The Best Defense Against Cross-Contamination against cross-contamination with a two in one fi lter...

6
The Best Defense Against Cross-Contamination Protecting both patient and machine

Transcript of The Best Defense Against Cross-Contamination against cross-contamination with a two in one fi lter...

Page 1: The Best Defense Against Cross-Contamination against cross-contamination with a two in one fi lter design Co-Axial design promotes thermal effi ciency during procedures Flex hose is

The Best Defense Against Cross-ContaminationProtecting both patient and machine

Page 2: The Best Defense Against Cross-Contamination against cross-contamination with a two in one fi lter design Co-Axial design promotes thermal effi ciency during procedures Flex hose is

KingF2 Filter™Over time, we have revolutionized our circuit design to include the highest performing fi lter which protects

both the patient and the machine from bacterial and viral cross-contamination such as TB. We offer

phthalate/DEHP/Latex free materials with our patients’ well-being in mind.

Protects both machine and patient against cross-contamination with

a two in one fi lter design

Co-Axial design promotes thermal effi ciency during procedures

Flex hose is shapeable and reduces the amount of torque and weight at the patient end

Expandable fl ex hose design collapses the circuit to 1/3 its size, allowing for easier

packaging and storage

Our dual chambered fi lter provides

separate protection of the inspiratory

gases (blue) and the expiratory gases

(red) in one unique fi lter. This helps

reduce the risk of bacterial and viral

cross-contamination such as TB.

The co-axial design

helps keep the patient

normothermic as the warm

expiratory gases (red) warm

the cool inspiratory

gases (blue).

Page 3: The Best Defense Against Cross-Contamination against cross-contamination with a two in one fi lter design Co-Axial design promotes thermal effi ciency during procedures Flex hose is

1978Dual limb circuits

introduced

1990Sweet Dreams

Scented face masks

1992Universal F Circuit

“ ”

Since 1978 Ambu King Systems has been a leading supplier and innovator in anesthesia disposables. Innovations include the fi rst co-axial circuit, dual chamber high effeciency fi lter, contour breathing

bag, and scented masks.

King F Flex™Similar to the Flex2, the King F Flex is a single limb

co-axial expandable circuit that promotes thermal

effi ciency. However, unlike the KingFlex2, this circuit

features a disposable manifold.

Dominated the market;

being made from

clear plastics

First co-axial anesthesia

circuit introduced to

the world

KingFlex2™Filter protects both patient and machine (inspiratory and

expiratory machine ports) with a single, dual-chamber,

high effi ciency fi lter. Effi cient at removing 99.99% of

bacteria and viruses. Offers the ability to shape the fl ex

tubing near the airway and ability to compress/expand

fl ex tubing to ideal length between patient and machine

reduces the torque on the airway device. (Reference the

back of the brochure for more fi lter effi ciency details,

and for sizes of common bacteria and viruses.)

Sweet Dreams scented face

masks and colored pediatric

breathing bags

Ambu King Systems History of Innovation

Page 4: The Best Defense Against Cross-Contamination against cross-contamination with a two in one fi lter design Co-Axial design promotes thermal effi ciency during procedures Flex hose is

1998Universal F2 Circuit

2004Universal Flex2

Circuit

2010Universal F Flex

Circuit

50

45

40

35

30

25

20

15

10

5

0

Cubic

-Feet

72” KING “FLEX” SINGLE-LIMB

(50 circuits per 6.0 cu-ft case)

72” FLEX TWO-LIMB(30 circuits per 4.5 cu-ft case)

72” CORRUGATED SINGLE-LIMB

(30 circuits per 6.0 cu-ft case)

72” CORRUGATED TWO-LIMB

(20 circuits per 4.5 cu-ft case)

Cubic-Feet of Storage for 200 CircuitsSignifi cantly Less Space for Flex Tubing

King 2-Limb Ultra-Flex™Reduces the number of circuit lengths stocked, due

to fl ex tubing being expandable to multiple lengths.

Signifi cantly less storage space required, because fl ex

tubing is packaged at its most compressed length.

Introduced the fi rst and only

expandable co-axial circuit paired with

the dual chambered F2 fi lter

Introduced the fi rst and only

expandable co-axial circuit paired with

disposable manifold

First co-axial anesthesia

circuit with the dual

chamber F2 Filter

24 ft3

30 ft3

40 ft3

45 ft3

Page 5: The Best Defense Against Cross-Contamination against cross-contamination with a two in one fi lter design Co-Axial design promotes thermal effi ciency during procedures Flex hose is

Anesthesia Delivery Products Designed for Children

KingBreathing Bags™

Our breathing bags provide a secure attachment to the

machine as well as a good feel of lung compliance. The

rigid material of the bag bushing allows for consistent

bag tolerance when infl ated. Effi ciently delivers required

gas volume with less hand fatigue due to thin and

pliable bag material, and also due to the shape of the

Contour bag.

Operation KidStuff™ is the remedy to pre-surgery anxiety in children. Ambu offers brightly colored Rainbow Bags and scented Sweet Dream Masks. Just show the child the bright breathing bag “balloon” and let them smell the scented mask. They can select which colored bag and scented mask they like best and hold those items as they are wheeled to the OR.

Operation KidStuff bags and masks have been shown to help reduce a child’s observable anxiety after they are separated from their parents.

Ambu also offers the co-axial Pediatric F2 breathing circuit, designed specifi cally for pediatric patients.

Cherry

Strawberry

Bubble Gum

Fresh Scent

KingMasks™Our masks provide an excellent face seal with an

extremely pliable and tacky cushion. The ribs located

on the top of the cushion provides a no slip grip. King

Masks contain no DEHP or phthalates and are MRI safe.

Page 6: The Best Defense Against Cross-Contamination against cross-contamination with a two in one fi lter design Co-Axial design promotes thermal effi ciency during procedures Flex hose is

NameBacteria, Virus, or

Particulate

Flex2 Filter

Efficiency3

Bacteria/Virus/

Particulate

Average Size (um)

Transmission of Diseases

(actual or in tests)1,2

Staphylococcus aureus TEST bacteria 99.9999% 0.90 diameter airborne water droplets

Neisseria meningitidis bacteria --- 0.80 diameter airborne water droplets

Bacillus anthracis bacteria --- 6.50 length1.15 diameter airborne water droplets

Myobacterium tuberculosis bacteria --- 2.75 length0.35 diameter airborne water droplets

Phi X174 TEST virus 99.9996% 0.027 diameter airborne water droplets

Flu type A- H1N1 & H3N2 virus --- 0.100 diameter airborne water droplets

Flu type B- Victoria & Yamagata virus --- 0.100 diameter airborne water droplets

Norovirus virus --- 0.030 diameter airborne water droplets

Inert particulate for HEPA testing TEST particulate >99.97% 0.300 diameter dry particulate only

References/Studies:1. Transmission by water droplets per ASTM F2101 test method, CDC Principles of Epidemiology, and Boston University ”Transmission of Infectious Disease”.2. Examples of diseases spread by airborne respiratory water droplets. Boston University ”Transmission of Infectious Disease” and Wikipedia-Airborne-Disease.3. Testing and reported results by Nelson Laboratories

Ambu Inc.6230 Old Dobbin LaneColumbia, MD 21045Tel. 800 262 8462Fax 800 262 8673ambuUSA.com 4

96 5

015

31

- V0

1 -

02/2

020

- A

mbu Inc.

Tech

nic

al d

ata

may

be

mo

dif

ied w

itho

ut

furt

her

noti

ce. TC

C 10

376

Part # Type Size Design CO2Port

Volume

(ml)

Weight

(g)

Resistance

(cm H2O)

Absolute

Humidity (mg/l)

Bacterial/

Viral

Efficiency*

0.3um Particulate

Efficiency **

F2 Dual Filter FILTER DUAL Straight No 149 60 1.0 @ 0.5 l/s n/a 99.9999% >99.97%

20801 FILTER STND Straight No 75 29 0.9 @ 0.5 I/s n/a >99.99% ---

MS-112 FILTER STND Straight Yes 37 22 0.6 @ 0.5 l/s n/a 99.99% ---

GVS-4244HEPA

HMEFSTND Straight Yes 52 40 1.4 @ 0.5 l/s 30 @ 500ml Vt 99.9999% >99.97%

MS-121 HMEF LRG(ICU) Straight Yes 95 45 1.4 @ 0.5 l/s 38 @ 1000ml Vt 99.999% ---

GVS-4333 HMEF STND Straight Yes 55 27 1.4 @ 0.5 l/s 34 @ 500ml Vt 99.999% ---

MS-111 HMEF STND Straight Yes 55 34 1.1 @ 0.5 I/s 38 @ 1000ml Vt 99.99% ---

MS-113 HMEF STND Angled Yes 61 35 1.4 @ 0.5 l/s 38 @ 1000ml Vt 99.99% ---

KN-HMEF HMEF SML Straight Yes 38 25 2.5 @ 0.5 I/s 31 @ 500ml Vt >99.99% ---

MS-101 HMEF PED Angled Yes 15 10 1.4 @ 0.5 l/s 35 @ 100ml Vt 99.99% ---

MS-120 HME LRG(ICU) Straight Yes 95 44 1.4 @ 0.5 l/s 38 @ 1000ml Vt --- ---

MS-110 HME STND Straight Yes 55 33 1.4 @ 0.5 l/s 38 @ 1000ml Vt --- ---

MS-102 HME SML Straight No 22 13 1.1 @ 0.5 I/s 35 @ 500ml Vt --- ---

MS-131 HME TRACH O2 Port No 13 6 1.4 @ 0.5 l/s 34 @ 500ml Vt --- ---

MS-133 HME TRACHO2 Port &

ValueNo 13 6 1.4 @ 0.5 l/s 34 @ 500ml Vt --- ---

* Bacterial and efficiency determined per test method ASTM F2101, which simulates the actual airborne transmission of Staphylococcus aureus in water droplets.6

Viral efficiency per test method ASTM F2101, which simulates the actual airborne transmission of bacteriophage phi x174 in water droplets.6

** Particulate efficiency determined per Nelson Laboratories’ test protocol, which transmits dry and inert 0.3um airborne particulates. An efficiency of 99.97% is a requirement for

a filter to be rated as HEPA

Filter and HME Descriptions and Performance Data

Data on Common Bacteria and Viruses- Including Those Used for Filter Efficiency Tests

US: Rx only