The QUINTON Quik-Prep Automated Patient Prep Systemjrtassociates.com/pdfs/quik_prep.pdf · Holter...

2
Primary Users Physicians, nurses, and medical technicians Primary Benefits Quality. Automatically prep to optimal impedance for consistently superior diagnostic results. Comfort. Patients appreciate the speed and ease of application. Convenience. You can use a Quik-Prep radiotranslucent single electrode for all ECG-based exams. Efficiency. The Quik-Prep system’s speed and accuracy provide a cost-effective electrode solution. The quick, convenient prep system that ensures a quality trace The QUINTON ® Quik-Prep Automated Patient Prep System Compare the trace quality Two traces taken simultaneously during exercise with treadmill at 5.0 mph, 3.5% grade, and HR at 148 BPM. Automated Quik-Prep System Manual prep using a popular foam electrode Cardiac Science co-developed diagnostic cardiac testing over the past 40 years. We understand the demands that stress testing and Holter monitoring place on trace quality. Our Quik-Prep System was designed to meet these demands. e world’s only automated prepping system e Quinton Quik-Prep system puts an end to manually prepping patients by automating the process. e automated applicator eliminates unpredictability, reduces the time required for a prep, and ensures optimal trace quality. e Quik-Prep electrodes are specifically designed to hold up, and hold on, during heavy perspiration, excessive patient movement, and leadwire tugging. Here’s how Quik-Prep works e Quik-Prep system consists of disposable, self-prepping electrodes and an electronic applicator system. e technician centers the applicator over the electrode and by pressing the button, spins the center of the electrode, prepping the skin. When the applicator’s micro-electronic circuitry measures optimal impedance, a ready light indicates the prep is complete. e entire process takes less than three seconds. Better results, lower cost Because each site is electronically prepped to optimal impedance, technicians prep patients faster and with confidence, knowing that each prep site will produce a quality trace virtually free of dropout and baseline drift. You won’t be wasting time or supplies repeating tests because of an improper prep or poor signal transmission. at makes using Quik-Prep electrodes less costly than most standard electrodes.

Transcript of The QUINTON Quik-Prep Automated Patient Prep Systemjrtassociates.com/pdfs/quik_prep.pdf · Holter...

Primary Users

Physicians, nurses, and medical technicians

Primary Benefits

Quality. Automatically prep to optimal impedance for consistently superior diagnostic results.

Comfort. Patients appreciate the speed and ease of application.

Convenience. You can use a Quik-Prep radiotranslucent single electrode for all ECG-based exams.

Efficiency. The Quik-Prep system’s speed and accuracy provide a cost-effective electrode solution.

The quick, convenient prep system that ensures a quality trace

The QUINTON® Quik-Prep™ Automated Patient Prep System

Compare the trace quality

Two traces taken simultaneously during exercise with treadmill at 5.0 mph, 3.5% grade, and HR at 148 BPM.

Automated Quik-Prep System

Manual prep using a popular foam electrode

Cardiac Science co-developed diagnostic cardiac testing over the past 40 years. We understand the demands that stress testing and Holter monitoring place on trace quality. Our Quik-Prep System was designed to meet these demands.

The world’s only automated prepping system

The Quinton Quik-Prep system puts an end to manually prepping patients by automating the process. The automated applicator eliminates unpredictability, reduces the time required for a prep, and ensures optimal trace quality. The Quik-Prep electrodes are specifically designed to hold up, and hold on, during heavy perspiration, excessive patient movement, and leadwire tugging.

Here’s how Quik-Prep works

The Quik-Prep system consists of disposable, self-prepping electrodes and an electronic applicator system. The technician centers the applicator over the electrode and by pressing the button, spins the center of the electrode, prepping the skin. When the applicator’s micro-electronic circuitry measures optimal impedance, a ready light indicates the prep is complete. The entire process takes less than three seconds.

Better results, lower cost

Because each site is electronically prepped to optimal impedance, technicians prep patients faster and with confidence, knowing that each prep site will produce a quality trace virtually free of dropout and baseline drift. You won’t be wasting time or supplies repeating tests because of an improper prep or poor signal transmission. That makes using Quik-Prep electrodes less costly than most standard electrodes.

Green light illuminates when prep is complete

Battery operated and rechargeable

Tab secures leadwire to prevent movement

Electrodes are radiotranslucent and contain no latex rubber or PVC material

Locking collar stabilizes electrode, reducing motion artifact

Rotating center automatically provides a fast and e�ective prep

Applicator electronically measures impedance for optimum trace quality

Cardiac Science Corporation • 3303 Monte Villa Parkway, Bothell, WA 98021 USA • 425.402.2000 • US toll-free 800.426.0337 • Fax: 425.402.2001 • [email protected] and Customer Care (US and International) • 425.402.2000 • US toll-free 800.426.0337 • Fax: 425.402.2001 • [email protected] Technical Support • (US) Fax: 425.402.2022 • [email protected] • http://websupport.cardiacscience.com/webchat/ • (International) [email protected] Science International A/S • Kirke Vaerloesevej 14, DK-3500 Vaerloese, Denmark • +45.4438.0500 • Fax: +45.4438.0501 • [email protected] Kingdom • The Manse, 39 Northenden Road, Sale, Manchester, M33 2DH, United Kingdom • +44.161.926.0000 • [email protected] France • Parc de la Duranne, 565, Rue René Descartes, F-13857 Aix-en-Provence Cedex 3, France • +33.4.88.19.92.92 • [email protected] Europe (D, A, CH) • Oskar-Schindler-Strasse 3, D-50769 Köln, Germany • +49.221.33734.300 • [email protected] China • 6/F South Building, 829, Yi Shan Road, Shanghai 200233, China • +86.21.6495.9121 • [email protected]

Cardiac Science, the Shielded Heart logo, Burdick, Quinton, HeartCentrix, Atria, Assurance, Heartline, and CardioSens are trademarksof Cardiac Science Corporation. Copyright © 2008 Cardiac Science Corporation. All Rights Reserved. MKT-13101-01rAAuthorized EU representative • MDSS GmbH, Schiffgraben 41, D-30175 Hannover, Germany

The QUINTON® Quik-Prep™ Automated Patient Prep System

Compare the Quik-Prep System with Your Prep Method Quik-Prep System

Your Electrode

Manual patient preps are not required YesElectronically-measured impedance at each electrode site for consistent, superior diagnostic results

Yes

Abrasive and conductive gels not required YesLocking collar to minimize patient-induced motion artifact and noise YesHypoallergenic adhesive to ensure that electrodes stay on diaphoretic patients

Yes

Dual purpose tab to facilitate handling and secure lead wires YesIdeal for all ECG based examinations YesFree of latex rubber and PVC material YesCost effective single electrode solution Yes

“We experimented with several different products from other companies before finally settling on the Quinton product. Unequivocally, Quik-Prep out performed all of the other products – hands down!”“…they consistently give us excellent tracings.”“…we anticipate utilizing this product long into the future.”

Gary Williams, MSN, RN Program Manager Non-Invasive Cardiovascular Services University of Texas Medical Branch at Galveston

“We have been using Quinton Quik-Prep electrodes and the Quik-Prep system since our first office opened in 1990. We have found the Quik-Prep electrodes to provide ease of patient prepping as well as reliable and accurate tracings. Our cardiologists and nurses all have the utmost confidence in the Quinton Quik-Prep system.”

Gene Hecht, VP Nuclear Medicine Doshi Diagnostic Imaging Services, P.C.

Janet
Text Box
Janet
Text Box
This product is available through: JRT Associates 800-221-0111