TEST REPORT: 17static.benettongroup.com/wp-content/uploads/2018/... · TEST REPORT: 17.25986 dated...
Transcript of TEST REPORT: 17static.benettongroup.com/wp-content/uploads/2018/... · TEST REPORT: 17.25986 dated...
TEST REPORT: 17.25986
Page 1 of 2
*17.25986* 17.25986
This report is composed by 5 pages, of which: 2 pages for the summary 3 pages for the Report 17.25986a Date in sample: 26/5/2017 Issue date: 13/06/2017 APPLICANT OLIMPIAS GROUP SRL
LAB NO: (IT) 17.25986
Via delle Tezze 1 DATE IN: 26/05/2017 31050 Ponzano Veneto (TV) DATE OUT: 13/06/2017 PAGE: 2
Facility: OLIMPIAS GROUP SRL, c/o Viale dell’Industria, 37038 Soave (VR) Secondo prelievo
Sample Description:
INCOMING WATER Date and hour of sampling: May, 26th 2017 at 12:00 Sampling location: Well Water Sampling method: Single grab Sampling by: UL In-charge Technician Sampling Record N°: MICI2605201701
*17.25986*
17.25986
TEST REPORT: 17.25986 dated 13-05-2017
Page 2 of 2
TEST PERFORMED CONCLUSIONS
Metals //
Sulfide //
Sulfite //
Chemical Laboratory Supervisor Claudio Sironi
REMARKS 1. It is prohibited the partial reproduction, any changes or modifications of this test
report. The results are exclusively referred to the samples tested.
Issue date:29 May 2017201713 Jun 2017
Test beginning:
DATES APPLICANT
OLIMPIAS GROUP SRL
TEST REPORT: 17.25986a dated 13 June 2017
T F A RD
This section is an integral part of the TEST REPORT 17.25986
17.25986a
SulfideIdentification Parts
INCOMING WATER - OLIMPIAS GROUP SRL, c/o Viale dell’Industria, 37038 Soave (VR)SAMPLE DESCRIPTION (no. 354826)
Sulfide
Method: According to APAT CNR IRSA 4160 MAN 29 2003
Instrument: Laboratory equipment
Incoming water < 0,01
The results expressed are in mg/L.
The symbol < followed by a number indicates that the concentration of the substance is lower than the limit of
quantification (LOQ)
Legend:
Requirements:
Conclusion: See results.
Reference: Sulfide
Note:
page 1 of 3MD Standard Report CH_v5/14
SulfiteIdentification Parts
TEST REPORT: 17.25986a dated 13 Jun 2017
Sulfite
Method: According to APAT CNR IRSA 4150B MAN 29 2003
Instrument: Laboratory equipment
T F A RD
52029
Incoming water < 0,2
The results expressed are in mg/L.
The symbol < followed by a number indicates that the concentration of the substance is lower than the limit of
quantification (LOQ)
Legend:
Requirements:
Conclusion: See results.
Reference: Sulfite
Note:
page 2 of 3MD Standard Report CH_v5/14
Identification Parts
52024
TEST REPORT: 17.25986a dated 13 June 2017
Metals
Method: According to ISO17294-2 (2016) and ISO 11885 (2007)
Instrument: Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) and Inductively Coupled Plasma with Mass Detector (ICP-MS)
T F A RD
Compound
Pb
Cd
Hg
Sb
As
Co
Cu
Ni
Zn
Cr
Ag
< 0,01
< 0,01
< 0,001
< 0,01
< 0,005
< 0,01
< 0,25
< 0,05
0,54
< 0,05
< 0,005
Incoming water
The results are expressed in mg/L.
The symbol < followed by a number indicates that the concentration of the element is lower than the limit of
quantification (LOQ)
Legend:
MetalsRequirements:
Conclusion: See results.
Reference:
Note:
page 3 of 3MD Standard Report CH_v5/14 ••• END OF REPORT •••
TEST REPORT: 17.25987
Page 1 of 2
*17.25987* 17.25987
This report is composed by 20 pages, of which: 2 pages for the summary 18 pages for the Report 17.25987a Date in sample: 26/05/2017 Issue date: 13/06/2017 APPLICANT OLIMPIAS GROUP SRL
LAB NO: (IT) 17.25987
Via delle Tezze, 1 DATE IN: 26/05/2017 31050 Ponzano Veneto (TV) DATE OUT: 13/06/2017 PAGE: 2
Facility: OLIMPIAS GROUP SRL, c/o Viale dell’Industria, 37038 Soave (VR) Secondo prelievo
Sample Description:
RAW WASTEWATER Date and hour of sampling: May, 26th 2017 at 11:00 Sampling location: Homogenization Tank Sampling method: Single grab Sampling by: UL In-charge Technician Sampling Record N°: MICI2605201701
TEST REPORT: 17.25987 dated 13/06/2017
Page 2 of 2
TEST PERFORMED CONCLUSIONS
Alkylphenol and Alkylphenol ethoxylates (AP / APEOs) //
Chlorinated Benzenes and Toluenes //
Chlorophenols //
Azo-dyes //
Colourants - Carcinogenic //
Colourants – Disperse //
Flame Retardants //
Glycols //
Halogenated solvents //
Organotin compounds //
Perfluorinated compounds (PFCs) //
Phthalates //
Polycyclic aromatic hydrocarbons //
Organic Volatile compounds //
Metals //
Cr (VI) - Hexavalent Chromium //
Sulfide //
Sulfite //
Cyanide //
Chemical Laboratory Supervisor Claudio Sironi
REMARKS 1. It is prohibited the partial reproduction, any changes or modifications of this test
report. The results are exclusively referred to the samples tested.
Issue date:29 May 2017201713 Jun 2017
Test beginning:
DATES APPLICANT
OLIMPIAS GROUP SRL
TEST REPORT: 17.25987a dated 13 June 2017
T F A RD
This section is an integral part of the TEST REPORT 17.25987
17.25987a
Cr VIIdentification Parts
RAW WASTEWATER - OLIMPIAS GROUP SRL, c/o Viale dell’Industria, 37038 Soave (VR)SAMPLE DESCRIPTION (no. 354827)
Cr (VI) - Hexavalent Chromium
Method: According to USEPA 218.6
Instrument: Ion Cromatograph coupled with MS/UV detector
Raw wastewater < 0,001
The results expressed are in mg/L.
The symbol < followed by a number indicates that the concentration of the substance is lower than the limit of
quantification (LOQ)
Legend:
Requirements:
Conclusion: See results.
Reference: Chromium (VI) - Hexavalent Chromium
Note:
page 1 of 18MD Standard Report CH_v5/14
SulfideIdentification Parts
TEST REPORT: 17.25987a dated 13 Jun 2017
Sulfide
Method: According to APAT CNR IRSA 4160 MAN 29 2003
Instrument: Laboratory equipment
T F A RD
52028
Raw wastewater 1,2
The results expressed are in mg/L.
The symbol < followed by a number indicates that the concentration of the substance is lower than the limit of
quantification (LOQ)
Legend:
Requirements:
Conclusion: See results.
Reference: Sulfide
Note:
page 2 of 18MD Standard Report CH_v5/14
SulfiteIdentification Parts
TEST REPORT: 17.25987a dated 13 Jun 2017
Sulfite
Method: According to APAT CNR IRSA 4150B MAN 29 2003
Instrument: Laboratory equipment
T F A RD
52029
Raw wastewater 17,5
The results expressed are in mg/L.
The symbol < followed by a number indicates that the concentration of the substance is lower than the limit of
quantification (LOQ)
Legend:
Requirements:
Conclusion: See results.
Reference: Sulfite
Note:
page 3 of 18MD Standard Report CH_v5/14
CyanideIdentification Parts
TEST REPORT: 17.25987a dated 13 Jun 2017
Cyanide
Method: According to APAT CNR IRSA 4070 MAN 29 2003
Instrument: UV-Visible Spectrophotometer
T F A RD
52040
Raw wastewater < 0,05
The results expressed are in mg/L.
The symbol < followed by a number indicates that the concentration of the substance is less than the limit of
quantification (LOQ)
Legend:
Requirements:
Conclusion: See results.
Reference: Cyanide
Note:
page 4 of 18MD Standard Report CH_v5/14
Identification Parts Result
52000
TEST REPORT: 17.25987a dated 13 June 2017
Chlorobenzenes and Chlorotoluenes
Method: According to USEPA 8260B, 8270D
Instrument: Gaschromatograph with Mass detector
T F A RD
Monochlorobenzene1,2-dichlorobenzene1,3-dichlorobenzene1,4-dichlorobenzene1,2,3-trichlorobenzene1,2,4-trichlorobenzene1,3,5-trichlorobenzene1,2,3,4-tetrachlorobenzene1,2,3,5-tetrachlorobenzene1,2,4,5-tetrachlorobenzenePentachlorobenzeneHexachlorobenzene2-chlorotoluene3-chlorotoluene4-chlorotoluene2,3-dichlorotoluene2,4-dichlorotoluene2,5-dichlorotoluene2,6-dichlorotoluene3,4-dichlorotoluene3,5-dichlorotoluene2,3,4-trichlorotoluene2,3,6-trichlorotoluene2,4,5-trichlorotoluene2,4,6-trichlorotoluene3,4,5-trichlorotoluene2,3,4,5-tetrachlorotoluene2,3,5,6-tetrachlorotoluene2,3,4,6-tetrachlorotoluenePentachlorotoluene
108-90-795-50-1541-73-1106-46-787-61-6120-82-1108-70-3634-66-2634-90-295-94-3608-93-5118-74-195-49-8108-41-8106-43-432768-54-095-73-819398-61-9118-69-495-75-025186-47-47359-72-02077-46-56639-30-123749-65-721472-86-676057-12-029733-70-8875-40-1877-11-2
< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2< 0,2
Raw wastewater
The results expressed are in µg/L.The symbol < followed by a number indicates that the concentration of the substance is lower than the limit ofquantification (LOQ)
Legend:
Chlorobenzenes and ChlorotoluenesRequirements:
Conclusion: See results.Reference:
Note:
page 5 of 18MD Standard Report CH_v5/14
Identification Parts Results
52001
TEST REPORT: 17.25987a dated 13 June 2017
Chlorophenols
Method: According to USEPA 8270D
Instrument: Gas Chromatograph with Mass Detector (MS)
T F A RD
2-Chlorophenol3-Chlorophenol4-Chlorophenol2,3-Dichlorophenol2,4-Dichlorophenol2,5-Dichlorophenol2,6-Dichlorophenol3,4-Dichlorophenol3,5-Dichlorophenol2,3,4-Trichlorophenol2,3,5-Trichlorophenol2,3,6-Trichlorophenol2,4,5-Trichlorophenol2,4,6-Trichlorophenol3,4,5-Trichlorophenol2,3,4,5-Tetrachlorophenol2,3,4,6-Tetrachlorophenol2,3,5,6-TetrachlorophenolPentachlorophenol
95-57-8108-43-0106-48-9576-24-9120-83-2583-78-887-65-095-77-2591-35-515950-66-0933-78-8933-75-595-95-488-06-2609-19-84901-51-358-90-2935-95-587-86-5
< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5< 0,5
Raw wastewater
The results expressed are in µg/L.The symbol < followed by a number indicates that the concentration of the element is lower than the limit ofquantification (LOQ)
Legend:
ChlorophenolsRequirements:
Conclusion: See results.Reference:
Note:
page 6 of 18MD Standard Report CH_v5/14
Identification Parts
52002
TEST REPORT: 17.25987a dated 13 June 2017
Dyes - Azo
Method: According to EN 14362-1 , EN 14362-3
Instrument: Liquid chromatograph with Mass selective detector (HPLC -MS); Gas chromatograph with Mas selective detector (GC -MS).
T F A RD
4,4’-methylene-bis-(2-chloro-aniline)4,4’-methylenedianiline4,4’-oxydianiline4-chloroaniline3,3’-dimethoxylbenzidine3,3’-dimethylbenzidine6-methoxy-m-toluidine2,4,5-trimethylaniline4,4’-thiodianiline4-aminoazobenzene4-methoxy-m-phenylenediamine4,4’-methylene-di-o-toluidine2,6-xylidineo-anisidine2-naphthylamine3,3’-dichlorobenzidine4-aminodiphenylBenzidineo-toluidine2,4-xylidine4-chloro-o-toluidine4-methyl-m-phenylenediamineo-aminoazotoluene5-nitro-o-toluidine
101-14-4101-77-9101-80-4106-47-8119-90-4119-93-7120-71-8137-17-7139-65-160-09-3615-05-4838-88-087-62-790-04-091-59-891-94-192-67-192-87-595-53-495-68-195-69-295-80-797-56-399-55-8
< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1< 0,1
Raw wastewater
The results expressed are in µg/L.The symbol < followed by a number indicates that the concentration for every Aromatic Amines detected (See listbelow) is lower than the limit of quantification (LOQ).
Legend:
Dyes - AzoRequirements:
Conclusion: See results.Reference:
Note:
page 7 of 18MD Standard Report CH_v5/14
Identification Parts
52003
TEST REPORT: 17.25987a dated 13 June 2017
Alkylphenol and Alkylphenol Ethoxylates
Method: According to ISO 18857-2 and ISO 18254-1
Instrument: H.P.L.C.with DAD/MSD detectors and Gaschromatograph with mass detector (GC-MS)
T F A RD
Nonylphenol (NP)
Octylphenol (OP)
Octylphenol ethoxylates, (OPEO)
Nonylphenol ethoxylates(NPEO)
104-40-511066-49-225154-52-384852-15-3140-66-91806-26-427193-28-89002-93-19036-19-568987-90-69016-45-926027-38-337205-87-168412-54-4127087-87-0
< 5
< 5
< 5
< 5
Raw wastewater
The results expressed are in µg/L.The symbol < followed by a number indicates that the concentration of the element is lower than the limit ofquantification (LOQ)
Legend:
Alkylohenol and Alkylphenol EthoxylatesRequirements:
Conclusion: See results.Reference:
Note:
page 8 of 18MD Standard Report CH_v5/14
Identification Parts Result
52004
TEST REPORT: 17.25987a dated 13 June 2017
Dyes Carcinogenic and Disperse
Method: According to DIN 54231
Instrument: Liquid cromatograph with DAD and MS detector
T F A RD
Compound
Disperse DyesCarcinogenic Dyes
< 50< 500
Raw wastewater
The results expressed are in µg/L.The symbol < followed by a number indicates that the concentration of the substance is lower than the limit ofquantification (LOQ)
Legend:
Dyes - Carcinogenic and DisperseRequirements:
Conclusion: See results.Reference:
List of Disperse Dyes detected (Which are classified to be allergenic) - CAS Number––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––1 Disperse Yellow 1 119-15-3 11 Disperse Red 17 3179-89-32 Disperse Blue 102 12222-97-8 12 Disperse Blue 7 3179-90-63 Dipserse Blue 106 12223-01-7 13 Disperse Blue 26 3860-63-74 Disperse Yellow 39 12236-29-2 14 Disperse Yellow 49 54824-37-25 Disperse Orange 37/76/59 13301-61-6 15 Disperse Blue 35 12222-75-26 Disperse Brown 1 23355-64-8 16 Disperse Blue 124 61951-51-77 Disperse Orange 1 2581-69-3 17 Disperse Yellow 9 6373-73-58 Disperse Yellow 3 2832-40-8 18 Disperse Orange 3 730-40-59 Disperse Red 11 2872-48-2 19 Disperse Blue 35 56524-77-710 Disperse Red 1 2872-52-8
List of Dyes detected (Which are classified to be carcinogenic) - CAS Number–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––1 Acid Red 26 3761-53-3 9 Disperse Blue 3 2475-46-92 Basic Red 9 569-61-9 10 Basic Blue 26 2580-56-53 Basic Violet 14 632-99-5 11 Basic Green 4 569-64-2/2437-29-8/10309-95-24 Direct Black 38 1937-37-75 Direct Blue 6 2602-46-26 Direct Red 28 573-58-07 Disperse Blue 1 2475-45-88 Disperse Orange 11 82-28-0
Note:
page 9 of 18MD Standard Report CH_v5/14
Identification Parts Results
52005
TEST REPORT: 17.25987a dated 13 June 2017
Flame Retardants
Method: According to USEPA 8270
Instrument: Gaschromatograph with mass detector (GC-MS)
T F A RD
Compound
TCEPdecaBDETRISpentaBDEoctaBDEBISTEPAPBBTBBPAHBCDDBBMPTDCPSCCP
115-96-81163-19-5126-72-732534-81-932536-52-05412-25-9545-55-159536-65-179-94-73194-55-63296-90-013674-87-885535-84-8
< 5< 5< 5< 5< 5< 5< 5< 5< 5< 5< 5< 5< 5
Raw wastewater
The results expressed are in µg/L.The symbol < followed by a number indicates that the concentration of the element is lower than the limit ofquantification (LOQ)The substances determined are:TCEP : Tris(2-chloroethyl)phosphate; - DecaBDE : Decabromodiphenyl ether; - TRIS : Tris(2,3-dibromopropyl)-phosphate; - PentaBDE : Pentabromodiphenyl ether; - OctaBDE : Octabromodiphenyl ether; - BIS : Bis(2,3-dibromopropyl)phosphate; - TEPA : Tris(1-aziridinyl)phosphine oxide; - PBB : Polybromobiphenyls; - TBBPA :Tetrabromobisphenol A; - HBCDD : Hexabromocyclododecane; - BBMP : 2,2-bis(bromomethyl)-1,3-propanediol ; -TDCP : Tris(1,3-dichloro-isopropyl)phosphate ; - SCCP : Short-chain chlorinated paraffins
Legend:
Flame RetardantsRequirements:
Conclusion: See results.Reference:
Note:
page 10 of 18MD Standard Report CH_v5/14
Identification Parts
52006
TEST REPORT: 17.25987a dated 13 June 2017
Glycols
Method: According to USEPA 8270
Instrument: Gaschromatograph with Mass Detector
T F A RD
Bis(2-methoxyethyl)-ether2-ethoxyethanol2-ethoxyethyl acetateEthylene glycol dimethyl ether2-methoxyethanol2-methoxyethylacetate2-methoxypropylacetateTriethylene glycol dimethyl ether
111-96-6110-80-5111-15-9110-71-4109-86-4110-49-670657-70-4112-49-2
< 50< 50< 50< 50< 50< 50< 50< 50
Raw wastewater
The results expressed are in µg/L.The symbol < followed by a number indicates that the concentration of the element is lower than the limit ofquantification (LOQ)
Legend:
GlycolsRequirements:
Conclusion: See results.Reference:
Note:
page 11 of 18MD Standard Report CH_v5/14
Identification Parts
52007
TEST REPORT: 17.25987a dated 13 June 2017
Halogenated Solvents
Method: According to USEPA 8260B
Instrument: Gaschromatograph with FID and Mass Detector
T F A RD
1,2-DichloroethaneMethylene chlorideTrichloroethyleneTetrachloroethylene
107-06-275-09-279-01-6127-18-4
< 1< 1< 1< 1
Raw wastewater
The results expressed are in µg/L.The symbol < followed by a number indicates that the concentration of the element is lower than the limit ofquantification (LOQ)
Legend:
Halogenated SolventsRequirements:
Conclusion: See results.Reference:
Note:
page 12 of 18MD Standard Report CH_v5/14
Identification Parts Results
52008
TEST REPORT: 17.25987a dated 13 June 2017
Organotin Compounds
Method: According to ISO 17353
Instrument: Gas - Chromatograph with Mass Detector (GC-MSD)
T F A RD
METDMTTMTMBTDBTTBTMPTDPTTPTMOTDOTTOT
MultipleMultipleMultipleMultipleMultipleMultipleMultipleMultipleMultipleMultipleMultipleMultiple
< 0,01< 0,01< 0,01< 0,01< 0,01< 0,01< 0,01< 0,01< 0,01< 0,01< 0,01< 0,01
Raw wastewater
The results expressed are in µg/L.The symbol < followed by a number indicates that the concentration of the element is lower than the limit ofquantification (LOQ)MET : Monomethyltin; - DMT: Dimethyltin; - TMT : Trimethyltin; MBT : Monobutyltin; - DBT : Dibutyltin; - TBT :Tributyltin; - MPT : Monophenyltin; - DPT : Diphenyltin; - TPT : Triphenyltin; - MOT : Monooctyltin; - DOT : Dioctyltin; -TOT : Trioctyltin.
Legend:
Organotin CompoundsRequirements:
Conclusion: See results.Reference:
Note:
page 13 of 18MD Standard Report CH_v5/14
Identification Parts
52009
TEST REPORT: 17.25987a dated 13 June 2017
Perfluorinated and Polyfluorinated Chemicals (PFCs)
Method: According to DIN 38407-42
Instrument: Liquid Chromatograph with Mass detector and Gas Chromatography with mass detector
T F A RD
PFOS
PFOAPFBS
PFHxA8:2 FTOH6:2 FTOH
355-46-4432-50-7335-67-129420-49-329420-43-3307-24-4678-39-7647-42-7
< 0,01
< 0,01< 0,01
< 0,01< 1< 1
Raw wastewater
The results expressed are in µg/L.The symbol < followed by a number indicates that the concentration of the element is lower than the limit ofquantification (LOQ)
Legend:
Perfluorinated and Polyfluorinated Chemicals (PFCs)Requirements:
Conclusion: See results.Reference:
Note:
page 14 of 18MD Standard Report CH_v5/14
Identification Parts
52010
TEST REPORT: 17.25987a dated 13 June 2017
Phthalates
Method: According to USEPA 8270D
Instrument: Gascromatograph with Mass Detector - Liquid Cromatograph with DAD and Mass detector
T F A RD
DEHPBBPDBPDEPDNOPDINPDIDPDIBPDnHPDMEPDPRPDIOPDCHPDNPDHNUPDIHP
117-81-785-68-784-74-284-66-2117-84-028553-12-026761-40-084-69-584-75-3117-82-8131-16-827554-26-384-61-784-76-468515-42-471888-89-6
< 10< 10< 10< 10< 10< 10< 10< 10< 10< 10< 10< 10< 10< 10< 10< 10
Raw wastewater
The results are expressed in µg/L.The symbol < followed by a number indicates that the concentration of the analyte is lower than the limit ofquantification (LOQ)
The phthalates determined are:DEHP : Bis (2-ethylhexyl) phthalate ; - BBP : Butyl benzyl phthalate ; - DBP : Di-n-butyl phthalate ; - DEP : Diethylphthalate; - DNOP : Di-n-octyl phthalate; - DINP : Di-isononyl phthalate; - DIDP : Di-iso-decyl phthalate ; - DIBP : Di-isobutyl phthalate ; - DnHP : Di-n-hexyl phthalate; - DMEP : Dimethoxyethyl phthalate; - DPRP : Di-n-propyl phthalate;- DIOP : Di-iso-octyl phthalate; - DCHP : Di-cyclohexyl phthalate; - DNP : Dinonyl phthalate; - DIHP : Di-isoheptylphthalate; - DHNUP : 1,2-Benzene-di-carboxylic acid, di-C7-11-branched and linear alkyl esters.
Legend:
PhthalatesRequirements:
Conclusion: See results.Reference:
Note:
page 15 of 18MD Standard Report CH_v5/14
Identification Parts Results
52011
TEST REPORT: 17.25987a dated 13 June 2017
Polycyclic Aromatic Hydrocarbons (PAH)
Method: According to USEPA 8270
Instrument: Gascromatograph with Mass Detector
T F A RD
Compound
Benzo(a)pyreneBenzo(e)pyreneBenzo(a)anthraceneBenzo(b)fluorantheneBenzo(j)fluorantheneBenzo(k)fluorantheneChryseneDibenzo(a,h)anthracene
AcenaphteneAcenaphthyleneAnthraceneBenzo(g,h,i)peryleneFluorantheneFluoreneIndeno(1,2,3-cd)pyreneNaphthalenePhenanthrenePyrene
50-32-8192-97-256-55-3205-99-2205-82-3207-08-9218-01-953-70-3
83-32-9208-96-8120-12-7191-24-2206-44-086-73-7193-39-591-20-385-01-8129-00-0
< 1< 1< 1< 1< 1< 1< 1< 1
< 1< 1< 1< 1< 1< 1< 1< 1< 1< 1
Raw wastewater
The results are expressed in µg/L.The symbol < followed by a number inicates that the concentration of the element is lower than the limit ofquantification (LOQ)
Legend:
Polycyclic Aromatic Hydrocarbons (PAH)Requirements:
Conclusion: See results.Reference:
Note:
page 16 of 18MD Standard Report CH_v5/14
Identification Parts
52012
TEST REPORT: 17.25987a dated 13 June 2017
Volatile Organic Compounds
Method: According to ISO 11423-1
Instrument: GC-MS headspace
T F A RD
BenzeneXyleneo-cresolp-cresolm-cresol
71-43-21330-20-795-48-7106-44-5108-39-4
< 1< 1< 1< 1< 1
Raw wastewater
The results are expressed in µg/L.The symbol < followed by a number indicates that the concentration of the substances is lower than the limit ofquantification (LOQ)
Legend:
Volatile Organic Compounds (VOC)Requirements:
Conclusion: See results.Reference:
Note:
page 17 of 18MD Standard Report CH_v5/14
Identification Parts
52024
TEST REPORT: 17.25987a dated 13 June 2017
Metals
Method: According to ISO17294-2 (2016) and ISO 11885 (2007)
Instrument: Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) and Inductively Coupled Plasma with Mass Detector (ICP-MS)
T F A RD
Compound
PbCdHgSbAsCoCuNiZnCrAg
< 0,01< 0,01
< 0,001< 0,01
< 0,005< 0,01
1,45< 0,05
1,05< 0,05
< 0,005
Raw wastewater
The results are expressed in mg/L.The symbol < followed by a number indicates that the concentration of the element is lower than the limit ofquantification (LOQ)
Legend:
MetalsRequirements:
Conclusion: See results.Reference:
Note:
page 18 of 18MD Standard Report CH_v5/14 ••• END OF REPORT •••
TEST REPORT: 17.25988
Page 1 of 2
*17.25988* 17.25988
This report is composed by 5 pages, of which: 2 pages for the summary 3 pages for the Report 17.25988a Date in sample: 26/5/2017 Issue date: 13/06/2017 APPLICANT OLIMPIAS GROUP SRL
LAB NO: (IT) 17.25988
Via delle Tezze 1 DATE IN: 26/05/2017 31050 Ponzano Veneto (TV) DATE OUT: 13/06/2017 PAGE: 2
Facility: OLIMPIAS GROUP SRL, c/o Viale dell’Industria, 37038 Soave (VR) Secondo prelievo
Sample Description:
TREATED WATER Date and hour of sampling: May, 26th 2017 from 9:30 to 14:30 Sampling location: Clarifying Well (Purifier Exit) Sampling method: Composite Sample Sampling by: UL In-charge Technician Sampling Record N°: MICI2605201701
*17.25988*
17.25988
TEST REPORT: 17.25988 dated 13-06-2017
Page 2 of 2
TEST PERFORMED CONCLUSIONS
Metals //
Sulfide //
Sulfite //
Chemical Laboratory Supervisor Claudio Sironi
REMARKS 1. It is prohibited the partial reproduction, any changes or modifications of this test
report. The results are exclusively referred to the samples tested.
Issue date:29 May 2017201713 Jun 2017
Test beginning:
DATES APPLICANT
OLIMPIAS GROUP SRL
TEST REPORT: 17.25988a dated 13 June 2017
T F A RD
This section is an integral part of the TEST REPORT 17.25988
17.25988a
SulfideIdentification Parts
TREATED WATER - OLIMPIAS GROUP SRL, c/o Viale dell’Industria, 37038 Soave (VR)
SAMPLE DESCRIPTION (no. 354829)
Sulfide
Method: According to APAT CNR IRSA 4160 MAN 29 2003
Instrument: Laboratory equipment
Treated water 0,03
The results expressed are in mg/L.
The symbol < followed by a number indicates that the concentration of the substance is lower than the limit of
quantification (LOQ)
Legend:
Requirements:
Conclusion: See results.
Reference: Sulfide
Note:
page 1 of 3MD Standard Report CH_v5/14
SulfiteIdentification Parts
TEST REPORT: 17.25988a dated 13 Jun 2017
Sulfite
Method: According to APAT CNR IRSA 4150B MAN 29 2003
Instrument: Laboratory equipment
T F A RD
52029
Treated water < 0,2
The results expressed are in mg/L.
The symbol < followed by a number indicates that the concentration of the substance is lower than the limit of
quantification (LOQ)
Legend:
Requirements:
Conclusion: See results.
Reference: Sulfite
Note:
page 2 of 3MD Standard Report CH_v5/14
Identification Parts
52024
TEST REPORT: 17.25988a dated 13 June 2017
Metals
Method: According to ISO17294-2 (2016) and ISO 11885 (2007)
Instrument: Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) and Inductively Coupled Plasma with Mass Detector (ICP-MS)
T F A RD
Compound
Pb
Cd
Hg
Sb
As
Co
Cu
Ni
Zn
Cr
Ag
< 0,01
< 0,01
< 0,001
< 0,01
< 0,005
< 0,01
< 0,25
< 0,05
1,52
< 0,05
< 0,005
Treated water
The results are expressed in mg/L.
The symbol < followed by a number indicates that the concentration of the element is lower than the limit of
quantification (LOQ)
Legend:
MetalsRequirements:
Conclusion: See results.
Reference:
Note:
page 3 of 3MD Standard Report CH_v5/14 ••• END OF REPORT •••