Tests Operacionales en...

39
Tests Operacionales en Radiografía Mauricio Vergara Clínica del Country, 2015

Transcript of Tests Operacionales en...

Page 1: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Tests Operacionalesen Radiografía

Mauricio VergaraClínica del Country, 2015

Page 2: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Electronesacelerados Tungsteno

Positivo(anodo)

Negativo(catodo)

FOTONESCalorelectrones

Ampolla de vidrio

Circuito deAlta tensión

Circuito delfilamento

100 mA200 mA300 mA

Reloj seg

Funcionamiento

Page 3: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

FOTONESEnergía: circuito kV

N°: circuito mAs

Page 4: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

22 cm

28cm

28cm

110 kV, 5 mAs

110 kV, 5 mAs

110 kV, 12 mAs

Page 5: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

DetectorIMAGEN

AEC

Tubo RX

fotones

Paciente

fotones CI

tiempo mAs

N° fotonesemergentes(ajuste densidad)

Control de Exposición Automático

Page 6: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Tests Operacionales en RX

• Tests Operacional: certificar que el equipo opera “normalmente” y genera imágenes en rangos de calidad clínica

• Test Aceptación: certificar que las especificaciones técnicas actuales del equipo son compatibles con las originales

Page 7: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

RX

Grilla AEC Detector

generador mAskV

gain DOSIMETROkVmAsGain

VISUALColimadorGrilla

Page 8: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

kVDosis : mGy, Gy, nGyTiempo: sec, msec

Page 9: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Generador kVp

Tubo RX

dosímetro

Separador10 cm

mesa

nominal

medido difercia%

50 kVp

80 kVp

110 kVp

Page 10: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Filamento mAs vs Dosis

Tubo RX

dosímetro

Separador10 cm

mesa mAs Gy

80 kVp

6

80 kVp

20

80 kVp

30

Page 11: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Colimación

campo Luz15 cm x 15 cm

Campo radiación 16 cm x 16 cm máximo

delimitadordetector

mesa

Tubo RX 50 kV, 6 mAs

Page 12: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Colimación

Page 13: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

mesa

detector

Alineacion Tubo RX - Detector

Page 14: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del
Page 15: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Histograma FantomaColumna Lumbar

81 kV 1.87 mAs

Page 16: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

OBSERVACIONES

• kVp y mAs con registros OK. Equipo RX OK• Ajuste de Densidad con valores asimétricos• Ajuste ganancias AEC: valores muy altos y

diferentes en mesa y mural (detector central)

• Histograma con forma OK. mAs muy bajo. Imagen OK

• No hay antecedentes de registros de kVp, mAs, AEC e Histogramas para comparar

• No hay especificaciones de grillas y detector

Page 17: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

CIRS mammography phantom

Page 18: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del
Page 19: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del
Page 20: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

TEST OPERACIONAL - CASSETTES RAYOS X Institución: Clinica del Country Fecha: Dic,2012 Equipo Modelo Sede Fabricante CR CAPSULA X CLINICA Fujifilm cassette 14x17 TAMAÑO (IP 35x43 cm) Fantoma mm =180 nominal medido ajuste mm 180 180 0 180 VALOR S para 1 mR 1 Sv = 100 mR exposición kVp 80 mA 100 mAs 2 dosis mR 1 1.014 FCR S Value Control Table 2 1.026 average 1.0324 3 1.057 4 1.038 5 1.027 Exponer IP 35x43 cm (leer monitor) S nominal 200 S min 154 S medido 279 S max 260 S corregido 200

Page 21: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

gamma is the relationship between the brightness of a pixel as it appears on the screen, and the numerical value of that pixel. You probably already know that a pixel can have any 'value' of Red, Green, and Blue between 0 and 255, and you would therefore think that a pixel value of 127 would appear as half of the maximum possible brightness, and that a value of 64 would represent one-quarter brightness, and so on. Well, that's just not the case,

Cathode-ray tubes, such as the screen you're probably reading this on at the moment, have a peculiar relationship between the voltage applied to them, and the amount of light emitted. It isn't linear, and in fact it follows what's called by mathematicians and other geeks, a 'power law' (a number raised to a power). The numerical value of that power is what we call the gamma of the monitor or system.

Page 22: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

DAC

Imagen Matriz

numeros

Señaleselectricas

monitor

Señaleselectricas

impresora

Page 23: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

DACSeñales

electricasMonitor curve

Señaleselectricas

Impresora curve

LUT

LUT

curve

curve

Procesador

Page 24: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del
Page 25: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Resultados de curvas Gamma para sistema radiografía digital tipo CR. La recta es la Compuesta ideal; la curva roja es la Compuesta medida.

Page 26: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del
Page 27: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

TEST OPERACIONAL

Institución : ONCOLOGICO

Fecha : 7/19/2012

Equipo Modelo

Fabricante

impresora DryPix   FUJIFILM

  8 x 10    

TAMAÑOnominal mm

medido mm diferencia

A 156.00 155.0 1%

B 202.00 201.0 0%

DENSIDADES REFERENCIA

referencia OD OD medida diferencia OD interno

0 0.20 0.19 5% 0.17

1 0.48 0.53 -10% 0.48

2 1.20 1.27 -6% 1.19

3 1.92 2.02 -5% 1.93

SMPTE FILM 17 steps

celda OD medida step OD OD medida diferencia

100% 0.23 92% 5 0.48 0.51 -6%

90% 0.53 82% 9 1.20 1.24 -3%

80% 0.82 71% 13 1.92 1.99 -4%

70% 1.10 62%

60% 1.38 52% RECTA

50% 1.67 42% origen 2.990

40% 1.97 31% pendiente -2.710

30% 2.26 21% R2 0.996

20% 2.49 13%

10% 2.70 6%

0% 2.87 0%

Page 28: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del
Page 29: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

CONCLUSIONES

• Tests Operacionales se ejecutan en 60 minutos y requieren dosímetro (Unfors) y fantomas (CIRS en mamografía y fantoma columna de densitómetro)

• Entregan información de Generador (kVp y mAs) y calidad de imagen

• Frecuencia cada 4 meses

Page 30: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

PROYECTO EN CURSOHISTOGRAMAS EN ECOGRAFIA

Page 31: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del
Page 32: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Performance Measurements:Dead ZoneHorizontal DistanceVertical DistanceDepth of PenetrationImage UniformityAxial ResolutionLateral ResolutionAnechoic Mass ResolutionGray Scale Contrast ResolutionElasticity Image Evaluation

Page 33: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del
Page 34: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del
Page 35: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Transductor convexo

Transductor OKCon postprocesamiento

Transductor OKSin postprocesamiento

Page 36: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del
Page 37: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Transductor OKSin postprocesamiento

Daño en cristalesSin postprocesamiento

Transductor convexo

Page 38: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del
Page 39: Tests Operacionales en Radiografíaciencias.bogota.unal.edu.co/fileadmin/content/gruposdeinvestigac... · Calor electrones Ampolla de vidrio Circuito de Alta tensión Circuito del

Transductor lineal

Sin postprocesamiento