The premium performance The unique MULTISEP design provides · The premium performance The unique...

2
The premium performance The unique MULTISEP design provides steady high flow rates of oxygen with minimum footprint requirement. Together with molecular sieve protection from moisture substantially lower the service costs, extends the lifetime and provides savings. Standard Features Colored touch screen control Built in purity analyzer for constant monitoring Modbus TCP, Ethernet connection Remote start/stop relay Data-logging via USB interface Optional add-ons Flow control valve – flow & purity adjustment Energy saving valve – reduces compressed air usage during turn down Purity control – off spec purge Sequential start/stop – one button operation SMS alarm Remote monitoring Audio-visual alarm and other www.oxywise.com [email protected]

Transcript of The premium performance The unique MULTISEP design provides · The premium performance The unique...

Page 1: The premium performance The unique MULTISEP design provides · The premium performance The unique MULTISEP design provides steady high flow rates of oxygen with ... Performance data

The premium performanceThe unique MULTISEP design provides steady high flow rates of oxygen with minimum footprint requirement. Together with molecular sieve protection from moisture substantially lower the service costs, extends the lifetime and provides savings.

Standard FeaturesColored touch screen controlBuilt in purity analyzer for constant monitoringModbus TCP, Ethernet connectionRemote start/stop relayData-logging via USB interface

Optional add-onsFlow control valve – flow & purity adjustmentEnergy saving valve – reduces compressed air usage during turn downPurity control – off spec purgeSequential start/stop – one button operationSMS alarmRemote monitoringAudio-visual alarmand other

[email protected]

Page 2: The premium performance The unique MULTISEP design provides · The premium performance The unique MULTISEP design provides steady high flow rates of oxygen with ... Performance data

KEY BenefitsZeolite anti-crush designNo channeling effectMinimized footprintMolecular sieve protectionSiemens based control systemStainless steel pipingDesigned for dynamic pressure loading

[email protected]

Typical applicationsCutting/WeldingFish farmingGlass productionGold leachingHealth-careOzone productionVeterinaryWater treatment

Model

O80T O100TO125TO150TO3080O3100O3125O3150O4080O4100O4125O4150O5080O5100O5125O5150

Oxygen capacity

m3/h92,2

114,3140,8173,9138,3171,5211,2260,8184,4228,6281,6347,7230,5285,8352,0434,7

kg/h122,6152,0187,3231,2183,9228,1280,9346,9245,2304,1374,5462,5306,6380,2468,1578,1

kg/h114,6142,1175,0216,1171,9213,2262,5324,2229,2284,2350,0432,2286,5355,3437,5540,3

m3/h86,2

106,8131,6162,5129,2160,3197,4243,8172,3213,7263,2325,0215,4267,1328,9406,2

kg/h103,1127,9157,5194,5154,7191,9236,3291,8206,3255,8315,0389,0257,9319,8393,8486,3

m3/h77,596,2

118,4146,2116,3144,3177,6219,4155,1192,3236,8292,5193,9240,4296,1365,6

Notes

Performance data is based on 7 barG inlet pressure and 20°C to 30°C ambient temperature.

Flow stated in cubic meter (m3) is with reference conditions, Temperature: 20°C, Pressure: 1.013 barA.

Conversion factor for m3 with reference conditions, Temperature: 0°C, Pressure: 1.013 barA is 0.69 m3/kg.

Designs and specifications are subject to change without notice or obligation.

Operating conditionsAmbient temperature rangeOxygen outlet pressure Oxygen dew point Air inlet pressure Inlet air quality Pressure dew pointFiltration gradePower supply

5°C to 50°C4 to 6 barG-50°C ( -70°C)7.5 to 10 barGISO: 8573.1:2010 class 1.4.1.3°C0.01 micron110-240V / 50-60Hz

90% 93% 95%