A modular system, C1 consists of three components: frame, electricalsystem and reflector.

First is a frame that accommodates fouraperture sizes. Frames can be ordered in4", 6", 8" or 10" apertures, with the four-, six- and eight-inch having interchangeablecapability. A remodel housing is availablein the 6", 8" and10" sizes for use in existingceiling systems. Sloped ceiling housingsare available in 8” and 10” diameters.

Frames can be installed even before a lamp source or wattage has been determined.

The second component is an electricalsystem. C1 electrical systems are designedaround incandescent, compact fluorescentor HID lamp sources of all shapes andwattages, and connect to the frame via a junction box door.

Capri One electrical assemblies areinterchangeable and can be retrofittedeven after installation.

Completing the system is a family of over 200 reflectors, developed exclusivelyfor Capri One. We offer a wide range ofavailable options, including self-flangedreflectors, cross baffles, and nonconductiveshower reflectors. Many Capri One reflectorsare C/UL listed for wet location use.

The C1 system was designed as much for quick delivery as it was forease of use —a lighting system thatinstalls without the use of tools, withoff-the-shelf components you can mix and match to meet your particularlighting needs. Components can be shipped separately, or as a system.

www.caprilighting.com

Capri offers remodel housingsfor existing commercial ceilingsystems. The CM6R, CM8R and CM10R metal remodel housings can be used with standard 6", 8" and 10" reflectorsand electrical systems.

Interchangeable insert ringsare securely fastened to the CM4,CM6 and CM8 metal frames with

two wing nuts. Insert rings can alsobe ordered separately. See page 44

for ordering information.

O N E ®C A P R I

CMR4 CMR6 CMR8

New Capri One butterfly brackets now accept BH-1

adjustable bar hangers to provide awider choice of installation options.

Slope ceiling applications: CM8S and CM10S metal slope ceiling frames are available for both horizontal and vertical slope reflectors. They can be used with ceilings sloped from 5 to 45 degrees.

CFL INC HID T A B L E O F C O N T E N T S

2 Ordering Information

4 Electrical Systems

4" Aperture

8 Compact Fluorescent

9 Incandescent

10 HID / Metal Halide

11 4" Reflectors

6" Aperture

12 Compact Fluorescent / Vertical

14 Compact Fluorescent / Horizontal

18 Incandescent

20 HID / Metal Halide

8" Aperture

22 Compact Fluorescent / Vertical

24 Compact Fluorescent / Horizontal

28 Incandescent

30 HID / Metal Halide

10" Aperture

32 Compact Fluorescent / Vertical

34 Compact Fluorescent / Horizontal

40 Incandescent

42 HID / Metal Halide

44 Accessories

45 Bar Hangers and Fuse Kits

46 Product Matrix

47 Specifications / Lamp Data

Capri One: The ultimate in flexibility and convenience forcommercial downlighting.

www.caprilighting.com

4

6

8

10

2

ww

w.c

apri

light

ing.

com

How to Order Capri OneThere are three components to the Capri One (C1) System: The first component is the plaster frame, the second is an electrical system,and the third is a reflector. Frames and electrical systems can be orderedtogether as a complete unit, or separately.

FramesMetal frames can be ordered for 4", 6", 8" or 10"apertures, with remodel and sloped ceiling options available in sizesshown below.

6" aperture standard frame (CM6). 2-26W, 2-32W or 2-42W compact fluorescent unit with 120V-277V universal electronic ballast.

F226/32/42UCM6

Ordering Example Frames Ordering Example Electrical Systems

Electrical SystemsA wide variety of electrical systems are available for use with all C1 frames. Capri One electrical systems are interchangeablebetween 4", 6", 8" and 10" sizes, apart from a few wattage restrictions. Electrical connections are made through a singlejunction box door, which allows all electrical systems to snapeasily into place on the frame.

All Capri One electrical systems ship with pre-installedquick connectors for fast and simple electrical splices.Electrical systems may be ordered separately or togetherwith a frame.

Metal Frames

CM4 Standard frame with 4” aperture

CM6 Standard frame with 6” aperture

CM6R* Remodel frame with 6” aperture

CM8 Standard frame with 8” aperture

CM8R* Remodel frame with 8” aperture

CM8S Slope frame with 8” aperture

CM10 Standard frame with 10” aperture

CM10R* Remodel frame with 10” aperture

CM10S Slope frame with 10” aperture

Example: CM6

*Not for use with magnetic HID or compact fluorescent with emergency options.

CM6

ww

w.caprilighting.com

3

New to Capri One

Lamp Orientation (choose one)

V Vertical lamp orientation

H Horizontal lamp orientation

Example: V

Reflector Classification–optional (choose one)

W Single wall wash

WD Double wall wash

Example: VWD (when ordering wall wash trims, baffle/lens options are not available)

Aperture Size (choose one)

4 4" aperture 8 8" aperture

6 6" aperture 10 10" aperture

Example: V6

Reflector Finishes (choose one)

3 Gold 5 Clear Specular 7 Wheat

4 Black 6 White

Example: V65

Baffle/Lens Options (choose one)

E Emergency (integral only) P Prismatic lens

F Fresnel lens C Clear lens

Example: V65C

ReflectorsC1reflectors are available in 4", 6", 8" or 10" apertures. A broadselection of reflectors can be ordered with lenses or baffles.Many C1 trims are listed for use in wet location areas.

Reflectors are held in place with expandable torsion springs to ensure a flush finish along the ceiling.

To create a reflector catalog number, begin with a lamp orientation. Next, choose from among aperture sizes, finishes, and a variety of baffle and lens options.

Vertical, 6" reflector with clear specular finish and clear glass lens.

V65C

Ordering Example Reflectors

Dual-level switching is now availablefor all multi-lamp CFL systems.All horizontal, multi-lamp, C1 electrical systems feature an optional dual-ballast system for dual-level switching. 2-lamp versions operate each lamp independently, while the 3-lamp systems have in-board/out-board capabilities.Dual-level switching is available in all CFL wattages from 13-watt through 42-watt.

HID systems now feature electronicballasts to conform to EISA.Small size, high efficiency, improved lumen maintenance,and excellent lamp regulation have made electronic HID systems a top choice among specifiers and contractors.

Adjustable Reflectors for Capri One 6" Systems

An adjustable reflector is now available for the 6” HID and Incandescent families of C1. These new reflectors accommodate PAR30 lamps in both HID and Incandescentand feature 360º horizontal rotation and 30º vertical aiming.Adjustable reflectors are available in a wide variety of finishes.

4

ww

w.c

apri

light

ing.

com

Lamp OrientationFV Single vertical lamp

F1 Single horizontal lamp

F2 Double horizontal lamp

F3 Triple horizontal lamp (10" only)

Example: FV32

Ballast Options (choose one)U 120-277 volt electronic ballast

S3 347 volt electronic ballast

DL1 120 volt dimming, Lutron Compact SE

DL2 277 volt dimming, Lutron Compact SE

Continued in the next column

Ballast Options (continued)DX1 120 volt dimming, Advance Mark X

DX2 277 volt dimming, Advance Mark X

DB Dual level switching

Example: FV32DL1

Electrical AccessoriesRI Radio interference filter

FS2 Fuse kit

Example: FV32DL1FS2

Emergency Options1 (choose one)E Integral emergency unit

ER Remote emergency unit

Example: FV32DL1FS2E

1 When ordering an integral emergency unit, please be sure to specify anemergency reflector. Approved emergency reflectors are designated by an“E” at the end of the reflector catalog number. Ordering example: V65E.

Each system comes equipped with anelectronic ballast for optimum performance.Two-lamp systems are equipped with asingle, two -lamp ballast. The socket cupsattach directly to the reflectors without the need for tools, and quick connectors are pre-installed for fast and simple wiring splices. All electrical connections are made through a single junction box door, which allows the

electrical systems to snap easily into place on the frame.

Compact fluorescent electrical systemnumbering begins with lamp orientation.Choose from ballast and voltage optionsranging from13 to 57 watts. Capri One CFL systems also offer dual-level switching and dimming, fusing, RI filter, and both integral and remote emergency options.

Compact fluorescent electrical systems are availablein vertical or horizontal lamp orientations.

Compact FluorescentVertical I Page 8

Vertical I Page 12Horizontal 1- & 2-Lamp I Pages 14 -17

Vertical I Page 22Horizontal 1- & 2-Lamp I Pages 24 -27

Vertical I Page 32Horizontal 1- & 2-Lamp I Pages 34 -37Horizontal 3-Lamp I Page 38

4

6

8

10

For use with four pin, electronic quad and triple tube lamps, 13 to 57 watts.Please refer to specific product pages for maximumwattage information.

ww

w.caprilighting.com

5

The unit is thermally protected and thevertical socket cup is adjustable for variouslamp sizes and beam spreads. The socket cup also attaches to the trim without theneed for tools, and quick connectors are

pre-installed for fast and simple wiring splices.All electrical connections are made through a single junction box door, which allows theelectrical system to snap easily into place on the frame.

The A300 incandescent electrical system is rated foruse with a wide variety of lamps up to 300 watts.

Incandescent4

6

8

10

Page 9

Page 18

Page 28

Page 40

For use with A, BR and PAR lamps of various sizes up to 300 watts. Please refer to specific product pages for maximum wattage information.

6

ww

w.c

apri

light

ing.

com

Lamp TypeM Protected, or open metal halide2

ML Lensed, or enclosed metal halide

Example: ML100

Voltage Options (choose one)EB1 120 volt electronic ballast

EB2 277 volt electronic ballast

EBU 120/277 volt electronic ballast

C 120/347 volt magnetic ballast

Example: ML100EBU

Fuse OptionsSee page 45 for fuse kit options

Example: ML100EBUFS4

Emergency Options3

E Integral emergency restrike unit

EX Emergency restrike (10" only)

Example: ML100EBUFS4E

Capri Lighting applauds and supports the Energy IndependenceSecurity Act (EISA) that goes into effect January 1, 2009. Its longterm goal of reducing our dependence on foreign energy sourceswhile helping to reduce global climate changes will only beachieved through the support of manufacturers of quality lightingfixtures that comply. With that, Capri One now features electronicHID ballasts on all HID products from 20 watts through 150 watts

as a standard. Capri will continue to offer magnetic HID optionsin 35 watts through 100 watt fixtures for those who prefer magneticoptions. EISA regulations do not allow magnetic HID systems in150 watt and above to be sold in the United States.

To fully appreciate the benefits derived from utilizing electronicHID, refer to the detailed information on the opposite page.

Capri C1 now features electronic HID ballasts.

HIDPage 10

Page 20

Page 30

Page 42

4

6

8

10

1 Effective January 1, 2009, electronic ballasts will be standard due to EISA (Energy Independence Security Act). For magnetic ballast availability, contact factory. 2 Metal halide electrical systems for use with protected or open rated lamps have a special socket preventing application of lamps not suitable for open rated fixtures.3 When ordering an integral emergency unit, please be sure to specify an emergency reflector. Approved integral emergency reflector are designated by an “E” at the end of the reflector catalog number. Ordering example: V65E.

Electronic HID Ballasts

ww

w.caprilighting.com

7

O N E ®C A P R I

With the introduction of many new HID lampsand ballasts, electronic HID systems havebecome an increasingly popular choice amonglighting designers, specifiers, architects, and design/build contractors. Electronic HID systems offer manydesirable features such as small size, high efficiency,improved lumen maintenance, and excellent lamp regulation, to name a few.

Performance Benefits:Better Lumen MaintenanceBetter Color ControlImproved Energy SavingsReduced Color Shift

Physical Benefits:Size Reduction and Less WeightClass “A” Sound RatingCooler OperationEnd-of-Life Protection

One feature of electronic HID ballasts is a circuit which removes power to the lamp at itsend-of-life. This is commonly referred to as “End-of-Lamp Life” (EOLL) protection. When triggered, the

EOLL protection will turn the ballast off. Triggering of the EOLL circuit will occur at end-of-lamp life or if no lamp is installed while the ballast is powered.When replacing a lamp, power to the ballast shouldbe cycled off and back on to ignite the lamp. Cyclingpower whenever a lamp is replaced can potentiallyreduce unnecessary servicing.

Many in the lighting industry now recognize thebenefits of using Electronic HID (E-HID) ballastswith ceramic metal halide (CMH) and Pulse Start MH lamps, compared with either incandescent or magnetic ballast systems: great white color, consistent color throughout the life of the lamp, and energy efficiency. An additional benefit is a reduction of circuit loads. Lower input current requirements offered by E-HID ballasts allow more fixtures per branch circuit in new installations, thuslowering installation material and labor costs.

The table below shows a fixtures-per-circuit comparisonfor three systems. Systems in each column representsimilar total lumen output.

E-HID ballasts allow a significant increase in fixtures percircuit, thus lowering installation costs accordingly.

E-HID ballasts for use with ED17, PAR 20, PAR30 and PAR38 metal halide lamps, 20 to 150 watts. Please refer to specific productpages for maximum wattage information.

1 2 3Lamp/Ballast Watts/Fixt. Count1 Watts/Fixt. Count1 Watts/Fixt. Count1

Halogen Incandescent 75W / 25 100W / 19 150W / 15

Ceramic MH/Magnetic N/A2 39W / 22 50W / 23

Ceramic MH/Electronic 20W / 80 39W / 40 50W / 35

1 Fixture count per 20A circuit @120V2 No magnetic system available for 20W CMH

4 CFL C O M P A C T F L U O R E S C E N T 4 "

V E R T I C A L

CM4Metal frame with 4" aperture.The 4" ring onthe CM4 canbe replaced with a 6" or 8"ring (ordered separately) inthe field if needed.

Frame

Electrical

8

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

9 1/2"(241 mm)

4 7/8"(124 mm)

5 3/32"(129 mm)

6 5/32"(156 mm)

7/8"(22 mm)

15"(381 mm)

19 3/16"(487 mm)

4" Standard VerticalFixture with Emergency

Option (frame: CM4)

Ballast Options (choose one) EmergencyElectronic Lutron Dimming Advance Dimming Radio Option

Catalog Lamp 120-277V 347V 120V 277V 120V 277V Filter Fuse RemoteNumber Designation U S3 DL11 DL21 DX12 DX22 RI F3 ER4

FV13 (1) CFQ13W/G24q � � � �

FV18 (1) CFQ18W/G24q, (1) CFM18W/GX24q � � � � � � � � �

FV26/32/42 (1) CFQ26W/G24q, (1) CFM26W/GX24q,� � � �(1) CFM32W/GX24q, (1) CFM42W/GX24q

FV26 (1) CFQ26W/G24q, (1) CFM26W/GX24q � � � � � � � �

FV32 (1) CFM32W/GX24q � � � � � � � �

FV42 (1) CFM42W/GX24q � � � � � � � �

1Lutron Compact SE dimming, DL1 (120V), DL2 (277V). 3-wire system.2Advance Mark X dimming, DX1 (120V), DX2 (277V). 2-wire system.3Fuse kits are field installed. For large projects, consult factory for information on factory installation.4Initial lumens shown.

350lumens

350lumens

425lumens

600lumens

750lumens

14 7/8"(378 mm)

13 25/32"(350 mm)

10 1/4"(260 mm)

4 7/8"(124 mm)5 1/2 "

(140 mm)6 5/32"

(156 mm)

9 5/8"(244 mm)

7/8"(22 mm)

4" Standard Vertical Fixture (frame: CM4)

RemoteOption

4INCFrame

I N C A N D E S C E N T 4 "

V E R T I C A Lw

ww

.caprilighting.com

9

Electrical

CM4Metal frame with 4"aperture.The 4" ring onthe CM4 canbe replaced with a 6" or 8"ring (ordered separately) inthe field if needed.

Maximum WattageCatalog V44 Black andNumber Incandescent Lamp Type Typical Reflectors Lensed Reflectors

A300 A 60W 50W

PAR16 75W 60W

PAR20 60W 60W

NOTE: Bar hangers not included.See page 45 for ordering information.

15 3/4"(400 mm)

13 25/32"(350 mm)

10 1/4"(260 mm)

4 7/8"(124 mm)5 1/2"

(136 mm)6 5/32"(156 mm)

9 5/8"(244 mm)

7/8"(22 mm)

4" Standard IncandescentFixture (frame: CM4)

Electronic Ballasts (standard)1Magnetic Ballast Options Fuse(choose one)

120/277V 120/347V Options3

Catalog Lamp 120V 277V 120/277V Consult Factory See ChartNumber Designation EB1 EB2 EBU for availability C2

Page 45

ELECTRONIC ONLY

M204 CMH20/PAR30, CMH20/PAR20 (ANSI M156) � � N/A �

ML205 CMH20/PAR30, CMH20/PAR20 (ANSI M156) � � N/A �

ELECTRONIC / MAGNETIC COMPATIBLE

M354,6 CMH35/PAR30, CMH35/PAR20 (ANSI M130) � Available � �

ML355,6 CMH35/PAR30, CMH35/PAR20 (ANSI M130) � Available � �

M504 CMH50/ED-17P/C/MED, MP50/ED-17/C/MED� Available � �(ANSI M110, M148)

ML505 CMH50/ED-17/C/MED, M50/ED-17/C/MED� Available � �(ANSI M110, M148)

M704 CMH70/PAR 38, CMH70/PAR 30, CMH70/ED-17P/C/MED, � Available � �MP70/ED-17/C/MED (ANSI M98, M143)

ML705 CMH70/PAR 38, CMH70/PAR 30, CMH70/ED-17/C/MED,� Available � �M70/ED-17/C/MED (ANSI M98, M143)

1Effective January 1, 2009, Electronic ballasts are standard to conform to EISA. Consult factory for magnetic availability.2347V available only on magnetic ballasts.3HID Fuse kits vary depending on wattage and voltage. Refer to chart on page 45 to determine the correct fuse kit for your application.4Use open rated lamps only.5For use with lensed trims only. 6Actual lamp wattage is 39 watts.

4 HID M E T A L H A L I D E 4 "

V E R T I C A L

CM4Metal frame with 4"aperture.The 4" ring onthe CM4 canbe replaced with a 6" or 8"ring (ordered separately) inthe field if needed.

Frame

Electrical

10

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

14 7/8"(378 mm)

13 25/32"(350 mm)

10 1/4"(260 mm)

4 7/8"(124 mm)5 1/2 "

(140 mm)6 5/32"

(156 mm)

9 5/8"(244 mm)

7/8"(22 mm)

4" Standard HID Fixture (frame: CM4)

4Reflectors

C O M P A C T F L U O R E S C E N T / I N C A N D E S C E N T / H I D 4 "

V E R T I C A L

V44Black Reflector

V43Gold Reflector

V45Low Iridescent Clear Reflector V45SLLow Iridescent, Self-Flanged*

V46White Reflector

V45BLow Iridescent Reflector, Black Baffle

V47Wheat Reflector

V45WBLow Iridescent Reflector, White Baffle

White Baffle, Glass Lens InsertV45WBCClear LensV45WBPC73 Prismatic Lens

White Splay, Glass Lens InsertV46CClear LensV46PC73 Prismatic Lens

Clear Cone, Glass Lens InsertV45CClear LensV45PC73 Prismatic Lens

Black Baffle, Glass Lens InsertV45BCClear LensV45BPC73 Prismatic Lens

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM4-ML20EB1-V46P-BH11

ww

w.caprilighting.com

11

6 CFL C O M P A C T F L U O R E S C E N T 6 "

V E R T I C A L

CM6Metal frame with 6"aperture.The 6" ring onthe CM6 canbe replaced with a 4" or 8"ring (ordered separately) inthe field if needed.

Frame

Electrical

CM6RRemodel metal frame for 6"aperture applications.Not for use with emergency options.

12

6" Standard Vertical Fixture (frame: CM6)

6" Remodel MetalFrame (frame: CM6R)

5 27/32"(148 mm)

7 7/64"(180 mm)

10 19/32"(269 mm)

7 7/16"(189 mm)

6 15/32"(164 mm)

7 1/16"(179 mm)

2 1/2"(64 mm)

14 7/8"(378 mm)

13 25/32"(350 mm)

10 1/4"(260 mm)

7 3/4"(197 mm)

6 3/4"(172 mm)

6 1/2"(165 mm)

10"(254 mm)

( )

7/8"(22 mm)

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

Ballast Options (choose one) Emergency OptionsElectronic Lutron Dimming Advance Dimming Radio (choose one)

Catalog Lamp 120-277V 347V 120V 277V 120V 277V Filter Fuse Integral RemoteNumber Designation U S3 DL11 DL21 DX12 DX22 RI F3 E4,5 ER5,6

FV13 (1) CFQ13W/G24q � � � � �

FV18 (1) CFQ18W/G24q, (1) CFM18W/GX24q � � � � � � � � � �

FV26/32/42 (1) CFQ26W/G24q, (1) CFM26W/GX24q,� � � � �(1) CFM32W/GX24q, (1) CFM42W/GX24q

FV26 (1) CFQ26W/G24q, (1) CFM26W/GX24q � � � � � � � � �

FV32 (1) CFM32W/GX24q � � � � � � � � �

FV42 (1) CFM42W/GX24q � � � � � � � � �

1Lutron Compact SE dimming, DL1 (120V), DL2 (277V). 3-wire system.2Advance Mark X dimming, DX1 (120V), DX2 (277V). 2-wire system.3Fuse kits are field installed. For large projects, consult factory for information on factory installation.4Use with emergency “E” option trims only. 5Not available for remodel systems or shower trims.6Initial lumens shown.

350lumens

350lumens

425lumens

600lumens

750lumens

7 3/4"(197 mm)

6 3/4" (172 mm)

6 1/2"(165 mm)

10"(254 mm)

7/8"(22 mm)

RemoteOption

Integral Option

10 1/4"(260 mm)

17 3/16"(436 mm)

15"(381 mm)

6" Standard VerticalFixture with Emergency

Option (frame: CM6)

6CFLReflectors

C O M P A C T F L U O R E S C E N T 6 "

V E R T I C A L

V64Black Reflector V64EBlack, EmergencyV64SLBlack, Self-Flanged*

V63Gold Reflector V63EGold, EmergencyV63SLGold, Self-Flanged*

V65Low Iridescent Clear Reflector V65ELow Iridescent, EmergencyV65SLLow Iridescent, Self-Flanged*V65SLELow Iridescent, Self-Flanged*,Emergency

V66White Reflector V66EWhite, EmergencyV66SLWhite, Self-Flanged*

V65BLow Iridescent Reflector, Black Baffle V65BELow Iridescent, Black Baffle,Emergency

V67Wheat Reflector V67EWheat, EmergencyV67SLWheat, Self-Flanged*

V65WBLow Iridescent Reflector, White Baffle V65WBELow Iridescent, White Baffle,Emergency

V65SWRPolycarbonate Shower TrimNot available with Emergency Option

VW65Low Iridescent Clear Reflector,Single Wall Wash (shown) VW65SLLow Iridescent, Single Wall Wash,Self-Flanged*VWD65Low Iridescent, Double Wall Wash

VW63Gold Reflector, Single Wall Wash (shown)VWD63Gold, Double Wall Wash

V65XBLow Iridescent Cross Baffle ReflectorV65XBELow Iridescent Cross Baffle Reflector,Emergency

White Baffle, Glass Lens InsertV65WBCClear LensV65WBFFresnel LensV65WBPC73 Prismatic Lens

White Splay, Glass Lens InsertV66CClear LensV66FFresnel LensV66PC73 Prismatic Lens

Clear Cone, Glass Lens InsertV65CClear LensV65FFresnel LensV65PC73 Prismatic Lens

Black Baffle, Glass Lens InsertV65BCClear LensV65BFFresnel LensV65BPC73 Prismatic Lens

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM6-FV18DL2ER-V65WB-BH31

ww

w.caprilighting.com

13

CFL C O M P A C T F L U O R E S C E N T 6 "

H O R I Z O N T A L

CM6Metal frame with 6"aperture.The 6" ring onthe CM6 canbe replaced with an 8" ring(ordered separately) in thefield if needed.

Frame

Electrical

14

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

13 3/4"(350 mm)

10 1/4"(260 mm)

14 7/8"(378 mm)

7 3/4"(197 mm)

6 3/4"(172 mm)

6 1/2"(165 mm)

6 5/16"(160 mm)

7/8"

(22 mm)

10 1/4"(260 mm)

17 3/16"(436 mm)

15"(381 mm)

7 3/4"(197 mm)

6 3/4"(172 mm)

6 1/2"(165 mm)

7"(178 mm)

7/8"(22 mm)

5 1/2"(140 mm)

RemoteOption

IntegralOption

6" Standard Horizontal Fixture (frame: CM6)

6" Standard HorizontalFixture with Emergency

Option (frame: CM6)

6

Ballast Options (choose one) Emergency OptionsElectronic Lutron Dimming Advance Dimming Radio (choose one)

Catalog Lamp 120-277V 347V 120V 277V 120V 277V Filter Fuse Integral RemoteNumber Designation U S3 DL11 DL21 DX12 DX22 RI F3 E4,5 ER5,6

F113 (1) CFQ13W/G24q � � � � �

F118 (1) CFQ18W/G24q, (1) CFM18W/GX24q � � � � � � � � � �

F126/32/42 (1) CFQ26W/G24q, (1) CFM26W/GX24q,� � � � �(1) CFM32W/GX24q, (1) CFM42W/GX24q

F126 (1) CFQ26W/G24q, (1) CFM26W/GX24q � � � � � � � � �

F132 (1) CFM32W/GX24q � � � � � � � � �

F142 (1) CFM42W/GX24q � � � � � � � � �

1Lutron Compact SE dimming, DL1 (120V), DL2 (277V). 3-wire system.2Advance Mark X dimming, DX1 (120V), DX2 (277V). 2-wire system.3Fuse kits are field installed. For large projects, consult factory for information on factory installation.4Use with emergency “E” option trims only. 5Not available for remodel systems or shower trims.6Initial lumens shown.

6" Remodel MetalFrame (frame: CM6R)

5 27/32"(148 mm)

7 7/64"(180 mm)

10 19/32"(269 mm)

7 7/16"(189 mm)

6 15/32"(164 mm)

7 1/16"(179 mm)

2 1/2"(64 mm)

350lumens

350lumens

425lumens

600lumens

750lumens

CM6RRemodel metal frame for 6"aperture applications.Not for use with emergency options.

6CFLReflectors

C O M P A C T F L U O R E S C E N T 6 "

H O R I Z O N T A L

H65Low Iridescent Clear Reflector H65ELow Iridescent, EmergencyH65SLLow Iridescent, Self-Flanged*H65SLELow Iridescent, Self-Flanged*,Emergency

H63Gold Reflector H63EGold, EmergencyH63SLGold, Self-Flanged*H63SLEGold, Self-Flanged*,Emergency

H66White Reflector H66EWhite, EmergencyH66SLWhite, Self-Flanged*

H67Wheat Reflector H67EWheat, EmergencyH67SLWheat, Self-Flanged*

HWD63Gold Reflector,Double Wall Wash

HW63Gold Reflector,Single Wall Wash

HW65Low Iridescent Clear Reflector,Single Wall Wash (shown)HW65SLLow Iridescent, Single Wall Wash,Self-Flanged*

HWD65Low Iridescent Clear Reflector,Double Wall Wash

H65SWRPolycarbonate Shower TrimNot available with Emergency Option

H65XBLow Iridescent Cross Baffle Reflector H65XBELow Iridescent Cross Baffle Reflector, Emergency

Black Baffle, Glass Lens InsertH65BCClear LensH65BFFresnel LensH65BPC73 Prismatic Lens

Clear Cone, Glass Lens InsertH65CClear LensH65FFresnel LensH65PC73 Prismatic Lens

White Splay, Glass Lens InsertH66CClear LensH66FFresnel LensH66PC73 Prismatic Lens

White Baffle, Glass Lens InsertH65WBCClear LensH65WBFFresnel LensH65WBPC73 Prismatic Lens

H65WBLow Iridescent Reflector,White Baffle H65WBELow Iridescent, White Baffle,Emergency

H65BLow Iridescent Reflector,Black Baffle H65BELow Iridescent, Black Baffle,Emergency

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM6-F126DX1E-H65WBE-CH241

ww

w.caprilighting.com

15

CFL C O M P A C T F L U O R E S C E N T 6 "

H O R I Z O N T A L 2 - L A M P

CM6Metal frame with 6"aperture.The 6" ring onthe CM6 canbe replaced with an 8" ring(ordered separately) in thefield if needed.

Frame

Electrical

16

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

6

Ballast Options (choose one) EmergencyLutron Advance Options

Electronic Dimming Dimming Dual-Level Radio (choose one)

Catalog Lamp 120-277V 347V 120V 277V 120V 277V Switching Filter Fuse Integral RemoteNumber Designation U S3 DL11 DL21 DX12 DX22 DB RI F3 E4,5 ER5,6

F213 (2) CFQ13W/G24q � � � � � � �

F218 (2) CFQ18W/G24q � � � � � � � � � � �

F226/32/427 (2) CFQ26W/G24q � 8 � � � � �

F226 (2) CFQ26W/G24q � � � � � � � � � �

1Lutron Compact SE dimming, DL1 (120V), DL2 (277V). 3-wire system.2Advance Mark X dimming, DX1 (120V), DX2 (277V). 2-wire system.3Fuse kits are field installed. For large projects, consult factory for information on factory installation.4Use with emergency “E” option trims only. 5Not available for remodel systems or shower trims.6Initial lumens shown. 7For use with 26 watt quad lamps only in 6” horizontal trims. 8Consult factory for availability.

6" Remodel MetalFrame (frame: CM6R)

5 27/32"(148 mm)

7 7/64"(180 mm)

10 19/32"(269 mm)

7 7/16"(189 mm)

6 15/32"(164 mm)

7 1/16"(179 mm)

2 1/2"(64 mm)

350lumens

350lumens

425lumens

13 3/4"(350 mm)

10 1/4"(260 mm)

14 7/8"(378 mm)

7 3/4"(197 mm)

6 3/4"(172 mm)

6 1/2"(165 mm)

6 5/16"(160 mm)

7/8"

(22 mm)

10 1/4"(260 mm)

17 3/16"(436 mm)

15"(381 mm)

7 3/4"(197 mm)

6 3/4"(172 mm)

6 1/2"(165 mm)

7"(178 mm)

7/8"(22 mm)

5 1/2"(140 mm)

RemoteOption

IntegralOption

6" Standard Horizontal Fixture (frame: CM6)

6" Standard HorizontalFixture with Emergency

Option (frame: CM6)

CM6RRemodel metal frame for 6"aperture applications.Not for use with emergency options.

6CFLReflectors

C O M P A C T F L U O R E S C E N T 6 "

H O R I Z O N T A L 2 - L A M P

H65Low Iridescent Clear Reflector H65ELow Iridescent, EmergencyH65SLLow Iridescent, Self-Flanged*H65SLELow Iridescent, Self-Flanged*,Emergency

H63Gold Reflector H63EGold, EmergencyH63SLGold, Self-Flanged*H63SLEGold, Self-Flanged*,Emergency

H66White Reflector H66EWhite, EmergencyH66SLWhite, Self-Flanged*

H67Wheat Reflector H67EWheat, EmergencyH67SLWheat, Self-Flanged*

HWD63Gold Reflector,Double Wall Wash

HW63Gold Reflector,Single Wall Wash

HW65Low Iridescent Clear Reflector,Single Wall Wash (shown)HW65SLLow Iridescent, Single Wall Wash,Self-Flanged*

HWD65Low Iridescent Clear Reflector,Double Wall Wash

H65SWRPolycarbonate Shower TrimNot available with Emergency Option

H65XBLow Iridescent Cross Baffle Reflector H65XBELow Iridescent Cross Baffle Reflector, Emergency

Black Baffle, Glass Lens InsertH65BCClear LensH65BFFresnel LensH65BPC73 Prismatic Lens

Clear Cone, Glass Lens InsertH65CClear LensH65FFresnel LensH65PC73 Prismatic Lens

White Splay, Glass Lens InsertH66CClear LensH66FFresnel LensH66PC73 Prismatic Lens

White Baffle, Glass Lens InsertH65WBCClear LensH65WBFFresnel LensH65WBPC73 Prismatic Lens

H65WBLow Iridescent Reflector,White Baffle H65WBELow Iridescent, White Baffle,Emergency

H65BLow Iridescent Reflector,Black Baffle H65BELow Iridescent, Black Baffle,Emergency

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM6-F218UE-H65BE-BH11

ww

w.caprilighting.com

17

6 INC I N C A N D E S C E N T 6 "

V E R T I C A L

CM6Metal frame with 6"aperture.The 6" ring onthe CM6 canbe replaced with a 4" or 8"ring (ordered separately) inthe field if needed.

Frame

Electrical

18

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

Maximum Wattage

Catalog V65SWR Typical V64 Black andNumber Incandescent Lamp Type Reflector Reflectors Lensed Reflectors

A300 A 75W 150W 100W

PAR30 75W 75W 75W

R/BR30 50W 75W 75W

PAR38 100W 150W 100W

R/BR40 100W 150W 100W

5 27/32"(148 mm)

7 7/64"(180 mm)

10 19/32"(269 mm)

7 7/16"(189 mm)

6 15/32"(164 mm)

7 1/16"(179 mm)

2 1/2"(64 mm)

14 3/8"(365 mm)

13 3/4"(350 mm)

9 1/2"(241 mm)

7 3/4"(197 mm)

6 3/4"(172 mm)

6 1/2"(165 mm)

10"(254 mm)

7/8"(22 mm)

6" Standard IncandescentFixture (frame: CM6)

6" Remodel MetalFrame (frame: CM6R)

CM6RRemodel metal frame for 6"aperture applications.

6INCReflectors

I N C A N D E S C E N T 6 "

V E R T I C A L

V64Black Reflector V64SLBlack, Self-Flanged*

V63Gold Reflector

V65Low Iridescent Clear Reflector V65SLLow Iridescent, Self-Flanged*

V66White Reflector V66SLWhite, Self-Flanged*

V65BLow Iridescent Reflector, Black Baffle

V67Wheat Reflector V67SLWheat, Self-Flanged*

V65WBLow Iridescent Reflector, White Baffle

V65SWRPolycarbonate Shower Trim

VW65Low Iridescent Clear Reflector,Single Wall Wash (shown) VW65SLLow Iridescent, Single Wall Wash,Self-Flanged*

VW63Gold Reflector, Single Wall Wash (shown)VWD63Gold, Double Wall Wash

VWD65Low Iridescent Clear Reflector,Double Wall Wash

White Baffle, Glass Lens InsertV65WBCClear LensV65WBFFresnel LensV65WBPC73 Prismatic Lens

White Splay, Glass Lens InsertV66CClear LensV66FFresnel LensV66PC73 Prismatic Lens

Clear Cone, Glass Lens InsertV65CClear LensV65FFresnel LensV65PC73 Prismatic Lens

Black Baffle, Glass Lens InsertV65BCClear LensV65BFFresnel LensV65BPC73 Prismatic Lens

Denotes c/UL wet location listing. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM6-A300-V67-BH31

ww

w.caprilighting.com

19

V65XBLow Iridescent Cross Baffle Reflector

VA66SL-30White PAR30 Adjustable, Self-Flanged*VA64SL-30Black PAR30 Adjustable, Self-Flanged*VA65SL-30Clear PAR30 Adjustable, Self-Flanged*

6 HID M E T A L H A L I D E 6 "

V E R T I C A L

CM6Metal frame with 6"aperture.The 6" ring onthe CM4 canbe replaced with a 4" or 8"ring (ordered separately) inthe field if needed.

Frame

Electrical

20

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

7 3/4"(197 mm)

6 3/4"(172 mm)

6 1/2"(165 mm)

10"(254 mm)

7/8"(22 mm)

14 7/8"(378 mm)

13 3/4"(350 mm)

10 1/4"(260 mm)

7 3/4"(197 mm)

6 3/4" (172 mm)

6 1/2"(165 mm)

10"(254 mm)

7/8"(22 mm)

RemoteOption

Integral Option

14 7/8"(378 mm)

13 3/4"(350 mm)

10 1/4"(260 mm)

6" Standard HID Fixture (frame: CM6)

6" Standard HIDFixture with Emergency

Option (frame: CM6)

Electronic Ballasts (standard)1Magnetic Ballast Options Fuse(choose one)

120/277V 120/347V Options3 EmergencyCatalog Lamp 120V 277V 120/277V Consult Factory See Chart

RestrikeNumber Designation EB1 EB2 EBU for availability C2

Page 45 E4,5

ELECTRONIC ONLY

M206 CMH20/PAR30, CMH20/PAR20 (ANSI M156) � � N/A � �

ML207 CMH20/PAR30, CMH20/PAR20 (ANSI M156) � � N/A � �

ELECTRONIC / MAGNETIC COMPATIBLE

M356,8 CMH35/PAR30, CMH35/PAR20 (ANSI M130) � Available � � �

ML357,8 CMH35/PAR30, CMH35/PAR20 (ANSI M130) � Available � � �

M506 CMH50/ED-17P/C/MED, MP50/ED-17/C/MED� Available � � �(ANSI M110, M148)

ML507 CMH50/ED-17/C/MED, M50/ED-17/C/MED� Available � � �(ANSI M110, M148)

M706 CMH70/PAR 38, CMH70/PAR 30, CMH70/ED-17P/C/MED, � Available � � �MP70/ED-17/C/MED (ANSI M98, M143)

ML707 CMH70/PAR 38, CMH70/PAR 30, CMH70/ED-17/C/MED,� Available � � �M70/ED-17/C/MED (ANSI M98, M143)

M1006 CMH100/PAR 38, CMH100/ED-17P/C/MED, � Available � � �MP100/ED-17/C/MED (ANSI M90, M140)

ML1007 CMH100/PAR 38, CMH100/ED-17/C/MED, � Available � � �M100/ED-17/C/MED (ANSI M90, M140)

1Effective January 1, 2009, Electronic ballasts are standard to conform to EISA. Consult factory for magnetic availability.2347V available only on magnetic ballasts.3HID Fuse kits vary depending on wattage and voltage. Refer to chart on page 45 to determine the correct fuse kit for your application.4Use T4 quartz bayonet base lamps.5Use with emergency "E" option trims only.6Use open rated lamps only.7For use with lensed trims only. 8Actual lamp wattage is 39 watts.

V65Low Iridescent Clear Reflector V65ELow Iridescent, Emergency V65SLLow Iridescent, Self-Flanged*V65SLELow Iridescent, Self-Flanged*,Emergency

V63Gold ReflectorV63EGold, Emergency

V66White ReflectorV66EWhite, EmergencyV66SLWhite, Self-Flanged*

V67Wheat ReflectorV67EWheat, EmergencyV67SLWheat, Self-Flanged*

V65WBLow Iridescent Reflector, White BaffleV65WBELow Iridescent, White Baffle,Emergency

V65BLow Iridescent Reflector,Black Baffle V65BELow Iridescent, Black Baffle,Emergency

V65XBLow Iridescent Cross Baffle ReflectorV65XBELow Iridescent Cross Baffle Reflector, Emergency

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM6-M70EBU-V65B-BH11

6HIDReflectors

M E T A L H A L I D E 6 "

V E R T I C A Lw

ww

.caprilighting.com

21

VW63Gold Reflector,Single Wall Wash

VWD63Gold Reflector,Double Wall Wash

VWD65Low Iridescent Clear Reflector,Double Wall Wash

VW65Low Iridescent Clear Reflector,Single Wall Wash (shown)VW65ELow Iridescent, Single Wall Wash,EmergencyVW65SLLow Iridescent, Single Wall Wash,Emergency, Self-Flanged

Black Baffle, Glass Lens InsertV65BCClear LensV65BFFresnel LensV65BPC73 Prismatic Lens

Clear Cone, Glass Lens InsertV65CClear LensV65FFresnel LensV65PC73 Prismatic Lens

White Splay, Glass Lens InsertV66CClear LensV66FFresnel LensV66PC73 Prismatic Lens

White Baffle, Glass Lens InsertV65WBCClear LensV65WBFFresnel LensV65WBPC73 Prismatic Lens

VA66SL-30White PAR30 Adjustable, Self-Flanged*VA64SL-30Black PAR30 Adjustable, Self-Flanged*VA65SL-30Clear PAR30 Adjustable, Self-Flanged*

8 CFL C O M P A C T F L U O R E S C E N T 8 "

V E R T I C A L

CM8Metal frame with 8"aperture.The 8" ring onthe CM8 canbe replaced with a 4" or 6"ring (ordered separately) inthe field if needed.

Frame

Electrical

CM8RRemodel metal frame for 8"aperture applications.Not for use with emergency options.

CM8SSlope ceiling metal framefor 8"aperture applications.For use with slope ceiling reflectors only.

Not for use with integral emergency options.

Requires ceiling cutout of 12".For use in 24" on center joist construction only.

22

8" Standard Vertical Fixture (frame: CM8)

8" Remodel MetalFrame (frame: CM8R)

8" Slope Ceiling Metal Frame (frame: CM8S)

Max Height: 14 -1/16" —see spec sheet for

complete height data.

8" Standard VerticalFixture with Emergency

Option (frame: CM8)

9 3/4"(248 mm)

8 3/4"(222 mm)

8 7/16"(214 mm)

10 1/2"(267 mm)

10 1/4"(260 mm)

17 3/16"(436 mm)

15"(381 mm)

7/8"

(22 mm)RemoteOption

IntegralOption

12 19/32"(320 mm)

9 13/32"(239 mm)

6 5/8"(168 mm)

9"(229 mm)

7 1/16"(179 mm)

2 1/2"(64 mm)

6 15/32"(164 mm)

21 9/32"(541 mm)

12 17/32"(417 mm)

4 3/4"(121 mm)

17 3/4"(451 mm)

17 1/2"(445 mm)

16 1/2"(419 mm)

9 3/4"(248 mm)

8 3/4"(222 mm)

8 7/16"(214 mm)

10 1/2"(267 mm)

14 7/8"(378 mm)

13 3/4"(350 mm)

10 1/4"(260 mm)

7/8"

(22 mm)

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

Ballast Options (choose one) Emergency OptionsElectronic Lutron Dimming Advance Dimming Radio (choose one)

Catalog Lamp 120-277V 347V 120V 277V 120V 277V Filter Fuse Integral RemoteNumber Designation U S3 DL11 DL21 DX12 DX22 RI F3 E4,5 ER5,6

FV13 (1) CFQ13W/G24q � � � � �

FV18 (1) CFQ18W/G24q, (1) CFM18W/GX24q � � � � � � � � � �

FV26/32/42 (1) CFQ26W/G24q, (1) CFM26W/GX24q,� � � � �(1) CFM32W/GX24q, (1) CFM42W/GX24q

FV26 (1) CFQ26W/G24q, (1) CFM26W/GX24q � � � � � � � � �

FV32 (1) CFM32W/GX24q � � � � � � � � �

FV42 (1) CFM42W/GX24q � � � � � � � � �

1Lutron Compact SE dimming, DL1 (120V), DL2 (277V). 3-wire system.2Advance Mark X dimming, DX1 (120V), DX2 (277V). 2-wire system.3Fuse kits are field installed. For large projects, consult factory for information on factory installation.4Use with emergency “E” option trims only. 5Not available for sloped ceiling systems, remodel systems or shower trims.6Initial lumens shown.

350lumens

350lumens

425lumens

600lumens

750lumens

8CFLReflectors

C O M P A C T F L U O R E S C E N T 8 "

V E R T I C A L

Slope ReflectorsClear Reflector, White Dome (for all slope trims) For use with CM8S Slope Housing only Ceiling cutout: 12" diameter

V85SR10 V85SR20 V85SR30Accommodates 5˚-15˚ Slope Accommodates 16˚-25˚ Slope Accommodates 26˚-35˚ Slope

V84Black Reflector V84EBlack, EmergencyV84SLBlack, Self-Flanged*

V83Gold Reflector V83EGold, EmergencyV83SLGold, Self-Flanged*

V85Low Iridescent Clear Reflector V85ELow Iridescent, EmergencyV85SLLow Iridescent, Self-Flanged*V85SLELow Iridescent, Self-Flanged*,Emergency

V86White Reflector V86EWhite, EmergencyV86SLWhite, Self-Flanged*

V85BLow Iridescent Reflector, Black Baffle V85BELow Iridescent, Black Baffle,Emergency

V87Wheat Reflector V87EWheat, EmergencyV87SLWheat, Self-Flanged*

V85WBLow Iridescent Reflector, White Baffle V85WBELow Iridescent, White Baffle,Emergency

V85SWRPolycarbonate Shower TrimNot available with Emergency Option

VW85Low Iridescent Clear Reflector,Single Wall Wash (shown) VW85ELow Iridescent, Single Wall Wash,EmergencyVW85SLLow Iridescent, Single Wall Wash,Self-Flanged*

VW83Gold Reflector,Single Wall Wash (shown)VW83EGold, Single Wall Wash, EmergencyVWD83Gold, Double Wall WashVWD83EGold, Double Wall Wash, Emergency

VWD85Low Iridescent Clear Reflector,Double Wall Wash (shown)VWD85ELow Iridescent, Double Wall Wash,Emergency

White Baffle, Glass Lens InsertV85WBCClear LensV85WBFFresnel LensV85WBPC73 Prismatic Lens

White Splay, Glass Lens InsertV86CClear LensV86FFresnel LensV86PC73 Prismatic Lens

Clear Cone, Glass Lens InsertV85CClear LensV85FFresnel LensV85PC73 Prismatic Lens

Black Baffle, Glass Lens InsertV85BCClear LensV85BFFresnel LensV85BPC73 Prismatic Lens

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM8S-FV26/32/42URI-V85SR20-CH241

ww

w.caprilighting.com

23

V85XBLow Iridescent Cross Baffle ReflectorV85XBELow Iridescent Cross Baffle Reflector, Emergency

8 CFL C O M P A C T F L U O R E S C E N T 8 "

H O R I Z O N T A L

CM8Metal frame with 8"aperture.The 8" ring onthe CM8 canbe replaced with a 6" ring(ordered separately) in thefield if needed.

Frame

Electrical

CM8RRemodel metal frame for 8"aperture applications.Not for use with emergency options.

CM8SSlope ceiling metal frame for 8"aperture applications.For use with slope ceiling reflectors only.

Not for use with integral emergency options.

Requires ceiling cutout of 12".For use in 24" on center joist construction only.

24

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

6 5/8"(168 mm)

9"(229 mm)

12 19/32"(320 mm)

9 13/32"(239 mm)

7 1/16"(179 mm)

2 1/2"(64 mm)

6 15/32"(164 mm)

17 1/2"(445 mm)

17 3/4"(451 mm)

16 1/2"(419 mm)

21 9/32"(541 mm)

12 17/32"(417 mm)

4 3/4"(121 mm)

8" Slope Ceiling Metal Frame (frame: CM8S)

Max Height: 10-7/16" —see spec sheet for

complete height data.

8" Remodel MetalFrame (frame: CM8R)

Ballast Options (choose one) Emergency OptionsElectronic Lutron Dimming Advance Dimming Radio (choose one)

Catalog Lamp 120-277V 347V 120V 277V 120V 277V Filter Fuse Integral RemoteNumber Designation U S3 DL11 DL21 DX12 DX22 RI F3 E4,5 ER5,6

F113 (1) CFQ13W/G24q � � � � �

F118 (1) CFQ18W/G24q, (1) CFM18W/GX24q � � � � � � � � � �

F126/32/42 (1) CFQ26W/G24q, (1) CFM26W/GX24q,� � � � �(1) CFM32W/GX24q, (1) CFM42W/GX24q

F126 (1) CFQ26W/G24q, (1) CFM26W/GX24q � � � � � � � � �

F132 (1) CFM32W/GX24q � � � � � � � � �

F142 (1) CFM42W/GX24q � � � � � � � � �

1Lutron Compact SE dimming, DL1 (120V), DL2 (277V). 3-wire system.2Advance Mark X dimming, DX1 (120V), DX2 (277V). 2-wire system.3Fuse kits are field installed. For large projects, consult factory for information on factory installation.4Use with emergency “E” option trims only. 5Not available for sloped ceiling systems, remodel systems or shower trims.6Initial lumens shown.

13 3/4"(350 mm)

10 1/4"(260 mm)

14 7/8"(378 mm)

7"(178 mm)

9 3/4"(248 mm)

8 3/4"(222 mm)

8 7/16"(214 mm)

7/8"(22 mm)

10 1/4"(260 mm)

17 3/16"(436 mm)

15"(381 mm)

9 3/4"(248 mm)

8 3/4"(222 mm)

8 7/16"(214mm)

8 3/8"(213 mm)

7/8"(22 mm)

7"(178 mm)

RemoteOption

IntegralOption

8" Standard Horizontal Fixture (frame: CM8)

350lumens

350lumens

425lumens

600lumens

750lumens

8" Standard HorizontalFixture with Emergency

Option (frame: CM8)

8CFLReflectors

C O M P A C T F L U O R E S C E N T 8 "

H O R I Z O N T A L

Slope ReflectorsClear Reflector, White Dome (for all slope trims) For use with CM8S Slope Housing only Ceiling cutout: 12" diameter

H85SR10 H85SR20 H85SR30Accommodates 5˚-15˚ Slope Accommodates 16˚-25˚ Slope Accommodates 26˚-35˚ Slope

H85Low Iridescent Clear Reflector H85ELow Iridescent, EmergencyH85SLLow Iridescent, Self-Flanged*H85SLELow Iridescent, Self-Flanged*,Emergency

H83Gold Reflector H83EGold, EmergencyH83SLGold, Self-Flanged*

H86White Reflector H86EWhite, EmergencyH86SLWhite, Self-Flanged*

H87Wheat Reflector H87EWheat, EmergencyH87SLWheat, Self-Flanged*

HWD83Gold Reflector,Double Wall WashHWD83EGold, Double Wall Wash,Emergency

HW83Gold Reflector,Single Wall WashHW83EGold Reflector, Single Wall Wash,Emergency

HW85Low Iridescent Clear Reflector,Single Wall Wash (shown)HW85ELow Iridescent, Single Wall Wash,EmergencyHW85SLLow Iridescent, Single Wall Wash,Self-Flanged*

HWD85Low Iridescent Clear Reflector,Double Wall WashHWD85ELow Iridescent, Double Wall Wash, Emergency

H85SWRPolycarbonate Shower TrimNot available with Emergency Option

H85XBLow Iridescent Cross Baffle Reflector H85XBELow Iridescent Cross Baffle Reflector, Emergency

Black Baffle, Glass Lens InsertH85BCClear LensH85BFFresnel LensH85BPC73 Prismatic Lens

Clear Cone, Glass Lens InsertH85CClear LensH85FFresnel LensH85PC73 Prismatic Lens

White Splay, Glass Lens InsertH86CClear LensH86FFresnel LensH86PC73 Prismatic Lens

White Baffle, Glass Lens InsertH85WBCClear LensH85WBFFresnel LensH85WBPC73 Prismatic Lens

H85WBLow Iridescent Reflector,White Baffle H85WBELow Iridescent, White Baffle,Emergency

H85BLow Iridescent Reflector,Black Baffle H85BELow Iridescent, Black Baffle,Emergency

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM8-F132S3RI-H85B-BH31

ww

w.caprilighting.com

25

8 CFL C O M P A C T F L U O R E S C E N T 8 "

H O R I Z O N T A L 2 - L A M P

CM8Metal frame with 8"aperture.The 8" ring onthe CM8 canbe replaced with a 6" ring(ordered separately) in thefield if needed.

Frame

Electrical

CM8RRemodel metal frame for 8"aperture applications.Not for use with emergency options.

CM8SSlope ceiling metal frame for 8"aperture applications.For use with slope ceiling reflectors only.

Not for use with integral emergency options.

Requires ceiling cutout of 12".For use in 24" on center joist construction only.

26

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

13 3/4"(350 mm)

10 1/4"(260 mm)

14 7/8"(378 mm)

7"(178 mm)

9 3/4"(248 mm)

8 3/4"(222 mm)

8 7/16"(214 mm)

7/8"(22 mm)

10 1/4"(260 mm)

17 3/16"(436 mm)

15"(381 mm)

9 3/4"(248 mm)

8 3/4"(222 mm)

8 7/16"(214mm)

8 3/8"(213 mm)

7/8"(22 mm)

7"(178 mm)

RemoteOption

IntegralOption

6 5/8"(168 mm)

9"(229 mm)

12 19/32"(320 mm)

9 13/32"(239 mm)

7 1/16"(179 mm)

2 1/2"(64 mm)

6 15/32"(164 mm)

17 1/2"(445 mm)

17 3/4"(451 mm)

16 1/2"(419 mm)

21 9/32"(541 mm)

12 17/32"(417 mm)

4 3/4"(121 mm)

8" Standard Horizontal Fixture (frame: CM8)

8" Standard HorizontalFixture with Emergency

Option (frame: CM8)

8" Slope Ceiling Metal Frame (frame: CM8S)

Max Height: 10-7/16"(see spec sheet for

complete height data)

8" Remodel MetalFrame (frame: CM8R)

Ballast Options (choose one) EmergencyLutron Advance Options

Electronic Dimming Dimming Dual-Level Radio (choose one)

Catalog Lamp 120-277V 347V 120V 277V 120V 277V Switching Filter Fuse Integral RemoteNumber Designation U S3 DL11 DL21 DX12 DX22 DB RI F3 E4,5 ER5,6

F213 (2) CFQ13W/G24q � � � � � � �

F218 (2) CFQ18W/G24q, (2) CFM18W/GX24q � � � � � � � � � � �

F226/32/42 (2) CFQ26W/G24q, (2) CFM26W/GX24q,� � � � � �(2) CFM32W/GX24q, (2) CFM42W/GX24q

F226 (2) CFQ26W/G24q, (2) CFM26W/GX24q � � � � � � � � � �

F232 (2) CFM32W/GX24q � � � � � � � � � �

F242 (2) CFM42W/GX24q � � � � � � � � � �

1Lutron Compact SE dimming, DL1 (120V), DL2 (277V). 3-wire system.2Advance Mark X dimming, DX1 (120V), DX2 (277V). 2-wire system.3Fuse kits are field installed. For large projects, consult factory for information on factory installation.4Use with emergency “E” option trims only. 5Not available for slope ceiling, remodel systems or shower trims.6Initial lumens shown.

350lumens

350lumens

425lumens

600lumens

750lumens

8CFLReflectors

C O M P A C T F L U O R E S C E N T 8 "

H O R I Z O N T A L 2 - L A M P

Slope ReflectorsClear Reflector, White Dome (for all slope trims) For use with CM8S Slope Housing only Ceiling cutout: 12" diameter

H85SR10 H85SR20 H85SR30Accommodates 5˚-15˚ Slope Accommodates 16˚-25˚ Slope Accommodates 26˚-35˚ Slope

H85Low Iridescent Clear Reflector H85ELow Iridescent, EmergencyH85SLLow Iridescent, Self-Flanged*H85SLELow Iridescent, Self-Flanged*,Emergency

H83Gold Reflector H83EGold, EmergencyH83SLGold, Self-Flanged*

H86White Reflector H86EWhite, EmergencyH86SLWhite, Self-Flanged*

H87Wheat Reflector H87EWheat, EmergencyH87SLWheat, Self-Flanged*

HWD83Gold Reflector,Double Wall WashHWD83EGold, Double Wall Wash,Emergency

HW83Gold Reflector,Single Wall WashHW83EGold, Single Wall Wash,Emergency

HW85Low Iridescent Clear Reflector,Single Wall Wash (shown)HW85ELow Iridescent, Single Wall Wash,EmergencyHW85SLLow Iridescent, Single Wall Wash,Self-Flanged*

HWD85Low Iridescent Clear Reflector,Double Wall WashHWD85ELow Iridescent, Double Wall Wash, Emergency

H85SWRPolycarbonate Shower TrimNot available with Emergency Option

H85XBLow Iridescent Cross Baffle Reflector H85XBELow Iridescent Cross Baffle Reflector, Emergency

Black Baffle, Glass Lens InsertH85BCClear LensH85BFFresnel LensH85BPC73 Prismatic Lens

Clear Cone, Glass Lens InsertH85CClear LensH85FFresnel LensH85PC73 Prismatic Lens

White Splay, Glass Lens InsertH86CClear LensH86FFresnel LensH86PC73 Prismatic Lens

White Baffle, Glass Lens InsertH85WBCClear LensH85WBFFresnel LensH85WBPC73 Prismatic Lens

H85WBLow Iridescent Reflector,White Baffle H85WBELow Iridescent, White Baffle,Emergency

H85BLow Iridescent Reflector,Black Baffle H85BELow Iridescent, Black Baffle,Emergency

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM8-F226/32/42UDBRIER-H85WB-CH241

ww

w.caprilighting.com

27

8 INC I N C A N D E S C E N T 8 "

V E R T I C A L

Frame

Electrical

28

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

Maximum Wattage

CatalogNumber Incandescent Lamp Type V85SWR Reflector Typical Reflectors V84 Black Reflector Lensed Reflectors

A300 A 150W 200W 100W 150W

PAR30 75W 75W 75W 75W

R/BR30 100W 100W 100W 100W

PAR38 100W 250W 150W 100W

R/BR40 100W 300W 150W 100W

CM8Metal frame with 8"aperture.The 8" ring onthe CM8 canbe replaced with a 4" or 6"ring (ordered separately) inthe field if needed.

CM8RRemodel metal frame for8"aperture applications.

CM8SSlope ceiling metal frame for 8"aperture applications.For use with slope ceiling reflectors only.

Requires ceiling cutout of 12".For use in 24" on center joist construction only.

10 1/2"(267 mm)

8 7/8"(246 mm)

8 3/4"(222 mm)

8 7/16"(214 mm)

7/8"(22 mm)

15 3/4"(400 mm)

13 3/4"(350 mm)

10 1/4"(260 mm)

12 19/32"(320 mm)

9 13/32"(239 mm)

7 1/16"(179 mm)

2 1/2"(64 mm)

6 15/32"(164 mm)

6 5/8"(168 mm)

9"(229 mm)

8" Standard IncandescentFixture (frame: CM8)

8" Remodel MetalFrame (frame: CM8R)

8" Slope Ceiling Metal Frame (frame: CM8S))

Max Height: 10-7/16"(see spec sheet for

complete height data)

17 1/2"(445 mm)

17 3/4"(451 mm)

16 1/2"(419 mm)

21 9/32"(541 mm)

12 17/32"(417 mm)

4 3/4"(121 mm)

8INCReflectors

I N C A N D E S C E N T 8 "

V E R T I C A L

V84Black Reflector V84SLBlack, Self-Flanged*

V83Gold ReflectorV83SLGold, Self-Flanged*

V85Low Iridescent Clear Reflector V85SLLow Iridescent, Self-Flanged*

V86White Reflector V86SLWhite, Self-Flanged*

V85BLow Iridescent Reflector, Black Baffle

V87Wheat Reflector V87SLWheat, Self-Flanged*

V85WBLow Iridescent Reflector, White Baffle

V85SWRPolycarbonate Shower Trim

VW85Low Iridescent Clear Reflector,Single Wall Wash (shown) VW85SLLow Iridescent, Single Wall Wash,Self-Flanged*

VW83Gold Reflector, Single Wall Wash (shown)VWD83Gold, Double Wall Wash

VWD85Low Iridescent Clear Reflector,Double Wall Wash

White Baffle, Glass Lens InsertV85WBCClear LensV85WBFFresnel LensV85WBPC73 Prismatic Lens

White Splay, Glass Lens InsertV86CClear LensV86FFresnel LensV86PC73 Prismatic Lens

Clear Cone, Glass Lens InsertV85CClear LensV85FFresnel LensV85PC73 Prismatic Lens

Black Baffle, Glass Lens InsertV85BCClear LensV85BFFresnel LensV85BPC73 Prismatic Lens

Denotes c/UL wet location listing. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM8-A300-VWD85-BH11

ww

w.caprilighting.com

29

Slope ReflectorsClear Reflector, White Dome (for all slope trims) For use with CM8S Slope Housing only Ceiling cutout: 12" diameter

V85SR10 V85SR20 V85SR30Accommodates 5˚-15˚ Slope Accommodates 16˚-25˚ Slope Accommodates 26˚-35˚ Slope

V85XBLow Iridescent Cross Baffle Reflector

Electronic Ballasts (standard)1Magnetic Ballast Options Fuse(choose one)

120/277V 120/347V Options3 EmergencyCatalog Lamp 120V 277V 120/277V Consult Factory See Chart

RestrikeNumber Designation EB1 EB2 EBU for availability C2

Page 45 E4,5,9

ELECTRONIC ONLY

M206 CMH20/PAR30, CMH20/PAR20 (ANSI M156) � � N/A � �

ML207 CMH20/PAR30, CMH20/PAR20 (ANSI M156) � � N/A � �

ELECTRONIC / MAGNETIC COMPATIBLE

M356,8 CMH35/PAR30, CMH35/PAR20 (ANSI M130) � Available � � �

ML357,8 CMH35/PAR30, CMH35/PAR20 (ANSI M130) � Available � � �

M506 CMH50/ED-17P/C/MED, MP50/ED-17/C/MED� Available � � �(ANSI M110, M148)

ML507 CMH50/ED-17/C/MED, M50/ED-17/C/MED� Available � � �(ANSI M110, M148)

M706 CMH70/PAR 38, CMH70/PAR 30, CMH70/ED-17P/C/MED, � Available � � �MP70/ED-17/C/MED (ANSI M98, M143)

ML707 CMH70/PAR 38, CMH70/PAR 30, CMH70/ED-17/C/MED,� Available � � �M70/ED-17/C/MED (ANSI M98, M143)

M1006 CMH100/PAR 38, CMH100/ED-17P/C/MED, � Available � � �MP100/ED-17/C/MED (ANSI M90, M140)

ML1007 CMH100/PAR 38, CMH100/ED-17/C/MED, � Available � � �M100/ED-17/C/MED (ANSI M90, M140)

M1506 CMH150/PAR 38, CMH150/ED-17P/C/MED, � Canada Only � � �MP150/ED-17/C/MED (ANSI M102, M142)

ML1507 CMH150/PAR 38, CMH150/ED-17/C/MED, � Canada Only � � �M150/ED-17/C/MED (ANSI M102, M142)

1Effective January 1, 2009, Electronic ballasts are standard to conform to EISA. Consult factory for magnetic availability.2347V available only on magnetic ballasts.3HID Fuse kits vary depending on wattage and voltage. Refer to chart on page 45 to determine the correct fuse kit for your application.4Use T4 quartz bayonet base lamps.5Use with emergency "E" option trims only.6Use open rated lamps only.7For use with lensed trims only. 8Actual lamp wattage is 39 watts.9Not available for sloped ceiling systems.

8 HID M E T A L H A L I D E 8 "

V E R T I C A L

CM8Metal frame with 8"aperture.The 6" ring onthe CM8 canbe replaced with a 4" or 6"ring (ordered separately) inthe field if needed.

Frame

Electrical

30

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

CM8SSlope ceiling metal frame for 8"aperture applications.For use with slope ceiling reflectors only.

Not for use with integral emergency options.

Requires ceiling cutout of 12".For use in 24" on center joist construction only.

17 1/2"(445 mm)

17 3/4"(451 mm)

16 1/2"(419 mm)

21 9/32"(541 mm)

12 17/32"(417 mm)

4 3/4"(121 mm)

9 3/4"(248 mm)

8 3/4"(222 mm)

8 7/16"(214 mm)

10 1/2"(267 mm)

14 7/8"(378 mm)

13 3/4"(350 mm)

10 1/4"(260 mm)

7/8"

(22 mm)

9 3/4"(248 mm)

8 3/4"(222 mm)

8 7/16"(214 mm)

10 1/2"(267 mm)

14 7/8"(378 mm)

13 3/4"(350 mm)

10 1/4"(260 mm)

7/8"

(22 mm)

8" Standard HID Fixture(frame: CM8)

8" Standard HID Fixture withEmergency Option (frame: CM8)

8" Slope Ceiling Metal Frame (frame: CM8S)

Max Height: 14 -1/16" (see spec sheet for complete height data)

V84Black Reflector V84EBlack, EmergencyV84SLBlack, Self-Flanged*

V83Gold ReflectorV83EGold, EmergencyV83SLGold, Self-Flanged*

V85Low Iridescent Clear Reflector V85SELow Iridescent, Emergency V85SLLow Iridescent, Self-Flanged*V85SLELow Iridescent, Self-Flanged*,Emergency

V86White ReflectorV86EWhite, EmergencyV86SLWhite, Self-Flanged*

V85BLow Iridescent,Reflector,Black Baffle V85BELow Iridescent, Black Baffle,Emergency

V87Wheat ReflectorV87EWheat, EmergencyV87SLWheat, Self-Flanged*

V85WBLow Iridescent Reflector, White BaffleV85WBELow Iridescent, White Baffle,Emergency

V85XBLow Iridescent Cross Baffle ReflectorV85XBELow Iridescent Cross Baffle Reflector, Emergency

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM8S-M39EBU-V85SR20-CH241

8HIDReflectors

M E T A L H A L I D E 8 "

V E R T I C A Lw

ww

.caprilighting.com

31

VW83Gold Reflector,Single Wall WashVW83EGold Reflector,Single Wall Wash, Emergency

VWD83Gold Reflector,Double Wall WashVWD83EGold Reflector,Double Wall Wash, Emergency

VWD85Low Iridescent Clear Reflector,Double Wall WashVWD85ELow Iridescent, Double Wall Wash, Emergency

VW85Low Iridescent Clear Reflector,Single Wall Wash (shown)VW85ELow Iridescent, Single Wall Wash,EmergencyVW85SLLow Iridescent, Single Wall Wash,Emergency, Self-Flanged

Black Baffle, Glass Lens InsertV85BCClear LensV85BFFresnel LensV85BPC73 Prismatic Lens

Clear Cone, Glass Lens InsertV85CClear LensV85FFresnel LensV85PC73 Prismatic Lens

White Splay, Glass Lens InsertV86CClear LensV86FFresnel LensV86PC73 Prismatic Lens

White Baffle, Glass Lens InsertV85WBCClear LensV85WBFFresnel LensV85WBPC73 Prismatic Lens

Slope ReflectorsClear Reflector, White Dome (for all slope trims) For use with CM8S Slope Housing only Ceiling cutout: 12" diameter

V85SR10 V85SR20 V85SR30Accommodates 5˚-15˚ Slope Accommodates 16˚-25˚ Slope Accommodates 26˚-35˚ Slope

10 CFL C O M P A C T F L U O R E S C E N T 1 0 "

V E R T I C A L

CM10Metal frame with 10"aperture.

Frame

Electrical

CM10RRemodel metal frame for10"aperture applications.Not for use with emergency options.

CM10SSlope ceiling metal frame for 10"aperture applications.For use with slope ceiling reflectors only.

Not for use with integral emergency options.

Requires ceiling cutout of 16". For use in 24" on center joist construction only.

For use in 2" x 4" ceiling tile systems only.

32

10" Standard Vertical Fixture (frame: CM10)

10" Remodel MetalFrame (frame: CM10R)

15 1/32"(389mm)

11 3/8"(289mm)

16 1/2"(419 mm)

17 3/8"(441 mm)

11 1/8"(283 mm)

10 1/16"(256 mm)

9 7/8"(251 mm)

7/8"(22 mm)

16 1/16"(408 mm)

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

7 1/4"(184 mm)

10 7/16"(265 mm)

7 1/16"(229 mm) 2 1/2"

(64 mm)

6 15/16"(164 mm)

10 27/32"(275 mm)

14 1/32"(356 mm)

Ballast Options (choose one) Emergency OptionsElectronic Lutron Dimming Advance Dimming Radio (choose one)

Catalog Lamp 120-277V 347V 120V 277V 120V 277V Filter Fuse Integral RemoteNumber Designation U S3 DL11 DL21 DX12 DX22 RI F3 E4,5 ER5,6

FV26/32/42 (1) CFQ26W/G24q, (1) CFM26W/GX24q,� � � � �(1) CFM32W/GX24q, (1) CFM42W/GX24q

FV26 (1) CFQ26W/G24q, (1) CFM26W/GX24q � � � � � � � � �

FV32 (1) CFM32W/GX24q � � � � � � � � �

FV42 (1) CFM42W/GX24q � � � � � � � � �

FV57 (1) CFM57W/GX24q � � � � � � � �

1Lutron Compact SE dimming, DL1 (120V), DL2 (277V). 3-wire system.2Advance Mark X dimming, DX1 (120V), DX2 (277V). 2-wire system.3Fuse kits are field installed. For large projects, consult factory for information on factory installation.4Use with emergency “E” option trims only. 5Not available for sloped ceiling systems or remodel systems.6Initial lumens shown.

15 3/8"(391 mm)

16 1/2"(419 mm)

17 3/8"(441 mm)

11 1/8"(283 mm)

10 1/16"(256 mm)

9 7/8"(251 mm)

16 1/16"(408 mm)

7/8"(22 mm)

10" Standard VerticalFixture with Emergency

Option (frame: CM10)

425lumens

600lumens

750lumens

1160lumens

RemoteOption

16 13/32"(417 mm)

21 9/16"(548 mm)

19"(483 mm)

4 3/4"(121 mm)

10" Slope Ceiling Metal Frame (frame: CM10S)

Max Height: 21-11/16"(see spec sheet for

complete height data)

10CFLReflectors

C O M P A C T F L U O R E S C E N T 1 0 "

V E R T I C A L

Slope ReflectorsClear Reflector, White Dome (for all slope trims) For use with CM10S Slope Housing only Ceiling cutout: 16" diameter

V105SR10 V105SR20 V105SR30Accommodates 5˚-15˚ Slope Accommodates 16˚-25˚ Slope Accommodates 26˚-35˚ Slope

V105SR40Accommodates 36˚-45˚ Slope

V104Black Reflector V104EBlack, EmergencyV104SLBlack, Self-Flanged*

V103Gold Reflector V103EGold, EmergencyV103SLGold, Self-Flanged*

V105Low Iridescent Clear Reflector V105ELow Iridescent, EmergencyV105SLLow Iridescent, Self-Flanged*

V106White Reflector V106EWhite, EmergencyV106SLWhite, Self-Flanged*

V105BLow Iridescent Reflector, Black Baffle V105BELow Iridescent, Black Baffle,Emergency

V107Wheat Reflector V107EWheat, EmergencyV107SLWheat, Self-Flanged*

V105WBLow Iridescent Reflector, White Baffle V105WBELow Iridescent, White Baffle,Emergency

VW105Low Iridescent Clear Reflector,Single Wall WashVW105ELow Iridescent,Single Wall Wash, Emergency

VW103Gold Reflector,Single Wall WashVW103EGold, Single Wall Wash,Emergency

VWD103Gold Reflector,Double Wall WashVWD103EGold, Double Wall Wash,Emergency

VWD105Low Iridescent Clear Reflector,Double Wall WashVWD105ELow Iridescent,Double Wall Wash, Emergency

Black Baffle, Glass Lens InsertV105BCClear LensV105BFFresnel LensV105BPC73 Prismatic Lens

Clear Cone, Glass Lens InsertV105CClear LensV105FFresnel LensV105PC73 Prismatic Lens

White Splay, Glass Lens InsertV106CClear LensV106FFresnel LensV106PC73 Prismatic Lens

White Baffle, Glass Lens InsertV105WBCClear LensV105WBFFresnel LensV105WBPC73 Prismatic Lens

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM10-FV42DL2E-V105BE-BH31

ww

w.caprilighting.com

33

CFL C O M P A C T F L U O R E S C E N T 1 0 "

H O R I Z O N T A L

CM10Metal frame with 10"aperture.

Frame

Electrical

CM10RRemodel metal frame for10"aperture applications.Not for use with emergency options.

CM10SSlope ceiling metal frame for 10"aperture applications.For use with slope ceiling reflectors only.

Not for use with integral emergency options.

Requires ceiling cutout of 16". For use in 24" on center joist construction only.

For use in 2" x 4" ceiling tile systems only.

34

10" Standard Horizontal Fixture (frame: CM10)

11 1/8"(283 mm)

10 1/16"(256 mm)

9 13/16"(249 mm)

7/8"(22 mm)

8 3/8"(213mm)

15 1/32"(389mm)

11 3/8"(289mm)

16 1/2"(419 mm)

17 3/4"(451 mm)

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

7 1/4"(184 mm)

10 7/16"(265 mm)

7 1/16"(229 mm) 2 1/2"

(64 mm)

6 15/16"(164 mm)

10 27/32"(275 mm)

14 1/32"(356 mm)

10" Remodel MetalFrame (frame: CM10R)

11 1/8"(283 mm)

10 1/16"(256 mm)

9 13/16"(249 mm)

7/8"(22 mm)

8 3/8"(213mm)

15 1/16"(383mm)

16 1/2"(419 mm)

21 11/16"(551 mm)

10" Standard HorizontalFixture with Emergency

Option (frame: CM10)

Ballast Options (choose one) Emergency OptionsElectronic Lutron Dimming Advance Dimming Radio (choose one)

Catalog Lamp 120-277V 347V 120V 277V 120V 277V Filter Fuse Integral RemoteNumber Designation U S3 DL11 DL21 DX12 DX22 RI F3 E4,5 ER5,6

F126/32/42 (1) CFQ26W/G24q, (1) CFM26W/GX24q,� � � � �(1) CFM32W/GX24q, (1) CFM42W/GX24q

F126 (1) CFQ26W/G24q, (1) CFM26W/GX24q � � � � � � � � �

F132 (1) CFM32W/GX24q � � � � � � � � �

F142 (1) CFM42W/GX24q � � � � � � � � �

1Lutron Compact SE dimming, DL1 (120V), DL2 (277V). 3-wire system.2Advance Mark X dimming, DX1 (120V), DX2 (277V). 2-wire system.3Fuse kits are field installed. For large projects, consult factory for information on factory installation.4Use with emergency “E” option trims only. 5Not available for sloped ceiling systems or remodel systems.6Initial lumens shown.

10

425lumens

600lumens

750lumens

16 13/32"(417 mm)

21 9/16"(548 mm)

19"(483 mm)

4 3/4"(121 mm)

10" Slope Ceiling Metal Frame (frame: CM10S)

Max Height: 14-1/8"(see spec sheet for

complete height data)

RemoteOption

CFLReflectors

C O M P A C T F L U O R E S C E N T 1 0 "

H O R I Z O N T A L

Slope ReflectorsClear Reflector, White Dome (for all slope trims) For use with CM10S Slope Housing only Ceiling cutout: 16" diameter

H105SR10 H105SR20 H105SR30Accommodates 5˚-15˚ Slope Accommodates 16˚-25˚ Slope Accommodates 26˚-35˚ SlopeH105SR40Accommodates 36˚-45˚ Slope

H105Low Iridescent Clear Reflector H105ELow Iridescent, EmergencyH105SLLow Iridescent, Self-Flanged*

H103Gold Reflector H103EGold, EmergencyH103SLGold, Self-Flanged*

H106White Reflector H106EWhite, EmergencyH106SLWhite, Self-Flanged*

H107Wheat Reflector H107EWheat, EmergencyH107SLWheat, Self-Flanged*

HWD103Gold Reflector,Double Wall WashHWD103EGold, Double Wall Wash,Emergency

HW103Gold Reflector,Single Wall WashHW103EGold, Single Wall Wash,Emergency

HW105Low Iridescent Clear Reflector,Single Wall WashHW105ELow Iridescent, Single Wall Wash,Emergency

HWD105Low Iridescent Clear Reflector,Double Wall WashHWD105ELow Iridescent,Double Wall Wash, Emergency

Black Baffle, Glass Lens InsertH105BCClear LensH105BFFresnel LensH105BPC73 Prismatic Lens

Clear Cone, Glass Lens InsertH105CClear LensH105FFresnel LensH105PC73 Prismatic Lens

White Splay, Glass Lens InsertH106CClear LensH106FFresnel LensH106PC73 Prismatic Lens

White Baffle, Glass Lens InsertH105WBCClear LensH105WBFFresnel LensH105WBPC73 Prismatic Lens

H105WBLow Iridescent Reflector,White Baffle H105WBELow Iridescent, White Baffle,Emergency

H105BLow Iridescent Reflector,Black Baffle H105BELow Iridescent, Black Baffle,Emergency

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM10-F126/32/42U-HWD105-CH241

ww

w.caprilighting.com

35

10

CFL C O M P A C T F L U O R E S C E N T 1 0 "

H O R I Z O N T A L 2 - L A M P

CM10Metal frame with 10"aperture.

Frame

Electrical

CM10RRemodel metal frame for10"aperture applications.Not for use with emergency options.

CM10SSlope ceiling metal frame for 10"aperture applications.For use with slope ceiling reflectors only.

Not for use with integral emergency options.

Requires ceiling cutout of 16". For use in 24" on center joist construction only.

For use in 2" x 4" ceiling tile systems only.

36

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

7 1/4"(184 mm)

10 7/16"(265 mm)

7 1/16"(229 mm) 2 1/2"

(64 mm)

6 15/16"(164 mm)

10 27/32"(275 mm)

14 1/32"(356 mm)

10" Remodel MetalFrame (frame: CM10R)

Ballast Options (choose one) EmergencyLutron Advance Options

Electronic Dimming Dimming Dual-Level Radio (choose one)

Catalog Lamp 120-277V 347V 120V 277V 120V 277V Switching Filter Fuse Integral RemoteNumber Designation U S3 DL11 DL21 DX12 DX22 DB RI F3 E4,5 ER5,6

F226/32/42 (2) CFQ26W/G24q, (2) CFM26W/GX24q,� � � � � �(2) CFM32W/GX24q, (2) CFM42W/GX24q

F226 (2) CFQ26W/G24q, (2) CFM26W/GX24q � � � � � � � � � �

F232 (2) CFM32W/GX24q � � � � � � � � � �

F242 (2) CFM42W/GX24q � � � � � � � � � �

1Lutron Compact SE dimming, DL1 (120V), DL2 (277V). 3-wire system.2Advance Mark X dimming, DX1 (120V), DX2 (277V). 2-wire system.3Fuse kits are field installed. For large projects, consult factory for information on factory installation.4Use with emergency “E” option trims only. 5Not available for sloped ceiling systems or remodel systems.6Initial lumens shown.

10

425lumens

600lumens

750lumens

11 1/8"(283 mm)

10 1/16"(256 mm)

9 13/16"(249 mm)

7/8"(22 mm)

8 3/8"(213mm)

15 1/32"(389mm)

11 3/8"(289mm)

16 1/2"(419 mm)

17 3/4"(451 mm)

11 1/8"(283 mm)

10 1/16"(256 mm)

9 13/16"(249 mm)

7/8"(22 mm)

8 3/8"(213mm)

15 1/16"(383mm)

16 1/2"(419 mm)

21 11/16"(551 mm)

16 13/32"(417 mm)

21 9/16"(548 mm)

19"(483 mm)

4 3/4"(121 mm)

RemoteOption

10" Standard Horizontal Fixture (frame: CM10)

10" Standard HorizontalFixture with Emergency

Option (frame: CM10)

10" Slope Ceiling Metal Frame (frame: CM10S)

Max Height: 14-1/8"(see spec sheet for

complete height data)

CFLC O M P A C T F L U O R E S C E N T 1 0 "

H O R I Z O N T A L 2 - L A M P

Slope ReflectorsClear Reflector, White Dome (for all slope trims) For use with CM10S Slope Housing only Ceiling cutout: 16" diameter

H105SR10 H105SR20 H105SR30Accommodates 5˚-15˚ Slope Accommodates 16˚-25˚ Slope Accommodates 26˚-35˚ SlopeH105SR40Accommodates 36˚-45˚ Slope

H105Low Iridescent Clear Reflector H105ELow Iridescent, EmergencyH105SLLow Iridescent, Self-Flanged*

H103Gold Reflector H103EGold, EmergencyH103SLGold, Self-Flanged*

H106White Reflector H106EWhite, EmergencyH106SLWhite, Self-Flanged*

H107Wheat Reflector H107EWheat, EmergencyH107SLWheat, Self-Flanged*

HWD103Gold Reflector,Double Wall WashHWD103EGold, Double Wall Wash,Emergency

HW103Gold Reflector,Single Wall WashHW103EGold, Single Wall Wash,Emergency

HW105Low Iridescent Clear Reflector,Single Wall WashHW105ELow Iridescent, Single Wall Wash,Emergency

HWD105Low Iridescent Clear Reflector,Double Wall WashHWD105ELow Iridescent, Double Wall Wash, Emergency

Black Baffle, Glass Lens InsertH105BCClear LensH105BFFresnel LensH105BPC73 Prismatic Lens

Clear Cone, Glass Lens InsertH105CClear LensH105FFresnel LensH105PC73 Prismatic Lens

White Splay, Glass Lens InsertH106CClear LensH106FFresnel LensH106PC73 Prismatic Lens

White Baffle, Glass Lens InsertH105WBCClear LensH105WBFFresnel LensH105WBPC73 Prismatic Lens

H105WBLow Iridescent Reflector,White Baffle H105WBELow Iridescent, White Baffle,Emergency

H105BLow Iridescent Reflector,Black Baffle H105BELow Iridescent, Black Baffle,Emergency

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM10S-F226S3RI-H105SR30-BH11

Reflectors

ww

w.caprilighting.com

37

10

CFL C O M P A C T F L U O R E S C E N T 1 0 "

H O R I Z O N T A L 3 - L A M P

CM10Metal frame with 10"aperture.Compact fluorescent triple lamphorizontal fixtures are availablefor 10” apertures only.

Frame

Electrical

38

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

11 1/8"(283 mm)

10 1/16"(256 mm)

9 13/16"(249 mm)

7/8"(22 mm)

8 3/8"(213mm)

15 1/16"(383mm)

16 1/2"(419 mm)

21 11/16"(551 mm)

10" Standard HorizontalFixture with Emergency

Option (frame: CM10)

10

Ballast Options (choose one) EmergencyLutron Advance Options

Electronic Dimming Dimming Dual-Level Radio (choose one)

Catalog Lamp 120-277V 347V 120V 277V 120V 277V Switching Filter Fuse Integral RemoteNumber Designation U S3 DL11 DL21 DX12 DX22 DB3 RI F4 E5,6 ER6,7

F326/32/42 (3) CFQ26W/G24q, (3) CFM26W/GX24q,� � � � � �(3) CFM32W/GX24q, (3) CFM42W/GX24q

F326 (3) CFQ26W/G24q, (3) CFM26W/GX24q � � � � � � � � � �

F332 (3) CFM32W/GX24q � � � � � � � � � �

F342 (3) CFM42W/GX24q � � � � � � � � � �

1Lutron Compact SE dimming, DL1 (120V), DL2 (277V). 3-wire system.2Advance Mark X dimming, DX1 (120V), DX2 (277V). 2-wire system.33-lamp systems are wired for in-board, out-board operation.4Fuse kits are field installed. For large projects, consult factory for information on factory installation.5Use with emergency “E” option trims only. 6In emergency mode only one lamp will operate.7Initial lumens shown.

425lumens

600lumens

750lumens

RemoteOption

10" Standard Horizontal Fixture (frame: CM10)

11 1/8"(283 mm)

10 1/16"(256 mm)

9 13/16"(249 mm)

7/8"(22 mm)

8 3/8"(213mm)

15 1/32"(389mm)

11 3/8"(289mm)

16 1/2"(419 mm)

17 3/4"(451 mm)

CFLC O M P A C T F L U O R E S C E N T 1 0 "

H O R I Z O N T A L 3 - L A M P

H1053LLow Iridescent Clear Reflector H1053LELow Iridescent, EmergencyH1053LSLLow Iridescent, Self-Flanged*

H1033LGold Reflector H1033LEGold, Emergency

H1063LWhite Reflector H1063LEWhite, Emergency

H1073LWheat Reflector H1073LEWheat, Emergency

HWD1033LGold Reflector,Double Wall Wash

HW1033LGold Reflector,Single Wall Wash

HW1053LLow Iridescent Clear Reflector,Single Wall Wash

HWD1053LLow Iridescent Clear Reflector,Double Wall Wash

Black Baffle, Glass Lens InsertH105BC3LClear LensH105BF3LFresnel LensH105BP3LC73 Prismatic Lens

Clear Cone, Glass Lens InsertH105C3LClear LensH105F3LFresnel LensH105P3LC73 Prismatic Lens

White Splay, Glass Lens InsertH106C3LClear LensH106F3LFresnel LensH106P3LC73 Prismatic Lens

White Baffle, Glass Lens InsertH105WBC3LClear LensH105WBF3LFresnel LensH105WBP3LC73 Prismatic Lens

H105WB3LLow Iridescent Reflector,White Baffle H105WB3LELow Iridescent, White Baffle,Emergency

H105B3LLow Iridescent Reflector,Black Baffle H105B3LELow Iridescent, Black Baffle,Emergency

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM10-F326S3ER-HW1033L-CH241

Reflectors

ww

w.caprilighting.com

39

10

INC I N C A N D E S C E N T 1 0 "

V E R T I C A L

Frame

Electrical

40

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

Maximum Wattage

CatalogNumber Incandescent Lamp Type Typical Reflectors V104 Black Reflector Lensed Reflectors

A300 A 200W 200W 200W

PS25 300W 200W 200W

PAR38 250W 150W 100W

R/BR40 300W 150W 100W

CM10Metal frame with 10"aperture.

CM10RRemodel metal frame for10"aperture applications.

CM10SSlope ceiling metal frame for 10"aperture applications.For use with slope ceiling trims only.

Requires ceiling cutout of 16". For use in 24" on center joist construction only.

For use in 2" x 4" ceiling tile systems only.

11 1/8"(283 mm)

10 1/16"(256 mm)

9 7/8"(251 mm)

7/8"(22 mm)

16 1/16"(408 mm)

16 1/2"(419 mm)

15 1/32"(389mm)

11 3/8"(289mm)

7 1/16"(229 mm) 2 1/2"

(64 mm)

6 15/16"(164 mm)

10 27/32"(275 mm)

14 1/32"(356 mm)

7 1/4"(184 mm)

10 7/16"(265 mm)

10" Remodel MetalFrame (frame: CM10R)

10" Standard IncandescentFixture (frame: CM10)

10

16 13/32"(417 mm)

21 9/16"(548 mm)

19"(483 mm)

4 3/4"(121 mm)

10" Slope Ceiling Metal Frame (frame: CM10S)

Max Height: 21-11/16"(see spec sheet for

complete height data)

INCReflectors

I N C A N D E S C E N T 1 0 "

V E R T I C A L

Denotes c/UL wet location listing. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM10S-A300-V105SR30-CH241

ww

w.caprilighting.com

41

Slope ReflectorsClear Reflector, White Dome (for all slope trims) For use with CM10S Slope Housing only Ceiling cutout: 16" diameter

V105SR10 V105SR20 V105SR30Accommodates 5˚-15˚ Slope Accommodates 16˚-25˚ Slope Accommodates 26˚-35˚ SlopeV105SR40Accommodates 36˚-45˚ Slope

V104Black ReflectorV104SLBlack, Self-Flanged*

V103Gold ReflectorV103SLGold, Self-Flanged*

V105Low Iridescent Clear Reflector V105SLLow Iridescent, Self-Flanged*

V106White ReflectorV106SLWhite, Self-Flanged*

V105BLow Iridescent Reflector, Black Baffle

V107Wheat ReflectorV107SLWheat, Self-Flanged*

V105WBLow Iridescent Reflector, White Baffle

VWD103Gold Reflector,Double Wall Wash

VW103Gold Reflector,Single Wall Wash

VW105Low Iridescent Clear Reflector,Single Wall Wash

VWD105Low Iridescent Clear Reflector,Double Wall Wash

White Splay, Glass Lens InsertV106CClear LensV106FFresnel LensV106PC73 Prismatic Lens

Clear Cone, Glass Lens InsertV105CClear LensV105FFresnel LensV105PC73 Prismatic Lens

Black Baffle, Glass Lens InsertV105BCClear LensV105BFFresnel LensV105BPC73 Prismatic Lens

White Baffle, Glass Lens InsertV105WBCClear LensV105WBFFresnel LensV105WBPC73 Prismatic Lens

10

Electronic BallastMagnetic Ballast Options Fuse(standard)1

120/277V 120/347V Options3 EmergencyCatalog Lamp 120/277V Consult Factory See Chart

RestrikeNumber Designation EBU for availability C2

Page 45 E4,5,9

ELECTRONIC / MAGNETIC COMPATIBLE

M1006 CMH100/PAR 38, CMH100/ED-17P/C/MED, � Available � � �MP100/ED-17/C/MED (ANSI M90, M140)

ML1007 CMH100/PAR 38, CMH100/ED-17/C/MED, � Available � � �M100/ED-17/C/MED (ANSI M90, M140)

M1506 CMH150/PAR 38, CMH150/ED-17P/C/MED, � Canada Only � � �MP150/ED-17/C/MED (ANSI M102, M142)

ML1507 CMH150/PAR 38, CMH150/ED-17/C/MED, � Canada Only � � �M150/ED-17/C/MED (ANSI M102, M142)

MAGNETIC ONLY

M1756,8 MP175/C/U/MOG (ANSI M57/O) Canada Only � � �

ML1757,8 M175/C/U/MOG (ANSI M57/E) Canada Only � � �

M2506,8 MP250/C/U/MOG (ANSI M58/O) Canada Only � � �

ML2507,8 M250/C/U/MOG (ANSI M58/E) Canada Only � � �

1Effective January 1, 2009, Electronic ballasts are standard to conform to EISA. Consult factory for magnetic availability.2347V available only on magnetic ballasts.3HID Fuse kits vary depending on wattage and voltage. Refer to chart on page 45 to determine the correct fuse kit for your application.4Use T4 quartz bayonet base lamps.5Use with emergency "E" option trims only.6Use open rated lamps only.7For use with lensed trims only. 8Not available in the U.S. market.9Not available for sloped ceiling systems.

11 1/8"(283 mm)

10 1/16"(256 mm)

9 7/8"(251 mm)

7/8"(22 mm)

16 1/16"(408 mm)

15 1/32"(389mm)

11 3/8"(289mm)

16 1/2"(419 mm)

17 3/8"(441 mm)

11 1/8"(283 mm)

10 1/16"(256 mm)

9 7/8"(251 mm)

7/8"(22 mm)

16 1/16"(408 mm)

15 1/32"(389mm)

11 3/8"(289mm)

16 1/2"(419 mm)

17 3/8"(441 mm)

HID M E T A L H A L I D E 1 0 "

V E R T I C A L

CM10Metal frame with 10"aperture.

Frame

Electrical

42

ww

w.c

apri

light

ing.

com

NOTE: Bar hangers not included.See page 45 for ordering information.

CM10SSlope ceiling metal frame for 10"aperture applications.For use with slope ceiling trims only.

Not for use with integral emergency options.

Requires ceiling cutout of 16". For use in 24" on center joist construction only.

For use in 2" x 4" ceiling tile systems only.

10" Standard HID Fixture (frame: CM10) 10" Standard HID

Fixture with Emergency Option (frame: CM10)

10

16 13/32"(417 mm)

21 9/16"(548 mm)

19"(483 mm)

4 3/4"(121 mm)

10" Slope Ceiling Metal Frame (frame: CM10S)

Max Height: 21-11/16" (see spec sheet for completeheight data)

V104Black Reflector V104EBlack, EmergencyV104SLBlack, Self-Flanged*

V103Gold ReflectorV103EGold, EmergencyV103SLGold, Self-Flanged*

V105Low Iridescent Clear Reflector V105ELow Iridescent, Emergency V105SLLow Iridescent, Self-Flanged*

V106White ReflectorV106EWhite, EmergencyV106SLWhite, Self-Flanged*

V105BLow Iridescent Reflector,Black Baffle V105BELow Iridescent, Black Baffle,Emergency

V107Wheat ReflectorV107EWheat, EmergencyV107SLWheat, Self-Flanged*

V105WBLow Iridescent Reflector, White BaffleV105WBELow Iridescent, White Baffle,Emergency

Denotes c/UL wet location listing. Emergency trims are dry location listed only. 1 See page 45 for bar hanger options.* Self-Flanged have same finish as reflector.

Sample C1 catalog number: CM10-ML100EBU-V106C-CH241

HIDReflectors

M E T A L H A L I D E 1 0 "

V E R T I C A Lw

ww

.caprilighting.com

43

VW103Gold Reflector,Single Wall Wash

VWD103Gold Reflector,Double Wall Wash

VWD105Low Iridescent Clear Reflector,Double Wall Wash

VW105Low Iridescent Clear Reflector,Single Wall Wash

Black Baffle, Glass Lens InsertV105BCClear LensV105BFFresnel LensV105BPC73 Prismatic Lens

Clear Cone, Glass Lens InsertV105CClear LensV105FFresnel LensV105PC73 Prismatic Lens

White Splay, Glass Lens InsertV106CClear LensV106FFresnel LensV106PC73 Prismatic Lens

White Baffle, Glass Lens InsertV105WBCClear LensV105WBFFresnel LensV105WBPC73 Prismatic Lens

Slope ReflectorsClear Reflector, White Dome (for all slope trims) For use with CM10S Slope Housing only Ceiling cutout: 16" diameter

V105SR10 V105SR20 V105SR30Accommodates 5˚-15˚ Slope Accommodates 16˚-25˚ Slope Accommodates 26˚-35˚ SlopeV105SR40Accommodates 36˚-45˚ Slope

10

44

ww

w.c

apri

light

ing.

com

HID Emergency Restrike OptionRestrike option senses circuit power interruptions. If power is lost, the unit will switch on a 100 wattmaximum T4 bayonet base quartz lamp (sold separately) immediately after power is restored. The quartz lamp will stay lit until the HID lamp restrikes and comes up to 50% brightness. Consult pages of individual HID electrical systems for availability.

Restrike option is designated as E.Example: M50E.

Compact Fluorescent Emergency OptionsEmergency options sense circuit power interruptions.If power is lost, the rechargeable battery unit willswitch one compact fluorescent lamp on immediately.The lamp will remain lit for a minimum of 90 minutes,or until power is restored. Test switch and indicatorlight can be integral (as shown) or mounted remotely.

Integral emergency options are designated as E.Example: F226/32/42UE. Integral units must be usedwith an emergency reflector.

Remote emergency options are designated as ER.Example: F226/32/42UER.

Metal Frame Insert RingsThe CM4, CM6 and CM8 metal frames have interchangeable insert rings. Insert rings can be ordered separately for easy conversion in the field.

OVC162" Oversize trim ring for 6" reflectors

OVC182" Oversize trim ring for 8" reflectors

OVC1102" Oversize trim ring for 10" reflectors

CMR44" Ring

CMR66" Ring

CMR88" Ring

Insert Rings

Oversize Trim Ring Emergency Options

Accessories

ww

w.caprilighting.com

45

BH3 27" Flat Bar HangersIncludes holes for nailing to joists on 16" to 24" centers. May be used vertically or horizontally by placing through pre-formed slots in the butterfly brackets on all Capri One frames.

BH1 Adjustable Bar HangersThe BH1 slides vertically into the C1 frame butterflybrackets and is easily field-adjustable up to 25-1/2". They are pre-nailed and can be mounted on wooden joists or commercial t-grid ceilings.

CH24 C-Channel Bar Hangers

26" long, notched to fit vertical runner of mechanicalT-grid ceilings spaced 24" on center. Ends can befolded over to lock onto T-grid.

CH48 C-Channel Bar Hangers

Also available in 50" long, notched to fit vertical runners spaced 48" on center.

Bar Hangers Fuse Kits

Factory InstallationFactory Installed FusesFFor large projects, consult factory for informationon factory-installed fuses. All factory-installedfuses are designated F. Specific fuse designations (i.e. FS2, FS4, etc.) are not required.

Compact Fluorescent Fuse KitsFS2All compact fluorescent units use the FS2 fuse assembly. If ordering a fuse kit in conjunction with a C1 fixture, add it to your catalog numberbetween the electrical system and emergency options. Example: CM4-FV13UFS2ER-V44.

HID Fuse KitsFS2, FS4, FS6, FS8See chart below to determine the correct fuse kit for your application. You must know the voltage before ordering a fuse kit. If ordering a fuse kit in conjunction with a C1 fixture, add it to your catalog numberbetween the electrical system and emergency options. Example: CM8-H150CFS4E-V87E.

C1 Fuse Components C1 Fuse Installation Kit

Electronic Ballasts Magnetic Ballasts

Wattage Lamp Type 120-277V 120V 277V 347V

20 Metal Halide FS2 N/A N/A N/A

35 Metal Halide FS2 FS4 FS2 N/A

50 Metal Halide FS2 FS4 FS2 N/A

70 Metal Halide FS2 FS4 FS2 FS2

100 Metal Halide FS2 FS6 FS4 FS4

150 Metal Halide FS2 FS8 FS4 N/A

175 Metal Halide N/A FS8 FS3 FS3

250 Metal Halide N/A FS8 FS3 FS3

V E R T I C A L H O R I Z O N T A L

1-Lamp 2-Lamp 3-LampWattages 4" 6" 8" 10" 6" 8" 10" 6" 8" 10" 10"

13 FV13 FV13 FV13 F113 F113 F213 F213

18 FV18 FV18 FV18 F118 F118 F218 F218

26/32/42 FV26/32/42 FV26/32/42 FV26/32/42 FV26/32/42 F126/32/42 F126/32/42 F126/32/42 F226/32/42 F226/32/42 F226/32/42 F326/32/42

26 FV26 FV26 FV26 FV26 F126 F126 F126 F226 F226 F226 F326

32 FV32 FV32 FV32 FV32 F132 F132 F132 F232 F232 F332

42 FV42 FV42 FV42 FV42 F142 F142 F142 F242 F242 F342

Page No. 8 12 22 32 14 24 34 16 26 36 38

46

ww

w.c

apri

light

ing.

com

Product Availability

M A X I M U M L A M P W A T T A G E S

A300Lamp Type 4" 6" 8" 10"

A 60W 150W 200W 200W

PAR 16 60W

PAR 20 50W

PAR 30 75W 75W

PS25 300W

R/BR30 75W 100W

PAR 38 150W 250W 250W

R/BR40 150W 300W 300W

Page No. 9 18 28 40

CFL

E L E C T R O N I C B A L L A S T 1

Magnetic BallastOpen Lensed Availability1

Wattages 4" 6" 8" 10" 4" 6" 8" 10" Consult Factory

20 M20 M20 M20 ML20 ML20 ML20 N/A

39 M35 M35 M35 ML35 ML35 ML35 Available

50 M50 M50 M50 ML50 ML50 ML50 Available

70 M70 M70 M70 ML70 ML70 ML70 Available

100 M100 M100 M100 ML100 ML100 ML100 Available

150 M150 M150 ML150 ML150 Canada Only

175 Electronic ballasts are not available for 175 watt metal halide systems Canada Only

250 Electronic ballasts are not available for 250 watt metal halide systems Canada Only

Page No. 10 20 30 42 10 20 30 42

1Effective January 1, 2009, Electronic ballasts are standard to conform to EISA. Consult factory for magnetic availability.

HID

INC

Capri One Number Lamp Initial Lumens InputElectrical System of Lamps Designation per Lamp Watts

FV13 1 CFQ13W/G24q 900 16

F113 1 CFQ13W/G24q 900 16

F213 2 CFQ13W/G24q 900 29

FV18 1 CFQ18W/G24q, CFM18W/GX24q 1250 18

F118 1 CFQ18W/G24q, CFM18W/GX24q 1250 18

F218 2 CFQ18W/G24q, CFM18W/GX24q 1250 36

FV26/32/42 1 CFQ26W/G24q 1800 29CFM26W/GX24q 1800 29CFM32W/GX24q 2400 36CFM42W/GX24q 3200 48

F126/32/42 1 CFQ26W/G24q 1800 29CFM26W/GX24q 1800 29CFM32W/GX24q 2400 36CFM42W/GX24q 3200 48

F226/32/42 2 CFQ26W/G24q 1800 54CFM26W/GX24q 1800 54CFM32W/GX24q 2400 72CFM42W/GX24q 3200 93

F326/32/42 3 CFQ26W/G24q 1800 81CFM26W/GX24q 1800 81CFM32W/GX24q 2400 108CFM42W/GX24q 3200 141

FV26 1 CFQ26W/G24q, CFM26W/GX24q 1800 29

F126 1 CFQ26W/G24q, CFM26W/GX24q 1800 29

F226 2 CFQ26W/G24q, CFM26W/GX24q 1800 54

F326 3 CFQ26W/G24q, CFM26W/GX24q 1800 81

FV32 1 CFM32W/GX24q 2400 36

F132 1 CFM32W/GX24q 2400 36

F232 2 CFM32W/GX24q 2400 72

F332 3 CFM32W/GX24q 2400 108

FV42 1 CFM42W/GX24q 3200 48

F142 1 CFM42W/GX24q 3200 48

F242 2 CFM42W/GX24q 3200 93

F342 3 CFM42W/GX24q 3200 141

FV57 1 CFM57W/GX24q 4300 65

ww

w.caprilighting.com

47

CFL Lamp Data

48

ww

w.c

apri

light

ing.

com

INC Lamp Data

Capri One Number Lamp Initial LumensElectrical System of Lamps Designation per Lamp

A300 1 50A19 790

1 100A19 1650

1 150A21 2850

1 200A23 3800

1 60PAR16 580

1 50PAR20 550

1 75PAR30/H/SP 6700 CP

1 75PAR30/H/FL 2200 CP

1 75BR30/SP 1625 CP

1 75BR30/FL 525 CP

1 100PAR38/H/SP 17000 CP

1 100PAR38/H/FL 4800 CP

1 150PAR38/H/SP 23000 CP

1 150PAR38/H/FL 6500 CP

1 250PAR38/H/SP 40000 CP

1 250PAR38/H/FL 8000 CP

1 120BR40/SP 4600 CP

1 120BR40/FL 1000 CP

1 150BR40/SP 6700 CP

1 150BR40/FL 1450 CP

1 300BR40 N/A

1 300PS25 6300

1 300PS35 5700

ww

w.caprilighting.com

49

Capri One Number Lamp Initial Lumens InputElectrical System of Lamps Designation per Lamp Watts1, 2

M203 1 CMH20/PAR30/SP 1,200 231 CMH20/PAR30/FL 1,200 231 CMH20 PAR20/SP 1,000 231 CMH20 PAR20/FL 1,000 23

ML20 1 CMH20/PAR30/SP 1,200 231 CMH20/PAR30/FL 1,200 231 CMH20 PAR20/SP 1,000 231 CMH20 PAR20/FL 1,000 23

M353 1 CMH35/PAR30/SP 2,200 441 CMH35/PAR30/FL 2,200 441 CMH35/PAR20/SP 2,000 441 CMH35/PAR20/FL 2,000 44

ML35 1 CMH35/PAR30/SP 2,200 441 CMH35/PAR30/FL 2,200 441 CMH35/PAR20/SP 2,000 441 CMH35/PAR20/FL 2,000 44

M503 1 CMH50/ED-17P/MED 4,000 581 MP50/ED-17/MED 3,200 58

ML50 1 CMH50/ED-17/MED 4,100 581 M50/ED-17/MED 3,000 58

M703 1 CMH70/PAR 38/SP 4,100 781 CMH70/PAR 38/FL 4,100 781 CMH70/PAR 30/SP 5,000 781 CMH70/PAR 30/FL 5,000 781 CMH70/ED-17P/MED 5,400 781 MP70/ED-17/MED 5,400 78

ML70 1 CMH70/PAR 38/SP 4,100 781 CMH70/PAR 38/FL 4,100 781 CMH70/PAR 30/SP 5,000 781 CMH70/PAR 30/FL 5,000 781 CMH70/ED-17/MED 5,800 781 M70/ED-17/MED 5,300 78

M1003 1 CMH100/PAR 38/SP 6,200 1101 CMH100/PAR 38/FL 6,200 1101 CMH100/ED-17P/MED 7,900 1101 MP100/ED-17/MED 8,500 110

ML100 1 CMH100/PAR 38/SP 6,200 1101 CMH100/PAR 38/FL 6,200 1101 CMH100/ED-17/MED 8,800 1101 M100/ED-17/MED 8,500 110

M1503 1 CMH150/PAR 38/SP 9,100 1671 CMH150/PAR 38/FL 9,100 1671 CMH150/ED-17P/MED 11,900 1671 MP150/ED-17/MED 12,000 167

ML150 1 CMH150/PAR 38/SP 9,100 1671 CMH150/PAR 38/FL 9,100 1671 CMH150/ED-17/MED 12,500 1671 M150/ED-17/MED 12,600 167

M1753, 4 1 MP175/C/U/MOG 15,000 205

ML1754 1 M175/C/U/MOG 16,000 205

M2503, 4 1 MP250/C/U/MOG 22,000 290

ML2504 1 M250/C/U/MOG 23,750 290

1 Effective January 1, 2009, Electronic ballasts are standard to conform to EISA. Consult factory for magnetic availability.2 Input wattage may vary by ballast manufacturer.3 Use open rated lamps only.4 Available in magnetic ballast for the Canadian market only.

HID Lamp Data

Capri Lighting is a Philips Group brand

776 South Green StreetTupelo, Mississippi 38802Phone (662) 841-5501Fax (662) 680-6619www.caprilighting.com

189 Bullock DriveMarkham, Ontario, L3P 1W4Phone (905) 294-9570Fax (905) 294-9811www.thomaslightingcanada.com

©2008 Philips Group.All rights reserved. Certain products illustrated in this catalog may be protected by applicable patents and patents pending. Capri Lighting will aggressively defend all of its intellectual property. We reserve the right to change details of design, materials and finishes.

Brochure C19.08.CT7.5M

Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain

small amounts of mercury. Such lamps are labeled “Contains Mercury” and/or with the symbol “Hg.” Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycling and disposal can be found at www.lamprecycle.org.

Printed in the U.S.A.