TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

22
TFX Ultra Clamp-on Ultrasonic Flow Meter

description

Presentation featuring technical information and options available for Dynasonic's TFX Ultra clamp-on ultrasonic flow meter. It also describes a number of application case studies.

Transcript of TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Page 1: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

TFX UltraClamp-on Ultrasonic Flow Meter

Page 2: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Model TFX Ultra Rugged, all inclusive

output options

Compact integral mount system for pipes 2” (50.8 mm) and smaller

Remote mount system for pipe sizes ½” (12.7 mm) and higher

Integral mount shown here.Integral transducers available in PVC (standard) or optional CPVC

Page 3: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

• New generation of transit time flow meter:• Increased transmit power by over 3x• Compatible with ALL transducer types (do not need separate boards)• USB interface to PC (for UltraLink software) • Backlit LCD• Easier wiring (compared with TFXL)• CE mark

• 1% of reading accuracy• Measuring range -40 – 40 FPS (-12 – 12 MPS)• NEMA 4 (IP65); aluminum enclosure• CSA Class I Div. 2 / ATEX II 2 G Ex nA II T4

TFX Ultra Features

Page 4: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Other Notable Features/Improvements: Standard A/B USB programming connection Field replaceable fuse (resettable on DC powered) Optional keypad Universal AC (95-230VAC) power option Display backlighting Keypad/UltraLink configure for 500 kHz, 1 MHz or

2 MHz transducers Remote totalizer reset (via ModBUS, N.O. switch, or IP if equipped)

“GREEN” utilizes less than 5 watts (typical, 3x less than Onicon)

TFX Ultra

Page 5: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Flow Meter Model

Two Transmitter Types: Energy Model (BTU)

Page 6: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Outputs & Communications Standard

Energy and Flow Meter Models 4-20mA (sourcing) RS485 Modbus RTU Communications (2-wire)

Flow Meter Model only, also has: Frequency Output (1000 Hz, open-collector) Dual Alarm Outputs; high/low flow, batch, errors (open-collector)

Optional Ethernet: Modbus TCP/IP, EtherNet/IP and BACnet/IP Totalizing Pulse Output; isolated open-collector

Page 7: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

TFX Ultra

Optional TFXB is available with Intrinsically Safe barrier,CSA Class I Div. 1

Page 8: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

DTTS ½” to 2” (12 to 50 mm) Easy/quick installation, transducers

custom fit to ANSI pipe, Copper Tubing, or Rigid Tubing specs

Cable lengths to 990 ft (300 meters) Flexible armored conduit option Rated to NEMA 6 (IP-67) Available in PVC for maximum fluid

temperature +185 °F (+85 °C) And CPVC for maximum fluid

temperature +250 °F (+121 °C) ½” and ¾” versions are 1% F.S. accuracy

Transducer Options

Page 9: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

DTTN Pipe sizes 2” [50 mm] and above Versatile mounting options Cable lengths to 990 ft (300 meters) Flexible armored conduit option Rated to NEMA 6 (IP-67); optional

NEMA 6P (IP-68) Maximum fluid temps to +250 °F

(+121 °C)

Transducer Options

Page 10: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Transducer OptionsDTTH

High Temp: maximum fluid temps to +350 °F (+176 °C)

Pipe sizes 2” [50 mm] and above Versatile mounting options Cable lengths to 990 ft (300 meters) Flexible armored conduit option Rated to NEMA 6 (IP-67) Includes high-temp couplant

Page 11: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Transducer OptionsDTTL* Pipe sizes 24” [610 mm] and above Versatile mounting options Cable lengths to 990 ft (300 meters) Flexible armored conduit option Rated to NEMA 6 (IP-67);

optional NEMA 6P (IP-68) Maximum fluid temps to +250 °F

(+121 °C) Also recommended for pipe sizes 4”-24”

(100-610 mm), if applicationparameters are not ideal.

* Used with TFX Ultra and DXN only, 500 kHz configuration

Page 12: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

ApplicationsConserve Thru ControlNorth Adams, MAGeo Thermal Application

TFX Ultras used to measure and control geo-thermal HVAC system. EPA also requires building owner to report ground water usage.

Well water can carry dirt and ice which destroys inline meters.

Page 13: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Client: Valley Water – Plainville, CT. Municipal Water ApplicationHigh velocity – no straight runs TFX Ultra replaced 901 DopplerResult: Improved accuracy

Applications

Page 14: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

P&G Gillette Beauty & GroomingBoston, MA

Gillette’s sustainability project requires measurement and control of city water and process loops in 100 year old plant. Potential sale for 17 measurement points. Most lines cannot be shut down without halting production.

Applications

Page 15: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Ulster Uniform ServiceKinston, NYIndustrial Laundry

Since a high percentage of the water is evaporated through their dryers, Ulster uses a TFX Ultra meter to report waste water usage to save on their sewage bill.

Applications

Page 16: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Mercedes-Benz plant, Istanbul, TURKEY

Challenge:Customer dissatisfied with in-line BTU meters to measure energy

use through their 15 cogeneration lines. Considered to be high maintenance and were not thought to be reliable.

Solution: TFXE w/ DTTN, Clamp-on RTDsEasy installation, no process shut-down, and seamless drop-in to

their Siemens SCADA system via standard Modbus RTU were seen as key advantages in selecting Dynasonics.

Page 17: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics
Page 18: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics
Page 19: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics
Page 20: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Genoa, Illinois WWTP

Use clamp-on meters to prove output and performance of new pump; DFX Doppler and Transit time TFX Ultra both utilized, due to suspected pump cavitation. Meters showed a disparity, helped identify debris caught within the pump.

Page 21: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics
Page 22: TFX Ultra Clamp-on Ultrasonic Flow Meter from Dynasonics

Thank you

+44 (0)1280 817304 [email protected] www.badgermeter.co.uk

Bell Flow Systems are the UK representative for Badger Meter