Test Report Spacers cast concrete test certificate...according to DIN CEN / TS 12390-9 via CDF test...

15
Max Frank GmbH & Co. KG Mitterweg 1 | 94339 Leiblfing | Germany | Phone +49 9427 189-0 | Fax +49 9427 1588 | [email protected] 105PZ01/01-INTGB-12/15 www.maxfrank.com Test Report Spacers cast concrete M 0190 / 2015 | 31.04.2015 | english Determination of the water penetration on concrete specimens with built-in spacers according to DIN 1048, Part 5 freeze-thaw test according to DIN CEN / TS 12390-9 via CDF test methods. Examination after thermal cycling Tested by: Kiwa, Garching

Transcript of Test Report Spacers cast concrete test certificate...according to DIN CEN / TS 12390-9 via CDF test...

  • Max Frank GmbH & Co. KG

    Mitterweg 1 | 94339 Leiblfing | Germany | Phone +49 9427 189-0 | Fax +49 9427 1588 | [email protected]

    105PZ01/01-INTGB-12/15 www.maxfrank.com

    Test Report Spacers cast concrete M 0190 / 2015 | 31.04.2015 | english

    Determination of the water penetration on concrete specimens with

    built-in spacers according to DIN 1048, Part 5 freeze-thaw test

    according to DIN CEN / TS 12390-9 via CDF test methods.

    Examination after thermal cycling

    Tested by: Kiwa, Garching

  • l¡iwa

    I

    I

    Client

    Max Frank GmbH & Co. KGMitterweg 194339 Leiblfing

    Order date

    Test material

    Project

    Testing period

    Tested by

    Test period

    Garching, 31 . August 2054malmz

    p.p

    Partner for progress

    Test reportOrd€r.no.

    M 0190 I 2015Page 1 I 14

    01.July 2015

    Single Spacer with plastic holder AB 50 HVF

    Determination of the water penetration onconcrete specimens with built-in spacersaccording to DIN 1048, Part 5 freeze-thaw testaccording to DIN CEN / TS 12390-9 via CDF testmethods.Examination after thermal cycling

    07. July - 28. August 2015

    Kiwa GmbH, NL München

    July 2015 - August 2015

    p.p.

    o

    Dipl.-lng. (FH)Andreas Peter MaierMatzngf - person respensible -

    . Team Leader -The test report contalns 1 5 pagrs.The legt results roleto to tht pr€senl€d to semple m8teriale. The eample materlals ls consumend,A pertlál dupllcation or disclosur€ of the t€el report le permltted only wlth our wrltten permlsslon,,Oplnions end int6rpr€tElions of the lnepectlon are ldentlfled ln accordencc wlth olN EN ISO /lEC 17 025, point 5.10.5 itâlics.

    Klw¡ GmbHGutonborg8treßs 25E5748 GarchlngTel. 089 329880-0, Fex 329880.40

    105PZ01/01-INTGB-12/15

  • ldwa

    Contents

    I

    2

    2.1

    2,2

    2.3

    3

    3.1

    3.2

    3.2.1

    3.2.2

    3.3

    4

    appendlx:r Photos

    Progress

    M 0190 I 2015Page 2 I 14

    Examination water penetratlon

    Freeze-thaw testing according CDF method

    Testing with thermal cycling

    Examination water penetration

    Freeze-thaw testing accordlng CDF method

    Fluid intake by capillary suction

    .3

    .4

    5

    5

    6

    7

    7

    7

    7

    ITotal amount of scaled material by the frost-thaw stress......................8

    Temperatur cycling ...............9Summary

  • klwaPKrgrert

    M 0190 I 2016Page 3 I 14

    I General

    Klwa GmbH wae contracted by Max Frank GmbH, represented by

    Mr. Oetermeler and Mr. Lindner, detemine the concrete samples wlth bullt lnspecers AB 50 HVF to water penetration, the freeze-thaw testlng accodlng tothe CDF-method and the determine test afterthermal cycllng.

    To thlE end the specem werc delivered on June dellvered by Mr. OstermElEr.

    All eampllngs and testlngs where performed by employee of our laboratorles lnGarchlng

  • I

    I

    lriwaPartner frlr progress

    M 0190 I 2015Page 4 I 14

    2 Test methodology

    The preparation of the concrete specimen (cube with an edge length of 20 and15 cm) was performed at 7. July 2015, according to the following concreteformula:

    Concrete strength class C 30/37 (0/16 mm, F3)

    - Cement CEM ll/A-LL 42,5- Number of varities: 15342100- Exposure classes: XD1 , XF2

    In the center cube samples 1 each spacer was set in concreted

    The storage of the samples was carried out ( in the forms covered with foil) for24 hours at about 20 ' C. After removal of the forms a circular area withdiameter fo about 10 cm at the center area of the testing side with the waterpressure was roughenect.

    The storage of specimens for the freeze{haw testing according to the CDFprocess and testing of the thermal cycling was carried out according to thestandard.

  • I¡iwa

    t

    Partncr I ProSress

    M 0190 I 2015Page 5 I 14

    2.1 Examination water penetration

    The test was carried out according to DIN 1048-5, whereby the specimenswere opplied 5 bar water pressure for 72 hours at the side of the spacer.Subsequently the test specimens were split in the direction of sample heightand the depth of water was measured on the cross section of the cleavedsample.

    2.2 Freez-thaw test accordlng to GDF method

    The determination ol freeze-ldeicing salt resistance with di-icing salts solutionwas performed according to DIN CEN / TS 12390-9 with CDF method(alternative method) at the surface of the concrete cube with spacers.

    This test method determines the weathering amount of surfaces defined by anumber of freeze-thaw cycles in the presence of a de-icing agent solution. Asa de-icing agent solution a3o/o sodium chloride solution was used.

    Three days before the start of the pre-saturation with the test solution a lateralseal with aluminum foil with butyl rubber was applied. There after thespecimens were stored (seven days in the test solution) for capillary fluidacquisition seven days in the test solution.

    Before starting the freeze / thaw cycles loosely adhering particles wereremoved from the test surface of the specimens by treatment in an ultrasonicbath.

    It was followed by a stress on the specimen with 28 freeze / thaw cycles. Theduration of one freeze-thaw cycle tock 12 hours. The temperature variationcorresponded to the requirements of DIN CEN / TS 12390-9, Figure 10(temperatures between t 20 " C.)

    t

  • kiwa

    I

    I

    Partner progre6s

    M 0190 I 2015Page 6 I 14

    To determine the surface scaling loose components of the test areas wasremoved after every 6, 10, 14 and 28lreeze / thaw cycles by an ultrasonicbath. The weathered material was collected and filtered. After drying at 105 "C to constant mass, the mass of scaling was determined and related to theparticular test plots.

    2.3 Testing with termal cycling

    The test specimen with the cast spacers were subjected to a ten-time thermalcycling at temperatures between + 60' C and -10' C.Therefore the dice suúaces were heated by radiant heat for about I hours at atemperature of + 60 " C. Subsequently the cubes were stored for about 16hours in a freezer at a temperature of -10 " C.After ten temperature changes the concrete surfaces were visually inspectedand photographed.

    Test period: 05. August to 28. August 2015

    t

  • l¡iwa

    I

    3

    3.1

    3.2 Total amount of scaled material by the frost.thaw stress3.2.1 Fluid absorption by capillary suction

    = average, SA =

    Irartner for progress

    M 0190 I 2015Page 7 I 14

    Test resultsExamlnatlon water penetration

    After cleavage, it was found that the samples have an average waterpenetration of about 0,3 cm. The maximum allowed penetration depth of 5 cmwas not exceeded.

    ¡

    TestNr.

    Mass of solution absorbed in M .-% after

    3 days 5 days 6 days 7 days

    1 0,36 0,38 0,39 0,39

    2 0,36 0,43 0,44 0,44

    3 0,52 0,57 0,57 0,58

    MW 0,41 0,46 0,47 0,47

    SA 0,09 0,10 0,09 0,44

  • kiwaPartner ProSrens

    M 0190 I 2015Page 8 I 14

    Fluld absorptlon by capillary suction

    I 0,500,45

    0,40

    0,35

    0,30

    0,25

    0,20

    0,15

    0,10

    0,05

    0,00

    Beginning of the freeze-thaw cycles:

    The end of the freeze-thaw cycles:

    s¡..

    0 1 2

    Day

    I 3.2,2 Total amount of scaled material by the frosþthaw stress

    43 5 6 7

    14. August 2015

    28, August 201 5

    ,/,/

    ./

    TestNr

    Test areaIm']

    Total mass of the dried scaled material related according tothe test area in ko/m2

    6 Zyklen 10 Zyklen 14 Zyklen 28 Zyklen

    1 0,225 0,113 0,208 0,313 1,465

    2 0,0225 0,071 0,149 0,213 1,728

    3 0,0225 0,064 0,151 0,232 0,869

    MW 0,083 0,169 0,253 1,354

    SA 0,03 0,03 0,05 0,44

    I

    MW = av€rage, SA = Blandard deviation

  • kiwa

    t

    Protres.e

    M 0190 I 2015Page I I 14

    Weatherlng by freeze-thaw stress

    1,600

    1,400

    1,200

    1,000

    H o,Boo!0,600

    0,400

    0,200

    0,0000 2 4 6 I 10 12 14 16 18 20 22 24 26 28

    Number of freeze-thaw cyclec

    3.3 Temperatur cycling

    After ten thermal shocks no cracks or cracks or spallings at the vicinity of theindirect un-cast spacers of the concrete surfaces were detected (see photos).

    4 SummeryAn audited spacers AB 50 HVF no discernible damage ( spalling, cracksor the like ) could be observed

    Garching, 31. August 2015

    ån¡¡hmel(dþdqrîi m¡f,|m¡h Abtltroru¡g J,!

  • l¡iwaPârtner for progress

    M 0190 I 2015Page 10 I 14

    ;

    Picture 1: Spacer used

    :

    T

    Picture 2: Dice formwork with integrated spacer

  • I¡lwa

    t

    progress

    M 0190 I 2015Page 11 I 14

    Plcture 3: Sample 1 after splitting for measuring the depth of waterpenetration 5 mm

    Maximumpenetrationof water

    Maximumpenetrationof water

    E E

    D

    I!!Eil

    HE

    E

    Picture 4: after splitting for measuring the water penetration depth 2 mm

  • kiwatner Pro8reFs

    M 0190 I 2015Page 121 14

    Picture 5 Sample 3 after spllttlng for measurlng the depth of water 3 mm

    I Maximumpenetrationof water

    I

    t

  • l¡iwa@-M 0190 I 2015Page 13 I 14

    t

    I

    Picture 6: Sample 4 after 28 freeze thaw resistance, strongabgewitterte surface. No damage to the spacers.

    Picture 7: after 28 freeze thaw reslstance, strong abgewitterte surfaceNo damage to the spacer regonlzable

    T

    ¡ÍË,g[

    w

    EE

    n I nw

    IB

    U

    E

    4

    t,)a)

    EI

    T

    r

    ill

    EE

    HE

  • l¡iwaÞãrtnerE piofress

    M 0190 I 2015Page 141 14

    Picture 8: Test 6 after 28 freeze thaw resistance , strong abgewittertesurface, No damage to the spacer recognizable.

    I

    Titelblaetter-Abstandhalter-EN 17.pdf105PZ0101-INTGB-1215-Cast-Concrete-spacers_CDF.pdf