Tim Fenn RIMA International Conference invited presentation 2014

18
Welcome to the 2014 International Reflective Insulation Manufacturers Conference

Transcript of Tim Fenn RIMA International Conference invited presentation 2014

Welcome to the 2014

International Reflective Insulation Manufacturers Conference

Mind the Gap: Design versus

“As Built” Performance

Tim Fenn

I-RIM Conference 2014

Predicted Annual Energy Costs 100m2 House UK 2013

I-RIM Conference 2014

Annual Predicted Energy Cost: Gas & Electric

Victorian House

1990's House Passivhaus

Electricity £600 £600 £463Lighting £104 £104 £10Hot Water £340 £340 £170Heating £1,000 £520 £60

Total £2,045 £1,565 £703

Annual Heating Demand

I-RIM Conference 2014

Victorian House 250KWh/m2/yr 1990's House 130KWh/m2/yr Passivhaus 15KWh/m2/yr

Gas 0.04 1000 520 60

Oil 0.05 1250 650 75

Electric 0.15 3750 1950 225

£250

£750

£1,250

£1,750

£2,250

£2,750

£3,250

£3,750

Annual Heating Cost (100m² house)

Annual

Cost

£

Annual Hot Water Demand

I-RIM Conference 2014

Cost\KWh £ Victorian House 8500 KWh/yr Annual £

Low Energy House 4250 KWh/yr Annual £

Hot Water Gas 0.04 340 170

Hot Water Oil 0.05 425 212.5

Hot Water Electricity 0.15 1275 637.5

£100

£300

£500

£700

£900

£1,100

£1,300

Annual Hot Water Demand and Cost

Annual

cost

£

Variation in Performance: Germany

I-RIM Conference 2014

Target Killers:

I-RIM Conference 2014

• What can you achieve with what building?

• How much do you want/can afford to spend? & remember 1st 50% easy.

• What planners/conservation officers will allow?

• What your neighbours will allow or not do?

• Site constraints?

Target Killer: Building Envelop

I-RIM Conference 2014

• Insulation installation The GAP!

• Piercing vapour barrier

• Insulating pipework & thermal stores

• Pipework runs

• Incorrect materials

Target Killer: Materials

I-RIM Conference 2014

• Wet insulation will not perform!

• Deterioration in insulation performance over time?

• Durability of tapes?

• Wet building may take time to perform to its design spec?

Software Limitations

I-RIM Conference 2014

In both SAP & PHPP• Sunspaces ignored

• Radiant barriers ignored

• Thermal mass?

• Air leakage?

SAP VS PHPP

I-RIM Conference 2014

November December January February0

1000

2000

3000

4000

5000

6000Total Energy Consumption at Bakers Shaw

PHPP

Actual

SAPkWh

Hemcrete/Airflex Test Building

I-RIM Conference 2014

Hemcrete/Airflex Test Building

I-RIM Conference 2014

Wall Section and U Value

I-RIM Conference 2014

Wall Temperature Gradient

I-RIM Conference 2014

0

5

10

15

20

25

InsideFoil FrontFoil BackHempGreen WallOutside

3rd Feb 11th Feb

February Average Temperatures Benson

Conclusions

I-RIM Conference 2014

• Vapour barrier\reflective foil (if installed correctly!) adds significant improvement to building envelop performance better than predicted via software

• Vapour barrier/reflective foil leads to highest levels of air-tightness in otherwise leaky buildings

• UK needs more in situ research to understand gaps in performance

Questions?

I-RIM Conference 2014

Thank you!

800/279-4123www.rimainternational.org