The Safe Transfer of Pressurized Gas
description
Transcript of The Safe Transfer of Pressurized Gas
![Page 1: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/1.jpg)
The Safe Transferof
Pressurized Gas
![Page 2: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/2.jpg)
Collect the Necessary Tools and Equipment
• Safety Glasses for EVERYONE• SCUBA Tank filled to 3000 psi• Fill Station • Storage Tank and Regulator • Adjustable Strapping
![Page 3: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/3.jpg)
![Page 4: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/4.jpg)
SCUBA Tanks
Portable
Readily Available
Inexpensive
Lightweight
•SCUBA Certification
•Limited Capacity
![Page 5: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/5.jpg)
Fill StationsThis is a commercially available fill station manufactured for paintball enthusiasts.
![Page 6: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/6.jpg)
Fill StationsThis is a custom built fill station fabricated by a local welding supply company from off the shelf parts.
Note: All parts rated at 3000 psi
![Page 7: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/7.jpg)
Tank and RegulatorThis is a 47ci Aluminum paintball tank with an Air America Tobor™ regulator that has been modified to conform to the BBIQ Technical Rules and Regulations
![Page 8: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/8.jpg)
Before Every Fill…
• Put on Safety Glasses• Check the Valve and O-ring on the SCUBA Tank.
Replace defective O-Rings. Do not use a tank with a damaged valve surface.
![Page 9: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/9.jpg)
Be SafeInspect the Equipment Every TimeAll the Time
![Page 10: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/10.jpg)
Prevent Serious Accidents
Always Secure High Pressure Storage Bottles to Rigid Structures
A Busted Valve Will Turn This Tank Into a Rocket Capable of Piercing the Wall of a Building.
![Page 11: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/11.jpg)
![Page 12: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/12.jpg)
Attach the HPA Storage Tank to the Fill Station
Check the HPA Storage Tank Fittings for Visible Damage
Be Certain the HPA Storage Tank Valve is Closed
![Page 13: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/13.jpg)
Respect the Quick Connect
Make certain the connection is secure and the male and female ends have engaged.
Test the connection by tugging on the tank
![Page 14: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/14.jpg)
![Page 15: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/15.jpg)
Ready To FillCheck the Setup
Check the Gages
Check the Connections
![Page 16: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/16.jpg)
Fill the Tank S-L-O-W
Slowly Open the Valve on the SCUBA TankWatch the GagesFeel the Tank TemperatureTake Your Time
![Page 17: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/17.jpg)
CAUTIONFollow This Procedure to Remove
the Tank
1.) Close the SCUBA Tank Valve
Note: The Fill Station and Tank connection will remain pressurized
2.) Open the Fill Station Bleed Valve
Note: The Tank does not empty because the male Quick Connect fitting is a one way check valve.
![Page 18: The Safe Transfer of Pressurized Gas](https://reader036.fdocuments.us/reader036/viewer/2022081514/568150f3550346895dbf108f/html5/thumbnails/18.jpg)
CongratulationsYou now have approximately 10 Watt Hours of energy available.
Be a great engineer.
Use it wisely.
Low PressureApprox. 1Mpa High
Pressure2200 psi