TI service item description - nak-mci.ir

49
TI service item description Page 1 TI service item description

Transcript of TI service item description - nak-mci.ir

Page 1: TI service item description - nak-mci.ir

TI service item description Page 1

TI service item description

Page 2: TI service item description - nak-mci.ir

TI service item description Page 2

Contents 1. General ............................................................................................................................................. 5

2. TIS0001.01 C antenna line ............................................................................................................... 5

3. TIS0002.01 C TRS line ....................................................................................................................... 6

4. TIS0003.01 CIntg General TRS Node ................................................................................................ 7

5. TIS0004.01 Extra work(Site clean up, site folder etc) ...................................................................... 7

6. TIS0005.01 File based CIntg BS ........................................................................................................ 7

7. TIS0006.01 I 1 5-8 antenna line add ................................................................................................ 8

8. TIS0007.01 I 1 5-8 antenna line basic .............................................................................................. 8

9. TIS0008.01 I 1-2 antenna line add ................................................................................................... 9

10. TIS0009.01 I 1-2 antenna line basic ................................................................................................. 9

11. TIS0010.01 I 7-8 antenna line add ................................................................................................. 10

12. TIS0011.01 I 7-8 antenna line basic ............................................................................................... 10

13. TIS0012.01 I coupler/Di/Triplexer .................................................................................................. 11

14. TIS0013.01 I DDF basic ................................................................................................................... 11

15. TIS0014.01 I dish up to 120 cm ...................................................................................................... 12

16. TIS0015.01 I dish up to 60 cm ........................................................................................................ 12

17. TIS0016.01 I BS plinth .................................................................................................................... 13

18. TIS0017.01 I BS system module ..................................................................................................... 13

19. TIS0018.01 I BS sector modules .................................................................................................... 14

20. TIS0019.01 I floor mount 19-23 cab .............................................................................................. 15

21. TIS0020.01 I floor mount 19-23 open frame ................................................................................. 16

22. TIS0022.01 I outdoor BS cab ......................................................................................................... 16

23. TIS0023.01 I panel antenna up to 2.5m ......................................................................................... 17

24. TIS0024.01 IC cable 75/120 ohm basic .......................................................................................... 17

25. TIS0025.01 IC cable IDU-ODU basic ............................................................................................... 18

26. TIS0026.01 IC FO cable basic.......................................................................................................... 18

27. TIS0027.01 IC LAN cable basic ....................................................................................................... 19

28. TIS0028.01 IC macro outdoor power basic .................................................................................... 19

29. TIS0029.01 IC MW HSB or dual pol kit ........................................................................................... 20

30. TIS0030.01 IC MW ODU ................................................................................................................. 21

31. TIS0031.01 IC ODU and dish up to 120cm ..................................................................................... 22

Page 3: TI service item description - nak-mci.ir

TI service item description Page 3

32. TIS0032.01 IC ODU and dish up to 60cm ....................................................................................... 22

33. TIS0033.01 IC PCM x-connection 75ohm ....................................................................................... 23

34. TIS0034.01 IC PDF .......................................................................................................................... 24

35. TIS0035.01 IC RG-214 Flexbus or IFL run basic .............................................................................. 24

36. TIS0036.01 IC RG-223 Flexbus run basic ........................................................................................ 25

37. TIS0037.01 IC SDH MW indoor unit ............................................................................................... 25

38. TIS0038.01 IC TRS indoor unit ........................................................................................................ 26

39. TIS0039.01 Implementation supervising BS-CT ............................................................................. 27

40. TIS0040.01 Installation planning BS-CT ......................................................................................... 28

41. TIS0041.01 Rem Flexbus per 10m .................................................................................................. 29

42. TIS0042.01 Rem MW ODU ............................................................................................................. 30

43. TIS0043.01 Rem ODU and dish up to 120cm ................................................................................. 30

44. TIS0044.01 Rem ODU and dish up to 60cm ................................................................................... 31

45. TIS0045.01 Rem TRS indoor unit ................................................................................................... 32

46. TIS0046.01 Site survey BS site ....................................................................................................... 33

47. TIS0047.01 Site survey TRS ............................................................................................................ 33

48. TIS0048.01 Transport DOP/Site to Site 0-3,5t regulr ..................................................................... 34

49. TIS0049.01 Travel ........................................................................................................................... 35

50. TIS0050.01 Travel add (Extra site visit) .......................................................................................... 35

51. TIS0051.01 Travel TRS .................................................................................................................... 36

52. TIS0052.01 I BS RF modules ........................................................................................................... 36

53. TIS0053.01 Rem macro BS or power cabinet................................................................................. 37

54. TIS0054.01 IC Micro BS Power module .......................................................................................... 38

55. TIS0055.01 Rem panel antenna up to 2.5m .................................................................................. 38

56. TIS0056.01 Rem 1-2 antenna line add ........................................................................................... 39

57. TIS0057.01 Rem 7-8 antenna line add ........................................................................................... 39

58. TIS0058.01 Swap documentation .................................................................................................. 40

59. TIS0059.01 Rem micro BS equipment............................................................................................ 40

60. TIS0060.01 Site Audit & Documentation ....................................................................................... 40

61. TIS0063.01 Fusion and OTDR test .................................................................................................. 41

62. TIS0065.01 Repeater Telecom implementation ............................................................................ 41

63. TIS0066.01 High Power Repeater acceptance and documentation .............................................. 41

Page 4: TI service item description - nak-mci.ir

TI service item description Page 4

64. TIS0066.02 Low Power Repeater acceptance and documentation ............................................... 42

65. TIS0067.01 IBS DAS installation per antenna.................................... Error! Bookmark not defined.

66. TIS0068.01 DAS installation (feeder or fiber) per 10m .................................................................. 42

67. TIS0069.01 Conduit and Duct installation ........................................ Error! Bookmark not defined.

68. TIS0070.01 RRU or RU installation .................................................... Error! Bookmark not defined.

69. TIS0071.01 I BS Remote RF modules ............................................................................................. 42

70. TIS0071.02 I Optical fiber up to 100 m .......................................................................................... 43

71. TIS0072.01 Test Call ....................................................................................................................... 44

72. TIS0071.07 S General Fiber Optic Installation & Commissioning .................................................. 44

73. TIS0064.07 IC General Indoor Antenna System (SISO) .................................................................. 44

74. TIS0064.09 IC General Indoor Antenna System (MIMO) ............................................................... 45

75. TIS0062.05 Subway DAS Installation per antenna (SISO) .............................................................. 46

76. TIS0062.06 Subway DAS Installation per antenna (MIMO) ........................................................... 47

77. TIS0062.03 Tunnel DAS Installation per Antenna (SISO) ............................................................... 47

78. TIS0062.07 Tunnel DAS Installation per antenna (MIMO) ............................................................. 48

79. TIS0055.02 Rem IBS Antenna ......................................................................................................... 49

Page 5: TI service item description - nak-mci.ir

TI service item description Page 5

General

Includes

These activities are included for every service item: - Unpacking the delivery - Inventory checking of the delivery and discrepancy reporting - Preparation of documentation for the work performed under the specific service item as part of the site folder or link folder - Waste disposal including transportation, recycling of the waste according to our environmental requirements and cleaning of the site in relation to and in the scope of the works performed under the specific Service Item.

Excludes

These activities are excluded from the service item, if not indicated in the includes

section of that specific service item

TIS0001.01 C antenna line

Commissioning of antenna line

Service

Commissioning of the antenna line in its complete length including antenna measurements. Project specific processes and work instructions with limitations and thresholds to be reached are applicable and will be defined accordingly. The interface for the measurements (top of BTS or internal jumpers) will be defined from the project. As standard measurements can be counted tests such as Return Loss, Cable Loss, Antenna Isolation Test and Distance to Fault. The measurement equipment such as Site Master has to be calibrated and must fulfill the specifications given from the project.

Excludes

Installation of antenna. Installation of antenna line Installation of active and passive antenna line components, such as Bias Tee, MHA, diplexer, triplexer, combiner, etc.

Testing of any other equipment than feeder line and antenna.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 C Antenna Line 100% 1 pcs

2 Return Loss Measurement 100% 1 pcs Processes, work instruction and measurement limits according the project are applicable

3 Cable Loss Measurement 100% 1 pcs Processes, work instruction and measurement limits according the project are applicable

Page 6: TI service item description - nak-mci.ir

TI service item description Page 6

4 Isolation Test Measurement 100% 1 pcs Processes, work instruction and measurement limits according the project are applicable

5 Distance To Fault Measurement 100% 1 pcs Processes, work instruction and measurement limits according the project are applicable

6 Documentation 100% 1 pcs

TIS0002.01 C TRS line

Commissioning of transmission line

Service

Commissioning of a transmission line, which may include the following Installation of test equipment and data cables that are needed to perform the commissioning. Installation of physical loop at the other end of the link. Remote loop activation for the other end of the link. Performance of BER test between two sites (covering one or more TRS links). Performance of T1, E1 or other leased line testing between two sites (covering one or more TRS links). Run test according to test procedure using the provided bit sample. Analysis of test results. Complete any test reports related to the test results (if required).

Material

Excludes

Special cases and other requirements

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 Supply and 100% 1 pcs

installation of test equipment and data cables

2 Installation of 100% 1 pcs Remote loop activation physical loop

3 Performance of 100% 1 pcs

BER test between two

sites

4 Analysis of test 100% 1 pcs Complete any test reports results related to the test results

Page 7: TI service item description - nak-mci.ir

TI service item description Page 7

TIS0003.01 CIntg General TRS Node

Commissioning and Integration of General TRS Node Equipment

Service

Fastening of plug-in units in their positions. Commissioning of transmission node equipment in its installed configuration. Integration of the transmission node basic configuration up to the maximum capacity. Creation of the transmission node in Network Management System.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Commissioning of General TRS 100% 1 pcs Commissioning of basic

Node transmission node 2 Integration of General TRS Node 100% 1 pcs Integration of basic

transmission node 3 NE Creation in NMS 100% 1 pcs

TIS0004.01 Extra work (Site cleanup, site folder etc.)

Extra work, Site cleanup, compilation of site folder etc.

Service

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Extra work 100% 1 pcs

2 Site clean up 100% 1 pcs

3 Completion of site folder 100% 1 pcs

TIS0005.01 File based CIntg BS

File based commissioning and integration of base station

Service

Creation of the HW configuration (On-site) Define site ID (On-site) Activate needed line interfaces (On-site) Defining O&M channel in A-bis X-connection table (On-site) Perform test calls (on site) if applicable

Excludes

Manual creation of A-bis X-connections Manual creation of time slot allocation.

Page 8: TI service item description - nak-mci.ir

TI service item description Page 8

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Set up specified integration 100% 1 pcs According to project

parameters specifications 2 BS Testing 100% 1 pcs According to project

specifications 3 Documentation 100% 1 pcs According to project

specifications 4 Test calls (on site) 0% 1 pcs If applicable

TIS0006.01 I 1 5-8 antenna line add

Installation of maximum extra 10m of 1 5/8" antenna line.

Service

Installation of additional meters of 1 5/8" feeder cable with fixing accessories (clamps, cable ties), grounding kits and waterproofing materials.

Excludes

Installation of additional length of a different RF feeder cable than 1 5/8". Installation of the basic length of the RF feeder including connectors and their waterproofing. Installation of jumper cables. Installation of RF feeder labels. Testing of the complete RF feeder run.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Feeder Cable Installation 100% 10 m Incl fixing

TIS0007.01 I 1 5-8 antenna line basic

Installation of a 1 5/8" antenna line basic length

Service

Dismantling and reassembly of the cable entry or gland. Installation of 1 5/8" feeder cable in the defined length with fixing accessories (clamps, cable ties), grounding kits and waterproofing materials, labels and connectors. Installation of jumper cables with fixing accessories, waterproofing materials and labels,. Termination of the antenna line to the Base Station. Termination of the antenna line to the antenna including waterproofing of the outdoor connector (if antenna exists).

Excludes

Installation of antenna. Installation of active and passive antenna line components, such as Bias Tee, MHA, diplexer, triplexer, combiner, etc. Installation of cable support structures. Installation of additional 1 5/8" feeder cable. Installation of any

Page 9: TI service item description - nak-mci.ir

TI service item description Page 9

other type of RF feeder cable. Commissioning of antenna line and antenna

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Feeder Cable Installation 100% 40 m Incl. Grounding and waterproof. 2 Jumper Installation 100% 1 lot Incl. Sealing

TIS0008.01 I 1-2 antenna line add

Installation of maximum extra 10m of 1/2" antenna line.

Service

Installation of additional meters of 1/2" feeder cable with fixing accessories (clamps, cable ties), grounding kits and waterproofing materials.

Excludes

Installation of additional length of a different RF feeder cable than 1/2". Installation of the basic length of the RF feeder including connectors and their waterproofing. Installation of jumper cables. Installation of RF feeder labels. Testing of the complete RF feeder run.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Feeder Cable Installation 100% 10 m Incl. fixing

TIS0009.01 I 1-2 antenna line basic

Installation of a 1/2" antenna line basic length

Service

Dismantling and reassembly of the cable entry or gland. Installation of 1/2" feeder cable in the defined length with fixing accessories (clamps, cable ties), grounding kits and waterproofing materials, labels and connectors. Installation of jumper cables with fixing accessories, waterproofing materials and labels. Termination of the antenna line to the Base Station. Termination of the antenna line to the antenna including waterproofing of the outdoor connector (if antenna exists).

Excludes

Installation of antenna. Installation of active and passive antenna line components, such as Bias Tee, MHA, diplexer, triplexer, combiner, etc. Installation of cable support structures. Installation of additional 1/2" feeder cable. Installation of any other type of RF feeder cable. Commissioning of antenna line and antenna

Page 10: TI service item description - nak-mci.ir

TI service item description Page 10

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Feeder Cable Installation 100% 20 m Incl. Grounding and waterproof. 2 Jumper Installation 0% 1 lot Incl. Sealing

TIS0010.01 I 7-8 antenna line add

Installation of maximum extra 10m of 7/8" antenna line.

Service

Installation of additional meters of 7/8" feeder cable with fixing accessories (clamps, cable ties), grounding kits and waterproofing materials.

Excludes

Installation of additional length of a different RF feeder cable than 7/8". Installation of the basic length of the RF feeder including connectors and their waterproofing. Installation of jumper cables. Installation of RF feeder labels. Testing of the complete RF feeder run.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Feeder Cable Installation 100% 10 m DNxxx Incl fixing

TIS0011.01 I 7-8 antenna line basic

Installation of a 7/8" antenna line basic length

Service

Dismantling and reassembly of the cable entry or gland. Installation of 1 run 7/8" feeder cable in the defined length with fixing accessories (clamps, cable ties), grounding kits and waterproofing materials, labels and connectors. Installation of jumper cables with fixing accessories, waterproofing materials and labels, Termination of the antenna line to the Base Station. Termination of the antenna line to the antenna including waterproofing of the outdoor connector (if antenna exists).

Excludes

Installation of antenna. Installation of active and passive antenna line components, such as Bias Tee, MHA, diplexer, triplexer, combiner, etc.

Page 11: TI service item description - nak-mci.ir

TI service item description Page 11

Installation of cable support structures. Installation of additional 7/8" feeder cable. Installation of any other type of RF feeder cable. Commissioning of antenna line and antenna

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Feeder Cable Installation 100% 30 m Incl. Grounding and waterproof. 2 Jumper Installation 100% 1 lot Incl. Sealing

TIS0012.01 I coupler/Di/Triplexer

Installation of coupler/Di/Triplexer, on the antenna line (down and top)

Service

Installation of one coupler/Di/Triplexer with additional fixing material including connection to the antenna line (only if RF feeder exists) with installation of waterproofing. Installation of additional jumpers with fixing materials, and labels including installation of waterproofing. Installation of label for the coupler.

Excludes

Commissioning of antenna line and antenna Installation of more than two coupler. Installation of antenna line including other active and passive components.

Special cases and other requirements

If the antenna line is installed in the same time as the coupler, the supply and installation of waterproofing for the RF feeder-coupler connector as well as termination of the RF feeder to the coupler are part of the antenna line installation.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Installation of jumper 100% 2 lot Incl. labeling 2 Installation of Coupler 100% 2 pcs Inc. fixing & labeling

TIS0013.01 I DDF basic

Installation of DDF, basic configuration type

Service

Installation of a DDF system basic configurations including mounting materials. Installation

Page 12: TI service item description - nak-mci.ir

TI service item description Page 12

of DC power cable with fixing accessories, labels and connectors (cable shoes) in the defined length. Installation of labels for the DDF and DC breakers.

Material

Excludes

Installation of other DDF configurations.

Special cases and other requirements

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark

1 DDF Installation 100% 1 pcs DNxxx For basic config.

2 DC Power Cable Installation 100% 3 m DNxxx Incl. labeling & testing

TIS0014.01 I dish up to 120 cm

Installation of dish up to 120 cm.

Service

Assembling of microwave dish in all its parts. Installation of microwave dish up to 120 cm in diameter with labels and fixing accessories. Installation of dish side strut (if applicable).

Excludes

Installation of the dish pole and bracket. Installation of feeder line.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark

1 Dish installation 100% 1 pcs DNxxx Incl. fixing accessories and labeling and rough alignment.

TIS0015.01 I dish up to 60 cm

Installation of dish up to 60 cm.

Service

Installation of microwave dish up to 60 cm in diameter with labels and fixing accessories.

Excludes

Installation of the dish pole and bracket.

Page 13: TI service item description - nak-mci.ir

TI service item description Page 13

Installation of feeder line.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark

1 Dish installation 100% 1 pcs DNxxx Incl. fixing accessories and labeling and rough alignment.

TIS0016.01 I BS plinth

Installation of base station plinth

Service

Installation and fixing of base station plinth on floor, wall or pole/mast. Installation of grounding cable for the base station plinth with fixing accessories (cable ties), labels and connectors (lugs) up to the defined length including testing of the complete cable run.

Excludes

Installation of more than one base station plinth. Installation of 19" rack, indoor or outdoor cabinet. Transportation of the equipment to the site.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Installation of BS plinth 100% 1 pcs Incl. fixing or pole mounting 2 Installation of Grounding Cable 100% 3 m Incl. labeling & testing

TIS0017.01 I BS system module

Installation and installation testing of Flexi base station system module

Service

Installation of integrated transmission plug-in unit (base station system module). Installation of base station system module including casing, fixing of earthquake protection screws, front and back covers if applicable. Installation of grounding cable between base station system module and base station plinth with fixing accessories (cable ties) including testing of the complete cable run. Installation of DC power cable with fixing accessories (cable ties), labels and connectors (shoes) up to the defined length if applicable including testing of the complete cable runs. Installation of alarm cable with fixing accessories (cable ties), labels and connectors up to the defined length including testing of the complete cable run. Installation of labels for DC breakers, AIB and ADM. Terminating of FlexBus cable, fiber optic or PCM cables to the integrated transmission plug-in unit (only for existing cables). Installation testing of the Base Station system unit and integrated transmission plug-in unit.

Excludes

Page 14: TI service item description - nak-mci.ir

TI service item description Page 14

Installation of more than one base station system module. Installation and Commissioning of an external DC Power Supply System. Installation of any other integrated transmission plug-in unit not defined in customer contract. Supply, installation and testing of transmission connections and links. Testing of external alarms from AIB or ADB up to alarm generating sensors. Installation and commissioning of transmission indoor unit (other than integrated). Transportation of the equipment to the site.

Special cases and other requirements

Cross-connecting of external alarms in Alarm Distribution Module is not included in this Service item, because it is assumed that the incoming alarms and the alarm cable share the same ADM.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Installation of BS system 100% 1 pcs Incl. fixing, casing, front and

module back covers 2 Installation of Int. TRS PIU 100% 1 pcs Incl label, TRM vable

termination term. 3 Installation of Grounding Cable 100% 2 m Incl. testing 4 Installation of DC Power Cable 100% 10 m Incl. labeling & testing 5 Installation of Ext. Al. Cable 100% 7 m Incl. labeling & testing 6 Installation testing of BS 100% 1 pcs

system module

TIS0018.01 I BS sector modules

Installation of base station sector modules (for not integrated TRX and DDU)

Service

Installation of base station TRX module(s) including casing, fixing of earthquake protection screws, front and back covers if applicable. Installation of base station DDU/RTC module including casing, fixing of earthquake protection screws, front and back covers if applicable. Installation of grounding cable between base station TRX module(s) and Flexi base station plinth with fixing accessories (cable ties) including testing of the complete cable run if applicable Installation of delivered internal Power cabling between base station TRX module(s) and system module, including fixing accessories (cable ties). Connecting of DDU/RTC module power cable to the base station TRX module. Installation of delivered internal databus cabling between base station TRX module(s) and system module, including fixing accessories (cable ties). Installation of delivered Wide Band Combiner(s) (WBC), including power cable between the WBC and base station TRX module if applicable Installation of delivered internal RF cables between the base station TRX module and DDU/RTC module or/and Wide Band Combiners. Connecting RF antenna line to the base station DDU/RTC module.

Excludes

Page 15: TI service item description - nak-mci.ir

TI service item description Page 15

Installation of more than one base station DDU/RTC module. Installation of more than four base station TRX modules. Installation and commissioning of base station antenna line. Commissioning of base station DDU/RTC and TRX modules. Transportation of the equipment to the site.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Installation of BTS 100% 1 pcs Incl. fixing, casing, front and

DDU/RTC Module back covers 2 Installation of BTS TRX 50% 4 pcs Incl. fixing, casing, front and

Module back covers 3 Installation of grounding cable 20% 2 m Incl. testing 4 Installation of internal power cable 100% 2 pcs Length is 2m 5 Installation of internal databus cable 100% 2 pcs length is 2m 6 Installation of Wide Band Combiner 50% 6 pcs Incl. Power cable

(WBC)

7 Installation of internal RF cables 50% 22 pcs

8 Connecting of DDU/RTC power 100% 1 pcs

Cable

9 Connecting of RF antenna line 100% 2 pcs

TIS0019.01 I floor mount 19-23 cab

Installation of floor mount 19-23 inch cabinet

Service

Installation of a floor-standing 19 or 23 inch cabinet with floor fixing material and label. Installation of an AC power distribution strip for the 19 or 23 inch cabinet with mounting material. Installation of AC power cable with fixing material and labels up to the defined length. Installation of DC power cable with fixing material, labels and connectors (lugs) up to the defined length. Installation labels for AC power breaker and ground termination point (bus bar port). Installation of the grounding cable up to the defined length including labeling of the ground termination point

Excludes

Installation of DC power distribution frame.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 19-23 inch Cabinet Installation 100% 1 pcs Floor-standing 2 19-23 inch Cabinet AC Strip Install. 100% 1 pcs

3 Grounding Cable Installation 100% 7 m Incl. labeling & testing 4 AC Power Cable Installation 100% 7 m Incl. labeling & testing

Page 16: TI service item description - nak-mci.ir

TI service item description Page 16

TIS0020.01 I floor mount 19-23 open frame

Installation of floor-standing 19-23 inch open frame

Service

Installation of a floor-standing open 19 or 23 inch frame with floor fixing material and label. Installation of an AC power distribution strip for the 19 or 23 inch frame with mounting material. Installation of AC power cable with fixing material and labels up to the defined length. Installation of DC power cable with fixing material, labels and connectors (lugs) up to the defined length. Installation labels for AC power breaker and ground termination point (bus bar port). Installation of the grounding cable up to the defined length including labeling of the ground termination point.

Material

Excludes

Installation of DC power distribution or frame enclosures.

Special cases and other requirements

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark

1 19/23inch Frame Installation 100% 1 pcs DNxxx Floor-standing

2 19/23inch Frame AC Strip 100% 1 pcs DNxxx Install.

3 Grounding Cable 100% 7 m DNxxx Incl. labeling & testing Installation

4 AC/DC Power Cable 100% 7 m DNxxx Incl. labeling & testing Installation

TIS0022.01 I outdoor BS cab

Installation of outdoor base station cabinet

Service

Installation and fixing of outdoor base station cabinet Installation of grounding cable for the outdoor base station cabinet with fixing accessories (cable ties), labels and connectors (lugs) up to the defined length including testing of the complete cable run. Optional installation of cabinet Air Filter Optional installation of Smoke detector Optional installation of cabinet Site Support module.

Excludes

Installation of more than one outdoor base station cabinet.

Page 17: TI service item description - nak-mci.ir

TI service item description Page 17

Installation of 19" rack, indoor cabinet or base station plinth Transportation of the equipment to the site.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Installation of outdoor BS 100% 1 pcs Incl. fixing

cabinet

2 Installation of grounding cable 100% 3 m Incl. labeling & testing 3 Installation of Cabinet Air Filter 0% 1 pcs

4 Installation of Smoke detector 0% 1 pcs

5 Installation of Site Support module 0% 1 pcs

TIS0023.01 I panel antenna up to 3.5m

Installation of RF panel antenna higher than 0.5 and up to max. 3.5m

Service

Installation of grounding cable with fixing accessories (cable ties), labels and connectors (lugs) up to the defined length. Installation of labels for the antenna. Installation of panel antenna bigger than 0.5m and up to 2.5m with its own mounting brackets and tilting kits. Termination of the grounding cable to the grounding termination point (port of a grounding bus bar). Termination of the feeder line to the antenna (only if RF feeder exists). Adjustment of the panel antenna azimuth and tilt.

Excludes

Installation of antenna holder pole or mast. Installation of Omni or panel antenna smaller than 0.5m or bigger than 2.5m. Antenna line testing. Installation of antenna holder pole or mast. Installation of jumpers and feeder cables.

Special cases and other requirements

If the antenna line is installed in the same time like the antenna, the installation of waterproofing for the RF feeder antenna connector as well as termination of the RF feeder to the antenna are part of the antenna line installation.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Grounding Cable Installation 100% 7 m Incl. labeling 2 RF Antenna Installation 100% 1 pcs Inc. fixing & labeling 3 Adjustment of RF Antenna 100% 1 pcs Azimuth, tilting

TIS0024.01 IC cable 75/120 ohm basic

Page 18: TI service item description - nak-mci.ir

TI service item description Page 18

Installation and testing of a 75/120 ohm Cable interconnection cable with a basic length

Service

Installation of 75/120 ohm Cable for any network module up to the specified length including fixing accessories, labels and connectors Terminating of the cable to the equipment and existing DDF/MDF block Installation of a label on the DDF/MDF block Testing of the cable in its complete length

Excludes

Installation of jumpers Installation of DDF/MDF blocks Installation of cable exceeding basic length

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Cable installation 100% 20 m incl. label, termination, test

TIS0025.01 IC cable IDU-ODU basic

Installation and commissioning of IDU-ODU cable in the basic length (1+0)

Service

Installation of 75/125 ohm cable from IDU in rack up to ODU on tower. Dismantling and reassembly of the cable entry. Installation of IDU-ODU cable in the basic length with fixing accessories (clamps, fixing ties) labels, waterproofing material and grounding kits. Termination of IDU-ODU cable (connectors).

Excludes

Installation of ODU. Installation of IDU. Installation of IDU-ODU cable support structure.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 IDU-ODU cable. 100% 10 m DNxxx Incl. fixing accessories, labels,

waterproofing material and grounding kits.

2 Connectors 100% 2 pcs DNxxx

TIS0026.01 IC FO cable basic

Installation and testing/commissioning of specified length of fiber optic cable or patch cord

Service

Page 19: TI service item description - nak-mci.ir

TI service item description Page 19

Installation of up to specified length of fiber optic cable or patch cord with fixing accessories, labels and connectors (if needed). Installation of protection tube, duct, trunk or conduit for the fiber optic cable. Cleaning of FO connectors and plugging on both ends according installation manual. Testing of the fiber optic cable run in its complete length. Terminating of the fiber optic cable run to the equipment or the ODF.

Excludes

Installation of fiber optic cable and its protection above specified length.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Installation of FO Pigtail Cable 100% 1 pcs DNxxx Incl. fixing and labelling

100% 2 pcs DNxxx Pigtail splicing 2 Installation of FO Cable 100% 20 m DNxxx Incl. Protection, label, term,

test 0% 2 pcs DNxxx Connector mounting

3 Cleaning of FO connector 100% 2 pcs DNxxx Standard cleaning process 0% 2 pcs DNxxx Cleaning process for 10Gbs or higher speed FO with microscope

4 Commissioning of FO Cable 100% 20 m DNxxx Incl. Documentation

TIS0027.01 IC LAN cable basic

Installation and testing/commissioning of basic length of LAN cable

Service

Installation of LAN cable with fixing accessories, labels and connectors. Testing of the LAN cable run in its complete length (if applicable). Terminating of the LAN cable to an existing patch panel at each end.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 LAN Cable Installation 100% 10 m DNxxx Incl label, term, test

TIS0028.01 IC macro outdoor power basic

Installation and commissioning of outdoor macro DC power site support basic

Service

Installation of grounding cable with fixing accessories (cable ties), labels and connectors (lugs) up to the defined length including testing of the complete cable run. Installation of AC power cable with fixing accessories (cable ties), labels and connectors (lugs) up to the defined length including testing of the complete cable run. Installation of alarm cable with fixing accessories (cable ties), labels and connectors up to the defined length including testing of the complete cable run. Installation of Q1 cable with fixing accessories (cable ties), labels and connectors up to the defined length including testing of the complete cable run if applicable. Installation of labels for AC breaker, grounding termination points, AIB, ADM and Q1 termination point.

Page 20: TI service item description - nak-mci.ir

TI service item description Page 20

Installation of Site Support cabinet fixing materials. Installation of outdoor macro Site Support or extension cabinet and application kits including cabinet fixing. Installation of outdoor macro extension cabinet inter-cabling to the Site Support cabinet. Installation of battery shelves which are part of the delivery to the Site Support cabinet. Installation of delivered controller and rectifier units. Installation of Line Terminal Equipment unit if part of the delivery. Installation of batteries. Installation of delivered internal cabling. Commissioning of the Site Support cabinet units and rectifiers including LTE if part of the delivery.

Excludes

Installation and commissioning of more than one Support Site cabinet. Installation and commissioning of indoor macro or micro Support Site cabinet. Installation of additional battery shelves. Testing of external alarms from AIB or ADB up to alarm generating sensors. Transportation of the equipment to the site.

Special cases and other requirements

This Service item covers installation of one basic cabinet only. Cross-connecting of external alarms in Alarm Distribution Module is not included in this service item, because it is assumed that the incoming alarms and the alarm cable share the same ADM.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Installation of Grounding Cable 100% 10 m Incl. labeling & testing 2 Installation of DC Power Cable 100% 10 m Incl. labeling & testing 3 Installation of Ext. Al. Cable 0% 10 m Incl. labeling & testing 4 Installation of remote access Cable (if 100% 10 m Incl. labeling & testing

applicable) 5 Installation of Cabinet 100% 1 pcs Incl. fixing 6 Installation of Batt. Shelf 100% 2-3 pcs

7 Installation of Battery string 100% 2-3 pcs Incl. Intercon. Cables 8 Installation of PIUs, Rectifiers 100% 8-12 pcs 2 PIUs, 6 rectifiers 11 Commissioning of Site Support 100% 1 pcs Docum., alarm test incl.

TIS0029.01 IC MW HSB or dual pol kit

Installation and Commissioning of microwave Hot Stand-by kit or circulator

Service

Installation of grounding cable up defined length with fixing accessories (cable ties), labels and connectors (cable lugs) including testing of the grounding cable in its complete length. Termination of the grounding cable to the grounding termination point (port on a grounding bus bar). Installation of Hot Stand-by Kit or circulator Installation of an additional outdoor unit (if applicable) and the coupler. Commissioning of the additional outdoor unit.

Page 21: TI service item description - nak-mci.ir

TI service item description Page 21

Testing of the link with Hot Stand-by Kit or circulator Re-commissioning of the indoor unit.

Excludes

Installation of a second microwave antenna. Installation and alignment of MW antennas.

Special cases and other requirements

This Service Item is normally ordered in pairs unless it is used as part of the replacement of one Hot Stand-by kit.

The supply of labels and grounding cable upto 1m is also included in this Service Item.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Grounding Cable Installation 100% 1 m DNxxx Incl. labeling 2 HSB Kit Installation 100% 1 pcs xxx Incl. labeling 3 Circulator Installation 100% 1 pcs xxx Incl. labeling 4 ODU Installation 0% 1 pcs xxx Incl. labeling 5 ODU Commissioning 0% 1 pcs xxx

6 Link Testing 100% 1 pcs xxx Link testing for HSB or circulator

7 IDU Commissioning 100% 1 pcs xxx

TIS0030.01 IC MW ODU

Installation and commissioning of microvawe outdoor unit

Service

Installation of the microwave outdoor unit including the suspension unit if delivered (only used for PowerHopper) and alignment unit, if applicable (including Rough alignment) Installation of waveguide if applicable. Installation of grounding cable up to defined length with fixing accessories (cable ties), labels and connectors (cable lugs) including testing of the grounding cable in its complete length. Termination of the grounding cable to the grounding termination point (port of a grounding bus bar). Installation of outdoor unit label or sticker for marking of the dish. Termination of a TRS cable to the Outdoor Unit and installation of waterproofing materials for the ODU-TRS cable connector (if TRS cable exists). Commissioning of the outdoor unit (including Fine alignment)

Excludes

Installation of microwave antenna. Installation of the antenna pole and bracket. Installation of FlexBus cable.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Grounding Cable Installation 100% 1 m DNxxx Incl. labeling 2 ODU Installation 100% 1 pcs DNxxx Incl. Rough alignment and

labeling

Page 22: TI service item description - nak-mci.ir

TI service item description Page 22

3 Suspension Installation 0% 1 pcs only with PowerHopper 4 Waveguide Installation 0% 1 pcs

5 ODU Commissioning 100% 1 pcs DNxxx Incl. Fine alignment

TIS0031.01 IC ODU and dish up to 120cm

Installation and Commissioning of outdoor unit and dish up to 120cm

Service

Installation of outdoor unit including the suspension unit if delivered (only used for PowerHopper) and alignment unit (including the rough alignment). Installation of waveguide if applicable. Installation of microwave antenna support rod with fixing accessories. Installation of microwave antenna up to 120cm in diameter. Installation of grounding cable up to defined length with fixing accessories (cable ties), labels and connectors (cable lugs) including testing of the grounding cable in its complete length. Termination of the grounding cable to the grounding termination point (port of a grounding bus bar). Installation of outdoor unit label or sticker for marking of the dish. Termination of a IDU-ODU cable to the Outdoor Unit. Application of waterproofing materials on the ODU connector. Commissioning of the outdoor unit (including the fine alignment).

Excludes

Installation of the antenna pole and bracket. Installation of IDU-ODU cable. Installation and commissioning of TRS Outdoor Unit and MW antenna other than 120cm in diameter.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Grounding Cable Installation 100% 1 m DNxxx Incl. labeling 2 ODU Installation 100% 1 pcs DNxxx Incl. Rough alignment and

labeling 3 Suspension Installation 0% 1 pcs only with PowerHopper 4 Waveguide Installation 0% 1 pcs

5 Ant. Support Rod Installation 0% 1 pcs DNxxx

6 MW Antenna Installation 100% 1 pcs DNxxx Diam. up to 120cm 7 ODU Commissioning 100% 1 pcs DNxxx Incl. Fine alignment

TIS0032.01 IC ODU and dish up to 60cm

Installation and Commissioning of outdoor unit and dish up to 60cm

Service

Installation of outdoor unit including the suspension unit if delivered (only used for PowerHopper) and alignment unit (including the rough alignment). Installation of microwave antenna up to 60cm in diameter.

Page 23: TI service item description - nak-mci.ir

TI service item description Page 23

Installation of waveguide if applicable. Installation of grounding cable up to the defined length with fixing accessories (cable ties), labels and connectors (cable lugs) including testing of the grounding cable in its complete length. Termination of the grounding cable to the grounding termination point (port of a grounding bus bar). Installation of outdoor unit label or sticker for marking of the dish. Termination of a FlexBus to the Outdoor Unit and installation of waterproofing materials for the ODU-FlexBus connector (if FlexBus exists). Commissioning of the outdoor unit (including the fine alignment)

Excludes

Installation of the antenna pole and bracket. Installation of FlexBus cable. Installation and commissioning of integrated outdoor unit and antenna (MetroHopper).

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Grounding Cable Installation 100% 1 m DNxxx Incl. labeling 2 ODU Installation 100% 1 pcs DNxxx Incl. Rough alignment and

labeling 3 Suspension Installation 0% 1 pcs only with PowerHopper 4 Waveguide Installation 0% 1 pcs

5 MW Antenna Installation 100% 1 pcs DNxxx Diam. up to 60cm 6 ODU Commissioning 100% 1 pcs DNxxx Incl. Fine alignment

TIS0033.01 IC PCM x-connection 75ohm

Installation and testing/commissioning of 75 ohm PCM cross-connection cable

Service

Installation of 75 ohm PCM cross-connection cable with fixing accessories and labels. Terminating of the PCM cross-connection cable to an existing DDF block at each end. Testing of the PCM cross-connection cable in its complete length including jumpers. Installation of analogue X.25 cross-connection cable with fixing accessories and labels. Terminating of the analogue X.25 cross-connection cable to an existing DDF block at each end. Installation of clock synchronization cross-connection cable with fixing accessories and labels. Terminating of the clock synchronization cross-connection cable to an existing DDF block at each end.

Material

Excludes

Installation of 120 ohm PCM cross-connection cable.

Special cases and other requirements

Bill of Quantities

Page 24: TI service item description - nak-mci.ir

TI service item description Page 24

Pos Category Occurrence Qnt Unit Remark

1 PCM X-Con. 100% 5 m Incl label, term, test Cable Installation

0% 5 m Incl label, term, test

0% 15 m Incl label, term, test

2 X.25 X-Con. 100% 5 m Incl label, term, test Cable Installation

3 Clock X-Con. 100% 5 m Incl label, term, test Cable Installation

0% 15 m Incl label, term, test

TIS0034.01 IC PDF

Installation and commissioning of power distribution

Service

Installation of DC power cable in the defined length with fixing accessories, labels and connectors (cable shoes). Installation of grounding cable up to the defined length with fixing accessories, labels and connectors (cable lugs). Installation of labels for terminating points of the DC power cable (DC breakers). Installation of label for the Power Distribution Frame or panel. Installation of the Power Distribution Frame in a19-inch cabinet. Installation of a distribution panel on the wall or in a cabinet. Testing/commissioning of the Power Distribution Frame and measurement of voltage on the output breakers

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Installation 100% 1 pcs DNxxx 19-inch PDF incl. labeling &

testing 0% 1 pcs DNxxx Power distribution panel incl. labeling & testing

2 Grounding Cable Installation 100% 3 m DNxxx Incl. labeling & testing 3 DC Power Cable Installation 100% 14 m DNxxx Incl. labeling & testing

TIS0035.01 IC RG-214 Flexbus or IFL run basic

Installation and commissioning of one Flexbus run (i.e. RG214 for FH or LCF38-50 for PH) in the basic length

Service

Installation of Flexbus cable (RG-214 or LCF38-50) with fixing accessories (clamps, cable ties for taping), labels, waterproofing material and kits, grounding kits, and connectors in the defined length. Installation of jumper cables with fixing accessories (cable ties) and labels. Termination of the grounding kits to grounding termination points (ports of grounding bus bars).

Page 25: TI service item description - nak-mci.ir

TI service item description Page 25

Termination (including waterproofing) of the Flexbus run to the TRS Outdoor Unit and TRS Indoor Unit. Commissioning/testing of the complete Flexbus run.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 FlexBus Installation 100% 10 m DNxxx Inc. label, g.-k., sealing

100% 2 pcs DNxxx Connector fitting 2 Jumper Installation 0% 1 m DNxxx Incl. label & sealing 3 FlexBus Run Testing 100% 1 pcs DNxxx

TIS0036.01 IC RG-223 Flexbus run basic

Installation and commissioning of one RG-223 Flexbus run in the basic length

Service

Installation of RG-223 coaxial cable with fixing accessories (clamps, cable ties for taping), labels, waterproofing material and kits, grounding kits, and connectors in the defined length. Installation of jumper cables with fixing accessories (cable ties) and labels for the RG-223 cable. Termination of the grounding kits to grounding termination points (ports of grounding bus bars). Termination (including waterproofing) of the RG-223 feeder line to the TRS Outdoor Unit and TRS Indoor Unit. Commissioning/testing of the complete RG-223 run.

Excludes

Installation of RG-223 cable above the defined length.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Flexbus Installation 100% 10 m DNxxx Inc. label, g.-k., sealing

100% 2 pcs DNxxx Connector fitting 2 Jumper Installation 0% 0 m DNxxx Incl. label & sealing 3 Flexbus Run Testing 100% 1 pcs DNxxx

TIS0037.01 IC SDH MW indoor unit

Installation and commissioning of a SDH split MW indoor unit

Service

Installation of Indoor Unit into a 19 inch, N3 frame, cabinet.or Outdoor Case. Installation of DC power cable in the defined length with fixing accessories, labels and connectors Installation of management interface cable in the defined length with fixing accessories, labels and connectors.

Page 26: TI service item description - nak-mci.ir

TI service item description Page 26

Installation of external alarms cable in the defined length with fixing accessories, labels and connectors (if applicable, e.g. for repeater sites). Installation of labels. Termination of IDU-ODU cable to the Indoor Unit . Installation of plug-in units into the Indoor Unit of the basic configuration. Installation of Auxiliary traffic channels in the defined length with fixing accessories, labels and connectors (if applicable, e.g. for repeater sites). Installation of adapting cables in FOC installation. Installation of an optional Line interface plug-in board (155Mb/s). Commissioning of the transmission indoor unit.

Excludes

Installation of 19 inch, N3 frame, cabinet.or Outdoor Case Installation of PCM cables. Installation of optical fiber cables. Installation of the IDU-ODU cable. Installation of PCM add/drop.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 TRS Indoor Unit Installation 100% 1 pcs DNxxx Incl labeling 2 DC Power Cable Installation 100% 3 m DNxxx Incl. labeling & testing

0% 0.5 m DNxxx FOC installation: connection within FOC

3 Grounding Cable Installation 100% 3 m DNxxx Incl labeling & testing 0% 0.5 m DNxxx FOC installation: connection within FOC

4 Mgt Cable Installation 100% 10 m DNxxx Incl labeling & testin 100% 10 m DNxxx Not applicable for installation of Indoor Unit into FOC

5 Auxiliary traffic channels 100% 1 pcs DNxxx Lug crimping/Conn. mounting 6 Ext. Al. Cable Installation 100% 7 m DNxxx Incl labeling & testing

0% 0.5 m DNxxx FOC installation: connection within FOC

7 Auxiliary traffic channels Inst. 100% 6 pcs DNxxx Incl labeling & testing 8 (155 Mb/s) installation 100% 1 pcs xxx Incl labeling & testing 9 Adapting cables installation 0% 1 set DNxxx FOC installation:connection

within outdoor cables 10 TRS Indoor Unit Commiss. 100% 1 pcs DNxxx

11 Line cable 100% 4 pcs DNxxx Incl labeling & testing

TIS0038.01 IC TRS indoor unit

Installation and commissioning of a transmission indoor unit

Service

Installation of fixing materials and accessories for the Indoor Unit. Installation of Indoor Unit into a 19 inch, N3 frame, cabinet or Outdoor Case Installation DC power cable in the defined length with fixing accessories, labels and connectors Installation of management cable in the defined length with fixing accessories, labels and connectors. Installation of external alarms cable in the defined length with fixing accessories, labels and

Page 27: TI service item description - nak-mci.ir

TI service item description Page 27

connectors (if applicable, e.g. for repeater sites). Installation of labels for DC breakers. Termination of a IDU-ODU cable to the Indoor Unit Installation of plug-in units into the Indoor Unit of the basic configuration. Installation of adapting cables. Installation of Line cable Commissioning of the transmission indoor unit.

Excludes

19 inch, N3 frame, cabinet.or Outdoor Case. Installation of PCM cables. Installation of the IDU-ODU cable. Installation of an integrated Indoor Unit. Installation of additional TRS sub-module. Installation of PCM add/drop.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 TRS Indoor Unit Installation 100% 1 pcs DNxxx Incl labeling 2 DC Power Cable Installation 100% 3 m DNxxx Incl. labeling & testing

0% 0.5 m DNxxx FOC installation: connection within FOC

3 Grounding Cable Installation 100% 3 m DNxxx Incl labeling & testing 0% 0.5 m DNxxx FOC installation: connection within FOC

4 Management Cable Installation 100% 10 m DNxxx Incl labeling & testing 5 Ext. Al. Cable Installation 100% 7 m DNxxx Incl labeling & testing

0% 0.5 m DNxxx FOC installation: connection within FOC

6 Line cable installation 100% 2 pcs DNxxx Incl labeling & testing 7 TRS Indoor Unit Commiss. 100% 1 pcs DNxxx

8 Adapting cables installation 0% 1 set DNxxx FOC installation:connection within outdoor cables

TIS0039.01 Implementation supervising BS-CT

Supervising of network element implementation and commissioning on a Base Station or Cellular Transmission sites

Service

Implementation and commissioning supervising activities for a network element being implemented on a Base Station or Cellular Transmission site, which may include the following Supervising of implementation activities at site in line with local implementation processes (including participation in the Pre Installation Site Meeting (PSIM), coordination of the implementation activities at the site. Verification of delivery-, installation-, commissioning-, integration- and customer signoff phases according to the contract scope. First line technical assistance for field teams and act as main contact with project team for fault resolution. Reporting of site-specific implementation progress to project management and updating of project tools. Controlling, scheduling and progress monitoring of field based implementation

Page 28: TI service item description - nak-mci.ir

TI service item description Page 28

resources. Compilation of Site or Link Folder from documents created in course of the implementation throughout the implementation process until customer signoff. Ensuring the site quality.

Excludes

Performance of site surveys. Performance of installation planning.

Special cases and other requirements

Reporting of site-specific implementation progress to Nokia Siemens Networks project management and updating of Nokia Siemens Networks’s project tools, including but not limited to E doc and E tracker. All completed work should be updated in the appropriate tools on the day of the activity (or no later than 10.00am the following working day) To include site logs, electronic certificates & test results, completion dates, Site Deficciency Reports(SDR)and data storeage files. The Partner is resp. for the following act • In field 1st line support for the deployed resources, Responsible for "first time right" site visit

success for activities within their region. • Every effort to proactively clear site SDR’s during planned works. As a minimum all partner and

as many Nokia Siemens Networks responsible SDR’s are closed at the commissioning activity. • On milestone completion, a warranty of the site works is complete, all certificates are

received and logged and the whole site is ready for customer acceptance – Process to be defined and agreed.

• First line technical support for field teams

• Spares management / provisioning for teams within their control (excluding actual returns loop spare handling managed nationally by partner organisation)

• Main contact with project team for fault resolution • Exceptions reporting and responsible for "Lessons Learned" meetings

• Ensure teams are working to latest version documentation, procedures and software

releases.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Supervising of BS-CT 100% 1 pcs

Implementation

TIS0040.01 Installation planning BS-CT

Installation planning for base station or transmission sites

Page 29: TI service item description - nak-mci.ir

TI service item description Page 29

Service

Installation planning activities for base station or transmission sites, which may include the following Preparation of Site Layout drawings and sketches based on existing site documentation and drawings as part of the Site Folder for one network element or a site with all related equipment (DC power supply, 19-inch frames or cabinets, feeder and antenna lines, antennas, peripherals, lamp panels). Listing of Ancillary Materials and determining their quantities (can be part of the Site Folder or Link Folder) for the site or the network element and all related equipment.

Excludes

Performance of site survey for installation planning. Installation planning for additional network elements. Implementation supervisioning.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 BS-CT Inst. Planning 100% 1 pcs DNxxx

TIS0041.01 Rem Flexbus per 10m

Removal of Flexbus cable per 40 meters

Service

Disconnection of the grounding kits from the grounding termination points (ports of bus bars) if applicable. Disconnection and deinstallation of Flexbus Cable (e.g. RG-214/RG-223) including cable fixing, grounding kits and jumper cables (if applicable) on the defined lengthrs. Packaging of the removed grounding kits and clamps. Collecting of the removed items in a designated area at the site.

Material

Excludes

Special cases and other requirements

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 Removal of cable 100% 10 m Removal and spooling up

Page 30: TI service item description - nak-mci.ir

TI service item description Page 30

TIS0042.01 Rem MW ODU

Removal of microvawe outdoor unit

Service

De-commissioning of the MW outdoor unit and additional MW outdoor unit as part of the Hot Stand-by Kit (if applicable). Disconnection of the TRS cable from the MW outdoor unit (if TRA cable exists). Disconnection of the grounding cable from the grounding termination point and MW outdoor unit. Removal of the grounding cable including cable fixing up to the defined length. De-installation and packaging of the MW outdoor unit and alignment unit as well as the additional MW outdoor unit as part of the Hot Stand-by Kit (if applicable). Disconnection of coupler, removal and packaging of Hot Stand-By Kit (if applicable). Collecting of the removed items in a designated area at the site.

Material

Excludes

Removal of microwave antenna. Removal of the FlexBus cable.

Special cases and other requirements

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 ODU Decommissioning 100% 1 pcs

2 Cable Removal 100% 10 m

3 HSB Kit Deinstallation 0% 1 pcs Incl. packaging

4 ODU Deinstallation 100% 1 pcs Incl. packaging

TIS0043.01 Rem ODU and dish up to 120cm

Removal of outdoor unit and MW antenna up to 120cm

Service

De-commissioning of the TRS Outdoor Unit and additional TRS Outdoor Unit as part of the Hot Stand-by Kit (if applicable). Disconnection of theIDU-ODU cable from the TRS Outdoor Unit

Page 31: TI service item description - nak-mci.ir

TI service item description Page 31

Disconnection of the grounding cable from the grounding termination point and TRS Outdoor Unit. Removal of the grounding cable including cable fixing up to the defined length. De-installation and packaging of the microwave antenna up 120cm in diameter. De-installation and packaging of the TRS Outdoor Unit and alignment unit as well as the additional TRS Outdoor Unit as part of the Hot Stand-by Kit (if applicable). Disconnection of coupler, removal and packaging of Hot Stand-By Kit. De-installation and packaging of the microwave antenna support rod with mounting accessories. Collecting of the removed items in a designated area at the site.

Material

Excludes

Removal of microwave antenna with the diameter other than 120cm. Removal of theIDU-ODU cable.

Special cases and other requirements

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 ODU 100% 2 pcs

Decommissioning

2 Cable Removal 100% 10 m

3 MW Ant. 100% 1 pcs Up to 120 cm incl. Deinstallation packaging

4 MW Ant. Support 100% 1 pcs Incl. packaging Frame Deinst.

5 HSB Kit 0% 1 pcs Incl. packaging Deinstallation

6 ODU 100% 2 pcs Incl. packaging Deinstallation

TIS0044.01 Rem ODU and dish up to 60cm

Removal of outdoor unit and MW antenna up to 60cm

Service

De-commissioning of the TRS Outdoor Unit and additional TRS Outdoor Unit as part of the Hot Stand-by Kit (if applicable). Disconnection of theIDU-ODU cable from the TRS Outdoor Unit Disconnection of the grounding cable from the grounding termination point and TRS Outdoor Unit. Removal of the grounding cable including cable fixing up to the defined length. De-installation and packaging of the microwave antenna up 60cm in diameter. De-installation and packaging of the TRS Outdoor Unit and alignment unit as well as the additional TRS Outdoor Unit as part of the Hot Stand-by Kit (if applicable). Disconnection of coupler, removal and packaging of Hot

Page 32: TI service item description - nak-mci.ir

TI service item description Page 32

Stand-By Kit. De-installation and packaging of the microwave antenna support rod with mounting accessories. Collecting of the removed items in a designated area at the site.

Material

Excludes

Removal of microwave antenna with the diameter other than 60cm. Removal of theIDU-ODU cable.

Special cases and other requirements

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark

1 ODU 100% 2 pcs DNxxx

Decommissioning

2 Cable Removal 100% 10 m DNxxx

3 MW Ant. 100% 1 pcs DNxxx Up to 60 cm incl. packaging Deinstallation

4 MW Ant. Support 100% 1 pcs DNxxx Incl. packaging Frame Deinst.

5 HSB Kit 0% 1 pcs DNxxx Incl. packaging Deinstallation

6 ODU 100% 2 pcs DNxxx Incl. packaging Deinstallation

TIS0045.01 Rem TRS indoor unit

Removal and packing of a transmission indoor unit including 16x2 upgrade panel (if applicable)

Service

Decommissioning and power-down of the TRS Indoor Unit. Disconnection of IDU-ODU cables and incoming and outgoing PCM cables. Disconnection and removal of the DC power cable up to the defined length. Disconnection and removal of the management interface cable up to the defined length. Disconnection and removal of the external alarms cable up to the defined length. Disconnection and removal of FlexBus, PCM and management cables between the TRS Indoor Unit and the Extension Unit (if applicable). Removal of labels from the DC breaker and TRS Indoor Unit. Removal and packaging of the plug-in units from the TRS Indoor Unit and the Extension Unit. Removal and packaging of the Extension Unit (if applicable). Removal and packaging of the TRS Indoor Unit. Collecting of the removed items in a designated area at the site.

Material

Page 33: TI service item description - nak-mci.ir

TI service item description Page 33

Excludes

Removal of IDU-ODU cable. Removal of TRS Outdoor Unit.

Special cases and other requirements

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark

1 Removal of 100% 35 m DNxxx Incl. fixing materials and Cable labels

2 Removal of TRS 100% 1 pcs DNxxx Incl. decomm., labels, Ind. Unit packaging

3 Removal of 0% 1 pcs DNxxx Incl. packaging Extension Unit

TIS0046.01 Site survey BS site

Site survey BS site

Service

Conduct of a site survey on a base station site and preparation of related documents including photographs (if applicable) and the relevant site survey check list.

Excludes

Installation planning. Implementation supervisioning.

Special cases and other requirements

This Service Item may include multiple network elements, which are implemented at the same phase at the same site.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Site Survey 100% 1 pcs DNxxx Per survey

TIS0047.01 Site survey TRS

Site survey of a micro wave transmission site (one end)

Service

Conduct of a site survey of a transmission site (one end of the link) and preparation of related documents including photographs (if applicable) and the relevant site survey check list.

Excludes

Page 34: TI service item description - nak-mci.ir

TI service item description Page 34

Installation planning. Implementation supervisioning. Site survey for the other end of the complete link

Special cases and other requirements

This Service Item may include multiple network elements, which are implemented at the same phase at the same site. In case of a microwave link, this Service Item shall be ordered once for each end of the link.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Site Survey TRS site 100% 1 pcs Site Survey One end of the link

template document

TIS0048.01 Transport DOP/Site to Site 0-3,5t regulr

Transportation of low-volume cargo

Service

Carrying or moving cargo from the storage area, or in case of removal, from a designated area at the site, and loading of the cargo onto the vehicle as described below. Transportation of tools, materials or equipment in a truck/lorry with the payload capacity up to 3.5 tons for an initial distance from the storage area to site. (or return travel of the vehicle). Transportation of the same volume of cargo by train. Travel by ferry for the passangers and the vehicle in both directions if needed. Carrying or moving the cargo from the vehicle into the equipment room, battery room, rooftop or other designated area at the site, or in case of removal, into the storage area. Accommodation of the or passangers and secure parking of the vehicle if overnight stay is needed. Insurance of the persons, vehicle, tools, materials and equipment within the scope of this Service Items.

Excludes

Transportation of cargo in a vehicle with the payload capacity above 3.5 tons. Transportation by helicopter. Hoisting of the cargo by crane. Travel of personnel other than the driver and the aids for cargo loading and unloading.

Special cases and other requirements

This Service Item also covers the cases where one aditional stop is made on the route to and on the route back from the destination for the purpose of loading or unloading additional cargo up to the capacity of the vehicle, which is used especially for microwave links. In case of shipping the cargo by airplane, this Service Item shall be ordered in such a quantity so that the price of the air-ticket and handling or storing of the cargo at the airport is compensated.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark

Page 35: TI service item description - nak-mci.ir

TI service item description Page 35

1 Transport DOP/Site to Site 0+3,5t 100% 200 km DNxxx 100km in 2 dirs, accom. regulr

TIS0049.01 Travel

Travel of persons to the site up to

Service

Travel of one or multiple persons by car (station wagon, MPV, or off-road SUV) or train within a region/nation in both directions. Transportation of tools, materials or equipment in the same car up to the capacity of the trunk or carrying capacity of the persons and moving of the transported tools, materials or equipment onto and from the site (equipment room, battery room, rooftop, any other part of the site). Travel by ferry for the person(s) and the car in both directions if needed. Travel time cost of the person or persons including accommodation if overnight stay is needed. Insurance of the persons, vehicles, tools, materials and equipment within the scope of this Service Items.

Excludes

Transportation of goods above the capacity of the car or the persons. Travel by helicopter.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Travel 100% 1 National

TIS0050.01 Travel add (Extra site visit)

Travel additional distance or additional site visit.

Service

Travel of one or multiple persons by car (station wagon, MPV, or off-road SUV) or train for an additional distance in both directions. Transportation of tools, materials or equipment in the same car up to the capacity of the trunk or carrying capacity of the persons and moving of the transported tools, materials or equipment onto and from the site (equipment room, battery room, rooftop, any other part of the site). Travel by train for the person(s) and the car in both directions if needed. Travel by ferry for the person(s) and the car in both directions if needed. Travel by helicopter for the person(s) in both directions if needed. Travel by plane for the person(s) in both directions if needed. Travel by any other means for the person(s) in both directions if needed. Travel time cost of the person or persons including accommodation if overnight stay is needed. Insurance of the persons, vehicles, tools, materials and equipment within the scope of this Service Item.

Page 36: TI service item description - nak-mci.ir

TI service item description Page 36

Material

Excludes

Transportation of goods above the capacity of the car or the persons.

Special cases and other requirements

This Service Item also covers the cases where one additional stop is made on the route to and the route from the destination.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 Travel addittional 100% 50 km

TIS0051.01 Travel TRS

Travel transmission

Service

All travel related to carry out the tasks in the sales package by one or more people on a MWR end or similar task, which normally only takes part of a day to implement. Travel by car (station wagon, MPV, or off-road SUV), or train or other means needed for the team to get to the site. Travel by ferry for the person(s) and the car if needed. Travel time cost of the person or persons including accommodation if overnight stay is needed as long as required for completing the agreed tasks in the sales package. Transportation of tools, materials or equipment in the same car up to the capacity of the trunk or carrying capacity of the persons and moving of the transported tools, materials or equipment onto and from the site (equipment room, battery room, rooftop, any other part of the site). Insurance of the persons, vehicles, tools, materials and equipment within the scope of this service item. Including transportation of equipment from WH to Site

Excludes

Travel by helicopter. Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Travel Transmission 100% 1 pcs All travel related to the sales

package

TIS0052.01 I BS RF modules

Installation of RF base station RF modules.

Page 37: TI service item description - nak-mci.ir

TI service item description Page 37

Service

Installation of base station TRX module(s) including casing, fixing of earthquake protection screws, front and back covers if applicable. Installation of base station DDU/RTC module including casing, fixing of earthquake protection screws, front and back covers if applicable. Installation of grounding cable between base station TRX module(s) and base station plinth with fixing accessories (cable ties) including testing of the complete cable run if applicable Installation of delivered internal Power cabling between base station TRX module(s) and system module, including fixing accessories (cable ties). Connecting of DDU/RTC module power cable to the base station TRX module. Installation of delivered internal data bus cabling between base station TRX module(s) and system module, including fixing accessories (cable ties). Installation of delivered Wide Band Combiner(s), including power cable between the WBC and base station TRX module if applicable Installation of delivered internal RF cables between the base station TRX module and DDU/RTC module or/and Wide Band Combiners. Connecting RF antenna line to the base station DDU/RTC module.

Excludes

Installation of more than three base station DDU/RTC module. Installation of more than four base station TRX modules. Installation and commissioning of base station antenna line. Commissioning of base station DDU/RTC and TRX modules. Transportation of the equipment to the site.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Installation of BTS 100% 1 pcs Incl. fixing, casing, front and

DDU/RTC Module back covers 2 Installation of Flexi BTS TRX 50% 4 pcs Incl. fixing, casing, front and

Module back covers 3 Installation of grounding cable 20% 2 m Incl. testing 4 Installation of internal power cable 100% 2 pcs Length is 2m 5 Installation of internal databus cable 100% 2 pcs length is 2m 6 Installation of Wide Band Combiner 50% 6 pcs Incl. Power cable

(WBC)

7 Installation of internal RF cables 50% 22 pcs

8 Connecting of DDU/RTC power 100% 1 pcs

Cable

9 Connecting of RF antenna line 100% 2 pcs

TIS0053.01 Rem macro BS or power cabinet

Uninstalling and removing of BS/power cabinet

Service

Uninstalling of BS/power cabinet units and cable in the defined length with removing accessories.

Excludes

Page 38: TI service item description - nak-mci.ir

TI service item description Page 38

Travel Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Un-installation 100% 1 pcs 19-inch BS/power cabinet.

TIS0054.01 IC Micro BS Power module

Installation and Commissioning testing of Micro base station power module

Service

Installation of power plug-in unit.Installation of base station Power module including casing, fixing of earthquake protection screws, front and back covers if applicable. Installation of grounding cable between Micro base station power module and base station plinth with fixing accessories (cable ties) including testing of the complete cable run. Installation of DC power cable with fixing accessories (cable ties), labels and connectors (shoes) up to the defined length if applicable including testing of the complete cable runs. Installation of alarm cable with fixing accessories (cable ties), labels and connectors up to the defined length including testing of the complete cable run. Installation of labels for DC breakers.

Excludes

Installation of more than one Micro base station power module. Installation

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Installation of Flexi BS Power 100% 1 pcs Incl. fixing, casing, front and

Module back covers 2 Installation of Grounding Cable 100% 2 m Incl. testing 3 Installation of DC Power Cable 100% 10 m Incl. labeling & testing 4 Installation of Ext. Al. Cable 100% 7 m Incl. labeling & testing

TIS0055.01 Rem panel antenna up to 2.5m

Dismantle of RF panel antenna higher than 0.5 and up to max. 2.5m

Service

Disconnection of the feeder cable from the antenna Un-Installation of panel antenna bigger than 0.5m and up to 2.5m with its own mounting brackets and tilting kits. Disconnection of the feeder cable from the antenna

Termination of the feeder line to the antenna Removal of the grounding cable including cable fixing up to the defined length. De-installation and packaging of the Antenna. Collecting of the removed items in a designated area at the site.

Page 39: TI service item description - nak-mci.ir

TI service item description Page 39

Preparing asset sheet of uninstalled equipments.

Excludes

Un-Installation of antenna holder pole or mast. Antenna line testing. Un-Installation of antenna holder pole or mast. Un-Installation of jumpers and feeder cables.

Special cases and other requirements Water proofing of antenna ports are mandatory to avoid damaging antenna.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Grounding Cable un-Installation 100% 7 m Incl. labeling 2 RF Antenna un-Installation 100% 1 pcs Inc. fixing & labeling

TIS0056.01 Rem 1-2 antenna line add

Un-Installation of maximum 10m of 1/2" antenna line.

Service

Un-Installation of 10 meters of 1/2" feeder cable with fixing accessories (clamps, cable ties), grounding kits , jumpers and waterproofing materials.

Excludes

Un Installation of RF antenna

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Feeder Cable un-Installation 100% 10 m Incl fixing and jumpers

TIS0057.01 Rem 7-8 antenna line add

Un-Installation of maximum 10m of 7/8" antenna line.

Service

Un-Installation of 10 meters of 7/8" feeder cable with fixing accessories (clamps, cable ties), grounding kits , jumpers and waterproofing materials.

Excludes

Un Installation of RF antenna

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

Page 40: TI service item description - nak-mci.ir

TI service item description Page 40

1 Feeder Cable un-Installation 100% 10 M Incl fixing and jumpers

TIS0058.01 Swap documentation

Swap detail design and document.

Service Preparing before and after swap detail design, asset sheet.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Site plan 100% 1 pcs

2 Asset sheet 100% 1 pcs

3 Completion of site folder 100% 1 pcs

TIS0059.01 Rem micro BS equipment

Uninstalling and removing of BS/power module of micro site

Service

Uninstalling of plinth x 3 Uninstalling of system module including bracket and casing (if applicable) x1 Uninstalling of RF module including brackets and casing (if applicable) x 2 Uninstalling related cable and accessories of micro equipment.

Excludes Travel

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Un-installation 100% 1 pcs Micro equipment.

TIS0060.01 Site Audit & Documentation

Sit audit and reporting

Service

Site visit Completing Report (Pre-defined Excel form) Preparing Detail design

Page 41: TI service item description - nak-mci.ir

TI service item description Page 41

This service is to provide requested data which is defined by customer for existing node in network. \

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 Site audit and compete Report preparation 100% 1 pcs

TIS0063.01 Fusion and OTDR test

Service of fusion and OTDR test

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 fusion and OTDR test 100% 1 pcs

TIS0065.01 Repeater Telecom implementation Service of installation commissioning and integration of Repeater site.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1

Equipment installation commissioning and integration for a repeater site 100% 1 pcs

TIS0066.01 High Power Repeater acceptance and documentation Service of acceptance test and documentation to deliver repeater site to customer

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 Acceptance visit test and documentation and site delivery 100% 1 pcs

Page 42: TI service item description - nak-mci.ir

TI service item description Page 42

to customer.

TIS0066.02 Low Power Repeater acceptance and documentation Service of acceptance test and documentation to deliver repeater site to customer

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1

Acceptance visit test and documentation and site delivery to customer. 100% 1 pcs

TIS0068.01 DAS installation (feeder or fiber) per 10m

Service of installation of DAS system feeder or fiber including fixing cable

Provisioning and installation of required feeder or fiber protections such as every types of conduit, PVC pipe, duct or trunk. Installation of connectors and sealing connections if necessary. Provisioning and installation of standard labels for all DAS components. Provisioning and installation of all needed connectors Provisioning and installation of all necessary fixing accessories.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 DAS Installation Feeder or Fiber 100% 10 M

TIS0071.01 I BS Remote RF modules

Installation of Remote RF modules

Service

Installation of base station TRX module(s) including casing, fixing of earthquake protection screws, front and back covers if applicable. Installation of base station DDU/RTC module including casing, fixing of earthquake protection screws, front and back covers if applicable. Installation of grounding cable between base station TRX module(s) and base station plinth with fixing accessories (cable ties) including testing of the complete cable run if applicable

Page 43: TI service item description - nak-mci.ir

TI service item description Page 43

Installation of delivered internal Power cabling between base station TRX module(s) and system module, including fixing accessories (cable ties). Connecting of DDU/RTC module power cable to the base station TRX module. Installation of delivered internal data bus cabling between base station TRX module(s) and system module, including fixing accessories (cable ties). Installation of delivered Wide Band Combiner(s), including power cable between the WBC and base station TRX module if applicable Installation of delivered internal RF cables between the base station TRX module and DDU/RTC module or/and Wide Band Combiners. Connecting RF antenna line to the base station DDU/RTC module. Instillation of fiber and power cable between remote RF module and system module with fixing material

Excludes

Installation of more than 1 base station DDU/RTC module. Installation of more than four base station TRX modules. Installation and commissioning of base station antenna line. Commissioning of base station DDU/RTC and TRX modules. Transportation of the equipment to the site.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 Installation of BTS 100% 1 pcs Incl. fixing, casing, front and

DDU/RTC Module back covers 2 Installation of Remote radio unit 100% 1 pcs Incl. fixing, casing, front and

back covers 3 Installation of grounding cable 20% 2 m Incl. testing 4 Installation of power cable 100% 40 m Up to 40m

5 Installation of internal databus cable/fiber 100% 40 m Up to 40 m

6 Installation of Wide Band Combiner 50% 1 pcs Incl. Power cable (WBC)

7 Installation of internal RF cables 50% 3 pcs

8 Connecting of DDU/RTC power 100% 1 pcs

Cable

9 Connecting of RF antenna line 100% 2 pcs

TIS0071.02 I Optical fiber up to 100 m Installation and testing/commissioning of specified length of fiber optic cable or patch cord

Service

Installation of up to specified length of fiber optic cable or patch cord with fixing accessories, labels and connectors (if needed). Installation of protection tube, duct, trunk or conduit for the fiber optic cable. Cleaning of FO connectors and plugging on both ends according installation manual. Testing of the fiber optic cable run in its complete length. Terminating of the fiber optic cable run to the equipment or the ODF.

Excludes

Installation of fiber optic cable and its protection above specified length.

Page 44: TI service item description - nak-mci.ir

TI service item description Page 44

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Installation of FO Pigtail Cable 100% 1 pcs DNxxx Incl. fixing and labelling

100% 2 pcs DNxxx Pigtail splicing 2 Installation of FO Cable 100% 100 m DNxxx Incl. Protection, label, term,

test 0% 2 pcs DNxxx Connector mounting

3 Cleaning of FO connector 100% 2 pcs DNxxx Standard cleaning process 0% 2 pcs DNxxx Cleaning process for 10Gbs or higher speed FO with microscope

4 Commissioning of FO Cable 100% 100 m DNxxx Incl. Documentation

TIS0072.01 Test Call Making test call for each antenna after site on air

TIS0071.07 S General Fiber Optic Installation & Commissioning Installation and testing/commissioning of optical fiber up to 48 core per line meter in a route.

Service

Installation of up to specified length of fiber optic cable with fixing accessories, labels and connectors (if needed). Installation of protection tube or conduit for the fiber optic cable. Installation of fusion box/cassette (if needed) Cleaning of FO connectors and plugging on both ends according installation manual testing of the fiber optic cable run in its complete length. Terminating of the fiber optic cable run to the equipment or the ODF.

Bill of Quantities

Pos Category Occurrence Qnt Unit Component Remark 1 Installation of FO Pigtail Cable 100% 1 pcs DNxxx Incl. fixing and labelling

100% 2 pcs DNxxx Pigtail splicing 2 Installation of FO Cable 100% 20 m DNxxx Incl. Protection, label, term,

test 0% 2 pcs DNxxx Connector mounting

3 Cleaning of FO connector 100% 2 pcs DNxxx Standard cleaning process 0% 2 pcs DNxxx Cleaning process for 10Gbs or higher speed FO with microscope

4 Commissioning of FO Cable 100% 20 m DNxxx Incl. Documentation 5 Installation of Fusion box/Cassette 100% 1 pcs DNxxx

TIS0064.07 IC General Indoor Antenna System (SISO) Installation and commissioning of one indoor GSM antenna.

Service

Page 45: TI service item description - nak-mci.ir

TI service item description Page 45

Service of installation of one indoor antenna to prepare indoor coverage in a residential building, hospital, shopping center, official places, governmental, industrial, commercial building, hotel, airport … including provisioning and installation of mounting kit. Installation of 40m feeder cable per antenna including provisioning of all necessary fixing accessories. Provisioning and installation of required feeder protections such as every types of conduit, PVC pipe, duct or trunk. Installation of all passive DAS components such as jumper, combiner, splitter, tapper, and coupler including provisioning of all necessary fixing accessories and mounting kits. Provisioning and installation of standard labels for all DAS components.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 Feeder installation 100% 40 m

40m feeder per antenna should be measured totally for all installed antennas in one site.

2 Antenna Installation 100% 1 pcs Including mounting material

3 Conduit & Duct installation 100% 40 m Including material

4 Combiner/Coupler/Splitter/Tapper 100% 2 pcs

5 Mounting installation 100% 1 pcs

6 Jumper installation 100% 2 pcs

7 Connector installation 100% 4 pcs including sealing if needed

8 Site Survey 100% 0.1 pcs

TIS0064.09 IC General Indoor Antenna System (MIMO) Installation and commissioning of one indoor GSM antenna.

Service

Service of installation of one indoor antenna to prepare indoor coverage in a residential building, hospital, shopping center, official places, governmental, industrial, commercial building, hotel, airport … including provisioning and installation of mounting kit. Installation of 80m feeder cable per antenna including provisioning of all necessary fixing accessories. Provisioning and installation of required feeder protections such as every types of conduit, PVC pipe, duct or trunk. Installation of all passive DAS components such as jumper, combiner, splitter, tapper, and coupler including provisioning of all necessary fixing accessories and mounting kits. Installation of connectors and sealing connections if necessary. Provisioning and installation of standard labels for all DAS components.

Exclude

Page 46: TI service item description - nak-mci.ir

TI service item description Page 46

Provisioning and installation of cable tray

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 Feeder installation 100% 80 m

40m feeder per antenna should be measured totally for all installed antennas in one site.

2 Antenna Installation 100% 1 pcs Including mounting material

3 Conduit & Duct installation 100% 80 m Including material

4 Combiner/Coupler/Splitter/Tapper 100% 4 pcs

5 Mounting installation 100% 1 pcs

6 Jumper installation 100% 4 pcs

7 Connector installation 100% 8 pcs including sealing if needed

8 Site Survey 100% 0.1 pcs

TIS0062.05 Subway DAS Installation per antenna (SISO) Installation and commissioning of one indoor GSM antenna.

Service

Service of installation of one indoor antenna to prepare indoor coverage in a subway station including provisioning and installation of mounting kit. Installation of 40m feeder cable per antenna including provisioning of all necessary fixing accessories. Provisioning and installation of required feeder protections such as every types of conduit, PVC pipe, duct or trunk. Installation of all passive DAS components such as jumper, combiner, splitter, tapper, and coupler including provisioning of all necessary fixing accessories and mounting kits. Provisioning and installation of standard labels for all DAS components.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 Feeder installation 100% 40 m

40m feeder per antenna should be measured totally for all installed antennas in one site.

2 Antenna Installation 100% 1 pcs Including mounting material

3 Conduit & Duct installation 100% 40 m Including material

4 Combiner/Coupler/Splitter/Tapper 100% 2 pcs

5 Mounting installation 100% 1 pcs

Page 47: TI service item description - nak-mci.ir

TI service item description Page 47

6 Jumper installation 100% 2 pcs

7 Connector installation 100% 4 pcs including sealing if needed

8 Site Survey 100% 0.1 pcs

TIS0062.06 Subway DAS Installation per antenna (MIMO) Installation and commissioning of one indoor GSM antenna.

Service

Service of installation of one indoor antenna to prepare indoor coverage in a subway station including provisioning and installation of mounting kit. Installation of 80m feeder cable per antenna including provisioning of all necessary fixing accessories. Provisioning and installation of required feeder protections such as every types of conduit, PVC pipe, duct or trunk. Installation of all passive DAS components such as jumper, combiner, splitter, tapper, and coupler including provisioning of all necessary fixing accessories and mounting kits. Installation of connectors and sealing connections if necessary. Provisioning and installation of standard labels for all DAS components.

Exclude

Provisioning and installation of cable tray

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 Feeder installation 100% 80 m

40m feeder per antenna should be measured totally for all installed antennas in one site.

2 Antenna Installation 100% 1 pcs Including mounting material

3 Conduit & Duct installation 100% 80 m Including material

4 Combiner/Coupler/Splitter/Tapper 100% 4 pcs

5 Mounting installation 100% 1 pcs

6 Jumper installation 100% 4 pcs

7 Connector installation 100% 8 pcs including sealing if needed

8 Site Survey 100% 0.1 pcs

TIS0062.03 Tunnel DAS Installation per Antenna (SISO) Installation and commissioning of one indoor GSM antenna.

Page 48: TI service item description - nak-mci.ir

TI service item description Page 48

Service

Service of installation of one indoor antenna to prepare indoor coverage in a tunnel (subway, rural or urban) including provisioning and installation of mounting kit. Installation of 100m feeder cable per antenna including provisioning of all necessary fixing accessories. Provisioning and installation of required feeder protections such as every types of conduit, PVC pipe, duct or trunk. Installation of all passive DAS components such as jumper, combiner, splitter, tapper, and coupler including provisioning of all necessary fixing accessories and mounting kits. Provisioning and installation of standard labels for all DAS components.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 Feeder installation 100% 100 m

40m feeder per antenna should be measured totally for all installed antennas in one site.

2 Antenna Installation 100% 1 pcs Including mounting material

3 Conduit & Duct installation 100% 100 m Including material

4 Combiner/Coupler/Splitter/Tapper 100% 2 pcs

5 Mounting installation 100% 1 pcs

6 Jumper installation 100% 2 pcs

7 Connector installation 100% 4 pcs including sealing if needed

8 Site Survey 100% 0.1 pcs

TIS0062.07 Tunnel DAS Installation per antenna (MIMO) Installation and commissioning of one indoor GSM antenna.

Service

Service of installation of one indoor antenna to prepare indoor coverage in a tunnel (subway, rural or urban) including provisioning and installation of mounting kit. Installation of 200m feeder cable per antenna including provisioning of all necessary fixing accessories. Provisioning and installation of required feeder protections such as every types of conduit, PVC pipe, duct or trunk. Installation of all passive DAS components such as jumper, combiner, splitter, tapper, and coupler including provisioning of all necessary fixing accessories and mounting kits. Installation of connectors and sealing connections if necessary. Provisioning and installation of standard labels for all DAS components.

Exclude

Provisioning and installation of cable tray

Page 49: TI service item description - nak-mci.ir

TI service item description Page 49

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark

1 Feeder installation 100% 200 m

40m feeder per antenna should be measured totally for all installed antennas in one site.

2 Antenna Installation 100% 1 pcs Including mounting material

3 Conduit & Duct installation 100% 200 m Including material

4 Combiner/Coupler/Splitter/Tapper 100% 4 pcs

5 Mounting installation 100% 1 pcs

6 Jumper installation 100% 4 pcs

7 Connector installation 100% 8 pcs including sealing if needed

8 Site Survey 100% 0.1 pcs

TIS0055.02 Rem IBS Antenna

Removal and packing of an indoor GSM antenna Service

Disconnection of the feeder cable from the antenna Un-Installation of antenna with its own mounting kits Disconnection of the feeder cable from the antenna Termination of the feeder line to the antenna Un-installation and packaging of the Antenna Collecting of the removed items in a designated area at the site. Preparing asset sheet of uninstalled equipment Un-Installation of jumpers and feeder cables

Special cases and other requirements Water proofing of antenna ports are mandatory to avoid damaging antenna.

Bill of Quantities

Pos Category Occurrence Qnt Unit Remark 1 RF Antenna un-Installation 100% 1 pcs Inc. packing & labeling