843-8848 • fax: 605-348-5685
HSPZ
TRDUTRU
ASQU; ASTU; DSQU; DSTU
(snap for mounting
bases)
ERD3; ERDI; ERDM ORB; ORM; ORS
CT; ESD5; ESDR; FS100; FS200; FS300; KRD3; KRD9; KRDB; KRDI; KRDM; KRDR; KRDS; KRPD; KRPS; KSD1; KSD2; KSD3; KSD4; KSDB; KSDR; KSDS; KSDU; KSPD; KSPS; KSPU; KVM; T2D; TA; TAC1; TAC4; TDU; TDUB; TDUI; TDUS; TL; TMV8000; TS1; TS2; TS4; TS6; TSB; TSD1; TSD2; TSD3; TSD4; TSD6; TSD7; TSDB; TSDR; TSDS; TSS; TSU2000
HLV; HRD3; HRD9; HRDB; HRDI; HRDM; HRDR; HRDS; HRID; HRIS; HRIU; HRPD; HRPS; HRPU; HRV; RS
FA; FS; FSU1000*; NHPD; NHPS; NHPU; NLF1*; NLF2*; PHS*; PTHF*; SIR1; SIR2; SLR1*; SLR2*; TH1; TH2; THC; THD1; THD2; THD3; THD4; THD7; THDB; THDM; THDS; THS
PLM; PLR; TDB; TDBH; TDBL; TDI; TDIH; TDIL; TDM; TDMB; TDMH; TDML; TDR; TDS; TDSH; TDSL
FS500; PRLB; PRLM; PRLS; TRB; TRM; TRS
Appendix B - Dimensional Drawings
FS100; FS400
FIGURE 1 FIGURE 2 FIGURE 3
FIGURE 4 FIGURE 5 FIGURE 6
FIGURE 7
FIGURE 10
FIGURE 8 FIGURE 9
FIGURE 11 FIGURE 12
inches (millimeters)
*If unit is rated @ 1A, see Figure 1