TESTING-CERTIFICAZIONE Fisica della Combustione TESTING ... ECO/Reaction to...

7
TESTING-CERTIFICAZIONE TESTING & CERTIFICATION Fisica della Combustione Physics of Combustion 1 7 0399\DC\REA\18_5 03/05/2018 Nome commerciale : K-Flex ECO Product Name Descrizione : Vedi pagina 2 Description : See page 2 Nome / Name : K-FLEX Polska Sp. Z.o.o. Indirizzo / Address : Wielenin-Kolonia 50B Città / City : 99-210 Uniejow - Poland Norma Tecnica / Technical standard: EN 13823:2010+A1:2014 - Reaction to fire tests for building products – Building products excluding floorings exposed to the thermal attack by a single burning item Originale cliente Original : Client Copia capo laboratorio Copy: Head of laboratory

Transcript of TESTING-CERTIFICAZIONE Fisica della Combustione TESTING ... ECO/Reaction to...

Page 1: TESTING-CERTIFICAZIONE Fisica della Combustione TESTING ... ECO/Reaction to Fire/Building/EUROPE... · TESTING-CERTIFICAZIONE TESTING & CERTIFICATION Fisica della Combustione Physics

TESTING-CERTIFICAZIONE TESTING & CERTIFICATION

Fisica della Combustione Physics of Combustion

1

7

0399\DC\REA\18_5

03/05/2018

Nome commerciale : K-Flex ECO Product Name

Descrizione : Vedi pagina 2 Description : See page 2

Nome / Name : K-FLEX Polska Sp. Z.o.o.

Indirizzo / Address : Wielenin-Kolonia 50B

Città / City : 99-210 Uniejow - Poland

Norma Tecnica / Technical standard: EN 13823:2010+A1:2014 - Reaction to fire tests for building products – Building products excluding floorings exposed to the thermal attack by a single burning item

Originale cliente Original : Client

Copia capo laboratorio Copy: Head of laboratory

Page 2: TESTING-CERTIFICAZIONE Fisica della Combustione TESTING ... ECO/Reaction to Fire/Building/EUROPE... · TESTING-CERTIFICAZIONE TESTING & CERTIFICATION Fisica della Combustione Physics

2 7

0399\DC\REA\18_5

03/05/2018

CSI organismo notificato 0497 CSI Notified body 0497

DATI GENERALI / GENERAL DATA:

• Data ricevimento campioni : Product supply date

01/03/2018

• Data esecuzione prove / Date of test : 02/05/2018

• Identificazione delle norme di riferimento : Standard reference identification

EN 13823:2010+A1:2014 EN 13238:2010

Identificazione dei metodi di prova : Test method identification

Orientativa Pre-test

Campionamento / Sampling : Provette di materiale fornite dal cliente. Specimens supplied by the client.

Condizionamento secondo EN 13238 : Conditioning compliing EN 13238

23 °C - 50 % u.r. per 336 ore 23 °C - 50 % r.h. for 336 hours

• Procedura normalizzata / Standard procedure : SI / YES

• Deviazione dai metodi di prova : Standard procedure deviation

SI(*) / YES(*)

• Controllo calcoli / Calculation check : SI / YES CAMPIONI ANALIZZATI / SAMPLES TESTED:

• 2 provette campione denominate / 2 specimens of sample identified:

K-Flex ECO Descrizione : Isolante elastomerico espanso Description : Elastomeric insulation foam

Spessore : 32 mm Thickness : 32 mm Densità : 55±5 kg/m3 Density : 55±5 kg/m3

Page 3: TESTING-CERTIFICAZIONE Fisica della Combustione TESTING ... ECO/Reaction to Fire/Building/EUROPE... · TESTING-CERTIFICAZIONE TESTING & CERTIFICATION Fisica della Combustione Physics

3 7

0399\DC\REA\18_5

03/05/2018

CSI organismo notificato 0497 CSI Notified body 0497

Tipo di substrato / Substrate type:

Lastra in acciaio come da EN 13238:2010. Steel sheet complying EN 13238:2010.

Allestimento del campione / Specimen mounting and fixing:

Costruzione del provino come da EN 15715:2009. Incollato sul supporto. Giunto verticale ed orizzontale standard. Specimen mounting complying to EN 15715:2009. Stitched on substrate. Standard vertical and horizontal joints.

DICHIARAZIONE / STATEMENTS:

• I risultati di prova contenuti nel presente rapporto si riferiscono esclusivamente al campione provato. Test results contained in this test report relate only to specimens tested.

• Il presente rapporto non può essere riprodotto parzialmente senza l’autorizzazione del Responsabile del

Centro. The test report shall not be reproduced except in full without the written approval of the Managing Director.

• I dati tecnici riportati nella descrizione del campione sono desunti dalla scheda tecnica allegata dal cliente al campione di prova. The technical data reported on the specimen description are taken from client technical sheet.

• I risultati di prova si riferiscono esclusivamente al comportamento dei provini di un materiale nelle particolari condizioni della prova; essi non sono destinati ad essere l’unico criterio per la valutazione della pericolosità potenziale del materiale in opera. The test results relate o the behaviour of the test specimens of a product under the particular conditions of the test; they are not intended to be the sole criterion for assessing the potential fire hazard of the product in use.

• (*) E’ stato provato un numero ridotto di provini. (*) A reduced number of specimens has been tested.

Page 4: TESTING-CERTIFICAZIONE Fisica della Combustione TESTING ... ECO/Reaction to Fire/Building/EUROPE... · TESTING-CERTIFICAZIONE TESTING & CERTIFICATION Fisica della Combustione Physics

4 7

0399\DC\REA\18_5

03/05/2018

CSI organismo notificato 0497 CSI Notified body 0497

FOTOGRAFIE / PHOTOGRAPHS:

Vista frontale ala lunga Long wing front view

Angolo verticale esterno dell’ala lunga Long wing vertical outer edge

Page 5: TESTING-CERTIFICAZIONE Fisica della Combustione TESTING ... ECO/Reaction to Fire/Building/EUROPE... · TESTING-CERTIFICAZIONE TESTING & CERTIFICATION Fisica della Combustione Physics

5 7

0399\DC\REA\18_5

03/05/2018

CSI organismo notificato 0497 CSI Notified body 0497

RISULTATI / RESULTS:

• Metodo di prova / Test method: EN 13823:2010+A1:2014

Identificazione provetta Specimen

identification

FIGRA 0.2MJ/0.4MJ

[W/s]

THR [MJ]

LFS [Si/Yes – No/No]

SMOGRA [m2/s2]

TSP [m2]

FDP [No/No -

<10s - >10s]

1

2499,8 a/at 339s 2499,8

a/at 339s

61,1 No/No 363,4 342,4 No/No

2

2441,6 a/at 339s 2441,6

a/at 339s

49,5 No/No 365,9 268,5 No/No

FIGRA = fire growth rate index

THR = total hest release

LFS = lateral flame spread

SMOGRA = smoke growth rate index

FDP = flaming droplets or particles

CLASSIFICAZIONE / CLASSIFICATION:

• Classificazione attribuita al campione: Sample classification:

potenzialmente / potentially E

DATA Date

Settore Fisica della Combustione Physics of Combustion Sector

B. U. Prodotto B. U. Product

03/05/2018

Lorenzo Zavaglio

Ing. P. Fumagalli

Documento firmato digitalmente ai sensi del D. Lgs. N. 82 del 7 Marzo 2005 e successive modifiche

Digitally signed document in accordance with Legislative Decree n. 82 dated March 7th 2005 and subsequent amendments.

Page 6: TESTING-CERTIFICAZIONE Fisica della Combustione TESTING ... ECO/Reaction to Fire/Building/EUROPE... · TESTING-CERTIFICAZIONE TESTING & CERTIFICATION Fisica della Combustione Physics

6 7

0399\DC\REA\18_5

03/05/2018

CSI organismo notificato 0497 CSI Notified body 0497

SBI Test Report Laboratory: CSI S.p.A.

Product: K-FLEX ECO

Test no. Test date: Print date:

1 02/05/2018 02/05/2018Test condition Check points Results

Baseline duct temp.(t=30-90) [K] 291.87 HRRav,burner [KW] 30.411 FIGRA threshold: 0.2 MJ [W/s] 2499.8Ambient pressure. [Pa] 100075 HRRstd burner [KW] 0.211 FIGRA threshold: 0.4 MJ [W/s] 2499.8Humidity [%] 75 CO2/O2 Ratioburner 0.578 THR600 [MJ] * 61.1

SPRav,burner [m²/s] 0.090 Lateral flame spread (LFS) reach the edge? Nokt 0.8600 SPRstd burner [m²/s] 0.009 SMOGRA [cm²/s²] 363.5kp 1.0800 TSP600 [m²] * 342.4E' [KJ/m³] 17200 Ambient temp. (t=30-90) [K] 288.99 Flaming droplets/particles (FDP) (flaming <= 10 s)? NoDuct diameter: [m] 0.315 No. of acceptable thermocouples 3 Flaming droplets/particles (FDP) (flaming > 10 s)? No

Minimum for flow [m³/s] 0.4642 Time to FIGRA0.2 [s] * 39Maximum for flow [m³/s] 0.6136 Time to FIGRA0.4 [s] * 39Burner response time [s] 6 Tig (2*6KW) [s] * 12

* After ignition of main burnerBaseline O2

a (t=30-90) [%] 20.6093 Synchronisation information Baseline Last point

Baseline O2 (t=30-90) [%] 20.9491 End data O2 [%] 20.9466 T-Duct (2.5 K drop from baseline) 315.10 303Baseline CO2 (t=30-90) [%] 0.0803 End data CO2 [%] 0.0793 O2 (0.05% rise from baseline) 20.6718 309Baseline light signal (t=30-90) 99.9717 End data light signal 99.7008 CO2 (0.02% drop from baseline) 0.2409 303

-500.0

0.0

500.0

1000.0

1500.0

2000.0

2500.0

3000.0

-50.0

0.0

50.0

100.0

150.0

200.0

210 260 310 360 410 460

FIGRA (W/s)kW or MJ

Time (s)

HRR, THR and FIGRA values (Zoom)

HRR-Prod.

HRR(30)

THR

FIGRA

-500

0

500

1000

1500

2000

2500

3000

-50.0

0.0

50.0

100.0

150.0

200.0

250.0

0 200 400 600 800 1000 1200 1400 1600

FIGRA (W/s)kW or MJ

Time (s)

HRR, THR and FIGRA values

HRR-Prod.

HRR(30)

THR

FIGRA

-50

0

50

100

150

200

250

300

350

400

450

-0.20

0.00

0.20

0.40

0.60

0.80

1.00

1.20

1.40

1.60

1.80

0 200 400 600 800 1000 1200 1400 1600

m2 or cm2/s2m2/s

Time (s)

SPR, TSP and SMOGRA values

SPR-Prod.

SPR(60)

TSP

SMOGRA

Page 7: TESTING-CERTIFICAZIONE Fisica della Combustione TESTING ... ECO/Reaction to Fire/Building/EUROPE... · TESTING-CERTIFICAZIONE TESTING & CERTIFICATION Fisica della Combustione Physics

7 7

0399\DC\REA\18_5

03/05/2018

CSI organismo notificato 0497 CSI Notified body 0497

SBI Test Report Laboratory: CSI S.p.A.

Product: K-FLEX ECO

Test no. Test date: Print date:

2 02/05/2018 02/05/2018Test condition Check points Results

Baseline duct temp.(t=30-90) [K] 291.97 HRRav,burner [KW] 30.084 FIGRA threshold: 0.2 MJ [W/s] 2441.6Ambient pressure. [Pa] 99955 HRRstd burner [KW] 0.368 FIGRA threshold: 0.4 MJ [W/s] 2441.6Humidity [%] 70 CO2/O2 Ratioburner 0.577 THR600 [MJ] * 49.5

SPRav,burner [m²/s] 0.068 Lateral flame spread (LFS) reach the edge? Nokt 0.8600 SPRstd burner [m²/s] 0.009 SMOGRA [cm²/s²] 365.9kp 1.0800 TSP600 [m²] * 268.5E' [KJ/m³] 17200 Ambient temp. (t=30-90) [K] 288.87 Flaming droplets/particles (FDP) (flaming <= 10 s)? NoDuct diameter: [m] 0.315 No. of acceptable thermocouples 3 Flaming droplets/particles (FDP) (flaming > 10 s)? No

Minimum for flow [m³/s] 0.4966 Time to FIGRA0.2 [s] * 39Maximum for flow [m³/s] 0.6094 Time to FIGRA0.4 [s] * 39Burner response time [s] 6 Tig (2*6KW) [s] * 12

* After ignition of main burnerBaseline O2

a (t=30-90) [%] 20.6339 Synchronisation information Baseline Last point

Baseline O2 (t=30-90) [%] 20.9534 End data O2 [%] 20.9417 T-Duct (2.5 K drop from baseline) 315.66 303Baseline CO2 (t=30-90) [%] 0.0796 End data CO2 [%] 0.0801 O2 (0.05% rise from baseline) 20.6765 309Baseline light signal (t=30-90) 100.1751 End data light signal 99.9579 CO2 (0.02% drop from baseline) 0.2398 300

-500.0

0.0

500.0

1000.0

1500.0

2000.0

2500.0

3000.0

-20.0

0.0

20.0

40.0

60.0

80.0

100.0

120.0

140.0

210 260 310 360 410 460

FIGRA (W/s)kW or MJ

Time (s)

HRR, THR and FIGRA values (Zoom)

HRR-Prod.

HRR(30)

THR

FIGRA

-500

0

500

1000

1500

2000

2500

3000

-20.0

0.0

20.0

40.0

60.0

80.0

100.0

120.0

140.0

160.0

0 200 400 600 800 1000 1200 1400 1600

FIGRA (W/s)kW or MJ

Time (s)

HRR, THR and FIGRA values

HRR-Prod.

HRR(30)

THR

FIGRA

-50

0

50

100

150

200

250

300

350

400

450

-0.20

0.00

0.20

0.40

0.60

0.80

1.00

1.20

1.40

1.60

0 200 400 600 800 1000 1200 1400 1600

m2 or cm2/s2m2/s

Time (s)

SPR, TSP and SMOGRA values

SPR-Prod.

SPR(60)

TSP

SMOGRA