TIMBER DECKING- ALUMINIUM DOOR DECK THRESHOLD Appraisal No. 547 [2007] BRANZ Appraised APR 14 REV E New NTS DWG No: NURAPLY 3P DESCRIPTION: PREVIOUS DWG No: DATE: All applications to be installed by an authorised nuralite applicator. All materials to be applied in accordance with standard published installation instruction and product data sheet should be consulted at all times. This drawing is for comment & approval it must not be used for construction until authorised by the site specifier or other relevant technical expert. This detail drawing is to be used only as a part of the nuralite specification package. All drawings are subject to copyright. Unauthorised use is prohibited ?NURALITE WATERPROOFING Ltd. THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE NURALITE THE FLAT ROOF EXPERTS Nuralite Waterproofing Ltd. 53A Victoria Street, Onehunga, Auckland 1061, New Zealand TEL: (64) (9) 579-2046 FAX: (64) (9) 579-5136 email: [email protected] web: www.nuralite.co.nz SCALE: REVISION: PRODUCT: DPPT.A1

Transcript of THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS … · THIS DRAWING IS INDICATIVE ONLY AND BY NO...

Page 1: THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS … · THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE DATE: PREVIOUS DWG No: DESCRIPTION: NURAPLY 3P & NURAJACK DWG

TIMBER DECKING- ALUMINIUM DOOR DECK THRESHOLD

Appraisal No. 547 [2007]

BRANZ Appraised

APR 14REV E

NewNTS

DWG No:

NURAPLY 3P

DESCRIPTION:

PREVIOUS DWG No:

DATE:

All applications to be installed by an authorised nuralite applicator. All materials to

be applied in accordance with standard published installation instruction and product

data sheet should be consulted at all times. This drawing is for comment & approval it

must not be used for construction until authorised by the site specifier or other relevant

technical expert. This detail drawing is to be used only as a part of the nuralite specification

package.

All drawings are subject to copyright. Unauthorised use is prohibited

?NURALITE WATERPROOFING Ltd.

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE

NURALITE

THE FLAT ROOF EXPERTS

Nuralite Waterproofing Ltd.

53A Victoria Street, Onehunga,

Auckland 1061, New Zealand

TEL: (64) (9) 579-2046

FAX: (64) (9) 579-5136

email: [email protected]

web: www.nuralite.co.nz

SCALE:

REVISION:

PRODUCT:

DPPT.A1

Page 2: THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS … · THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE DATE: PREVIOUS DWG No: DESCRIPTION: NURAPLY 3P & NURAJACK DWG

Balustrade fixings

Fixing sealant detail asper E2/AS1 Clause 7.4.5

Glass balustrade

H3.2 treated structure

NURAPLY 3P double layer system.

NURAJACK or NURAPAD as specified.

Metal capEco Deck or selectedtimber deckingAluminium or treated timberjoist as specified

1:40 min. fall

"Allproof Sureflow" rainwateroutlet at lowest point - withoverflow placed elsewhere.

Downpipe.

H3.2 treated timber20mm min. angle fillet

1:40 min. fall

75m

m m

in

CCA treated H3.2 grade 21mm plywood laidto 1:40 min falls. glued & screwed to timberrafters, all edges supported on timber.

NURAPLY 3PBon Nurabond #10 adhesive

DPPT.B1

PRODUCT:

REVISION:

SCALE:

THE FLAT ROOF EXPERTS

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE

DATE:

PREVIOUS DWG No:

DESCRIPTION:

NURAPLY 3P & NURAJACK

DWG No:

NTS New

REV E APR 14

TIMBER DECKING- FRAMELESS BALUSTRADE

Page 3: THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS … · THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE DATE: PREVIOUS DWG No: DESCRIPTION: NURAPLY 3P & NURAJACK DWG

NURAJACK orNURAPAD as specified

NURAPLY 3P double layermembrane system

M8x150mm stainless steel coachscrews over stainless steel washer

over polymer washer

Double 190x45mm boundary joists

"Neoprene" washer

H3.2 treatedTimber fascia

Frosted toughened glass

1:40 min. fall

Selected gutter

Gutter bracket

"Unex" DKG bracket

M8x150mm stainless steel coachscrews over stainless steel

washer over polymer washerTimber fascia packer beyond

12mm Aluminum plate

50x50 Aluminum angle drip edge

Selected "Unex" Handrail post

Toughened Glass

Eco Deck or selected timber decking

Aluminium or treated timberjoist as specified

CCA treated H3.2 grade 21mm plywood laidto 1:40 min falls. glued & screwed to timberrafters, all edges supported on timber.

NURAPLY 3PB onNurabond #10 adhesive

DPPT.B2

PRODUCT:

REVISION:

SCALE:

THE FLAT ROOF EXPERTS

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE

DATE:

PREVIOUS DWG No:

DESCRIPTION:

NURAPLY 3P & NURAJACK

DWG No:

NTS New

Rev E NOV 12

TIMBER DECKING- UNEX BRACKET BALUSTRADE

Page 4: THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS … · THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE DATE: PREVIOUS DWG No: DESCRIPTION: NURAPLY 3P & NURAJACK DWG

75min

75mi

n

150m

m mi

n.

Metal overflashing.

Nuraply 3P turned into

chase. (20x20)

H3.2 treated timber

20mm min angle fillet.

12mm min. separation

NURAPLY 3P double

layer system.

Eco Deck or selected

timber decking

NURAJACK or NURAPADas specified

Aluminium or treated timber

joist as specified

1:40 min. fall

CCA treated H3.2 grade 21mm plywoodlaid to 1:40 min falls. glued & screwed totimber rafters, all edges supported ontimber.

NURAPLY 3PB on Nurabond #10 adhesive

Holdfast MS Fixall220 Sealant

DPPT.C1

PRODUCT:

REVISION:

SCALE:

THE FLAT ROOF EXPERTS

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE

DATE:

PREVIOUS DWG No:

DESCRIPTION:

NURAPLY 3P & NURAJACK

DWG No:

NTS New

Rev E APR 14

TIMBER DECKING- UPSTAND INTO CHASE

Page 5: THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS … · THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE DATE: PREVIOUS DWG No: DESCRIPTION: NURAPLY 3P & NURAJACK DWG

H3.2 treated timber

20mm min angle fillet

35mm

min

75mm

150m

m mi

n

Building paper to

lap over Nuraply 3P

Nuraply 3P upstand150mm min. height

Cladding to overlap

Nuraply 3P by 75mm

minimum.

12mm min. separation

NURAPLY 3P double

layer system.

Eco Deck or selected

timber decking

NURAJACK or NURAPAD

as specified

Aluminium or treated

timber joist as specified

1:40 min. fall

Termination bar to

fasten membrane

CCA treated H3.2 grade 21mm plywood laidto 1:40 min falls. glued & screwed to timberrafters, all edges supported on timber.

NURAPLY 3PBon Nurabond #10 adhesive

DPPT.C2

PRODUCT:

REVISION:

SCALE:

THE FLAT ROOF EXPERTS

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE

DATE:

PREVIOUS DWG No:

DESCRIPTION:

NURAPLY 3P & NURAJACK

DWG No:

NTS New

REV E APR 14

TIMBER DECKING- UPSTAND BEHIND CLADDING

Page 6: THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS … · THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE DATE: PREVIOUS DWG No: DESCRIPTION: NURAPLY 3P & NURAJACK DWG

H3.2 treated timber20mm min. angle fillet.

Metal overflashing.

H3.2 plywood upstandNuraply 3Pflashing strip

NURAPLY 3P double layersystem.

Eco Deck or selectedtimber decking.

Aluminium or treated timberjoist as specified

NURAJACK orNURAPAD as specified

70mm

min.

70 m

m mi

n.

5° min. slope

1:40 min. fall

Note:No min. parapet height required providedmembrane fully encapsulates the parapet.

CCA treated H3.2 grade 21mm plywood laidto 1:40 min falls. glued & screwed to timberrafters, all edges supported on timber.

NURAPLY 3PBon Nurabond #10adhesive

DPPT.D1

PRODUCT:

REVISION:

SCALE:

THE FLAT ROOF EXPERTS

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE

DATE:

PREVIOUS DWG No:

DESCRIPTION:

NURAPLY 3P & NURAJACK

DWG No:

NTS New

Rev E APR 14

TIMBER DECKING- PARAPET

Page 7: THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS … · THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE DATE: PREVIOUS DWG No: DESCRIPTION: NURAPLY 3P & NURAJACK DWG

Fixing sealant detail as perE2/AS1 Figure 7.4.5

Selectedbalustrade

NURAPLY 3P double layer system.

NURAJACK swivel head Screwjacks.Metal cap

Eco Deck or selectedtimber decking

Aluminium or treatedtimber joist as specified

1:40 min. fall

"Allproof Sureflow" rainwateroutlet. at lowest point - withoverflow placed elsewhere.

Downpipe

10

0m

m m

in

.

35

mm

m

in

.

12mm min. separation

1:40 min. fall

Note:Nurapads may be specified instead of Nurajacks.Tapered timber joist may be specified instead ofaluminium tube.

CCA treated H3.2 grade 21mm plywood laidto 1:40 min falls. Glued & screwed to timberrafters, all edges supported on timber

NURAPLY 3PBon Nurabond #10 adhesive

DPPT.E1

PRODUCT:

REVISION:

SCALE:

THE FLAT ROOF EXPERTS

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE

DATE:

PREVIOUS DWG No:

DESCRIPTION:

NURAPLY 3P & NURAJACK

DWG No:

NTS New

Rev E APR 14

TIMBER DECKING- OVERVIEW

Page 8: THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS … · THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE DATE: PREVIOUS DWG No: DESCRIPTION: NURAPLY 3P & NURAJACK DWG

1:40 min fall

Overflow below scupper to besame size or larger than downpipe

20mm nominal drainedand vented cavity

Metal or proprietaryrainwater head - fix andseal to face of building

Install flexible flashing tape adheringaround outlet and onto wall underlaybefore cladding installed

Cut proprietary outlet at angle andallow for recommended for foldeddrip edge for metal units

Seal all round between proprietaryoutlet & rainwater head to ensureno backflow of water behind

Nuraply 3P double layer systemSelected wall underlay

Selected wall cladding

Downpipe

Selected leaf guard

Nuraply 3P double layer systemNuralite aluminium scupper

sized as specified

1:40 min. fall

Recess in substrate

Stainless steel screw fixing

CCA treated H3.2 grade 21mm plywoodlaid to 1:40 min falls. glued & screwedto timber rafters, all edges supported ontimber.

NURAPLY 3PBon Nurabond #10 adhesive

NURAJACK orNURAPAD as specified

DPPT.F1

PRODUCT:

REVISION:

SCALE:

THE FLAT ROOF EXPERTS

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE

DATE:

PREVIOUS DWG No:

DESCRIPTION:

NURAPLY 3P & NURAJACK

DWG No:

NTS New

Rev E APR 14

TIMBER DECKING- SCUPPER

Page 9: THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS … · THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE DATE: PREVIOUS DWG No: DESCRIPTION: NURAPLY 3P & NURAJACK DWG

NURAPLY 3P double layer system

1:40 min. fall

Eco Deck or selectedtimber decking

Downpipe

"Allproof Sureflow" rainwateroutlet at lowest point - withoverflow placed elsewhere.

Rainwater outlet rebated into plywoodand screwed into place with S/S screws.

Nuraply 3P double layermembrane turned into outlet

NURAJACK orNURAPAD as specified

Aluminium or treated timberjoist as specified

1:40 min. fall

CCA treated H3.2 grade 21mm plywood laidto 1:40 min falls. glued & screwed to timberrafters, all edges supported on timber.

NURAPLY 3PB on Nurabond #10adhesive

DPPT.G1

PRODUCT:

REVISION:

SCALE:

THE FLAT ROOF EXPERTS

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE

DATE:

PREVIOUS DWG No:

DESCRIPTION:

NURAPLY 3P & NURAJACK

DWG No:

NTS New

Rev E APR 14

TIMBER DECKING- SMALL RAINWATER OUTLET