TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.:...

26
Page 1 of 114 REPORT NO.: LCS180502075AS TRF No. IEC60335_1X Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China Tel+(86)755-82591330 | Fax+(86)755-82591332 | E-mail[email protected] | http:// www.lcs-cert.com TEST REPORT IEC 60335-1 Safety of household and similar electrical appliances Report Number. .............................. : LCS180502075AS Date of issue ................................... : June 11, 2018 Total number of pages ................... : 114 Name of Testing Laboratory preparing the Report ...................... : Shenzhen LCS Compliance Testing Laboratory Ltd. 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue, Bao’an District, Shenzhen, Guangdong, China Applicant’s name ............................ : Shaoxing Naite Drive Technology Co., ltd. Address ........................................... : No.78 Xinsan Road, Sanjiang B Zone, Sanjiang Street, Shengzhou City, Zhejiang Province, China Test specification: Standard .......................................... : IEC 60335-1:2010/COR1:2010/COR2:2010 /AMD1:2013/COR1:2014/AMD2:2016/COR1:2016 Test procedure................................ : Australia safety Non-standard test method ............. : N/A Test Report Form No...................... : IEC60335_1X Test Report Form(s) Originator..... : Nemko AS Master TRF ...................................... : Dated 2016-10 Copyright © 2016 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report. D R A F T

Transcript of TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.:...

Page 1: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 1 of 114 REPORT NO.: LCS180502075AS

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

TEST REPORT

IEC 60335-1

Safety of household and similar electrical appliances

Report Number. .............................. : LCS180502075AS

Date of issue ................................... : June 11, 2018

Total number of pages ................... : 114

Name of Testing Laboratory

preparing the Report ...................... :

Shenzhen LCS Compliance Testing Laboratory Ltd.

1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue, Bao’an District, Shenzhen, Guangdong, China

Applicant’s name ............................ : Shaoxing Naite Drive Technology Co., ltd.

Address ........................................... : No.78 Xinsan Road, Sanjiang B Zone, Sanjiang Street, Shengzhou City, Zhejiang Province, China

Test specification:

Standard .......................................... : IEC 60335-1:2010/COR1:2010/COR2:2010

/AMD1:2013/COR1:2014/AMD2:2016/COR1:2016

Test procedure................................ : Australia safety

Non-standard test method ............. : N/A

Test Report Form No. ..................... : IEC60335_1X

Test Report Form(s) Originator ..... : Nemko AS

Master TRF ...................................... : Dated 2016-10

Copyright © 2016 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment

and Components (IECEE System). All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting

from the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed.

This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory

and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

General disclaimer:

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.

D R A F T

Page 2: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 2 of 114 REPORT NO.: LCS180502075AS

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Test item description ....................... : Electric Height Adjustable Desk

Trade Mark ........................................ : NATE

Manufacturer ..................................... : Shaoxing Naite Drive Technology Co., ltd.

No.78 Xinsan Road, Sanjiang B Zone, Sanjiang Street, Shengzhou

City, Zhejiang Province, China

Model/Type reference ...................... : NT33-2A3, NT33-2A2, NT33-2AR2, NT33-2A3, NT33-2AR3,

NT2A3S, NT33-2B3, NT33-2BR3, NT33-2B2, NT33-2BR2

Ratings .............................................. : Input: 240V~, 50/60Hz, 240W

Output: 24V , 5A

Testing procedure and testing location:

Testing Laboratory: Shenzhen LCS Compliance Testing Laboratory Ltd.

Testing location/ address ............................. : 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an

Avenue, Bao’an District, Shenzhen, Guangdong, China

Tested by (name + signature) ...................... : Kira Yang

Checked by(name + signature) .................... : Kizard Zhang

Approved by (name + signature) ................. : Hart Qiu

List of Attachments:

Attachment No.1: Australia and New Zealand DIFFERENCES AND NATIONAL DIFFERENCES for IEC 60335-1

Attachment No.2:

Product photos

Summary of testing:

Tests performed (name of test and test clause):

The submitted samples were found to comply with

the requirements of:

Electrical safety

IEC 60335-1:2010/COR1:2010/COR2:2010

/AMD1:2013/COR1:2014/AMD2:2016/COR1:2016

AS/NZS 60335.1: 2011+A1: 2012+A2: 2014+A3:

2015+A4:2017

Testing location:

Shenzhen LCS Compliance Testing Laboratory Ltd.

1/F., Xingyuan Industrial Park, Tongda Road, Bao’an

Avenue, Bao’an District, Shenzhen, Guangdong,

China

Summary of compliance with National Differences (List of countries addressed):

List of countries addressed: National Differences and Group Differences as per CB bulletin. See attachment

of National and Group Differences for details

The product fulfils the requirements of AS/NZS 60335.1: 2011+A1: 2012+A2: 2014+A3: 2015+A4:2017

D R A F T

Page 3: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 3 of 114 REPORT NO.: LCS180502075AS

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Copy of marking plate:

The artwork below may be only a draft. The use of certification marks on a product must be

authorized by the respective NCBs that own these marks.

Electric Height Adjustable Desk

Model: NT33-2B3

Input: 240V~, 50/60Hz, 240W

Output: 24V , 5A

Shaoxing Naite Drive Technology Co., ltd.

MADE IN CHINA

Remarks:

1. The height dimension of WEEE symbol should not less than 7mm.

D R A F T

Page 4: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 4 of 114 REPORT NO.: LCS180502075AS

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Test item particulars .................................................. :

Classification of installation and use ...................... : Stationary appliance, Class II

Supply Connection .................................................... : Appliance inlet

...................................................................................... :

Possible test case verdicts:

- test case does not apply to the test object ............ : N/A

- test object does meet the requirement .................. : P (Pass)

- test object does not meet the requirement............ : F (Fail)

Testing .......................................................................... :

Date of receipt of test item ......................................... : 2018-05-05

Date (s) of performance of tests ................................ : From 2018-05-05 to 2018-06-08

General remarks:

"(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report.

Throughout this report a comma / point is used as the decimal separator.

Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:

The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided ................................................................ :

Yes

Not applicable

When differences exist; they shall be identified in the General product information section.

Name and address of factory (ies) .......................... : Shaoxing Naite Drive Technology Co., ltd.

No.78 Xinsan Road, Sanjiang B Zone, Sanjiang

Street, Shengzhou City, Zhejiang Province,

China

General product information:

1. All test conducted at NT33-2B3, all models have the same constructions, electrical parameters and principles. They main differences between them are desktop sizes and model names.

2. The appliances power by AC-inlet. 3. The laboratory ambient for testing: 23.0-25.0°C, 60%-73%R.H 4.Model List:

Model Input Output Desktop sizes(L*W*H)

NT33-2A3 240V~, 50/60Hz, 240W 24V , 5A 140*70*65/130cm

NT33-2A2 240V~, 50/60Hz, 240W 24V , 5A 160*70*65/130cm

D R A F T

Page 5: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 5 of 114 REPORT NO.: LCS180502075AS

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

NT33-2AR2 240V~, 50/60Hz, 240W 24V , 5A 180*70*65/130cm

NT33-2A3 240V~, 50/60Hz, 240W 24V , 5A 140*80*65/130cm

NT33-2AR3 240V~, 50/60Hz, 240W 24V , 5A 160*80*65/130cm

NT2A3S 240V~, 50/60Hz, 240W 24V , 5A 180*80*65/130cm

NT33-2B3 240V~, 50/60Hz, 240W 24V , 5A 140*90*65/130cm

NT33-2BR3 240V~, 50/60Hz, 240W 24V , 5A 160*90*65/130cm

NT33-2B2 240V~, 50/60Hz, 240W 24V , 5A 180*90*65/130cm

NT33-2BR2 240V~, 50/60Hz, 240W 24V , 5A 180*100*65/130cm

D R A F T

Page 6: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 84 of 114 REPORT NO.: LCS180502075AS

IEC 60335-1

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Ambient, t2 (C) ................................................... : --

Temperature of winding: R1 (Ω) R2 (Ω) Δ T (K) T (C) Max. T (°C)

-- -- -- -- -- --

-- -- -- -- -- --

-- -- -- -- -- --

-- -- -- -- -- --

Supplementary information:

19.13 TABLE: Abnormal operation, temperature rises N/A

Thermocouple locations: Max. temperature rise

measured, Δ T (K)

Max. temperature rise

limit, Δ T (K)

--

--

-- -- --

-- -- --

Supplementary information:

21.1 TABLE: Impact resistance P

Impacts per surface Surface tested Impact energy (Nm) Comments

Three times Enclosure 0,5 No damage

Three times Display cover 0,5 No damage

Supplementary information:

24.1 TABLE: Critical components information P

Object / part

No.

Manufacturer/

trademark

Type / model Technical data Standard Mark(s) of

conformity1)

Power plug Shangyu Jintao

Electron Co Ltd

A2-10 250V~,10A AS/NZS 3112 ESO120467

Power cord SHANGYU

JINTAO

ELECTRON

CO .LTD

4V-75

H03VVH2-F

2×0.75mm2 AS/NZS 3191 ESV170111

AC Connector Shangyu Jintao

Electron Co Ltd

ST2 250VAC, 2.5A AS/NZS 60320.1 ESO130963

D R A F T

Page 7: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 85 of 114 REPORT NO.: LCS180502075AS

IEC 60335-1

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

AC Inlet (CON1) ZHEJIANG LECI

ELECTRONICS CO LTD

DB-8, 250VAC, 2.5A UL 498; IEC/EN 60320-1

UL E302229

VDE 40032028

(Alternative) ZHEJIANG BEI ER JIA ELECTRONIC CO. LTD

ST-A03-005 250VAC, 2.5A UL 498; IEC/EN 60320-1

UL E225980 VDE 40014833

(Alternative) Dongguan HUACONN Electronics Co., Ltd.

HC-88, SERIES

250VAC, 2.5A

UL 498; IEC/EN 60320-1

UL E340249 VDE 40032611

--Power supply

Fuse (F1) Dongguan Better

Electronics

Technology Co.,

Ltd.

932 T5AL, 250Vac DIN EN 60127-3;

DIN EN 60127-1;

IEC 60127-3;

IEC 60127-1

VDE

40033369

(Alternative) Hollyland Company Limited

5ET T5AL, 250Vac DIN EN 60127-3;

DIN EN 60127-1;

IEC 60127-3;

IEC 60127-1

VDE 40015669

(Alternative) XC Electronics (Shen Zhen) Corp. Ltd.

5TE T5AL, 250Vac DIN EN 60127-3;

DIN EN 60127-1;

IEC 60127-3;

IEC 60127-1;

UL 248-1;

UL 248-14

VDE 40029550

UL

E249609

X

Capacitor(CX1)

SHANTOU HIGH-

NEW

TECHNLOGY

DEVELOPMNT

ZONE SONGTIAN

ENTERPRISE CO

LTD

MPX Max .0.47µF,

275VAC, 110°C,

X2

UL 60384-14 UL

E208107

(Alternative) CHANGZHOU DEJIE OPTOELECTRONICS TECHNOLOGY CO LTD

MPX/MKP Max .0.47µF,

275VAC, 110°C,

X2

IEC/EN60384-14;

TUV

R50297652

D R A F T

Page 8: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 86 of 114 REPORT NO.: LCS180502075AS

IEC 60335-1

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

(Alternative) CHANGZHOU DEJIE OPTOELECTRONICS TECHNOLOGY CO LTD

MPX/MKP Max .0.47µF,

275VAC, 100°C,

X2

UL 60384-14 UL

E339764

(Alternative) Farad Electronics Co Ltd

PXK Max .0.47µF,

275VAC, 110°C,

X2

IEC/EN 60384-14;

UL 60384-14

VDE 40014111

UL

E247953

(Alternative) Liow Gu Electronics Industry Co Ltd

GS-L Max .0.47µF,

250VAC, 100°C,

X2

IEC/EN 60384-14 VDE 40023391

(Alternative) Liow Gu Electronics Industry Co Ltd

GS-L Max .0.47µF,

250VAC, 110°C,

X2

UL 60384-14 UL

E186321

(Alternative) Dain Electronic

Co., Ltd.

MPX Max .0.47µF,

275VAC, 110°C,

X2

IEC/EN60384-14;

UL 60384-14

UL

E147776

VDE 40018798

(Alternative) Jenn Fu

Electronics Corp

MPX Max .0.47µF, 275VAC, 110°C, X2

UL 60384-14 UL E184650

(Alternative) Winday Electronic

Industrial Co., Ltd.

MPX Max .0.47µF,

275VAC, 110°C,

X2

IEC/EN60384-14;

UL 60384-14

UL

E302125

VDE 40030283

NTC NANJING SHIHENG ELECTRONICS CO LTD

MF72-5D11 240V, 4A UL 1434; UL 60730-1; UL 60730-2-9;

UL E241319

(Alternative) HONGZHI ENTERPRISES LTD

5D-11 240V, 4A UL 1434; UL 60730-1; UL 60730-2-9;

UL E319959

(Alternative) THINKING

ELECTRONIC

INDUSTRIAL CO

LTD

SCK-054A 240V, 4A UL 1434; UL 60730-1;

UL 60730-2-9;

UL

E138827

D R A F T

Page 9: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 87 of 114 REPORT NO.: LCS180502075AS

IEC 60335-1

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

(Alternative) SHANTOU HIGH-

NEW

TECHNLOGY

DEVELOPMNT

ZONE SONGTIAN

ENTERPRISE CO

LTD

5D-11X 240V, 4A UL 1434; UL 60730-1;

UL 60730-2-9;

UL

E474052

Optical isolator (U2)

COSMO ELECTRONICS CORP

K1010; KP1010

250VAC, dti = 0.4mm, ext.cr ≥7.62mm, 100 °C

UL 1577 UL E169586

(Alternative) BRIGHT LED ELECTRONICS CORP

BPC-817S 250VAC, dti = 0.4mm, ext.cr ≥7.62mm, 100 °C

UL 1577 UL E236324

(Alternative) EVERLIGHT ELECTRONICS CO LTD

EL817 250VAC, dti = 0.4mm, ext.cr ≥7.62mm, 100 °C

UL 1577 UL E214129

(Alternative) SHARP CORP ELECTRONIC COMPONENTS AND DEVICES BU

PC123 250VAC, dti = 0.4mm, ext.cr ≥7.62mm, 100 °C

UL 1577 UL E64380

(Alternative) CT MICRO INTERNATIONAL CORPARATION

CT817 250VAC, dti = 0.4mm, ext.cr ≥7.62mm, 100 °C

UL 1577 UL E364000

Alternative LITE-ON TECHNOLOGY CORPORATION

LTV-817; LTV-817S2

Dti > 0.4mm, Ext.cr≥7.62mm,

100C

IEC/EN 60747-5-5

VDE 40015248

Alternative China Resources Semiconductor(SHENXHEN) LTD

PC817 Dti > 0.4mm, Ext.cr≥7.62mm,

100C

IEC/EN 60747-5-5

VDE 40042139

Varistor(MOV1) THINKING

ELECTRONIC

INDUSTRIAL CO

LTD

TVR14471 300Vac, 105C UL 1449 UL

E314979

(Alternative) Shaanxi Huaxing Electronic Co Ltd

MYG20G10K471T; MYG20G14K471T

300Vac, 105°C UL 1449 UL

E329651

(Alternative) Cerglass Mfg Inc 10D471K;

14D471K

300Vac, 125°C UL 1449 UL

E317616

(Alternative) Brightking (Shenzhen) Co Ltd

10D471K; 14D471K

300Vac, 105°C UL 1449 UL

E327997

D R A F T

Page 10: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 88 of 114 REPORT NO.: LCS180502075AS

IEC 60335-1

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

(Alternative) Hongzhi Enterprises Ltd.

HEL10D471K;

HEL14D471K

300Vac, 105°C UL 1449 UL

E324904

(Alternative) Shantou High-New Technology Development Zone Songtian Enterprise Co Ltd

10D471K; 14D471K

300Vac, 125°C IEC 61051-1 IEC 61051-2

UL 1449

UL

E330837

Y

Capacitor(CY1,

CY2)

SHANTOU HIGH-

NEW

TECHNOLOGY

DEVELPMNT

ZONE SONGTIAN

ENTERPRISE CO

LTD

CE 250VAC,

MAX.4700 pF,

125°C, Y2 type

UL 60384-14 UL

E208107

(Alternative) GCE (Dongguan) Electronics Co., Ltd

G Y2 AC 250V or AC 300V , Max.4700pF,

Min. 125C, Y2 type

IEC/EN60384-14;

UL 60384-14

VDE 40040783

UL

E464834

(Alternative) JYH CHUNG ELECTRONIC CO.,LTD

JY AC 300V Max.4700pF,

Min. 85C, Y2 type

IEC/EN60384-14;

UL 60384-14

VDE

123326

UL

E187963

(Alternative) Zonkas Electronic Co., Ltd.

ZE AC 300V

Max.4700pF,

Min. 125C, Y2 type

IEC/EN60384-14;

UL 60384-14

VDE 40020372

UL E258931

(Alternative) HSUAN TAI ELECTRONICS CO LTD

CY AC 250V, Max.4700pF,

min. 85C, Y2 type

IEC/EN60384-14 VDE 118413

Transformer(T3) Xsft Electronics Co., Ltd

SPM-120C-PCB1-3

Class B IEC 60335-1 Tested with appliance

(Alternative) Shenzhen Fulight Thailand Electronic Technology Co Ltd

SPM-120C-PCB1-3

Class B IEC 60335-1 Tested with appliance

-Bobbin SUMITOMO

BAKELITE

CO.,LTD

PM-9820 V-0,150 C,

Min.thick:0,7mm

UL 94;

UL 1694;

UL 723

UL

E41429

D R A F T

Page 11: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 89 of 114 REPORT NO.: LCS180502075AS

IEC 60335-1

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

(Alternative) CHANG CHUN PLASTICS CO LTD

T355J/T375J V-0,150°C,

Min.thick:0,7mm

IEC 60335-1;

UL 94;

UL 1694;

UL 723

Tested with

Appliance

UL

E59481

(Alternative) CHANGSHU SOUTH-EAST PLASTIC CO LTD

PF2A5-151J(b)

V-0,150°C,

Min.thick:0,7mm

IEC 60335-1;

UL 94;

UL 1694;

UL 723

Tested with

Appliance

UL

E136137

-Winding Tai-I Electric Wire & Cable Co Ltd

UEW 130°C UL 1446 UL

E85640

(Alternative) Dong Guan Xin You Lian Copper Co Ltd

2UEW 130°C UL 1446 UL

E222363

(Alternative) Huizhou Zhaoxinyuan Electronics Technology Co Ltd

*UEW 130°C UL 1446 UL

E344738

(Alternative) SHANTOU SHENGANG ELECTRICAL INDUSTRIAL CO LTD

UEW/130 130°C UL 1446 UL

E239508

(Alternative) PACIFIC ELECTRIC WIRE & CABLE (SHENZHEN) CO LTD

UEW/U 130°C UL 1446 UL

E201757

-Insulating tape

3M COMPANY 1350F-1(b);

1350F-2(c) 130°C UL 510A UL

E17385

(Alternative) Jingjiang Yahua Pressure Sensitive Glue Co Ltd

CT-280B, PZ 130°C UL 510A UL

E165111

-Varnishes Elantas Electrical Insulation Elantas Pdg

468-2(d) 130°C UL 1446 UL

E75225

(Alternative) SUZHOU TAIHU ELECTRIC ADVANCED MATERIAL CO LTD

T-4260(a) 130°C UL 1446 UL

E228349

D R A F T

Page 12: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 90 of 114 REPORT NO.: LCS180502075AS

IEC 60335-1

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

(Alternative) ELANTAS ELECTRICAL INSULATION ELANTAS PDG INC

468-2(d) 130°C UL 1446 UL

E75225

-Three insulated

wire Furukawa Electric Co Ltd

TEX-E 130°C UL 2353 UL

E206440

(Alternative) Totoku Electric Co Ltd

TIW-2 130°C UL 2353 UL

E166483

(Alternative) SUZHOU YUSHENG ELECTRONIC CO LTD

TIW-B 130°C UL 2353 UL

E332529

-Insulating tube Fluo Tech Industries Co., Ltd.

TFT; TFL 200°C UL 224 UL

E175982

(Alternative) Great Holding Industrial Co Ltd.

TFL 200°C UL 224 UL

E156256

(Alternative) CHANGYUAN ELECTRONICS GROUP CO LTD

CB-TT-T 200°C UL 224 UL

E180908

Relay (K1) TAIWAN SHORI

ELECTRIC CO

LTD

S5H-5B-1AS;

S5H-5B-1BS

Rated 5A, 30Vdc;

10A, 125Vac; 5A,

250VAC

UL 508;

UL 60947-1;

UL 60947-4-1

UL

E188091

(Alternative) Xiamen Hongfa Electroacoustics Co., Ltd.

HF32F 10A, 125VAC; 5A, 250VAC

IEC/EN61810-1 VDE 40012204

(Alternative) Ningbo Zettler Electronics Co Ltd

JT32Fb AC 250V, 5 A, EN 61810-1 TUV R50265552

PCB Kingboard Laminates Holdings Ltd

KB-5150 V-0, 130°C, min. 1.3mm thickness

UL94; UL 746

UL E123995

(Alternative) Shandong Jinbao Tech-innov Corporation

ZD-95(G)F1 V-0, 130°C min. 1.3mm thickness

UL94; UL 746

UL E141940

Motor Zhoushan Donghai

Motor Industry Co.,

Ltd.

ZYT45JS-2 DC18V,4500rpm

4.8A, Class A

IEC 60335-1 Test with

appliance

DC cord(CON2)

(CON3)

DONGGUAN FUYU WIRE CO LTD

1007 300V 80°C, 24AWG

UL785 UL E478679

D R A F T

Page 13: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 91 of 114 REPORT NO.: LCS180502075AS

IEC 60335-1

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

(Alternative) SHENZHEN DIANZHIZHOU ELECTRIC PRODUCTS CO LTD

1007

300V 80°C, 24AWG

UL785 UL E479504

PCB(for control

panel)

Kingboard Laminates Holdings Ltd

KB-5150 V-0, 130°C,

min.1.6mm

thickness

UL94 UL E123995

PCB(for motor) Kingboard Laminates Holdings Ltd

KB-5150 V-0, 130°C,

min.1.6mm

thickness

UL94 UL E123995

Enclosure Casetek

Computer

(Suzhou) Co., Ltd.

GE V-0, 130°C UL 94,

UL 746

UL

E229835

Supplementary information:

1) Provided evidence ensures the agreed level of compliance. See OD-CB2039.

28.1 TABLE: Threaded part torque test P

Threaded part

identification:

Diameter of thread

(mm)

Column number

(I, II, or III)

Applied torque (Nm)

Fixed enclosure 3.92 II 1.2

Supplementary information:

29.1 TABLE: Clearances P

Overvoltage category .................... ................ ... :

Type of insulation:

Rated

impulse

voltage (V):

Min. cl (mm) Basic

(mm)

Supplementary

(mm)

Reinforced

(mm)

Functional

(mm)

Verdict /

Remark

330 0,2* / 0,5 / 0,8** -- -- -- -- N/A

500 0,2* / 0,5 / 0,8** -- -- -- -- N/A

800 0,2* / 0,5 / 0,8** -- -- -- -- N/A

1 500 0,5 / 0,8** / 1,0*** -- -- -- -- N/A

2 500 1,5 / 2,0*** >1.5 >1.5 -- >1.5 P

4 000 3,0 / 3,5*** -- -- >3.0 -- P

6 000 5,5 / 6,0*** -- -- -- -- N/A

8 000 8,0 / 8,5*** -- -- -- -- N/A

10 000 11,0 / 11,5*** -- -- -- -- N/A

D R A F T

Page 14: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 102 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: Exterior view for model NT33-2B3

Details of: Detail view for model NT33-2B3

D R A F T

Page 15: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 103 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: Exterior view for Lifting column

Details of: Detail view for Lifting column

D R A F T

Page 16: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 104 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: Internal view for Lifting column

Details of: Internal view for Lifting column

D R A F T

Page 17: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 105 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: Internal view for Lifting column

Details of: Exterior view for Power Control Box

D R A F T

Page 18: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 106 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: Detail view for Power Supply Control Box

Details of: Detail view for Power Supply Control Box

D R A F T

Page 19: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 107 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: Internal view for Power Supply Control Box

Details of: Internal view for Power Supply Control Box

D R A F T

Page 20: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 108 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: PCB view for Power Supply Control Box

Details of: PCB view for Power Supply Control Box

D R A F T

Page 21: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 109 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: PCB view for Power Supply Control Box

Details of: PCB view for Power Supply Control Box

D R A F T

Page 22: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 110 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: PCB view for Power Supply Control Box

Details of: Exterior view for Controller

D R A F T

Page 23: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 111 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: Detail view for Controller

Details of: Internal view for Controller

D R A F T

Page 24: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 112 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: PCB view for Controller

Details of: PCB view for Controller

D R A F T

Page 25: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 113 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: DC cord view

Details of: Power cord view

D R A F T

Page 26: TEST REPORT IEC 60335-1 Safety of household and similar ... · Page 84 of 114 REPORT NO.: LCS180502075AS IEC 60335-1 Clause Requirement + Test Result - Remark Verdict TRF No. IEC60335_1X

Page 114 of 114 REPORT NO.: LCS180502075AS

Attachment No.2

TRF No. IEC60335_1X

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China

Tel:+(86)755-82591330 | Fax:+(86)755-82591332 | E-mail:[email protected] | http:// www.lcs-cert.com

Details of: Plug view

END OF REPORT

D R A F T