THE ORIGINAL SOFT-FLOW ®* LOW-VELOCITY ARTERIAL … · 2019-12-04 · Soft-Flow®* cannulae are...

8
THE ORIGINAL SOFT-FLOW ® * LOW-VELOCITY ARTERIAL CANNULA The easy-to-insert, gentle-on-aorta cannulae

Transcript of THE ORIGINAL SOFT-FLOW ®* LOW-VELOCITY ARTERIAL … · 2019-12-04 · Soft-Flow®* cannulae are...

Page 1: THE ORIGINAL SOFT-FLOW ®* LOW-VELOCITY ARTERIAL … · 2019-12-04 · Soft-Flow®* cannulae are designed with your ease of use in mind and engineered to treat your patients gently.

THE ORIGINALSOFT-FLOW ®*

LOW-VELOCITYARTERIAL CANNULAThe easy-to-insert, gentle-on-aorta cannulae

Page 2: THE ORIGINAL SOFT-FLOW ®* LOW-VELOCITY ARTERIAL … · 2019-12-04 · Soft-Flow®* cannulae are designed with your ease of use in mind and engineered to treat your patients gently.

WE HEAR YOU. THAT'S WHY WE BROUGHT SOFT-FLOW®* CANNULAE BACK.Your feedback ensures we continue to offer solutions that have made our cannula portfolio the largest worldwide.

In fact, your feedback is why we collaborated with MC3 to bring back the arterial cannulae cardiac surgeons have used for more than 20 years: the Original Soft-Flow Cannulae. Medtronic obtained the exclusive global distribution rights to Soft-Flow from MC3, so you could again use these favored† cannulae in your practice.

Our collaboration with MC3 continues today. We're working together to bring you even more enabling technology options, along with a vision for what's next. We are committed to listening to you and putting your patients first.

A commitment to exploring better outcomes. A commitment to hearing you.

AS GENTLE AS ALWAYS THE ORIGINAL LOW-VELOCITY AORTIC CANNULAWe understand your patients need a gentle, low-velocity cannulation solution for the ascending aorta. The Soft-Flow®* closed tip has an inner cone that purposefully directs flow through side ports. This results in a diffuse, lower velocity flow.

Important Safety Information Care and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery procedures. For a listing of indications, contraindications, precautions, warnings, and potential adverse events, please refer to the Instructions for Use. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.

† MC3, Inc. data on file. Based on 2010-11 U.S. Procedure Case Load and Marketing Data.

" Lower exit force and flow velocity may decrease the incidence of atheroemboli and stroke.”1

Page 3: THE ORIGINAL SOFT-FLOW ®* LOW-VELOCITY ARTERIAL … · 2019-12-04 · Soft-Flow®* cannulae are designed with your ease of use in mind and engineered to treat your patients gently.

REDUCE JETTING EFFECT

Advanced flow visualization analysis demonstrates Soft-Flow arterial cannula provides a divided blood flow pattern which lessens the jetting effect observed with open-tip aortic cannulae.** The closed diffusion tip is designed to help reduce the risk of dislodging plaque from the aortic wall.2

COMPARE VELOCITY PERFORMANCE**

Soft-Flow®* arterial angled tip cannula showed a lower exit velocity than the Medtronic Select Series™ arterial angled open-tip cannula in an independent 3C-PIV bench test.**

** MC3, Inc. data on file. Testing was conducted in 3rd-party laboratory setting with aortic arch models and CPB circuit that utilized a Three-Component Particle Image Velocimetry (3C-PIV) technology to capture flow data. 3D velocity data is visualized in one 2D plane per image. The images capture the peak velocity for each cannula. Flow still occurs in unshaded vessel areas.

Medtronic Select Series Angled Open-Tip Cannula

3.53.22.92.62.321.71.41.10.80.5Velocity (m/s)

Open-tip Cannula,22 Fr

Soft-FlowCannula,21 Fr

Soft-Flow Angled Tip Cannula

Page 4: THE ORIGINAL SOFT-FLOW ®* LOW-VELOCITY ARTERIAL … · 2019-12-04 · Soft-Flow®* cannulae are designed with your ease of use in mind and engineered to treat your patients gently.

Soft-Flow®* Angled Tip Cannulae

21 Fr

18 Fr

24 FrPres

sure

Dro

p (m

m H

g)

0 1 2 3 4 5 6

Flow Rate (L/min)H2O @ 22°C

200

160

120

80

40

0

Pres

sure

Dro

p (m

m H

g)

200

160

120

80

40

00 1 2 3 4 5 6

Flow Rate (L/min)H2O @ 22°C

Soft-Flow®* Extended Cannulae

21 Fr

24 Fr

Soft-Flow®* Straight Tip Cannulae

21 Fr

24 FrPres

sure

Dro

p (m

m H

g)

200

160

120

80

40

00 1 2 3 4 5 6

Flow Rate (L/min)H2O @ 22°C

RIGHT FLOW WHEN YOU NEED ITSoft-Flow®* cannula flow charts are provided for your comparison. Each flow curve represents in vitro laboratory data obtained using water at room temperature. The actual pressure drops encountered in a clinical situation may vary from those shown, depending on the blood viscosity and temperature. All pressure drops are measured in mm Hg and flow rates in liters of water per minute.

Important Safety Information Care and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery procedures. For a listing of indications, contraindications, precautions, warnings, and potential adverse events, please refer to the Instructions for Use. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.

Page 5: THE ORIGINAL SOFT-FLOW ®* LOW-VELOCITY ARTERIAL … · 2019-12-04 · Soft-Flow®* cannulae are designed with your ease of use in mind and engineered to treat your patients gently.

RIGHT TIP DESIGN MEANS AN EASIER INSERTIONYou want an aortic cannula that is easy to insert and helps provide the ideal flow performance for each patient. That’s Soft-Flow.®* See why it’s been a favorite† cannula among surgeons, perfusionists, and training institutions for more than 20 years.

� The tapered and reverse-angled tip1 with smooth rimmed bevel enables an easy and gentle insertion

� Predictably maneuvers through small incisions and into aorta

� Patented inner cone design with internal flow deflection � Soft dispersion pattern of blood through four side ports

� Convenient repositionable suture ring

� Avoids kinks with flexibile wirewound cannula body � Extended body model spans anatomical distances and

offers flexibilty

Soft-Flow®* Extended Body Cannula is shown

† MC3, Inc. data on file. Based on 2010-11 U.S. Procedure Case Load and Marketing Data.

Page 6: THE ORIGINAL SOFT-FLOW ®* LOW-VELOCITY ARTERIAL … · 2019-12-04 · Soft-Flow®* cannulae are designed with your ease of use in mind and engineered to treat your patients gently.

DESIGNED WITH YOUR EASE IN MINDSoft-Flow®* cannulae are designed with your ease of use in mind and engineered to treat your patients gently. Each wirewound cannula body is kink-resistant to make your procedures go easier. Explore the unique features of extended, straight, and angled diffuse-tip models to help find your ideal Soft-Flow arterial and deliver just the right flow.

EXTENDED BODY The extended Soft-Flow®* body length can be positioned across various patient anatomies to reach a little farther. Clearly visible depth markings and a repositionable suture ring further assist proper placement to meet your needs.

STRAIGHT TIP AND ANGLED TIP

A smooth, tapered, reverse-angled tip is designed to facilitate an easy insertion and a gentle flow. An orientation line is included to help you position the Soft-Flow®* angled-tip cannulae. An integrated suture bulb or suture flange also support placement. Choose a 3/8 inch vented or non-vented connector depending on your preference.

Page 7: THE ORIGINAL SOFT-FLOW ®* LOW-VELOCITY ARTERIAL … · 2019-12-04 · Soft-Flow®* cannulae are designed with your ease of use in mind and engineered to treat your patients gently.

ORDERING INFORMATION

Soft-Flow®* Angled Tip 14 in (35 cm) overall lengthwith suture bulb

Vented 3/8 in (0.95 cm) connector

7072 18 Fr (6.0 mm)

5761 21 Fr (7.0 mm)

5762 24 Fr (8.0 mm)

Non-vented 3/8 in (0.95 cm) connector

7071 18 Fr (6.0 mm)

5767 21 Fr (7.0 mm)

5768 24 Fr (8.0 mm)

10 per carton

Soft-Flow®* Angled Tip 14 in (35 cm) overall lengthwith suture flange

Vented 3/8 in (0.95 cm) connector

7080 18 Fr (6.0 mm)

6394 21 Fr (7.0 mm)

6386 24 Fr (8.0 mm)

Non-vented 3/8 in (0.95 cm) connector

6392 21 Fr (7.0 mm)

6384 24 Fr (8.0 mm)

10 per carton

Soft-Flow®* Extended 14.5 in (37 cm) overall length with suture ring

Vented 3/8 in (0.95 cm) connector

4949 21 Fr (7.0 mm)

4951 24 Fr (8.0 mm)

Non-vented 3/8 in (0.95 cm) connector

4948 21 Fr (7.0 mm)

4950 24 Fr (8.0 mm)

10 per carton

Soft-Flow®* Straight Tip 14 in (35 cm) overall length with suture bulb

Vented 3/8 in (0.95 cm) connector

5798 21 Fr (7.0 mm)

5841 24 Fr (8.0 mm)

Non-vented 3/8 in (0.95 cm) connector

5842 21 Fr (7.0 mm)

5843 24 Fr (8.0 mm)

10 per carton

Important Safety Information Care and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery procedures. For a listing of indications, contraindications, precautions, warnings, and potential adverse events, please refer to the Instructions for Use. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.

Page 8: THE ORIGINAL SOFT-FLOW ®* LOW-VELOCITY ARTERIAL … · 2019-12-04 · Soft-Flow®* cannulae are designed with your ease of use in mind and engineered to treat your patients gently.

medtronic.com/softflow

©2018 Medtronic. All rights reserved. Medtronic, Medtronic logo and Further, Together are trademarks of Medtronic. ®*Third party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.

UC201806745 EN 05/2018

710 Medtronic Parkway Minneapolis, MN 55432-5604 USA Tel: (763) 514-4000 Fax: (763) 514-4879 Toll-free: (800) 328-2518

LifeLine CardioVascular Technical Support Tel: (877) 526-7890 Tel: (763) 526-7890 Fax: (763) 526-7888 [email protected]

For more information, contact your local Medtronic Cannula Products Representative. U.S. Customer Service: (800) 328-1357.

References 1 Muehrcke DD, Cornhill JF, Thomas JD, Cosgrove DM. Flow characteristics of aortic cannulae. J Card Surg. July 1995;10(4 Suppl):514-519.2 Minakawa M, Fukuda I, Yamazaki J, Fukui K, Yanaoka H, Inamura T. Effect of cannula shape on aortic wall and flow turbulence: hydrodynamic study during extracorporeal circulation

in mock thoracic aorta. Artif Organs. December 2007;31(12):880-886.

Important Safety Information Care and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery procedures. For a listing of indications, contraindications, precautions, warnings, and potential adverse events, please refer to the Instructions for Use. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.

Soft-Flow®* arterial cannulae are manufactured by MC3, Inc. and exclusively distributed by Medtronic.

Not all products are approved in every geography. For distribution only in markets where Soft-Flow cannula has been approved or cleared.