th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO...

13
TREX meeting 27 th of November 2019 VELO vacuum system status On behalf of the VSC Josef Sestak

Transcript of th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO...

Page 1: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

TREX meeting 27th of November 2019

VELO vacuum system statusOn behalf of the VSC – Josef Sestak

Page 2: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Overview of the activities

Additional sectorisation of the IP8.X;

Activities motivated by VELO upgrade;

Activities motivated by SMOG 2;

Already presented, discussed and

approved:

o TREX #19;

o LHCb Technical Committee 12/2018;

o IWG (multiple times);

Page 3: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Additional sectorisation

• Existing sectorisation of IP8.X (RB84 – RB86);

11/27/2019 Document reference 3

Page 4: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Additional sectorisation

• Existing sectorisation of IP8.X (RB84 – RB86);

11/27/2019 Document reference 4

Page 5: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Additional sectorisation

• Prepare UX85 space reservation upstream of the VELO;

11/27/2019 Document reference 5

• Removal of the angle valve GV302;

• New sector valve as close to IP8 as possible;

• Aperture issue (valve ID63 – VELO ID80;

Page 6: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Additional sectorisation

• Aperture – we were lucky; VELO elliptical head has

been modified during the production (Nikhef – Thermo).

11/27/2019 Document reference 6

Page 7: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Additional sectorisation

11/27/2019 Document reference 7

• Old transition removed and geometry reconstructed

• New transition (VELO 54mm – Sector valve 63mm)

• Produced and available for installation in 2020

54mm 63mm

Page 8: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Additional sectorisation

11/27/2019 Document reference 8

Gate valve ID150

Sector valve VVGST ID63

HiPace 700 turbo-molecular pump

Standard module

ID80/63 with RF contact

Transition chamber ID63/54

• New configuration increase the available space;

• Smooth aperture transition;

• VELO protection cover needs to be modified;

• Equipment available for installation in 2020.

Page 9: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Activities motivated by VELO upgrade

• Extension of the VELO differential pressure control unit;

• Modification of the GIS lines;

11/27/2019 Document reference 9

Additional

pressure-switch

Design and production of two new vacuum hubs

Production ongoing – will be ready by beginning of 2020

Spare pressure

switches to be

ordered

Modification of the GIS lines to make

space for CO2 cooling system

• To be scheduled (Q1 2020)

Page 10: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Activities motivated by SMOG 2

11/27/2019 Document reference 10

Design and production of custom flange for Storage cell connection

Production ongoing – will be ready by beginning of 2020

All-metal right angle UHV valve (DN10) – Storage cell injection

Equipment available for installation

Custom DN10 capillary – production by Q1 2020

Instrumented pumping group

Penning + Pirani gauge;

PV503 – SMOG injection;

Connection to Neon injection line;

Connection to SMOG injection line;

Current SMOG inlet

(will be used for connection after the LS2)

Page 11: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Activities motivated by SMOG 2

• Installation of the GFS line;

• Installation of the GFS table;

• Position on the balcony next to the current GIS;

• GIS table needs some small modifications (BVO);

• Bypass from the SMOG to GFS;

• Feasible during the YETS period.

11/27/2019 Document reference 11

Expected by 2020

Run 3

Page 12: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Additional activities

• Installation of the RGA with long-range cables;

• Inspection of the components related with

corrosion issue on the VELO vacuum system;

• Relocation of the calibrated Bayard-Alpert gauge

closer / on the VELO (ECR LHC-VGI-EC-0001).

11/27/2019 Document reference 12

Page 13: th of November 2019 VELO vacuum system status · 2019. 12. 1. · Activities motivated by VELO upgrade • Extension of the VELO differential pressure control unit; • Modification

Thank you for your attention

11/27/2019 Document reference 13