Testo's measuring tips for sound level measurement

11

Click here to load reader

description

Whether it is for air conditioning or heating, disco noise, machine noise or noise in combustion systems, assessors, workplaces, testo db meters are the ideal solution!

Transcript of Testo's measuring tips for sound level measurement

Page 1: Testo's measuring tips for sound level measurement

Testo Sound Level MeasurementTesto Sound Level Measurement –

Measuring TipsMeasuring Tips

www.testo.in

Page 2: Testo's measuring tips for sound level measurement

New Sound Level Measuring Instruments testo 815 / 816New Sound Level Measuring Instruments testo 815 / 816

testo 815/816Applications 815Applications 816Basic ConceptBasic ConceptMeasuring Tips

2/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe

Page 3: Testo's measuring tips for sound level measurement

Application Areas testo 815Application Areas testo 815

testo 815

testo 815/816Applications 815Applications 816B i C t

Climate- and airconditioning i d t

Basic ConceptMeasuring Tips

industry

Use in trade enterprisesUse in trade enterprises

Measurements on office machineryMeasurements on office machinery

Measurement of machine noiseMeasurement of machine noise

Noise at combustion plants

3/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe

p

Page 4: Testo's measuring tips for sound level measurement

A li ti A 816Application Areas 816

testo 816

testo 815/816Applications 815Applications 816B i C t

workplace measurements

Basic ConceptMeasuring Tips

industrial noise

environmental noise

classification measurements

neighbouring claims

4/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe

Page 5: Testo's measuring tips for sound level measurement

Basic Concepts: Sound Evaluation GraphsBasic Concepts: Sound Evaluation Graphs

Pegel (dB)testo 815/816Applications 815Applications 816B i C t

The frequency range in which a sound level meter measures according to IEC 60651 ranges

Basic ConceptMeasuring Tips

Frequenz (Hz)

from31.5 Hz to 8000 Hz

The “ A” weighted graph corresponds to the hearing sensation of the human earof the human ear.

In this connection the technician speaks of “correct hearing volume”

The “C” weighted graph is used in case of many low

5/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe

The C weighted graph is used, in case of many low frequencies within the acoustic signal.

Page 6: Testo's measuring tips for sound level measurement

Basic Concepts: Time Evaluation “Fast” or “Slow ”

1/8 s 1/8 s 1/8 s

Signal

1/8 s 1/8 s 1/8 s 1/8 s 1/8 s

Fast:

testo 815/816Applications 815Applications 816Basic Concept Fast:

Long-term recording of the readings 1/8 s (125ms) and the value calculated therefrom is shown on the display

Basic ConceptMeasuring Tips

Zeit / TimeSi l

therefrom is shown on the display.

1 sSignal

Slow:

Recording of the readings in 1 s (1000ms)

and the value calculated therefrom is shown on the display.

The acoustic signal can be weighted timely “Slow ” (1000ms) or “Fast” (125ms) in order to meet the requirements of the sound source

Zeit / Time

6/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe

Fast (125ms), in order to meet the requirements of the sound source.

Page 7: Testo's measuring tips for sound level measurement

Basic Concepts: The Measuring Unit dB

Sound are tiny pressure variations of the ambient air.

Basic Concepts: The Measuring Unit dB

As the human ear holds an extremely large dynamic range, the specification of the pressure values would be unsuitable.

testo 815/816Applications 815Applications 816B i C t specification of the pressure values would be unsuitable.

Therefore a logarithmic presentation is preferred.

Basic ConceptMeasuring Tips

The derived parameter is a handy figure, the decibel = dB

The decibel is not an absolute measuring unit (as e. g. °C) but

a ratio. A measured value is put into ratio of a reference value (sound

Example:This equals how many dB?

reference value = 20 uPa).

meas. acoustic sound: 20.000 μPa Log10 (1000) = 3

20.000 μPa

20 μPa= 1000

7/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe

reference pressure level: 20 μPa 20 x 3 = 60dB

Page 8: Testo's measuring tips for sound level measurement

Basic Concepts: Acoustic Pressure / Sound LevelBasic Concepts: Acoustic Pressure / Sound Level

testo 815/816Applications 815Applications 816B i C t

jet

Basic ConceptMeasuring Tips

truck

air hammer

office

library

forest

The “measuring range” (dynamic complexity) of the human ear ranges from 0 dB to approx 140 dB

hearing limit

from 0 dB to approx. 140 dB

In order to protect the health of mankind, ear protection has to be

8/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe

used at a (permanent) sound level of >80 dB.

Page 9: Testo's measuring tips for sound level measurement

Basic Concepts: Accuracy Classes Standard DIN/IEC 60651Standard DIN/IEC 60651

testo 815/816Applications 815Applications 816B i C tBasic ConceptMeasuring Tips

The accuracy classes for sound level meter are internationally standardised in the standard DIN/IEC 60651

The operating temperature range is -10...+50°C. Instruments working in a range of 0...40 °C, receive a L as identification

Example: Class 2L

A sound level measuring instrument should be re-calibrated afterA sound level measuring instrument should be re-calibrated after translocation or temperature changes. For that purpose special sound calibrators are available

9/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe

testo 815 and testo 816 = Class 2 (+/-1.0 dB)

Page 10: Testo's measuring tips for sound level measurement

Handling / Measuring Tipsg g p

testo 815/816Applications 815Applications 816B i C tBasic ConceptMeasuring Tips

microphone alignment distance to body

According to DIN/IEC standard a sound level meter has to bepositioned in a zero degrees angle towards the sound source. That is,the microphone points directly into the direction of the sound source.

In order to prevent interferences due to sound reflections on the body,the measuring instrument should be held at least 30cm away from the

10/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe

g ybody of the measuring person.

Page 11: Testo's measuring tips for sound level measurement

Thank youF d t il l tFor more details log on to -www.testo.in

www thermalimager co inwww.thermalimager.co.in

www.fluegasanalyser.co.in

www measuringinstruments co inwww.measuringinstruments.co.in

F llFollow us on :