The flaT uniT series from al-Ko
Donat BrandtPräsident des Plus X Award
Frank KreifVorsitzender der Plus X Award-Jury
AUSZEICHNUNG
Hochachtungsvoll,
Das Produkt
EASYAIRflataus dem Hause
AL-KO THERMwird in den Kategorien
High Quality undÖkologie
mit einem PLUS X AWARD® ausgezeichnet.
EASYAIR_EASYAIRflat.indd 1 10.10.2011 13:06:14
22
All the units are optimised with regard to easy installation. The results of the modular unit construction are compact modules, which are easy to handle. For ceiling installati-ons, these modules can be reduced in weight by removing the built-in components, in order to put it back in after the several modules have been mounted in the ceiling. Thus the modules are very convenient to install. Suitable support con-structions for ceiling installation works are already installed on the unit.
Besides the easy installation, the focus is on an economic operation of the unit. Due to the aerodynamically optimised alignment of the components, in combination with low pressure drops and fans with modern EC technology, a large energy saving operation is achievable. Furthermore a huge amount of energy can be saved by using the heat recovery system.
The can be operated very easily by utilising the control system. The control system guarantees the ener-gy optimised operation of all components.
Thus you will always find the suitable air handling unit for air flow ranges from 650m³/h up to 3.700m³/h.
– The easy way to a good climate
i Easy installation due to click connections of the modules
i Energy saving fan motors in EC technology for lowest energy consumption
i Efficienat heat recovery with a plate heat exchanger
i Easy handling due to intelligent control system as well as modular system design
i High quality manufacturing, reduced maintenance costs
i User-friendly removal of the functional elements is guaranteed by the rapid-connection fittings (for effective maintenance in accordance with VDI 6022)
333
SyStem componentS and applicationS
Counter-current plate heat exchangeri Supply and exhaust air is completely separated
(no cross flow contamination)
i Operation without any odour transfer
i Increased heat recoverage (ca. 80-90 %)
i Reduced maintenance costs
Cross-current plate heat exchangei Supply and exhaust air are completely
separated (no cross flow contamination)
i Operation without any odour transfer
i Increase heat recoverage (ca. 50-60 %)
i Reduced maintenance costs
note: Due to the separation of supply and exhaust
air, the usage of plate heat exchangers for hygienic
systems is possible without any restrictions.
fan with eC motori Maximum motor efficiency
i Compact construction
i Energy efficient operation
i Extended life time
i Low maintenance costs
The modern motor technology of the air handling units ensu-
res quiet and energy efficient operation in all
applications.
44
Supply and exhaust air unit with a counter-current flow, plate heat exchanger
Type air volume1 (m3/h) / efficiency2 (%) / sound power level3 (dB(a)) sfP4 sa/ea Basic unit (mm) a B C D6
mm
sound ab sorption
dB7
Duct connection (mm)5 WeightBasic unit
(kg)
max. connection power8 WWe KWK ele
min nominal max W/m³·s Length5 Width Height mm mm mm Width Height kVA A V kW9 kW10 kW11 A
Gf-01 650 / 84 / 70 1.000 / 82 / 71 1.350 / 80 / 73 614 / 599 1.734 1.326 362 408 918 408 808 20 612 306 220 1,38 6,0 1 x 230 4,7 5,0 5,5 7,9
Gf-02 900 / 84 / 70 1.800 / 80 / 80 1.880 / 80 / 81 941 / 862 1.836 1.326 464 408 1.020 408 808 20 612 408 270 1,84 4,6 3 x 400 8,4 8,9 9,5 13,7
Gf-03 1.350 / 84 / 66 2.700 / 80 / 73 2.840 / 80 / 74 791 / 731 1.938 1.938 464 408 1.122 408 808 20 918 408 366 2,16 5,4 3 x 400 12,7 13,8 14,0 20,2
Supply and exhaust air unit with a cross-current flow, plate heat exchanger
Type air volume1 (m3/h) / efficiency2 (%) / sound power level3 (dB(a)) sfP4 sa/ea Basic unit (mm) a B C D6
mm
sound ab sorption
dB7
Duct connection (mm)5 WeightBasic unit
(kg)
max. connection power8 WWe KWK ele
min nominal max W/m³·s Length5 Width Height mm mm mm Width Height kVA A V kW9 kW10 kW11 A
Pf-01 650 / 55 / 71 1.000 / 52 / 73 1.350 / 52 / 77 910 / 877 1.734 1.326 362 408 918 408 808 20 612 306 216 1,38 6,0 1 x 230 4,7 5,0 5,5 7,9
Pf-02 900 / 59 / 70 1.800 / 57 / 80 2.200 / 57 / 84 948 / 814 2.142 1.326 464 408 1.326 408 808 20 612 408 281 1,84 4,6 3 x 400 8,4 8,9 9,5 13,7
Pf-03 1.350 / 58 / 66 2.700 / 57 / 73 3.300 / 57 / 77 957 / 845 2.346 1.938 464 408 1.530 408 808 20 918 408 397 2,16 5,4 3 x 400 12,7 13,8 14,0 20,2
supply / exhaust air unit
Type air volume1 (m3/h) / efficiency2 (%) / sound power level3 (dB(a)) sfP4 sa/ea Grundgerät (mm) a B C D6
mm
sound ab sorption
dB7
Duct connection (mm)5 WeightBasic unit
(kg)
max. connection power8 WWe KWK ele
min nominal max W/m³·s Length5 (a+C) Width Height mm mm mm Width Height kVA A V kW12 kW10 kW13 A
ef-01 650 / 68 1.000 / 68 1.700 / 73 567 816 662 362 408 - 408 808 20 612 306 58 0,81 3,5 1 x 230 11,4 5,0 8,1 11,7
ef-02 900 / 69 1.800 / 79 2.750 / 87 654 816 662 464 408 - 408 808 20 612 408 68 1,12 2,8 3 x 400 20,5 8,9 14,6 21,1
ef-03 1.350 / 64 2.700 / 72 3.700 / 80 608 816 968 464 408 - 408 808 20 918 408 85 1,28 3,2 3 x 400 30,8 13,8 21,9 31,6
technical data
Performance data
Top view GR / PF unit with plate heat exchanger
Type Pf:
Heat recoverage with a
cross-current plate heat
exchanger
Type Gf:
Increased heat reco-
verage with a counter-
current plate heat
exchanger
1 External pressure loss supply air 200 Pa, exhaust air 200 Pa 2 Efficiency of heat recovery according to DIN EN 308
(without condensation) 3 Sound power level in the supply air duct
4 Specific Fan Power (SFP) in accordance with EnEV 2009 at nominal air
volume and external duct pressure losses supply air 200 Pa, exhaust air 200 Pa,
incl. filters (F7 / F5)5 With duct connections (option), the unit length increases on both sides about 102 mm
102 D A C D 306 408 306B
102 D A C D 306 408 306B
Heating-module, warm water WWE (optional)
Heating-module, warm water WWE (optional)
Cooling-module, incl. TA cold water KWK (optional)
Cooling-module, incl. TA cold water KWK (optional)
Electrical, heating module ELE (optional)
Electrical, heating module ELE (optional)
waste air
waste air
Wid
thW
idth
outdoor air
outdoor air
extract air
extract air
supply air
supply air
Length
Length
To get current, detailed technical data please use EASYAIRselect: http://easyair.al-ko.de
55
Supply and exhaust air unit with a counter-current flow, plate heat exchanger
Type air volume1 (m3/h) / efficiency2 (%) / sound power level3 (dB(a)) sfP4 sa/ea Basic unit (mm) a B C D6
mm
sound ab sorption
dB7
Duct connection (mm)5 WeightBasic unit
(kg)
max. connection power8 WWe KWK ele
min nominal max W/m³·s Length5 Width Height mm mm mm Width Height kVA A V kW9 kW10 kW11 A
Gf-01 650 / 84 / 70 1.000 / 82 / 71 1.350 / 80 / 73 614 / 599 1.734 1.326 362 408 918 408 808 20 612 306 220 1,38 6,0 1 x 230 4,7 5,0 5,5 7,9
Gf-02 900 / 84 / 70 1.800 / 80 / 80 1.880 / 80 / 81 941 / 862 1.836 1.326 464 408 1.020 408 808 20 612 408 270 1,84 4,6 3 x 400 8,4 8,9 9,5 13,7
Gf-03 1.350 / 84 / 66 2.700 / 80 / 73 2.840 / 80 / 74 791 / 731 1.938 1.938 464 408 1.122 408 808 20 918 408 366 2,16 5,4 3 x 400 12,7 13,8 14,0 20,2
Supply and exhaust air unit with a cross-current flow, plate heat exchanger
Type air volume1 (m3/h) / efficiency2 (%) / sound power level3 (dB(a)) sfP4 sa/ea Basic unit (mm) a B C D6
mm
sound ab sorption
dB7
Duct connection (mm)5 WeightBasic unit
(kg)
max. connection power8 WWe KWK ele
min nominal max W/m³·s Length5 Width Height mm mm mm Width Height kVA A V kW9 kW10 kW11 A
Pf-01 650 / 55 / 71 1.000 / 52 / 73 1.350 / 52 / 77 910 / 877 1.734 1.326 362 408 918 408 808 20 612 306 216 1,38 6,0 1 x 230 4,7 5,0 5,5 7,9
Pf-02 900 / 59 / 70 1.800 / 57 / 80 2.200 / 57 / 84 948 / 814 2.142 1.326 464 408 1.326 408 808 20 612 408 281 1,84 4,6 3 x 400 8,4 8,9 9,5 13,7
Pf-03 1.350 / 58 / 66 2.700 / 57 / 73 3.300 / 57 / 77 957 / 845 2.346 1.938 464 408 1.530 408 808 20 918 408 397 2,16 5,4 3 x 400 12,7 13,8 14,0 20,2
supply / exhaust air unit
Type air volume1 (m3/h) / efficiency2 (%) / sound power level3 (dB(a)) sfP4 sa/ea Grundgerät (mm) a B C D6
mm
sound ab sorption
dB7
Duct connection (mm)5 WeightBasic unit
(kg)
max. connection power8 WWe KWK ele
min nominal max W/m³·s Length5 (a+C) Width Height mm mm mm Width Height kVA A V kW12 kW10 kW13 A
ef-01 650 / 68 1.000 / 68 1.700 / 73 567 816 662 362 408 - 408 808 20 612 306 58 0,81 3,5 1 x 230 11,4 5,0 8,1 11,7
ef-02 900 / 69 1.800 / 79 2.750 / 87 654 816 662 464 408 - 408 808 20 612 408 68 1,12 2,8 3 x 400 20,5 8,9 14,6 21,1
ef-03 1.350 / 64 2.700 / 72 3.700 / 80 608 816 968 464 408 - 408 808 20 918 408 85 1,28 3,2 3 x 400 30,8 13,8 21,9 31,6
Top view EF unit supply air / exhaust air
options
options
options
6 Acoustic silencer module (optional)7 Integrated silencer for acoustic levels of 250 Hz8 Without power for optional electric air heater 9 Heating capacity for temperature difference 14 K, medium 50 / 35 °C
10 Cooling capacity for temperature difference 10 K, medium 6 / 12 °C11 Heating capacity for temperature difference 14 K, 400 V / 50 Hz12 Heating capacity for temperature difference 34 K, medium 50 / 35 °C13 Heating capacity for temperature difference 34 K, medium 50 / 35 °C
102 DA D 306 408C 306
Heating-module, warm water WWE (optional)
Cooling-module, incl. cold water KWK (optional)
Electrical, heating module ELE (optional)
supply air
waste air
Wid
th
6
6
– Unit design and options
unit sizes air handling units are available in several
unit sizes. You can see the different unit sizes and the related performance data on page 4 and 5.
service and connection sideMaintenance of can be done from the ground by opening the large maintenance doors. The connection side for the medium supply (electricity, hot and chilled water)
DamperAs an option for the there in an external air-tight damper (tightness class 2) available.
A B
102
C
306 408
Breite
Länge
E K TA
Description K10 K20 K30
Width (mm) 612 612 918
height (mm) 306 408 408
length (mm) 102 102 102
Weight (kg) 3 4 5
Damper
A B
102
C
306 408
Breite
Länge
E K TA
Description V10 V20 V30
Width (mm) 662 662 968
height (mm) 361 463 463
length (mm) 408 408 408
Weight (kg) 28 35 52
fan module fan modulePlug fans with backward curved blades are used as fans. The motors are equipped with modern EC technology and operate very energy efficient (IE3).
can be chosen. F. e.: the service side in supply air direction right conforms to the demonstration given on page 4 and 5.
hygienical standardsAll air handling units are constructed according to the European guideline VDI 6022. The casing is powder coated on the inside and outside surfaces (hygienically non-hazardous) thus it provides a high corrosion protection as well.
heat recovery moduleFor an energy efficient operation of the air handling unit you can select two different plate heat exchangers for heat recoverage. A cross-current plate heat exchanger creates economi cal, increased the level of heat recoverage for projects which have to be carried out within limited budgets. The counter-current plate heat exchanger is an optimal alternative if the highest possible energy efficiency is the main criteria. By utilising these heat recovery systems you can save heating energy without mixing air streams. For that reason this system can be used even when the extract ambient air is slightly contaminated by odours or other organic components.
Description WD10 WD20 WD30
Width (mm) 1.326 1.326 1.938
height (mm) 361 463 463
length (mm) 918 1.326 1.530
Weight (kg) 86 108 162
Cross-current plate heat exchanger
Abluft
Abluft
Zuluft
Zuluft
ZuluftAußenluft
Außenluft
Außenluft
Fortluft
Fortluft
Description WG10 WG20 WG30
Width (mm) 1.326 1.326 1.938
height (mm) 361 463 463
length (mm) 918 1.020 1.122
Weight (kg) 93 133 166
Counter-current plate heat exchanger
filter moduleAs standard, the is supplied with high efficient air filters. In the supply air there is a F7 and in the exhaust air there is a F5 filter installed. The quality of the filters is according to VDI 6022.
Description f10/f11
f20/f21
f30/ f31
filter class F5 / F7 F5 / F7 F5 / F7
Width (mm) 662 662 968
height (mm) 361 463 463
length (mm) 408 408 408
Weight (kg) 15 / 15 18 / 18 28 / 28
filter module
A B
102
C
306 408
Breite
Länge
E K TA
7
7
electric heating moduleEach can be purchased with an electric heating coil. The power supply is 400V/50Hz. The heating coil is installed directly on the air outlet (supply air side) of the unit. Thus the required supply air temperature can be always achieved.
silencer (sound absorber)An optional silencer module can be ordered for the
- unit to further reduce the acoustic emissions in the ducting/channel networks.
Control system air handling units are equipped with
complete control system as standard. All field devices are installed on the unit. The controller as well as the operation panel is located in a separate control cabinet. This cabinet can be installed at any location where it is required. The wiring must be done on-site. The basic function of the
control system is an extract air temperature control. Further functions for energy efficient operations are included in the control system respectively can be
selected as an option (refer to ordering key). As an option they can be purchased without a control system as well.
silencer
Description sD 10 sD 20 sD 30
Width (mm) 662 662 968
height (mm) 361 463 463
length (mm) 808 808 808
Weight (kg) 24 27 35
Duct connectionFor all units sound decoupled canvas duct connections are available. With these duct connections the duct is perfectly decoupled from the air handling unit concerning sound and vibrations.
Description s10 s20 s30
Width (mm) 612 612 918
height (mm) 306 408 408
length (mm) 102 102 102
Weight (kg) 1 2 3
A B
102
C
306 408
Breite
Länge
E K TA
Duct connection
heating moduleEach can be purchased with a hot water heating coil. The heating coil consists of copper tubes with aluminium fins and can be installed directly on the air outlet of the unit. Thus the required supply air temperature can be always achieved.
A B
102
C
306 408
Breite
Länge
E K TA
heating module
heating moduleWe10/We11
We20/We21
We30/We31
Width (mm) 662 662 968
height (mm) 361 463 463
length (mm) 306 306 306
Weight (kg) 14 / 17 18 / 21 27 / 32
Cooling moduleEach can be purchased with a chilled water cooling coil. The cooling coil consists of copper tubes withaluminium fins and can be installed directly on the air outlet (supply air side) of the unit. To prevent a condensate carry- over into the duct, the cooling module is equipped with an integrated drip separator.
DescriptionWK10/WK11
WK20/WK21
WK30/WK31
Width (mm) 662 662 968
height (mm) 356 458 458
length (mm) 408 408 408
Weight (kg) 22 / 22 28 / 28 42 / 42A B
102
C
306 408
Breite
Länge
E K TA
Cooling module
A B
102
C
306 408
Breite
Länge
K TA
electric heating module
Descriptionel10/el11
el20/el21
el30/el31
Width (mm) 662 662 968
height (mm) 356 458 458
length (mm) 306 306 306
Weight (kg) 25 / 32 35 / 39 46 / 53
i WWe (option)
Heating module (hot water)
i KWK (option)
Cooling module with drip sep.
(chilled water)
i ele (option)
Heating module (electric)
i WKe (option)
Heating module (hot water)
Cooling module with drip sep.
(chilled water)
i eKe (option)
Heating module (electric)
Cooling module with drip sep.
(chilled water)
i o: without duct connections
i Z: with duct connections
Pf-/Gf-unit:
i 75: Supply air F7, exhaust air F5
i e75: Supply air F7, exhaust air
F5 incl. spare filters
ef-unit:
i 7X: Supply air F7
i X5: Exhaust air F5
i e7X: Supply air F7
incl. spare filters
i eX5: Exhaust air F5
incl. spare filters
i mK: with external damper
i oK: without external damper
i r: Medium connection right
i l: Medium connection left
i unit type and size refer to page 4 / 5
12/2
011;
Sub
ject
to te
chni
cal m
odifi
catio
ns.
Gf-o2-r-75-mK-sD11-0-hhh
Order code
Control system:
i -ra = Room sensor
i -DK = Constant
pressure control
i -VK = Constant air volume
control
i -aQ = AL-KO air quality
control in the
exhaust duct
i -rC = Remote control with
10m cable
i -Bl = Bus module LON
i -Bm= Bus module Modbus
i -BB = Bus module Bacnet /
Ethernet
i -CX = Without control
system / without
field devices
al-Ko Therm GmBh
Bereich luft- und Klimatechnik
Hauptstraße 248 – 250
89343 Jettingen-Scheppach
Germany
Fon +49 8225 39-0
Fax +49 8225 39- 2113
www.al-ko.com
The easy way to EASYaiR®
http://easyair.al-ko.de
i sD 00: Without silencer
i sD 01: With a silencer
module on the exhaust/
outgoing air connection
i sD 10: With an extended
silencer module on the
external/incoming air
connection
i sD 11: With a shortened
silencer module on the
external air /incoming
air connection and on
the exhaust/outgoing air
connection