The Intelligent Choice in Comfort - Aer Conditionat · High seasonal efficiency High seasonal...
Transcript of The Intelligent Choice in Comfort - Aer Conditionat · High seasonal efficiency High seasonal...
TTTTThhhheeee IIIInnnntttteeeellllllliiiiggggeeeennnntttt CCCChhhhooiiccceee iinn CCoommffoorrtt
2
SEER
3
4
Fujitsu General original power diffuser is mounted. Diffuser operates automatically matched to the operation mode to control the optimal airflow. Comfortable space is quickly realized.
During heating operation, vertical airflow provides comfortable floor level heating.
During cooling operation, long-reach airflow is delivered by horizontal airflow, and quickly creates comfortable space up to every corner of the room.
During cooling operation
Cooling
Heating
5
Powerful operation20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.
Setting temp.
Normal mode
Time
Tem
pera
ture
Powerful operation mode
10°C
20°C“10°C HEAT” Button ON
Indoor unit operation START
Noi
se
Ratednoise level
Low noisemode
3dBDown
Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.
For ASYG07 / 09 / 12LMCA
All DC inverter technologyBy All DC inverter control, electricity loss is decreased and power consumption is substantially reduced.
Heat exchanger volume
About 35% UP! than previous model
High efficiencyDC Fan motor
DC Rotary compressor
High density heat exchangerHigh-density 5mm thin tube diameter heat exchanger mounted. Capacity is enlarged including sub heat exchanger. Heat exchange efficiency substantially improved.
Ø5mm
Making the tube thin:7.00
4.10
ASYG09LMCA
Sub heat exchanger
SEER
LLMLMCACAASYASY
7.00
4.00
ASYG12LMCAASYASY LLMLMCACA
SEER SCOP SEER SCOP
The heat load varies greatly depending on the time and season. SEER and SCOP* have been made the standard in tems of actual operating hours throughout the year.*: SEER=Seasonal Energy Efficiency Ratio SCOP=Seasonal Coefficient Of Performance
10°C HEAT operationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied
High seasonal efficiencyHigh seasonal efficiency is realized by adopting DC rotary compressor, All DC inverter control, efficient and high-density heat exchanger technology. New models are achieved "Class A++" in new energy efficiency standard.
Cooling
Set time *max. 9 H
Heating
Max. -4°C Max. +2°C
Set Temp.
Set Temp.
Set time *max. 9 H
6
Program 17:00 ON 24°C
Program 29:00 OFF
Program 318:00 ON 26°C
Program 423:00 OFF
7
9
18
23
Wake up Come back homeGo to work
Go to sleepTimer setting on a certain day
Program timerON/OFF timer can be set four times per day. For example, 2 programs at waking up and going to sleep can be set. Various waste-free programs can be set to match your lifestyle.
Sleep timerThe set temperature is gradually changed automatically to match your bedtime, and economical and pleasant timer operation is performed.
Economy operationEnergy-saving operation can be selected with one touch even at low loads. Low power consumption economical operation is performed by cutting the maximum current.
*Sleep timer setting : 0.5, 1, 2, 3, 5, 7, 9 H
Optional parts
• Wired Remote Controller : UTY-RNNYM
• Simple Remote Controller : UTY-RSNYM
• Communication Kit : UTY-XCBXZ2
• External Connect Kit : UTY-XWZXZ5
N E W
Normal operation
Down
Economy operation
Time
Power consumption
• Wired Remote Controller : UTY-RVNYM
Slim wireless remote controller has an easy-to-view large LCD and a one-touch selection button in simple and easy-to-use layout design.
Set temperature auto return :• The setting temperature automatically returns to the previously
set temperature.• The time range in which the set temperature can be changed is
30 to 120 minutes.
Weekly timer function : • Can be set up to 8 times per day (On / Off, mode,Temp)• 2 pattern settings (i.e. Summer / Winter setting) are available.
Set temperature upper and lower limit setting :• The set temperature range can be set for each operation mode.
(Cooling / Heating / Auto)
Capacity
EERCOP
SEERPdesign
SCOP
Running CurrentAnnual Energy Consumption
Energy Efficiency Class
Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High)
Net Dimension H x W x D
Max Pipe Length (Pre-Charge)Max Height Difference
CoolingHeating
Piping Connections (Small / Large)
Operation Range
Refrigerant (Global Warming Potential)*1: Specifications of ASYG07/14LMCA are provisional for your reference. The contents of formal specifications might be different from these.
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor H/M/L/QOutdoor
Indoor
Outdoor
HighHighHigh
IndoorOutdoor
Heating
Cooling
Cooling
CoolingHeating
Cooling / Heating
Indoor / Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
W/W
W/W
kW
m3/h
I/h
A
kWh/a
dB(A)
mm
V/ Ø/Hz
kW
Specifications
Model No.Indoor unit
Outdoor unit
ASYG09LMCA
AOYG09LMCA230 / 1 / 50
2.5 (0.5 - 3.2)3.2 (0.5 - 4.0)
0.65 / 0.733.854.38
2.5 / 2.47.004.10A++A+
3.2 / 3.51258201.3
43 / 40 / 32 / 21455958
750 / 1670268 x 840 x 203
8.5 (19)535 x 663 x 293
21 (46)6.35 / 9.52
13.8 / 15.8 to 16.720 (15)
15-10~43-15~24
R410A (1,975)
ASYG12LMCA
AOYG12LMCA230 / 1 / 50
3.4 (0.9 - 3.9)4.0 (0.9 - 5.3)
0.97 / 1.023.503.92
3.4 / 3.57.004.00A++A+
4.6 / 4.8170
12251.8
43 / 40 / 32 / 21505961
750 / 1830268 x 840 x 203
8.5 (19)535 x 663 x 293
26 (57)6.35 / 9.52
13.8 / 15.8 to 16.720 (15)
15-10~43-15~24
R410A (1,975)
ASYG14LMCA
AOYG14LMCA230 / 1 / 50
4.0 (0.9 - 4.3)5.0 (0.9 - 6.0)1.17 / 1.355
3.413.69
4.0 / 3.76.703.80A++
A5.6 / 6.3
20913642.1
44 / 40 / 33 / 25496063
750 / 1800268 x 840 x 203
8.5 (19)540 x 790 x 290
34 (75)6.35 / 12.7
13.8 / 15.8 to 16.720 (15)
15-10~43-15~24
R410A (1,975)
Heating (Average)
Heating (Average)
Cooling / Heating (@-10°C)
Auto-changeover : The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
Filter sign : Indicates the filter cleaning period by lamp.
Apple-catechin filter : Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.
Long-life ion deodorization filter : The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
7
Washable panel
Wireless R.C. For ASYG07/09/12LMCA For ASYG14LMCAASYG07LMCA ASYG09LMCA ASYG12LMCA ASYG14LMCA
ASYG07LMCA
AOYG07LMCA230 / 1 / 50
2.0 (0.5 - 3.0)3.0 (0.5 - 3.4)0.470 / 0.685
4.264.38
2.0 / 2.37.104.10A++A+
2.3 / 3.399
7861.0
43 / 40 / 32 / 21456058
750 / 1670268 x 840 x 203
8.5 (19)535 x 663 x 293
21 (46)6.35 / 9.52
13.8 / 15.8 to 16.720 (15)
15-10~43-15~24
R410A (1,975)
Drain Hose Diameter (I.D. / O.D.)
Auto restart : In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored.
Automatic air flow adjustment : The micro-computer automatically adjusts the air flow effectively to follow the changes of room temperature.
i-PAM control models : i-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform.
*1
*1
*1
*1
Up / down swing flaps : The up/down flaps automatically swing up and down.
SEER
Other futures
1111116, 6, SueSuenagnagagagggaggga, a, a, a,a, a,aa TakTakTakTakTakTakTakTakTakatatsu-ku u, Kawasaki 213-8502, Japan http://// www.fujitsu-general.com/CopyCopyright© 2© 013 1 Fujitsu General Limited. All rights reserved. 3EFLM0-1303E
Distributed by :
• Actual products’ colors may be different from the colors shown in this printed material.• Specifications and design subject to change without notice for future improvement. Please check with your dealer.
Fujitsu General (Shanghai) Co., Ltd.
ISO 9001Certified number : 01 100 79269
ISO 14001Certified number : 310102-UK