Thermally Broken Architectural Sliding Door · 06/08/2020  · 06-5001-11 Configuration will affect...

2
BALCONY DOORS YSD 600 T Thermally Broken Architectural Sliding Door Architectural Grade Sliding Door Product Options & Features The YSD 600 T is a thermally broken architectural (AW) rated sliding glass door designed to provide greater energy efficiency and occupant comfort. The engineering behind the design concept provides enhanced structural capabilities without the need to add reinforcing. This sliding door is designed to accept standard tempered 1” thick insulating units. All panels, fixed and operable, may be pre-glazed in the shop to take advantage of a controlled environment and less expensive shop labor. n Available configurations: OX, XO, OXO, OOX, XOO, OOOX, XOOO, OXOO, OOXO, XOOX & OXXO n AAMA/WDMA 101/I.S. 2-97/NAFS-02 w AW-75 Grade n Thermally broken by ThermaBond Plus ® (frame) and MegaTherm ® (panels) technology n Factory glazing and Screens n Standard heavy-duty hardware, including stainless steel tandem rollers & track cover for years of worry-free operation n Available with optional low-profile sill (Available in 2 & 3 panel configurations only) Values as low as 0.46 * Minimum 43frame & 62glass CRF U-Factor *Based on AAMA 507. Lower values may be achieved through futher simulation.

Transcript of Thermally Broken Architectural Sliding Door · 06/08/2020  · 06-5001-11 Configuration will affect...

Page 1: Thermally Broken Architectural Sliding Door · 06/08/2020  · 06-5001-11 Configuration will affect specifications. System Depth Glass Air Infiltration Water Infiltration Thermal

BALCONYDOORS

YSD 600 TThermally Broken Architectural Sliding Door

Architectural Grade Sliding Door

Product Options & Features

The YSD 600 T is a thermally broken architectural (AW) rated sliding glass door designed to provide greater energy efficiency and occupant comfort. The engineering behind the design concept provides enhanced structural capabilities without the need to add reinforcing. This sliding door is designed to accept standard tempered 1” thick insulating units. All panels, fixed and operable, may be pre-glazed in the shop to take advantage of a controlled environment and less expensive shop labor.

nAvailable configurations: OX, XO, OXO, OOX, XOO, OOOX, XOOO, OXOO, OOXO, XOOX & OXXO nAAMA/WDMA 101/I.S. 2-97/NAFS-02 w AW-75 GradenThermally broken by ThermaBond Plus® (frame) and MegaTherm® (panels) technologynFactory glazing and ScreensnStandard heavy-duty hardware, including stainless steel tandem rollers & track cover for years of worry-free operationnAvailable with optional low-profile sill (Available in 2 & 3 panel configurations only)

Values as low as 0.46*

Minimum 43frame & 62glassCRF

U-Factor

*Based on AAMA 507. Lower values may be achieved through futher simulation.

Page 2: Thermally Broken Architectural Sliding Door · 06/08/2020  · 06-5001-11 Configuration will affect specifications. System Depth Glass Air Infiltration Water Infiltration Thermal

©2020 YKK AP America Inc.270 Riverside Pkwy, Suite 100, Austell, GA 30168 Tel: 678-838-6000

SYSTEM SPECIFICATIONS YSD 600 T

06-5001-11

Configuration will affect specifications.

SystemDepth Glass Air

InfiltrationWater

InfiltrationThermal

PerformanceAcoustical

PerformanceForced EntryResistance

6”

1-3/16”Laminated IGU

with (C.O.G. U-factor: 0.29)

Sliding Doors:0.30 CFM/FT²@ 6.24 PSF

(299 Pa)

Static:20 psf (958 Pa)Low-Profile:12 psf (574 Pa)

U-factor: 0.51 BTU/HR•FT²•ºF*CRF: Minimum of 43 on frame**

Lam STC: 33Lam OITC: 30

Tested in accordanceand meets the

requirements ofPerformance Grade 10

Testing Standards ASTM E 283 ASTM E 331 & 547 *NFRC 100 & **AAMA 1503 ASTM E 90 & 1425 ASTM F 842 & TAS 202

Structural Performance AW Performance Grade 75

Available Finishes Factory Anodized (AAMA 612) and Organic Paints (AAMA 2604 & AAMA 2605)

Frame temperature comparison values based on 0º exterior, and 70º interior air temperatures.

Additional information including CAD details, CSI specifications, Test Reports and Installation instructions are available online at:www.ykkap.com/commercial/product/sliding-doors/ysd-600-t/

THERMAL IMAGING LOW PROFILE OPTION

2.6° 11.0° 19.4° 27.8° 36.2° 44.6° 53.0° 61.4° 69.8° F°

Temperature Scale

Standard Threshold Low Profile ThresholdStandard Threshold Low Profile Threshold*

Thermal Performance

1” IGU BTU/hr·ft2·°F

C.O.G U-Factor 0.30 0.28 0.26 0.24 0.22 0.20

Standard Threshold 0.53 0.52 0.50 0.49 0.48 0.46

Testing Standards AAMA 507

CRF

Frame Glass

43 62

AAMA 1503

*The Low Profile Threshold option is intended to integrate into designs that require low threshold access to balconies and terraces.