LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 2 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
INTENTIONALLY BLANK
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 3 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
CONTENTS
1. INTRODUCTION ...........................................................................................................................................5
2. DOCUMENTS................................................................................................................................................5 2.1 Applicable Documents............................................................................................................................5
3. SUMMARY OF REQUIRED HARDWARE ....................................................................................................5
4. LOCATION AND TYPES OF PLATFORM MLI .............................................................................................6
5. OVERVIEW OF SCM MLI LOCATIONS .......................................................................................................8 5.1 General Overview...................................................................................................................................8 5.2 Lower Floor Overview ............................................................................................................................9 5.3 Lower Cylinder Overview .......................................................................................................................9 5.4 External Closure Panels Overview.......................................................................................................10 5.5 Unit Specific MLI Overview ..................................................................................................................13 5.6 Flight Model Heaters ............................................................................................................................16 5.7 Test Heaters .........................................................................................................................................18 5.8 Thermal Interface Materials..................................................................................................................19 5.9 Thermistors...........................................................................................................................................19 5.10 Thermocouples...................................................................................................................................22
TABLES
Table 1: Deliverable Hardware Quantities.........................................................................................................5 Table 2: List of SCM MLI Blankets ....................................................................................................................7 Table 2: List of SCM Heaters ..........................................................................................................................18 Table 2: List of SCM Interface Materials .........................................................................................................19 Table 2: List of SCM Thermistors ....................................................................................................................22
FIGURES Figure 1: SCM Spacecraft View from +X+Y side ..............................................................................................8 Figure 2: SCM Spacecraft View from –X-Y side ...............................................................................................8 Figure 3: SCM Spacecraft View from -Z side ....................................................................................................9 Figure 4: SCM Lower Cylinder MLI ...................................................................................................................9 Figure 5: Closure Panel 1 (+X)........................................................................................................................10 Figure 6: Closure Panel 2 (+X+Y) ...................................................................................................................10 Figure 7: Closure Panel 3 (+Y)........................................................................................................................10 Figure 8: Closure Panel 4 (-X+Y) ....................................................................................................................11 Figure 9: Closure Panel 5 (-X).........................................................................................................................11 Figure 10: Closure Panel 6 (-X-Y) ...................................................................................................................11 Figure 11: Closure Panel 7 (-Y).......................................................................................................................12 Figure 12: Closure Panel 8 (+X-Y) ..................................................................................................................12 Figure 13: Battery MLI .....................................................................................................................................13 Figure 14: Sun Sensor MLI (1 of 3) .................................................................................................................13 Figure 15: AST MLI..........................................................................................................................................13 Figure 16: MGA MLI ........................................................................................................................................14 Figure 17: MGA MLI ........................................................................................................................................14 Figure 17: FEEP Cluster MLI...........................................................................................................................14
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 4 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
Figure 18: Spacecraft – Solar Array Gap MLI .................................................................................................15
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 5 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
1. INTRODUCTION
This document provides an overview of the thermal hardware items required for the LISA PathFinder SCM spacecraft.
2. DOCUMENTS
2.1 Applicable Documents
a S2.ASU.SOW.2028 LPF SCM Thermal Hardware SOW
b S2.ASU.RS.2060 SCM Thermal Hardware Requirement Specification
c S2.ASU.ICD.2002 SCM Mechanical Interface Configuration Document
3. SUMMARY OF REQUIRED HARDWARE
The following is a summary of the total number of items required from the SCM thermal hardware:
Item Quantity FM Heaters 300 Test Heaters 50 Unit Interface Thermal Filler 28 Low Conductivity Washers 32 External MLI (including spares) 50 Thermal Test MLI 5 External MLI Post Thermal Test 8 Unit Specific MLI 11 Thermistors 100 Thermocouples 330
Table 1: Deliverable Hardware Quantities
The following section contain more comprehensive tables defining the deliverable hardware.
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 6 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
4. LOCATION AND TYPES OF PLATFORM MLI
Name Location Enveloping Size (1) (mm) Type
MLI replacement
After Test Particularity
SCMLI_001 Lower Closure +Y inner 820 x 440 (TBC) S/C External (*) Several cut-outs
SCMLI_002 Lower Closure -Y inner 820 x 440 (TBC) S/C External (*) Several cut-outs
SCMLI_003 Lower Cylinder Outer +X 90 x 1300 (TBC) S/C External √
SCMLI_004 Lower Cylinder Outer -X 90 x 1300 (TBC) S/C External √
SCMLI_005 Lower Cylinder Inner -X 220 x 1300 (TBC) S/C External √
SCMLI_006 Lower Cylinder Inner +X 220 x 1300 (TBC) S/C External √
SCMLI_007 LCA Cage Base radius 400 (TBC) S/C External (*)
SCMLI_010 Lower Closure +X outer 600 x 300 (TBC) S/C External (*)
SCMLI_020 Lower Closure +X+Y outer 60 x 325 (TBC) S/C External (*)
SCMLI_030 Lower Closure +Y outer 1130 x 700 (TBC) S/C External (*)
SCMLI_040 Lower Closure -X-Y outer 670 x 420 (TBC) S/C External (*)
SCMLI_050 Lower Closure MGA 500 x 290 (TBC) S/C External (*)
SCMLI_060 Lower Closure -Y outer 540 x 930 (TBC) S/C External (*)
SCMLI_101 Panel +X 310 x 160 (TBC) S/C External √ Radiator trimming
SCMLI_102 Panel +X 720 x 310 (TBC) S/C External (*)
SCMLI_103 Panel +X 310 x 135 (TBC) S/C External (*)
SCMLI_201 Panel +X+Y 50 x 680 (TBC) S/C External (*)
SCMLI_202 Panel +X+Y 720 x 130 (TBC) S/C External (*)
SCMLI_203 Panel +X+Y 80 x 680 (TBC) S/C External (*)
SCMLI_301 Panel +Y 50 x 910 (TBC) S/C External (*)
SCMLI_302 Panel +Y 720 x 170 (TBC) S/C External (*)
SCMLI_303 Panel +Y Electrical Connector 190 x 910 (TBC) S/C External √ Removable blanket
SCMLI_304 Panel +Y Trim Blanket 480 x 300 (TBC) S/C External (*) Radiator trimming
SCMLI_401 Panel -X+Y 360 x 680 (TBC) S/C External (*)
SCMLI_402 Panel -X+Y 720 x 310 (TBC) S/C External (*)
SCMLI_403 Panel -X+Y 320 x 480 (TBC) S/C External (*)
SCMLI_404 Panel -X+Y 50 x 680 (TBC) S/C External (*)
SCMLI_501 Panel -X 310 x 160 (TBC) S/C External (*) Radiator trimming
SCMLI_502 Panel -X 720 x 400 (TBC) S/C External (*)
SCMLI_503 Panel -X 310 x 135 (TBC) S/C External (*)
SCMLI_601 Panel -X-Y 50 x 590 (TBC) S/C External (*)
SCMLI_602 Panel -X-Y 720 x 180 (TBC) S/C External (*)
SCMLI_603 Panel -X-Y Electrical Connector 230 x 590 (TBC) S/C External √ Removable blanket
SCMLI_604 Panel -X-Y 620 x 170 (TBC) S/C External (*) Radiator trimming
SCMLI_701 Panel -Y 720 x 400 (TBC) S/C External (*)
SCMLI_702 Panel -Y 360 x 450 (TBC) S/C External (*)
SCMLI_703 Panel -Y 720 x 170 (TBC) S/C External (*)
SCMLI_704 Panel -Y 60 x 450 (TBC) S/C External (*)
SCMLI_801 Panel +X-Y 470 x 640 (TBC) S/C External (*) Radiator trimming
SCMLI_802 Panel +X-Y 720 x 310 (TBC) S/C External (*)
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 7 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
Name Location Enveloping Size (1) (mm) Type
MLI replacement
After Test Particularity
SCMLI_803 Panel +X-Y Electrical Connector 220 x 640 (TBC) S/C External √ Radiator trimming Removable blanket
SCMLI_901 Battery 450 x 360 (TBC) Unit Specific (**)
SCMLI_911 Sun Sensor 1 Upper 190 x 180 (TBC) Unit Specific (**)
SCMLI_912 Sun Sensor 1 Lower 200 x 150 (TBC) Unit Specific (**)
SCMLI_913 Sun Sensor 2 Upper 190 x 180 (TBC) Unit Specific (**)
SCMLI_914 Sun Sensor 2 Lower 200 x 150 (TBC) Unit Specific (**)
SCMLI_915 Sun Sensor 3 Upper 190 x 180 (TBC) Unit Specific (**)
SCMLI_916 Sun Sensor 3 Lower 200 x 150 (TBC) Unit Specific (**)
SCMLI_921 AST 1 & 2 880 x 650 (TBC) Unit Specific (**)
SCMLI_931 MGA Base 290 x 170 (TBC) Unit Specific (**)
SCMLI_941 LGA 1 Bracket 280 x 120 (TBC) (2) Unit Specific (**)
SCMLI_942 LGA 2 Bracket 280 x 120 (TBC) (2) Unit Specific (**)
SCMLI_951 FEEP Cluster 1 520x 520 (TBC) S/C External (**)
SCMLI_952 FEEP Cluster 2 520x 520 (TBC) S/C External (**)
SCMLI_953 FEEP Cluster 3 520x 520 (TBC) S/C External (**)
SCMLI_991 Spacecraft - Solar Array Gap +X+Y 100 x 1250 (TBC) S/C External (*)
SCMLI_992 Spacecraft - Solar Array Gap -X+Y 100 x 1850 (TBC) S/C External (*)
SCMLI_993 Spacecraft - Solar Array Gap -X-Y 100 x 1250 (TBC) S/C External (*)
SCMLI_994 Spacecraft - Solar Array Gap +X-Y 100 x 1850 (TBC) S/C External (*)
TTMLI_01 Test Blanket to cover test harness 3000 x 500 (TBC) Thermal Test n/a
TTMLI_02 Test Blanket to cover test harness 3000 x 500 (TBC) Thermal Test n/a
TTMLI_03 Test Blanket to cover test harness 3000 x 500 (TBC) Thermal Test n/a
TTMLI_04 Test Blanket to cover test harness 3000 x 500 (TBC) Thermal Test n/a
TTMLI_05 Test Blanket to cover test harness 3000 x 500 (TBC) Thermal Test n/a
SCMLI_998 Spare TBD TBD -
SCMLI_999 Spare TBD TBD -
Total 10.1 m2 (TBC) (3) 66 8
Table 2: List of SCM MLI Blankets
Note:
The number of blankets per item is estimated. The MLI supplier is responsible to review and reassess the number of blankets necessary per item.
(1) Dimensions represent a rectangle that envelops the item area, and is estimated and will be subject to changes. The blanket area does not take into account the overlapping and borders
(2) Doesn’t include area required to insulate antenna coax cable
(3) Total area of blanket installed on spacecraft. Total does not include test blankets.
(*) MLI blanket assumed to be removable. There is therefore no need to replace them
(**) MLI blanket assumed not to be damaged during the FM tests. There is therefore no need to replace them.
The supplier shall be able to use blankets from other panels (lower closure, Closure panels) to overlap the edges of the panels as he sees fit. In that case, the overlapping concept shall be described and the concept of removable blankets shall be considered.
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 8 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
5. OVERVIEW OF SCM MLI LOCATIONS
5.1 General Overview
Figure 1: SCM Spacecraft View from +X+Y side
Figure 2: SCM Spacecraft View from –X-Y side
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 9 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
5.2 Lower Floor Overview
Figure 3: SCM Spacecraft View from -Z side
5.3 Lower Cylinder Overview
Figure 4: SCM Lower Cylinder MLI
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 10 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
5.4 External Closure Panels Overview
Figure 5: Closure Panel 1 (+X)
Figure 6: Closure Panel 2 (+X+Y)
Figure 7: Closure Panel 3 (+Y)
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 11 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
Figure 8: Closure Panel 4 (-X+Y)
Figure 9: Closure Panel 5 (-X)
Figure 10: Closure Panel 6 (-X-Y)
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 12 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
Figure 11: Closure Panel 7 (-Y)
Figure 12: Closure Panel 8 (+X-Y)
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 13 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
5.5 Unit Specific MLI Overview
Figure 13: Battery MLI
Figure 14: Sun Sensor MLI (1 of 3)
Figure 15: AST MLI
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 14 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
Figure 16: MGA MLI
Figure 17: MGA MLI
Figure 18: FEEP Cluster MLI
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 15 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
Figure 19: Spacecraft – Solar Array Gap MLI
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 16 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
5.6 Flight Model Heaters
These heaters will be of the etched-foil type, encapsulated in Kapton. Most heaters have multiple elements, with the actual element that is used selected after spacecraft installation of the mat. This is to allow the heater dissipation to be tuned to the unit requirement post thermal test. The resistance provided below are the nominal, with the tuning provided by additional elements whose resistance is above and below the nominal. The redundancy is provided by a second separate heater mat. All heater elements shall not induce a magnetic field when operating. (non-induction type)
Heater Circuit Unit Heater Number
(Nominal) Heater Number
(Redundant) Heater Number
(Spare) Power
(@24V) (W) Heater Resistance
(Ohms) Dimensions
(mm) LCA Structure I/F 1 TH-HTP001 TH-HTR001 TH-HTS001 0.5 72.0 (TBC) 10 x 30 (TBC)LCA Structure I/F 2 TH-HTP002 TH-HTR002 TH-HTS002 0.5 72.0 (TBC) 10 x 30 (TBC)LCA Structure I/F 3 TH-HTP003 TH-HTR003 TH-HTS003 0.5 72.0 (TBC) 10 x 30 (TBC)
HC1
LCA Structure I/F 4 TH-HTP004 TH-HTR004 TH-HTS004 0.5 72.0 (TBC) 10 x 30 (TBC)TH-HTP005 TH-HTR005 TH-HTS005 1.375 104.7 (TBC) 10 x 20 (TBC)
HC2 AST 1 Bracket I/F Ring TH-HTP006 TH-HTR006 TH-HTS006 1.375 104.7 (TBC) 10 x 20 (TBC)
TH-HTP007 TH-HTR007 TH-HTS007 1.375 104.7 (TBC) 10 x 20 (TBC)HC3 AST 2 Bracket I/F
Ring TH-HTP008 TH-HTR008 TH-HTS008 1.375 104.7 (TBC) 10 x 20 (TBC)
Colloid 1 Nozzle 1 TH-HTP009 TH-HTR009 TH-HTS009 0.9 40.0 (TBC) 200 x 10 (TBC)
Colloid 1 Nozzle 2 TH-HTP010 TH-HTR010 TH-HTS010 0.9 40.0 (TBC) 200 x 10 (TBC)
Colloid 1 Nozzle 3 TH-HTP011 TH-HTR011 TH-HTS011 0.9 40.0 (TBC) 200 x 10 (TBC)
HC4
Colloid 1 Nozzle 4 TH-HTP012 TH-HTR012 TH-HTS012 0.9 40.0 (TBC) 200 x 10 (TBC)
Colloid 2 Nozzle 1 TH-HTP013 TH-HTR013 TH-HTS013 0.9 40.0 (TBC) 200 x 10 (TBC)
Colloid 2 Nozzle 2 TH-HTP014 TH-HTR014 TH-HTS014 0.9 40.0 (TBC) 200 x 10 (TBC)
Colloid 2 Nozzle 3 TH-HTP015 TH-HTR015 TH-HTS015 0.9 40.0 (TBC) 200 x 10 (TBC)
HC5
Colloid 2 Nozzle 4 TH-HTP016 TH-HTR016 TH-HTS016 0.9 40.0 (TBC) 200 x 10 (TBC)
Colloid 1 Flange 1 TH-HTP017 TH-HTR017 TH-HTS017 3.5 10.3 (TBC) 10 x 70 (TBC)Colloid 1 Flange 2 TH-HTP018 TH-HTR018 TH-HTS018 3.5 10.3 (TBC) 10 x 70 (TBC)Colloid 1 Flange 3 TH-HTP019 TH-HTR019 TH-HTS019 3.5 10.3 (TBC) 10 x 70 (TBC)
HC6
Colloid 1 Flange 4 TH-HTP020 TH-HTR020 TH-HTS020 3.5 10.3 (TBC) 10 x 70 (TBC)Colloid 2 Flange 1 TH-HTP021 TH-HTR021 TH-HTS021 3.5 10.3 (TBC) 10 x 70 (TBC)Colloid 2 Flange 2 TH-HTP022 TH-HTR022 TH-HTS022 3.5 10.3 (TBC) 10 x 70 (TBC)Colloid 2 Flange 3 TH-HTP023 TH-HTR023 TH-HTS023 3.5 10.3 (TBC) 10 x 70 (TBC)
HC7
Colloid 2 Flange 4 TH-HTP024 TH-HTR024 TH-HTS024 3.5 10.3 (TBC) 10 x 70 (TBC)
TH-HTP025 TH-HTR025 TH-HTS025 11.5 3.1 (TBC) 20 x 150 (TBC) Colloid 1 Flange
TH-HTP026 TH-HTR026 TH-HTS026 11.5 3.1 (TBC) 20 x 150 (TBC)
TH-HTP027 TH-HTR027 TH-HTS027 11.5 3.1 (TBC) 20 x 150 (TBC)
HC8
Colloid 2 Flange TH-HTP028 TH-HTR028 TH-HTS028 11.5 3.1 (TBC) 20 x 150
(TBC) TH-HTP029 TH-HTR029 TH-HTS029 1.9 12.9 (TBC) 15 x 70 (TBC)
RLU panel I/F TH-HTP030 TH-HTR030 TH-HTS030 1.9 12.9 (TBC) 15 x 70 (TBC)TH-HTP031 TH-HTR031 TH-HTS031 2.7 18.4 (TBC) 50 x 10 (TBC)
HC9 LMU panel I/F
TH-HTP032 TH-HTR032 TH-HTS032 2.7 18.4 (TBC) 50 x 10 (TBC)HC10 RLU panel I/F TH-HTP033 TH-HTR033 TH-HTS033 0.45 320.0 (TBC) 10 x 30 (TBC)
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 17 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
Heater Circuit Unit Heater Number
(Nominal) Heater Number
(Redundant) Heater Number
(Spare) Power
(@24V) (W) Heater Resistance
(Ohms) Dimensions
(mm) TH-HTP034 TH-HTR034 TH-HTS034 0.45 320.0 (TBC) 10 x 30 (TBC)
TH-HTP035 TH-HTR035 TH-HTS035 0.9 640.0 (TBC) 10 x 30 (TBC)HC11 RLU panel I/F
TH-HTP036 TH-HTR036 TH-HTS036 0.9 640.0 (TBC) 10 x 30 (TBC)TH-HTP037 TH-HTR037 TH-HTS037 0.23 274.3 (TBC) 10 x 20 (TBC)TH-HTP038 TH-HTR038 TH-HTS038 0.23 274.3 (TBC) 10 x 20 (TBC)HC12 LMU panel I/F
TH-HTP039 TH-HTR039 TH-HTS039 0.233333333 274.3 (TBC) 10 x 20 (TBC)TH-HTP040 TH-HTR040 TH-HTS040 0.466666667 548.6 (TBC) 10 x 20 (TBC)TH-HTP041 TH-HTR041 TH-HTS041 0.466666667 548.6 (TBC) 10 x 20 (TBC)HC13 LMU panel I/F
TH-HTP042 TH-HTR042 TH-HTS042 0.466666667 548.6 (TBC) 10 x 20 (TBC)RLU panel I/F TH-HTP043 TH-HTR043 TH-HTS043 23 13.8 (TBC) 70 x 40 (TBC)
HC14 LMU panel I/F TH-HTP044 TH-HTR044 TH-HTS044 8 4.8 (TBC) 20 x 70 (TBC)LTP FEE SSU TH-HTP045 TH-HTR045 TH-HTS045 3 3.0 (TBC) 10 x 60 (TBC)LTP FEE PCU TH-HTP046 TH-HTR046 TH-HTS046 5 5.0 (TBC) 10 x 60 (TBC)
TH-HTP047 TH-HTR047 TH-HTS047 5 5.0 (TBC) 20 x 70 (TBC)LTP DMU
TH-HTP048 TH-HTR048 TH-HTS048 5 5.0 (TBC) 20 x 70 (TBC)TH-HTP049 TH-HTR049 TH-HTS049 3 3.0 (TBC) 40 x 20 (TBC)
HC15
LTP CCU TH-HTP050 TH-HTR050 TH-HTS050 3 3.0 (TBC) 40 x 20 (TBC)
FEEP Cluster 1 Panel I/F 1 TH-HTP051 TH-HTR051 TH-HTS051 2.25 16.0 (TBC) 10 x 60 (TBC)
FEEP Cluster 1 Panel I/F 2 TH-HTP052 TH-HTR052 TH-HTS052 2.25 16.0 (TBC) 10 x 60 (TBC)
FEEP Cluster 1 Panel I/F 3 TH-HTP053 TH-HTR053 TH-HTS053 2.25 16.0 (TBC) 10 x 60 (TBC)
HC16
FEEP Cluster 1 Panel I/F 4 TH-HTP054 TH-HTR054 TH-HTS054 2.25 16.0 (TBC) 10 x 60 (TBC)
TH-HTP055 TH-HTR055 TH-HTS055 3.5 41.1 (TBC) 20 x 100 (TBC) HC17 SAU 1
TH-HTP056 TH-HTR056 TH-HTS056 3.5 41.1 (TBC) 20 x 100 (TBC)
TH-HTP057 TH-HTR057 TH-HTS057 5 28.8 (TBC) 20 x 100 (TBC) HC18 SAU 2
TH-HTP058 TH-HTR058 TH-HTS058 5 28.8 (TBC) 20 x 100 (TBC)
Umbilical 1 TH-HTP059 TH-HTR059 TH-HTS059 2 2.7 (TBC) 30 x 10 (TBC)Umbilical 2 TH-HTP060 TH-HTR060 TH-HTS060 1.5 2.1 (TBC) 30 x 10 (TBC)Umbilical 3 TH-HTP061 TH-HTR061 TH-HTS061 1.5 2.1 (TBC) 30 x 10 (TBC)Umbilical 4 TH-HTP062 TH-HTR062 TH-HTS062 2 2.7 (TBC) 30 x 10 (TBC)Umbilical 5 TH-HTP063 TH-HTR063 TH-HTS063 1.5 2.1 (TBC) 30 x 10 (TBC)Umbilical 6 TH-HTP064 TH-HTR064 TH-HTS064 2 2.7 (TBC) 30 x 10 (TBC)Umbilical 7 TH-HTP065 TH-HTR065 TH-HTS065 1.5 2.1 (TBC) 30 x 10 (TBC)Umbilical 8 TH-HTP066 TH-HTR066 TH-HTS066 1.5 2.1 (TBC) 30 x 10 (TBC)Umbilical 9 TH-HTP067 TH-HTR067 TH-HTS067 1.5 2.1 (TBC) 30 x 10 (TBC)Umbilical 10 TH-HTP068 TH-HTR068 TH-HTS068 2 2.7 (TBC) 30 x 10 (TBC)Umbilical 11 TH-HTP069 TH-HTR069 TH-HTS069 1.5 2.1 (TBC) 30 x 10 (TBC)
HC19
Umbilical 12 TH-HTP070 TH-HTR070 TH-HTS070 2 2.7 (TBC) 30 x 10 (TBC)Neutraliser 1 Panel I/F TH-HTP071 TH-HTR071 TH-HTS071 2.75 23.3 (TBC) 10 x 80 (TBC)
Neutraliser 2 Panel I/F TH-HTP072 TH-HTR072 TH-HTS072 2.75 23.3 (TBC) 10 x 80 (TBC)HC20
Neutraliser 3 Panel I/F TH-HTP073 TH-HTR073 TH-HTS073 2.75 23.3 (TBC) 10 x 80 (TBC)
TH-HTP074 TH-HTR074 TH-HTS074 4 7.1 (TBC) 10 x 70 (TBC)HC21 LPT LCU
TH-HTP075 TH-HTR075 TH-HTS075 4 7.1 (TBC) 10 x 70 (TBC)
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 18 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
Heater Circuit Unit Heater Number
(Nominal) Heater Number
(Redundant) Heater Number
(Spare) Power
(@24V) (W) Heater Resistance
(Ohms) Dimensions
(mm) LPT PMU TH-HTP076 TH-HTR076 TH-HTS076 7 12.4 (TBC) 10 x 90 (TBC)LCA Structure I/F 1 TH-HTP077 TH-HTR077 TH-HTS077 0.75 1.3 (TBC) 10 x 10 (TBC)LCA Structure I/F 2 TH-HTP078 TH-HTR078 TH-HTS078 0.75 1.3 (TBC) 10 x 10 (TBC)LCA Structure I/F 3 TH-HTP079 TH-HTR079 TH-HTS079 0.75 1.3 (TBC) 10 x 10 (TBC)
LCA Structure I/F 4 TH-HTP080 TH-HTR080 TH-HTS080 0.75 1.3 (TBC) 10 x 10 (TBC)TH-HTP081 TH-HTR081 TH-HTS081 4.5 32.0 (TBC) 10 x 60 (TBC)
HC22 Battery TH-HTP082 TH-HTR082 TH-HTS082 4.5 32.0 (TBC) 10 x 60 (TBC)
HC23 PCDU TH-HTP083 TH-HTR083 TH-HTS083 5 115.2 (TBC) 10 x 65 (TBC)
FEEP PCU 1 TH-HTP084 TH-HTR084 TH-HTS084 11 1.6 (TBC) 10 x 140 (TBC)
FEEP Cluster 1 TH-HTP085 TH-HTR085 TH-HTS085 4 0.6 (TBC) 10 x 50 (TBC)FEEP Cluster 1 LOM TH-HTP086 TH-HTR086 TH-HTS086 10 1.5 (TBC) 50 x 25 (TBC)FEEP PCU 2 TH-HTP087 TH-HTR087 TH-HTS087 4 0.6 (TBC) 10 x 50 (TBC)FEEP Cluster 2 TH-HTP088 TH-HTR088 TH-HTS088 4 0.6 (TBC) 10 x 50 (TBC)FEEP Cluster 2 LOM TH-HTP089 TH-HTR089 TH-HTS089 10 1.5 (TBC) 50 x 25 (TBC)FEEP PCU 3 TH-HTP090 TH-HTR090 TH-HTS090 6 0.9 (TBC) 10 x 75 (TBC)FEEP Cluster 3 TH-HTP091 TH-HTR091 TH-HTS091 4 0.6 (TBC) 10 x 50 (TBC)
HC24
FEEP Cluster 3 LOM TH-HTP092 TH-HTR092 TH-HTS092 10 1.5 (TBC) 50 x 25 (TBC)TBC Spare 1 TH-HTP093 TH-HTR093 TH-HTS093 TBD TBD TBD TBC Spare 2 TH-HTP094 TH-HTR094 TH-HTS094 TBD TBD TBD TBC Spare 3 TH-HTP095 TH-HTR095 TH-HTS095 TBD TBD TBD TBC Spare 4 TH-HTP096 TH-HTR096 TH-HTS096 TBD TBD TBD TBC Spare 5 TH-HTP097 TH-HTR097 TH-HTS097 TBD TBD TBD TBC Spare 6 TH-HTP098 TH-HTR098 TH-HTS098 TBD TBD TBD TBC Spare 7 TH-HTP099 TH-HTR099 TH-HTS099 TBD TBD TBD TBC Spare 8 TH-HTP100 TH-HTR100 TH-HTS100 TBD TBD TBD
Each heater requires a spare for installation. Heater resistances currently TBD. To be supplier at supplier Kick-Off.
Table 3: List of SCM Heaters
5.7 Test Heaters
The location and resistance of the SCM thermal test heaters are TBC, however the test facility can support up to 50.
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 19 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
5.8 Thermal Interface Materials
A total of 1.02m2 (TBC) of conductive filler gasket is necessary for the units that require a high conductive coupling to the structure. In addition a total of 24 thermally isolating washers are required for the antennas that shall be conductively isolated from the spacecraft.
Sub-System Unit
Interface Dimensions (mm)
TBC Structure Interface
Post Thermal Test Replacement
PCDU 335 x 285 Conductive Filler X OBC 320 x 300 Conductive Filler X Transponder 200 x 150 Conductive Filler X MGA - 8 Washers (5mm thick)
Power, Computer,
TT&C
LGA (x2) - 8 Washers (5mm thick) AOCS STE (DPU) (x2) 245 x 165 Conductive Filler X
Sun Sensors (x3) - 4 Washers (5mm thick) FEEP PCU (x3) 240 x 165 Conductive Filler X EPDP PCU 145 x 115 Conductive Filler X
CCU 250 x 250 Conductive Filler X DMU 315 x 210 Conductive Filler X FEE SAU (x2) 340 x 310 Conductive Filler X LCU 235 x 175 Conductive Filler X PMU 265 x 195 Conductive Filler X
LTP
ULU 340 x 150 Conductive Filler X
Colloid Thruster (x2) 300 x 300 (250 x 250 hole) Conductive Filler X
DRS IAU 230 x 210 Conductive Filler X
Table 4: List of SCM Interface Materials
5.9 Thermistors
The SCM design provides for a total of 90 thermistors for temperature monitoring and active heater control. The allocation of these thermistors is presented below. In addition to the following, 10 Yellowspring (10kohm, YSI) thermistors are required as spare for installation, requiring a total of 100 thermistors to be delivered.
Function (TBC) Thermistor
Number Thermistor Type Location (TBC) Monitoring
TMV Heater Control
Fine Temperature Measurement
Windowing
TH-TCS001 Yellowspring (10kohm, YSI) LTP LCA Cage +X x x TH-TCS002 Yellowspring (10kohm, YSI) LTP LCA Cage +Y x x TH-TCS003 Yellowspring (10kohm, YSI) LTP LCA Cage +Z x x TH-TCS004 Yellowspring (10kohm, YSI) LTP LCA Cage -X x x TH-TCS005 Yellowspring (10kohm, YSI) LTP LCA Cage -Y x x
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 20 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
Function (TBC) Thermistor
Number Thermistor Type Location (TBC) Monitoring
TMV Heater Control
Fine Temperature Measurement
Windowing
TH-TCS006 Yellowspring (10kohm, YSI) LTP LCA Cage -Z x x TH-TCS007 Yellowspring (10kohm, YSI) LTP IS FEE SAU +X x x TH-TCS008 Yellowspring (10kohm, YSI) LTP IS FEE SAU -X x x TH-TCS009 Yellowspring (10kohm, YSI) LTP LAB x x TH-TCS010 Yellowspring (10kohm, YSI) LTP PMU x x TH-TCS011 Yellowspring (10kohm, YSI) LTP LMU x x x TH-TCS012 Yellowspring (10kohm, YSI) LTP RLU x x x TH-TCS013 Yellowspring (10kohm, YSI) LTP LMU x TH-TCS014 Yellowspring (10kohm, YSI) LTP LMU x TH-TCS015 Yellowspring (10kohm, YSI) LTP RLU x TH-TCS016 Yellowspring (10kohm, YSI) LTP RLU x TH-TCS017 Yellowspring (10kohm, YSI) AST +X x x TH-TCS018 Yellowspring (10kohm, YSI) AST +X x TH-TCS019 Yellowspring (10kohm, YSI) AST +X x TH-TCS020 Yellowspring (10kohm, YSI) AST -X x x TH-TCS021 Yellowspring (10kohm, YSI) AST -X x TH-TCS022 Yellowspring (10kohm, YSI) AST -X x TH-TCS023 Yellowspring (10kohm, YSI) Battery x x TH-TCS024 Yellowspring (10kohm, YSI) Battery x TH-TCS025 Yellowspring (10kohm, YSI) Battery x TH-TCS026 Yellowspring (10kohm, YSI) DRS Colloid Thruster +X x x TH-TCS027 Yellowspring (10kohm, YSI) DRS Colloid Thruster +X x TH-TCS028 Yellowspring (10kohm, YSI) DRS Colloid Thruster +X x TH-TCS029 Yellowspring (10kohm, YSI) DRS Colloid Thruster -X x x TH-TCS030 Yellowspring (10kohm, YSI) DRS Colloid Thruster -X x TH-TCS031 Yellowspring (10kohm, YSI) DRS Colloid Thruster -X x
TH-TCS032 Yellowspring (10kohm, YSI) FEEP Thruster Cluster +X+Y Interface x x
TH-TCS033 Yellowspring (10kohm, YSI) FEEP Thruster Cluster +X+Y Interface x
TH-TCS034 Yellowspring (10kohm, YSI) FEEP Thruster Cluster +X+Y Interface x
TH-TCS035 Yellowspring (10kohm, YSI) DRS +X Colloid Thruster, +Y+Z Nozzle x
TH-TCS036 Yellowspring (10kohm, YSI) DRS +X Colloid Thruster, -Y-Z Nozzle x
TH-TCS037 Yellowspring (10kohm, YSI) DRS -X Colloid Thruster, +Y+Z Nozzle x
TH-TCS038 Yellowspring (10kohm, YSI) DRS +X Colloid Thruster, -Y-Z Nozzle x
TH-TCS039 Yellowspring (10kohm, YSI) DRS IAU x TH-TCS040 Yellowspring (10kohm, YSI) EPDP CDA x TH-TCS041 Yellowspring (10kohm, YSI) EPDP PCU x
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 21 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
Function (TBC) Thermistor
Number Thermistor Type Location (TBC) Monitoring
TMV Heater Control
Fine Temperature Measurement
Windowing
TH-TCS042 Yellowspring (10kohm, YSI) EPDP PDA x TH-TCS043 Yellowspring (10kohm, YSI) FEEP Interconnect +X+Y x TH-TCS044 Yellowspring (10kohm, YSI) FEEP Interconnect -X+Y x TH-TCS045 Yellowspring (10kohm, YSI) FEEP Interconnect -Y x
TH-TCS046 Yellowspring (10kohm, YSI) FEEP Neutraliser assembly +X+Y x
TH-TCS047 Yellowspring (10kohm, YSI) FEEP Neutraliser assembly -X+Y x
TH-TCS048 Yellowspring (10kohm, YSI) FEEP Neutraliser assembly -X-Y x
TH-TCS049 Yellowspring (10kohm, YSI) FEEP PCU +X+Y x TH-TCS050 Yellowspring (10kohm, YSI) FEEP PCU -X+Y x TH-TCS051 Yellowspring (10kohm, YSI) FEEP PCU -Y x
TH-TCS052 Yellowspring (10kohm, YSI) FEEP Thruster Cluster +X+Y Internal x
TH-TCS053 Yellowspring (10kohm, YSI) FEEP Thruster Cluster -X+Y Interface x
TH-TCS054 Yellowspring (10kohm, YSI) FEEP Thruster Cluster -X+Y Internal x
TH-TCS055 Yellowspring (10kohm, YSI) FEEP Thruster Cluster -Y Interface x
TH-TCS056 Yellowspring (10kohm, YSI) FEEP Thruster Cluster -Y Internal x
TH-TCS057 Yellowspring (10kohm, YSI) Gyro +X x TH-TCS058 Yellowspring (10kohm, YSI) Gyro -X x TH-TCS059 Yellowspring (10kohm, YSI) LGA +X-Y x TH-TCS060 Yellowspring (10kohm, YSI) LGA -X+Y x TH-TCS061 Yellowspring (10kohm, YSI) LTP CCU x TH-TCS062 Yellowspring (10kohm, YSI) LTP DMU x TH-TCS063 Yellowspring (10kohm, YSI) LTP Fibre Box x TH-TCS064 Yellowspring (10kohm, YSI) LTP IS FEE PCU x
TH-TCS065 Yellowspring (10kohm, YSI) LTP IS FEE SAU Switching Unit (SSU) x
TH-TCS066 Yellowspring (10kohm, YSI) LTP Magnetometer +X x TH-TCS067 Yellowspring (10kohm, YSI) LTP Magnetometer +Y x TH-TCS068 Yellowspring (10kohm, YSI) LTP Magnetometer -X x TH-TCS069 Yellowspring (10kohm, YSI) LTP Magnetometer -Y x TH-TCS070 Yellowspring (10kohm, YSI) LTP Radiation monitor x TH-TCS071 Yellowspring (10kohm, YSI) LTP ULU x TH-TCS072 Yellowspring (10kohm, YSI) MGA x TH-TCS073 Yellowspring (10kohm, YSI) OBC x TH-TCS074 Yellowspring (10kohm, YSI) PCDU x TH-TCS075 Yellowspring (10kohm, YSI) STE (DPU) +Z x TH-TCS076 Yellowspring (10kohm, YSI) STE (DPU) -Z x
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 22 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
Function (TBC) Thermistor
Number Thermistor Type Location (TBC) Monitoring
TMV Heater Control
Fine Temperature Measurement
Windowing
TH-TCS077 Yellowspring (10kohm, YSI) Sun sensor +X+Y 1 x TH-TCS078 Yellowspring (10kohm, YSI) Sun sensor +X+Y 2 x TH-TCS079 Yellowspring (10kohm, YSI) Sun sensor -X-Y x TH-TCS080 Yellowspring (10kohm, YSI) Transponder +Z x TH-TCS081 Yellowspring (10kohm, YSI) Transponder -Z x TH-TCS082 Yellowspring (10kohm, YSI) Umbilicals +X+Y x TH-TCS083 Yellowspring (10kohm, YSI) Umbilicals +X-Y x TH-TCS084 Yellowspring (10kohm, YSI) Umbilicals -X+Y x TH-TCS085 Yellowspring (10kohm, YSI) Umbilicals -X-Y x TH-TCS086 Yellowspring (10kohm, YSI) Spare x TH-TCS087 Yellowspring (10kohm, YSI) Spare x TH-TCS088 Rosemont PT1000 Solar Array x TH-TCS089 Rosemont PT1000 Solar Array x TH-TCS090 Rosemont PT1000 Solar Array x Total 74 24 12
Table 5: List of SCM Thermistors
5.10 Thermocouples
The location of the SCM thermal test thermocouples are TBC, however the test facility can support up to 300 + 30 spares for installation.
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 23 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
INTENTIONALLY BLANK
LISA Pathfinder
S2.ASU.ICD.2017Issue 1
Page 24 of 24
Astrium Limited owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner.
S2.ASU.ICD.2017 ISS01 SCM Therma Hardware Definition.doc
DOCUMENT CHANGE DETAILS
ISSUE CHANGE AUTHORITY CLASS RELEVANT INFORMATION/INSTRUCTIONS
1 - - Initial Issue
DISTRIBUTION LIST
INTERNAL
EXTERNAL
S. Barraclough ESA A.G, Jones N. Dunbar G. Adams M. Backler
Configuration Management