TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 1Personal et confidential
Megohmmeters 5kV
C.A 6545 / C.A 6547
SALES PRODUCT INFORMATION
Electrical testing and safetyCécile Le Goué
TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 2Personal et confidential
The Experts in insulation at 5kV
TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 3Personal et confidential
Measurements
C.A 6545 C.A 6547INSULATION
Predetermined test voltages :
500-1000-2500-5000V
Programmable test voltage :
40 à 5100V (pas 10V/100V)
VOLTAGE
CAPACITANCE
LEAKAGE CURRENT
30 k…10 T
10 k…10 T
25…5100 V DC (15..500 Hz)
0,005…49,99 µF
0,000…3000 µA
TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 4Personal et confidential
Functional specifications
C.A 6545 C.A 6547
Automatic calculation of DAR & PI ratios
Automatic calculation of DD (Dielectric Discharge test)
Programming of test duration
R(t) function Limited to 20 samples With 128 kbyte
SMOOTH function
Programmable alarms
Exact test voltage measured
Yes, DAR & PI
Yes, DD = I1mn / (Test voltage x C)
Yes
Yes
Yes
Yes
TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 5Personal et confidential
Other specifications
C.A 6545 C.A 6547Memory - Yes, with 128 kbyte
RS232 - Yes, bi-directionnal
Supply
Battery charge status indicator
Backlit screen + bargraph
Electrical safety
Dimensions
Weight
270 x 250 x 180 mm
4 300 g
NiMH rechargeable battery
Yes
Yes
IEC 1010-1 Cat.III 1000V (or Ca.I 2500V) + EN 61557
TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 6Personal et confidential
A site-adapted hard casing, IP 67 when closed and IP 53 when
opened
A tool-bag containing all accessories
Clamps and plugs are perfectly insulated and measurement leads are 3m long.A 3m guard lead is also supplied for high-insulation measurements.
A special built-for-the-field design
TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 7Personal et confidential
A studied ergonomic design
A giant backlit LCD screen with digital display + bargraph
Test voltage selection by rotary switch:• 4 pre-determined test voltages:
500 V1000V2500V5000V
• 1 programmable test voltage position: 40 to 5100V in 10V or 100V steps
Measurement and function selection by pressing on a push-button
TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 8Personal et confidential
For an excellent quantitative analysis...
and qualitative analysis...
INSULATION measurement to 10 T
VOLTAGE measurement to 5100 V
CAPACITANCE measurement of the tested circuit
LEAKAGE CURRENT measurement
automatic calculation of DAR, PI and DD ratios
R(t) graph plotting
TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 9Personal et confidential
Reminder
Insulation resistance measurement qualifies the degree of insulation in installations or equipment. It also serves as a basis for preventive maintenance.
Insulation measurement is very sensitive to variations in temperature and humidity. While testing, measurement is also initially influenced by unwanted currents.
So, it is best to carry out :
quantitative measurement of long duration: provided by mode "Time-controlled testing"
and R(t) graph plotting
a qualitative analysis with calculation of DAR, PI and DD ratios.
TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 10Personal et confidential
DAR, PI ?A qualitative analysis can turn out to be more clever and reliable than a simple quantitative analysis: the calculation of DAR and PI ratios enable the user to ignore climatic conditions and unwanted currents liable to invalidate measurement results.
reminder : DAR = R 1mn / R 30s & PI = R 10mn / R 1mn
DD ?This test is especially suited for measurement on heterogeneous and multi-layer insulation, for it can reveal a defective layer among layers with high resistance. We recommend charging the insulator with 500V for 30 minutes.
DD = I1mn (current measured after 1mn (mA))
Test voltage (Volt) x Capacitance measured (Farad)
R(t) graph plotting :
when a time-controlled test begins, measured insulation samples are automatically memorized. It is possible to follow insulation evolution in function to the test voltage's application duration. Then R(t) graph can then be plotted out either by hand or directly on a PC screen using the MégohmView software.
Reminder
TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 11Personal et confidential
To order
C.A 6545…………………………………………P01.1397.01
C.A 6547…………………………………………P01.1397.02
delivered complete with tool-bag containing accessories : - 2 x 3 m safety leads with HV plug and HV crocodile clip (red/blue) - 1 x 3 m safety guard lead with HV rear pick up plug and HV crocodile clip (black)- 1 x 0.35 m rear pick up lead (blue)- 1 x 2 m mains supply lead- 1 user's manual in 5 languages code 689 439 A00- 5 plastic-coated, two-sided condensed user's manual
TEST & MEASUREMENT DIVISION
PC_F_ CA 6545/47 - 12Personal et confidential
Accessories & replacement parts
8 m HV blue crocodile clip lead P01.2952.148 m HV red crocodile clip lead P01.2952.15 8 m HV black crocodile clip rear pick up lead P01.2952.1615 m HV blue crocodile clip lead P01.2952.1715m HV red crocodile clip lead P01.2952.18 15 m HV black crocodile clip rear pick up lead P01.2952.19PC Software for C.A 6547 P01.1019.38ASerial printer P01.1029.03Serial-to-parallel adapter P01.1019.413 x 3m HV crocodile clip leads (blue / red / guarded black) P01.2952.200.35 m rear pick up lead (blue) P01.2952.21Tool-bag P01.2980.612 m mains supply lead P01.2951.74