THE INTRODUCTION for RF DIATHERMY DEVICE
description
Transcript of THE INTRODUCTION for RF DIATHERMY DEVICE
THE INTRODUCTION for RF DIATHERMY DEVICE
JAN. 12, 2009
What is RF diathermy?
Over 100KHz (High Frequency Current, HFC)
Same as Radio Frequency Range → Radio Frequency → RF
Lavatron 420KHZ
RF diathermy History
1886 Development of Radio Frequency Device
1897 Approve the effect of Radio Frequency for Diabetes, Obesity
1899 Report the generating of heat in body tissues by passing RF
1906 Study for the break of tumor tissue by RF
1930 RF diathermy device development
RF Tumor Coagulation RF Lesion Generator
Short wave(10MHz) Diathermy device Physiotherapy Diathermy Treatment
Various RF Device
RF diathermy Principle
Patient plate
Monopolarelectrode
Transformation of Over 100KHz inside body Activation of Ion movement inside of body
Collision between Ion
Generate Core body temperature 40~50°C and 3~5CM depth
→
→ →
- Pole
420 KHZ = Ion inside of body moves 420,000 times movement / sec
+ Pole
Monopolar Type - Lavatron
•Current flows between two poles (Electrode and Patient plate).
Electrode is “+ Pole” and Patient plate is “– Pole”. Current flow from Electrode(+ Pole) to Patient Plate(- Pole).
In the mono polar, heat is generated in the deepest side of body comparing bipolar and tripolar type.
RF diathermy Principle
• It needs separate patient plate and electrode (one is electrode (+pole) and the other is patient plate (-pole)) and current flows between two poles. So the depth of penetration is the deepest among three type of RF.
• The generated heat damages the old collagen and accelerates the regeneration of new collagen by improved metabolism and supplying new nutrition on the body through RF treatment.
• Heat penetrates to the demise area so it melts the cellulite. It is effective to remove fat inside of the body as well.
• With this strong effect on body and face, you can expect visible result right after treatment in your body and face.
Monopolar Type - Lavatron
•+ pole and – pole are in one electrode.
•RF current flows between two poles like above picture. So the patient plate is not required.
• The depth of penetration is fixed and limited to approximately half of the distance between the two poles.
• This means, less energy of sufficient density reaches the deeper skin layers, rendering a more superficial effect regardless of the emitted energy level.
•It is effective on face to remove wrinkle and tightening but it can not touch the fat cell so it is not effective on body.
Bipolar Type
•One + pole and two – poles are in one electrode.
•RF current flows between 3 poles. So current flows between three poles and the penetration depth is a little bit deeper than bi-polar but its depth of penetration is shallower than mono polar RF.
•It touch on superficial area on the skin like bi polar RF. Its basic electricity principle is same with bipolar. With this reason, its result is also similar with bi polar. It is effective on face treatment but it is hard to expect good effect on the body especially removing cellulite.
Tripolar Type
HYPERTHERMIA
Capacitive Electrode Transfer
Lavatron CETLavatron CET
RETRET Resistive Electrode Transfer
Non conductive electrode
INDUCED CURRUNT –Guaranty the Safeness
Go into 3 to 5cm depth deep and wide part,
Good for skin and body care, pain relief
Conductive electrode
Direct CURRUNT – Go into deep but narrow part
Dangerous for burn and damage organ.
For physical therapy, need high power
Body Fat
combustion
Body Fat
combustion
Collagen
Re composition
Collagen
Re composition
Obesity Care Obesity Care
↓ ↓ ↓
Increasing blood flow rate
Expansion of artery and capillary
Increasing core body temperature up to 40~50℃
Biological effect of RF Diathermy
Increase in
O2 supply
Increase in
O2 supply
Increase in
Nutrition supply
Increase in
Nutrition supply
Stimulation of
Immune system
Stimulation of
Immune system
Increase in
Metabolism
Increase in
Metabolism
Removal of
Waste material
Removal of
Waste material
Treatment good for Beauty as well as Health
MAIN APPLICATIONS
FAT CONTROL
PAIN CONTROLWRINKLE REMOVING
HAIR RESTORTION BODY SHAPING
LIFTING
RF Diathermy Body care part
Body Fat Decomposition
Cellulite Dissolving
Size Decreasing
Lifting
Remove Stretch Marks
Abdominal fat care
Size decreasing
Abdominal fat care Before
Abdominal fat care After
Treatment Way -BODY
Lavatron
Meso-therapy
Endermology
Cool Pack
Synergy effect: Lifting, Sliming,
RF Diathermy treatment - Skin care Part
Skin Reproduction
Improvement Wrinkle removing
Relaxing stressed facial muscle
Stimulating Collagen lay
Dissolving Melanin pigment
Acne treatment by sebaceous glands
Facial size decreasing
Dark circle treatment
Crow’s feet removing
Collagen structure before treatment
Collagen structure after treatment
Collagen re composition
SKIN
Lavatron
Treatment
Lavatron
Treatment Aging Aging
Treatment Way - FACE
Lavatron
Meso-therapy
Vitamin C
Cool Pack
Synergy effect: Lifting, Sliming, Anti Aging
Synergy effect: Whitening, Anti Aging
Improvement of Crow’s feet
Lavatron Effect (Before & After) for Face
Improvement of Acne
Improvement of Age spot Improvement of Nasal folds
After 1 session treatment for 10 min. – 40 times magnified image
Crow’s Feet
After 1 session treatment for 10 min. – 40 times magnified image
Forehead
Medical application of RF Diathermy
Shoulder pain
Lumbar pain
Rheumatology
Heat’s deep penetration into tissue
Relaxing stressed muscle by overwork and bad position
Pain Relief
*Chronic arthritis *Muscle pain *Lumbar pain
*Rheumatic arthritis *Frozen shoulder
Application
RF Diathermy treatment - Hair Care Part
Before After
Supplying Oxygen to scalp
Stimulating hair root
Sterilization
Application
• Prevent alopecia, Hair growth, Seborrheic scalp care
Demodex
Hair scarp
Damage hair root, Eat the nutrient material
Hair and Demodex
Special feature of Diathermy Device Lavatron
Auto temperature control function(Patent number: 20-397295)
Auto temperature control function(Patent number: 20-397295)
Treatment lesion monitoring function(Patent number: 20-397295)
Treatment lesion monitoring function(Patent number: 20-397295)
Timer functionTimer function
Various electrode for each treatmentsVarious electrode for each treatments
Guaranty the most safe and effective treatment with below unique feature
Standard ACCESSARIES
100mm 80mm 70mm 60mm 50mm 40mm 30mm 20mm
Optional ACCESSARIES
Pain Relief Electrode-Put the ceramic electrode on the body
without moving.
-Effective for
1) Muscle Relaxation, Pain Relief
2) Promote blood Circulation
3) Increase the metabolism
4) Mind Relaxation
5) Discharge toxin and body wastes
6) Make the skin shining with health
7) Save the labor for rubbing
Optional ACCESSARIES
Hair Electrode- Press the hair electrode around 5 seconds
on the hair scalp. It is the unique electrode
for hair scalp
-Effective for
1) Accelerate blood circulation
2) Increase air supply on the hair scalp
3) Increase hair cream absorption rate
4) Kill the demodex
5) Physical massage effect
6) Evenly supply RF on the hair scalp in
between of hair with 24 points
Size(Diameter)
Appling part Effect Picture
20 ㎜ Wrinkle under eyes, nose, around mouth
Improve wrinkle
30 ㎜ Face, around Cheek and JawImprove wrinkle and skin
care
40 ㎜ Face, Neck, back of neck, arm Skin care and pain relief
50 ㎜ Arm, Calf, Shoulder, ChestBody care, Skin care, Pain
relief
60 ㎜ Calf, Thigh, Back, Chest Body care, Pain relief
70 ㎜ Back, Thigh, abdomenObesity, Body care, Pain
relief
80 ㎜ Back, Thigh, abdomenObesity, Body care, Pain
relief
100 ㎜ Back, Abdomen Obesity, Body care, Pain
relief
Various electrodes
SPECIFICATION
420KHZ
Accessories
LVT-100
Benefit:
-No pain, no side effects
-Remarkably safe and effective for all skin types
-No aftercare service required
Application: Stimulates collagen layer -> Remove fine wrinkle, Increase skin elasticity, Reduce pore size, Lifting
Reduce acne scar and remove acne
Reduce age spot
LVT-100
Special feature of Diathermy Device LVT-100
Auto temperature control function(Patent number: 20-397295)
Treatment lesion monitoring function
Timer function
Five kinds of electrode for treatments
(Patent number: 20-397295)
Temperature setting: 37℃~45℃
Special feature of Diathermy Device LVT-100
Error message be displayed in the LCD window
when the below case is occurred
SPECIFICATION LVT-100
ITEM Description
Main Power 100~240 V auto select
Output Power Max. 70W, Load 500Ω
Output Wave 470kHZ ± 10% Sine wave
Output Power adjust(Auto adjustable and Manual adjustable)
Auto
1 ~ 70 W Auto control
Manual
1 ~100 %(1%/step)
Output time Max. 30 Min.(1min/step)
Active electrodes Ф20 mm, Ф30 mm, Ф40 mmФ50 mm, Ф60 mm
Temperature adjust Auto: 37°C ~ 45°C (1°C step)
RF conductive cream
RF Face care cream
- Retinol: Wrinkle improve
- Adenoisine: Increase elasticity of collagen fiber
- Aloe liquid: High Skin Moisture effect`
RF body cream
- Caffeine: Body fat combustion, Body care
- Aloe liquid: High Skin Moisture effect, Increase metabolism
EuropeEurope
*Italy*Italy
*Spain*Spain
*Portugal*Portugal
*Poland*Poland
*Turkey*Turkey
*Russia*Russia
*Slovenia*Slovenia
*U.S.A*U.S.A
*Mexico*Mexico
*Canada*Canada
*Guatemala*GuatemalaMiddle EastMiddle East
*Iran*Iran
*Egypt*Egypt
U.A.EU.A.E
AsiaAsia
*Hong Kong*Hong Kong
*Thailand*Thailand
*Myanmar*Myanmar
SingaporeSingapore
MalaysiaMalaysia
JapanJapan
ChinaChina
IndonesiaIndonesia
TaiwanTaiwan
KazakhstanKazakhstan
Export 20 countries
Under Process