The premium performance The unique MULTISEP design provides · The premium performance The unique...
Transcript of The premium performance The unique MULTISEP design provides · The premium performance The unique...
The premium performanceThe unique MULTISEP design provides steady high flow rates of oxygen with minimum footprint requirement. Together with molecular sieve protection from moisture substantially lower the service costs, extends the lifetime and provides savings.
Standard FeaturesColored touch screen controlBuilt in purity analyzer for constant monitoringModbus TCP, Ethernet connectionRemote start/stop relayData-logging via USB interface
Optional add-onsFlow control valve – flow & purity adjustmentEnergy saving valve – reduces compressed air usage during turn downPurity control – off spec purgeSequential start/stop – one button operationSMS alarmRemote monitoringAudio-visual alarmand other
KEY BenefitsZeolite anti-crush designNo channeling effectMinimized footprintMolecular sieve protectionSiemens based control systemStainless steel pipingDesigned for dynamic pressure loading
Typical applicationsCutting/WeldingFish farmingGlass productionGold leachingHealth-careOzone productionVeterinaryWater treatment
Model
O80T O100TO125TO150TO3080O3100O3125O3150O4080O4100O4125O4150O5080O5100O5125O5150
Oxygen capacity
m3/h92,2
114,3140,8173,9138,3171,5211,2260,8184,4228,6281,6347,7230,5285,8352,0434,7
kg/h122,6152,0187,3231,2183,9228,1280,9346,9245,2304,1374,5462,5306,6380,2468,1578,1
kg/h114,6142,1175,0216,1171,9213,2262,5324,2229,2284,2350,0432,2286,5355,3437,5540,3
m3/h86,2
106,8131,6162,5129,2160,3197,4243,8172,3213,7263,2325,0215,4267,1328,9406,2
kg/h103,1127,9157,5194,5154,7191,9236,3291,8206,3255,8315,0389,0257,9319,8393,8486,3
m3/h77,596,2
118,4146,2116,3144,3177,6219,4155,1192,3236,8292,5193,9240,4296,1365,6
Notes
Performance data is based on 7 barG inlet pressure and 20°C to 30°C ambient temperature.
Flow stated in cubic meter (m3) is with reference conditions, Temperature: 20°C, Pressure: 1.013 barA.
Conversion factor for m3 with reference conditions, Temperature: 0°C, Pressure: 1.013 barA is 0.69 m3/kg.
Designs and specifications are subject to change without notice or obligation.
Operating conditionsAmbient temperature rangeOxygen outlet pressure Oxygen dew point Air inlet pressure Inlet air quality Pressure dew pointFiltration gradePower supply
5°C to 50°C4 to 6 barG-50°C ( -70°C)7.5 to 10 barGISO: 8573.1:2010 class 1.4.1.3°C0.01 micron110-240V / 50-60Hz
90% 93% 95%