TERMO ELECTRIC BOILERS MANUAL OSO TERMO RS -E OSO TERMO PLUS - E OSO TERMO PTV – E B C

Transcript of TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and...

Page 1: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

TERMO ELECTRIC BOILERS

MANUAL

OSO TERMO RS -E

OSO TERMO PLUS - E

OSO TERMO PTV – E

B C

Page 2: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers
Page 3: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Contents

1. Introduction ....................................................................................................................... 1

1.1. Applicable documents................................................................................................. 1 1.2. Retention of documents .............................................................................................. 1 1.3. Features and benefits ................................................................................................. 1 1.4. Termo concept. ........................................................................................................... 1 1.5. Outside temperature sensor........................................................................................ 1 1.6. Heating curves............................................................................................................ 1 1.7. Termo E Range........................................................................................................... 2 1.8. Water heater temperature sensor ............................................................................... 2

2. Termo E range .................................................................................................................. 1

2.1. Key to TERMO boilers ................................................................................................ 1 2.1.1. RS - E................................................................................................................... 1

2.1.2. Plus - E .................................................................................................................... 3 2.1.3. PTV - E .................................................................................................................... 5 2.2. Expansion Vessel Characteristics (Plus And PTV Boilers) .......................................... 7 2.3. Supply Characteristics 240V N ~ 50/60 Hz ................................................................. 7

3. Installation ......................................................................................................................... 8

3.1. Content included in delivery ........................................................................................ 8 3.2. Standards & Regulations ............................................................................................ 8 3.3. Physical installation..................................................................................................... 8 3.3.1. Select position for boiler ....................................................................................... 9 3.3.2. Fitting the boiler hanging bracket.......................................................................... 9 3.3.3. Recommendations for handling ............................................................................ 9 3.3.4. Removing/fixing the front and top case................................................................10

3.4. Plumbing & Heating installation & commissioning ......................................................10 3.4.1. Installation ...........................................................................................................10 3.4.2. Ancillary components ..........................................................................................10

3.5. Connection to the electrical mains supply ..................................................................11 3.6. Room thermostat, temperature probes and pumps connection ..................................12 3.6.1. Connect room thermostat/programmer ................................................................12 3.6.2. Fit external temperature sensor ...........................................................................12 3.6.3. Fitting hot water cylinder temperature sensor (PTV-E only) .................................13

3.6.4. Fitting pump connections and expansion vessel (RS – E only) ...............................13 4. Setting up Boilers .............................................................................................................14

4.1. Control Panel (including fault finding indicators).........................................................14 4.2. Choose type of heating (radiator or under floor heating) ............................................15 4.2.1. Hybrid Systems combining radiator and UFH ......................................................16

4.3. Activating system and programming central heating ..................................................16 4.3.1. Heating curves explained. ...................................................................................16 4.3.2. To set correct curve.............................................................................................17 4.3.3. Setting internal temperature ................................................................................17 4.3.4. Programmable room thermostats & setting variable internal temperatures ..........17

5.4. Domestic hot water priority.........................................................................................18 4.5. Protection from freezing .............................................................................................18 4.5.1. Domestic hot water..............................................................................................18

4.5.2. Central heating........................................................................................................18 5. Recommended annual checks (all boilers) .......................................................................19

6. Central heating controls advanced menu..........................................................................20

Page 4: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

6.1. Domestic hot water advanced menu (control panel type 2) ........................................22 7. Fault finding guide ............................................................................................................24

8. After Sales service information .........................................................................................30

9. Cascade power limiter ......................................................................................................30

10. OSO Hotwater UK Ltd ....................................................................................................30

11. Appendices.....................................................................................................................30

11.1. Appendix 1 - Termo RS with space heating and water heating ................................31 11.1.1. Schematic diagram Termo RS - E .....................................................................31 11.1.2. Wiring diagram Termo RS - E............................................................................31 11.1.3. S-Plan wiring layout Termo RS -E .....................................................................32

11.2. Appendix 2 - Termo RS – Space heating only..........................................................33 11.2.1. Schematic diagram Termo RS - E .....................................................................33 11.2.2. Wiring diagram Termo RS-E..............................................................................33 11.2.3. S-Plan wiring layout Termo RS-E ......................................................................34

11.3. Appendix 3 - Termo PLUS E ....................................................................................35 11.3.1. Schematic diagram Termo plus-E......................................................................35 11.3.2. Wiring diagram Termo plus-E ............................................................................35 11.3.3. S-Plan wiring layout...........................................................................................36

11.4. Appendix 4 Termo PTV E ........................................................................................36 11.4.1. Schematic diagram Termo PTV-E .....................................................................36 11.4.2. Wiring diagram Termo PTV-E............................................................................36 11.4.3. S- Plan wiring layout Termo PTV-E ...................................................................37

Page 5: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 1

Terminology used in this manual The central heating boiler water circuit is called primary The domestic hot water is called secondary (dhw)

1. Introduction Thank you for purchasing the Oso Termo E electric central heating boiler.

To ensure a correct and safe installation and economical use, please read these instructions thoroughly before installation.

1.1. Applicable documents

The following additional documents are provided with the appliance: For the owner of the system: Instructions for use Warranty card

For the qualified technician: Instructions for installation Electrical drawing for the appliance

1.2. Retention of documents

Please pass on this installation manual to the owner of the system. The owner should retain the manuals so that they are available when required.

1.3. Features and benefits

The boiler provides wet system central heating by passing the primary water over the immersion heaters. The immersion heaters are located on the under-side of boiler ensuring the elements are constantly immersed in the heating medium (water with appropriate inhibitor). The primary temperature in the heating circuit is determined by the outside temperature sensor and the heating curve selected in the boiler, (see sections 1.2, 1.3 and 3.5.3) The boiler temperature probe will activate and modulate 1, 2 or 3 elements in the boiler to achieve the desired primary temperature. The boiler has an automatic pump overrun for both central and water heating that prevents a build up of heat in the boiler. The boiler reservoir is insulated with 19 mm self-extinguishing Armaflex insulating material, which is sufficient to direct the whole heat only to the heating system.

The boiler operates by rapidly heating a small water quantity. Energy use is maintained at 100% efficiency.

No flue or fan required - Almost silent in operation - No bulk oil storage tanks required

No annual safety check required

1.4. Termo concept.

The OSO Termo E range of boilers uses technology widely used in Europe but relatively new in the UK, that modulates the boiler to reduce power consumption.

1.5. Outside temperature sensor

An outside temperature sensor is supplied with the boiler to be fitted to an outside shaded wall. This sensor informs the boiler of the outside temperature.

1.6. Heating curves

The boiler is pre-programmed with a number of heating curves to select from.

The boiler calculates the heat required in the property based on the outside temperature and the set heating curve – the colder it is outside, the higher the primary temperature needed in the heating system.

Heating curves are set for a particular property and selection is dependent on the insulation levels of the property. Modern, well insulated buildings have a different heating curve to a less well insulated building. A poorly insulated house will require a higher primary heating temperature.

Heating curves also vary according to radiator or under-floor heating. The factory set heating curve is for a building constructed to 2000 building regulations with radiator heating. Many boilers therefore will not require adjustment of heating curve.

Changing the heating curves at the time of installation is a simple process for the installer. A table is shown on page 20 indicating which heating curve is required for the building type. Once the heating curve is correctly set, it should never require changing.

The heating curve will aim for the property to be heated to 22°C. Not all households wish for the same internal temperature, if the residents of the property require a higher or lower temperature, the selected curve should be offset up or down by the appropriate number of degrees. Full instructions are given on page 19.

A room thermostat (not supplied) must be installed to finely regulate internal temperatures.

Page 6: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 2

1.7. Termo E Range

TERMO RS E is a boiler and software package only. Expansion vessel, pump and motorized valves are not supplied

TERMO Plus E is a system boiler for central heating only. Expansion vessel & pump is supplied in the boiler.

TERMO PTV E is a system boiler for central heating and will provide heat for a domestic hot water cylinder. For ease of reference the boilers will be referred to in this installation manual as RS E, Plus E and PTV E.

TERMO boilers are available in (240V single phase): 4.8, 6, 7.2, 10.8, and 14.4 kW. OSO Termo boilers can be connected together to provide more power, the boilers can also be supplied for use on three phase supplies. Please contact Oso for details.

1.8. Water heater temperature sensor

The Termo PTV E boiler is supplied with a temperature probe that is inserted between the cylinder wall and insulation or in a dry pocket. This probe then relays cylinder temperature information back to the boiler. The boiler will then produce sufficient heat to raise the temperature of the domestic water to the desired level.

Page 7: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 1

2. Termo E range

2.1. Key to TERMO boilers

2.1.1. RS - E

1. Primary flow

2. Primary return

3. External boiler jacket

4. Boiler

5. Armaflex Insulation

6. Immersion heaters

7. Control panel

8. Cable entry point

9. Contactors and RCD switch

10. Charge and discharge val ve

11. Pocket with temperature probe

12. Safety valve (supplied loose)

13. Drain valve (not supplied)

14. Isolation valves (not supplied)

15 Manual venting valve (not supplied)

Page 8: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 2

RS – E

Technical Data For RS E

Power

kW

Boiler

Capacity

Litres

Dimensions

mm

Dry Weight

kg

Maximum primary operating pressure

MPa (bar)

Connection BSP male

Power supply

4.8

6

7.2

10.8

14.4

6

A 330

B 750

C 230

D 100

E 57

F 126

21.4 0,25 (2,5) ¾” 240V N ~ 50/60 Hz

Page 9: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 3

2.1.2. Plus - E

1. Primary flow

2. Primary return

3. External boiler jacket

4. Boiler

5. Armaflex insulation

6. Electrical heaters

7. Control panel

8. Cable entry point

9. Contactors

10. Expansion vessel

11. Circulation pump

12. Safety valve 2.5 bar

13. Automatic air vent (AAV)

14. Charge and drain valve

15. Boiler venting valve

16. Air-indicator

17. Manifold

18. RCD switch

19. Pocket with temperature probe

20. Pressure probe

Page 10: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 4

Plus – E

Technical Data For Plus E Boilers

Power

kW

Boiler

Capacity

Litres

Expansion

vessel

L/bar

Dimensions

Mm

Dry Weight

kg

Maximum primary

operating pressure

MPa (bar)

Connection BSP male

Power supply

4.8

6

7.2

10.8

14.4

6 8 / 0,8

A 330 B 930 C 230 D 100 E 65 F 320

34.5 0,25 (2,5) ¾” 240V N ~ 50/60 Hz

Page 11: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 5

2.1.3. PTV - E

1. Primary flow

2. Primary return

3. External boiler jacket

4. Boiler

5. Armaflex insulation

6. Electrical heaters

7. Control panel

8. Cable entry point

9. Contactors

10. Expansion vessel

11. Circulation pump

12. Safety valve 2.5 bar

13. Automatic air vent (AAV)

14. Charge and drain valve

15. Boiler venting valve

16. Air-indicator

17. Manifold

18. RCD switch

19. Pump for water cylinder

20. Primary flow for water cylinder

21. Pocket for temperature probes

22. Pressure probe

Page 12: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 6

PTV- E

Technical Data For PTV- E Boilers

Power

kW

Boiler

Capacity

Litres

Expansion

vessel

L/bar

Dimensions

Mm

Dry Weight

kg

Maximum primary

operating pressure

MPa (bar)

Connection

BSP male

Power supply

4.8

6

7.2

10.8

14.4

10 10/0,8

A 400

B 930

C 230

D 150

E 65

F 150

G 50

H 305

44.2 0,25 (2,5)

¾” cylinder

1” (heating)

240V N ~ 50/60 Hz

Page 13: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 7

2.2. Expansion Vessel Characteristics (Plus And PTV Boilers)

Volume of Expansion

Vessel L

Maximum Expansion

Vessel Pressure

MPa (bar)

Filling Pressure

MPa (bar)

Maximum Pressure In heating System

MPa (bar)

Max Height Difference in central Heating System

m

Effective capacity of Expansion

Vessel L

Adsorption Capacity

%

Maximum amount of water in primary system

L

Maximum power of

Boiler

kW

8 4.0 114 14.4

10

0.4 (4) 0.08 (0.8) 0.3 (3) 10

5.0

50%

143 14.4

Values are related to working temperature range from 10�C to 90�C.

2.3. Supply Characteristics 240V N ~ 50/60 Hz

POWER nominal current

MCB Rated short-circuit breaking capacity Icn (EN 60898)

Rated short-circuit breaking capacity Icn (IEC 947-2)

Cable size* RCD switch type

4.8 kW 20 A B25-1 25-2/0.03 A

6 kW 25 A 3 x 4 mm

2

7.2 kW 30 A B32-1

3 x 6 mm2

40-2/0.03 A

10.8 kW 45 A B50-1 63-2/0,03A or 40-4/0.03 A

14.4 kW 60 A B63-1

10 kA 15 kA

3 x 10 mm2

80-2/0,03A or 63-4/0.03 A

*min. conductor's cross-section in mm2 is based on maximum length of 20 m.

Page 14: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 8

3. Installation

3.1. Content included in delivery

TERMO boilers are delivered pre-assembled. Check that all parts have been delivered intact. For exact list of parts see figure and table below. If parts are damaged or missing, please consult OSO Hotwater UK Ltd.

Contents included within delivery

Item Quantity Description

1 1 TERMO boiler

2 1 Instructions and warranty card

3 1 (2) Hanging bracket

4 1 External temperature sensor

5 1 Water cylinder temperature sensor (standard for PTV - E, optional for RS- E)

6 1 Pressure relief valve (In case of Termo Plus and Termo PTV it is already fitted on boiler, In case of Termo RS it is supplied loose)

3.2. Standards & Regulations

The OSO Termo range of boilers are BEAB approved and CE marked.

Health and Safety at Work Act 1974 - When working with Termo boilers, ensure that protective clothing and equipment is used appropriate to parts that may considered hazardous to health and safety.

Control of Substances Hazardous to Health (COSHH 1988) - Glues, paints and sealants are used in the manufacture of this product and present no known hazards when used in the manner for which they are intended.

The guarantee is only valid if the following conditions are observed: The boiler must be installed by a registered engineer to comply with current building regulations, current IEE electrical wiring regulations (BS 7671), local authority regulations, water supply regulations and health and safety at work regulations. Other Relevant British/European standards should be adhered to, including; BS 5449 - Specification for forced circulation hot water central heating for domestic premises, BS 7593, treatment of water in domestic hot water central heating systems Recommended pressure of central heating installation is 1.5 bar, maximum operating pressure is 2.5 bar.

3.3. Physical installation

IMPORTANT – MOVING, POSITIONING AND INSTALLING THE BOILER EXCEEDS THE RECOMMENDED WEIGHT FOR A ONE MAN LIFT.

The boiler must be handled and transported carefully and stored in a safe, dry place.

Plus - E, PTV - E and RS – E are designed for wall installation in an upright position. Fixed wall brackets are provided on the back of the boiler. The boiler should be fixed in position on a suitable load-bearing wall prior to pipe connection.

The boiler should be fitted in a dry place not subject to extremes of temperature. Cylinder cupboards and kitchens are acceptable but bath or showers rooms are not.

Page 15: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 9

3.3.1. Select position for boiler

The boiler should preferably be installed on the lowest point in relation to the installation. This ensures that elements are always immersed in water and there is no danger of burning out.

When positioning the boiler, ensure there is adequate surrounding space to allow for pipe connection, ventilation, servicing and replacement of components. Refer to the diagram below for guidance.

Access is required to the control panel connections at underside of the boiler and the power supply connection, located at left bottom side of boiler. Ensure that bottom part of boiler is accessible to change the immersion element.

Ensure the boiler is in a location where it will not be affected by water drips or splashing.

Ensure that ventilation to the boiler is not impeded by towels, linen etc placed very close to the boiler. Do not place towels or linen on top of the boiler.

The figure below shows minimum recommended clearances.

Recommended minimum clearances.

3.3.2. Fitting the boiler hanging bracket Fix the hanging bracket (see page 12 No. 3) to the wall using suitable plastic plugs and M8 or M10 screws (not supplied). Decide the position of the bottom of the boiler, giving due consideration to the recommended minimum clearance and then drill holes to accept the boiler mounting plate. Screw points should to be drilled the following distances above the bottom of the boiler casing RS – E 624mm Plus – E 610mm PTV – E 625mm

3.3.3. Recommendations for handling Clear the route before attempting the lift. Ensure safe lifting techniques are used – keep back straight – bend using legs. Keep load as close to body as possible. Do not twist – reposition feet instead. If 2 persons performing lift, ensure coordinated movements during lift. Avoid upper body/top heavy bending - do not lean forward/sideways. Oso recommend wearing suitable cut resistant gloves with good grip to protect against sharp edges and ensure good grip. Always use assistance if required.

Wall mounting

Important Note: If the boiler is to be fitted in a timber framed building ensure that the bracket is secured to a substantial part of the timber frame capable of taking the weight of the boiler.

Positioning of Appliance for Final Installation (See diagram above) Lift up boiler (3) above hanging bracket (2), gently lean it to the wall (1) and slide it down to hanging bracket (2).

2

1 3

Page 16: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 10

3.3.4. Removing/fixing the front and top case

Grasp the front case by its sides, pull it towards the front and remove it by lifting it off the unit, push top cover towards back and lift it off the unit.

3.4. Plumbing & Heating installation & commissioning

3.4.1. Installation

On RS - E boilers fit the supplied safety valve to the heating return point on the installation– see point 12 page 4 diagram. Ensure that no valve is placed between the safety valve and the boiler.

To avoid draining the entire primary system during boiler maintenance it is recommended that isolation valves are fitted to the flow and return pipes immediately below the boiler.

Connect the primary flow and return pipes for the central heating system to the labeled connections on the boiler.

Connect the mains water supply via a filling loop to the charge and discharge valve on the boiler incorporating a stop valve and double check valve which must be left disconnected after commissioning.

Drain taps must be located in accessible positions which permit the draining of the whole system including the primary and the secondary (dhw) system.

Any water loss from the system should be replaced from the filling loop connection.

When draining the boiler allow air in using the boiler venting valve. Do not drain the boiler by opening the pressure relief valve.

All capillary joints in all DHW pipework must be made with lead free solder.

The Plus - E and PTV - E are self contained system boilers that manage heating flow to the radiators and or under floor. The PTV – E also supply heat to a domestic hot water cylinder. External motorized valves are not required (excepting when a PTV – E is connected to an Unvented Water Heater) and therefore systems such as S & Y plan are not applicable. As motorized valves are not used a bypass is not normally required. Product diagrams on pages 6 & 8 display the expansion vessel and pumps.

Plus - E and PTV – E can also be used on an open vented central heating system.

Wherever possible all pipe work should be insulated to help prevent heat loss and possible freezing, particularly where pipes are run through roof spaces and ventilated under-floor spaces.

3.4.2. Ancillary components

On RS - E boilers a boiler pressure gauge, circulation pump and expansion vessel must be fitted, see diagram page 6. The expansion vessel should be sized to the total system volume. The water capacity of the boiler itself is 6 liters.

Diagram of recommned pump on RS-E for radiator heating Diagram of recommned pump on RS-E for underfloor heating

If the capacity of the in built expansion vessel on Plus - E & PTV - E is not sufficient for the heating system (indicated by pressure increase of 0.6bar when system is heated), an additional expansion vessel can be installed external to the boiler. This should be fitted to the return pipe as close as possible to the boiler.

To comply with Part L of building regulations, a room thermostat must be fitted with the boiler. This will work in conjunction with the boiler software and outside temperature sensor to finely control the temperature in the

Page 17: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 11

dwelling and minimize energy consumption. The room thermostat should not be sited in direct sunlight or close to any heat source such as radiators. Thermostatic radiators valves may also be used, but should not be fitted in the same room as the room thermostat.

After the central heating circuit has been installed open all service valves, flush pipes through and check for leaks before commissioning and introduce the correct inhibitor for a central heating circuit in accordance with BS7593. Commission the boiler slowly to allow air to escape through the automatic air vent. Remove air from pump using front screw on pumps.

Pressurize the system to 1.5 bar.

Where the boiler is being retro-fitted to an existing installation, it is equally important to flush the system and commission using inhibitor to BS7593.

TERMO boilers are fitted with an automatic and manual air vent. The boilers are also equipped with an air-indicator which detects the presence of air in the boiler. If air is detected and It exceeds the permitted level, air-indicator switches off immersion heaters and circulation pump remains active, so that air is allowed to escape easily. Once the air is dispelled the immersion heaters will be active.

3.5. Connection to the electrical mains supply

Before working with the appliance, turn off the power supply (MCB) and secure against restart.

This device must be earthed.

Check that the electrical supply to the building has sufficient current and voltage to supply the boiler and other appliances to be used.

Miniture circuit breakers (MCB) must be fitted in the wiring prior to the boiler. For MCB ratings see table on page 12.

Measure exact voltage between L and N lines prior to connecting boiler, if it 10% higher than nominal voltage on appliance, appliance itself can be damaged.

Connect the boiler to the mains using a double pole linked switch with 3mm contact gap in both poles. There is an RCD switch factory fitted inside the boiler. Supply cables must be connected to the RCD switch inside the boiler as shown below. Stretching force of the network connection is 3,5 Nm.

In order to connect the power supply cable, the power connection protection cover (1) must be removed by unscrewing two screws and pulling the protection cover down. The lower protection cover (4) should also be removed to facilitate access to the wiring points.

The Power cable must be connected directly to the RCD (2), earth must be connected to a separate terminal (3). After connecting the power cable, the protective cover (1) must be replaced and securely fastened.

Upon completion of electrical installation, carry out preliminary safety checks according to BS7671:2001

Note: Power cables from Ø6 mm to Ø20 mm must be connected

from the left side of boiler and the protective cover (see 1 above) must be secured, the power cables in excess of Ø20 mm

Power supply connection

must be connected from the bottom side of the boiler (see 4above) using the provided entry point.

Ensure that the wires are securely fixed.

The appliance must be connected to mains electricity and tested according to current IEE regulations. An NICEIC inspection and completion certificate must be issued.

All exposed pipework must be earthed according to current IEE regulations

Boilers with power 10.8kW and 14.4 kW Boilers with power 4.8, 6, 7.2 kW

RCD connection close-up

Page 18: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 12

3.6. Room thermostat, temperature probes and pumps connection

Removable connectors for room thermostat, pumps and temperature probes are located on connections plate as shown (right). Available connectors are dependent on boiler type and boiler options.

Power supply to control unit:- L - Live feed to external unit N – neutral to external unit PE – earth to external unit 3 – switched live from external unit for DHW 4 – switched live from external unit for space heating

Connections plate

3.6.1. Connect room thermostat/programmer

When connecting the room thermostat, follow thermostat manufacturer’s instructions to connect to Termo boiler.

The boiler is supplied with a fixed link between L and 4. If an external control device (room thermostat and/or programmer)is used, remove this link. The boiler’s terminals 3, 4 and L N PE (power supply for control unit) are for connection to room thermostat/programmer.

3.6.2. Fit external temperature sensor

The external temperature sensor (delivered with boiler) must be fitted in a permanently shaded area to prevent sudden temperature changes through exposure to direct sunlight. When fitting the sensor please observe arrow marking top position (can be seen when protective cover is removed). The sensor is an integral part of the temperature compensation principle and must be fitted as the Plus – E & PTV – E boilers cannot operate correctly without it.

Use twin core cable diameter 0,6mm2 to 1,5 mm2, to connect external temperature sensor,

The boiler is supplied with a factory mounted resistor connected to the outside temperature sensor port that simulates the outside temperature at -13ºC for testing purposes only. After installation and initial testing, the resistor must be removed and wires from the external temperature sensor must be connected to the sensor port. (Circled port on diagram below right).

protective cover

base

External temperature sensor

External temperature sensor connection point on boiler's connection plate

Page 19: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 13

3.6.3. Fitting hot water cylinder temperature sensor (PTV-E only)

The PTV – E has a temperature sensor supplied with the boiler which must be fitted to the domestic hot water cylinder as this ensures a correct reading of the secondary (DHW) temperature.

Use twin core cable of diameter 0.6mm2 to 0.75 mm2. The cable runs from the boiler to the hot water cylinder and the probe should be inserted approximately 30% of the way up the cylinder and at least in the top half of the area covered by a heating coil. The probe must be touching the cylinder wall and held in place using the cylinder insulation. Alternatively a thermostat pocket can be used if available and in the correct position.

Water Cylinder temperature sensor

Water cylinder temperature sensor connection point

on boiler's connection plate

3.6.4. Fitting pump connections and expansion vessel (RS – E only)

Termo RS – E requires expansion vessel and pump(s) to be connected to the heating circuit according to diagram on page 6. Circulation pumps for central heating and hot water should be connected to connections plate according to diagrams in Appendix 1.

Termo Plus and PTV boilers are supplied with pumps and expansion vessel factory fitted and pumps wired to the connections plate.

Page 20: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 14

4. Setting up Boilers

RS - E & Plus - E – Space heating with outdoor temperature compensation

PTV - E – Space heating with Outdoor temperature compensation and domestic hot water

4.1. Control Panel (including fault finding indicators)

1. Display

Default display is of current primary temperature inside the boiler. Temperature range is -19oC (below -19

oC the

display shows - -) up to + 99oC (above +99

oC display blinks).

Following warning signals can be displayed:

� P1 – anti freeze protection for secondary (DHW) is active

� P2 – anti freeze protection for central heating is active

� o1 or c1 – thermal sensor for primary temperature isn't connected or is short-circuited

� o2 or c2 – thermal sensor for external temperature isn't connected or is short-circuited

� o3 or c3 – thermal sensor for secondary (dhw) temperature isn't connected or is short-circuited

2. Led diodes of heater stages in use

LED diodes light to show how many heating elements are active.

3. Led diode OK/air in boiler

If there is no air in the boiler, the diode lights green. If air appears in the boiler, the diode lights red and the boiler shuts down. Upon de-aeration, the diode automatically changes the color to green and operation of the boiler continues.

4. Led diode insufficient supply voltage

Lights red if the net voltage is below 170 V and the boiler shuts down.

5. Led diode for central heating

Indicates the operation of heating circulation pump, provided that the room thermostat is on.

6. Push button to adjust central heating programming.

7. Central heating switch (0 – standby, 1 – on)

Page 21: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 15

8. Push-button to adjust secondary (dhw) programming.

9. Secondary (dhw) switch (0 – standby, 1 – on)

10. Led diode for secondary (dhw), Indicates domestic hot water pump is operating.

11. Water pressure gauge for heating system.

12. Safety thermostat

IMPORTANT: If an error is displayed on the LED display (1) the boiler will stop. If the error is corrected the boiler will automatically continue operation.

If error o3 or c3 occurs, (see 1 above) the boiler will cut out. In this instance it is possible to operate the boiler in central heating mode until the domestic hot water is operational. This can be done by switching off the domestic hot water with switch number 9.

4.2. Choose type of heating (radiator or under floor heating)

Factory default is for radiators. To change to under floor heating, follow instructions below.

1. Disconnect from mains supply

2. Remove front cover of boiler.

3. Remove perspex control panel cover (prize off with screwdriver down channels at either side)

4. Remove control panel, (Push up from bottom and pull out. Pull out whole of panel, there should be no need to disconnect any wires connected to control panel)

5. Remove black plastic shroud at rear of control panel by undoing 2 cross headed screws.

6. Control switches for heating curves are in the position circled in the photograph above.

7. Default setting for radiators is as shown for under floor heating change to

8. Replace black plastic cover. Re-fit control panel. Re-fit panel protector. Re-fit the boiler front cover.

1 42 3

ON

OFF

Function

Pin 1 – ON Set heating type to under floor, curves from 0.1 to 0.9 are active, minimum boiler temperature is set to 15ºC, maximum boiler temperature is set to 45ºC

Pin 1 – OFF

(Factory settings)

Set heating type to radiator, curves from 1 to 3 are active, minimum boiler temperature is set to 25ºC, maximum boiler temperature is set to 90ºC

Pin 2 – ON Disable outdoor temperature compensation, user must manually select temperature in boiler

Pin 2 – OFF

(Factory settings)

Enable outdoor temperature compensation, default curve for radiator heating is 1.5 and 0.6 for under floor heating

Pin 3 Used during manufacturing process

Pin 4 Used during manufacturing process

Page 22: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 16

4.2.1. Hybrid Systems combining radiator and UFH If the boiler is to be used to heat a hybrid system i.e. wet radiator system and under floor heating no alterations should be made to the factory setting. In this situation a blending valve should be fitted in the under floor heating manifold to reduce the flow temperature to maximum 50C.

4.3. Activating system and programming central heating

Off mode - The boiler is connected to the electrical supply but the RCD switch (page 12) is off Standby mode – the RCD switch is on but the central heating on/off and dhw switches on control panel are off On mode – RCD switch, dhw and central heating switch are all on Switch to on mode - Test the RCD switch by pressing T button on it. Reset the RCD switch Operations with Honeywell or Danfoss control units: With central heating programmer (Honeywell ST6400, Danfoss TP-9 7-day programmer or similar) it is possible to program separate periods of central heating from periods for domestic water heating. Switches 7 and 9 on electronic control panel have a different function when 7-day control unit for central heating and sanitary water preparing is installed. In this case position ‘’0’’ is AUTO (operations as controlled by control unit Honeywell/Danfoss) and position ‘’1’’ is MANUAL (operations are controlled by boiler’s control panel). When sanitary water and apartment temperature rises to desired level, boiler automatically goes to standby position (everything is switched of except standby led diode).

Factory defined curves

Sample of modified curve

4.3.1. Heating curves explained. Heating curves take information from the outside temperature sensor and decides on the required primary temperature in the heating system to maintain the desired internal temperature based on the insulation properties of the building.

� The colder it is outside, the higher the temperature needed in the heating system. � Poorly insulated (older) properties require more heat, hence a higher heating curve is selected.

Heating curves save energy. A correctly set curve will optimize savings. A curve set too low will result in a house that feels cooler than desired. A curve set too high will not optimize savings.

Page 23: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 17

Termo E boilers are supplied with a full range of curves to choose from.

The choice of a heating curve is dependent on the insulation levels in the building. Heating curves can be altered at any time by the householder, but once correctly set, should never require adjustment. The best guide to insulation levels is the age of the building, as insulation levels have steadily improved over time. The factory set heating curve is for buildings built to 2000 building regulations and UK heating installation common practice.

The table below shows the suggested heating curves for properties of differing ages. If extra insulation has been retro-fitted to a building, a lower heating curve will be appropriate.

4.3.2. To set correct curve Turn central heating on (key 7).

Press key 6 UP and hold for five seconds to enter curve selection menu. The set curve blinks in the display. Press key 6 up or down to alter curve selection in steps of 0,1, see the diagram on the front plate. If there is no pressure on the key for more than 5 seconds the curve displayed is saved.

Construction date Radiator curve under floor curve Pre 1970 2.0 0.9 1971 – 1990 1.8 0.8 1991 – 1999 1.6 0.7 2000 – 2005 1.5 0.6 2006 1.2 0.5 Factory default 1.5(mod) 0.6(mod)

Factory default curves have been modified specifically for UK heating design standard practice. If curve is altered and default curve is then subsequently required, a factory reset is required. See instructions page 25.

4.3.3. Setting internal temperature

Heating curves are factory set to achieve a 22°C room temperature.

Should the temperature required differ from this, the primary temperature should be raised or lowered (offset) 3°C for every 1°C higher or lower required as room temperature. e.g. if 20°C room temperature is required, the primary temperature should be lowered by 6°C.

Offsetting the heating curve will change the temperature of the water in the boiler without changing the shape of the curve. See diagram above.

To offset the curve. Press key (6) down and hold for 5 seconds to enter offset curve selection menu

The set offset in ˚C blinks in the display. Press key 6 up or down to change offset in steps of 1˚C. If there is no pressure on the key for more than 5s shown value of offset in ˚C is saved.

Factory setting is 0˚C. Offset range is from –9 to +20˚C.

Please note that Thermal (heating) processes are slow, and the impact of alterations will not be felt immediately. Oso recommend that adjustments are given at least 24 hours to take effect.

It is also recommended to make a log of all adjustments made and their result. This will assist in making accurate alterations in the future.

If settings as described above are not adequate for achieving the wanted room temperature, supplemental adjustments of the heating curves and offset can be made by the user. See table below

Conditions experienced Curve selection Offset

(radiator heating) Offset

(UFH heating)

Room temperature is too low if the external temperature is above + 5

oC

Lower curve by 0.1 Add with offset + 6

oC

Add with offset + 4

oC

Room temperature is too low if the external temperature is between + 5

oC and - 5

oC

Leave the curve Add with offset + 3

oC

Add with offset + 2

oC

Room temperature is too low if the external temperature is under - 5

oC

Higher curve by 0.1 Leave offset 0

oC

Leave offset 0

oC

Room temperature is too high if the external temperature is above + 5

oC

Higher curve by 0.1 Lower with offset - 6

oC

Lower with offset - 4

oC

Room temperature is too high if the external temperature is between + 5

oC - 5

oC

Leave the curve Lower with offset - 3

oC

Lower with offset - 2

oC

Room temperature is too high if the external temperature is under- 5

oC

Lower curve by 0.1 Leave offset 0

oC

Leave offset 0

oC

4.3.4. Programmable room thermostats & setting variable internal temperatures

Central heating is controlled by the heating curve programmed into the Termo E boiler and fine tuned by a room thermostat.

With modern central heating controls such as a programmable room thermostat it is possible to set different room temperatures at different times of the day. e.g. to have a lower temperature set during the night. If this system is used the heating curve selection is unchanged and the offset of the heating curve should be set to the highest room temperature required during the day. (See paragraph above). The programmable room thermostat is then set according to the manufacturers instructions to set lower temperatures when required.

Page 24: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 18

When setting variable temperatures please be aware that the heating system will take some time to heat up from cold and similarly will remain hot for some time after the temperatures are reduced or the system is switched off. To optimize comfort levels and minimize energy consumption it is suggested to activate the boiler 30 minutes before the set temperature in heating system is required and to reduce temperature or switch off 30 minutes before the lower temperature is desired.

5.4. Domestic hot water priority

Domestic water heating has priority over central heating. When the domestic hot water temperature sensor calls for heat, the central heating circulation pump is switched off and domestic hot water heating circulation pump is switched on.

The setting of secondary (DHW) temperature regulates the desired primary temperature in the boiler. The primary water is set at 15°C higher than the desired secondary (DHW) temperature. (Independent of central heating curve).

The boiler heats the cylinder until the desired secondary (DHW) temperature is reached, the elements will then power down and the pump overrun operates - see page 24.

If the central heating is on, when the desired secondary (DHW) temperature is reached, the desired primary temperature reverts to the value from the heating curve.

If the central heating is off, when desired secondary (DHW) temperature is reached, the desired primary temperature reverts to the stand-by value of primary water temperature in the boiler.

If the cylinder probe repeatedly calls for domestic hot water heating, the desired water temperature in the boiler is automatically set to 15°C higher than the desired secondary (DHW) temperature.

There is a 5°C difference between switch on and switch off for secondary (DHW) heating. If the desired temperature of hot water cylinder is 60°C, the domestic hot water is activated only when the cylinder store temperature cools to 55°C. Domestic hot water heating is switched on until the hot water temperature reaches 60°C.

During periods of simultaneous demand for space heating and domestic water heating, the boiler will alternate between the two every 30 minutes.

4.5. Protection from freezing

4.5.1. Domestic hot water If the boiler is on, protection from freezing of the domestic hot water cylinder switches on automatically when the cylinder temperature reads a value below 5°C, signaling switching on by blinking display, as well as the LED diode of the heater and water heating, regulating the cylinder temperature to 5°C.

4.5.2. Central heating

To protect the entire central heating system from freezing (if a building is to be left empty for an extended period of time during cold weather), set the boiler to standby mode. The room thermostat or central heating programmer must be set to freezing protection mode (usually 5 to 7˚C, depending from room thermostat manufacturer), this will allow pump to circulate heated medium through central heating system.

Page 25: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 19

5. Recommended annual checks (all boilers) The safety valve should be checked annually, preferably before the heating season to ensure correct operation and avoid accumulation of lime scale. It is not recommended to annually drain the system to protect the system from freezing as refilling with fresh water will increase the risk of limescale attack

We recommend inspection of the boiler once a year by an authorized service engineer. This service is not included in the guarantee. During the inspection all electric and water connections should be tightened, the system should be vented and – if necessary – filled up, valves and general functionality of the device and safety valves should be checked.

When cleaning the product do not use an aggressive liquid as e.g. gasoline, kerosene or solvent. For the external shell and decorative cover, liquid for cleaning plastics or dish washing media may be used. Control panel should be cleaned with dry or moist cloth (not wet).

Page 26: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 20

6. Central heating controls advanced menu. Please note that the following information provides full details on the options available for Termo boilers. In most installations the factory settings do not require alteration. Instructions necessary for standard installations are slanted. Instructions necessary only for advanced programming are underscored. Please note that keys 6 and 8 have a rocker action and operate as directed below by up or down pressure

Display of actual primary temperature inside boiler.

Default display is of actual primary temperature inside boiler.

Display of desired primary temperature inside boiler

Press key (6) up and release to see desired primary temperature inside boiler. (Calculated from selected heating curve)

The Display shows the desired temperature of primary water in the boiler. The value is shown for 5 s, after which display reverts to show actual temperature of primary water in the boiler.

Heating curve selection (ensure correct choice of radiator or underfloor curves – see part 3.5.2 page 12)

Press key (6) up and hold for 5 seconds to enter curve selection menu.

The display blinks showing current curve setting

Values range between 1 and 3 or 0,2 and 0,8. Curves between 1 and 3 are for radiators’ central heating and curves 0,2 to 0,8 are for under floor heating.

Press the key up or down, to alter curve selection in steps of 0,1, according to the diagram on the front plate. If there is no pressure on the key for more than 5 seconds the curve displayed is saved.

Limiting maximum power of boiler (manually deactivating 1 or more immersion elements).

Press key (6) up and hold for 10 seconds to limit power level.

By pressing the key up and down it is possible to select 1 2 or 3 as number of available power levels (immersion heaters). If there is no pressure on key (6) for more then 5 sec. selected power level mode is saved.

Boilers from 6 to 16 kW have only two power levels.

Limiting maximum primary temperature inside boiler (max possible is 90°C for radiator heating and 50°C for under-floor heating)

Press key (6) up and hold for 15 seconds to limit maximum primary temperature inside boiler.

Factory defined maximum primary temperature starts to blink, by pressing key (6) up or down user can set new maximum primary temperature. If there is no pressure on key (6) for more then 5 sec. selected maximum primary temperature is saved.

This temperature represent temperature maximum that can be achieved regardless of selected curve.

Manual selection of desired primary temperature inside boiler

>5 sec0.6

41>5 sec

>10 sec

>5 sec 3

32

>5 sec

<5 sec

>15 sec

>5 sec 90

>20 sec 60 32

>5 sec

Press key (6) up and hold for 20 seconds to set primary temperature in boiler, regardless of previously selected curve.

Desired primary temperature starts to blink. By pressing key (6) up or down user can select fixed primary temperature in boiler. If there is no pressure on key (6) for more then 5 sec. fixed primary temperature is saved.

When boiler is in fixed primary temperature mode, LED display blinks while displaying current primary temperature in boiler. For next change of fixed temperature, user can just press key (6) up or down.

When boiler is in fixed primary temperature mode, all heating curves are disregarded. To return to heating curve mode, boiler must be switch OFF and back ON using ON/OFF switch.

Page 27: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 21

Continuation...

Display of external temperature

Press key (6) down and release to see external temperature.

The Display shows the external temperature. The value is shown for 5 s, after which display reverts to show actual temperature of water in the boiler.

Offset of currently selected heating curve (see part 3.5.3 page 13)

Press key (6) down and hold for 5 seconds to enter offset curve selection menu

LED display will show current offset in ˚C. Offset doesn’t affect maximal or minimal temperature, they are set in absolute values

By pressing the key (6) up or down it is possible to change offset in steps of 1˚C.

Factory setting is 0˚C.

Offset range is from –9 to +20˚C.

If there is no pressure on the key for more than 5s shown value of offset in ˚C is saved.

Setting the minimum primary temperature inside boiler

Press key (6) down and hold for 10 seconds to select minimum primary temperature inside boiler.

Minimum primary temperature starts to blink.

Factory setting is 45°C for radiator heating.

Factory setting is 30°C for under floor heating.

By pressing the key up or down user can select desired primary temperature in range from 10 to 50°C. Temperature changes in 1°C steps. If there is no pressure on the key for more than 5s the value from the display is saved as the desired minimum primary temperature.

Displaying software version and factory reset

>5 sec 0

-1>5 sec

>10 sec

>5 sec20

32

>5 sec

<5 sec

>15 sec1.4

Press key (6) down and hold for 15 seconds, LED will show software version and factory reset of central heating parameters will occur.

Page 28: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 22

6.1. Domestic hot water advanced menu (control panel type 2)

Display of desired secondary (DHW) temperature

Press the key (8) up and release, LED display will show desired secondary (DHW) temperature. The value is shown for 5 s, after which display reverts to actual temperature of primary water in the boiler.

Setting desired secondary (DHW) temperature

Press key (8) up and hold for more than 5 seconds to set secondary (DHW) temperature.

The desired secondary (DHW) temperature blinks.

By pressing the key (8) up or down the value of desired secondary (DHW) temperature in the storage cylinder changes in 1°C steps. If there is no pressure on the key for more than 5s the value from the display is saved as the desired secondary (DHW) temperature.

Possible adjustment from 10°C up to 65°C.

Factory default is 50°C.

Displaying software version and factory reset

>5 sec50

50>5 sec

>10 sec

32

>5 sec

<5 sec

1.4

Press key (8) up and hold for longer than 15 sec, LED will show software version and factory reset of central heating parameters will occur.

Page 29: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 23

Continuation...

Display of current secondary (DHW) temperature

Press key (8) down once and release to display current secondary (DHW) temperature. The value is shown for 5 s, after which display reverts to actual primary temperature in the boiler.

Setting pump overrun for secondary (DHW) water

Press key (8) down and hold for 5 seconds to set pump overrun of secondary (DHW) water

The time for secondary (DHW) pump overrun blinks.

Press key (8) up and down to change time from 0.1 min up to 1.9 min. with the step of 1 digit. If there is no pressure on the key for more than 5s, the value from a display is saved as time for secondary (DHW) pump overrun.

Factory default overrun is 1 min.

Setting stand by primary temperature inside boiler

Press the key (8) down and hold for 10 seconds to set stand by primary temperature inside boiler.

LED display will show current stand by primary temperature inside boiler.

Press key (8) up or down to change stand by temperature in range from 10°C to 50°C , by 1°C. If there is no pressure on the key for more than 5s, the value from a display is saved as stand by primary temperature inside boiler.

Displaying software version and factory reset

>5 sec1.0

36>5 sec

>10 sec

>5 sec20

32

>5 sec

<5 sec

>15 sec1.4

Press the key (8) down and hold for 15 sec, LED will show software version and factory reset of central heating parameters will occur.

Page 30: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 24

7. Fault finding guide

The boiler is notoperating or radiators

are cold

Is the boilerswitched ON?

Switch boiler ON

NO

Is the greenLED lightON?

YES

Are the MCB (on master switch board) and RCD

(in boiler and master switch board) switched ON?

NO

Switch ON MCB

NO

Switch ON RCDRCD can't beswitched ON

YES

YES

Reset safety thermostatand try again to switch

RCD ON

NO

Electrical part of boiler(heater, switch, relay)

is faulty

DoesDISPLAY

show temperatureinside boiler?

NO

NO

YES

Is the temperature of water

same asdesired?

YES

Wait for boiler to heat upNO

Is the roomthermostat switched

ON?

YES

Switch ON roomthermostat

Check isolation valves

NO

YES

Faulty control panelNO

Please check the following before going through fault finding flowchart.

Check the installation is correct. All isolating valves are open. The system is full of water (pressurised) and purged of air. Programmer and controls outside of boiler are on. Check the electrical supply is connected correctly and present

YES

One or more heaters are faulty

Page 31: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 25

When switched on,switches on control

panel show thevoltage, however the boiler does not heat

Is thelimiting thermostat

activated?

Safety thermostat can beactivated if air is present in

installation or operation thermostatis faulty or relay is blocked

Is the roomthermostattoo low?

YES

YES

Is theoperating thermostat

defective?

NO

NO

Replace the operating thermostat with new

YES

Please check the following before going through fault finding flowchart.

Check the installation is correct. All isolating valves are open. The system is full of water (pressurised) and purged of air. Programmer and controls outside of boiler are on. Check the electrical supply is connected correctly and present

NO

Adjust correct temperature

Is the RED lamp

''air in the boiler''illuminated?

Check the water pressure and purged of air

YES

NO

Is thevoltage presenton immersion

heaters

Replace the immersionheaters

YES

Page 32: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 26

Boiler ''roars'' while heating

Check the water pressure and vent thecentral heating

system

Defective immersion heaters- change the heaters

YES

Please check the following before going through fault finding chart: Check the installation is correct. All isolating valves are open. The system is full of water (pressurised) and purged of air. Programmer and controls outside of boiler are on. Check the electrical supply is connected correctly and present

Central heatingsystem was notvented properly

Lower the speed oncentral heating pump(see guide below)

YES

NO

Changing the speed of pump for central heating For Termo Blok and Termo Blok PTV, open the cover of boiler as described in chapter 4.4. and locate central heating pump, use chapter 2.4. for assistance. Move speed slider (1) to desired mark. For Termo Extra boilers external pump is fitted, consult pump manuals for guidance.

Selecting pump speed

Page 33: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 27

Central heating isworking but domestic

hot water (DHW)is not working

Is the relay RHWin ON possition?

Is the votage present on DHW pump therminals?

NO

YES

NO

Please check the following before going through Fault finding chart.

Check the installation is correct. All isolating valves are open. The system is full of water (pressurised) and purged of air. Programmer and controls outside of boiler are on. Check the electrical supply is connected correctly and present

YES

Find and restore break of connection

Are the parameters for DHW on

control panel or/and externalprogrammercorrect?

Change parameters

NO

YES

Check externalprogrammer

NO

Change the relay RHW

YES

Change the DHW pump

Is the voltage present on terminals

a1(L) and a2(N) of relay RHW?

Page 34: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 28

Domestic hot water isworking but

central heatingis not working

Is the relay RCHin ON possition?

Is the votage present on CH

pump therminals?

NO

YES

NO

Please check the following before going through Fault finding chart.

Check the installation is correct. All isolating valves are open. The system is full of water (pressurised) and purged of air. Programmer and controls outside of boiler are on. Check the electrical supply is connected correctly and present

YES

Find and restore break of connection

Are the parameters for central heating on

control panel or/and externalprogrammercorrect?

Change parameters

NO

YES

Check externalprogrammer / room

thermostat

NO

Change the relay RCH

YES

Change the CH pump

Is the voltage present on terminals

a1(L) and a2(N) of relay RCH?

Page 35: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 29

RCCB switch cannotbe switched ON

Check existanceof resistance

between terminals N,3,5,7or RCCB switch and PE

Find component which hascontact between earth (PE) and

change it.

YES

Please check the following before going through Fault finding chart.

Check the installation is correct. All isolating valves are open. The system is full of water (pressurised) and purged of air. Programmer and controls outside of boiler are on. Check the electrical supply is connected correctly and presentCheck the

status of safety thermostat, try to

reset it

Switch on RCCB switch

YES

NO

Change the RCCB switch

NO

Page 36: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 30

8. After Sales service information If after using the fault-finding guide above the problem cannot be rectified by the installation engineer on site, a qualified Oso Service Engineer is available during normal office hours to attend a breakdown.

A charge will be made if:

There is not a fault with the Termo boiler or the breakdown was caused by incorrect installation of the product that does not conform to the installation manual.

Components fitted on the system that were not supplied by Oso are preventing the satisfactory operation of the Termo boiler.

The terms and conditions of the guarantee have not been satisfied or the warranty period of the Termo boiler has expired.

Many boiler manufacturers find that a very large proportion of service calls are not caused by a product fault. Please read the fault finding guide and the other instructions in this manual carefully.

Oso will not accept unauthorized invoices from any third party for repair or service work to Termo boilers.

9. Cascade power limiter Where there are other high load electrical appliances e.g. electric ovens, electric showers etc fitted in the property with the boiler there is a possibility of overload on the electrical system. The Oso cascade power limiter is a unique device that continually monitors the electricity consumption of the property and if required will power down the boiler temporarily to prevent overload.

10. OSO Hotwater UK Ltd Oso Hotwater UK Ltd E15, Marquis Court Team Valley Tarding Estate, Gateshead Tyne & Wear NE11 0RU

Tel: 0191 482 0800 Fax: 0191 491 3655 www.oso-hotwater.com [email protected] [email protected] [email protected]

11. Appendices Appendices with further technical information are displayed on the following pages, These appendices should be used in conjunction with the information supplied elsewhere in the manual and show additional schematic and electrical diagrams to assist in the installation of Termo boilers into different central heating systems. Advice is given for a variety of standard systems commonly used in the UK, however the list is not exhaustive and OSO Hotwater UK Ltd cannot guarantee that the advice will be correct for any particular system.

All diagrams are shown for informational purposes only. Diagrams are not comprehensive and do not show every system detail.

Page 37: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 31

11.1. Appendix 1 - Termo RS with space heating and water heating

11.1.1. Schematic diagram Termo RS - E

11.1.2. Wiring diagram Termo RS - E

Page 38: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 32

11.1.3. S-Plan wiring layout Termo RS -E

Page 39: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 33

11.2. Appendix 2 - Termo RS – Space heating only

11.2.1. Schematic diagram Termo RS - E

11.2.2. Wiring diagram Termo RS-E

Page 40: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 34

11.2.3. S-Plan wiring layout Termo RS-E

Page 41: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 35

11.3. Appendix 3 - Termo PLUS E

11.3.1. Schematic diagram Termo plus-E

REMARK: this scheme is for informational purposes only, not all details necessary for installation are shown

BASIC USAGE SAMPLE FOR CENTRAL HEATING

With Termo Plus – E electric boiler up to 14.4kw N-50/60Hz and up to 36 kw 415V 3 N-50/60Hz

BASIC USAGE SAMPLE FOR CENTRAL HEATING

With Termo Plus – E electric boiler up to 14.4kw N-50/60Hz and up to 36 kw 415V 3 N-50/60Hz

11.3.2. Wiring diagram Termo plus-E

Page 42: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 36

11.3.3. S-Plan wiring layout

11.4. Appendix 4 Termo PTV E

11.4.1. Schematic diagram Termo PTV-E

11.4.2. Wiring diagram Termo PTV-E

Page 43: TERMO ELECTRIC BOILERS - jhplumb.com · The company reserve the right to alter size, shape and specification without prior notice Page 1 2. Termo E range 2.1. Key to TERMO boilers

The company reserve the right to alter size, shape and specification without prior notice

Page 37

11.4.3. S- Plan wiring layout Termo PTV-E