THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max...
-
Upload
toby-rutter -
Category
Documents
-
view
212 -
download
0
Transcript of THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max...
![Page 1: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/1.jpg)
THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER
DESIGN IN DIFFERENT WAVELENGTH RANGES
Luca TeriacaMax Planck Institut für Sonnensystemforschung
![Page 2: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/2.jpg)
Expected throughput for spatiallyresolved observations.
A = 3.848×10−3 m2, area of the entrance aperture (primary mirror of D=7 cm).
S = 2.56×1010 m2, area of the solar surface imaged over one pixel at perihelion (160×160 km2) by EUS. Equivalent to 1″/pixel angular scale.
r = 3.2912×1010 m, Solar Orbiter–Sun distance at perihelion (0.22 AU).
RP(λ) = Reflectance of the primary SiC mirror.
RG(λ) = Reflectance of the concave variable line-spacing SiC grating (diffraction efficiency times SiC reflectance).
V(λ) = Slit vignetting. Here a 1” wide slit is assumed.
DQE(λ) = Detector quantum efficiency.
L(λ) = Spectral radiance (ph m–2 s–1 sr–1 nm–1). Both average quiet Sun and active region spectra are considered.
Δλ = Spectral resolution element. A value of 0.005 nm is assumed.
LDVRRr
SA
t
NQEGP2
![Page 3: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/3.jpg)
Reflectance of SiC mirrors
![Page 4: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/4.jpg)
Bare and KBr-coated MCPs
![Page 5: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/5.jpg)
Grating diffraction efficiency (SUMER)
λ (nm) efficiency (%) 77 17100 28122 28
efficiencies at higher orders are taken equal to that of the first order
![Page 6: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/6.jpg)
1165 – 1265 Å: Quiet Sun
![Page 7: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/7.jpg)
1165 – 1265 Å: Quiet Sun
![Page 8: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/8.jpg)
1165 – 1265 Å: Quiet Sun
![Page 9: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/9.jpg)
1165 – 1265 Å: Active Region
![Page 10: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/10.jpg)
1165 – 1265 Å: Active Region
![Page 11: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/11.jpg)
1165 – 1265 Å: Active Region
![Page 12: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/12.jpg)
950 – 1050 Å: Quiet Sun
C III
H I Ly γ H I Ly β O VI
Si XII Si XII
![Page 13: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/13.jpg)
950 – 1050 Å: Quiet Sun
C III
H I Ly γH I Ly β O VI
Si XII Si XII
![Page 14: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/14.jpg)
950 – 1050 Å: Active Region
Fe XVI
Si XII Si XII
![Page 15: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/15.jpg)
950 – 1050 Å: Active Region
Fe XVI
Si XII Si XII
![Page 16: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/16.jpg)
700 – 800 Å: Quiet Sun
O III O II O V Ne VIII O IV
N IV S V
Mg IX
![Page 17: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/17.jpg)
700 – 800 Å: Quiet Sun
O III O II O V Ne VIII O IV
N IV S V
Mg IX
![Page 18: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/18.jpg)
700 – 800 Å: Active Region
O III O II O V Ne VIII O IV
N IV S V
Fe XVI Mg IX
![Page 19: THROUGHPUT OF A NORMAL INCIDENCE SPECTROMETER DESIGN IN DIFFERENT WAVELENGTH RANGES Luca Teriaca Max Planck Institut für Sonnensystemforschung.](https://reader035.fdocuments.us/reader035/viewer/2022070307/551ac03955034656628b58d2/html5/thumbnails/19.jpg)
700 – 800 Å: Active Region
O III O II O V Ne VIII O IV
N IV S V
Fe XVI Mg IX